Quanta Computer LI172 LTE LGA Module User Manual

Quanta Computer Inc LTE LGA Module

User Manual

     Quanta LI172 Test Operation Guide     Version 0.1 Apr.  23,  2014   Winn
  Page 1Contents  1. Introduction .................................................................................................................................... 3 2. Test Environment ............................................................................................................................ 3 2.1. Uninstallation ......................................................................................................................... 3 2.1.1. Windows 7 (32 bit) ................................................................................................................. 3 2.2. Installation of drivers .............................................................................................................. 5 2.2.1. Windows 7 (32 bit) ................................................................................................................. 5 3. Operation of Connection Manager ................................................................................................. 11 3.1. Windows 7 (32 bit) ................................................................................................................ 11 3.1.1. Basic Configuration ................................................................................................................ 11 3.1.2. Extended Information ............................................................................................................13 3.1.3. LTE Manager ..........................................................................................................................15 3.1.4. Manual PLMN ........................................................................................................................16 3.1.5. Change to Commercial Mode .................................................................................................17 3.1.6. Disable Polling .......................................................................................................................18 3.1.7. PIN Management ...................................................................................................................19 3.1.8. Automatic Connect Mode ......................................................................................................20 3.1.9. Device Location .....................................................................................................................21 3.1.10. Help .......................................................................................................................................22 3.1.11. Reset .....................................................................................................................................23 4. Diagnostic Tool ...............................................................................................................................24 4.1. MsgView ...............................................................................................................................24 4.2. DbgView ................................................................................................................................25 5. Firmware Upgrade .........................................................................................................................26 5.1. Image Burn Tool .....................................................................................................................26 6. OMA-DM .......................................................................................................................................30 6.1. Mandatory Configuration .......................................................................................................30 6.2. How to Enable/Disable APN ...................................................................................................31 6.3. How to Modify OMA-DM Server URL .....................................................................................33 6.4. How to Online Enable/Disable Internet APN ..........................................................................35 6.5. How to Enable/Disable OMA-DM log .....................................................................................36 6.6. How to Use VI editor ..............................................................................................................37
  Page 2Revision History  Version  Release Date  Description 0.1  Apr. 23, 2014  1st Test Operation Guide Release
  Page 31. Introduction This document gives the guidance on how to test Quanta devices. 2. Test Environment Quanta  LI172  device  supports  Windows  XP,  Windows  Vista  (32  bit), and  Windows  7  (32  bit)  operating system. It’s recommended to install Quanta LI172 software in Windows 7 32-bit OS. 2.1. Uninstallation In order to install latest version of software, uninstallation of previous version is required, including drivers, connection manager, and corresponding software tools.  2.1.1. Windows 7 (32 bit) 1. Please click   StartProgramsAltair SemiconductorLTE ALT3100Uninstall   2. Please click “Yes (Y)” button.
  Page 43. Please click “Uninstall” button. 4. Please wait a few seconds to complete uninstallation. 5. Please click “Close” button. 6. Please click “OK” button.  7. Please click   “StartProgramsAltair SemiconductorLTE ALT3100HLVUSBUninstall”.  8. Please click “YES (Y)” button. 9. Please reboot your computer after you have completed the uninstallation.
  Page 52.2. Installation of drivers 2.2.1. Windows 7 (32 bit) 1. Please double clicks on “Altair(Quanta) Tool Package v1.0.0.exe” to start installation. 2. Please click “Next >” button. 3. Please click “Install” button. 4. It will take a few minutes to complete installation. 5. Please click “Next >” button.
  Page 66. Please check “I accept the terms in the license agreement”. 7. Please click “Next >” button. 8. Please select “Full Installation” type. 9. Please click “Next >” button. 10. Please click “Next >” button.
  Page 711. Please click “Install” button. 12. Please click “Next >” button. 13. Please click “Finish” button.
  Page 814. Please click “Next >” button. 15. Please check “I accept the terms in the license agreement”. 16. Please click “Next >” button. 17. Please click “Install” button.
  Page 918. Please click “Continue to install driver anyway (I)”. 19. Please click “Continue to install driver anyway (I)”. 20. Please click “Continue to install driver anyway (I)”. 21. Please click “Continue to install driver anyway (I)”. 22. Please un-check “Launch “Hostless Image Burn””. 23. Please click “Finish” button to complete driver installation. 24. Please click “OK” button. 25. Please click “Finish” button.
