RF Controls RFC-6100XR RF ID Interrogator User Manual User Guide

RF Controls, LLC RF ID Interrogator User Guide

User Manual

SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 1    User Guide  SASL™ (Signal Acquisition & Source Location unit)      RF Controls Intelligent Tracking and Control System (ITCS™)     ITCS-A-21X Family SASL Antenna Models  ITCS-A-210 ITCS-A-212  Configured with an RFC-6100XR RFID Reader  Revision History Change Date Description  1.00-  FAE 2013 1st Draft from A-20X Family 1.10-  Andrew Crook Add New Reader Figures and Update Company info 1.20-  Andrew Crook Change Model Number and revise body 1.30-  April 2014  Edit for UL/FCC 1.40-  May 2014  Ionizing Distance 23cm     © 2014 RF Controls, LLC. All rights reserved.  No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from RF Controls. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 2 Introduction   This SASL™ User Guide provides the basic information needed to install an individual SASL antenna unit containing an RFC-6100XR RFID Reader.  This guide is not intended to provide instructions for installing, configuring and calibrating the RF Controls Intelligent Tracking and Control System (ITCS™).  Detailed instructions are provided in the Technical Manual (ITCS-A-100-002) and Programmer’s Reference Guide (ITCS-A-100-003).    INTENDED AUDIENCE  This guide is intended for those who will install and set up the RF Controls SASL (Signal Acquisition and Source Location) unit. Before attempting to install, configure and operate this product, you should be familiar with the following:    Windows based software installation and operation   Device communication parameters including Ethernet and serial communications   RFID reader configuration including antenna placement and RF Parameters   Electrical and RF safety procedures.   CONTENTS   1.  SASL overview 2.  Installation 3.  Software  4.  Specifications 5.  Safety instructions   FCC NOTICE  This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   CONTACT INFORMATION  RF Controls, LLC 1400 South 3rd Street, Suite 220 Saint Louis, Missouri         63104 USA  Phone:   +1 314 584-1500                 +1 314 571-6200 Fax:       +1 314 584-1549 Web site:  http://www.rfctrls.com   e-mail:   inquires@rf-controls.com e-mail:   techsupport@rf-controls.com
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 3 SASL OVERVIEW   SASL is a multi-protocol, multi-regional Radio Frequency Signal Acquisition & Source Location unit, which is used to Identify and locate RFID tags operating in the UHF 860 – 960 MHz frequency band.  A number of SASL units may be used together with an ITCS Location Processor to form an Intelligent Tracking and Control System (ITCS). SASL comprises an embedded multi-protocol, multi-regional RFID reader/writer transceiver connected to the patented steerable phased array antenna system.  SASL is designed to be powered from AC mains or Power-Over-Ethernet and communicates with a host computer using standard Ethernet TCP/IP and UDP protocol.  Figure 1 illustrates the Four versions of SASL currently available.  All models are equipped with identical Array Controllers.  The ITCS-A-210 and ITCS-A-212 contain the RF Controls RFC-6100XR RFID reader.       ITCS-A-210 are constructed using eight Bi-directional Electronically Steerable Phased Arrays (BESPA™) arranged to provide a single array with a circularly polarized gain of more than 10dBi.    ITCS-A-212 are constructed using four BESPAs arranged to provide a single array with a circularly polarized gain of more than 7 dBi.    The particular units used in an installation will depend on the system design and determined by a qualified applications engineer. The two models may be intermixed as required in a single ITCS system.       ITCS-A-210  ITCS-A-212  Figure 1  SASL (Signal Acquisition and Source Location) Units
