1     CDMA MINI (RSN-CDMA-23) User’s Manual
2  Notice  Trademark R-tron is a registered trademark of R-tron Inc. Other products and company names mentioned here in this manual might be trademarks or trade names of their respective owners.  Copyright  Copyright  R-tron Inc. 2000-2009 All Rights Reserved   Any  reproduction,  distribution,  or  revisions  of  any  or  all  portions  of  this  manual  is  prohibited without written permission from R-tron Inc.  Notice This document describes the specifications, installation, and operation of the CDMA repeater. Hardware and software mentioned in this document are subject to continuous development and improvement.  Consequently,  there  may  be  minor  discrepancies  between the information in the document, performance, and design of the product. Specifications,  dimensions,  and  other  statements  mentioned  in  this document are subject to change without notice.  Questions or Comments Address: R-tron Inc. 6402 College Boulevard, Overland Park, KS 66211 Phone: +1-913-344-9977, 1-888-31R-TRON Fax: +1-913-344-9988 e-mail: info@r-tron.com Website: www.r-tron.com
3  Safety Precautions    Opening the CDMA equipment could result in electric shock and may cause severe injury.    Connect the equipment frame ground to building ground.    Operating the CDMA with antennas in very close proximity facing each other could lead to severe damage to the repeater.    RF EXPOSURE INFORMATION A minimum separation distance of 7.9 inches (20cm) must be maintained between the user and the external antenna of repeater to satisfy FCC RF exposure requirements. For more information about RF exposure, please visit the FCC website at www.fcc.gov    This equipment is for indoor use only and enables the communication  wiring  to  communicate only inside the building.
5  Glossary  The following is a list of abbreviations and terms used in this manual.  Abbreviation Definition AC Alternating Current ANT Antenna ATT  Attenuator / Attenuation CDMA  Code Division Multiple Access DC Direct Current DL Downlink GND Grounding GUI Graphic User Interface LED  Light Emitting Diode PLL Phase-locked loop PSU  Power Supply Unit RF Radio Frequency RSSI  Received Signal Strength Indication TEMP Temperature UL Uplink VSWR  Voltage Standing Wave Ratio   ALC (Automatic Level Control) ALC feature prevents the repeater from exceeding its maximum output power by reducing the gain automatically. ALC is used to adjust the gain to an appropriate level for a range of input signal levels.  ASD (Automatic Shutdown) Automatic shut down protects the repeater from the oscillation or excessive input signal and eliminates any degradation to the network.  There are three parameters: ASD Level, ASD Time, and ASD Iteration.  If the output power gets higher than “ASD LEVEL”, the repeater will shut down for “ASD TIME” seconds and then it will turn the amp back on to measure the output power again. If this repeats at “Iteration” times, the repeater will shut down completely.
6  1. Introduction CDMA MINI is used to fill out areas in CDMA mobile systems, such as base station fringe areas, business and industrial building, etc. CDMA MINI receives signals from a base station, amplifies and retransmits the signals to mobile stations.  Also  it  receives,  amplifies  and  retransmits  signals  in  the  opposite  direction.  Both directions are served simultaneously with the following features:  Donor antennaServer antennaBaseStation  CDMA’s Key Features  ♦ Programmable Bandwidth and Band » 5, 10, and 15 MHz contiguous and non-contiguous segments » Any Band Combination within 65MHz PCS Band [A,D,B,E,F,C,G] » Two (2) 5MHz segments ♦ Easy and Quick Installation » Web-based GUI » Plug and Play - DHCP Server @ Local Port » Automatic Easy Setup (Recommended) » Isolation Detection ♦ Auto Level Control & Auto Shut Down  - CDMA MINI utilizes the web-based user interface  and web server. There is one physical RJ-45 port: • The Local port provides the on-site access to the repeater. - DHCP server at the Local port enables Plug and Play by automatically assigning the IP address to the user’s computer. • Easy Setup has the following features.   -It will measure the isolation and limit the maximum gain accordingly. This will also enable Auto Level Control as well as Auto Shut Down. These two features are  strongly  recommended  to prevent the uncontrolled power output, which could have an adverse impact on the RF network and  the  repeater.  For  example,  ALC  will  automatically  apply  attenuation  when  the  input  signal strength is increased due to the new base station deployment near the repeater site.
13  3. Hardware Installation The installation procedure is as follows: • Check List of Items • Mounting • Grounding • RF Cable Connection • Power On  3.1 Check List of Items Index  Items  Quantity 1  Repeater  1 2  AC-DC Adaptor  1 3  UTP Cross LAN Cable  1 4  AC Cord  1 5  Anchor Bolts  4 6  CD of the User’s Manual  1 7  Quick Guide  1   Item Figure  AC Cord                Repeater AC-DC Adaptor    UTP Cross LAN CableAnchor Bolts CD of theUser s ManualQuick Guide
14  3.2 Mounting CDMA MINI is easy to mount using the assembled mounting bracket, which has 4 holes for the provided 5/16” fixing screws.  Step 1 : Drill holes directly through the template.   Step 2 : Install the set anchor bolts or the plastic anchor bolts on the holes.    Step 3 : Attach the mounting bracket to the wall using provided bolts or extra screws.