  Page 1026. Please plug in Quanta device and please be patient and wait a few minutes to complete driver installation. 27. Please click “Close (C)” button. 28. Please reset Quanta device (take out and plug in the usb cable), it will take about 50 seconds for Quanta embedded system to be ready.
  Page 113. Operation of Connection Manager 3.1. Windows 7 (32 bit) 3.1.1. Basic Configuration 1. In order to get information from our embedded connection manager, it’s mandatory to configure as the following instructions. 2. Please click   StartProgramsAltair SemiconductorLTE ALT3100Connection Manager.  3. Please right click on top of connection manager and select   OptionsDevice LocationTechnician PC.  4. Connection manager will pop out window for you to enter IP and port. 5. Please enter IP address “10.0.0.1”. (see NOTE) 6. Please click “OK” button. NOTE: If you have successfully installed Quanta LI172 device, the embedded module will generate DHCP server and its IP address is “10.0.0.1”. Meanwhile, our Quanta device will get a DHCP address “10.0.0.133” automatically.
  Page 127. Please check if connection manager shows device information correctly and the red Altair logo turns into yellow color.
  Page 133.1.2. Extended Information 1. Please right click on top of connection manager and select   ViewExtended Information. 2. Connection manager will pop out “Extended Information” window.  3. It’s NOT mandatory to set up this “Configuration” tab, connection manager will scan all the supported frequency bands and try to connect to the network.
  Page 144. The “Extended Data” tab shows information of Connection Status, APN, Transmission mode, Bandwidth, DL EARFCN, Band, PLMN and Physical Cell ID and so on. 5. The “At Commands” tab will allow you to send AT Commands sets to configure supported functional parameters or to get supported information you want.
  Page 153.1.3. LTE Manager 1. Please right click on top of connection manager and select   ViewLTE Manager. 2. Connection manager will pop out a “Supervisor Password” window.  3. Please input “123456” and click “OK” button. 4. It will pop out a “LTE Manager” window. 5. LTE Manager shows information about GeneralInfo, LogCreator, Dispatcher, Relay, and GPS Tool.
  Page 163.1.4. Manual PLMN 1. Please right click on top of connection manager and select   Manual PLMN. 2. Connection manager will pop out a “Plmn Search” window.  3. It’s not necessary for you to select PLMN manually if you want to connect to network.
  Page 173.1.5. Change to Commercial Mode 1. Please right click on top of connection manager and select   “Change to Commercial Mode”. 2. Connection manager will pop out a “User Mode Changed” dialog.  3. Please click “YES (Y)” button. 4. Please wait a few seconds for device to be ready.
  Page 183.1.6. Disable Polling 1. Please right click on top of connection manager and select   “OptionsDisable Polling”. 2. Connection manager will stop searching for available network.
  Page 193.1.7. PIN Management 1. Please right click on top of connection manager and select   “OptionsPIN ManagementPIN Information” to get PIN information. 2. Connection manager will pop out “PIN Information” window.  3. Please click “OK” button. 4. You also can enable PIN usage by right click on top of connection manager and select   “OptionsPIN ManagementEnable PIN Usage”.  5. Please input correct PIN code and click “OK” button.
  Page 203.1.8. Automatic Connect Mode 1. Please right click on top of connection manager and select   “OptionsAutomatic Connect Mode” to switch connection manager from manual connect mode to automatic connect mode. 2. Connection manager will automatically connect to network.
  Page 213.1.9. Device Location 1. For Quanta hostless device, please use “Technician PC” only. 2. Please right click on top of connection manager and select   “OptionsDevice LocationTechnician PC”. 3. Please set IP address to “10.0.0.1” and click “OK” button. 4. Connection manager will get information from Quanta hostless device.
  Page 223.1.10. Help 1. Please right click on top of connection manager and select   “HelpAbout”. 2. Connection manager will pop out a “LTE Card Info” message box.  3. It will show information of IMSI number, IMEI number, Supported Bands, Current firmware version, and System package version. 4. Please click “OK” button. 5. Please right click on top of connection manager and select   “HelpShow Versions”. 6. Connection manager will pop out a “Version info” message box.  7. It will show information of System release version, SWInfra release version, and Current firmware version. 8. Please click “OK” button.
  Page 233.1.11. Reset 1. Please right click on top of connection manager and select   “Reset”. 2. Connection manager will pop out a “” message box.
