R tron RSP-DPP-1900 HB1900 User Manual Revision 2

R-tron Inc. HB1900 Users Manual Revision 2

Users Manual Revision 2

R-TRON Proprietary & Confidential                                           Page 1      HB 1900 (Heartbeat 1900) User’s Manual
R-TRON Proprietary & Confidential                                           Page 2   Copyright Copyright of this manual belongs to R-tron America, Inc. Reproduction, distribution or revision of part or all of contents in this manual in any form without written permission of R-tron America, Inc. is not permitted Registered Trademark R-tron      is registered trademarks of R-tron America, Inc Other products and company names mentioned herein this manual might be trade marks   or trade names of their respective owners.   HB 1900                Copyright © 2004 R-TRON, Inc. All Rights Reserved  Copyright © 2005 R-tron America, Inc. All Rights Reserved The results of using information not mentioned in this manual or the risk of misunderstanding this document remain with the user. The information in this manual is subject to change due to function enhancement, change of design, etc. If you want the modified manual or have any question on this manual, please contact us at:  R-tron America, Inc Address : 10977 Granada Lane, Suite #225           Overland Park, KS 66212 Tel :  +1-913-593-5205
R-TRON Proprietary & Confidential                                                 Page 3    Revision History   Version  Date of revision  Reason for revision Revision DescriptionV1.0  Sep.21.2005  The First Edition   V1.1  Oct.05.2005 Second Edition             RF EXPOSURE INFORMATION  The antenna used for this transmitter must not exceed 2.5dBi and must be installed to provide a minimum separation distance of 20cm from all persons.
R-TRON Proprietary & Confidential                                           Page 4    1. Overview HB(Heart Beat)1900 is designed for the purpose of checking the repeater systems which were installed in Sprint network.   Using CDMA 1x modem protocol, heartbeat is happened only when the repeater system operates correctly. It traces the repeater status and give heartbeat signal periodically to WNMC server through SNMP Trap.   <Heartbeat transfer Configurations>  2. HB 1900 Description
R-TRON Proprietary & Confidential                                           Page 5    2.1 HB 1900 Specification 2.1.1 Environmental conditions Item  Standard  Remark Power supply  85V~264V, 50/60Hz typ.   Operating temperature  - 20 ~ +50℃  Storage temperature  - 30 ~ +60℃  Humidity 95 %  Consumption power  15W   Table 1. Environmental Specification of HB 1900  2.1.2 System Specification Item  Specifications  Remark Down Link  1930 ~ 1990MHz   Frequency range  Up Link    1850 ~ 1910 MHz   Heartbeat interval  3~59 min   Interface Connector  RS-232C   VSWR  ≤1.5  Atten Range  1~30dB  1dB Step Atten Control Accuracy  ±1.5dB  Dimension(W*D*H) 170*300*74 Unit : mm Weight 2.4kg   Table 2. features Specification of HB 1900  2.2 HB 1900 Block Diagram
R-TRON Proprietary & Confidential                                           Page 6   3. SUB Unit description & Specification 3.1 Attenuation Module  <Figure 1 Attenuation Module>                    <Figure 2 Block diagram>  Attenuation Module function is sending signal to modem which is properly leveled and it sends Signal to repeater wirelessly, controlling modem output level.  * Specification * Item  Specifications  Remark Down Link  1930~1990 MHz   Up Link  1850~1910 MHz   Frequency range  Ant <-> In/Out Insertion Loss  -15dB ± 1dB Frequency range (1850 MHz ~1990 MHz) @ ATT 0dB Ant Port  -10dBm   Max Input Power  In/Out Port  20dBm(100mW)   ATT Range  30dB / 1dB Step  Active Low VSWR - S11,S22  1 : 1.3 Min   Ant Port  SMA Female Type   RF Connector  In/Out Port  SMA Female Type   Interface Connector  Molex 5264-7p   Operating Temp.  -30℃ ~ +60℃  Operating Voltage  DC 5V ± 0.5V   Dimension(W*D*H)  60*90*30  Unit : mm Table 3. Specification of Atten Module
