WIP210 Panel  www.videofied.comDoc. - Ref.   230-WIP210Last modification date : February 2015Firmware version : XLP 05.21.03.XXX and laterINSTALLATION MANUALW and WIP Panel
2W and WIP Panel www.videofied.comDescription  Since 2002, RSI VIDEO TECHNOLOGIES provides the only wireless video verification on the market, thanks to the Motion Viewer™ detectors and to the Videofied®product rangeAfter 2 years of development, RSI VIDEO TECHNOLOGIES is proud to present the new W alarm panel.The W alarm panel is wireless and mains powered with a backup rechargeable battery (provided). The W panel is the first Videofied® alarm panel that can be used as a connected device.This panel is intended for residential and commercial markets.Like all the Videofied® alarm panels, the W panel is compatible with every radio device manufactured by RSI VIDEO TECHNOLOGIES. TechnologyThe W alarm panel uses the S2View® patented technology. That interactive and wireless technology ensures signal integrity. The bidirectional radio link maximizes the signal reliability.AES encryption protects the communication between the panel and the devices. Transmission security is optimal.  The jamming detection feature identifies any intentional jamming from a third party. The supervision feature consists of transmitting signals between every device of the system and the W alarm panel. Through the supervision, the detectors transmit every 8 minutes a presence signal.The entire RSI VIDEO TECHNOLOGIES team wishes you a successful installation.Introduction INSTALLATION MANUAL
3W and WIP Panel www.videofied.comIntroduction................................................................................................2Summary..............................................................................................31.  W installation and setup...............................................................................41.1 Panel overview......................................................................................................41.2 Panel mounting......................................................................................................41.3 Ethernet cable connexion......................................................................................51.4 SIM card installation.............................................................................................51.5 Powering and initialization....................................................................................51.6 Indicator lights.....................................................................................................61.7 Pairing the keypad...............................................................................................62. W panel programming...........................................................................................7ETHERNET parameters configuration...........................................................................113. W panel features guide......................................................................................153.1 Get to access level 4.........................................................................................153.2 How to arm/disarm the system.............................................................................153.3 Arming and siren mode configuration..................................................................163.4 Manage badges and access codes........................................................................173.5 Delete the keypad................................................................................................193.6 Read the event log.............................................................................................203.7 Golden rules.........................................................................................................204. Ethernet parameters..............................................................................................215. Transmitter events list.........................................................................................226. 2G3G error codes................................................................................................237. Security and certifications notes.......................................................................248. Technical specifications.....................................................................................26Summary INSTALLATION MANUAL
4W and WIP Panel www.videofied.com1. W installation and setup1.1 Panel overviewSIM card installationEthernet cable connectionStatus LEDsMini-USB connector for power supplyBattery connector1.2 Panel mountingFix the back casing on the wall using the three mounting holes (4 mm diameter) as shown.Mounting the panel is not required for programming.Bracket holesWIS100Siren connectorCOM button INIT button Locking screwsINSTALLATION MANUAL
