Psion 7535OEM186 HANDHELD COMPUTER WITH RFID User Manual 8000007 Book

Psion Inc HANDHELD COMPUTER WITH RFID 8000007 Book

Contents

users manual 1

 I SO 9001 CertifiedQuality Management System   7535-RFID Hand-Held    Computer User Manual December 10, 2003 Part No. 8000007.B
 © Copyright 2003 by Psion Teklogix Inc., Mississauga, Ontario This document and the information it contains is the property of Psion Teklogix Inc.,is issued in strict confidence, and is not to be reproduced or copied, in whole or inpart, except for the sole purpose of promoting the sale of Teklogix manufacturedgoods and services. Furthermore, this document is not to be used as a basis fordesign, manufacture, or sub-contract, or in any manner detrimental to the interestsof Psion Teklogix Inc. All trademarks are the property of their respective holders.
 Return-To-Factory Warranty Psion Teklogix warrants a return-to-factory warranty for a period of one year fromshipment. The warranty on Psion Teklogix manufactured equipment does not extendto any product that has been tampered with, altered, or repaired by any person otherthan an employee of an authorized Psion Teklogix service organization. See PsionTeklogix terms and conditions of sale for full details. Service When requesting service, please provide information concerning the nature of thefailure and the manner in which the equipment was used when the failure occurred.Type, model, and serial number should also be provided. Before returning anyproducts to the factory, call the Customer Services Group for a ReturnAuthorization number.  Support Services Psion Teklogix provides a complete range of product support services to its custom-ers. In North America, these services can be accessed through the Psion TeklogixHelpdesk. The Helpdesk coordinates repairs and training, helps you to troubleshootproblems over the phone and arranges for technicians or engineers to come to yoursite. For contact information and a listing of worldwide offices, please refer to Appendix A: Support Services And Worldwide Offices .  Disclaimer Every effort has been made to make this material complete, accurate and up-to-date.Teklogix Inc. reserves the right to make changes without notice and shall not beheld responsible for damages resulting from reliance on the material presented inthis manual.
 Psion Teklogix 7535 Hand-Held Computer User Manual I P ROGRAM  L ICENSE  A GREEMENTS Microsoft's End User License Agreement You have acquired a device (“DEVICE”) that includes software licensed by PsionTeklogix Inc. from Microsoft Licensing Inc. or its affiliates (‘MS”). Those installedsoftware products of MS origin, as well as associated media, printed materials, and“online” or electronic documentation (“SOFTWARE”) are protected by interna-tional intellectual property laws and treaties. The SOFTWARE is licensed, not sold.All rights reserved.IF YOU DO NOT AGREE TO THIS END USER LICENSE AGREEMENT(“EULA”), DO NOT USE THE DEVICE OR COPY THE SOFTWARE.INSTEAD, PROMPTLY CONTACT PSION TEKLOGIX INC. FOR INSTRUC-TIONS ON RETURN OF THE UNUSED DEVICE(S) FOR A REFUND.  ANYUSE   OF THE SOFTWARE, INCLUDING BUT NOT LIMITED TO USE ONTHE DEVICE, WILL CONSTITUTE YOUR AGREEMENT TO THIS EULA(OR RATIFICATION OF ANY   PREVIOUS CONSENT).GRANT OF SOFTWARE LICENSE.  This EULA grants you the followinglicense:• You may use the SOFTWARE only on the DEVICE.• NOT FAULT TOLERANT . THE SOFTWARE IS NOT FAULT TOLER-ANT. PSION TEKLOGIX INC. HAS INDEPENDENTLY DETER-MINED HOW TO USE THE SOFTWARE IN THE DEVICE, AND MS HAS RELIED UPON PSION TEKLOGIX INC. TO CONDUCT SUFFI-CIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUIT-ABLE FOR SUCH USE.• NO WARRANTIES FOR THE SOFTWARE.  THE SOFTWARE is pro-vided “AS IS” and   with all faults. THE ENTIRE RISK AS TO SATIS-FACTORY QUALITY, PERFORMANCE, ACCURACY, AND EFFORT (INCLUDING LACK OF NEGLIGENCE) IS WITH YOU. ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST
 License AgreementII Psion Teklogix 7535 Hand-Held Computer User Manual INFRINGEMENT.  IF YOU HAVE RECEIVED ANY WARRANTIES REGARDING THE DEVICE OR THE SOFTWARE, THOSE WARRAN-TIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON, MS.• Note on Java Support . The SOFTWARE may contain support for pro-grams written in Java. Java technology is not fault tolerant and is not designed, manufactured, or intended for use or resale as online control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communica-tion systems, air traffic control, direct life support machines, or weapons systems, in which the failure of Java technology could lead directly to death, personal injury, or severe physical or environmental damage. Sun Microsystems, Inc. has contractually obligated MS to make this disclaimer.• No Liability for Certain Damages.  EXCEPT AS PROHIBITED BY LAW, MS SHALL HAVE NO LIABILITY FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE OR PER-FORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PUR-POSE. IN NO EVENT SHALL MS BE LIABLE FOR ANY AMOUNT IN EXCESS OF U.S. TWO HUNDRED FIFTY DOLLARS (U.S.$250.OO). • Limitations on Reverse Engineering, Decompilation, and Disassembly.  You   may not reverse engineer, decompile, or disassemble the SOFTWARE, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation.• SOFTWARE TRANSFER ALLOWED BUT WITH RESTRICTIONS.  You   may permanently transfer rights under this EULA only as part of a per-manent sale or transfer of the Device, and only if the recipient agrees to this EULA. If the SOFTWARE is an upgrade, any transfer must also include all prior versions of the SOFTWARE.• EXPORT RESTRICTIONS.  You acknowledge that SOFTWARE is subject to U.S. export jurisdiction. You agree to comply with all applicable international and national laws that apply to the SOFTWARE, including the U.S. Export Administration Regulations, as well as end-user, end-use and destination restrictions issued by U.S. and other governments. For addi-tional information see http://www.microsoft.com/exporting/.
 Psion Teklogix 7535 Hand-Held Computer User Manual IIILicense Agreement Meetinghouse Data Communications, Inc. End User License Agreement End User License Agreement:ATTENTION: PLEASE READ THIS SOFTWARE LICENSE AGREEMENT("LICENSE") CAREFULLY BEFORE INSTALLATION. USE OF THE SOFT-WARE IS SUBJECT TO THE SOFTWARE LICENSE TERMS SET FORTHBELOW. USING THE SOFTWARE INDICATES YOUR ACCEPTANCE OFTHESE LICENSE TERMS. IF YOU DO NOT ACCEPT THESE LICENSETERMS, YOU MUST RETURN THE SOFTWARE FOR A FULL REFUND. IFTHE SOFTWARE IS SUPPLIED WITH ANOTHER PRODUCT, YOU MAYRETURN THE ENTIRE UNUSED PRODUCT FOR A FULL REFUND. Software License Terms:The following terms govern your use of the enclosed Software unless you have aseparate written agreement with Meetinghouse Data Communications, Inc. hereinalso known as “MDC”.License Grant:MDC grants you a non-exclusive and non-transferable license to Use one copy ofthe Software. "Use" means storing, loading, installing, executing or displaying theSoftware. “Software” means software, documentation and any fonts accompanyingthis License whether on disk, in read only memory, on any other media or in anyother form. You may not modify the Software or disable any licensing or controlfeatures of the Software. If the Software is licensed for "concurrent use", you maynot allow more than the maximum number of authorized users to Use the Softwareconcurrently. The Software is licensed as a "Shareware" version, on one computer only. You mayuse the Software distributed and licensed as Shareware on a trial basis only. Theshareware version of the Software may be distributed freely without any associatedfees to other parties who wish to try the software as long as the Software is distrib-uted within an exact copy of the original MDC self-extracting installation file. Inother words, nothing may be left out of the Shareware as distributed on MDC's website at http://www.mtghouse.com.
 License AgreementIV Psion Teklogix 7535 Hand-Held Computer User Manual All permanent licenses are prepaid and the Software is licensed to you by MDC.You own the media on which the Software is recorded but MDC and/or MDC’slicensor(s) retain title to the Software. The Software and any copies which thisLicense authorizes you to make are subject to this License.Permitted Uses and Restrictions:This License allows you to install and use the Software on a single computer at atime. This License does not allow the Software to exist on more than one computerat a time. You may make one copy of the Software in machine-readable form forbackup purposes only. The backup copy must include all copyright information con-tained on the original. Except as expressly permitted in this License, you may not, inwhole or part, decompile, reverse engineer, disassemble, modify, rent, lease, loan,sublicense, distribute or create derivative works based upon the Software, or trans-mit the Software over a network. You may not copy the Software onto any bulletinboard or similar system. You agree that you will not utilize any information obtainedfrom MDC or obtained or learned in the course of using the Software, to develop orimprove technology with similar functionality to the Software, nor will you directlyor indirectly assist any other party in doing so. You further agree that you will notseparate the various modules of the software for their different purposes, if any.High Risk Activities: The Software is not fault-tolerant and is not designed, manufactured or intended foruse or resale as on-line control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation orcommunication systems, air traffic control, direct life support machines, or weaponssystems, in which the failure of the Software could lead directly to death, personalinjury, or severe physical or environmental damage ("High Risk Activities").Accordingly, MDC and its suppliers specifically disclaim any express or impliedwarranty of fitness for High Risk Activities. You agree that MDC and its supplierswill not be liable for any claims or damages arising from the use of the Software insuch applications. Ownership:The Software is licensed, not sold. The Software is owned and copyrighted by MDCor its third party suppliers. Your license confers no title or ownership in the Softwareand is not a sale of any rights in the Software. You acknowledge such ownership andintellectual property rights and will not take any action to jeopardize, limit or inter-fere in any manner with MDC's or its suppliers' ownership of or rights with respect
 Psion Teklogix 7535 Hand-Held Computer User Manual VLicense Agreement to the Software. The Software is protected by copyright and other intellectual prop-erty laws and by international treaties. MDC's third party suppliers may protect theirrights in the event of any violation of these License Terms.Termination:Your rights under this License will terminate automatically without notice fromMDC if you fail to comply with any term(s) of this License. Upon termination, youmust immediately destroy the Software, together with all copies, adaptations andmerged portions in any form. U.S. Government Restricted Rights:The Software and documentation have been developed entirely at private expenseand are provided as "Commercial Computer Software" or "restricted computer soft-ware". They are delivered and licensed as "commercial computer software" asdefined in DFARS 252.227-7013 (Oct 1988), DFARS 252.211-7015 (May 1991) orDFARS 252.227-7014 (Jun 1995), as a "commercial item" as defined in FAR 2.101(a), or as "Restricted computer software" as defined in FAR 52.227-19 (Jun 1987)(or any equivalent agency regulation or contract clause), whichever is applicable.You have only those rights provided for such Software and Documentation by theapplicable FAR or DFARS clause or the MDC standard software agreement for theproduct. Export Law Assurances:You may not use or otherwise export or reexport the Software except as authorizedby United States law and the laws of the jurisdiction in which the Software wasobtained. In particular, but without limitation, the Software may not be exported orreexported (i) into (or to a national or resident of) any U.S. embargoed country or(ii) to anyone on the U.S. Treasury Department's list of Specially DesignatedNationals or the U.S. Department of Commerce's Table of Denial Orders. By usingthe Software, you represent and warrant that you are not located in, under control of,or a national or resident of any such country or on any such list.Limited Warranty on Media: (if applicable)MDC warrants the media on which the Software is recorded to be free from defectsin materials and workmanship under normal use for a period of ninety (90) daysfrom the date of original retail purchase. Your exclusive remedy under this para-graph shall be, at MDC's option, a refund of the purchase price of the product con-taining the Software or replacement of the Software which is returned to MDC or a
 License AgreementVI Psion Teklogix 7535 Hand-Held Computer User Manual MDC authorized representative with a copy of the receipt. THIS LIMITED WAR-RANTY AND ANY IMPLIED WARRANTIES ON THE MEDIA INCLUDINGTHE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE ARE LIMITED IN DURATION TO NINETY (90)DAYS FROM THE DATE OF ORIGINAL RETAIL PURCHASE. SOME JURIS-DICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIEDWARRANTY LASTS, SO THIS LIMITATION MAY NOT APPLY TO YOU. THELIMITED WARRANTY SET FORTH HEREIN IS EXCLUSIVE AND IN LIEUOF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED.LICENSOR SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES. THISLIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOUMAY ALSO HAVE OTHER RIGHTS WHICH VARY BY JURISDICTION.Disclaimer of Warranty on Software:You expressly acknowledge and agree that use of the Software is at your sole risk.The Software is provided "AS IS" and without warranty of any kind and MDC andMDC’s licensor(s) (for the purposes of warranty and liability, MDC and MDC'slicensor(s) shall be collectively referred to as "MDC") EXPRESSLY DISCLAIMALL WARRANTIES AND/OR CONDITIONS, EXPRESS OR IMPLIED,INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIESAND/OR CONDITIONS OF MERCHANTABILITY OR SATISFACTORYQUALITY AND FITNESS FOR A PARTICULAR PURPOSE AND NONIN-FRINGEMENT OF THIRD PARTY RIGHTS. LICENSOR DOES NOT WAR-RANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILLMEET YOUR REQUIREMENTS, OR THAT THE OPERATION OF THE SOFT-WARE WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTSIN THE SOFTWARE WILL BE CORRECTED. FURTHERMORE, LICENSORDOES NOT WARRANT OR MAKE ANY REPRESENTATIONS REGARDINGTHE USE OR THE RESULTS OF THE USE OF THE SOFTWARE ORRELATED DOCUMENTATION IN TERMS OF THEIR CORRECTNESS,ACCURACY, RELIABILITY, OR OTHERWISE. NO ORAL OR WRITTENINFORMATION OR ADVICE GIVEN BY LICENSOR OR AN LICENSORAUTHORIZED REPRESENTATIVE SHALL CREATE A WARRANTY OR INANY WAY INCREASE THE SCOPE OF THIS WARRANTY. SHOULD THESOFTWARE PROVE DEFECTIVE, YOU (AND NOT LICENSOR OR ANLICENSOR AUTHORIZED REPRESENTATIVE) ASSUME THE ENTIRECOST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. SOMEJURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WAR-
 Psion Teklogix 7535 Hand-Held Computer User Manual VIILicense Agreement RANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THETERMS OF THIS DISCLAIMER DO NOT AFFECT OR PREJUDICE THESTATUTORY RIGHTS OF A CONSUMER ACQUIRING LICENSOR PROD-UCTS OTHERWISE THAN IN THE COURSE OF A BUSINESS, NEITHER DOTHEY LIMIT OR EXCLUDE ANY LIABILITY FOR DEATH OR PERSONALINJURY CAUSED BY LICENSOR’S NEGLIGENCE.Limitation of Liability:UNDER NO CIRCUMSTANCES, EXCEPT TO THE EXTENT PROHIBITEDBY LOCAL LAW, INCLUDING NEGLIGENCE, SHALL LICENSOR, ITS SUB-SIDIARIES, AFFILIATES, OR SUPPLIERS BE LIABLE FOR ANY DIRECT,INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES(INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS) ARIS-ING OUT OF OR RELATING TO THIS LICENSE, THE USE, INABILITY TOUSE, OR THE RESULTS OF USE OF THE SOFTWARE, WHETHER BASED INWARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, ANDWHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.In no event shall MDC's total liability to you for all damages exceed the price paidfor the license to use the Software, regardless of the form of the claim.Government End Users:If the Software is supplied to the United States Government, the Software is classi-fied as "restricted computer software" as defined in clause 52.227-19 of the FAR.The United States Government's rights to the Software are as provided in clause52.227-19 of the FAR.Controlling Law and Severability:This License shall be governed by the laws of the United States and the State ofNew Hampshire. As to any dispute relating to this License or the Software, you fur-ther agree to jurisdiction and venue in the Federal and State Courts located in theState of New Hampshire. If for any reason a court of competent jurisdiction findsany provision, or portion thereof, to be unenforceable, the remainder of this Licenseshall continue in full force and effect.Acknowledgement:Your use of any software produced by MDC is based only on your acknowledge-ment that you have read this License, understand it, and agree to be bound by itsterms and conditions.