  Page 244. Diagnostic Tool 4.1. MsgView 1. Please open MsgView by clicking   StartProgramsAltair SemiconductorLTE ALT3100MsgView.  2. Please click “Start Logging” button to start message logging. 3. Please plug in Quanta device and wait a few seconds for device to be ready. 4. Once you find an issue, please stop testing and data logging, please save log file and send it to Quanta.
  Page 254.2. DbgView 1. Please open DbgView by clicking   StartProgramsAltair SemiconductorLTE ALT3100DbgView.  2. Please plug in Quanta device and wait a few seconds for device to be ready, and the DbgView will start data logging. 3. Please click “Save” button to save log to a file. 4. Once you find any issue, please stop testing and data logging, and please send this log file to Quanta.
  Page 265. Firmware Upgrade 5.1. Image Burn Tool 1. Please click   StartProgramsAltair SemiconductorLTE ALT3100HLVUSBImage Burn Tool.  2. Please check “U-Boot Env”. 3. Please check “U-Boot”. 4. Please check “Linux”. 5. Please check “File System”. 6. Please check “NVM”. 7. Please click “Start” button to start firmware upgrade process.  8. Please click “YES (Y)” button.
  Page 279. It will show message “Waiting for device reset …”. 10. The easiest way to reset device is to power cycle device (i.e. to take out and plug in device). 11. If you are doing remote firmware upgrade process, please follow the following procedure to reset device. 12. Please open device manager and find network interface of Quanta device “Remote NDIS based Internet Sharing Device #”. 13. Please disable this network interface by right click on it. 14. Please enable this device again.  15. Please find your Gadget Serial COM port number (for example, COM112).
  Page 2816. Please open COM112 COM port (for example, open it by putty.exe) 17. Please select “Serial” as your “Connection type”. 18. Please fill in “COM112” as your “Serial line”. 19. Please click “Open” button to set up connection. 20. Please enter “at”. 21. Please check if it responds with “OK”. 22. Please enter “atz” AT command to reboot Quanta device. 23. After Quanta device reboots successfully, the “Image Burn Tool” will start to do firmware upgrade process. 24. Please make sure you Quanta device has finished the firmware upgrade process with “---- Finished ----“. 25. Please close “Image Burn Tool”. 26. Please take out and plug in Quanta device.
  Page 2927. In order to recover the original calibration data, please use ADCC tool.   28. After the device reboot successfully, please open “Altair Device Control Center” by clicking, StartProgramsAltair SemiconductorLTE ALT3100ADCC. 29. Please click “Open Connection” and wait for a few minutes. 30. Please click “BSP DB” tab. 31. Please select “Boot Parameters (Boot Bp). 32. Please select “From File”. 33. Please click Read DB and find the source DB and click “Open” button to read it.  34. Please click “Burn DB” button to start burning. 35. Please repeat this procedure to burn the other DBs.
  Page 306. OMA-DM 6.1. Mandatory Configuration 1. It’s necessary to configure Quanta device with the following parameters before you start OMA-DM testing. 2. It’s mandatory to configure Quanta device with the following parameters if your device is upgraded to new firmware. 3. Please make sure that the device is not connected to LTE network (i.e. offline from eNodeB) before you do any configuration. 4. Please open connection manager. 5. Please enter the following AT commands sequentially (Please refer section 3.1.2). AT%SETCFG="enable_test_mode","0" AT%SETCFG="vzw_mode","1" AT%SETACFG=ecm.Mode.VzwMode,true AT%SETACFG=ecm.Mode.VzwImsTestMode,false 6. Please check if it returns “OK”. 7. Please confirm your configuration by entering the following AT commands sequentially. AT%GETCFG="enable_test_mode" (it shall be “0”) AT%GETCFG="vzw_mode" (it shall be “1”) AT%GETACFG=ecm.Mode.VzwMode (it shall be “true”) AT%GETACFG=ecm.Mode.VzwImsTestMode (it shall be “false”)
  Page 316.2. How to Enable/Disable APN 1. Please make sure your device has disconnected from network. 2. If you would like to edit APN table, it’s necessary to telnet to embedded connection manager. (Please refer to section 3.1.1) 3. Please open command console. 4. Please key in “telnet 10.0.0.1” and press enter. 5. If you failed to telnet 10.0.0.1, please manually set your IP address to 10.0.0.133. 6. After successfully telnet to 10.0.0.1, please key in “cat /etc/config/APNTable” and press enter. 7. There are 4 APNs in table, and you can see its configurations, including NAME, IP_Type, P_CSCF and so on. 8. For example, if you would like to disable “VZWIMS” APN, please use the editor tool “vi” to edit this APNTable. 9. Therefore, please key in   “vi /etc/config/APNTable” and press enter.