5W and WIP Panel www.videofied.com1. W installation and setup1.4 SIM Card InstallationInsert a Mini-SIM 2FF SIM card in the location shown in the image.  Please refer to the markings for the insertion direction.Use a M2M (machine-to-machine) 2G3G SIM card. If the panel is used with a smartphone application, the SIM card shall be able to receive SMS.DO NOT insert or remove the SIM card while the panel is powered.1.5 Powering and initializationAC Power•  Connect the backup battery.•  Install the power supply inside or outside the panel box depending on the needed cable length.•  Connect the power supply to the panel mini-USB connector•  Plug the power supply in an electrical outlet.Initialization•  Leave the panel open. The green status LED de statut verte is on. Press and hold the INIT button for 6-7 seconds until the status LED turns red for 1 second.•  The red LED blinks several times then turns off. That procedure resets the panel memory.•  The panel is now reset, a Videofied® keypad has to be enrolled to configure the panel.1.3 Ethernet cable connectionOnce the panel is fixed on the wall connect a RJ45 cable between the site internet network and the panel Ethernet port.When the panel attempts a transmission via Ethernet, a red LED on the connector will flash. This will allow the installer to check whether the panel is connected to a valid network.Do not touch the RJ45 cable when the panel is powered.IMPORTANT :Only connect the panel on 10Base-T SELV networks.Only for models WIP 210/220/230, WIP 620/630 and WIP 720/730INSTALLATION MANUAL
6W and WIP Panel www.videofied.com1. W installation and setup1.6 Pairing the remote keypad•  Press briefly the panel INIT button and release for the enrollment of a programming keypad.•  Insert 3 or 4 LS14500 Lithium batteries into the keypad.•  Do not mount the keypad. It will display on of the following screens:RSI (c) 2015videofied.com <=========XX=========>or•  Press on both CLR and ESC NO keys at the same time and release. The indicator LED on the keypad will blink rapidly. Wait for the keypad to pair.•  If the keypad does not pair up with the panel and shows “XX”, it certainly means that it is stilled paired to another system. The keypad needs to be reset. Remove the batteries and press repeatedly on the keypad tamper switch for 30 seconds to 1 minute. Then proceed to the above steps.1.6 Indicator lightsRed LED on Red LED blinking (every 3 seconds) Red LED offGreen LED on (AC power detected)Battery out of order or not detected.Low voltage on the battery. Normal operationGreen LED off(AC power not detected) Low voltage on the battery. Panel working on battery. Battery OK.Panel not powered or out of order.INSTALLATION MANUAL
7W and WIP Panel www.videofied.com2. W panel programmingUse the keypad to program the panelKeypad Display Actions and commentsKEYPAD 1RECORDEDRADIO RANGE TEST?RF TESTx/9RF TEST9/9RADIO RANGE TEST?INSTALLER CODE4 TO 6 DIGITS THEN OK/YESINSTALLER CODE:< - LANGUAGE :  - >ENGLISH (UK)The system can also be programmed in : french, italian, german, dutch, spanish, swedish, portuguese, danish, czech, turkish and polish.The language can be changed at any time once the panel is programmed in the MAINTENANCE menu.The radio range test must be run during the device learning process in order to ensure proper pairing with the control panel. This test is important, it measures the strength of communication between the device and the control panel. The keypad will display a real time radio range value on a scale of 9.To receive the most accurate results you must run the radio range test for at least 30 seconds.Result must be 8 out of 9 or better for reliable transmission.OK or YESOK or YESAttendreOK or YESESCNOfor language selectionOK or YESCONFIRM CODEOK or YESOK or YESUsing the alphanumeric keypad, enter the installer code of your choice.The installer code will be used for all future maintenance and configuration.This code is important to keep track of. There is no back door or Default codes to the system.Please refer to the restriction rules for codes (Chapter 3.4). Some codes are already used by default and therefore cannot be used.INSTALLATION MANUAL
8W and WIP Panel www.videofied.com2. W panel programmingYou may name the installer code using the alphanumeric keypad.If using automatic setting (called installer default list), enter the name of the list.Warning : If the wrong installer list name is used, it cannot be set later, the system must be defaulted.Leaving the name blank by pressing ESC NO, it will be named ‘ACCESS 1’ by default.Use the alphanumeric keypad to enter in a 4-8 digit account number provided by the Central StationCODE NAME : OK or YESACCESS 1REGISTEREDWaitADJUSTING DATE AND TIMEDATE (YEAR):15/ /To set the yearOK or YESDATE (MONTH):15/01/To set the monthOK or YESYou may proceed in the same way for : Day, Hour and Minutes15/01/19 10:47ENTRY COMPLETE !CONNECTED TO MONITOR. STATION?ACCOUNT NUMBER :OK or YESACCOUNT NUMBER :567001OK or YESPERIODIC TESTPERIODIC TEST :   24 HOURSTo select periodicityOK or YESTest Periodicity: 1 hour, 12 hours, 24 hours, 48 hours, 7 days or no tests.We suggest a 24 hours periodic test call.ESCNOINSTALLATION MANUAL
