Paradox Security Systems EVO641R Alarm system keypad with card reader User Manual

Paradox Security Systems Alarm system keypad with card reader

User Manual

User GuideFor EVO SystemsWe hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.EVO641 / EVO641RDGP2-641BL / DGP2-641RB DGP2-648BL
Table of ContentsIntroduction ....................................... 1Legend ..............................................................1Basic Operation ................................. 2Confidential Mode  .............................................3Partitioned System ............................ 4Area Display ......................................................4Arming ................................................ 5Exit Delay Timer ................................................5Regular Arming  .................................................5Stay Arming  ......................................................5Instant Arming ...................................................5Force Arming  ....................................................5Bypass Programming ........................................5Keyswitch Arming  .............................................6Auto-Arming ......................................................7Disarming ........................................... 8Entry Delay Timer  .............................................8Disarming an Armed System  ............................8Alarm Memory Display ......................................8Access Codes .................................... 9System Master Code (Default 123456) .............9Copy User Options ............................................9User Labels .......................................................9Deleting User Access Codes  ..........................11Programming User Access Codes ..................11User Options  ...................................................13Access Control User Options ..........................13Using Access Control ..................... 15Entering & Exiting  ...........................................15Arming and Disarming with Card  ....................15How Access Control Works  ............................16Trouble Display  ............................... 17Trouble Display ...............................................17Event Record Display  .....................................18Additional Features ......................... 19Programmable Outputs (PGMs) .....................19Keypad Settings ..............................................19Modifying illumination settings on the DGP2-648BL LED .....................................19Setting Time & Date ........................................19Programming Chime Zones ............................20Panic Alarms ...................................................20Quick Function Buttons ...................................20VDMP3 Plug-In Voice Dialer  ........... 21Calling the VDMP3 (outside line) ....................21Receiving a Call From the VDMP3 (alarm in system)  ............................................21Testing and Maintenance ............... 23Burglar Alarm Testing  .....................................23Fire Alarm Testing ...........................................23System Maintenance  ......................................23System Test ....................................................23Fire and Burglar Alarms ................. 24Standard Fire Zone .........................................24Delayed Fire Zone  ..........................................24Fire Safety Tips ...............................................24Minimizing Home Fire Hazards .......................25Home Fire Warning System ............................25Burglar Alarm ..................................................25Appendix 1: Hebrew Special Characters  ........26Appendix 2: Russian Special Characters ........27Appendix 3: Greek Special Characters ...........28Index ................................................. 29
 EVO Systems 11.0 IntroductionYour EVO System is an advanced technology security system that will provide you with reliable security protection and powerful features that are easy to use. The elegant and user-friendly keypads will allow you easy access to your security system's functions and information at the touch of a button. Messages will be displayed differently depending on the keypad you have selected.The 32-character screen on LCD keypads will display messages and menus to guide you through the system’s operations. Your installer can even customize the messages on LCD keypads for your home or business.The LED display of the DGP2-648BL LED will let you assess the system status at a glance.  Since you will communicate your instructions to your system through the keypad, please read this manual carefully and have your installer explain basic system operation.1.1 LegendIndicates a warning or an important note.Indicates useful information or a tip.[TEXT]  Indicates information that must be entered on the keypad.Indicates an LCD Keypad instruction or information.Indicates a DGP2-648BL instruction or information.LCD LEDLCDLED
2 User Guide  2.0 Basic OperationThe following sections will introduce you to the roles of the buttons, lights, and messages on your keypad.Figure 1: LCD Keypad Basic OverviewFigure 2: DGP2-648BL LED Keypad OverviewThe LCD screen will guide you with detailed messages.Use the arrow buttons to scroll through the current menu when the arrows appear in the LCD screen.AC Light:ON  = AC powerOFF  = Power failureSTATUS Light:When Green:ON  = All zones are closed.OFF  = One or more zones are open.FLASH  = Exit Delay in progressWhen Red:ON = Area(s) armedOFF = Area(s) disarmed The keypad will display the status of all its assigned areas.ACTION Lights: (Access, Stay, Force, Byp, Mem, Trbl and Prg)Lights will illuminate according to the status of the system.Numerical Lights: (Zones) ON  = Zone is openOFF  = Zone is closed (OK)FLASHES  = Zone / fire loopAC Light:ON = AC Power (OK)OFF  = Power failureAREA Lights: (A1, A2, A3 and A4)ON = Area armedOFF = Area disarmedFLASH  = Area in alarmSTATUS Light:When green:ON  = All zones closedOFF  = One or more zones are openFLASH  = Exit Delay in progressWhen red:ON  = Area(s) armedOFF  = Area(s) disarmedFLASH = System in AlarmFor all keypads, the [ENTER] key will save and exit, and the [CLEAR] key will exit without saving. [ENTER] and [CLEAR] represent the LCD/LED keypads’ enter and clear keys unless both keys are shown to have a different function.
