R tron SNIDEN25 iDen Mini Wireless Repeater User Manual

R-tron Inc. iDen Mini Wireless Repeater

Contents

Part 2

   iDEN MINI User’s Manual     -17- 2.2.6. HPA (High Power Amplifier) The High Power Amplifiers (HPAs) amplifies the transmitted signal from a base station at the final stage of the repeater and vice versa.  Figure 10.  HPA(High Power Amplifier)
   iDEN MINI User’s Manual     -18- 3. Hardware Installation The installation procedure is as follows:  Check List of Items  Mounting  Grounding  RF Connection  Power up 3.1  Check List of Items   Index  Items  Q’ty 1 iDEN MINI  1 2 Power Cord  1 3  Screws for Mounting  4  Items                                                     Figure 11.  Items 1 2 3
   iDEN MINI User’s Manual     -19- 3.2 Mounting iDEN MINI is easy to mount using the assembled mounting bracket, which has Ø9 holes for the provided 5/16" fixing screws.   Figure 12.  Mounting   CAUTION Firmly affix the equipment on the wall of a building and Check necessary.
   iDEN MINI User’s Manual     -20- 3.3 Grounding     A rod on the left side is intended for a building ground. Connect the ground cable to the rod.  Figure 13.  Grounding 3.4  RF Cable Connection a.  Connect a cable from a donor antenna to the DONOR ANTENNA Port. b.  Connect a cable from the SERVICE ANTENNA Port to a repeater’s service antenna.  WARNING Dangerously high voltages may occur and damage the equipment if the equipment is not groundedproperly.
   iDEN MINI User’s Manual     -21-  Figure 14.  Configuration: RF Cable Connection 3.5 Power Up a.  Connect the power cord. b.  Plug the power cord into a wall outlet. c.  Switch on. d.  Check if the green LED at the bottom turns on.   Figure 15.  Power Cord Connection
   iDEN MINI User’s Manual     -22- 4.  Command and Control through the Hyper Terminal   4.1 Setting for Command and Control through the Hyper Terminal    Figure 16.  Local connection to the iDEN MINI Step 1 Open My Network Places.   Step 2 Push the right button of mouse and select the properties.
   iDEN MINI User’s Manual     -23- Step 3 Click the properties of TCP/IP.   Step 4 Set the values and OK as the following. Close all windows.