9W and WIP Panel www.videofied.com2. W panel programmingTEST (hour) :04:CODE / TEST   MODIFICATION?OK or YESTEST (minutes) :04:15OK or YESOK or YESThe CODE/STATE MODIF. menu is used to configure the transmitted events to the monitoring station. Use the arrow keys to toggle between events and OK or YES to modify.ALARM: event transmitted upon occurrence.ALARM/END: event is transmitted on occurrence and on event restoral.NOT TRANSMITTED: event is not transmitted, however it will appear on the keypad.Please liaise with your Monitoring Station to ensure that the requested events to transmit are correctly set.CODE / TEST   MODIFICATIONEvents listESCNOSERVERADRESSES ?OK or YESWaitADRESSES SERVEUR ?IP1 ADDRESS0.0.0.0DOMAIN NAME 1 PORT 1888The  IP1 address,  Domain Name 1 and/or Port 1 are provided by the monitoring station. Leave Port details at 888 unless otherwise instructed.Press OK or YES to enter/modify the parameter then OK or YES for validation.WARNING : You will use either an IP address or a Domain name, but not both, leave the Domain name blank if an IP address has already been entered.Press on the right arrow to configure IP/Domain name 2 and PORT2 (for the back-up server), and IP/Domain name TMT and PORT TMT (to configure remote maintenance server).ESCNOESCNOSTR ATEGY:ETH+2G3GOK or YESESCNOThe panel transmits in priority to IP1 (or DOMAIN NAME 1) / PORT 1 then to IP2 (or DOMAIN NAME 2) / PORT 2 as a backup.INSTALLATION MANUAL
10W and WIP Panel www.videofied.com2. W panel programmingSTR ATEGY:ETH+2G3G How the alarms and videos are transmitted to the monitoring station : 2G3G :     SIM card transmission onlyETH :    Ethernet transmission only (not recommended***)WLAN :    Wi-Fi** transmission only (not recommended***)ETH+2G3G :    Ethernet* transmission with backup SIM card2G3G+WLAN :    Wi-Fi** transmission with backup SIM cardETH+WLAN :    Ethernet* transmission with backup Wi-Fi** (not recommended***)ETH+2G3G+WLAN :  Ethernet* transmission with backup Wi-Fi** then backup SIM card*Only for models WIP 210/220/230, WIP 620/630 and WIP 720/730**Only available when the WWB100 module is installed.***In case of internet loss or AC power loss, transmission failures can occur by using Wi-Fi and/or Ethernet without a 2G3G line backup. OK or YESAPN CODE USER NAME PASSWORDThe APN Code (Access Point Name), User Name and Password are supplied by the mobile operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator.Press OK or YES to enter/modify the parameter then OK or YES for validation.Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! It makes a difference between UPPER and lower case letters.To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key (0-9) for XMA/XMB.ESCNO2G3GPARAMETERS ?2G3G LEVEL ?2G3GPARAMETERS ?OK or YESESCNOESCNOOK or YESTEST IN PROGRESSEND = OK/YES2G3G LEVEL5/5 2G3G2G3G LEVEL ?OK or YESOnce the 2G3G test completed, the keypad will display one of the following results :- A level between 0/5 and 5/5.- A GPRS Error code (please see Chapter 6 : 2G3G errors codes and contact your technical support).If the screens shuts down, press any key to light it up except OK or YES, ESC NO or CLR.The 2G3G level test can last several minutes.  Do not interrupt the test or remove the SIM card during the test.IMPORTANT : Videofied will require a 3/5 grade or better for reliable transmission of Video alarms.INSTALLATION MANUAL
11W and WIP Panel www.videofied.com2. W panel programmingIPPARAMETERS ?OK or YESETHERNET parameters configurationDHCP :ENABLED PANEL IPDHCP :DISABLEDOK or YESIP MASKGATEWAYPRIMARYDNSSECONDARYDNSIPPARAMETERS ?ESCNOETH. STATUS ?TEST IN PROGRESSOK/YES = ENDESCNOOK or YESPANEL IPXXX.XXX.XXX.XXXETH. STATUS ?ESCNOESCNODuring this test, the panel tries to connect to the local Ethernet Network. The result of this test can be:•  If the connection is successful:  the local IP of the panel will be displayed (you can display other Ethernet parameters with the arrows            ).•  ETHERNET OFF NO STATUS : the Ethernet module is switched off. Please verify that the Ethernet cable is connected and try again..•  NETWORK/CABLE MISSING :  the panel doesn’t detect Ethernet Cable or NetworkBy setting the DHCP as ENABLED, a new IP address will be assigned dynamically to the panel every time it connects to the network.Network parameters will not be asked.If the router forces a static IP address for the panel, there will then be a need to define DHCP as DISABLED. You will then need to fill in the following network parameters fields : Panel IP, IP Mask, Primary DNS, Gateway and Secondary DNSWarning: Verify that the IP address selected is available on the Network and accepted by the router.ESCNOOnly for models WIP 210/220/230, WIP 620/630 and WIP 720/730INSTALLATION MANUAL
