Proxim Wireless MESHMAXMP11R 802.11 a/b/g Access Point User Manual MeshMAX5054Series QIG indd

Proxim Wireless Corporation 802.11 a/b/g Access Point MeshMAX5054Series QIG indd

Users Manual 1

Part Number 74432 (Print version)Part Number 74434 (CD version)Quick Install Guide MeshMAX 5054 Series
Page 2  Copyright © 2008 Proxim Wireless NOTICES© 2008 Proxim Wireless, San Jose, CA. All rights reserved. Covered by one or more of the following U.S. patents: 5,231,634; 5,875,179; 6,006,090; 5,809,060; 6,075,812; 5,077,753. This User Guide and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of Proxim Wireless Corporation.All rights reserved  Page 31www.proxim.com 1561 Buckeye Drive, MilpitasCA-95035Phone: 408-731-2700
Page 30  Copyright © 2008 Proxim Wireless TECHNICAL SERVICES AND SUPPORTIf you are having trouble utilizing your Proxim product, please review the MeshMAX 5054 User Guide amd the additional documentation provided with your product.If you require additional support, please refere to the “Technical Services and Support” chapter in the MeshMAX 5054 User Guide for details about the information you will need to gather before using the support Options listed below.Support OptionsProxim eService Web Site SupportThe Proxim eService Web Site is available 7x24x365 at: http://support.proxim.com/://support.proxim.com.Telephone SupportContact technical support via telephone as follows:US and Canada ▪: 408-383-7700, 866-674-6626 (Toll Free)Hours of Operations: 8AM - 6.00PMAPAC Countries: ▪ +90 40-23115490Hours of Operations: 9AM - 6.00PMInternational: ▪ 408-383-7700Hours of Operations: 8AM - 6.00PMServPak SupportProxim understands that service and support requirements vary from customer to customer. In recognition of these varying requirements we have developed a support program called ServPak. ServPak is a program of Enchanced Service Options that can be purchased individually or in combinations to meet your needs.Advanced Replacement ▪Extended Warranty ▪7x24x365 Technical Supports ▪Priority Queiuing ▪To learn more, please call Proxim Support at 408-383-7700 or send an email to servpak@proxim.com. To purchase ServPak support services, please contact your authorized Proxim distributor.       All rights reserved  Page 3CONTENTSIntroduction ................................................................... 4Package Contents ...........................................................6Hardware and Software Installation ...............................8Step 1: Choose a Location ......................................................................9Step 2: Unpack the Shipping Box .......................................................... 10Step 3: Assemble the Cable .................................................................. 11Step 4: Assemble Mounting Hardware .................................................... 12Step 5: Mount the Unit ........................................................................ 13Step 6: Plug in the Cables .................................................................... 14Step 7: Power on the Unit .................................................................... 15Step 8: View LEDs............................................................................... 16Step 9: Tighten the Cables ................................................................... 17Step 10: Weatherproof the Connectors .................................................. 18Step 11: Align the Antenna .................................................................. 19Step 12: Install Documentation and Software ......................................... 20Unit Initialization .........................................................21Mesh Unit Initialization ........................................................................ 21Subscriber Unit Initialization ................................................................. 28Technical services and support .....................................30Support Options .................................................................................. 30
Page 4  Copyright © 2008 Proxim Wireless INTRODUCTIONThe MeshMAX 5054 Series is a ruggedized tri-mode Mesh AP with additional 5 GHz subscriber station functionality. It is optimized for outdoor deployments. It is equipped with the following embedded modules:Mesh Module: ▪ One embedded 5 GHz (802.11a) module and one embedded 2.4 GHz (802.11b/g) module, enabling simultaneous support of 802.11a, 802.11b, and 802.11g clients. Both radios also support Mesh operation. Subscriber Module:  ▪One embedded module operating in the unlicensed 5 GHz band to enable high-speed backhaul The MeshMAX 5054 Series can operate either using PoE with the combination DC power supply/injector provided or directly from a 100 - 240 VAC power source (AC cable ordered separately).Each unit is equipped with:Power/Ethernet port:  ▪used for Ethernet connection and Power over Ethernet (PoE) using the supplied power injector.Serial connection: ▪ used for entering commands in the Command Line Interface (CLI).LED indicator(s):  ▪dual LEDs used to indicate the power and operational states of the unit.AC power input: ▪ enables direct power from external AC power source.External antenna connectors (three):  ▪one for 2.4 GHz client access, one for 5 GHz Mesh operation, and one 5 GHz Subscriber operation.Grounding screws (two) ▪Note:This product does not contain