 EVO Systems 32.1 Auditory Feedback (Beep Tones)When you enter information on the keypad, the keypad will guide you with beep tones to communicate the acceptance or rejection of your entries. Confirmation Beep: When an operation (i.e. arming/disarming) is successfully entered or when the system switches to a new status/mode, the keypad emits an intermittent beep tone (“BEEP-BEEP-BEEP-BEEP-BEEP”).Rejection Beep: When the system reverts to a previous status, or when an operation is incorrectly entered, the keypad emits a continuous beep tone (“BEEEEEEEEEEP”).2.2 Confidential ModeYour installer can program keypads to not display the status of your system automatically by changing the keypad to Confidential Mode.In Confidential Mode:• The zones and status messages will NOT be displayed• The indicator lights will NOT illuminate• Depending on how your keypad was programmed by your installer, you must either press a button or enter your user access code to illuminate the indicator lights and activate Normal Mode. LCD LEDLCD LED
4 User Guide  3.0 Partitioned SystemYour installer can set your keypad to recognize separate protected areas. A separated system is called a partitioned system, which can be useful in situations where shared security systems are more practical. For example, a company that has both an office and a warehouse area, can arm and disarm each area separately while controlling access to each area. Therefore, one person may have access to only one area, whereas another person may have access to all areas. Access to the areas is determined by the User Access Code.3.1 Area DisplayThe Area Status Display enables you to see the status of the individual areas within a partitioned system. Your installer can partition the system into separate areas. To view the status of the areas:1. Enter your [ACCESS CODE], and then press the [1] button.2. Press the button corresponding to the area (i.e. 1, 2,...8), or use the [S] and [T] buttons and press [ENTER] when the area you want to view appears on the screen.3. Press [CLEAR] to exit. In Area Status Display mode, the following information will scroll on the LCD screen:•ready: if all zones in the selected area are closed.•not ready: if zones in the selected area are open.•Front Door Open: if there is an open zone within that area.•Trouble(s): (section 8.0 on page 17) if a trouble has occurred.•Alarms in Memory: (section 5.3 on page 8) if an alarm has occurred.•Armed; Force Armed; Instant Armed; Stay Armed: displays the arming status of the selected area.In Area Status Display, the following will illuminate for the area selected:• The area lights (A1, A2, A3, and A4) if the associated area is armed. For example, if you have selected area 3 and it is currently armed, A3 will illuminate. • The numerical light(s) representing any open zone(s) in a corresponding area or areas. •The MEM action light if any alarms have occurred.•The TRBL action light if any troubles are occurring.•The STAY action light if the area is Stay or Instant Armed.•The FORCE action light if the area is Force Armed.•The BYP action light if zones are bypassed.LCDLED
 EVO Systems 54.0 ArmingWhen your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending a report to your monitoring station.4.1 Exit Delay TimerWhen you arm your system, it will trigger the Exit Delay Timer to provide you with enough time to exit the protected area before the system is armed. 4.2 Regular ArmingThis method is used for the everyday arming of your system. All zones within the protected area must be closed to Regular arm the system.To Regular arm the system:1. Enter your [ACCESS CODE]. 2. Press the [ARM] button. 3. If you have access to more than one area, select the area(s) you wish to Regular arm (refer to section 3.1 on page 4).4.3 Stay ArmingStay arming will partially arm your system to permit you to remain in your home or office by arming the outer zones (perimeter) of the protected area (i.e. doors and windows).To Stay arm: 1. Enter your [ACCESS CODE]. 2. Press the [STAY] button.3. If you have access to more than one area, select the area(s) you wish to Stay arm (refer to section 3.1 on page 4).4.4 Instant ArmingThis feature is the same as Stay arming except that there is no Entry Delay. Therefore, any armed zone that is breached will immediately generate an alarm.To Instant arm:1. Enter your [ACCESS CODE].2. Press the [5] button. 3. If you have access to more than one area, select the area(s) you wish to Instant arm (refer to section 3.1 on page 4).4.5 Force ArmingForce arming allows you to quickly arm your system when zones are open. However, once the open zone is closed, your system will then arm that zone as well.To Force arm:1. Enter your [ACCESS CODE]. 2. Press the [FORCE] button.3. If you have access to more than one area, select the area(s) you wish to Force arm (refer to section 3.1 on page 4).4.6 Bypass ProgrammingYou can bypass certain zones when you arm the protected area(s). When a zone is bypassed, it will be ignored the next time your system is armed. Once your area is disarmed, the system will unbypass the zone. To Bypass a zone:1. Enter your [ACCESS CODE].2. Press the [BYP] button. LCD LEDLCD LEDLCD LEDLCD LEDLCD LEDLCD LED