12W and WIP Panel www.videofied.com2. W panel programmingFor full compatibility with EN50131 norms, press  OK or YES. Otherwise, press  ESC NO.COMPATIBILITYEN 50131 NORMS ?AREAS CONFIGURATIONAREA 1 NAME :Press ESC NO to default the area names.Enter the name of Area 1 and confirm with OK or YES.Repeat the procedure for areas 2,3 and 4. For further details, please refer to chapter 3.3.ESCNOOK or YESOK or YESOK or YESEXIT DELAY :45 secFor the selectionOK or YESAvailable delays are : 2 min, 1 min, 45 sec.ENTRY DELAY :15 secAvailable delays are : 15 seconds, 30 seconds, 45 seconds, 1 minute et 2 minutes.For the selectionOK or YESPRESS PROGRAM BUTTON OF DEVICERECORDINGDEVICES Each device has a unique programming button or a specific manipulation. Please refer to the Installation Sheet for the device you would like to program.DEVICE RECORDEDOK or YESRADIO RANGE TEST?RF TESTx/9RF TEST9/9OK or YESAttendrePlease check the radio level of each device on its final location. The result must be 8 out of 9 as a minimum.Please refer to the RF test section on page 6 for further details.INSTALLATION MANUAL
13W and WIP Panel www.videofied.com2. W panel programmingRADIO RANGE TEST?OK or YESESCNOAREA ALLOCATION :AREA 1To select the device areaOK or YESNAME + LOCATION :OK or YESFUNCTIONALDEVICE TEST ?TEST IN PROGRESSEND = OK/YESOK or YESOK or YESEach device is recorded in an area. Each area can be configured as delayed or immediate. Areas are used to set up special arming modes as well.Please refer to the chapter 3.3 for further details about special arming modes.By default (area set as Automatic), area 1 is delayed whereas areas 2, 3 and 4 are immediate. Recording a keypad or a badge reader in an area will automatically delay that area.The name of the device shall contain every needed information to be properly processed in case of alarm.During the functional device test, the device LED turns on when it detects an intrusion.ENTERING A NEW DEVICE ?ESCNOPress OK or YES to enter another device or ESC NO to move on to the next step.Each system can embrace a maximum of 25 devices, programming keypad included.RF TEST9/9BADGE ENTERED ?RECORDING A NEW BADGE ?END OF CONFIGURATIONESCNOESCNOPress OK or YES if you use one or more badges. ESC NO if you are not using any badges.These badges will be used as a first user access (Level 3) and will be mandatory to access the engineer level (Level 4).If you wish to use an user code, please skip this step and when initial programming is completed go to the BADGES/ACCESS CODES menu (please refer to chapter 3.4 for further details).Badges and codes are limited to 49 user accesses and 1 engineer code.OK or YESINSTALLATION MANUAL
14W and WIP Panel www.videofied.com2. W panel programmingWhen the configuration is over, close the panel box as shown below and lock the panel. You can find screws to lock the panel inside the box (see chapter 1.1 on page 4). Then stick the provided tag to seal the panel.Box locking and sealing is mandatory to comply with NF&A2P and EN50131 standards.OPERATIONCOMPLETED?SYSTEM CHECK IN PROGRESSINSTALLATION SUCCESSFUL !Before completing programming make sure that no device is tampered. Each device must be closed and its LED indicator shall be turned off.Aer initial programming has been completed, make use of the menu overview document (available on our technical support portal), to see full programming options.OK or YESThe keypad displays : Locking screws locationSealing tagINSTALLATION MANUAL
15W and WIP Panel www.videofied.com3. W panel features guide3.1 Get to Access level 4Tue 29/10    11:23DISARMED LVL:1ACCESS LEVEL1ACCESS LEVELLEVEL : 1ACCESS LEVELLEVEL : 4OK or YESOK or YESTo unlock and get access to the installer level 4, you need to successively enter TWO codes (in any order) :•  INSTALLER CODE (entered during intial programming)•  USER CODE (Level3): the user must authorize the installer to get access to the configuration of his panel.OK or YESBADGE OR CODE3.2 How to Arm/Disarm the SystemWhen in standby mode, the system can be armed with the remote keypad , the remote keyfob and/or the remote badge reader.Full arming with personal code Full arming with badge Special Arming 1 Special Arming 2With remote keypadEnter your user code and press OK or YESPresent your badge on the keypad( XMB model only)Pressenter your user code and press OK or YESPressenter your user code and press OK or YESWith remote badge reader BR250N/A Present your badge on the badge reader  N/A N/AWith remote keyfobN/A N/A                Press                PressINSTALLATION MANUAL