 License AgreementVIII Psion Teklogix 7535 Hand-Held Computer User Manual MDC Acknowledgments:This product includes software developed by MDC and its licensors. This productincludes software developed by the OpenSSL Project for use in the OpenSSL Tool-kit (http://www.openssl.org/)". This product includes cryptographic software writtenby Eric Young (eay@cryptsoft.com). This product includes software written by TimHudson (tjh@cryptsoft.com).Complete Agreement:This License constitutes the entire agreement between the parties with respect to theuse of the Software and supersedes all prior or contemporaneous understandingsregarding such subject matter. No amendment to or modification of this License willbe binding unless in writing and signed by MDC.NOTE: EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW, THESEWARRANTY TERMS DO NOT EXCLUDE, RESTRICT, OR MODIFY, ANDARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICA-BLE TO THE LICENSE OF THE SOFTWARE TO YOU.Meetinghouse Data Communications, Inc.150 Greenleaf Avenue, Unit FPortsmouth, NH 03801Revised 8/12/2002
 Psion Teklogix 7535 Hand-Held Computer User Manual i T ABLE   OF  C ONTENTS Program License Agreements ..............................I Approvals And Safety Summary ...........................xiii Chapter 1:  Introduction 1.1 About This Manual ............................31.2 Text Conventions .............................41.3 About The 7535 Hand-Held Computer ..................51.3.1 Features...............................51.3.2 The 7535 Hand-Held Computer ..................71.3.3 Regulatory Labels .........................9 Chapter 2:  Basic Checkout 2.1 Preparing The 7535 For Operation ....................132.1.1 Equipment You Need To Get Started ...............132.1.2 Charging The Battery .......................132.1.3 Attaching Carrying Accessories ..................132.1.3.1 Attaching The Hand Strap ................142.1.3.2 Attaching The Pistol Grip ................152.2 Powering Up The 7535 And Configuring The Radio ...........162.2.1 Installing The Battery And Switching The 7535 On........172.2.3 Assigning An IP Address .....................242.2.4 Name Servers Tab .........................252.2.5 Advanced Features .........................262.2.5.1 Rearranging Preferred Networks ............262.2.5.2 Deleting A Preferred Network..............272.2.5.3 Changing Network Properties ..............272.3 Checking The Scanner ..........................272.4 Using Microsoft® ActiveSync® To Work With Files...........27
 Contentsii Psion Teklogix 7535 Hand-Held Computer User Manual 2.5 Calibrating The Touchscreen ......................282.6 Resetting The 7535 Hand-Held .....................28 Chapter 3:  Getting To Know Your 7535 3.1 Features Of The 7535 ..........................313.2 The Battery................................323.2.1 Battery Safety ...........................323.2.2 Removing And Installing The Battery Pack ...........323.2.3 Charging The Battery .......................333.3 Switching The 7535 Hand-Held On And Off ..............343.4 The Keyboard ..............................353.4.1 Modifier Keys...........................353.4.1.1 Activating Modifier Keys................363.4.1.2 Locking Modifier Keys.................363.4.2 The Keys .............................363.4.3 The 58-Key Keyboard ......................373.4.4 The 36-Key Keyboard ......................383.4.5 The Keypad Backlight ......................403.5 The Display ...............................403.5.1 Adjusting The Display Backlight.................403.5.2 Adjusting The Contrast ......................413.5.3 Calibrating The Touchscreen ...................413.6 7535 Indicators..............................423.6.1 LEDs ...............................423.6.1.1 Charge LED ......................433.6.1.2 Radio Traffic LED ...................443.6.1.3 Scan LED........................443.6.1.4 User Application LED .................443.6.2 Onscreen Indicators........................453.6.3 Audio Indicators .........................473.6.3.1 Adjusting The Beeper Volume .............483.7 Internal Scanners.............................483.7.1 Scanning Techniques .......................493.7.2 Scan LED Indicators .......................493.7.3 Troubleshooting..........................503.7.4 Operating One Dimensional (1D) Internal Laser Scanners....503.7.5 Operating Internal PDF Laser Scanners .............51
 Psion Teklogix 7535 Hand-Held Computer User Manual iiiContents 3.7.6 Operating Internal Two Dimensional (2D) Imager Scanners . . .513.8 Connecting & Disconnecting Tethered Peripherals............523.9 Monitoring The Battery And Maximizing Run Time ...........533.9.1 Storing Batteries ..........................553.10 Monitoring The Network Connection...................553.11 Uploading Data In A Docking Station ..................563.12 General Maintenance ...........................563.12.1 Caring For The Touchscreen....................563.12.2 Cleaning The 7535 .........................57 Chapter 4:  Working With Windows CE 4.1 Navigating In Windows CE And Applications ..............614.1.1 Navigating Using A Touchscreen And Stylus ...........614.1.2 Navigating Using The Keyboard..................624.2 Working With Files, Folders And Programs ...............634.3 The Startup Desktop............................644.3.1 The Desktop Icons .........................654.3.2 The Taskbar ............................664.3.2.1 Using The Taskbar ....................664.3.2.2 Customizing The Taskbar ................674.4 The Start Menu ..............................684.4.1 The Desktop ............................684.4.2 Security Settings ..........................694.4.3 The System Tray ..........................704.4.4 The Task Manager .........................714.4.5 Cycle Tasks.............................714.4.6 Power Info .............................714.4.7 Programs ..............................724.4.8 Settings ...............................734.4.9 Run .................................744.4.10 Shutdown..............................754.5 Using A Dialogue Box ..........................76 Chapter 5:  Configuration 5.1 Remote Desktop Connection .......................835.2 Pocket PC Compatibility .........................83
 Contentsiv Psion Teklogix 7535 Hand-Held Computer User Manual 5.3 The Control Panel ............................835.4 Control Panel Icons ...........................845.5 Basic Setup................................885.5.1 Display Properties.........................885.5.1.1 Display Contrast ....................885.5.1.2 Display Backlight ...................895.5.1.3 Display Appearance ..................915.5.2 Keyboard Properties .......................925.5.2.1 Key Repeat .......................925.5.2.2 Keyboard Backlight ..................935.5.2.3 Keyboard One Shot Modes...............945.5.2.4 Keyboard Macro Keys .................955.5.2.5 Unicode Mapping ...................975.5.3 Volume And Sound Properties ..................995.5.3.1 Volume Adjustments ..................995.5.4 Power Management Properties ..................1005.5.4.1 Battery Capacity ....................1005.5.4.2 Power Saving Schemes.................1015.5.4.3 Suspend Threshold ...................1025.5.4.4 Charger Details .....................1035.5.5 Stylus Properties .........................1035.5.5.1 Setting Double-Tap Sensitivity.............1045.5.5.2 Touchscreen Calibration ................1045.5.6 Certificate Assignment ......................1055.7 Scanner Properties Setup ........................1185.7.1 Scanner Options..........................1185.7.2 Bar Codes .............................1215.7.2.1 Code 39 Settings ....................1225.7.2.2 Code 128 Settings ...................1245.7.2.3 EAN 13 Settings ....................1255.7.2.4 EAN 8 .........................1265.7.2.5 UPC And EAN Settings ................1275.7.2.6 UPC A Settings.....................1275.7.2.7 UPC E Settings .....................1275.7.2.8 Codabar.........................1285.7.2.9 Code 93.........................1285.7.2.10 Code 11.........................128
 Psion Teklogix 7535 Hand-Held Computer User Manual vContents 5.7.2.11 Interleaved 2 of 5 ...................1295.7.2.12 MSI Plessey ......................1295.7.2.13 Discrete 2 of 5 .....................1295.7.2.14 IATA 2 of 5 ......................1305.7.2.15 Postal: Australian ...................1305.7.2.16 Postal: Japanese ....................1305.7.2.17 Postal: Korean .....................1305.7.2.18 Postal: PlaNET.....................1315.7.2.19 Postal: PostNET ....................1315.7.2.20 Postal: Royal Mail ...................1315.7.2.21 2D DataMatrix .....................1315.7.2.22 2D Maxicode......................1315.7.2.23 2D PDF-417 ......................1315.7.2.24 2D Micro PDF-417 ..................1325.7.2.25 2D QR Code ......................1325.7.2.26 2D RSS Code .....................1325.7.2.27 Aztec ..........................1325.7.3 Translations ...........................1325.8 SNMP (Simple Network Management Protocol) Setup ........1345.8.1 Contact Tab............................1355.8.2 Communities Tab ........................1365.8.2.1 Adding A Community .................1375.8.2.2 Modifying A Community Setting ...........1385.8.2.3 Removing An Existing Community ..........1385.8.3 Trap Destination Tab.......................1395.8.3.1 Enabling Authentication TRAPS ...........1395.8.3.2 Adding A Destination .................1395.8.3.3 Changing A Destination ................1405.8.3.4 Removing A Trap Destination .............1405.8.4 Permitted Hosts Tab .......................1415.8.4.1 Adding A Host .....................1415.8.4.2 Changing A Host....................142 Chapter 6:  Tekterm Application 6.1 The Tekterm Application ........................1476.2 Additional Keyboard Functions .....................1476.2.1 Function Keys And Softkeys...................1476.2.1.1 Function Keys .....................1476.2.1.2 Softkey Function Keys.................1486.2.2 Macro Keys............................149
 Contentsvi Psion Teklogix 7535 Hand-Held Computer User Manual 6.3 Keyboard Modes.............................1506.3.1 View Mode ............................1506.3.1.1 Changing Font Sizes ..................1506.3.1.2 Panning The Screen Contents .............1506.3.1.3 Exiting View Mode ...................1516.3.2 Using The Task Manager To Switch Between Applications. . .1526.4 The Tekterm Status Area.........................1536.5 TESS Emulation .............................1546.5.1 Configuration ...........................1546.5.2 Working With Multiple Sessions .................1546.5.3 The Field Types..........................1546.5.4 IBM 5250 Emulation Keys ....................1556.5.5 Data Entry.............................1556.5.5.1 TESS Edit Modes And Cursor Movement .......1566.5.5.2 <DEL> Key Behaviour In TESS ............1576.5.5.3 <BKSP> Key Behaviour In TESS ...........1586.5.6 TESS Status Message.......................1596.5.7 Lock Messages ..........................1606.5.8 Control Commands ........................1606.5.9 Resetting A TESS Session ....................1606.5.10 The Local Menu .........................1616.5.11 Selecting Another Host Computer ................1616.5.12 Queuing Mode ..........................1626.6 ANSI Emulation .............................1626.6.1 Configuration ...........................1626.6.2 Sending Data To The Host ....................1636.6.3 Psion Teklogix Keyboard And VT220 Equivalent Keys.....1636.6.4 Block Mode (Local Editing) ...................1646.6.5 Working With Sessions......................1656.6.5.1 Establishing A New Session ..............1656.6.5.2 Listing Sessions And Moving To Other Sessions . . .1656.6.5.3 Closing A Session ...................1656.6.5.4 Printing A Screen....................1666.6.5.5 Smart Echo – Disabling ................1666.8 The Tekterm Startup Display Menu ...................1686.9 Working With Menus ..........................169
 Psion Teklogix 7535 Hand-Held Computer User Manual viiContents 6.9.1 Using The Keyboard To Navigate Through Menus .......1706.9.1.1 Sub-Menus.......................1706.9.1.2 Numeric Parameters ..................1706.9.1.3 Y/N Parameters ....................1716.9.1.4 Alpha Parameters ...................1716.9.1.5 String Entry Parameters ................1716.9.2 Using The Touchscreen To Navigate Through Menus .....1736.9.2.1 Sub-Menus.......................1736.9.2.2 Numeric Parameters ..................1746.9.2.3 Y/N Parameters ....................1746.9.2.4 Alpha Parameters ...................1746.9.2.5 String Entry Parameters ................1746.9.3 Saving Changes To Parameters .................1756.9.4 Retrieving Default Parameter Values ..............1756.10 Resetting The 7535 Hand-Held Computer ...............1756.11 The Parameters Menu ..........................1766.11.1 Security Settings .........................1766.12 Display Options .............................1776.13 More Parameters ............................1776.15 System Parameters ...........................1806.15.1 Keyboard .............................1816.15.1.1 Macro Control Panel..................1816.15.1.2 Indicators........................1826.15.1.3 Softkeys ........................1826.15.1.4 Ctrl Panel .......................1826.15.2 Audio ...............................1836.15.3 Power Mgmt Ctrl Panel .....................1846.15.4 Security..............................1856.15.4.1 Default Mode .....................1856.15.4.2 User Level Options ..................1856.15.4.3 Sup. Password .....................1866.15.4.4 Allow Teklogix ....................1866.16 Scanner Control Panel..........................1876.17 View Manager..............................1876.17.1 Split Screen............................1886.17.1.1 Splitting And Displaying Screens ...........1896.17.1.2 Moving Between Split Screens ............1906.17.1.3 Toggling Between Full & Split Screens ........190
 Contentsviii Psion Teklogix 7535 Hand-Held Computer User Manual 6.17.1.4 Using The Asterisk As A Wild Card ..........1906.17.2 Custom Characters (Unicode™) .................1916.17.2.1 Creating A Unicode™ Character............1916.17.2.2 Displaying The Unicode™ Pop-up Window......1926.18 Applications ...............................1946.18.1 ANSI Settings...........................1956.18.1.1 Host Conn .......................1966.18.1.2 Screen..........................1996.18.1.3 Xmit Modes ......................2026.18.1.4 Kbd Modes .......................2066.18.1.5 Edit Modes .......................2096.18.1.6 Serial ..........................2106.18.1.7 Host Char Set......................2106.18.1.8 Anchor View ......................2116.18.2 TESS Settings...........................2126.18.2.1 Host Conn. .......................2136.18.2.2 Screen..........................2146.18.2.3 Characters .......................2166.18.2.4 Tests ..........................2186.18.2.5 Features.........................2196.18.2.6 Scanner .........................2236.18.2.7 Fields ..........................2246.18.2.8 Anchor View ......................2276.18.2.9 Emulation........................2276.19 Ports– Tether And Console........................2356.19.1 Tether And Console Port Peripheral Options...........2356.19.2 Tether And Console Port Parameter Settings...........2366.19.3 Tether And Console Port Scan-See Parameters .........2396.19.3.1 Scan-See Sub-Menu – Mapping The Viewport ....2396.19.3.2 Scan-See Keyboard Mapping .............2446.20 Network .................................2446.20.1 Network Ctrl Panel Settings ...................2456.20.2 802.IQ v2 .............................245 Chapter 7:  Peripheral Devices & Accessories 7.1 External Bar Code Readers .......................2517.1.1 PowerScan™ Standard, LR and XLR Bar Code Scanners....2517.1.2 Entering Data With The Bar Code Reader ............2517.2 The 7535 Battery.............................251
 Psion Teklogix 7535 Hand-Held Computer User Manual ixContents 7.2.1 Lithium-Ion Battery Safety Precautions .............2527.3 Important Charger Safety Instructions .................2537.4 Chargers .................................2547.5 Gang Charger ..............................2547.5.1 Installation ............................2557.5.2 Operator Controls ........................2557.5.3 Charge Indicators.........................2567.5.4 Charging Batteries ........................2567.5.5 Troubleshooting .........................2577.5.5.1 Excessive Charge Duration ..............2577.5.5.2 Indicator Flashing Red.................2577.5.5.3 Power LED Does Not Light Up ............2577.5.5.4 Indicator Does Not Light When Battery Installed. . . 2587.6 Combo Charger .............................2587.6.1 Installation ............................2587.6.2 Operator Controls ........................2597.6.3 Using the Combo Charger With The 7535............2597.6.4 Charging The Spare Battery ...................2597.6.5 Charge Indicators.........................2607.6.6 Troubleshooting .........................2607.7 Combo Dock ..............................2617.7.1 Installation ............................2617.7.2 Using The Combo Dock .....................2617.7.3 Network Access .........................2617.7.4 Troubleshooting .........................2627.8 Quad Dock ...............................2627.8.1 Installation ............................2627.8.2 Indicators And Controls .....................2637.8.3 Using The Quad Dock ......................2637.8.4 Network Access .........................2637.8.4.1 Network Addressing ..................2637.8.5 Battery Charging .........................2637.8.6 Troubleshooting .........................2647.8.6.1 Network Link Unsuccessful ..............2647.8.6.2 7535 LED Does Not Light When Docked.......2647.9 Portable Docking Module (PDM)....................264
 Contentsx Psion Teklogix 7535 Hand-Held Computer User Manual 7.11 The 7535 Picker Cradle .........................2687.11.1 Picker Cradle Mounting Recommendations ...........2697.11.1.1 Mounting Template...................2697.11.2 Wiring Guidelines ........................2707.11.3 Using The Picker Cradle .....................2707.11.4 Maintaining The Picker Cradle ..................2707.11.5 Powered Cradle Installation In High Voltage Vehicles .....2717.11.5.1 Extreme Wet Environments ..............2717.11.6 Powered Cradle Installation ...................2727.11.6.1 Wiring Vehicle Power To The Cradle .........2737.11.7 The Port Replicator ........................274 Chapter 8:  Specifications 8.1 7535 Hand-Held Computer Specifications ...............2778.2 RFID Specifications ...........................2798.3 Bar Code Scanning............................2798.3.1 Internal Scanners .........................2798.3.2 Internal Scanner Port .......................2808.3.3 External Scanners .........................2808.4 Internal Scanner Specifications .....................2818.4.1 SE1200 High Performance & Long Range Specs ........2818.4.2 SE1200 Advanced Long Range & SE2223 PDF Specs .....2828.4.3 Decode Zones ...........................2848.5 External Scanner Specifications .....................2848.5.1 PowerScan™ LR and XLR Industrial Scanner Specs ......2848.5.2 PowerScan™ Standard Range Scanner Specs ..........2878.6 Lithium-Ion Battery Pack ........................288 Appendix A:  Support Services And Worldwide Offices A.1 Support Services .............................A-1A.1.1 Canada and USA: Technical Support and Repair Services . . .A-1A.1.2 International Support.......................A-1 Appendix B:  Port Pinouts B.1 7535 Tether Port Pinout .........................B-1
 Psion Teklogix 7535 Hand-Held Computer User Manual xiContents B.2 Docking Station Connector .......................B-1B.3 Battery Contacts.............................B-2 Appendix C:  USB Setup Application C.1 USB Setup................................C-1C.1.1 Launching The Application ...................C-1C.1.2 Pre-Installation: Updating usbstor.inf And wceusbsh.inf ....C-2C.1.3 Installation: Installing The 7535 As a Device On Your PC . . . C-4C.1.4 Post Installation .........................C-5
 Psion Teklogix 7535 Hand-Held Computer User Manual xiiiAPPROVALS AND SAFETY SUMMARYDeclaration Of ConformityProduct: 7535 Hand Held Micro-computer with Portable Docking ModuleApplication of Council R&TTE Directive:  1999/5/EECDirective(s): EMC Directive: 89/336/EECLow Voltage Directive: 73/23/EECConformity Declared  Article 3.1a (Health): EN 60950: 2000 to Standards: Article 3.1b (EMC): EN 301 489-17: v1.1.1; 09-2000Article 3.2 (RF Spectrum): EN 300 328-2: v 1.1.1; 07 2000EN 55022: 1998 + Am 1, Class B;EN 61000-3-2; EN 61000-3-3EN 55024:1998;EN 61000-4-2; ±4kV CD; ±8kV ADEN 61000-4-3; 3V/m, 80-1000 MHzEN 61000-4-4; ±1kV Power linesEN 61000-4-5; ±1kV Differential modeEN 61000-4-6; 3VRMS, 150kHz-80MHzEN 61000-4-11; AC Mains PortsManufacturer: PSION TEKLOGIX INC.2100 Meadowvale BoulevardMississauga, Ontario, Canada L5N 7J9Year of Manufacture: 2003Manufacturer’s Address PSION TEKLOGIX S.A.in the European La Duranne; 135 Rue Rene Descartes; BP 421000Community: 13591 Aix-En-ProvenceCedex 3; FranceType of Equipment: Information Technology EquipmentEquipment Class: Commercial and Light IndustrialI the undersigned hereby declare that the equipment specified above conforms to the above directives and standards.Manufacturer: Rob WilliamsVice President of EngineeringPsion Teklogix Inc. OntarioLegal Representative Domique BincklyVice President International SalesPsion Teklogix S.A. France
Approvals And Safety Summaryxiv Psion Teklogix 7535 Hand-Held Computer User ManualFCC DECLARATION OF CONFORMITY (DoC)Applicant’s Name & Address: PSION TEKLOGIX2100 Meadowvale Blvd.Mississauga, OntarioCanada L5N 7J9Contact Person: Iain RoyTelephone No.: (905) 813-9900US Representative’s Name & Address: 1810 Airport Exchange Blvd., Suite 500Erlanger, KY, 41018, USAContact Person: Joe MusgraveTelephone No.: (859) 372-4106Equipment Type/Environment: Computing Devices Trade Name / Model No.:  7535 Hand Held Micro-computer with Portable Docking ModuleYear of Manufacture:  2003Standard(s) to which Conformity is Declared:The 7535 Hand Held Micro-computer with Portable Docking Module, supplied by Psion Teklogix, has been tested and found to comply with FCC PART 15, SUBPART B - UNINTENTIONAL RADIATORS, CLASS B COMPUTING DEVICES FOR HOME & OFFICE USE.I, the undersigned, hereby declare that the equipment as tested is representative within manufacturing tolerance to units.Applicant Legal Representative in U.S.Signature SignatureRob Williams                                          Joe Musgrave                            Full Name Full NameVice President of Engineering                V.P. Global Solutions, Americas    Position PositionMississauga, Ontario, Canada               Erlanger, KY 41018, USA              Place PlaceJuly 4, 2003                                            July 4, 2003                                   Date Date
Psion Teklogix 7535 Hand-Held Computer User Manual xvApprovals And Safety SummaryThis equipment complies with Class B Part 15 of the FCC rules.Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interfer-ence that may cause undesired operation. Changes or modifications not expressly approved by Psion Teklogix, the partyresponsible for compliance, may void the user's authority to operate the equipment.1. FCC Information to Users For Class B Unintentional Radiators:This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to Part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residential instal-lation. This equipment generates, uses, and can radiate radio frequency energyand, if not installed and used in accordance with the instruction manual, maycause harmful interference to radio communications. However, there is no guaran-tee that interference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, which can bedetermined by turning the equipment off and on, the user is encouraged to try tocorrect the interference by one of more of the following measures:• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.2. Warning to Users Warning: Changes or modifications not expressly approved by Psion Teklogix Inc. could void the user's authority to operate the equipment.