R-TRON Proprietary & Confidential                                           Page 7    3.2 Wireless Modem (Expedite C201)  <Figure 3 Wireless Modem> Wireless Modem (Expedite C201) is designed for WNMC interconnection function   * Specification * Item  Specifications  Remark Down Link  1930 ~ 1990MHz   Frequency range  Up Link  1850 ~ 1910 MHz   Storage Temperature  -30℃ to + 85℃  Operating Temperature  -20℃ to +60℃  RF Channel Bandwidth  1.25MHz   Frequency Accuracy  ±150Hz  Operating Voltage  3.45V to 4.20V   Maximum Output Power  100mW (20.0dBm)     Dinamic Range  -104dBm ~ -64dBm    3.3 SNMP Board   <Figure 4 SNMP Board>
R-TRON Proprietary & Confidential                                           Page 8   The SNMP Board located in the HB 1900 cabinet which is the essential of the HB 1900.   The SNMP board contains powerful microprocessors.   Operational parameters, such as Heartbeat interval, Modem Attenuation, SNMP version, Site ID, etc. are set using a desktop or notebook and OMT, which communicate, locally via RS-232C cable, with the RRMS. Remote operation is performed via CDMA net  * Connection * Port  Connected to J1 SNMP Board Vcc J4 Debugging port J5  ATTEN Module Vcc & Control D-SUB 9PIN  Local OMT  * LED * LED   TxD  Display communication status between Modem &SNMP Board    RxD  Display communication status between Modem &SNMP Board  OPR  Turn on a light in Heartbeat Range RDY  Turn on a light when modem power is on  3.4 AC/DC Power Supply Unit <Vendor 1>  <Figure 5 AC/DC Power Supply Unit > PSU receives and converts input power (AC 110V) into DC +5V.
R-TRON Proprietary & Confidential                                           Page 9    * Specification * Item  Specifications  Remark Operating Temp  -10 ~60℃℃  Storage Temp  -20 ~70℃℃  Humidity 20%~90%RH   Environmental Cooling method  Natural air   Voltage AC85~264V  Current  3A Max / 5Vdc   Frequency  47~440Hz max(50~60Hz typ)   Leakage Current  0.5mA max.@110V AC    <Vendor2>  * Specification * Item  Specifications  Remark Operating Temp  -10 ~60℃℃  Storage Temp  -20 ~7℃5℃  Humidity 20%~90%RH   Environmental Cooling method  Natural air   Voltage AC85~264V  Current  3A Max / 5Vdc   Frequency 47~440Hz   Leakage Current  0.75mA max. 60Hz
R-TRON Proprietary & Confidential                                           Page 10   3.5 Antenna  <Figure 6 Antenna >  * ELECTRICAL Specification * Item  Specifications  Remark Down Link  1930 ~ 1990MHz   Frequency range  Up Link  1850 ~ 1910 MHz   Max input power  5W   VSWR  Less than 1.5:1   Gain   2.0dBi±0.5     Radiation pattern     Omni-directional   Polarization          VERTICAL   Antenna Type         Sleeve dipole    Impedance           50 Ω   * MECHANICAL SPECIFICATIONS * Item  Specifications  Remark Overall Length of Ant  166.5  ±2.0 mm   Weight    30 g    Temperature -30℃~+70℃  Cover material         Urethane (HI 153-9082)     White COLOR     Connector Type         SMA-Male    4. Installation 4.1 How to install Program File GUI program consists of one exe file. Therefore, you can copy one exe file to your PC and use it.
R-TRON Proprietary & Confidential                                           Page 11    4.2 Connect communication cable   Connect communication cable as followings,            4.3 Power on After connecting the communication cable, you can supply AC power to the HB 1900. As you can see the following picture, when you supply AC power to the HB 1900, the DC 5V LED light up one time. After 3 or 4 seconds later, the modem power(3.3Voltage) LED light up two times.   Then 10 seconds later, the LED light three times. This signals that the heartbeat unit is ready for communication. Finally, you can execute GUI program and get the heartbeat communication started.  4.4 How to start GUI Program    Click HB 1900 v1_2.exe.