internal antennas. At least one external antenna must be used to make the product operational. For information on antennas authorized for use with this product, refer to the Safety and Regulatory Compliance Guide on the installation CD.All rights reserved  Page 29Enter the Read/Write Password (the default value is public) and click OK to confi rm your changes. The respective module reboots to make the effective.Accessing the Web BrowserTo access the module with a Web Browser:Start a Web browser (such as Internet Explorer) and enter the IP address of the module in the Address box (for example, http://10.0.0.1).A login window is displayed. Do not fi ll in the User name; enter only the default password public. Upon successful login, the System Status window is displayed.Accessing the Command Line InterfaceThe CLI is accessible through the Serial RS-232 cable connected through the network, or with a cross-over Ethernet cable between the computer and the module’s serial port.Ethernet PortTo use the CLI through the Ethernet port, you must have a telnet program, and the module’s IP address.To access the unit through Ethernet on a Windows PC:Open a DOS command window: from the Windows Start menu, Select Run; enter cmd.In the DOS window displayed, enter telnet and IP address (for example, telnet 10.0.0.1) and type <enter>. You will be prompted for your password. Enter the password (the default is public).Y-CableThe Y-cable has two DB9 connectors which connect to the RJ11. The long one connects to the Mesh console and the short one to the Subscriber console.
Page 28  Copyright © 2008 Proxim Wireless Subscriber InitializationConnecting to the module requires either:A direct physical connection with an Ethernet cable or with a serial RS-32  ▪cableA network connection ▪Connecting with the Ethernet cable allows you to access the unit through a terminal emulation program, such as HyperTerminal. (See “HyperTerminal Connection Properties” in the MeshMAX 5054 User Guide.Setting the IP AddressWith ScanTool (a software utility that is included on the product installation CD), you can fi nd out the current IP address of the unit and, if necessary, change it so that is appropriate for your network.ScanTool lets you fi nd the IP address of a module by referencing the MAC address in a Scan List, or to assign an IP address if the correct one has not been assigned. The tool automatically detects the units installed on your network segment, regardless of IP address, and lets you confi gure each unit’s IP settings. In addition, you can use ScanTool to download new software to a unit that does not have a valid software image installed.To discover and set/change the IP address of the unit:Run ScanTool on a computer connected to the same LAN subnet as the unit, or a computer directly connected to the module with a cross-over Ethernet cable. Double-click the ScanTool icon on the Windows desktop to launch the program. If the icon is not on your desktop, click Start > All Programs > MeshMAX 5054 series > ScanTool.ScanTool scans the subnet and displays the module it fi nds in the main window. If necessary, click Rescan to re-scan the subnet and update the display. You can assign a new IP address to one module, even if more than one module has the same (default) IP address 10.0.0.1, but the new IP address must be unique to allow the use of the management interfaces.Select the module for which you want to set the IP address and click Change. The Change dialog window is displayed.To set the IP address manually, ensure that Static is selected as the IP Address Type and fi ll in the IP Address and Subnet Mask suitable for the LAN subnet to which the uni is connected.To set the IP address dynamically, ensure that Dynamic is selected as the IP Address Type. The module will request its IP address from a DHCP server on your network.All rights reserved  Page 5   Figure 1: MeshMAX 5054 Unit
Page 6  Copyright © 2008 Proxim Wireless PACKAGE CONTENTSEach shipment includes the items in the following table. Verify that you have received all parts of the shipment.Note:Unless listed here, cables are not included with the unit.MeshMAX 5054 UnitY-cable connectorInstallation CD (1 ea.)Power Injector and Cord (1 ea.)Cable Termination Kit Kit includes:  A. RJ45 connectors (2)  B. Sealing caps (2)  C. Lock nut  D. Sealing nut  E. Grounding screws (2) A  B  C  D  EAll rights reserved  Page 27From the 3.  File Type drop-down menu, select Image.Use the 4.  Browse button to locate or manually type in the name of the fi le (including the fi le extension) you downloaded from the Proxim Knowledgebase. If typing the fi le name, you must include the full path and the fi le extension in the fi le name text box.To initiate the HTTP Update operation, click the 5.  Update AP button. A warning message advises you that a reboot of the device will be required for changes to take effect. Click 6.  OK to continue with the operation or Cancel to abort the operation.If the operation is unsuccessful, you will receive an error message. See 7. the MeshMAX 5054 User Guide for more information. If the operation is successful, you will receive a confi rmation message. Reboot the Mesh radio as follows:8. Click a.  Commands > Reboot.Enter b.  0 in the Time to Reboot fi eld.Click c.  OK.Note:For instructions on downloading the software via a TFTP Server or the CLI Interface, see the MeshMAX 5054 User Guide.