Approvals And Safety Summaryxvi Psion Teklogix 7535 Hand-Held Computer User ManualLASER WARNINGSFor your own safety, it is critical that you comply with the following warnings:CAUTIONDo not look into the laser beam or point the beam at people or animals.CAUTIONUsing controls or adjustments, or performing procedures other than thosespecified herein may result in hazardous radiation exposure.CAUTIONThe use of optical instruments with this product will increase eye hazard.This product contains a laser scanner that emits less than 1.2 mW maximum radiantpower at a wavelength of 650nm or 680nm. This product complies with 21 CFR1040.10, 1040.11 and DIN EN 60825-1: 2001, and is classified as a Class 2 laserproduct. The SE1200 ALR has an maximum radiated power less than 1.4 mW; according toEN 60825-1: 2001 it is classified as a Class 3B laser product.DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHEREOperating Psion Teklogix equipment where explosive gas is present mayresult in an explosion.DO NOT REMOVE COVERS OR OPEN ENCLOSURESTo avoid injury, the equipment covers and enclosures should only beremoved by qualified service personnel. Do not operate the equipmentwithout the covers and enclosures properly installed.
Psion Teklogix 7535 Hand-Held Computer User Manual xviiApprovals And Safety SummaryCAUTION!Danger of explosion if a 7535 battery is incorrectly handled, charged,disposed of or replaced. Replace only with the same or equivalent typerecommended by the manufacturer. Dispose of used batteries according tothe instructions described in “Lithium-Ion Battery Safety Precautions” onpage 252. Carefully review all battery safety issues.VORSICHT!Explosiongefahr bei unsachgemäßem Austausch der Batterie Ersatz nurdurch denselben oder einen vom Hersteller empfohlenen gleichwertigenTyp. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
Psion Teklogix 7535 Hand-Held Computer User Manual 1INTRODUCTION 111.1  About This Manual ..............................31.2  Text Conventions ...............................41.3  About The 7535 Hand-Held Computer ....................51.3.1  Features .................................51.3.2  The 7535 Hand-Held Computer .....................71.3.3  Regulatory Labels ............................9
Psion Teklogix 7535 Hand-Held Computer User Manual 3Chapter 1: IntroductionAbout This Manual1.1  About This ManualThis manual describes how to configure, operate and maintain the Psion Teklogix 7535 hand-held computer.Chapter 1: Introductionprovides a basic overview of the 7535 hand-held.Chapter 2: Basic Checkoutdescribes the steps required to get the 7535 ready for operation. Chapter 3: Getting To Know Your 7535describes the 7535 features and outlines how to charge and maintain the battery. This chapter also provides a description of the keyboard, how to navigate in Microsoft® Windows® CE, how to use the internal scanner, and so on.Chapter 4: Working With Windows CEdescribes the Microsoft® Windows® CE desktop and how to use it. This chapter also outlines the basics of moving around a Windows CE window, selecting and opening icons, files, folders and working with a Windows dialogue box.Chapter 5: Configurationprovides a description of the Windows CE Control Panel and how to use itto configure the 7535, along with the scanners attached to the hand-held, and so on.Chapter 6: Tekterm Applicationdescribes TESS and ANSI operations. This chapter also provides descriptions of the Tekterm parameters.Chapter 7: Peripheral Devices & Accessoriesdescribes the peripherals and accessories available for your 7535 hand-held.Chapter 8: Specificationsdetails radio, hand-held computer and battery specifications.Appendix A: Support Services And Worldwide Officesprovides the helpdesk phone number at the Mississauga, Ontario, Canada office and details the support services available. This appendix also lists the world-wide office addresses and phone numbers.Appendix B: Port Pinoutsincludes 7535 pinouts.
Chapter 1: IntroductionText Conventions4Psion Teklogix 7535 Hand-Held Computer User Manual1.2  Text ConventionsNote: Notes highlight additional helpful information.Important: These statements provide particularly important instructions or additional information that is critical to the operation of the equipment.Warning: These statements provide critical information that may prevent physical injury, equipment damage or data loss.
Psion Teklogix 7535 Hand-Held Computer User Manual 5Chapter 1: IntroductionAbout The 7535 Hand-Held Computer1.3  About The 7535 Hand-Held ComputerThe 7535 is a ruggedized hand-held personal computer, running the Microsoft® Windows® CE.net operating system. It is intended for use in commercial and light industrial applications with a focus on real time wireless data transactions. All possible bar code input methodologies are supported by one of the variety of scanners available. Optimization for specific operational environments is supported with a wide range of peripheral options and carrying accessories.1.3.1  Features• Rugged design:- sealed from water and dust to IP54 (light rain) rating.- withstands multiple drops of up to 6.5 feet onto concrete.• Large 240 x 320 portrait mode display that is available in colour or black and white with or without a touchscreen• Automatic backlighting for both the display and the keypad.- automatic backlight and contrast control.- daylight readable screen.• Processor and memory:- Intel PXA255 400Mhz CPU with 32 MB FLASH and 64 MB RAM standard.• Microsoft® Windows® CE.net operating system• Application software:- Internet Explorer for CE.- Tekterm terminal emulation.• Ergonomic keyboard designed to accommodate left- and right-handed use.• Two keyboard formats available:- 58-key with 6 function keys (standard).- 36-key large button with 10 function keys.- keypads feature EL backlight for visibility in low-light conditions.• Wireless communication:- Compact FLASH slot normally equipped with an IEEE 802.11b 11 Mbps 2.4GHz Wi-Fi radio.
Chapter 1: IntroductionFeatures6Psion Teklogix 7535 Hand-Held Computer User Manual- standard antenna integrated onto radio card.- optional high performance internal antenna available.- Bluetooth SD I/O radio.• Expansion slot:- SD I/O slot that supports extra FLASH memory (up to 512 MB)  • Programming environment:-HTML- .net Compact framework- Java, Visual C++• Bar code applications:- internal 1D and 2D scan engines.- internal CMOS image capture scan engine.- supports decoded and undecoded tethered scanners.
Psion Teklogix 7535 Hand-Held Computer User Manual 7Chapter 1: IntroductionThe 7535 Hand-Held Computer1.3.2  The 7535 Hand-Held ComputerFigure 1.1 7535 With 58-Key Keyboard
Chapter 1: IntroductionThe 7535 Hand-Held Computer8Psion Teklogix 7535 Hand-Held Computer User ManualFigure 1.2 7535 Docking PortFigure 1.3 Tether PortFigure 1.4 Scanner Window
Psion Teklogix 7535 Hand-Held Computer User Manual 9Chapter 1: IntroductionRegulatory Labels1.3.3  Regulatory LabelsFigure 1.5 Laser Warning LabelsFigure 1.6 Radio Labels
Chapter 1: IntroductionRegulatory Labels10 Psion Teklogix 7535 Hand-Held Computer User ManualFigure 1.7 Manufacturer’s LabelWarning: Using controls or adjustments or performing procedures other than those specified herein may result in hazardous radiation exposure.
Psion Teklogix 7535 Hand-Held Computer User Manual 11BASIC CHECKOUT 222.1  Preparing The 7535 For Operation .....................132.1.1  Equipment You Need To Get Started .................132.1.2  Charging The Battery .........................132.1.3  Attaching Carrying Accessories ...................132.1.3.1  Attaching The Hand Strap ..................142.1.3.2  Attaching The Pistol Grip ..................152.2  Powering Up The 7535 And Configuring The Radio ............162.2.1  Installing The Battery And Switching The 7535 On .........172.2.3  Assigning An IP Address .......................242.2.4  Name Servers Tab...........................252.2.5  Advanced Features ..........................262.2.5.1  Rearranging Preferred Networks ..............262.2.5.2  Deleting A Preferred Network ................272.2.5.3  Changing Network Properties ................272.3  Checking The Scanner ...........................272.4  Using Microsoft® ActiveSync® To Work With Files............272.5  Calibrating The Touchscreen ........................282.6  Resetting The 7535 Hand-Held .......................28
Psion Teklogix 7535 Hand-Held Computer User Manual 13Chapter 2: Basic CheckoutPreparing The 7535 For Operation2.1  Preparing The 7535 For OperationTypically, 7535 hand-helds are configured at the factory and arrive ready for use. Although the 7535 is equipped with an internal Compact Flash and SD I/O slot, these slots are not intended for user modification. If a device needs to be changed or added in these slots, contact qualified Psion Teklogix personnel. Refer to Appendix A: Support Services And Worldwide Offices for the service number closest to you.2.1.1  Equipment You Need To Get StartedYou’ll need:• A 7535 compatible battery charger, docking station or portable docking module (PDM) with power supply.• An operating wireless network (if you are not operating the equipment in batch mode).• A medium Phillips head screwdriver.2.1.2  Charging The BatteryImportant: The 7535 uses a high capacity Lithium-Ion battery. It is critical that you review the battery safety guidelines in “Lithium-Ion Battery Safety Precautions” on page 252 before charging the battery. Batteries shipped from the factory are not charged. They must be fully charged prior to use. Full capacity may not be reached until at least 5 full charge/discharge cycles have been performed. 7535 batteries can be charged using a gang charger or the 7535 internal charger. When using the internal charger, a suitable power source is required. All chargers and docking stations are described in Chapter 7: Peripheral Devices & Accessories beginning on page 254. 2.1.3  Attaching Carrying AccessoriesPsion Teklogix recommends that a carrying accessory – a hand strap, pistol grip or shoulder strap – be installed on the 7535 before use.If your hand-held is not fitted with a hand strap or pistol grip, you can install either using the carrying accessory kit supplied. You’ll need:• A Phillips head screwdriver.
Chapter 2: Basic CheckoutAttaching The Hand Strap14 Psion Teklogix 7535 Hand-Held Computer User ManualImportant: Do not use adhesives such as Loctite to secure the screws on the carrying accessories. These chemicals may damage the plastic casing.2.1.3.1 Attaching The Hand StrapNote: A Phillips head screwdriver is required.Two Phillips head screws are provided with the hand strap. • Attach the strap to the two threaded inserts located at the back of the 7535 near the top of the unit. Figure 2.1 Attaching The Hand Strap
Psion Teklogix 7535 Hand-Held Computer User Manual 15Chapter 2: Basic CheckoutAttaching The Pistol Grip• Stretch the handstrap toward the base of the 7535, and hook the bottom of the handstrap into the slot near the base of the battery pack.Figure 2.2 Hooking The Hand Strap To The 75352.1.3.2 Attaching The Pistol GripNote: A Phillips head screwdriver is required.The pistol grip is attached to the back of the 7535 using the four threaded inserts in the upper part of the 7535 casing. Four black #4-40 Phillips head screws are provided with this accessory. Note: Prior to installation, make sure the trigger mechanism is securely snapped into the pistol grip body and that the trigger operates properly.
Chapter 2: Basic CheckoutPowering Up The 7535 And Configuring The Radio16 Psion Teklogix 7535 Hand-Held Computer User Manual• Position the pistol grip so that it fits snugly over the back of the unit and the inserts on the back of the 7535 align with the holes in the pistol grip. Figure 2.3 Attaching The Pistol Grip• Using a Phillips screwdriver, securely fasten the pistol grip to the back of the 7535.2.2  Powering Up The 7535 And Configuring The RadioNote: Psion Teklogix offers a Portable Docking Module (PDM) along with its power supply to help speed the checkout and confirmation process for your 7535. The PDM can power your hand-held with or without a battery installed in the 7535. Refer to Chapter 7: Peripheral Devices & Accesso-ries beginning on page 249 for more information about this accessory.
Psion Teklogix 7535 Hand-Held Computer User Manual 17Chapter 2: Basic CheckoutInstalling The Battery And Switching The 7535 On2.2.1  Installing The Battery And Switching The 7535 OnIf you are not using a docking station or PDM:• Slide the charged battery with the contoured plastic facing you into the 7535. Click the battery into place.Figure 2.4 Installing The BatteryNote: If you are using a docking station, you can insert an uncharged battery, dock the unit and switch it on. If you are using a PDM, you can configure your unit without a battery, with a charged battery or with an uncharged battery.If you are using a hand strap:• Hook the bottom of the hand strap into the slot at the base of the battery.To switch the 7535 on:• Press and hold down the <ENTER/ON> key for at least one second.• When all four LEDs flash orange, release the <ENTER/ON> button.A splash screen displaying the Psion Teklogix logo and the Microsoft® Windows® CE. net logo appears. When Windows® CE has successfully loaded, the startup desktop is displayed.Note: The screen may go blank for a few seconds after the splash screen loading bar reaches the end. This is part of the normal Windows CE cold boot process. The desktop is displayed after a few moments.
Psion Teklogix 7535 Hand-Held Computer User Manual 25Chapter 2: Basic CheckoutName Servers Tab• Press the <DOWN> arrow key to highlight Specify an IP address.• Press the <TAB> key to move from field to field, and type an IP, Subnet Mask and Default Gateway address. Press <ENTER> to save your information.2.2.4  Name Servers TabNote: If DHCP is enabled, name server addresses are assigned automatically.• In the $NETWLAN1 Settings window, press the <TAB> key followed by the <LEFT> arrow key to display the IP Information tab.• In the IP Information tab, highlight the Configure... button, and press <ENTER>.• Press the <TAB> key followed by the <RIGHT> arrow key to display the Name Servers tab.Figure 2.13 Name Servers TabThe DNS and WINS fields in the Name Servers tab allow you to specify additional WINS and DNS resolvers. The format for these fields is ###.###.###.###.