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 4 INDICATOR LIGHTS   ITCS-A-21X Reader Indicator Lights  The RF Controls RFC-6100XR RFID reader is equipped with four status indicators located on the top of the enclosure.  From top to bottom, these LEDs provide indication according to the following table:  Indication Color/State Indication Tag Sense Off No Tags Detected Blue Tags Detected Transmit Off RF Off Yellow Transmit Active Fault Off OK Red-Flashing Error/Fault Blink Code Power Off Power Off Green Power On   Note that when the RFC-6100XR reader is performing power on auto-test, the indicator lights will flash momentarily.    Figure 2  RF Controls RFID Reader Indicator Lights.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 5  Installation    MECHANICAL INSTALLATION  Each model of the ITCS-A-21X family of SASL units is mounted slightly differently.  SASL units weigh up to 100 lbs (46.3 kg), so it is important to ensure that the structure, to which the SASL is to be attached, is of sufficient strength.  The SASL may be ceiling mounted, wall mounted or attached to a suitable stand.  A safety cable rated at three (3) times the hanging weight of the SASL and associated hardware must be secured to a separate fixture and attached to the SASL mounting bracket.  When mounting the SASL as a stand-alone unit, make sure that it is mounted the correct way up as indicated by information in the Technical Manual, for the specific SASL.  If the SASL is one of several and is part of an ITCS network, then orient each SASL according to the ITCS system installation drawings.  If in doubt contact a member of our technical support team.  ITCS-A-210 The ITCS-A-210 SASL is provided in its standard configuration with a mounting bracket for installation in a landscape orientation.  When mounting the SASL refer to Figure 4.  Consult the Technical Manual, for further information.  Contact a member of our technical support team for more information.    ITCS-A-212 The ITCS-A-212 SASL is only mounted in a landscape orientation because the array is symmetrical, there is no benefit to mounting the array in a portrait fashion.  When mounting the SASL refer to Figure 4.  Consult the Technical Manual, for further information.  Contact a member of our technical support team for more information.    When mounting the SASL as a stand-alone unit, make sure that it is mounted the correct way up as indicated by information in the Technical Manual, for the specific SASL.  If the SASL is one of several and is part of an ITCS network, then orientate each SASL according to the ITCS system installation drawings.  If in doubt contact a member of our technical support team.     SAFETY WARNING The ITCS-A-200 SASL weighs approximately 100 lbs. (49 kg), and ITCS-A-202 weighs approximately 50 lbs (23kg).  These units should only be installed using suitable safety and lifting equipment. Ensure that the wall fixings or mounting hardware is suitably rated.   AVERTISSEMENT DE SÉCURITÉ ITCS-A-200 SASL pèse environ 49 kg, et des ITCS-A-202 pèse environ 23 kg.  Ces unités ne doivent être installés à l'aide des équipements de sécurité et de levage approprié.  Veiller à ce que les fixations murales ou le matériel de montage est convenablement évalués.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 6 ELECTRICAL INSTALLATION   POE Power Input POE power input is available only for the ITCS-A-210 and ITCS-A-212 using the RJ-45 connector as shown in Figure 4.  Connect POE power supply and plug it in to a suitable mains outlet and the POE Bias T.  POE power, DC Input equivalent to IEEE 802.3at.  Note that the power for the POE bias T should be located in close proximity to the SASL and should be accessible to enable easy disconnection of the power to the SASL in case of emergency or when servicing.   AC Mains Input AC mains input is an IEC connector as shown in Figure 4.  Connect the provided IEC mains cord to the power supply and plug it in to a suitable mains outlet.  Note that the mains outlet must be located in close proximity to the SASL and must be accessible to enable easy disconnection of the mains supply to the SASL in case of emergency or when servicing.  The form and location of the AC mains input is the same on the ITCS-A-210 and ITCS-A-212.   Ethernet The Ethernet LAN connection uses the industry standard RJ-45 connector.  A suitable Ethernet cable fitted with an RJ-45 plug is connected to the SASL Array Controller box as shown in Figure 4.  The SASL is factory programmed with a fixed IP address which is shown on the label adjacent to the Ethernet connector.  