16W and WIP Panel www.videofied.com3. W panel features guide3.3 Arming and Siren Mode Configuration• Use                   to go to menu :CONFIGURATION (LEVEL 4) > SPECIAL ARMING MODES > FULL ARM, SP1 or SP2 • There are 3 different arming modes :FULL ARM :  Arming of all areas and all devices. Use a badge or a user code and press OK  /               .SP1 : Partial Arming (1) is enabled by entering the user code and pressing                 on the keypad or             on the keyfob.SP2 : Partial Arming (2) is enabled by pressing                   and entering the user code. On the keyfob, SP2 is enabled by pressing           .For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm.  Areas :  1  2  3  4  Each time you press the corresponding number, the system will toggle the arming              state for the respective area.State :  A A A A  Press  OK / YES  aer this configuration step. The system will then display what siren              mode will be in effect for this special profile.  Select the siren mode using the direction         arrows then press OK / YES. A  ArmedDDisarmedPPerimeter(by default : all opening contacts*)EExternal (by default : all opening contacts with external access*)* You can set your devices as : External, Perimeter, ou External +Perimeter. Please go to the menu:CONFIGURATION (LVL 4) > AREAS AND DEVICES > DEVICES > DEVICES CONFIGURATION > DEVICE TYPESiren Immediate triggering of all sirensDelay Beeps Entry/Exit delay beeps, then triggering of all sirensSilent No Sirens, No BeepsWithout Siren Beeps on the keypad onlyINSTALLATION MANUAL
17W and WIP Panel www.videofied.com3. W panel features guide3.4 Manage badges and access codesCodes and badges get rights access to one of the 4 available levels of access.Access Level Definition & RightsLVL 1 Standby LevelLVL 2Restricted USER level, where it is only possible to arm/disarm the system.LVL 3USER level, where it is possible to arm/disarm the system, check the event log, test the devices.Modifications of the settings are not possible at this level.User Level 3 can create Level 2 or Level 3 access codes or badges. LVL 4INSTALLER level, where it is possible to modify the setup of the panel. . To access Level 4, the approval of a Level 3 oe Level 2 user is required. Installer Level 4 can creat the first Level 3 access code only. How to return to the LVL1?   •  Aer 1 min of no use of the keypad and no tests running, the display returns to the standby display and LVL1.    •  When standby display, if the  ESC NO key is held during 5s, the level is changed to LVL1.Access LevelINSTALLATION MANUAL
18W and WIP Panel www.videofied.com3. W panel features guideWhen a code is created (1000 for example), the 2 next codes and previous codes (0998, 0999, 1001 and 1002) will be automatically reserved.The  +1 code (1001) is used for disarming under duress. The +2 code (1002) is used for panic. The -1 and -2 codes (0998 et 0999) are reserved to prevent conflicts when creating a new user code.Reserved Codes000000From 9998 to 9999From 99998 to 99999From 999898 to 999999From 314157 to 314159All user codes  +1All user codes  +2All user codes  -1All user codes  -2Reserved CodesUp to 49 codes (or badges) can be registered into the panel with the engineer code. A code has 4 to 6 digits (0 to 9).The table presents the reserved code possibilities that cannot be used.Those codes are used for maintenance or as panic/duress codes.A total of 186 codes are forbidden.Enter a new end user Badge/Code Delete an end user Badge/CodeENTER A BADGE/CODEPress twice on the right arrowDELETING BADGES/CODESBadges/codes listSelect badge/code thenOK or YESDELETING CODEACCESS 5CODEDELETEDBADGE OR CODECODE NAME :CONFIRM THE  CODEACCESS 2  ENTRY COMPLETEBADGESACCESS CODESENTER A BADGE/CODEEnter a 4-6 digit user code andOK or YESor present a badge in front of the reader until you hear the registration beep.OK or YESOK or YESOK or YESOK or YES OK or YESOK or YESINSTALLATION MANUAL
19W and WIP Panel www.videofied.com3. W panel features guide3.5 Delete the keypad or any other deviceYou can now remove the batteries from the deviceACCESS LEVEL4CONFIGURATIONGENERALPARAMETERSOK or YESto select the device and pressOK or YES< = = = = XX = = = = >DELETEAREAS ANDDEVICESDEVICESADD A NEWDEVICEDEVICECONFIGURATIONA1 : KEYPADKEYPAD 1OK or YESOK or YESOK or YESDevices listOK or YESOK or YESINSTALLATION MANUAL