Page 26  Copyright © 2008 Proxim Wireless Software UpdatesProxim periodically releases updated software for the MeshMAX 5054 on its support Web site, http://support.proxim.com. Proxim recommends that you check the Web site for the latest updates after you have installed and initialized the unit.Download the SoftwareIn your web browser, go to 1.  http://support.proxim.com. If prompted, create an account to gain access.2. Note:The Knowledgebase is available to all Web site visitors. First-time users will be asked to create an account to gain access.Click3.   Search Knowledgebase.In the 4.  Search Knowledgebase fi eld, enter 2763.Click 5.  Search.Click on the link in the 6.  Summary column to access the download page. Click on the appropriate link to download the software. 7. Install the SoftwareEnter the Access Point’s IP address in the browser’s Address fi eld and press 1. Enter or Go. Click 2.  Commands > Update AP > via HTTP. The Update AP via HTTP screen will be displayed.All rights reserved  Page 7Mounting Kit Kit includes the following:  A. Mounting clamp for wall/pole  B. Extension arm  C. Mounting plate to enclosure  D. Mounting clamp for pole mounting  A  B  C  DMounting Hardware The following mounting hardware is included with mounting kit:Qty. Description6 ea Plain washer #5/162 ea. Hex cap screw NC 5/16-18 x 352 ea. Nut NC 5/16-184 ea. Helical spring lock washer # 1/44 ea. Helical spring lock washer #5/162 ea Hex cap screw NC 5/16-18 x 804 ea. 68764, Screw, Machine, Pan, Phillips, 1/4”-20, 5/8”LRubber Tape Strip
Page 8  Copyright © 2008 Proxim Wireless HARDWARE AND SOFTWARE INSTALLATIONNotes:Be sure to read the Release Notes fi le on the product CD as it contains  ▪software version and driver information that may not have been available when this document was produced.Equipment is to be used with, and powered by, the power injector provided  ▪or by a power injector that meets these requirements: UL-Listed/ITE (NWGQ) –Limited Power Source Output per UL/IEC 60950 –CE-marked –Approved for Power-over-Ethernet –Rated output, 48 Vdc/0.42 A –Pinout follows 802.3af standard for mid-span devices –IMPORTANT!Before installing this product, see Safety and Regulatory Compliance Information on the product CD for important information.IMPORTANT!All units must be installed by a suitably trained professional installation technician or by a qualifi ed installation service. WARNING!To ensure proper grounding, use the hole at the bottom point on the back of each unit and the provided grounding screws to attach a ground wire of at least 10 AWG stranded to each unit.  Use proper wire grounding tech-niques in accordance with local electric codes.  All rights reserved  Page 25Click Setup Wizard to begin. The Setup Wizard supports the following 1. navigation options:Save & Next Button ▪: Each Setup Wizard screen has a Save & Next button. Click this button to submit any changes you made to the unit’s parameters and continue to the next page. The instructions below describe how to navigate the Setup Wizard using the Save & Next buttons.Navigation Panel ▪: The Setup Wizard provides a navigation panel on the left-hand side of the screen. Click the link that corresponds to the parameters you want to confi gure to be taken to that particular confi guration screen. Note that clicking a link in the navigation panel will not submit any changes you made to the unit’s confi guration on the current page.Exit ▪: To exit from the Setup Wizard at any time, click Step 1:  Introduction on the navigation panel, and then click the Exit button. CAUTION:If you exit from the Setup Wizard, any changes you submitted (by clicking the Save & Next button) up to that point will be saved to the unit but will not take effect until it is rebooted.Follow the prompts provided by the Setup Wizard to perform an initial 2. confi guration of the Mesh radio. See the MeshMAX 5054 User Guide for more detailed Setup Wizard instructions and for advanced confi guration instructions.