6 User Guide  3. Enter the zone number (i.e. 01, 02,...96), or use the [S] and [T] buttons and press [BYP] once the zone you want to bypass appears on the screen. If bypassed, the byp light does not appear on the screen and the keypad emits a rejection beep, you may not have access to bypass that zone.4. Repeat step 3 until all zones you want to bypass have been selected.5. Press the [ENTER] button to save and exit.To view all bypassed zones.1. Enter your [ACCESS CODE].2. Press the [BYP] button. 3. Scroll through the zones using the [S] and [T] buttons to view zone status. (LCD Keypads) In order to bypass a zone, the following conditions must be met:• The zone must have the Bypass option programmed by your installer.• The Bypass option must be enabled in your User Options.• Your user access code must have access to the zone’s Area Assignment.• The zone’s area must be disarmed before the zone can be bypassed.Fire Zones cannot be bypassed. 4.6.1 Bypass RecallBypass Recall reinstates the zones that were bypassed the last time your system was armed.To activate Bypass Recall:1. Enter your [ACCESS CODE]. 2. Press the [BYP] button. 3. Press the [MEM] button.Zones bypassed the last time your system was armed are bypassed. 4. Press the [ENTER] button to save and exit.4.6.2 One-Touch ButtonsIf enabled by your installer, you can access the following features without using your user access code by pressing and holding the desired One-Touch button.Table 1: One Touch Button4.7 Keyswitch ArmingA key can be used to arm and disarm your system using two forms of keyswitches. With a Maintained Keyswitch, place the key in the “ON” position to arm your system, and place the key in the “OFF” position to disarm your system. With a Momentary Keyswitch, place the key in the “ON” position briefly then place it back in the “OFF” position to arm the system. Repeat this process to disarm with a Momentary Keyswitch.LCD LEDButton Feature[ARM]Regular arm[STAY]Stay arm[FORCE]Force arm[BYP]Bypass Programming[DISARM]Disarm a Stay/Instant armed area[5] Instant arm[6] Change display settings[7] View Event Record display (LCD Keypads only)LCD LED
 EVO Systems 74.8 Auto-ArmingIf enabled by your installer, you can set the time that an area will arm itself automatically.4.8.1 Timed Auto-ArmingYour installer can set Timed Auto-Arming to function in either Force or Stay arming mode. A sixty-second (default value) Exit Delay sequence will begin prior to your system automatically arming itself at the programmed time. To set the Auto-Arming timer:1. Enter your [ACCESS CODE]. 2. Press the [0] button.3. Press the [MEM] button. 4. If you have access to more than one area, press the area’s number, or use the [S] and [T] buttons and press the [ACC] button when the area you want to program appears on the screen. 5. Enter the time you want the area to be armed according to the 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).6. Press the [ENTER] button to save and exit. If you are using the DGP2-648BL LED keypad, The MEM action light will flash if a time is not already programmed. The PRG action light, the area light of the chosen area, and the first number of the previous time set will illuminate (10 light = zero).4.8.2  No Movement Auto-ArmingYour system can be programmed to send a report to your monitoring station and/or arm the system if there is no activity in the area during a specified period of time. Your installer can set No Movement Auto-Arming to function in either Regular or Stay arming mode.LCD LED