Chapter 2: Basic CheckoutAdvanced Features26 Psion Teklogix 7535 Hand-Held Computer User Manual2.2.5  Advanced FeaturesTo display the Advanced Wireless Settings dialogue box:• Highlight the Advanced... button in the Wireless Information tab and press <ENTER>.This window lists the available preferred networks. Figure 2.14 Advanced Settings2.2.5.1 Rearranging Preferred NetworksThe 7535 attempts to connect with the networks listed in this dialogue box in sequence, beginning at the top of the list. If you need to rearrange this list of networks – move networks up and down in the list:• Press the <TAB> key to move the cursor into the networks list.• Use the <UP> or <DOWN> arrow keys to highlight the network that you want to move up or down in the list.• To move the highlighted item in the list upward or downward, press <TAB> to highlight the Up or Down button, and press <ENTER>.
Psion Teklogix 7535 Hand-Held Computer User Manual 27Chapter 2: Basic CheckoutDeleting A Preferred Network2.2.5.2 Deleting A Preferred NetworkTo delete a network from this list:• Press the <TAB> key to highlight the networks list.• Use the <UP> or <DOWN> arrow keys to highlight the network that you want to remove.• Highlight the Delete button, and press <ENTER>.2.2.5.3 Changing Network PropertiesTo change the properties of an existing preferred network:• Highlight the network that you want to modify.• Press <TAB> to highlight the Properties button, and press <ENTER>.• Make any necessary changes in the Wireless Properties dialogue box, and press <ENTER> to save the changes.2.3  Checking The ScannerIf your 7535 is equipped with an internal scanner, it will successfully decode most 1D bar codes as delivered. Press the SCAN button and check for a valid decode on any UPC bar code. If desired, set the “Dot Time” parameter to zero in the ‘Teklogix Scanners’ applet in the Control Panel to turn off the default aiming dot.Performance is improved if you disable all unneeded bar codes under the ‘Bar Codes’ dialogue screen. Review “Scanner Properties Setup” on page 118 for details about bar codes.2.4  Using Microsoft® ActiveSync® To Work With FilesActiveSync® – Microsoft PC connectivity software – can be used to connect the 7535 to PCs running this software. By connecting the 7535 to a PC with a cable and running ActiveSync on the PC, you can:• View 7535 files from Windows Explorer.• Drag and drop files between the 7535 and the PC in the same way that you would between PC drives.• Back up 7535 files to the PC, then restore them from the PC to the hand-held again, if needed, and so on.Note: You’ll need the USB setup utility to configure the .ini file. For information about this USB application, refer to Appendix C: USB Setup Application.
Chapter 2: Basic CheckoutCalibrating The Touchscreen28 Psion Teklogix 7535 Hand-Held Computer User ManualTo install ActiveSync, follow the step-by-step instructions provided with the program’s setup wizard. Refer to the following website for details: http://www.microsoft.com/windowsmobile/resources/downloads/pocketpc/activesync35.mspx2.5  Calibrating The TouchscreenIf your 7535 is equipped with a touchscreen, it will need to be calibrated. Refer to “Calibrating The Touchscreen” on page 41 for details.2.6  Resetting The 7535 Hand-HeldImportant: Because Psion Teklogix cannot guarantee what has been saved (registry) after a reset, this should be considered as a last resort.To reset the 7535:• Press and hold down the <BLUE> key and the <ENTER/ON> key simulta-neously for a minimum of six seconds.A reset results in a complete reboot of the unit. All RAM memory contents are lost. The contents of the flash memory and memory card may be preserved, but Psion Teklogix cannot guarantee. However, you should keep in mind that When the 7535 is reset, the screen displays the Psion Teklogix and Microsoft® Windows® CE.net splash screen before displaying the startup desktop.Note: You do not need to reset your 7535 after configuring the radio.
Psion Teklogix 7535 Hand-Held Computer User Manual 29GETTING TO KNOW YOUR 7535 333.1  Features Of The 7535 ............................313.2  The Battery .................................323.2.1  Battery Safety.............................323.2.2  Removing And Installing The Battery Pack .............323.2.3  Charging The Battery .........................333.3  Switching The 7535 Hand-Held On And Off ................343.4  The Keyboard ................................353.4.1  Modifier Keys.............................353.4.1.1  Activating Modifier Keys ..................363.4.1.2  Locking Modifier Keys ...................363.4.2  The Keys ...............................363.4.3  The 58-Key Keyboard ........................373.4.4  The 36-Key Keyboard ........................383.4.5  The Keypad Backlight ........................403.5  The Display .................................403.5.1  Adjusting The Display Backlight ...................403.5.2  Adjusting The Contrast ........................413.5.3  Calibrating The Touchscreen .....................413.6  7535 Indicators ...............................423.6.1  LEDs .................................423.6.1.1  Charge LED .........................433.6.1.2  Radio Traffic LED ......................443.6.1.3  Scan LED ..........................443.6.1.4  User Application LED ....................443.6.2  Onscreen Indicators..........................453.6.3  Audio Indicators ...........................473.6.3.1  Adjusting The Beeper Volume ................483.7  Internal Scanners ..............................483.7.1  Scanning Techniques .........................493.7.2  Scan LED Indicators .........................493.7.3  Troubleshooting............................503.7.4  Operating One Dimensional (1D) Internal Laser Scanners......503.7.5  Operating Internal PDF Laser Scanners ...............513.7.6  Operating Internal Two Dimensional (2D) Imager Scanners.....51
Chapter 3: Getting To Know Your 753530 Psion Teklogix 7535 Hand-Held Computer User Manual3.8  Connecting & Disconnecting Tethered Peripherals .............523.9  Monitoring The Battery And Maximizing Run Time ............533.9.1  Storing Batteries............................553.10  Monitoring The Network Connection ...................553.11  Uploading Data In A Docking Station ...................563.12  General Maintenance............................563.12.1  Caring For The Touchscreen.....................563.12.2  Cleaning The 7535..........................57
Psion Teklogix 7535 Hand-Held Computer User Manual 31Chapter 3: Getting To Know Your 7535Features Of The 75353.1  Features Of The 7535Figure 3.1 Front Of 7535Figure 3.2 Back Of 7535Ambient Light SensorTether PortDocking Port7535 ScreenSound PortStylus(Pointing Tool) Scanner WindowBattery PackTether Port
Chapter 3: Getting To Know Your 7535The Battery32 Psion Teklogix 7535 Hand-Held Computer User Manual3.2  The BatteryThe 7535 hand-held operates with a Lithium-Ion battery pack. Preparing the hand-held unit for operation requires that a battery pack be charged and installed in the unit.3.2.1  Battery SafetyImportant: Before attempting to install, use or charge the battery pack, it is critical that you review and follow the important safety guidelines in the section entitled “Lithium-Ion Battery Safety Precautions” beginning on page 252.3.2.2  Removing And Installing The Battery PackNote: TURN OFF THE 7535 HAND-HELD BEFORE REMOVING THE BATTERY PACK. If you do not turn the hand-held off before removing the battery, it may be necessary to reboot the unit. Any active sessionswill be lost.Removing The Battery Pack• If your 7535 is equipped with a hand strap, unhook it from the base of the battery.• Press down the release tab at the top of the battery, and slide the battery out.
Psion Teklogix 7535 Hand-Held Computer User Manual 33Chapter 3: Getting To Know Your 7535Charging The BatteryInstalling The Battery PackTo install the battery pack:• Slide the battery pack with the contoured plastic facing you into the 7535. Click the battery into place.Figure 3.3 Installing The Battery Pack• If your computer is equipped with a hand strap, insert the hook at the end of the hand strap into the slot at the base of the battery.3.2.3  Charging The BatteryImportant: FOR DETAILED INFORMATION about 7535 chargers and docking stations, refer to Chapter 7: Peripheral Devices & Acces-sories beginning on page 249. For battery safety, refer to “Lith-ium-Ion Battery Safety Precautions” beginning on page 252.All batteries must be charged before use. The 7535 battery can be charged with a variety of chargers. These include: • 6-Gang Charger (Model #HU3006) – charges up to six Lithium-Ion batter-ies at one time.• Portable Docking Module (Model #HU4001 or HU1005 and HU3220 or HU3220) – charges the 7535 battery (with the battery installed in the unit).• Combo Charger (Model #HU3002) – a desktop charger that charges the 7535 internal battery along with a spare battery pack.
Chapter 3: Getting To Know Your 7535Switching The 7535 Hand-Held On And Off34 Psion Teklogix 7535 Hand-Held Computer User Manual• Combo Docking Station (Model #HU4002) – operates as both a charger and a docking station. Operating as a charger, both the battery installed in the computer and a spare battery can be charged simultaneously. • Quad Docking Station (Model #HU4004) – can charge the battery of up to four 7535s inserted in the docking station while transferring data through an Ethernet connection.• Powered Cradle (Model #HU1000, HU1010) – can charge the 7535 with the battery installed in the hand-held.It can take from 1.5 to 4 hours to charge a battery. The 7535’s intelligent charging system protects the battery from over-charging by terminating the charge process when the battery is at maximum capacity.Note: Refer to “Monitoring The Battery And Maximizing Run Time” on page 53 for additional information about the 7535 battery.Important: To avoid damaging the battery, chargers will not begin the charge process until the battery temperature is between 0˚C (32˚F) and 39˚C (102˚F). If the battery is too hot or cold, the battery status LED flashes yellow and the charge is suspended. Refer to Table 3.1, “Charge LEDs” on page 43 for details.3.3  Switching The 7535 Hand-Held On And OffSwitching On The 7535• Press and hold down the <ENTER/ON> key for at least one second. • When all four LEDs flash orange, release the <ENTER/ON> button.A splash screen displaying the Psion Teklogix logo and the Microsoft® Windows® CE. net logo appears followed by the startup desktop.Note: If the 7535 is in suspend state, pressing <ENTER/ON> key ‘wakes’ the unit from this state. The screen in which you were working before the computer entered suspend state is displayed.
Psion Teklogix 7535 Hand-Held Computer User Manual 35Chapter 3: Getting To Know Your 7535The KeyboardSwitching Off The 7535Important: Keep in mind that turning off the 7535 does not result in a complete reboot; rather, the unit enters a power-saving, “suspend” state. When the 7535 is turned on from suspend state, operation resumes within a few seconds. To switch off the 7535:• Press the <BLUE> key, and then press the <ENTER/ON> key.Important:  If the word ‘BLUE’ is displayed in uppercase in the taskbar area at the bottom of the screen, this key is locked “on” – the 7535 will not switch off. Press the <BLUE> key again to unlock it; then press <BLUE> <ENTER/ON> to switch the 7535 off.If, however, you’ve disabled the “Blue Key” in the ‘One Shot’ dia-logue box (see “Keyboard One Shot Modes” on page 94), the 7535 can be turned off even when the <BLUE> key is locked ‘on’.3.4  The KeyboardThe 7535 offers two types of keyboard layouts – a 58-key keyboard and a 36-key, large button keyboard. Most of the keys on these keyboards operate much like a desktop computer. Where a key or key function is not consistent with the PC keyboard, the differences are noted. The <BLUE> and <ORANGE> modifier keys provide access to additional keys and system functions. These functions are colour coded in orange and blue print above the keyboard keys.3.4.1  Modifier KeysThe <SHIFT>, <CTRL>, <ALT>, <BLUE> and <ORANGE> keys are modifier keys. Pressing a modifier key changes the function of the next key pressed. For example, on a 58-key keyboard, a square bracket is printed in orange print above the <4> key. Pressing the <ORANGE> key followed by the <4> key displays a square bracket rather than the number 4.
Chapter 3: Getting To Know Your 7535Activating Modifier Keys36 Psion Teklogix 7535 Hand-Held Computer User ManualThe <SHIFT>, <CTRL> and <ALT> keys operate much like a desktop keyboard except that they are not chorded (two keys held down simultaneously). The modifier key must be pressed first followed by the key whose function you want modified.3.4.1.1 Activating Modifier KeysWhen a modifier key is pressed once, it is displayed in lowercase letters in the taskbar at the bottom of the 7535 screen. For example, if the <CTRL> key is pressed, ctrl key is displayed at the bottom of the unit screen. Once the next key is pressed, the modifier key becomes inactive and disappears from the taskbar.3.4.1.2 Locking Modifier KeysWhen a modifier key is pressed twice, it is ‘locked’ on. A ‘locked’ modifier key is displayed in uppercase letters in the taskbar. For example, pressing the <BLUE> key twice locks it on – it is displayed as BLUE KEY in the taskbar at the bottom of the computer screen.The locked modifier key will remain active until it is pressed a third time to unlock or turn it off. Once a modifier key is unlocked (pressed a third time), the uppercase representation at the bottom of the screen is no longer displayed.Note: The locking function of the <ORANGE> and <BLUE> keys can be dis-abled so that pressing either of these keys once will lock the keys ‘on’. If you disable the ‘One Shot’ function of either of these keys, pressing the <BLUE> and/or <ORANGE> key once will lock the key ‘on’. Pressing the same key a second time will unlock or turn it ‘off’. Refer to “Keyboard One Shot Modes” on page 94 for details.3.4.2  The KeysThe <SHIFT> KeyThe <SHIFT> key is used to display uppercase alpha characters and provide access to the symbols above the numeric keys.The Arrow KeysThe Arrow keys move the cursor around the screen in the direction of the arrow – up, down, left and right. The cursor is the flashing box or underline character that indicates where the next character you type will appear.
Psion Teklogix 7535 Hand-Held Computer User Manual 37Chapter 3: Getting To Know Your 7535The 58-Key KeyboardThe <BKSP/DEL> KeyThe <BKSP> key (sometimes referred to as destructive backspace) moves the cursor one character to the left, erasing the incorrectly entered key stroke. The <DEL> key (<BLUE> <BKSP>) erases the character at the cursor position.The <CTRL> And <ALT> KeyThe <CTRL> and <ALT> keys modify the function of the next key pressed and are application dependent. The <TAB> KeyTypically, the <TAB> key moves the cursor to the next field to the right or downward.The <ESC> KeyGenerally, this key is used as a keyboard shortcut to close the current menu, dialogue box or activity and return to the previous one.The <SPACE> KeyPressing this key inserts a blank space between characters. In a Windows dialogue box, pressing the <SPACE> key enables (√) or disables a checkbox.The <SCAN> KeyPressing the <SCAN> key – the yellow key with the star-burst scan symbol on it – activates the scanner beam while pressed. For units that do not have internal scanners, this key is inoperable.3.4.3  The 58-Key KeyboardIn addition to alphanumeric keys that are directly accessible on the keyboard (no key combination is required) and the keys described in this chapter, the 58-key keyboard also provides function keys and macro keys. Function keys <F1> through <F24> can be used with the CE operating system or another application. The additional function keys – <F25> through <F30> along with the macros are not used as part of the Windows CE operating system. All function keys and macro keys can be custom defined for each application. The Tekterm application utilizes these keys. Refer to “Additional Keyboard Functions” on page 147 for details about Tekterm keys.
Chapter 3: Getting To Know Your 7535The 36-Key Keyboard38 Psion Teklogix 7535 Hand-Held Computer User Manual3.4.4  The 36-Key KeyboardOn 36-key 7535s, all alpha characters are printed on the unit plastic in orange typeface above the numeric keys. To access an alpha character, you must first press the <ORANGE> key and then press the numeric key above which the alpha character you want to type is printed. Because the alpha keys on a 36-key keyboard are laid out much like the letters on a telephone – generally in groups of three letters per numeric key – you need to take a few extra steps to access the alphabetic characters. The examples in this section help illustrate how to access alpha characters.Choosing A Single Alpha CharacterNote: Keep in mind that the following examples assume that ‘One Shot’ is enabled for the <ORANGE> key. Refer to “Keyboard One Shot Modes” on page 94 for details.The examples below illustrate how to access A, B and C, all of which are printed in orange characters above the numeric key, <2>.To choose the letter ‘a’:• Press the <ORANGE> key, and press the numeric key <2>.To choose the letter ‘b’:• Press the <ORANGE> key twice to lock it ‘on’, and press <2> twice.• Press the <ORANGE> key again to unlock or turn it off.To choose the letter ‘c’:• Press the <ORANGE> key twice to lock it ‘on’.• Press <2> three times, and then • Press the <ORANGE> key again to unlock or turn it off.Creating Uppercase LettersTo display a capital letter:• Press the <ORANGE> key and then the <SHIFT> key before typing the alpha character.