Page 24  Copyright © 2008 Proxim Wireless Open a Web browser on a network computer. 1. If necessary, disable the browser’s Internet proxy settings. 2. Enter the Access Point’s IP address in the browser’s 3.  Address fi eld and press Enter or Go. This is either the dynamic IP address assigned by a network DHCP server or the static IP address you manually confi gured. See the Using ScanTool section above for information on how to determine the unit’s IP address and manually confi gure a new IP address, if necessary.The login screen appears.4. Enter the HTTP password in the 5.  Password fi eld. Leave the User Name fi eld blank. For new units, the default HTTP password is public.If you are logging on for the fi rst time the Setup Wizard will launch automatically.NoteSetup Wizard will not relaunch on subsequent logins. To force the Setup Wizard to launch upon login, click Management > Services and choose Enable from the Setup Wizard drop down menu.To confi gure the Mesh radio using the Setup Wizard, see 6.  Using the Setup Wizard, below.  To confi gure the radio without using the Setup Wizard, click Exit. Upon clicking Exit, the System Status screen will appear. See the “Advanced Confi guration” chapter in the MeshMAX 5054 User Guide for confi guration instructions. Using the Setup WizardThe Setup Wizard provides step-by-step instructions for how to confi gure the Access Point’s basic operating parameters, such as Network Name, IP parameters, system parameters, and management passwords.All rights reserved  Page 9Step 1: Choose a LocationTo make optimal use of the unit, you must fi nd a suitable location for the hardware. The range of the radio unit largely depends upon the position of the antenna. Proxim recommends you do a site survey, observing the following requirements, before mounting the hardware.The location must allow easy disconnection of power to the radio if  ▪necessary.Air must be able to fl ow freely around the hardware. ▪The radio unit must be kept away from vibration and excessive heat. ▪The installation must conform to local regulations at all times. ▪The unit is designed to directly mount to a pole or wall. Using the supplied mounting clamps and hardware, you can mount the unit to a 1.25 inch to 4.5-inch pole (outside diameter). Using just one of the mounting clamps brackets, you can mount it to a wall or other fl at surface.Caution!Proxim recommends the use of a lightning arrestor at the building ingress point. You can purchase the Proxim Lightning Protector; see the documentation that comes with the Lightning Protector for more information and installation instructions.
Page 10  Copyright © 2008 Proxim Wireless Step 2: Unpack the Shipping BoxUnpack the unit and accessories from the shipping box.1. Note the Ethernet and wireless MAC addresses of the unit, as well as the 2. serial number. The serial number is required to obtain support from Proxim. Keep this information in a safe place.All rights reserved  Page 23Set c.  IP Address Type to Static.Enter a static IP Address for the Mesh radio in the fi eld provided. d. You must assign the unit a unique address that is valid on your IP subnet. Enter your network’s e.  Subnet Mask.Enter your network’s f.  Gateway IP Address.Enter the SNMP read/write password in the g.  Read/Write Password fi eld. For new units, the default password is public.Click h.  OK to save your changes. The Access Point will need to reboot to apply any changes you i. made. When the reboot message appears, click OK to reboot the device and return to the Scan List screen.After allowing suffi cient time for the device to reboot, click j. Rescan to verify that your changes have been applied.Click the k.  Change button to return to the Change screen. Click the l.  Web Confi guration button at the bottom of the Change screen.Proceed to the m.  Logging In section, below. Logging InOnce the Mesh radio has a valid IP Address, you may use your web browser to monitor and confi gure the Mesh radio. (To confi gure and monitor using the command line interface, see the MeshMAX 5054 User Guide.)