The form and location of the Ethernet connection Input is the same on the ITCS-A-210 and ITCS-A-212.     Figure 4    ITCS-A-210 and ITCS-A-212 Power and Ethernet Connections are similar in form and location.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 7  WARNING The SASL is not user serviceable.  Disassembly or opening the SASL will cause damage to its operation, will void any warranty and may invalidate the FCC type approval  Non Ionizing Radiation This unit incorporates a Radio Frequency Transmitter and should therefore be installed and operated so as to avoid exposure of any persons to unsafe emissions. A minimum separation distance of 23cm must be maintained at all times between antenna and all persons. See FCC Radiation Exposure Statement in the Safety Instructions section of this guide.   Notice for European Installers The Installer shall ensure that he is familiar with any restrictions of the local EU Member State on the use of this device and ensure compliance!  Examples may include: restrictions on geographic location or only for indoor use etc.  Due to differences between ETSI and FCC frequency bands, “Phase Ranging” Techniques are not available with the ETSI version of the SASL.  Usable Frequency Range in US and Canada In USA and Canada this device is factory programmed to operate in ISM 902MHz – 928MHz band.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 8 MULTIPLE SASL UNITS CONFIGURED AS AN ITCS   Figure 5 shows how two or more ITCS-A-21X SASL units may be connected via an Ethernet network to an ITCS Location Processor.  One Location Processor and multiple distributed SASLs operate collaboratively to form RF Controls’ Intelligent Tracking and Control System (ITCS™).  In this example two SASL units have been attached to the network. Combinations of the various model SASL units may be mixed and matched as required to suit a particular installation.  The RF Controls Technical Manual provides details on how to install, configure and calibrate an ITCS.  The Programmers Reference Guide provides details of the Application Program Interface (API) used by the ITCS.        Figure 5 Intelligent Tracking and Control System comprising a number of SASL units connected via an Ethernet Network to an ITCS Location Processor
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 9 Software    The SASL is provided with a basic test program on a CD, to run on a Microsoft™ Windows® equipped Personal Computer.  The program enables you to carry out a number of basic tests.  See the Technical Manual for further instruction on Software usage.   APPLICATION INTERFACE  The SASL uses an International Standard, Application Program Interface (API) as defined in ISO/IEC 24730-1. Further details of the API and commands are contained in the Programmer’s Reference Guide.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 10 Specifications  General ITCS-A-210 ITCS-A-212      Frequency    UHF band: 860 – 960 MHz1  RF Radiated Output Power Adjustable from 0.2 to 4 Watts EiRP Regulatory Compliance FCC, CFR47 Part 15.247 EN 302 208, EN 301 489-3, EN 301 489-1, EN55022, EN55024, EN 60950-1:2005  Reading/writing Protocols ISO18000-6C / EPC UHF Gen 2 EM 4122 (TTO) FCC ID  IC ID WFQRFC-6100XR    10717A-RFC6100XR  Application Interface ISO/IEC 24730-1   Environmental    Operating Temperature +14 to +130 °F (-10 to +55°C) Storage Temperature -40 to +85ºC Relative Humidity 5 to 95% non-condensing Dimensions 68in x 36in x 5in  (170 x 90 x 13 cm)) 36in x 36in x 5in (90 x 90 x 13 cm) Weight 100 lbs (46 kg) 54 lbs (25 kg)   Ethernet LAN  Connector RJ-45 Ethernet   10/100 BaseT Indicators Yellow – link operational Green – network traffic detected Signals Pin 1 TXD + Pin 5 NC  Pin 2 TXD  - Pin 6 RXD -  Pin 3 RXD + Pin 7 NC  Pin 4 NC Pin 8 NC   Power Supply  AC Mains Input POE DC Input  IEEE 802.3at Input Connector IEC/EN 60320 C14 RJ-45 Voltage 90 – 265 Volts AC +48V Frequency 47 – 63 Hz DC Current 3A 0.7A Antenna    Gain2 (circularly polarized) TBD dBi2 TBD dBi2                                                 1 The SASL uses the RFC RFC-6100XR RFID reader which will be factory set at time of shipping, to suit the country of installation and use.  2 To Be Determined at test.  Nominal maximum value.  Precise gain depends on transmit frequency