8 User Guide  5.0 DisarmingWhen your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will not be triggered if zones are breached.5.1 Entry Delay TimerYour installer will program designated entry points (i.e. the front door) with an Entry Delay Timer. This delay gives you time to enter the armed premises and enter your code to disarm your system before the alarm is triggered. 5.2  Disarming an Armed SystemYou can only disarm an area to which your user access code is assigned. User access codes with the “Arm Only” (section 6.6 on page 13) option enabled cannot disarm an armed system.How do I disarm the system?1. Enter your [ACCESS CODE]. 2. Press the [DISARM] button. If you have access to more than one area, select the area(s) you wish to disarm (refer to section 5.2 on page 8).To disarm a system in alarm:1. Enter your [ACCESS CODE]. 2. In the case of a false alarm, call your monitoring station quickly to advise them of the false alarm.In the case of a burglar alarm, leave the premises and call the Police from a safe location.5.3 Alarm Memory DisplayWhen an alarm occurs in a zone:• The area and zone (i.e. Alarm Area 1 - Front Door) are displayed / zone’s LED flashes even when the system is armed. The notification continues until disarming, even if the zone is restored. (EVO641 / EVO641R only) • The alarm memory will be erased after the next alarm occurs and a valid code has been entered.To view the alarms that occurred the last time the system was armed:1. When the system is disarmed, the LCD keypad’s screen will display Alarm in Memory: Press [mem]. The DGP2-648BL LED’s MEM action light will illuminate. 2. Press the [MEM] button. Each zone that was breached while armed will appear below Alarm in:.The MEM action light will flash and the numerical light(s) for each zone whose alarm was triggered will illuminate.3. Press the [CLEAR] button to exit the Alarm Memory Display. LCD LEDLCD LEDLCDLED
 EVO Systems 96.0 Access CodesAccess Codes allow access to the system. Your system supports up to 999 user access codes. Codes are given a User Number between 002 and 999 (User Number 001 is the System Master Code). Your installer will program user access codes to be four, six, or variables of one to six digits in length. Each digit can be any value between zero and nine. If your installer programmed your system to accept a variable code length, you have to press the [ENTER] button after entering your user access code. 6.1  System Master Code (Default 123456) The System Master Code will give you access to all the features available on your system, as well as the ability to add, modify, or delete any user access codes. We suggest that you change this code to prevent others from accessing and changing  options without authorization. Your installer can set the System Master Code to be either 4 or 6 digits in length.To change the System Master Code:1. Enter the current [SYSTEM MASTER CODE] (default: 123456).2. Press the [0] button.3. Press the [ACC] button.4. Enter the numbers [0] [0] and [1].5. Enter a [NEW CODE].6. Press the [ENTER] button to save and exit.The System Master Code has access to all Access Control doors and all Access Control features at all times. Only the card’s serial number and the choice of arming method can be changed. If the other options are manually changed, the System Master Code will immediately revert to its original programming.You can assign a label (name) to a user access code at any point during the “Programming User Access Code” process. Refer to section 6.3 on page 9 to assign a User Label.6.2  Copy User OptionsThis feature allows you to copy the User Options, Access Control Options, and Area Assignments from one user access code to another. All User Options are copied except the User Code, Card Assignment, and User Label. To copy user options:1. Enter your [ACCESS CODE] (System Master Code or user access code with Master feature).2. Press the [0] button, and then the [ACC] button.3. Enter the 3-digit User number you wish to copy TO.4. Press the [MEM] button.5. Enter the 3-digit User number you wish to copy FROM. 6. Enter a user code. If the user code is of variable length, press the [ENTER] button after entering the user code. If necessary, assign an Access card (step 13 in section 6.5.1 on page 12) and User Label (section 6.3 on page 9).7. Press [ENTER] to save and exit.6.3 User LabelsUser labels personalize user access codes and can be assigned by pressing [ENTER] at any point after step 4 during the programming of user access codes (refer to section 6.5.1 on page 12). For Example, LCD keypads can display John Smith Select Action.To program a user label:1. At any point after step 4 in section 6.5.1 on page 12:2. Press the [ENTER] button. 3. Type the desired characters as detailed in section 6.3.1 on page 10 and section 6.3.2 on page 10.LCD LEDLCDLCD