Page 22  Copyright © 2008 Proxim Wireless Note:If your unit does not appear in the Scan List, click the Rescan button to update the display. If the unit still does not appear in the list, see the Troubleshooting chapter in the MeshMAX 5054 User Guide for suggestions. Note that after rebooting an Access Point, it may take up to fi ve minutes for the unit to appear in the Scan List.Do one of the following:4. If the Mesh radio has been assigned an IP address by a DHCP server on  ▪the network:Highlight the entry for the unit you want to confi gure.a. Click the b.  Change button. The Change screen appears (see below).Click on the c.  Web Confi guration button at the bottom of the change screen.Proceed to the d.  Logging In section, below.If the Mesh radio has not been assigned an IP address (in other words,  ▪the unit is using its default IP address, 169.254.128.132), follow these steps to assign it a static IP address that is valid on your network:Highlight the entry for the unit you want to confi gure.a. Click the b.  Change button. The Change screen appears.All rights reserved  Page 11Step 3: Assemble the CableUse the Cable Termination Kit to assemble the cable. You will be attaching an outdoor-rated 24 AWG CAT5 cable (diameter .114 to .250 inches/2.9 to 6.4 mm) (not provided) to the Power-over-Ethernet port on the back of the unit and weatherproofi ng the assembly later in the installation procedure.  First, you must construct the cable and assemble the weatherproofi ng cable covers as described in the following steps. Proxim greatly simplifi es this assembly process by offering pre-assembled CAT5 cable kits in 25m, 50m, and 75m lengths (part numbers 69819, 69820, and 69821, respectively).Slide the sealing nut (A) over the bare end of the CAT5 cable.1. Slide the lock nut (B) over the bare end of the CAT5 cable.2. Slide the sealing cap (C) over the bare end of the CAT5 cable. Make sure 3. the red rubber gasket is inside the cap.Apply two wraps of 0.5” wide Tefl on tape (not supplied with unit) around 4. the threads of the lock nut (B) that will go inside the sealing cap.Thread the lock nut (B) onto the sealing cap (C), and hand tighten.5. Terminate the RJ45 connectors (D) to both ends of the CAT5 cable; test for 6. proper wiring (using a straight-through cable).Notes:The cable must feed through all parts of the weatherproof cap before the  ▪RJ45 is crimped on the outdoor Ethernet cable. The cable between the power injector and the unit must be a straight- ▪through Ethernet cable (without crossover).Due to variance in CAT5 cable diameter, termination techniques of the  ▪installer, and the application of proper tightness of the connectors, it is strongly recommended that all cable connectors are secured by external weatherproofi ng. This process will be described in Step 10: Weatherproof the Connectors.
Page 12  Copyright © 2008 Proxim Wireless Step 4: Assemble Mounting Hardware Attach the mounting plate (A) using the provided screws and washers 1. (Torque 9 N∙m/75 in-lbs)Attach the extension arm (B) to mounting piece (A) with the screw, nut, 2. and washers. Attach the mounting bracket (C) to extension arm (B) with the screw, nut, 3. and washers provided.Tighten assembly (Torque 15 N∙m/130 in-lbs).4. The following fi gure shows the full assembly attached to the unit.All rights reserved  Page 21UNIT INITIALIZATIONMesh InitializationUsing ScanToolScanTool is a software utility that is included on the installation CD-ROM. It is an initial confi guration tool that allows you to fi nd the IP address of an Access Point by referencing the MAC address in a Scan List, or to assign an IP address if one has not been assigned.The tool automatically detects the MeshMAX units installed on your network, regardless of IP address, and lets you confi gure each unit’s IP settings. In addition, you can set initial device parameters that will allow the Mesh radio to retrieve a new software image if a valid software image is not installed.To access the HTTP interface and confi gure the Mesh unit, the unit must be assigned an IP address that is valid on its Ethernet network. By default, the Mesh unit is confi gured to obtain an IP address automatically from a network Dynamic Host Confi guration Protocol (DHCP) server during boot-up. If your network contains a DHCP server, you can run ScanTool to fi nd out what IP address the Mesh radios have been assigned. If your network does not contain a DHCP server, the IP address for the Mesh radios defaults to 169.254.128.132. In this case, you can use ScanTool to assign the unit a static IP address that is valid on your network.Scan Tool InstructionsPower up, reboot, or reset the unit.1. Double-click the ScanTool icon on the Windows desktop to launch the 2. program.  If the icon is not on your desktop, click Start > All Programs > Proxim > MeshMAX 5054 > ScanTool.Note:If your computer has more than one network adapter installed, you will be prompted to select the adapter that you want ScanTool to use before the Scan List appears. You can use either an Ethernet or wireless adaptor.  If prompted, select an adapter and click OK. You can change your adapter setting at any time by clicking the Select Adapter button on the Scan List screen. ScanTool scans the subnet and displays all detected units. The ScanTool’s Scan List screen appears, as shown in the following example.