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 11 Safety Instructions      Consignes de Sécurité   This unit emits Radio Frequency non-ionizing radiation.  The installer must ensure that the antenna is located or pointed such that it does not create an RF field in excess of that permitted by the Health and Safety Regulations applicable to the country of installation.  Cet appareil émet Radio Fréquence rayonnements non ionisants.  L'installateur doit s'assurer que l'antenne est située ou orientée de façon à ne pas créer un champ RF supérieure à celle permise par le Règlement sur la santé et applicable dans le pays d' installation.   Setting RF Output Power Enter the desired RF output power as a percentage of the maximum power into the Set Power box.  Click the set Power button.  Note: the actual maximum Radiated RF Power is factory set to comply with the radio regulations in the country of use.  In the USA and Canada this is 4 Watts EiRP and under EN 302 208 this is 2 Watts ERP (3.2 W EiRP).  Entrer la puissance de sortie RF souhaité sous forme d' un pourcentage de la puissance maximale dans la zone d'alimentation Set.  Cliquez sur le bouton ensemble d'alimentation . Remarque: le maximum réel rayonnée de puissance RF est réglé en usine pour se conformer à la réglementation de radio dans le pays d'utilisation.  Aux Etats-Unis et au Canada c'est 4 Watts EiRP et selon la norme EN 302 208 c'est 2 watts ( 3,2 W PIRE).   FCC Radiation Exposure Statement The antenna used on this equipment must be installed to provide a separation distance of at least 23cm from all persons and must not be co-located or operated in conjunction with another antenna or transmitter.   L'antenne utilisée sur cet équipement doit être installé pour fournir une distance de séparation d'au moins 23cm de toutes les personnes et ne doit pas être co- implantés ou exploités conjointement avec une autre antenne ou émetteur .   FCC Part 15 Notice This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   FCC and Industry Canada Modification Warning Statement Modification of this device is strictly prohibited.  Any modifications to the factory hardware or software settings of this device will void all warranties and be deemed non-compliant with FCC and Industry Canada Regulations.  La modification de ce dispositif est strictement interdite.  Toutes les modifications apportées au matériel d'usine ou les paramètres du logiciel de cet appareil annulera toutes les garanties et sera considérée comme non conforme aux normes FCC et d'Industry Canada.
SASL User Guide v1.40 - Part # ITCS-A-100-001 v1.40 May 2014 12  Industry Canada Statement This device complies with Industry Canada licence-exempt RSS standard(s).  Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  Cet appareil est conforme aux normes d'Industrie Canada exempts de licence(s) RSS.  Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent provoquer un fonctionnement non désiré de l'appareil.   Power Disconnect Device The plug on the power supply cord is intended to be the power disconnect device.  The power source (socket or outlet) shall be located near the equipment and shall be easily accessible.   La fiche du cordon d'alimentation est destiné à être le dispositif de coupure de courant.  La source d'alimentation (prise ou sortie ) doit être située près de l'équipement et doit être facilement accessible .   Statement of Compliance with R&TTE Directive RF Controls, LLC hereby declares that it’s ITCS-A-200, and ITCS-A-202 products are in compliance with the essential requirements and other relevant provisions of European Directive 1999/5/EC.  The original Certificate of Conformity is available at www.rf-controls.com        The SASL products and individual BESPA components are protected by one or more US and International Patents pending.   The “RF Controls” logo, and the words “RF Controls, Identify, Locate, Track”, “ITCS”, “SASL” and “BESPA” are registered Trademarks of RF Controls, LLC.   RF Controls, LLC 1400 South 3rd Street, Suite 220 Saint Louis, MO   63104-4430 USA  Phone:   +1 314 584-1500         +1 314 571-6200 Fax:        +1 314 584-1549 e-mail:   techsupport@rf-controls.com Web site:  http://www.rfctrls.com     e-mail: inquires@rf-controls.com

Navigation menu