10 User Guide  4. Press the [S] button to move the cursor to a new space.5. Repeat steps 2 and 3 until the desired label is complete.6. Press the [ENTER] button to save and exit.6.3.1 Keypad ButtonsEvery numeric button on the LCD keypads is assigned a set of letters. To obtain the desired letter using the numeric buttons on your keypad, press the button until the desired letter appears on the screen. For example, if you wanted to enter the letter “C” you would press the [1] button three times (refer to Table 2 on page 10). If using a Hebrew keypad, refer to Table 6 in Appendix 1: Hebrew Special Characters on page 26. If using a Russian keypad, refer to Table 8 in Appendix 2: Russian Special Characters on page 27. If using a Greek keypad, refer to Table 10 in Appendix 3: Greek Special Characters on page 28. Table 2: Keypad Letter Assignments6.3.2 Special Function Keys[STAY] = Insert SpacePressing the [STAY] key inserts a blank space in the current cursor position.[FORCE] = DeletePressing the [FORCE] key will delete the character or blank space found at the current cursor position.[ARM] = Delete Until the EndPressing the [ARM] key will delete all characters and spaces to the right of the cursor and at the cursor's position.[DISARM] = Numeric Keys / Alphanumeric KeysEvery time the [DISARM] key is pressed it will toggle from numeric keys to alphanumeric keys and vice versa. Numeric: Keys [0] to [9] represent numbers 0 to 9. [BYP] = Lower Case / Upper CaseEvery time the [BYP] key is pressed it will toggle the case setting from lower to upper case and vice versa. [MEM] = Special Characters After pressing the [MEM] key, the cursor will turn into a flashing black square. Using Table 3 on page 11, enter the 3-digit number that represents the desired symbol. If using a Hebrew keypad, see Hebrew Special Characters Catalogue on page 26. If using a Russian keypad, see Russian Special Characters Catalogue on page 27. If using a Greek keypad, see Greek Special Characters Catalogue on page 28Key Press KeyOnce Press Key Twice Press Key Three Times[1] A B C[2] D E F[3] G H I[4] J K L[5] M N O[6] P Q R[7] S T U[8] V W X[9] Y Z
 EVO Systems 11Table 3: Special Characters Catalogue6.4  Deleting User Access CodesTo delete user access codes, follow steps 1 to 5 in section 6.5.1 on page 12. Once the information is erased, press the [ENTER] button to save and exit.6.5  Programming User Access CodesThe System Master and Users with the Master feature can program user access codes with User Options and Area Assignments. The section 6.5.1 on page 12 describes the steps you would follow to program user access codes. If you wish to program user access codes using the NEware Software, please contact your installer for information.If the keypad emits a rejection beep at any point during the programming procedure, you may have chosen an existing user code or you do not have access to certain User Options (section 6.6) and Area Assignments (step 7 in section 6.5.1 on page 12). Users with the Master feature can only assign User Options and Area Assignments that they are assigned to. For example, if a User with the Master feature is assigned User Option 1 and Area 2, they can only assign Option 1 and Area 2 to a user access code. 032 048 064 080 096 112 128 144 160 176 192 208 224 240033 049 065 081 097 113 129 145 161 177 193 209 225 241034 050 066 082 098 114 130 146 162 178 194 210 226 242035 051 067 083 099 115 131 147 163 179 195 211 227 243036 052 068 084 100 116 132 148 164 180 196 212 228 244037 053 A069 085 101 117 133 149 165 181 197 213 229 245038 054 070 086 102 118 134 150 166 182 198 214 230 246039 055 071 087 103 119 135 151 167 183 199 215 231 247040 056 072 088 104 120 136 152 168 184 200 216 232 248041 057 073 089 105 121 137 153 169 185 201 217 233 249042 058 074 090 106 122 138 154 170 186 202 218 234 250043 059 075 091 107 123 139 155 171 187 203 219 235 251044 060 076 092 108 124 140 156 172 188 204 220 236 252045 061 077 093 109 125 141 157 173 189 205 221 237 253046 062 078 094 110 126 142 158 174 190 206 222 238 254047 063 079 095 111 127 143 159 175 191 207 223 239 255Polish 001 002 003 004 005 006 007Hungarian 001 002 003Turkish 001LCD LEDLCD LED
12 User Guide  6.5.1 Programming User SettingsLCD LEDNote:- For a detailed description of the Access Control NOTE: If no area is assigned, and if PGMs are programmed by your installer, the user can only control the PGMs. Refer to section 9.1 on page 19 for a more detailed explanation of PGMs.User Options, see section 6.7 on page User Labels on page 9.Notes:- For a detailed description of the User Options,  see section 6.6 on page 13.- By default, all users can regular arm the system.