Psion Teklogix 7535 Hand-Held Computer User Manual 39Chapter 3: Getting To Know Your 7535The 36-Key KeyboardChoosing More Than One Alpha Character From The Same KeyIf you need to choose more than one alpha character from a single key, you’ll need to press the ‘Accept’ key between alpha selections. The ‘Accept’ key is presented as an arrow ⇒ symbol above the ‘0’ (zero) key. Pressing this key signals the 7535 to display the alpha character you’ve chosen and await the next selection from the same key. For example, suppose you want to type the letters ‘a’, ‘b’ and ‘c’. These letters are all accessible from the numeric key, <2>.To type the letter ‘a’:• Press the <ORANGE> key twice to lock it ‘on’, and then press the numeric key, <2>.• Press the ‘Accept’ key < ⇒> to indicate that the letter ‘a’ should be accepted and that another letter from the same key will be chosen.To type the letter ‘b’:• Press the <2> key twice.• Press < ⇒> to accept the letter ‘b’.To type the letter ‘c’:• Press the <2> key three times.When you have completed your alpha selections from this key, you can do one of the following:• If you want to choose additional alpha characters from another key(s), leave the <ORANGE> key ‘on’, and press the next numeric key that supports the alpha character you require.• If you do not want to choose any additional alpha characters, press <ORANGE> again to unlock or turn ‘off’ the key and end alpha selection.Choosing Multiple Alpha Characters From A Range Of KeysIf you plan on choosing alpha characters from a number of different keys, you are not required to press the ‘Accept’ < ⇒> key after each alpha selection. The < ⇒> key is only required when you are choosing more than one alpha character from the same key – e.g., ‘a’, ‘b’ and ‘c’ from the <2> key.
Chapter 3: Getting To Know Your 7535The Keypad Backlight40 Psion Teklogix 7535 Hand-Held Computer User ManualSuppose you want to type the letters ‘a’, ‘d’ and ‘g’. These alpha characters are accessed from the numeric keys <2>, <3> and <4>.• With the <ORANGE> key locked ‘on’ (press twice), press <2> to type the letter ‘a’.• Press <3> to type ‘d’, and press <4> to type the letter ‘g’.• To end alpha selection, press the <ORANGE> key a third time to unlock it.3.4.5  The Keypad BacklightThe intensity of the keypad backlight and the conditions under which this backlight is activated can be configured using the Keyboard icon in the Windows CE Control Panel. The behaviour of the keypad backlight is tailored in the Keyboard Properties dialogue box. Refer to “Keyboard Backlight” on page 93 for details about this option.Note: Keep in mind that this option may be restricted to supervisory use only.3.5  The Display7535s are equipped with display backlighting to improve character visibility in low light conditions. The backlight switches on when a key is pressed and the ambient light is below the set threshold. A light sensor on the front of the hand-held determines the ambient light level. On some displays, the contrast can also be adjusted to further improve character visibility.3.5.1  Adjusting The Display BacklightThe behaviour of the display backlight – the ambient light threshold below which the backlight will become active and the intensity of the backlight – can be specified in the Display Properties dialogue box in the Windows CE Control Panel.Note: Refer to “Display Backlight” on page 89 for details about the Display Properties dialogue box.
Psion Teklogix 7535 Hand-Held Computer User Manual 41Chapter 3: Getting To Know Your 7535Adjusting The Contrast3.5.2  Adjusting The ContrastNote: In addition to the manual adjustments described in this section, the dis-play contrast can also be adjusted using the Windows CE Control Panel. Refer to “Display Contrast” on page 88 for details about this dialogue box.The display contrast can be adjusted from the unit keyboard using the <BLUE> key and function keys <F1> and <F2>. Pressing <F1>   darkens the display, and pressing <F2>   lightens the display. Keep in mind that adjusting the contrast on a colour display is much less pronounced than on a monochrome display.To adjust the display contrast:• Press the <BLUE> key twice to lock it on, and then press <F1>  . to darken the display or <F2>  . to lighten the display.• Once you’ve successfully adjusted the display contrast, remember to press the <BLUE> key again to turn it ‘off’.3.5.3  Calibrating The TouchscreenIf your 7535 touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, use the Stylus Properties dialogue box in the Windows CE Control Panel to recalibrate the screen.• In the Control Panel, choose the Stylus icon to display the Stylus Properties window.Figure 3.4 Stylus Icon
Chapter 3: Getting To Know Your 75357535 Indicators42 Psion Teklogix 7535 Hand-Held Computer User Manual• Select the Calibration tab, and then choose the ‘Recalibrate’ button.Figure 3.5 Calibration Screen• Follow the directions on the calibration screen to calibrate the screen.3.6  7535 Indicators7535s use LEDs (Light Emitting Diode), onscreen messages and audio tones as indicators.3.6.1  LEDsThe 7535 is equipped with four tri-coloured LEDs. This section outlines what these LEDs indicate. Important: If an LED is illuminated in red, the operator should be cautious as this generally indicates an abnormal operating condition or active laser emission.
Psion Teklogix 7535 Hand-Held Computer User Manual 43Chapter 3: Getting To Know Your 7535Charge LEDFigure 3.6 Keyboard LEDs3.6.1.1 Charge LEDThe lower-right LED is reserved for internal charger/power status. This indicator is active even when the 7535 is inserted in a docking station (and in suspend mode) so that the charge status of the battery can be detected easily.*If the charge fails, refer to the charger troubleshooting sections in Chapter 7: Peripheral Devices & Accessories beginning on page 254 for helpful details.Table 3.1  Charge LEDsFunction Charge LED BehaviourExternal power not available. LED off.Fully charged to within 95% of charge capacity. LED displays solid green colour.Quick charge successfully completed to within 75% of charge capacity. LED flashes slow green.Charge in progress. LED displays solid yellow colour.Cell temperature out of range for charge. LED flashes yellow.Unable to charge battery. LED displays solid red colour.Charge circuit failure.* LED flashes fast red.*Radio TrafficScannerLEDLED ChargeLEDUserApplicationLED
Chapter 3: Getting To Know Your 7535Radio Traffic LED44 Psion Teklogix 7535 Hand-Held Computer User Manual3.6.1.2 Radio Traffic LEDThe upper-left LED on your 7535 flashes either orange or green to indicate when the radio transmits and receives data.Note: Keep in mind that while the standard 802.11b radio supports the trans-mit/receive LED, not all radios support this function.Table 3.2  Transmit and Receive LEDs3.6.1.3 Scan LEDSuccessful scans are indicated in two ways – with a scan LED and with an audio tone.Table 3.3  Scan LED3.6.1.4 User Application LEDThis indicator is available for user-loaded custom Windows CE applications. Refer to the 7535 SDK Manual for details about this LED. Neither Windows CE nor Tekterm use this LED.Function Radio Traffic LED BehaviourRadio Transmit LED flashes orange.Radio Receive LED flashes green.Function Scan LED BehaviourScan in progress LED displays solid red during scan.Successful scan LED displays solid green after decode. Off when scan ended.Unsuccessful scan LED flashes red.
Psion Teklogix 7535 Hand-Held Computer User Manual 45Chapter 3: Getting To Know Your 7535Onscreen Indicators3.6.2  Onscreen IndicatorsThe taskbar at the bottom of the screen displays a variety of system status indicators.Figure 3.7 TaskbarThis display changes dynamically, and only those icons that are applicable are displayed. For example, if a radio is not installed in your 7535, the radio signal icon is not displayed in the taskbar.Windows® Start ButtonIf you have a touchscreen, you can display the Start Menu by tapping on the Windows® Start button in the taskbar.
Chapter 3: Getting To Know Your 7535Onscreen Indicators46 Psion Teklogix 7535 Hand-Held Computer User ManualModifier Key Indicators<SHIFT>, <CTRL>, <ALT>, <BLUE> and <ORANGE> are modifier keys that have onscreen indicators to show when a key is active or locked. If a modifier key is pressed once to activate it, the key is displayed in the taskbar in lowercase characters – for example, pressing the <BLUE> key once displays blue key in the taskbar. If a modifier key is pressed twice, it is ‘locked on’ and the onscreen indicator is displayed in uppercase letters in the taskbar – for example, pressing <BLUE> twice displays BLUE KEY in the taskbar.Battery GaugeThe battery shaped icon displayed in the taskbar provides a visual indication of the remaining battery power. The icon acts as a meter that is either full, at three-quarter level, half, quarter level or empty.When the battery level is low – approximately 15 minutes from empty – a warning window pops up. When the battery power is completely depleted, a final warning window indicates that the 7535 will be powered down.If the 7535 is using external AC power, an AC icon is displayed in the taskbar.Battery ChargeThe battery charge icon is displayed in the taskbar when the 7535 hand-held battery is being charged.Radio Signal QualityIncreasing radio signal quality is represented by longer, filled bars within this icon.AC ConnectionFull75%50% 25% EmptyGood No RadioReception WeakReception Link
Psion Teklogix 7535 Hand-Held Computer User Manual 47Chapter 3: Getting To Know Your 7535Audio IndicatorsTethered DevicesWhen a peripheral is attached to the tether port and activated, an associated icon appears in the taskbar. The sample to the left indicates that a USB device is connected to the tether port.Docking DeviceWhen a 7535 is inserted in a docking station, charger or cradle, an associated icon appears in the taskbar.Security LevelSecurity levels can be set to limit user access to 7535 settings. In addition, applications can be restricted to prevent inadvertent changes.3.6.3  Audio IndicatorsThe 7535 beeper provides a variety of sounds and can be configured to emit a sound when a key is pressed, a keyboard character is rejected, scan input is accepted or rejected, an operator’s entry does not match in a match field or the battery is low. The volume function keys are located in the top row of the keyboard. The increase volume key is labelled with a plus symbol   and the decrease volume function key is labelled with a minus symbol  .Scanner RFID Serial Device Scan-SeeUSB DeviceGang Charger, Combo Charger & Combo Docking Station Quad Docking Station Power Cradle Portable Docking Module (PDM)
Chapter 3: Getting To Know Your 7535Adjusting The Beeper Volume48 Psion Teklogix 7535 Hand-Held Computer User Manual3.6.3.1 Adjusting The Beeper VolumeOn 58-key keyboards, the volume function keys are accessed by pressing <BLUE> <F5> and <F6>. On 36-key keyboards, the volume function keys are accessed by pressing <BLUE> < F3> and <F4>. To adjust the beeper volume:• Press the <BLUE> key twice to lock the key ‘on’ and then, press the increase volume function key   or the decrease volume  function key until the volume is meets your requirements. • Remember to press the <BLUE> key again to turn it ‘off’.3.7  Internal ScannersImportant: For detailed scanner specifications and decode zone tables, refer to “Internal Scanner Specifications” beginning on page 281.The scanner installed in your unit can be configured using the Scanner Properties dialogue box in the Control Panel.The 7535 can be equipped with a:• One dimensional (1D) internal laser scanner,• Internal PDF laser scanner, or a• Two dimensional (2D) internal imager scanner.It is critical that you review the warnings listed in “Laser Warnings” on page xvi in the Approvals and Safety section at the beginning of this manual before using any of the scanners described in this chapter. “Scanning Techniques” outlines the mechanics of a successful scan. In addition, review “Scan LED Indicators” on page 49 to better understand how to interpret whether or not a bar code has been successfully scanned. Finally, “Troubleshooting” on page 50 provides some helpful suggestions should the scan fail.
Psion Teklogix 7535 Hand-Held Computer User Manual 49Chapter 3: Getting To Know Your 7535Scanning Techniques3.7.1  Scanning TechniquesNote: The scanning techniques described here apply to internal and external scanners.• Hold the scanner at an angle. Do not hold it perpendicular to the bar code.•Do not hold the scanner directly over the bar code. In this position, light can reflect back into the scanner’s exit window and prevent a successful decode.• Scan the entire bar code. If you are using a 1D or PDF laser scanner, make certain that the scan beam crosses every bar and space on the bar code, including the margins on either end of the symbol.• If you are using a 2D imaging scanner, make certain the red, oval shaped framing mark is centered within the bar code you want to scan.• Hold the scanner farther away for larger bar codes.• Hold the scanner closer for bar codes with bars that are close together.3.7.2  Scan LED IndicatorsThe 7535 scanner LED (the lower-left LED) indicates whether or not your scan is successful. The LED behaves as follows:• Scan In Progress: scan LED displays solid red colour.• Successful Scan: scan LED displays solid green colour and turns off when the scan is ended.• Unsuccessful scan: scan LED flashes red.A bar code icon appears on the screen during a scan. While the scanner beam is active, the onscreen message states – SCANNING. If the scan is successful, the bar code data is displayed on the screen until the scan button (or pistol trigger) is released.
Chapter 3: Getting To Know Your 7535Troubleshooting50 Psion Teklogix 7535 Hand-Held Computer User Manual3.7.3  TroubleshootingIf the scanner is not working, investigate the following:• Is the 7535 on?• Check that the bar code symbology being scanned is enabled for the 7535 you are using. Check any other parameters that affect the scanning proce-dure or the bar code.• Check the bar code to make sure it is not damaged. Try scanning a different bar code to verify that the problem is not with the bar code.• Check that the bar code is within the proper range.• Does the hand-held display the warning without scanning? This suggests a hardware problem in the 7535.• Is the laser beam scanning across the bar code? • Once the scan beam has stopped, check the scanner window for dirt or fogging.3.7.4  Operating One Dimensional (1D) Internal Laser Scanners• Turn the 7535 on. Wait until the unit has booted up completely.Important: If an aiming dot is available on the installed scanner, the dot will be enabled for a configurable time period (including off), after which normal scanning begins. Refer to “Dot Time (msec)” on page 120 for details. Double-clicking the trigger will override the aiming delay and initiate an immediate scan. Note that the aiming dot is standard on long-range and high visibility internal scanners.• Aim at the bar code and press the scan key or the trigger. A scan beam and a warning indicator appear until a successful decode is achieved or six seconds have elapsed.
Psion Teklogix 7535 Hand-Held Computer User Manual 51Chapter 3: Getting To Know Your 7535Operating Internal PDF Laser Scanners3.7.5  Operating Internal PDF Laser ScannersThis scanner decodes PDF417 two-dimensional bar codes.• Turn the 7535 on. Wait until the unit has booted up completely.• Aim at the bar code and press the scan key or the trigger. The beam expands into a rectangle covering the bar code to properly scan it. The scan beam and a warning indicator are visible until a successful decode is achieved or three seconds have elapsed.3.7.6  Operating Internal Two Dimensional (2D) Imager ScannersAn imager scanner takes a snap shot of a single bar code or multiple bar codes (at one time). It can find a bar code regardless of its orientation – that is, even a bar code printed at a 45 degree angle to the 7535 will be decoded successfully. Note: When scanning multiple bar codes, ensure that all of the desired bar codes are within the field of view of the scanner. It is possible that even when all bar codes are within the field of view, not all of them may be decoded. Only successfully decoded bar codes are passed to the applica-tion program. The application program then issues a warning, asking that you scan the missing bar codes.When scanning a single bar code, ensure that only the desired bar code is within the field of view of the scanner.Because imager scanners generally have a shorter depth of field than laser scanners, some practise may be required to find the optimal distance from the types of bar codes being scanned. Although the imager includes illumination LEDs, ambient light will help the imager decode the bar codes, especially if the bar code is far from the 7535.Important: Keep in mind that the imager scanner is a camera, and the LED illumination is a flash. Glare can be an issue on reflective media such as plastic coated bar codes, just as glare is an issue for pho-tographers. When pointing at a shiny surface, either shift the bar code to the side or top, or angle the bar code so that the glare reflects away from the imager scanner.• Turn the 7535 computer on. Wait until the unit has booted up completely.• Aim at the bar code and press the scan key or the trigger.
Chapter 3: Getting To Know Your 7535Connecting & Disconnecting Tethered Peripherals52 Psion Teklogix 7535 Hand-Held Computer User Manual• When the scan button or trigger is pressed, a red, oval shaped light (the framing marker) is displayed. Centre the framing marker in the field – either in the centre of the bar code you want to scan or in the centre of the area in which multiple bar codes are to be scanned.Illumination LEDs will flash and a picture of the bar code(s) is taken.3.8  Connecting & Disconnecting Tethered PeripheralsTethered peripherals such as scanners and printers connect to the hand-held computer with a quick release, circular connector. When a peripheral is connected to the hand-held, the 7535 detects the peripheral and loads the necessary drivers for it. An icon in the taskbar at the bottom of the screen provides a visual representation of the peripheral and indicates that it is ready for operation.To attach the peripheral to the round, tether port on the side of the 7535:• Insert the barrel of the plug into the tether port and rotate slowly until it clicks into place. The red dot on the port and on the connector should be aligned.Figure 3.8 Attaching The Cable To The Tether Port
Psion Teklogix 7535 Hand-Held Computer User Manual 53Chapter 3: Getting To Know Your 7535Monitoring The Battery And Maximizing Run TimeTo remove the peripheral:• Grasp the shell of the plug, and pull it back gently to unlock and release the connector. Figure 3.9 Disconnecting The Tether CableImportant: Never attempt to disconnect a peripheral by pulling the connector by the wire. The connector is locked into place and can only be unlocked and removed by pulling back the plug shell.3.9  Monitoring The Battery And Maximizing Run TimeUnder normal operating conditions, fully charged batteries last for 10 hours. As Lithium-Ion batteries age, their capacity decreases gradually, and they are generally considered depleted after approximately 2 years of use (less than 60% of original capacity remaining). Keep in mind however that heavy usage or operating the 7535 at temperature extremes will shorten the battery life. Lithium-Ion batteries do not require conditioning cycles and the 7535 battery system (including chargers) requires no user interaction to maintain peak performance.