20W and WIP Panel www.videofied.com3. W panel features guideWhen user disarms the system, the keypad indicates the last event. In case of the user needs to read the full log file, use the keypad to go in EVENT LOG, press OK or YES on SELECT LAST EVENTS and use arrow to list the events.3.6 Read the event logPress OK or YES for more information about an eventEVENTLOGSELECT LAST EVENTSOK or YES 15/10/13  11:29MODIFIED PARAMETOK or YES 15/10/13  11:10SYSTEM DISARMED3.7 Golden rulesArea 1 device are delayed  by default (Area mode parameter set as Auto).  When you register a keypad or a badge reader into an area set as Auto, that area will automatically be delayed.Never position a panel next to a high voltage electrical cabinet. The interference will affect radio and 2G3G performance.Press CLR to erase a typing mistake.Never register the same device twice (delete from the system first).The panel can register of  up to 25 devices of all types, including the keypad and the keyfobs.Follow the Motionviewer installation instructions. Consider the infrared field of detection when installing the Montionviewer cameras, in order to protect goods or an entry point instead of a zone.1.2.3.4.5.6.Do not fix the keypad at the beginning of the installation as it will need to be portable during programming.Always clean the lens of the cameras after the installation. Use a clean, dry cloth, taking care not to exert pressure on  the lens.Internal components are fragile, be careful opening or closing the panel.LCD screen goes dark after 30 seconds of inactivity, press an arrow or numeric key to light it up.Infrared detectors should never be installed in stairs or close  to stairs (false alarm risks).A colon display [:] means that the parameter can be changed. Press OK / YES to display the colon7.8.9.10.11.12.INSTALLATION MANUAL
21W and WIP Panel www.videofied.com4. Ethernet parametersTo configure or modify Ethernet Parameters, go to: •  IP Parameters: If you wish to use the Ethernet transmission mode, two options are available:1.  DHCP Enable: IP address is assigned by the DHCP service on the network. (Dynamic IP address). This is the default option. 2.  DHCP Disable: IP address must be defined in Ethernet parameters.  IP address will NOT be automatically obtained from DHCP service on the network. Each connection from the panel to the network (alarms transmission), the XT-iP will have the same connection parameters. You must first connect to the router in order to get the network parameters and all available IP addresses. The following parameters must be filled in the IP PARAMETERS sub-menu: PANEL IP, IP MASK, GATEWAY, PRIMARY DNS, SECONDARY DNS. •  Constant Ethernet:Three options are available: 1.  “Auto” Mode - We recommend this mode. If main powered, the panel will be connected constantly to the local Network. In case of an alarm, the alarm will be sent in few seconds to the monitoring station. When the main power is cut, the Ethernet module will switch off aer a delay (DELAY BEFORE OFF – 30 by default) in order to save battery life. In case of an alarm, the panel will at first connect to the local Network. It adds few seconds to the total process of sending an alarm.    You can set the delay in this menu :  CONFIGURATION (LVL 4) > GENERAL PARAMETERS  > ETHERNET > CONSTANT ETH.  > DELAY BEFORE OFF. 2.  “ON” Mode - The panel will be connected constantly to the local Network. This option will impact back-up battery life. 3.  “OFF” Mode - For each transmission of alarm and video, the panel will connect to the local Network.•  PING reply, Time Out Server, Max Seg. Size: •  PING REPLY: Enables ping response.•  Time Out Server: In case of disconnection to the local Network, the panel will try aer that time to re-connect.•  Max Seg. Size: Maximum size of packet sent.ETHERNETGENERAL PARAMETERSLvl. 4CONFIGURATIONTo configure Ethernet parameters, using the direction arrows, go to the menu : OK or YES OK or YESINSTALLATION MANUAL
22W and WIP Panel www.videofied.comThe  W panel can be configured to enable or disable the transmission of specific events like alarms or malfunctions.The installer can modify the default sending settings for those events, although it will end the EN50131 standard compliance. 5. Transmitted events listHow to modify the transmission state • At initial programming,  right aer the PERIODIC TEST CALL step: • Aer initial programming, using a remote keypad  : Example : If the monitoring station system is set to receive arms and disarms, the ARM / DISARM parameter must be changed from NOT TRANSMITTED to ALARM / END.Press OK or YES to access EVENT TRANS. MODIFICATION menu.CODE/STATE MODIFICATIONUse the arrows                     to access :CONFIGURATION  (level 4) > CONFIGURATION MONITOR. STATION > MONITORING PARAMETERS > EVENT TRANS. MODIFICATIONThen use the arrows        to determine the event to modify. Press OK or YES  to edit.These are the default transmitted events  :DEVICE (intrusions)  ALERT (Panic Buttons)PANEL LOW BATT.TAMPERDEVICE LOW BATT.PERIODIC TESTDURESS CODEFIREMEDICAL ASSIST.ETHERNET CABLE AC POWER LOSS (AC Power supply) The following events are not sent by default :PANEL RESETPHONELINE FAULT RADIO JAMMINGSUPERVISION5 WRONG CODESALARM CANCELARM/DISARM  (On/Off)ZONE BYPASS (bypass function enabling/dsiabling)SWINGER SHUTDOWNThere is 3 different transmission states :ALARM : event transmitted upon occurrenceALARM/END :  event is transmitted on occurrence and on event restoralNOT TRANSMITTED : event is not transmitted, however it will appear on the keypad. INSTALLATION MANUAL