 EVO Systems 136.6 User OptionsOptions [1] and [2]: Master FeatureWhen option [1] is OFF, the User cannot program other users into the system.When option [1] is ON and option [2] is OFF, the user can program and modify user access codes (P.I.N. only) and User Labels. When both options [1] and [2] are ON, the user has Full Master rights. The user can create or modify user access codes, User Options, User Access Control Options, Access Card Numbers, User Labels and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option [4] (Bypass) only, the Full Master user can only assign area #1 and option [4] to other users in the system. Option [3]: Duress When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.) reserved for the Duress feature, the system will arm or  disarm the area(s), and then send a silent alarm to the monitoring station. Option [4]: BypassWhen option [4] is ON, the Bypass feature is enabled. This feature allows the user to deactivate zones when arming the area(s).Option [5]: Arm Only When option [5] is ON, the Arm Only feature is enabled. The user can arm assigned areas with either a card or code, but cannot disarm. When the option is OFF, the user can either arm or disarm assigned areas.Option [6]: Stay & Instant Arm When option [6] is ON, the Stay and Instant arm features are enabled. The user can now Stay or Instant arm their assigned areas.Option [7]: Force Arm When option [7] is ON, the Force arm feature is enabled. The user can now Force arm their assigned areas.Option [8]: Area Access When option [8] is ON, the keypad will permit access to all the areas assigned to the user access code. When option [8] is OFF, the keypad will only permit access to the areas it controls. For example, the keypad is assigned area 1 only, and your user access code is assigned areas 1 to 8. If the option is ON, you can access all eight areas from the keypad. If the option is OFF, you can only access area 1. By default all users can Regular arm the system.6.7  Access Control User OptionsOption [1]: Access Control When option [1] is ON, the user can gain access to an access control door when Access Control is enabled in the system. A user that is not assigned to any partition, but has the Access Control option (Option [1]) enabled, can now gain access to an access control door by entering a code # (P.I.N.) and then pressing the [ACC] keypad key. When the option is OFF, the user cannot access an Access Control door.Option [2]: Can Disarm with Access CardWhen option [2] is ON, a User’s Access Control card can unlock and disarm an armed Access Control door. When option [2] is OFF, follow the settings in option [8] on page 15.For option [2] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 6.6 on page 13).LCD LEDLCD
14 User Guide  Option [3]: Card with Extended Unlocked PeriodWhen option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time period programmed into each Access Control door by your installer that extends the unlocked time of the door. For example, if your installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked Period to 15 seconds, a user access code with “Extended Unlocked Period” enabled will have a total of 45 seconds to pass through the door.   Options [4] and [5]: Arming with CardOptions [4] and [5] define the type of arming when arming with an Access Control card (refer to section 7.2.1 on page 15). You can either Regular arm, Stay arm, Force arm, or Disable the Arming with Card feature.[4] ON, [5] OFF = Regular Arm[4] OFF, [5] ON = Stay Arm[4] and [5] ON  = Force Arm[4] and [5] OFF = Disable the Arming with Card featureOption [6]: Add Tolerance Window to ScheduleWhen option [6] is ON, the Schedule Tolerance Window feature is enabled. This feature extends a user’s scheduled access period through an Access Control door by the amount programmed by your installer. For example, if the user’s assigned schedule for the door is Monday to Friday from 9:00 a.m. to 5:00 p.m., and your installer sets the “Tolerance Window” at one hour, the user with the “Schedule Tolerance Window” enabled will be able to enter and exit one hour before and after their scheduled time for that door.Option [7]: Code Follows ScheduleWhen option [7] is ON, users can use their access codes only during their scheduled hours assigned in step 8 in section 6.5.1 on page 12. When the option is OFF, users can use their access codes at any time.Option [8]: Card to Unlock and Code to Disarm Option [8] functions only if option [2] in section 6.7 is OFF. When option [8] is ON, a user can use an Access Control card to unlock an armed Access Control door, however the user must enter a user access code to disarm the armed area. When option [8] is OFF, a user can gain access to an Access Control door only if the door’s area(s) is already disarmed.For option [8] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 6.6 on page 13).