Chapter 3: Getting To Know Your 7535Monitoring The Battery And Maximizing Run Time54 Psion Teklogix 7535 Hand-Held Computer User ManualTo maximize the run time of your batteries, consider the following:• The display backlight is the largest drain on the battery. Try to keep its brightness as low as possible.• The hand-held is ‘event’ driven – that is, when the unit is not in use, it reverts to sleep mode (even when it appears to be running), saving battery power. Events include a key press, touchscreen taps and scan triggers. Power consumption is reduced if you avoid unnecessary events, and allow the unit to sleep as much as possible.• The 7535 battery is a ‘smart battery’ with built-in intelligence. The taskbar battery icon is a linear gauge used to estimate the remaining run time of the battery. It is important to note that the battery capacity icon displays quarter percentages of nominal capacity (the capacity of a new battery). An aged battery, even when fully charged, shows somewhat less capacity than nominal. Double-tapping on the battery icon displays a dialogue box that provides detailed information about the battery status and performance. If the remaining capacity indication seems inaccurate, the battery may need recal-ibration. Recalibration requires that the battery be fully charged, discharged and then charged again before use. If the battery is fully discharged and charged on a regular basis, recalibration should not be necessary. • When the hand-held is switched off, it goes into a low-power, suspend state but continues to draw a small amount of power from the battery. This should not be an issue unless the unit is left in suspend state for more than a week – in this case, the battery should be removed.• Batteries left unused for durations of more than one or two months should be fully charged, discharged and then charged again before use. This recali-brates the gas gauge and allows the internal electronics to determine the actual capacity of the battery.• The hand-held can determine when the useful life of the battery has expired and will notify the user. Chargers may reject batteries that have exceeded their lifespan.
Psion Teklogix 7535 Hand-Held Computer User Manual 55Chapter 3: Getting To Know Your 7535Storing Batteries3.9.1  Storing BatteriesLong term battery storage is not recommended. If storage is necessary:• Always try to use a ‘first-in first-out’ approach to minimize storage time.• Lithium-Ion batteries age much faster at elevated temperatures. Store bat-teries at temperatures between 0˚ C and 20˚C. • Always charge batteries to 40 to 60% before storing them. Batteries can be damaged by an over-discharge phenomenon that occurs when an empty battery is stored for a long period of time such that the cell voltage drops below a lower limit. • To minimize storage degradation, recharge stored batteries to 40 to 60% every 4 or 6 months to prevent over-discharge damage.• A ‘never used’ Li-Ion battery that has been stored for 3 years may have limited or no useful life remaining once put into service. Think of batteries as perishable goods.3.10  Monitoring The Network ConnectionIf your hand-held is equipped with a wireless LAN radio, it will typically associate with the nearest access point. The radio signal quality meter in the taskbar indicates the relative strength of the communication link. To access the radio signal icon from the keyboard:• Press <BLUE> <0> to display the Start Menu.• Choose System Tray from the menu.• Use the <LEFT> and <RIGHT> arrow keys to highlight the radio signal icon in the taskbar.• Press <ENTER> to display the wireless statistics box dialogue box.If you have a touchscreen:• Tap on the radio icon in the taskbar to display the wireless statistics dialogue box.Note: Moving in and out of the radio coverage area can have varying effects on a network session. At times, you may need to renew your connection by logging in again.
Chapter 3: Getting To Know Your 7535Uploading Data In A Docking Station56 Psion Teklogix 7535 Hand-Held Computer User Manual3.11  Uploading Data In A Docking StationThe Combo Docking and Quad Docking peripherals allow the 7535 to link to an Ethernet network. They are typically used to upload transaction data to a server computer when a radio link in not available. When a 7535 is properly inserted in a docking station, a dock icon is displayed in the taskbar at the bottom of the 7535 screen. The 7535 also detects the presence of the Ethernet network. Review the documentation provided with the user application installed in your 7535 before preforming data uploads.3.12  General Maintenance3.12.1  Caring For The TouchscreenThe top of the touchscreen is a thin, flexible polyester plastic sheet with a conductive coating on the inside. The polyester can be permanently damaged by harsh chemicals and is susceptible to abrasions and scratches. Using sharp objects on the touchscreen can scratch or cut the plastic, or crack the internal conductive coating.The chemicals listed below must not come into contact with the touchscreen:• mustard,• sodium hydroxide,• concentrated caustic solutions,• benzyl alcohol, and• concentrated miner acids.If the touchscreen is used in harsh environments, consider applying a disposable screen protector (PN HU6110). These covers reduce the clarity of the display slightly but will dramatically extend the useful life of the touchscreen. When they become scratched and abraded, they are easily removed and replaced.
Psion Teklogix 7535 Hand-Held Computer User Manual 57Chapter 3: Getting To Know Your 7535Cleaning The 75353.12.2  Cleaning The 7535Important: Do not immerse the unit in water. Dampen a soft cloth with mild detergent to wipe the unit clean.• Use only mild detergent or soapy water to clean the hand-held unit.• Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The 7535 has a plastic case that is susceptible to harsh chemicals. The plastic is partially soluble in oils, mineral spirits and gasoline. The plastic slowly decomposes in strong alkaline solutions.• To clean ink marks from the keypad and touchscreen, use isopropyl alcohol.
Psion Teklogix 7535 Hand-Held Computer User Manual 59WORKING WITH WINDOWS CE 444.1  Navigating In Windows CE And Applications ...............614.1.1  Navigating Using A Touchscreen And Stylus ............614.1.2  Navigating Using The Keyboard ...................624.2  Working With Files, Folders And Programs ................634.3  The Startup Desktop ............................644.3.1  The Desktop Icons ..........................654.3.2  The Taskbar ..............................664.3.2.1  Using The Taskbar ......................664.3.2.2  Customizing The Taskbar ..................674.4  The Start Menu ...............................684.4.1  The Desktop .............................684.4.2  Security Settings ...........................694.4.3  The System Tray ...........................704.4.4  The Task Manager ..........................714.4.5  Cycle Tasks ..............................714.4.6  Power Info ..............................714.4.7  Programs ...............................724.4.8  Settings ................................734.4.9  Run ..................................744.4.10  Shutdown ..............................754.5  Using A Dialogue Box ...........................76
Psion Teklogix 7535 Hand-Held Computer User Manual 61Chapter 4: Working With Windows CENavigating In Windows CE And Applications4.1  Navigating In Windows CE And ApplicationsGraphic user interfaces like Windows CE for portable devices and desktop Windows (2000, XP, etc.) utilize ‘point and click’ navigation. An equivalent keyboard shortcut is also available for every ‘point and click’ action.Windows CE supports the same ‘point and click’ user interface and keyboard shortcuts as desktop Windows with one difference – the ‘point and click’ action is accomplished using a touchscreen rather than a mouse. Actions can be performed using any combination of keyboard shortcuts or touchscreen tapping (provided your 7535 is equipped with a touchscreen).4.1.1  Navigating Using A Touchscreen And StylusNote: If the touch screen is not registering your screen taps accurately, the touchscreen may need recalibration. Refer to “Calibrating The Touch-screen” on page 41.A touchscreen is an optional feature. A 7535 equipped with a touchscreen has a stylus – a pointing tool that looks like a pen – stored in a slot at the top of the 7535. The stylus is used to select objects on the touchscreen.Note: To prevent damage to the touchscreen, use only the stylus (pen) supplied with your 7535.To open a file, launch an applet or open a folder:• Double-tap the stylus on the appropriate icon.
Chapter 4: Working With Windows CENavigating Using The Keyboard62 Psion Teklogix 7535 Hand-Held Computer User Manual4.1.2  Navigating Using The KeyboardIf your 7535 has a standard screen (rather than a touchscreen), choosing icons and navigating dialogue boxes, displaying the desktop, and so on requires keyboard input. If your unit has already been fully configured and your application is launched at startup, you’ll have little need for keyboard navigation. Table 4.1  Keyboard NavigationKeep in mind that unlike a desktop computer, the 7535 does not support key chording (pressing two keys at the same time). You must press one key followed by the next in sequence.Refer to “Working With Files, Folders And Programs” on page 63 for additional details about keyboard navigation.Operation Key or Key CombinationSwitch between active applications <ALT> <TAB>Open task manager <ALT> <ESC>Move the cursor Arrow keysOpen file, folder or icon <ENTER>Exit & Save <ENTER>Close/Exit & Do Not Save <ESC>Navigate Dialogue Boxes<TAB>To move cursor up <SHIFT> <TAB>To display the contents of the next ‘tab’ in a dialogue box <CTRL> <TAB>Select Radio Button/Press Button <SPACE>Go to Start Menu <BLUE><0>
Psion Teklogix 7535 Hand-Held Computer User Manual 63Chapter 4: Working With Windows CEWorking With Files, Folders And Programs4.2  Working With Files, Folders And ProgramsFigure 4.1 Working With Windows Icons• Use the arrow keys to highlight the icon you want to open or launch.• Press <ENTER>.If you have a touchscreen:• Double-tap on the appropriate icon – either a folder icon, a program icon or a file icon – to open or launch your selection.FolderFileProgram Icon
Chapter 4: Working With Windows CEThe Startup Desktop64 Psion Teklogix 7535 Hand-Held Computer User Manual4.3  The Startup DesktopWhen the 7535 boots up, the startup desktop (shell) is displayed. Any applications stored in the Startup folder start up immediately.Note: The startup folder is located in \Windows\StartUp and \Flash Disk\StartUp.Figure 4.2 The 7535 Startup DesktopTo access desktop icons:• Use the arrow keys to highlight the icon, and press <ENTER> to launch the highlighted icon.Note: If the arrow keys do not highlight the desktop icons, the desktop may not be selected. Press <BLUE> 0 (zero) to display the Start Menu, and select Desktop. Now the desktop will be “in focus” and the arrow keys will high-light the icons.If you have a touchscreen:• Tap on the icon to open a window or, in the case of an application icon, launch an application.
Psion Teklogix 7535 Hand-Held Computer User Manual 65Chapter 4: Working With Windows CEThe Desktop Icons4.3.1  The Desktop IconsThe icons displayed in the startup desktop operate in much the same way as those displayed on any standard PC desktop that is running Windows®.My ComputerChoosing this icon displays the contents of your 7535 computer. If you’re not sure how to work with the files, folders and programs displayed, refer to “Working With Files, Folders And Programs” on page 63.Recycle BinThis option temporarily contains items that were deleted, allowing you to either permanently delete or restore these items.Internet ExplorerChoosing this icon launches Internet Explorer – a standard Windows CE version. Keep in mind that your supervisor will need to set up access using the Internet Options and the Network and Dial-up Connections icons in the Control Panel. Remote Desktop ConnectionThis option allows your 7535 to communicate with a remote desktop PC. “Remote Desktop Connection” on page 83 provides a website with step-by-step instructions.
Chapter 4: Working With Windows CEThe Taskbar66 Psion Teklogix 7535 Hand-Held Computer User Manual4.3.2  The TaskbarFigure 4.3 The TaskbarThe 7535 is equipped with a taskbar at the bottom of the screen. It displays icons through which you can view the battery capacity and radio signal quality of your unit. If the hand-held is attached to a charger, cradle, docking station or PDM, an associated icon is displayed. In addition, the taskbar displays the application(s) currently running on your unit and the security level assigned to your 7535.The taskbar also displays active modifier keys – <SHIFT>, <ALT>, <CTRL>, <BLUE> and <ORANGE>. Keys that have been locked “on” are displayed in uppercase letters. For example, if you press the <CTRL> key twice to lock it “on”, it is displayed as CTRL KEY in the taskbar.4.3.2.1 Using The Taskbar• Press <BLUE> <0> to display the Start Menu.• Type <Y> to choose System Tray from the menu. • Use the arrow keys to highlight the icon in the taskbar about which you’d like more information.• Press <ENTER> to display the appropriate dialogue box.If you have a touchscreen:• Using the stylus, tap on the indicator you want to view – the battery icon for example – to display a dialogue box listing the current battery capacity information.
Psion Teklogix 7535 Hand-Held Computer User Manual 67Chapter 4: Working With Windows CECustomizing The Taskbar4.3.2.2 Customizing The TaskbarTo customize the taskbar so that it displays only those icons you require:• Press <BLUE> <0> (zero) to display the Start Menu.• Highlight the Settings option, highlight Taskbar... in the sub-menu, and press <ENTER>. The Taskbar and Start Menu dialogue box is displayed.Figure 4.4 Taskbar And Start Menu Settings• Under the General tab, highlight the options you want to activate, and press the <SPACE> key to select them. A check mark indicates active items.If you have a touchscreen:• Tap the stylus on the items you want to activate or deactivate. The check mark indicates active items.
Chapter 4: Working With Windows CEThe Start Menu68 Psion Teklogix 7535 Hand-Held Computer User Manual4.4  The Start MenuNote: Some of the Start Menu items may be disabled based on the 7535’s current security settings.The Start Menu lists the operations you can access and work with. It is available from the startup desktop or from within any application.To display the menu:• Press <BLUE> <0> (zero).Figure 4.5 Start Menu• Use the arrow keys to highlight a menu item, and press <ENTER>, or If the menu item has an underlined character:• Type the underlined alpha character – for example, to display the Power Info dialogue box, type the letter p.If you have a touchscreen:• Tap on the Windows® Start button in the taskbar. Tap on the item in the menu with which you want to work.4.4.1  The DesktopChoosing the Desktop option from the Start Menu displays the 7535 desktop.
Psion Teklogix 7535 Hand-Held Computer User Manual 69Chapter 4: Working With Windows CESecurity Settings4.4.2  Security SettingsChoosing the Security option from the Start Menu displays a dialogue box in which you can define the access level for the 7535 – Teklogix, Supervisor or User. Figure 4.6 Security LevelsSecurity LevelThese security levels define the options accessible to the operator in the Start Menu and the taskbar. When you change security levels, you’ll need to enter the appropriate password in the Password textbox. The security level is represented by an icon in the shape of a lock in the taskbar.Changing A PasswordNote: Keep in mind that this is the same password as that assigned through the Password control panel applet. Refer to “Control Panel Icons” on page 84.To assign a password:• Choose a security level, and enter the existing password in the Password field• Choose the Set Password button.A dialogue box labelled Password Properties is displayed.• Type the new password in the Password: text box• In the Confirm Password: text box, retype the new password.
Chapter 4: Working With Windows CEThe System Tray70 Psion Teklogix 7535 Hand-Held Computer User ManualConfiguring SecurityChoosing the Configure button displays the Configure Security dialogue box.Figure 4.7 Configuring SecurityThis dialogue box allows you to determine which security levels will have an associated icon displayed in the taskbar. By default, a security icon is not displayed for user-level security.4.4.3  The System TrayThe System Tray option allows access to the icons in the taskbar at the bottom of the screen. The taskbar displays indicators such as a battery capacity gauge and the security level. These indicators are attached to dialogue boxes that provide additional information. • Choose System Tray from the Start Menu.When System Tray is chosen, the taskbar icons become accessible. To display the dialogue box attached to an icon:• Use the arrow keys to highlight an icon – for example – the security icon.• Press <ENTER> to display the security level dialogue box.If you have a touchscreen:• Tap on the icon with which you want to work. The associated dialogue box is displayed.
Psion Teklogix 7535 Hand-Held Computer User Manual 71Chapter 4: Working With Windows CEThe Task Manager4.4.4  The Task ManagerThe Task Manager option allows you to switch to another task or to end an active task. To display the task manager window:• Press <BLUE><0><T>, or • Press <ALT> <ESC>.Figure 4.8 Task Manager4.4.5  Cycle TasksWhen Cycle Tasks is selected (and the Task Manager is not open), you can cycle through active applications. To choose this option:• Press <BLUE><0>, and type <C>, or• Press <ALT> <TAB>.4.4.6  Power InfoSelecting Power Info from the Start Menu displays the Power Properties dialogue box. This dialogue box indicates the remaining charge capacity of the battery.
Chapter 4: Working With Windows CEPrograms72 Psion Teklogix 7535 Hand-Held Computer User Manual4.4.7  ProgramsWith Programs highlighted, press the <RIGHT> arrow key to display a sub-menu of options.Figure 4.9 Program Sub-MenuThis sub-menu allows you to choose ActiveSync and Command Prompt, and you can access the Internet Explorer, installed applications (e.g., Open Tekterm), Remote Desktop Connection or Windows Explorer.ActiveSync®This option allows you to connect to another device using ActiveSync.Command PromptCommand Prompt is used to access the DOS command prompt. At the prompt, you can type DOS commands such as dir to display all the directories in the drive.Internet ExplorerThe 7535 is equipped with Microsoft® Internet Explorer consistent with all Windows CE devices on the market. You can access the Internet Options icon through the Start Menu under Settings>Control Panel or by double-tapping on the desktop icon labelled My Computer and then, double-tapping on the Control Panel icon.
Psion Teklogix 7535 Hand-Held Computer User Manual 73Chapter 4: Working With Windows CESettingsWindows ExplorerWindows Explorer installed on your 7535 is consistent with all Windows CE.NET 4.2 devices. You can access this option either from the Start Menu under Programs>Windows Explorer.Remote Desktop ConnectionRemote Desktop Connection is a 7535 application used to connect to a Windows Terminal Server so that you can run a “session” on the Server machine using the 7535 (Windows CE device). “Remote Desktop Connection” on page 83 provides a website with details about this option.4.4.8  SettingsWith Settings highlighted, pressing the <RIGHT> arrow key displays a sub-menu of options, including Control Panel, Network and Dial-up Connections and Taskbar and Start Menu settings.Figure 4.10 Settings Sub-MenuControl PanelThe Control Panel contains applets used to configure hardware, the operating system and the shell. If your 7535 is running with the Psion Teklogix Tekterm application or another application, additional configuration applets may appear in the Control Panel.
