Paxton Access 333210 Compact Proximity Reader P38 User Manual INSTRUCTION PROXIMITY P series compact reader

Paxton Access Ltd Compact Proximity Reader P38 INSTRUCTION PROXIMITY P series compact reader

Contents

Installation manual

24/11/2011Technical SupportTechnical help is available:     Monday - Friday from 07:00 - 19:00 (GMT)                                 Saturday from 09:00 - 13:00 (GMT)01273 811011 support@paxton.co.ukSuitabilityMounted on metal surfaceWet environmentsSecurity-sensitive doorsReaders mounted togetherbetween readers300 mm Quickstart guideThis supplement is a brief guide to installing a P series compact system.  Further information is available for download at:  http://www.paxton.co.uk/ or call the communications team on:  01273 811011.Ins-30003 PROXIMITY P series compact readerExit button(push to make)Electric release12V DC power supply12V DC release current rating must be less than 1A. P75 Screw connector option The unit should be mounted in conjunction with an electrical backbox to achieve the required clearance for the connector.If an adaptor plate (310-750) is tted, the mountings on the backbox can also be used.Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/+12V +12V 0V 0V 0V ExitPaxtonIndoor use only
+12V DC 0V Lock 12VLock 0VExit inputExit 0VEnrolment Card - must be presented when the system is rst powered onBEEP!BEEP!2 3 41. At installation, present this card to the reader to validate the tokens in this pack2. To re-validate a user token present thisenrolment card to the reader followed by the user tokenPaxton AccessFUNCTION CARDenrolment cardMore info: http://paxton.info/741. At installation, present this card to the reader to validate the tokens in this pack2. To re-validate a user token present thisenrolment card to the reader followed by the user tokenPaxton AccessFUNCTION CARDenrolment cardMore info: http://paxton.info/7411. At installation, present this card to the reader to validate the tokens in this pack2. To re-validate a user token present thisenrolment card to the reader followed by the user tokenFUNCTION CARDenrolment card1. At installation, present this card to the reader to validate the tokens in this pack2. To re-validate a user token present thisenrolment card to the reader followed by the user tokenFUNCTION CARDenrolment cardMore info: http://paxton.info/741. Take the enrolment card from the new pack of user cards.2. Present the enrolment card to the reader.3. The reader beeps and the LED's light up as the enrolment card is acknowledged.4. All cards in the pack are now valid. The enrolment card can now be returned to it's pack.Reset - Use one methodReader covers Additional covers are available in black, white, grey, blue and silver. Registered installers can order these free of charge by logging onto the secure installer extranet: http://paxton.info/1035 or if you are not a registered installer please call us on: 01273 811011 for more information.FittingWiring1. Power down the unit.2. Press and hold the exit button.3. Power up the unit. It will give several quick beeps.4. Wait for a further beep and then release and press                 the exit button twice more.5. The reader will beep 3 times to conrm the reset.                             OR1. Present Enrolment card.2. Present Door open time card twice.3. Present Enrolment card.4. Present Door open time card twice.5. WAIT FOR 5 SECONDS!
Issuing tokens1. Across each double page there are pairs of cards - a user card and a corresponding shadow card.2. Write the name of the user on the shadow card.3. Take the user card from the opposite pouch and issue to the user.4. Keep the card pack containing the shadow cards in a safe place.1234User cardsShadow cardsBar a user1. When a card is lost or stolen it is important to bar the card from your system to avoid unauthorized access.2. To bar a card or token take it's corresponding shadow card from the card pack.3. Present the shadow card to the reader. This will remove the lost card or token from your system.4. A barred card can re-validated by presenting the enrolment card followed by the user card to the reader.1 2 3 4Fail open release card - Compact systems are fail closed as defaultTHIS CARD CAN ONLY BE USED WITH A FAIL OPEN LOCK.1. Take the fail open release function card from the starter pack.2. Present/swipe the card through the reader. The reader will beep for about a second.3. The reader is now set to fail open mode. This allows safe operation of the door in case of re: The lock will     release when the power is cut.4. To revert to fail closed mode, swipe the card again and the reader will beep once.1  2  34 BEEP! BEEP!    This card is used with systems where a fail openelectric release is used for the safe operation in the event of a fire.  Present the card to the reader todrive a fail open release or a maglock.  Present the card again to revert to the fail closed operationPaxton AccessFUNCTION CARDfail open releaseThis card is used with systems where a fail openelectric release is used for the safe operation in the event of a fire.  Present the card to the reader todrive a fail open release or a maglock.  Present the card again to revert to the fail closed operationPaxton AccessFUNCTION CARDfail open releaseThis card is used with systems where a fail openelectric release is used for the safe operation in the event of a fire.  Present the card to the reader todrive a fail open release or a maglock.  Present the card again to revert to the fail closed operationFUNCTION CARDfail open release1. Power down the unit.2. Press and hold the exit button.3. Power up the unit. It will give several quick beeps.4. Wait for a further beep and then release and press                 the exit button twice more.5. The reader will beep 3 times to conrm the reset.                             OR1. Present Enrolment card.2. Present Door open time card twice.3. Present Enrolment card.4. Present Door open time card twice.5. WAIT FOR 5 SECONDS!
11V DC   14V DC100mA1A-20 °C +55 °CIPX7110,0001 1001 sec 60 secs1 21 3P38 60 mm 40 mm 25 mmP50 80 mm 50 mm 35 mmP75 100 mm 60 mm 40 mmP38 38 mm 78 mm 13 mmP50 50 mm 100 mm 15 mmP75 75 mm 143 mm 16 mmVoltage Specications Operating temperatureElectrical Environment Dimensions Min  Max Width  Height  Depth Current Outdoor use FeaturesDoor open time Number of Card Packs Time zones (with additional time clock) Silent operationCan be used with fail OPEN locks Can be used with fail CLOSED locks Exit button input Waterproof - Fixed cableNumber of Users Access levels (Colour Zones) Door open time (seconds) 1. Take the silent operation function card from the starter pack.2. Present the card to the reader. The reader will beep.3. The reader is now in silent operation mode.4. Present the card again to disable silent operation mode. The reader will beep twice.Silent operation1. Take the 'door open time' card from the starter pack.2. Present the card to the reader. The reader will start beeping.3. Wait for the required period you wish the door to remain open.4. Present the card again at the end of the period to set the open time. The beeping will stop.1  2  3  4 BEEP! BEEP!BEEP!Paxton AccessFUNCTION CARDsilent operationPresent this card to silence the beeping noisesmade by the reader.  Present this card again to re-enable the beeping noisesPaxton AccessFUNCTION CARDsilent operationPresent this card to silence the beeping noisesmade by the reader.  Present this card again to re-enable the beeping noisesFUNCTION CARD silent operation Present this card to silence the beeping noises made by the reader.  Present this card again to  re-enable the beeping noises 1  2  3  4 BEEP! BEEP! Paxton AccessFUNCTION CARDdoor open time cardThe period that the door is unlocked for when a valid token is presented is set as follows:1.  Present this card2.  Wait for the required period 3.  Present this card again, the beeping will stopPaxton AccessFUNCTION CARDdoor open time cardThe period that the door is unlocked for when a valid token is presented is set as follows:1.  Present this card2.  Wait for the required period 3.  Present this card again, the beeping will stopFUNCTION CARD door open time card The period that the door is unlocked for when a  valid token is presented is set as follows: 1.  Present this card 2.  Wait for the required period  3.  Present this card again, the beeping will stop Switchable current Min Min Max Max Read Range KeyfobToken Watchprox Yes Yes Yes Yes Waterproof - P75 - Screw connection  Indoor use