23W and WIP Panel www.videofied.com2G3G LEVEL :ERROR XXXIn case of  2G3G errors during initial programming, we strongly suggest to continue with the installation and perform the 2G3G level test again once achieved. The following is a list of error codes that can appear aer the 2G3G test.Security limitations on the SIM card must be disabled.The PIN of the SIM card has to be disabled or 0000.6. 2G3G error codesCodes Errors     03 ou 04LP No network coverage or no SIM card inserted003 SIM card not detected/not inserted010 SIM not inserted011 PIN code necessary                                                                                                                                                                   -> PIN code must be deactivated012 PUK code necessary, SIM card blocked013 Default SIM card014 SIM card busy015 Error on SIM030, 043, 057, 102 , 132, ...•  No network coverage •  Typographical error in the APN Code, username, password •  SIM card not activatedThis error checklist is provided for information purposes only. This is not a comprehensive list, but it is representative of most cases. Some events or codes are subject to change by SIM card operators. However, the 2G3G level test errors  results in the majority of cases  have the following causes :•  SIM Card activation Delay:    Some operators require an additional delay up to 48 hours to  activate automatic data transmission. Please check with your operator prior to installation.•  APN CODE, USERNAME and PASSWORD : The 2G3G settings are supplied by the operator. Please make sure you have entered the code exactly as indicated by your local SIM card operator.Note: When entering your SIM card settings, both APN codes, username and password fields are case sensitive! (It makes a difference between UPPER and lower case letters).To switch between UPPER and lower case, use the M/m key from CMA keypad or hold a digit key (0-9) for XMA/XMB.Insufficient GPRS Network: When the panel is unable to find any signal, proceed to GPRS level test in another location on site. You can also find the network state or condition of use by directly contacting your local operator.INSTALLATION MANUAL
24W and WIP Panel www.videofied.com7. Security and certification notes INSTALLATION MANUALMatériels de sécurité électroniques, détection d’intrusionCENTRALE D’ALARME + TRANSMETTEUR  Marque commerciale : Référence Produits : N° de Certification :Videofied Centrale WIP210Videofied Centrale WIP220Videofied Centrale WIP230Videofied Centrale W210Normes :NF EN50131-1: 2007 - Grade 2 – Classe IINF EN50131-3:2009 - Grade 2    &  RTC 50131-3:2009NF EN50131-5-3:2005 - Grade 2NF EN50131-6:2008 Grade 2 –Type B    &  RTC 50131-6:2008NF C 48-212:2004NF EN50130-4:1995; A1:1998; A2:2003 NF EN50130-5: 1998 Classe IIOrganisme certificateur :CNPP Cert. Route de La Chapelle Réanville CS22265F—27950 SAINT MARCELTel : +33(0)2.32.53.63.63Fax: +33(0)2.32.53.64.46Sites Internet : http://www.cnpp.comEmail : certification@cnpp.comOrganisme certificateur :AFNOR Certification11, rue François de Pressensé93571 Saint Denis La Plaine CedexTel : +33(0)1.41.62.80.00Fax: +33(0)1.49.17.90.00Sites Internet : http://www.afnor.org et http://www.marque-nf.comEmail : certification@afnor.org Certifications868MHz (WIP 210/220/230 and W 210)Compliant with the annex IV from the R&TTE 1999/5/CE DirectiveNF&A2P - 2 boucliers – suivant le référentiel NF324-H58915MHz (WIP 620 /630) UL 1610USA FCC (Part 15C, 22H, 24E and 27)  Canada IC (RSS-210 Issue 8, RSS-132, RSS-133 and RSS-139) 920MHz (WIP 720/730)Australia A-Tick(AS/NZS4268, AS/CHS42 and AS/NZS 60950)Ce symbole, apposé sur le produit ou sur son emballage, indique que ce produit ne doit pas être traité avec les déchets ménagers. Il doit être remis à un point de collecte approprié pour le recyclage des équipementsélectriques et électroniques. En s’assurant que ce produit est bien mis au rebut de manière appropriée, vousaiderez à prévenir les conséquences négatives potentielles pour l’environnement et la santé humaine. Le recyclage des matériaux aidera à préserver les ressources naturelles. Pour toute information supplémentaire au sujet du recyclage de ce produit, vous pouvez contacter votre municipalité, votre déchetterie ou la société qui a installé le produit.