15  Step 4 : Lean the CDMA to hang the topside of the Guide Ring on the mounting bracket,           and push toward the wall to mount.    Step 5 : Fix the CDMA MINI using 8 screws.
16  3.3 Grounding A rod on the left side is intended for a building ground. Connect the ground cable to the rod.
17  3.4   RF Cable Connection Step 1 : Connect a cable from a donor antenna to the Donor Antenna Port.  Step 2 : Connect a cable from a repeater’s service antenna to the Server Antenna Port.    Model  Max Gain  Minimum required isolation (@Max Gain) CDMA MINI  50dB to 80dB  ≥95dB(80dB+15dB)   3.5 Power On  Step 1 : Connect the power cord.  Step 2 : Plug the power cord into a wall outlet.  Step 3 : Check if the green LED at the Top turns on.
18    This repeater follows the below set-up algorithm automatically right after POWER ON    < Auto easy-setup Procedure>   The below algorithm shows how to control Gain, Input / Output Power Level, Service band, ALC Level, ASD Level and path direction by using keypad    display panel.
19  <Key Pad Control>
36  5. Troubleshooting Before contacting your service dealer, please make sure you refer  to  the  following guide.  If the CDMA  MINI  does  not  work  normally  after  completing  the  following  troubleshooting,  please contact your local dealer or service center.  Problem  Cause  Solution No LED on    Check the power cord for secure connection. Cannot communicate with the repeater.   Redo the ‘4.2, Network Setup’ of this manual. If communication still does not work, please contact Technical Support. Web site: www.r-tron.com Toll Free: 888-31R-TRON The mobile phone is not working well.   Check if the power is ON Check if the DL Amplifier and the UL Amplifier of Parameter Status are displayed as ”ON”. 1. Gain, Input/ Output power or DC current are changed randomly under operating of DL ALC, UL ALC, and ASD. 2. Over isolation attenuation range. Oscillation  a. Turn off the repeater b. Measure the isolation and verify if the isolation  between  the  donor  antenna  and the  service  antenna  is  enough  for  the repeater. Refer to the note on page 19 If  the  measured  isolation  value  is  greater than  the  required  isolation  value,  turn Power ON.   The red light turns on.   Check if DL Input Power, DL Output Power, UL Output Power, Temperature, DC Voltage, DC Current is out of range. Especially, if the Input Power or Output Power is out of range, please contact Technical Support. Web site: www.r-tron.com Toll Free: 888-31R-TRON
39  7. Appendix CDMA Band Diagram
40  Warranty LIMITED WARRANTY This product, as supplied and distributed by R-tron, in the original carton, is warranted by R-tron against manufacturing defects in materials and workmanship for a limited warranty period of:  Five (5) Year Parts and Labor  This  limited  warranty  begins  on  the  original  date  of  purchase,  and  is  valid  only  on  products purchased and used in the United States. R-tron will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above. All  replaced  parts  and  products become the property of R-tron and must be returned to R-tron. Replacement parts and products assume the remaining original warranty. This limited warranty covers manufacturing defects in materials and workmanship encountered in normal, and except to the extent  otherwise  expressly provided for in this statement, use of this product, and shall not apply to the following, including, but not limited to: damage which occurs in installation; applications and uses for which this product was not intended; altered product or serial numbers; cosmetic damage or exterior finish; accidents, abuse, neglect, fire, water, lightning or other acts of nature; use of products, equipment, systems, utilities,  services,  parts,  supplies, accessories,  applications,  installations,  repairs,  external  wiring  or  connectors  not  supplied  or authorized by R-tron which damage this product or result in service problems; or incorrect electrical  line  voltage,  fluctuations  and  surges;  customer  adjustments  and  failure  to  follow operating  instruction.  R-tron  does  not  warrant  uninterrupted  or  error-free  operation  of  the product.  THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE LISTED AND DESCRIBED ABOVE, AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY AFTER THE EXPRESS WARRANTY PERIODS STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY GIVEN BY ANY PERSON, FIRM OR CORPORATION WITH RESPECT TO THIS PRODUCT SHALL BE BINDING ON R-tron.
41  Return Material Authorization(RMA) Procedure  The return and exchange of products are not allowed without prior approval from R-tron America, Inc. Please follow the exchange procedure below.  1. Call Tech Support for troubleshooting. 2. If the device has a hardware problem, R-tron will replace it if it is within warranty. A RMA number will be issued for the return. 3. R-tron will ship the replacement and a return label will be provided. 4.  The  customer  must  return  the  product  using  the  original  packaging,  including accessories.

Navigation menu