  Page 3210. Please move cursor to Option Enabled “true”   11. Please modify this value to “false”. NOTE: If you are not familiar with vi commands, please refer to section 6.6 for more information. 12. Please enter “Shift+z” twice to save file. 13. Please key in “cat /etc/config/APNTable” and press enter. 14. Please check if “VZWIMS” APN is disabled. Option Enabled ‘false’ 15. Please enter “reboot” command to reboot device in order to take effect of the configuration. 16. You can also follow above procedures to enable/disable other APNs. NOTE: Please make sure to reboot device in order to take effect of your setting.
  Page 336.3. How to Modify OMA-DM Server URL 1. Please make sure your device has disconnected from network. 2. If you would like to edit OMA-DM server URL, it’s necessary to telnet to embedded connection manager. (Please refer to section 3.1.1) 3. Please open command console. 4. Please key in “telnet 10.0.0.1” and press enter. 5. If you failed to telnet 10.0.0.1, please manually set your IP address to 10.0.0.133. 6. Please key in “vi etc/config/service” and press enter. 7. Please modify the server URL to   ”ivzwmdmii.iot.motive.com” 8. Please enter “Shift+z” twice to save file. 9. Please key in “cat /etc/config/service” and check if the server URL is set up correctly.  10. Please key in “vi etc/config/vdmc/tree-motive.xml”   and press enter.  11. Please key in “/https” to search the server URL. 12. Please modify the server URL to   https://ivzwmdmii.iot.motive.com/southbound-connector/dm
  Page 3413. Please also check if port number is “443”. 14. Please enter “Shift+z” twice to save file.
  Page 356.4. How to Online Enable/Disable Internet APN 1. Please check if your device has connected to LTE network successfully. 2. If you would like to online enable/disable “INTERNET” APN (see NOTE), it’s necessary to enter specific AT command. NOTE: Online enable/disable “INTERNET” APN means it’s not mandatory to reboot device to take effect of “INTERNET” APN. Please note that this method is applicable to “INTERNET” APN only, and this configuration will be lost after device reboots. 3. If you enter “at%dpdnact=0” to disable “INTERNET” APN, the LTE connection will be lost. On the contrary, if you enter “at%dpdnact=1” to enable “INTERNET” APN, device will reconnect to LTE network.
  Page 366.5. How to Enable/Disable OMA-DM log 1. Please make sure your device has disconnected from network. 2. If you would like to enable/disable OMA-DM log, it’s necessary to telnet to embedded connection manager. (Please refer to section 3.1.1) 3. Please open command console. 4. Please key in “telnet 10.0.0.1” and press enter. 5. If you failed to telnet 10.0.0.1, please manually set your IP address to 10.0.0.133. 6. Please key in “vi etc/config/service” and press enter. 7. Please modify the value of DebugLevel to “debug”. 8. Please enter “Shift+z” twice to save file. 9. Please enter “reboot” command to reboot device.  10. Please enter “cat /tmp/vdm.log” and check OMA-DM logs.
  Page 376.6. How to Use VI editor Please google search “vi manual” or by clicking below URL directly. http://glaciated.org/vi/
  Page 38FCC Regulations:  This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two conditions:  (1)  This  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any interference received, including interference that may cause undesired operation.  This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio  communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular installation if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.  RF Exposure Information  This  Modular  Approval  is  limited  to  OEM  installation  for  mobile  and  fixed  applications  only.   The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging  duty  factor,  antenna  gain  and  cable  loss  must  satisfy  MPE  categorical  Exclusion Requirements of §2.1091.    The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.   The end user has no manual instructions to remove or install the device and a separate approval is required for  all  other  operating  configurations,  including  portable  configurations  with  respect  to  2.1093  and different antenna configurations.  Maximum antenna gains allowed for use with this device are 3.82 dBi for band 13 and 5.82 dBi for band 4. When the module is installed in the host device, the FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: HFS-LI172”.

Navigation menu