Page 20  Copyright © 2008 Proxim Wireless Step 12: Install Documentation and SoftwareTo install the documentation and software on a computer or network:Place the installation CD in a CD-ROM drive. The installer normally starts 1. automatically. (If the installation program does not start automatically, click setup.exe on the installation CD).Follow the instructions displayed on the installer windows. 2. All rights reserved  Page 13Step 5: Mount the UnitCaution:To ensure that water does not gather around the antenna connectors, mount the unit with the antenna connectors facing downward.To pole-mount, insert the provided screws through bracket F. Fasten around 1. the pole to bracket E and secure (Torque 11 N.m/100 in-lbs).To wall-mount the unit, mount bracket (E) to the wall using 4 screws (not 2. provided), as shown.IMPORTANT!If the unit is going to be used as part of a Mesh network, you will need to perform initial confi guration of the parameters mentioned in the Pre-requisites section of this MeshMAX 5054 User Guide before you mount the unit. See the User Guide for more information on confi guring these parameters.
Page 14  Copyright © 2008 Proxim Wireless Step 6: Plug in the CablesPlug one end of the CAT5 cable (A) into the RJ45 jack of the unit (B).1. Connect the free end of the CAT5 cable to the “Data and Power Out” port 2. on the power injector. To connect the unit through a hub or a switch to a PC, connect a straight-3. through Ethernet cable between the network interface card in the PC and the hub, and between the hub and the RJ45 “Data In” port on the PoE adapter.To connect the unit directly to a PC, connect a cross-over Ethernet cable between the network interface card in the PC and the RJ45 “Data In” port on the power injector.If you are connecting the PC directly to the unit, use a crossover Ethernet cable between the network interface card in the PC and the RJ45 “Data In” port on the power injector.All rights reserved  Page 19Step 11: Align the AntennaAntenna Alignment Display (AAD) provides a measurement of signal quality in an easy-to-interpret manner - a numeric printed signal value at the CLI amd serial ports. The SNR is numerically displayed on the CLI serial port by two decimal charaters representing a number from 00 to 99. On the serial port, AAD is enabled by default after booting.To start the display, you must enable AAD and a wireless link must be established between the BSU and the SU.Aiming is complete if moving in any direction results in a falling SNR value.Antenna alignment commandsThe following CLI commands are used to initiate and stop the antenna alignment process. After the process has been successfully initiated, the CLI displays the current-local/current-remote/average SNR values (in 500 ms intervals) to indicate the link quality.Set aad enable localEnables display of the local SNR (the SNR as measured by the receiver at the far end).Set aad enable remoteEnables display of the remote SNR (the SNR as measured by the receiver at the far end).Set aad enable averageEnables display of the remote SNR (the average of local and remote SNR).Set aad disableDisables Antenna Alignment Display (Ctrl-C also disables AAD).