Chapter 4: Working With Windows CERun74 Psion Teklogix 7535 Hand-Held Computer User ManualNetwork And Dial-Up ConnectionsThe Network and Dial-up Connections window allows you to configure the 7535 radio or execute an existing configuration. Refer to “Configuring An IEEE 802.11 Radio Installed In The 7535” on page 18 for radio setup details.Taskbar And Start MenuThe Taskbar and Start Menu option displays a dialogue box in which you can customize the taskbar, choosing which options will be displayed. Refer to “Customizing The Taskbar” on page 67 for additional details about this option.4.4.9  RunChoosing the Run option from the Start Menu displays a dialogue box in which you can enter the name of the program, folder or document you want to open or launch.Figure 4.11 Run Dialogue Box
Psion Teklogix 7535 Hand-Held Computer User Manual 75Chapter 4: Working With Windows CEShutdown4.4.10  ShutdownWith Shutdown highlighted, pressing the <RIGHT> arrow key displays a sub-menu of options, including Suspend, Warm Reset and Cold Reset.Figure 4.12 Shutdown Sub-MenuNote: This menu varies slightly depending on the security level chosen. When the 7535 is set to User level, the Shutdown option is replaced by Suspend. A sub-menu is not available.At Teklogix security level, an additional option is available in the sub-menu – Bootloader. This option behaves like cold-reset, exceptthat the 7535 starts Bootloader rather than Windows CE.SuspendThe Suspend option suspends the 7535 immediately – this is equivalent to turning the hand-held off.Warm ResetThe Warm Reset option resets the 7535, leaving all saved files and (registry) settings intact. Any unsaved data is lost.Cold ResetThe Cold Reset option resets the 7535. Any files not stored in permanent memory are lost. However, the registry settings are saved.
Chapter 4: Working With Windows CEUsing A Dialogue Box76 Psion Teklogix 7535 Hand-Held Computer User Manual4.5  Using A Dialogue BoxA dialogue box (like the samples in Figure 4.13) appears when you need to make selections and enter further information. You can move between dialogue items by tapping on them, or by pressing the arrow keys and the <TAB> key. (<SHIFT> <TAB> moves the cursor backwards.)Figure 4.13 Dialogue BoxesNote: If your unit is equipped with a touchscreen, you can use the stylus to tap on an element in a dialogue box to select or deselect it, display dropdown menu items, save your selections, and so on.Dialogue boxes contain one or more of the following elements:Tab: A tab separates different elements of a dialogue box. Press the <TAB> key until a tab in the dialogue box is highlighted. To display adjoining tabs, press the <RIGHT> or <LEFT> arrow key. To display the information in the next tab from anywhere in the window, press <CTRL> <TAB>.Textbox: A textbox requires that you type information. Press the <TAB> key to highlight the textbox and then type the appropriate information.Dropdown: This type of menu is identified by up and down arrows next to the dropdown menu to indicate that additional options are available. Press the <TAB> key to highlight the menu, and use the arrow keys on your keyboard to cycle through the options. CheckboxDropdown MenuButtonTextboxRadioButtonTabs
Psion Teklogix 7535 Hand-Held Computer User Manual 77Chapter 4: Working With Windows CEUsing A Dialogue BoxCheckbox: This box allows you to select or deselect an option. To select or deselect a checkbox, press the <TAB> key to highlight the checkbox, and press the <SPACE> key to select (√) or deselect it.Radio buttons: These buttons allow you to choose from a number of options. For example, in the sample screen in Figure 4.13 on page 76 you can choose to ‘Obtain an IP address via DHCP’ or ‘Specify an IP address’. Press the <TAB> key to highlight a radio button option, and then select a radio button by pressing the arrow keys to highlight the appropriate option.Buttons: This type of button allows you to ‘Save’, ‘Delete’ and so on the options you’ve chosen in a dialogue box. Use the <TAB> key to highlight the button you want to use. Press the <ENTER> key to activate it.Saving Your Choices: Once you’ve made all your changes, press the <ENTER> key to save your changes and exit the window.Note: A dialogue box item that is displayed in grey text indicates that it is not currently available.
Psion Teklogix 7535 Hand-Held Computer User Manual 79CONFIGURATION 555.1  Remote Desktop Connection ........................835.2  Pocket PC Compatibility ..........................835.3  The Control Panel ..............................835.4  Control Panel Icons .............................845.5  Basic Setup .................................885.5.1  Display Properties ..........................885.5.1.1  Display Contrast .......................885.5.1.2  Display Backlight ......................895.5.1.3  Display Appearance .....................915.5.2  Keyboard Properties .........................925.5.2.1  Key Repeat..........................925.5.2.2  Keyboard Backlight .....................935.5.2.3  Keyboard One Shot Modes .................945.5.2.4  Keyboard Macro Keys ....................955.5.2.5  Unicode Mapping ......................975.5.3  Volume And Sound Properties ....................995.5.3.1  Volume Adjustments .....................995.5.4  Power Management Properties ................... 1005.5.4.1  Battery Capacity ...................... 1005.5.4.2  Power Saving Schemes .................. 1015.5.4.3  Suspend Threshold..................... 1025.5.4.4  Charger Details ...................... 1035.5.5  Stylus Properties .......................... 1035.5.5.1  Setting Double-Tap Sensitivity .............. 1045.5.5.2  Touchscreen Calibration .................. 1045.5.6  Certificate Assignment ....................... 1055.7  Scanner Properties Setup ......................... 1185.7.1  Scanner Options .......................... 1185.7.2  Bar Codes .............................. 1215.7.2.1  Code 39 Settings ...................... 1225.7.2.2  Code 128 Settings ..................... 124
Chapter 5: Configuration80 Psion Teklogix 7535 Hand-Held Computer User Manual5.7.2.3  EAN 13 Settings ......................1255.7.2.4  EAN 8 ...........................1265.7.2.5  UPC And EAN Settings ..................1275.7.2.6  UPC A Settings.......................1275.7.2.7  UPC E Settings.......................1275.7.2.8  Codabar...........................1285.7.2.9  Code 93...........................1285.7.2.10  Code 11 ..........................1285.7.2.11  Interleaved 2 of 5 .....................1295.7.2.12  MSI Plessey........................1295.7.2.13  Discrete 2 of 5 ......................1295.7.2.14  IATA 2 of 5 ........................1305.7.2.15  Postal: Australian .....................1305.7.2.16  Postal: Japanese......................1305.7.2.17  Postal: Korean.......................1305.7.2.18  Postal: PlaNET ......................1315.7.2.19  Postal: PostNET......................1315.7.2.20  Postal: Royal Mail ....................1315.7.2.21  2D DataMatrix ......................1315.7.2.22  2D Maxicode .......................1315.7.2.23  2D PDF-417........................1315.7.2.24  2D Micro PDF-417 ....................1325.7.2.25  2D QR Code .......................1325.7.2.26  2D RSS Code .......................1325.7.2.27  Aztec ...........................1325.7.3  Translations .............................1325.8  SNMP (Simple Network Management Protocol) Setup..........1345.8.1  Contact Tab .............................1355.8.2  Communities Tab ..........................1365.8.2.1  Adding A Community ...................1375.8.2.2  Modifying A Community Setting .............1385.8.2.3  Removing An Existing Community ............1385.8.3  Trap Destination Tab ........................1395.8.3.1  Enabling Authentication TRAPS..............1395.8.3.2  Adding A Destination ...................1395.8.3.3  Changing A Destination ..................1405.8.3.4  Removing A Trap Destination ...............140
Psion Teklogix 7535 Hand-Held Computer User Manual 81Chapter 5: Configuration5.8.4  Permitted Hosts Tab ........................ 1415.8.4.1  Adding A Host ....................... 1415.8.4.2  Changing A Host...................... 142
Psion Teklogix 7535 Hand-Held Computer User Manual 83Chapter 5: ConfigurationRemote Desktop Connection5.1  Remote Desktop ConnectionRemote Desktop Connection is a 7535 application used to connect to a Windows Terminal Server so that you can run a “session” on the Server machine, using the 7535 (Windows CE device). Refer to the following website for step-by-step information about setting up this connection:http://www.microsoft.com/WindowsXP/pro/using/howto/gomobile/remotedesktop/default.asp5.2  Pocket PC CompatibilityThe 7535 supports the AYGShell API set that allows PocketPC-compatible applications to run on the hand-held. Microsoft® Windows® CE.NET 4.2 is designed to include application programming interface (API) compatibility support for the Microsoft Windows Powered Pocket PC 2002 shell in 7535s running Windows® CE.NET 4.2. The website listed below describes the APIs exposed through AYGShell and the application compatibility between Windows Powered Pocket PC 2002-based applications and Windows CE.NET 4.2-based devices:http://msdn.microsoft.com/library/default.asp?url=/library/en-us/dncenet /html/WINCENET_CEPCC_App.asp5.3  The Control PanelThe Windows CE Control Panel provides a group of icons through which you can set a variety of system-wide properties, such as mouse sensitivity, network configuration and the desktop color scheme.Note: If you are uncertain how to move around a dialogue box and make selec-tions, review “Using A Dialogue Box” on page 76.When the 7535 boots up, the startup desktop (shell) is displayed, and any applications stored in the Startup folder start up immediately.To access the Windows CE Control Panel:• Press BLUE> <0> to display the Start Menu.• Highlight Settings in Start Menu, and press the <RIGHT > arrow key to highlight the Control Panel option.• Press the <ENTER> key to display the contents of the Control Panel window.
Chapter 5: ConfigurationControl Panel Icons84 Psion Teklogix 7535 Hand-Held Computer User ManualIf you have a touchscreen:• Use the stylus to tap on the Windows Start button in the taskbar to display the Start Menu. Tap on Settings>Control Panel.The Control Panel folder contains icons used in the setup of your 7535. Figure 5.1 Control Panel5.4  Control Panel IconsThe Windows CE Control Panel provides a group of icons that allow you to customize and adjust settings on your 7535.Date/TimeAllows you to set the current Month, Date, Time and Time Zone on your unit.DisplayChanges the appearance (window colour scheme) on the unit desktop.KeyboardToggles character repeat on and off and specifies delay and rate for repeated characters. It also allows you to adjust the keyboard backlight threshold and intensity.
Psion Teklogix 7535 Hand-Held Computer User Manual 85Chapter 5: ConfigurationControl Panel IconsVolume & SoundAllows you to adjust the volume of the beep that is emitted to indicate events like warnings, key clicks and, if your unit is equipped with a touch-screen, screen taps.Sounds (wave files) cannot be reproduced on 7535 units. The beeper volume and the conditions under which it sounds are tailored from within the application installed on your unit.Mouse PropertiesFor units equipped with touchscreens, this icon allows you to customize the sensitivity and speed of the stylus double-tap.OwnerProvides fields in which you can specify owner information. A ‘Notes’ tab allows additional information to be entered and displayed when the unit is powered up. ‘Network ID’ tab information is used to access network resources. (This information should be provided by your System Administrator.)PasswordAllows you to assign a password to restrict access to elements of the unit. Once assigned, password access cannot be circumvented so it is important that you write down your password and keep it in a safe place. Refer to “Security Settings” on page 69 for details.PowerDisplays battery pack power status. (Alternately, battery status can be accessed through the taskbar.) The ‘Power Scheme’ tab allows you to deter-mine a suspend states, and the ‘Charger’ tab determines whether or not a battery that requires it, can be recalibrated. (Refer to “Power Saving Schemes” on page 101 for details.)
Chapter 5: ConfigurationControl Panel Icons86 Psion Teklogix 7535 Hand-Held Computer User ManualRegional SettingsAllows you to specify the local language the display text will use along with the format of numbers, currency, time and date for your region. Remove ProgramsLists the programs that can be removed from your unit. To remove a pro-gram, select it and then click on the Remove button.StylusAdjusts how Windows CE recognizes your double-tap (as slow or rapid successive taps).Under the ‘Calibration’ tab, you can recalibrate your touchscreen by tapping on the ‘Recalibrate’ button and following the directions on the calibration screen.SystemDisplays system and memory properties. Under the Memory tab, you can allocate memory between storage memory and program memory.DialingSpecifies dialing settings, including area code, country code, dial type and the code to disable call waiting. You can store multiple patterns – for exam-ple, ‘Work’, ‘Home’, and so on using this dialogue box.CertificatesA public key is transmitted as part of a certificate. The certificate assigned through this icon is used to ensure that the submitted public key is, in fact, the public key that belongs to the submitter. The client checks that the cer-tificate has been digitally signed by a certification authority that the client explicitly trusts. “Certificate Assignment” on page 105 directs you to the appropriate setup information.
Psion Teklogix 7535 Hand-Held Computer User Manual 87Chapter 5: ConfigurationControl Panel IconsPC ConnectionEnables direct connections to a desktop computer. Selecting the ‘Change Con-nection’ button allows you to change the type of direct connect to your PC.Teklogix ScannersUsed to set up scanner parameters and choose the bar code symbologies that the 7535 scanner will successfully read.Network And Dial-up ConnectionsDisplays a network window from which the 7535 radio can be configured and an existing configuration can be executed. Refer to “Configuring An IEEE 802.11 Radio Installed In The 7535” on page 18 for details.Internet OptionsUsed to configure your Internet browser including options such as identify-ing the default and search page that the browser applies when connecting to the Internet, setting the cache size, specifying the Internet connection options, and defining the security level that is applied when browsing.SNMPSNMP (Simple Network Management Protocol) is the protocol used to monitor and manage devices attached to a TCP/IP network.Input PanelThe 7535 is equipped with the framework for a Soft Input Panel (SIP) should you need to design your own SIP.
Chapter 5: ConfigurationBasic Setup88 Psion Teklogix 7535 Hand-Held Computer User Manual5.5  Basic Setup5.5.1  Display Properties• In the Control Panel, choose the Display icon.Figure 5.2 Choosing The Display Icon5.5.1.1 Display ContrastThe Contrast tab allows you to adjust the 7535 display contrast to suit the environment in which you are using the hand-held.
Psion Teklogix 7535 Hand-Held Computer User Manual 89Chapter 5: ConfigurationDisplay Backlight• In the Display Properties dialogue box, open the Contrast tab.Figure 5.3 Display Contrast PropertiesSliding bar in the Contrast tab to the left decreases or darkens the display contrast. Sliding the bar to the right to increases or lightens the display contrast.5.5.1.2 Display BacklightThe backlight is activated for a configurable amount of time if the ambient light is below a specified threshold and if the 7535 is in use (key press, scanner trigger or data received from the host). The Display Properties dialogue box in the Control Panel allows you to specify the intensity of the backlight along with how the backlight behaves in low-light conditions and when the unit is not in use.Note: Keep in mind that this option may be restricted to supervisory use only.
Chapter 5: ConfigurationDisplay Backlight90 Psion Teklogix 7535 Hand-Held Computer User Manual• In the Display Properties dialogue box, open the Backlight tab.Figure 5.4 Display Backlight PropertiesNote: Backlight changes take affect immediately. You do not need to reset the 7535. ON ThresholdThe 7535 is equipped with an ambient light sensor. This sliding bar allows you to determine how dark the ambient light needs to be before the backlight turns on.IntensityThis parameter is used to adjust the light intensity of the 7535 backlight. Sliding the bar to the left lowers the light intensity, and sliding it to the right raises the intensity.Bright ForThe value chosen from this dropdown menu determines the duration of time that the backlight stays on at the configured intensity when a unit is not in use. Dim ForThe value chosen from this dropdown menu determines the duration of time that the backlight stays on at half the configured intensity (dimmed backlight) when a unit is not in use.
Psion Teklogix 7535 Hand-Held Computer User Manual 91Chapter 5: ConfigurationDisplay AppearanceExternal Power CheckboxWhen you select (√) the checkbox next to ‘When using external power keep the backlight always ON.’, the backlight remains ON at the configured intensity when the 7535 is operating with external power (not battery power). If the 7535 is drawing power from its battery, this option is ignored and the other parameters defined in Display Properties dialogue box take affect.5.5.1.3 Display Appearance• In the Display Properties dialogue box, open the Appearance tab.Figure 5.5 Display Appearance PropertiesThis dialogue box allows you to customize the display colour scheme.
Chapter 5: ConfigurationKeyboard Properties92 Psion Teklogix 7535 Hand-Held Computer User Manual5.5.2  Keyboard PropertiesThis icon displays the Keyboard Properties dialogue box in which you can adjust the repeat rate of the keys, the intensity of the keyboard backlight and the behaviour of the <BLUE> and <ORANGE> modifier keys. This dialogue box also allows you to define macro keys and Unicode characters.• In the Control Panel, choose the Keyboard icon.Figure 5.6 Choosing The Keyboard Icon5.5.2.1 Key Repeat• In the Keyboard Properties dialogue box, open the Repeat tab.Figure 5.7 Key Repeat Properties
Psion Teklogix 7535 Hand-Held Computer User Manual 93Chapter 5: ConfigurationKeyboard BacklightRepeat DelayThe value assigned for this parameter determines the delay in milliseconds between repeat characters. Sliding the Repeat Delay bar to the left increases the delay between key repeats while sliding the bar to the right shortens the repeat delay time.Repeat RateThe value assigned for the Repeat Rate parameter determines how quickly the key you press repeats and is measured in characters per second (cps). Sliding the bar to the left slows the repeat rate, and sliding the bar to the right increases the repeat rate.Note: Use the field at the bottom of this dialogue box to test the repeat delay and rate settings you’ve chosen.5.5.2.2 Keyboard Backlight• In the Keyboard Properties dialogue box, open the Backlight tab.Figure 5.8 Keyboard Backlight PropertiesON ThresholdThe ON Threshold sliding bar allows you to determine how dark the ambient light needs to be before the keyboard backlight turns on.IntensityThis parameter is used to adjust the light intensity of the 7535 keyboard backlight. Sliding the bar to the left darkens the keyboard backlight intensity, and sliding it to the right lightens the intensity.