25W and WIP Panel www.videofied.com7. Security and certification notes INSTALLATION MANUALNotes de sécurité / (EN) Security notes / (DE) Hinweise zur SicherheitFrançais•  Retirez la batterie avant toute opération de maintenance !•  Attention ! Il y a un risque d'explosion si la batterie utilisée est remplacée par un mauvais modèle !•  Respectez la polarité lors de la mise en place de la batterie !•  Ne jetez pas la batterie usagée ! Ramenez-la à votre installateur ou à un point de collecte spécialisé.English•  Remove the battery before any  maintenance !•  WARNING, there is a risk of explosion if a battery is replaced by an improper model !•  Observe polarity when setting up the battery!•  Do not throw the battery when it is used! Dispose of it properly according to Lithium Metal requirementsDeutsch•  Batterien vor jeglichen Wartungsarbeiten entfernen!•  Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Models ersetzt wird!•  Achten Sie beim Einsetzen der Batterie auf die Polung! •  Entsorgen Sie Batterie nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterie zu den öffentlichen Sammelstellen.FCC Regulatory Information for USA and CANADAFCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment.FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:>  Reorient or relocate the receiving antenna.>  Increase the separation between the equipment and receiver.>  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.>  Consult the dealer or an experienced radio/TV technician for help.Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subject to the following two conditions:1  This device may not cause harmful interference, and 2  This device must accept any interference received, including interference that may cause undesired operation.Cet appareil est conforme à la Partie 15 des règlementations de la FCC et avec la norme RSS-210 de l’Industrie Canadienne.Son fonctionnement est soumis aux deux conditions suivantes :1  Cet appareil ne doit pas causer d’interférences nuisibles et 2  Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable.
 26North American Headquarters1375 Willow Lake Blvd, Suite 103Vadnais Heights, MN 55110USAE-Mail : usasales@rsivideotech.comEMEA SALES23, avenue du Général Leclerc92340 BOURG-LA-REINEFRANCEE-Mail : emeasales@rsivideotech.comW and WIP Panel www.videofied.com8. Technical specifications INSTALLATION MANUALElectrical dataPower SupplyW210 / WIP 210 / WIP 220 / WIP 230 5VDC/1A Mini-USB connector AC/DC adapter (110/230VAC/50-60 Hz) available (WPS100)WIP 620 / WIP 630 / WIP 720 / WIP730 12VDC/1A - Wire connection  Backup battery Battery technology   Rechargeable 3.7V Lithium-ion batteryBattery voltage (Fully charged)  4.1 VLow battery level  3.95 VGuaranteed autonomy when the low battery level is reached    3 days with 6 alarmsAverage current consumption in standby mode  600 µAMax consumption  1 ARF S2View® technologyRadio type  Bidirectionnal RFOperating frequency   868MHz - WIP210/220/230 - W210 (Europe, South Africa, Asia)  915MHz - FHSS - WIP620/630 (USA, Canada, South America)  920MHz - FHSS - WIP720/730 (Australia, South America)Transmission security   AES encryption algorithmRadio jam detection  YesSupervision YesAntenna   IntegratedTamper DetectionTamper  Wall and cover tamper detectionTransmissionCommunicatorCommunicator type  2G & LAN Ethernet (WIP210)  2G (W210)  LAN Ethernet (WIP220 / WIP620 / WIP720)  3G & LAN Ethernet (WIP230 / WIP630 / WIP730)Security protocol  FrontelIP Stack  TCP/IPVideo transmission  By Frontel protocol to   central monitoring station or App servers2G3G Antenna  IntegratedOptional modules Wi-Fi  WWB100 (WLAN 802.11 b/g/n)Wired Input/Outputs  WIO100 (out of NF&A2P compliance)Wired Siren  WIS100Video Video format  WMV or MPEGImages  per second   5Image size  320x240 or 640x480 pixelsVideo length  4 to 12 secondsMiscellaneousProgramming  Keypad or USBMax number of devices  24Max number of codes/badges  50Arming modes  4Areas 4Event log   4,000 events stored on  flash memoryBoxPhysical and Environmental DataOperating temperature  -10°/+55°CMaximum relative humidity  75%, non-condensingMaterial ABS—ULV0International Protection Marking  IP31 / IK06DimensionsPanel  143 mm x 200 mm x 44mm (LxWxD)Installation/MountingControl Panel/Base   Two screws secures control panel cover to base; Three screws    secure control panel base to the wall