 EVO Systems 157.0 Using Access Control7.1  Entering & ExitingDepending on how your system is installed and on the type of keypad, there are various ways to enter and exit Access Control doors:• Present your Access Control card to the reader or the EVO641R or DGP2-641RB keypad. The system will verify that the card is allowed access according to its assigned Access Level and Schedule. If it is accepted, the system will unlock the door. The reader’s light can be programmed by the installer to turn green or extinguish briefly to indicate that the door can be opened.• When the motion detector detects movement (Request for Exit), it will unlock the door to permit passage from inside. • Enter your user access code on the keypad and press [ACC].• If the Access Control door is on a “Door Unlocked Schedule”, you may be able to open Access Control doors without using a user access code or an Access Control card. Depending on the door’s programming, the door can remain unlocked during the entire programmed schedule or the door can unlock once a valid Access Control card is presented to the reader during the schedule and then will remain unlocked for the remainder of the schedule. 7.2  Arming and Disarming with Card7.2.1 Arming with Card• presented to a door during its assigned Schedule (refer to step 8 in section 6.5.1 on page 12).• presented to a door within its assigned Access Level (refer to step 8 in section 6.5.1 on page 12).• programmed to allow arming (options [4] and [5] in section 6.7 on page 13).• assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 6.5.1 on page 12), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.7.2.2 Disarming with CardTo disarm and unlock an Access Control door when the area assigned to it is armed, present your Access Control card to the reader or EVO641R / DGP2-641RB keypad (door). The Access Control card must be:• presented to a door during its assigned Schedule (refer to step 8 in section 6.5.1 on page 12).• presented to a door within its assigned Access Level (refer to step 8 in section 6.5.1 on page 12).• programmed to allow disarming (option [2] in section 6.7 on page 13).• assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 6.5.1 on page 12), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.LCD LEDLCD EVO641R / DGP2-641RB only LCD EVO641R / DGP2-641RB only
16 User Guide  7.3  How Access Control WorksTo illustrate how Access Control functions, we will use three simple Access Control System examples:Figure 3:  Example ABonnie’s Access Control card is programmed with Access Level 01 and Schedule 01. If she presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on Tuesday, August 3 at 3:00 p.m., she will gain access to the room.Figure 4: Example BIf Bonnie presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on Saturday or on a Holiday at 3:00 p.m., she will be denied access.Figure 5: Example CIf we change Bonnie’s Access Level to 02 and she presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on Tuesday, August 3 at 3:00 p.m., she will be denied access.LCD LED
 EVO Systems 178.0 Trouble Display8.1 Trouble DisplayIf your system experiences any problems, Trouble(s) [TRBL] to View will appear on the screen, or the TRBL action light will illuminate. The Trouble Display will only display the troubles that occur in the area(s) to which the keypad has been assigned. Potential troubles have been sorted into eight groups. Only the troubles which are relevant to you are listed and described below. If a trouble that is not described or listed below appears, contact your installer. To view the Trouble Display:1. Press the [TRBL] button. The Group Heading with the trouble will appear on the screen. Press the [S] and [T] buttons to scroll between the Groups experiencing a trouble.On the DGP2-648BL LED keypad, The TRBL action light will flash and the numerical light(s) representing group heading number(s) will illuminate. 2.  