Page 18  Copyright © 2008 Proxim Wireless Step 10: Weatherproof the ConnectorsAfter you have fully assembled and tightened the cable, use the provided self-fusing, rubber-based tape strip and electrical tape (not provided; Proxim recommends Scotch™ Super 33+ Vinyl Electrical Tape) to seal the connection, as follows.Remove the fi lm liner from the rubber-based tape strip, and stretch the 1. tape until it is approximately half of its original width. This activates the self-fusing action of the tape, which will set up over time to create a single, waterproof mass.Stretch and wrap the tape around the connector tightly, starting below the 2. connector cap and against the unit and wrapping in a clockwise direction.  Wrap the tape once around the base of the connector cap (A). Continue to wrap the tape spirally around the connector in a clockwise direction, maintaining a 50% width overlap (B).  Continue wrapping the tape spirally upward (C) until the tape extends onto the cable and you have used the entire length of tape. Seal the tape tightly against the connector and the cable (D).Note:Be sure to wrap the tape in a clockwise direction; wrapping the tape in a counterclockwise direction may loosen up the connector.In the same manner as described in Step 2 above, apply a layer of black 3. electrical tape (not provided) over the rubber-based tape for further protection.  Make sure the electrical tape also extends beyond the rubber-based tape to seal it.Repeat the weatherproofi ng procedure for other connectors as appropriate.4. All rights reserved  Page 15Step 7: Power on the UnitThe power injector provides Power-over-Ethernet (PoE), supplying electricity and wired connectivity to the unit over a single 24 AWG CAT5 (diameter .114 to .250 inches/2.9 to 6.4 mm). The unit is not 802.3af-compatible. Always use the supplied power injector to ensure that the unit is powered properly. Note that the Active Ethernet module provides +48 VDC over a standard CAT5 Ethernet cable.Once you have connected the power injector to the Ethernet cabling and plugged the power injector cord into an AC outlet, the unit is powered on.  There is no ON/OFF switch on the unit. To remove power, unplug the AC cord from the AC outlet or disconnect the RJ45 connector from the “Data and Power Out” port on the power injector.Press the Reload button (on the side of the power injector) for fi ve seconds during power-up remotely resets the Mesh radios to their factory default settings. You will need to use the end of a pin or paperclip to depress the button.WARNING!To avoid damaging your router/switch, do not connect the RJ45 port labeled either “Data & Power Out” from the power injector to your router/switch.Press the Reload button (on the side of the power injector) to intiate the Reload/Reset functionality. You may have to use the end of a pin or paperclip to press the button. If the Reload button is pressed for 5 to 10 seconds and then released, then Mesh module moves to the bootloader state. If Reload button is pressed beyond 10 seconds, then the Mesh module’s Reload functionality is ignored.If the Reload button is pressed for 10 to 20 sconds and released, then none of the operation is performed and the Reload button is aborted.If the Reload button is pressed for 20 seconds and above, then the Subscriber module moves to reload state.NOTE:Bootloader will display all events to the serial console, which will guide user to perform the Reload functionality.
Page 16  Copyright © 2008 Proxim Wireless Step 8: View LEDsThe LEDs are present at the unit’s Ethernet connector; unscrew the watertight cap if necessary to view the LEDs.  NOTE: Make sure the domed sealing nut is loose before unscrewing the cap or the Ethernet cable may be twisted and damaged.When the unit is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the unit’s operational state, as follows:LED State Power/Ethernet LED Radio LEDBlinking Green Power is on, unit is booting up, Ethernet  link is down.Mesh radios are being initialized.Steady Green Power is on, Ethernet  link is up. Mesh radios are being operational.All rights reserved  Page 17Step 9: Tighten the CablesApply two wraps of Tefl on tape around the threads of the unit’s RJ45 jack 1. (A) in a clockwise direction.Make sure that the red rubber gasket is still seated in the sealing cap of the 2. sealing cap/lock nut assembly (B).Slide the sealing cap/lock nut assembly (B) over the RJ45 jack (A) and 3. thread onto enclosure. Hand tighten fi rst, then use a pipe wrench or similar tool to tighten one more quarter turn.Caution! Do not over-tighten!Tighten the lock nut (C) (Torque 4 N.m/35 in-lbs).4. Thread the sealing nut (D) onto the sealing cap/lock nut assembly (B) and 5. tighten (Torque 3 N.m/25 in-lbs).Caution!The lock nut (C) on the sealing cap/lock nut assembly (B) must be fully tightened over the RJ45 connector before the sealing nut (D) is fully tightened. Otherwise, the Ethernet cable may twist and damage.

Navigation menu