Chapter 5: ConfigurationKeyboard One Shot Modes94 Psion Teklogix 7535 Hand-Held Computer User ManualON TimeThe value chosen from this dropdown menu determines the duration of time that the keyboard backlight stays on when a unit is not in use.5.5.2.3 Keyboard One Shot Modes• In the Keyboard Properties dialogue box, open the One Shots tab.Figure 5.9 Keyboard One Shot PropertiesWhen these options are enabled (√), the <ORANGE> and <BLUE> keys only remain active until the next key is pressed. If the ‘One Shots’ options are disabled (the checkbox is left blank), the <ORANGE> and <BLUE> keys are locked ‘on’ when pressed only once; they remain ‘on’ until they are pressed a second time to unlock them.Note: Keep in mind that checking the taskbar lets you know whether or not these keys are locked on. When the <ORANGE> and <BLUE> keys are locked ‘on’, the taskbar at the bottom of the screen displays them in uppercase characters – BLUE KEY and ORANGE KEY. If these keys are dis-played in lowercase characters in the taskbar, you’ll know that the Blue Key and the Orange Key are not locked. They will become inactive following a key press.
Psion Teklogix 7535 Hand-Held Computer User Manual 95Chapter 5: ConfigurationKeyboard Macro Keys5.5.2.4 Keyboard Macro Keys• In the Keyboard Properties dialogue box, open the Macros tab.Figure 5.10 Macro Dialogue BoxA macro has 20 programmable characters (or “positions”). The macro keys can be programmed to replace frequently used keystrokes, along with the function of executable keys including <ENTER>, <BKSP> and <DEL> (<BLUE>-<BKSP>), function keys and arrow keys. Recording And Saving A MacroYou can program up to 12 macro keys on a 58-key keyboard and 6 macro keys on a 36-key keyboard.• In the Macro: menu, highlight a macro key number – for example, macro 1 to assign a macro to macro key <M1>. Press the <TAB> key twice to highlight the Record Macro button, and press <ENTER>.
Chapter 5: ConfigurationKeyboard Macro Keys96 Psion Teklogix 7535 Hand-Held Computer User ManualA message screen is displayed instructing you to ‘Please Enter Key Strokes’. Figure 5.11 Recording A Macro• Type the macro sequence you want to assign to the Macro key. You can type text and numbers, and you can program the function of special keys into a macro.• When you’ve finished recording your macro sequence, press the key sequence – <CTRL> <ALT> <ENTER>.A new screen displays the macro sequence you created. The Save Macro button is highlighted. • Press <ENTER> to save your macro.Note: If you want to discard the macro you’ve just created, press the <TAB> key to highlight the Discard Macro button and press <ENTER>.Executing A MacroTo execute a macro:• Press the macro key to which you’ve assigned the macro. For example, if you created a macro for macro key ‘1’, press <M1> to execute the macro.
Psion Teklogix 7535 Hand-Held Computer User Manual 97Chapter 5: ConfigurationUnicode MappingDeleting A MacroTo delete a macro:• In the Macros tab, use the arrow keys to highlight the macro number you want to delete.• Press <TAB> to highlight the Delete Macro button, and press <ENTER>.5.5.2.5 Unicode Mapping• In the Keyboard Properties dialogue box, open the Unicode Mapping tab.Figure 5.12 Unicode MappingThe Unicode Mapping tab is used to map combinations of virtual key values and <CTRL> and <SHIFT> states to Unicode™ values. This tab shows the configured Unicode character along with the Unicode value. For example, the sample screen above shows “a (U+0061)” indicating that the character “a” is represented by the Unicode value “0061”, and so on. Keep in mind that Unicode configurations are represented as hexidecimal rather than decimal values.All user-defined Unicode mappings are listed in the Unicode Mapping tab in order of virtual key value, and then by order of the shift state. If a Unicode mapping is not listed, the Unicode mapping is mapped to the default Unicode value.
Chapter 5: ConfigurationUnicode Mapping98 Psion Teklogix 7535 Hand-Held Computer User ManualAdding And Changing Unicode ValuesImportant: Changes to Unicode mappings are not saved until you exit the Keyboard Properties dialogue box.• Press <TAB> to highlight the Add/Change button, and press <ENTER>.Figure 5.13 Adding And Change Unicode Values• Highlight the a value in the Unicode mapping list – in the sample screen above, a value will be assigned to virtual key 0 (VK 0).• Press <TAB> to position the cursor in the ‘Unicode Mapping’ field and type a Unicode value for the highlighted key.Note: To add a shifted state – <SHIFT> and/or <CTRL>, press <TAB> to posi-tion the cursor in the checkbox next to ‘SHIFT Pressed’ and/or ‘CTRL Pressed’. Press <SPACE> to select (√) the shift state you want to assign.Removing Unicode Values• In the ‘Unicode Mapping’ tab, highlight the item you want to delete, and press <TAB> to highlight the Remove button.• Press <ENTER> to delete the value.
Psion Teklogix 7535 Hand-Held Computer User Manual 99Chapter 5: ConfigurationVolume And Sound Properties5.5.3  Volume And Sound PropertiesNote: Sounds (wave files) cannot be reproduced on 7535 units. The conditions under which 7535s emit sounds are tailored from within the application installed on your unit.• In the Control Panel, choose the Volume & Sounds icon.Figure 5.14 Choosing The Volume Icon5.5.3.1 Volume AdjustmentsFigure 5.15 Volume Settings• Slide the volume button to the left to lower the beeper volume or to the right to increase the beeper volume.• Under the heading ‘Enable sounds for:’, enable (√) the conditions under which you want the 7535 to emit a beep.
Chapter 5: ConfigurationPower Management Properties100 Psion Teklogix 7535 Hand-Held Computer User Manual5.5.4  Power Management PropertiesThis icon displays a Power Properties dialogue box that indicates the unit’s battery capacity and allows you to manage battery use.• In the Control Panel, choose the Power icon.Figure 5.16 Choosing The Power Icon5.5.4.1 Battery Capacity• In the Power Properties dialogue box, open the Battery tab.Figure 5.17 Power Battery PropertiesThe Battery tab details information about the battery installed in your 7535.
Psion Teklogix 7535 Hand-Held Computer User Manual 101Chapter 5: ConfigurationPower Saving Schemes5.5.4.2 Power Saving Schemes• In the Power Properties dialogue box, open the Schemes tab.Figure 5.18 Power Scheme PropertiesPower SchemeThis dropdown menu allows you to specify whether the unit is using AC Power or Battery Power.Switch State To SuspendImportant: Psion Teklogix recommends setting the Suspend value to 10 min-utes. Setting ‘Switch State To Suspend’ to ‘Never’ will adversely affect the battery run time. To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Display Backlight” on page 89).When the 7535 is idle – not receiving any user input (a key touch, a scan, and so on) or system activity (serial data, an activity initiated by an application, and so on), the hand-held uses the value assigned in the Switch State To Suspend field to determine when the unit will go to sleep (appear to be off). When the time in the Suspend field elapses without any activity, the unit enters Suspend state. In Suspend state, the 7535 CPU enters a sleep state, and the radio is shut off. The state of the device (RAM contents) is preserved. Pressing <ENTER> wakes the system from suspend state. When the 7535 is in suspend state, the network connection will not be broken immediately. If the connection is dropped, you must re-establish the network connection.
Chapter 5: ConfigurationSuspend Threshold102 Psion Teklogix 7535 Hand-Held Computer User Manual5.5.4.3 Suspend Threshold• In the Power Properties dialogue box, open the Suspend Threshold tab.Figure 5.19 Suspend Threshold PropertiesSuspend ThresholdThe sliding bar in this tab is used to set the battery capacity (as a percentage value) at which the hand-held will be forced into a suspend state. For example, if you slide the bar in the Suspend Threshold tab to the right to the 10% level, when the battery capacity falls to 10%, the 7535 will enter suspend state. You will not be able to resume until the battery is charged, or you operate the 7535 using AC power. The allowable threshold ranges from 0 to 50%. The default value is 0%.Note: The7535 hand-held does not enter suspend state when it is using AC power.Main Battery Status This field indicates the status of the main battery.Estimated Operating TimeThis field estimates the length of time the 7535 can remain ‘on’ (operating) before reaching the configured Suspend Threshold. Estimated Battery Backup TimeThis field displays the amount of time the state of the 7535 will be maintained in suspend at the currently configured Suspend Threshold.
Psion Teklogix 7535 Hand-Held Computer User Manual 103Chapter 5: ConfigurationCharger Details5.5.4.4 Charger Details• In the Power Properties dialogue box, open the Charger tab.When the 7535 is in a Combo Dock, enabling (√) Allow Battery Calibration in this tab allows a battery requiring recalibration to be fully discharged and recharged.Recalibration occasionally extends the battery charge time. If you prefer that the battery always be charged in the shortest time possible, do not check this box.5.5.5  Stylus PropertiesNote: Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor.• In the Control Panel, choose the Stylus icon.Figure 5.20 Stylus Icon
Chapter 5: ConfigurationSetting Double-Tap Sensitivity104 Psion Teklogix 7535 Hand-Held Computer User Manual5.5.5.1 Setting Double-Tap Sensitivity• In the Double-Tap tab, follow the directions to tailor the sensitivity of the stylus when you tap on the touchscreen.Figure 5.21 Setting Stylus Sensitivity5.5.5.2 Touchscreen CalibrationTouchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below.• Choose the Calibration tab and then tap on the Recalibrate button.Figure 5.22 Calibrating The Touchscreen• Follow the directions in the Calibration tab to recalibrate the screen.
Psion Teklogix 7535 Hand-Held Computer User Manual 105Chapter 5: ConfigurationCertificate Assignment5.5.6  Certificate Assignment• In the Control Panel, choose the Certificate icon.The dialogue box is used in conjunction with 802.1x authentication to enhance 7535 security. Figure 5.23 Certificates Dialogue BoxFor a detailed description about Certificate setup for both the server and client-side devices (7535s), refer to the following website:www.microsoft.com/windows2000/techinfo/planning/walkthroughs/default.asp - "Security Services"Note: When importing certificates, the 7535 only recognizes .cer files.
5.7  Scanner Properties SetupThe Teklogix Scanners icon in the Control Panel provides dialogue boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize.5.7.1  Scanner OptionsFigure 5.45 Bar Code OptionsTo display the sub-menus available in the Options tab:• Highlight the option you want to work with, and press the right <ARROW> key.To change a parameter:• Highlight the parameter and press the <RIGHT> arrow key, or press the <SPACE> key.If a field requires text entry, a text field is displayed in which you can type the appropriate value.Display ParametersScan ResultWhen this parameter is enabled (set to ‘ON’), the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen.
Psion Teklogix 7535 Hand-Held Computer User Manual 119Chapter 5: ConfigurationScanner OptionsScan IndicatorWhen this parameter is enabled (set to ‘ON’), the laser warning logo appears on the display whenever the scanner is activated.Scan Result Time (sec)The value assigned to the “Scan Result Time (sec)” parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of “0” (zero) disables the parameter.Note: To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger.Scan BeepThis parameter determines whether or not the 7535 emits an audible scanner ‘beep’ when a scan is performed. Set this parameter to either ‘ON’ to enable the beeper or ‘OFF’ to disable it.Scan Log FileIf this parameter is enabled, the input barcode and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the ‘Scan Log File’ is enabled, there is a slight performance effect when performing multiple scans since the log file is written to persistent storage.Double Click ParametersClick Time (msec)This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is considered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature.A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click Data” value rather than initiating a scan.
Chapter 5: ConfigurationScanner Options120 Psion Teklogix 7535 Hand-Held Computer User ManualClick DataFor both integrated and external scanners, this parameter determines which character is sent to the application installed in your 7535 following a double-click. A dialogue box appears, asking that you press the key you want to insert. The ASCII/Unicode key value of the keypress is displayed. Pressing the <ESC> key in this dialogue box resets the data to zero.OptionsDot Time (msec)The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep. The allowable values are: 0, 0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0 seconds. A value of 0 (zero) disables the target dot.Short CodeWhen enabled (set to ‘ON’), this parameter allows scanning of short I 2 of 5 bar codes (2 characters). When disabled, these short bar codes are rejected.Enabling “Short Code” may reduce the robustness of the decoding since the 7535 must decode more potential bar codes; it is therefore not recommended for general-purpose bar codes with 4 or more characters.VerifyThe value entered for this parameter determines the number of correct additional decodes required after the initial decode before a bar code is accepted. Higher values significantly increase the time it takes to decode a bar code but also improve the reliability of the decoded bar code.SecurityThis parameter controls the tolerance for decoding edge-to-edge bar codes (Code 93, Code 128, UPC/EAN). Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code. The default value of 30 is generally a good compromise setting.
Psion Teklogix 7535 Hand-Held Computer User Manual 121Chapter 5: ConfigurationBar Codes5.7.2  Bar CodesFigure 5.46 Bar Code SelectionAll the available bar code symbologies can be selected from this menu.Important: To improve the decode speed and performance, enable (set to ‘ON’) only those codes that are required by the application.Keep in mind that some bar code types are only available when an internal imaging scanner is installed. The bar code settings do not affect the operation of internal or external decoded scanners. These scanners must be configured by scanning special configuration bar codes. These configuration bar codes affect the communication speed or data format between the scanner and the 7535 and must not be changed. The scanner manufacturer provides programming manuals for configuration purposes.• For Symbol, refer to “Programming Guide P300”.• For PSC, refer to “Powerscan Programing guide (PSC)”.
Chapter 5: ConfigurationCode 39 Settings122 Psion Teklogix 7535 Hand-Held Computer User ManualFigure 5.47 Code 39 Bar Code SettingsA ‘plus’ sign (+) to the left of the each bar code listed in this Barcodes tab indicate that that a sub-menu of parameters is attached. To work with a sub-menu:• Highlight the bar code you want to work with, and press the <RIGHT> arrow key to display the sub-menu.• Use the <UP> and <DOWN> arrow keys to highlight a parameter. • To change a parameter value, press <SPACE> or the <RIGHT> arrow key. If a field requires text entry, a text box is displayed in which you can enter the appropriate value.5.7.2.1 Code 39 SettingsFull AsciiIf this parameter is enabled (set to ‘ON’), the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.Include CheckIf this parameter is enabled (set to ‘ON’), the check digit is included with the decoded bar code data.
Psion Teklogix 7535 Hand-Held Computer User Manual 123Chapter 5: ConfigurationCode 39 SettingsAIAG StripIf this parameter is enabled (set to ‘ON’), the AIAG data identifier is removed from each decoded Code 39 label. The data identifier occurs in the first position next to the Code 39 start character. It can be a single alphabetic character or a series of numeric digits followed by an alphabetic character. This identifier defines the general category or specific use of the data contained in the rest of the bar code.Note: If your unit is operating with the Psion Teklogix TESS application, this parameter should not be used in conjunction with the TESS AIAG feature. This is because the 7535 hand-held performs the strip function before it processes the data through the AIAG feature; if the prefix is stripped, the data is not identified as AIAG.Error AcceptIf the “Err Accept” and “AIAG Strip” parameters are enabled (set to ‘ON’), all label data without an AIAG identifier character is accepted. If the “Err Accept” parameter is disabled and the “AIAG Strip” parameter is enabled (set to ‘ON’), the label data is not accepted.Mod ChecksMod 43 CheckIf this parameter is enabled (set to ‘ON’), the Mod 43 check digit is calculated.Mod 10 CheckIf this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated.NoneIf you choose ‘None’, a check is not executed.Field Size/CharsField SizeThe field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.
Chapter 5: ConfigurationCode 128 Settings124 Psion Teklogix 7535 Hand-Held Computer User ManualPrefix CharThis character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed.Pressing the <ESC> key in this dialogue box resets the data to zero.Suffix CharNote: The appended character is treated as any other keyboard character. For example, if <BKSP> is pressed, the usual action for that key is performed. If your unit is operating with the Psion Teklogix ANSI emulation application, the 7535 transmits the escape sequence associated with the function immediately after the bar code data.This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialogue box attached to this parameter. The ASCII/Unicode key value of the keypress is displayed.Pressing the <ESC> key in this dialogue box resets the data to zero.Strip LeadingThis parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.Note: For Code 39 bar codes, the “AIAG Strip” is performed before the “Strip Leading”.Strip TrailingThe value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.5.7.2.2 Code 128 SettingsInclude SymSetting “Include Sym” to ‘ON’ causes the group separator(s) and start code contained in this type of bar code to be displayed on the screen.Note: This option is available only when ‘EAN/UCC 128’ is selected.

Navigation menu