R-TRON Proprietary & Confidential                                           Page 12   When you click HB 1900 v1_2.exe, you will see the following pop-up window.                                     4.5 How to use and configure the Graphic User Interface (GUI)   4.5.1 Login / Logout          To proceed using the GUI Program, a user should log-in. There are two kinds of users. One is the‘root’ and the other is the‘operator’. The ‘root’ user, the   can control all GUI buttons but the ‘operator’, can not use debugging pop-up window. Input classified user IDs(‘root’ or ‘operator’) and assess password. After that,all default buttons will be activated.  4.6 How to set up a communication port          After setting up the GUI Login, you should set up the communication port between the system
R-TRON Proprietary & Confidential                                           Page 13   and GUI. The Communication protocol is a RS-232C protocol between the SNMP board and the PC serial port which is set up by the GUI. The Current RCU transmit speed is fixed at 11,5200bps. As you can see in the above picture, you can select the proper COM port and then click the ‘START’ button. Now the RCU communication is started. If there is no problem with the communication, the Rx LED will light up green with the Tx and Rx lighting up green, alternately.    4.7 Check setting figures    As shown in the above picture, you can check the Site ID(Cascade Code) , WNMC Phone Number , WNMC IP Address , SNMP Version and Modem Phone Number. When you change the current GUI settings, you can input the needed numbers in the white boxes and click toggle switch to store the values.  4.7.1    How to set Parameter value 4.7.1.1 Cascade code Input ex) Cascade Code which is given by a wireless operator : test01  Type Cascade code in white activated box.               Click “SiteID Set” button.
R-TRON Proprietary & Confidential                                           Page 14       4.7.1.2 Input WNMC Phone Number Sprint WNMC Phone Number is    #777 and procedures is as followings,  Type “#777” in white activated box              Click “Phone Number Set” button     4.7.1.3 WNMC IP Address입력 Sprint WNMC Server IP Address는  10.22.25.15 and procedures is as followings,  Type “10.22.25.15” in white activated box.           Click “IP Address Set” button.
R-TRON Proprietary & Confidential                                           Page 15    4.7.1.4 Input Modem Phone Number Type modem phone number which you are going to put it into HB 1900. Each modem phone number is different.  For example, when it comes to modem phone      Click “Modem NUM Set” number is 5022759735, type this number in white activated box.                  2.4 How to check Modem   You can set the network connection status in ‘modem mode’ using the modem status pop-up window and entering information in the ‘modem statistics’ pop-up window as followings,
R-TRON Proprietary & Confidential                                           Page 16   ①  When the Modem is properly connected, you will see ‘READY’ im green, like in the above picture[number 1]. ②  Then you can click the NMST button [number 2] and test the AT Command. When  you see the ‘OK’ response, this means that the modem and SNMP board status is Okay.   2.5 Check RSSI Value and Set Attenuation  2.5.1 Set Attenuation After check the RSSI value which is displayed on the GUI, set the RSSI value as -70dBm, using the modem attenuation. For example, when the GUI RSSI value is -67dBm, you can set it as -70dBm, using the modem attenuation 3dB. To set the attenuation, you can input the attenuation value in white box and then click the ‘modem atten’ button which is located on the left side to store it. (Ex-factory setting value of HB 1900 : user attenuation is 12dB , Heartbeat interval is 5 minutes.)  Ex) How to set User Attenuation Antenna input Level Fixed Loss  User Attenuation  Reference RSSI Value -30dBm -15dB  -25 dB  -70dBm -40dBm -15dB  -15 dB  -70dBm -50dBm -15dB  -5 dB  -70dBm
R-TRON Proprietary & Confidential                                           Page 17    2.5.2 Set Heartbeat Interval  Type heartbeat interval in white                 Click “Heartbeat Interval” button. activated box.      (Heartbeat Interval Range : 3 ~59 min)      2.6 How to check PPP connection and heartbeat Set heartbeat interval as 20 minutes and then change network connection status to ‘PPP Mode’.            ConnectedHeartbeat Transmit    Status Check

Navigation menu