Press the [NUMBER] of the Trouble you wish to view.We strongly suggest that if any troubles occur, contact your installer immediately to have your system serviced.8.1.1  Group 1: System[1] AC FailureThe control panel has detected a power failure. This means that your system is running on the backup battery. If this trouble occurs when your establishment is not experiencing a power failure, call your installer for repairs. [2] Battery TroubleThe backup battery is disconnected, needs to be recharged, or replaced. [5] Bell AbsentThe system has detected that the bell or siren is not connected.8.1.2  Group 2: Communicator[1] TLM1The control panel is unable to access the main telephone line.[2] to [5] Fail to Communicate (1 to 4)The control panel tried all assigned telephone numbers and failed to contact the monitoring station.[6] Fail to Communicate PCThe control panel is unable to communicate with the WinLoad software.8.1.3  Group 5: Zone Tamper The zone(s) that was tampered with will be displayed on the LCD screen.8.1.4  Group 6: Zone Low BatteryIf a wireless device's battery needs to be replaced, the zone that is assigned to the device will be displayed on the LCD screen. 8.1.5  Group 7: Zone FaultA wireless device is no longer communicating with its receiver, or a connection or CleanMeTM trouble is occurring with your smoke detectors.LCD LEDLCDLED
18 User Guide  8.1.6  Group 8: Clock Loss The time and date have been reset to the default. This is the only trouble that we recommend that you correct. Clock Loss [8] to Set will appear on the LCD screen after you press the [TRBL] button or the [] key. Refer to section 9.4 on page 19 to set the time and date.8.2 Event Record DisplayThe Event Record Display will record the user-initiated actions that occurred in your system as well as any alarms or troubles (i.e. “Access Granted”). You will only be able to view the events that occurred in the area(s) assigned to your user access code. -Only available on LCD keypads.To view the Event Record:1. Enter your [ACCESS CODE]. 2. Press the [7] button.3. If you have access to more than one area, select the area(s) you wish to view.4. Use the [S] and [T] buttons to scroll between the events. 5. Press the [CLEAR] button to exit.Once you have entered Event Record Display mode, you can change the order that the Event Record screens appear by pressing the [7] button. If you already know the number of the event you want to view, press the [MEM] button after step 3 above, and then enter the event's number.LCD
 EVO Systems 199.0 Additional Features9.1  Programmable Outputs (PGMs)Your system includes Programmable Outputs (PGMs) that can be programmed by your installer. A PGM triggers when a predetermined event or series of events occurs in your system. The PGMs can be programmed to reset smoke alarms, turn on light switches, open or close garage doors and much more. Ask your installer about this useful feature. 9.2 Keypad SettingsYou can modify the keypad settings to suit your needs. 1. Scrolling Speed refers to the amount of time that a message will remain on the screen before moving to the next message. 2. Backlight refers to the illumination behind the buttons and LCD screen. 3. Contrast refers to how dark or pale characters will appear on the screen. Figure 6: Modifying LCD screen settings on LCD Keypads9.3 Modifying illumination settings on the DGP2-648BL LEDTo modify illumination settings:1. Enter your [ACCESS CODE]. Your keypad will emit a Confirmation Beep. The ACCESS action light will flash. 2. Press the [6] key. Your keypad will emit a Confirmation Beep, the Prg action light will illuminate and the numerical light for the current setting will illuminate. 3. Use the [S] and [T] keys to increase or decrease the illumination. The range is between numerical light 1 to 8 (1 being the lowest and 8, the brightest).4. Press the [ENTER] key to save and exit.9.4  Setting Time & DateTo reset the time and date:1. Enter your [ACCESS CODE] and press the [TRBL] button.2. Press the [8] button. 3. To change the time, place the cursor under the number you want to change by using the [S] button and enter the time according to a 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00). 4. To change the date, place the cursor under the number you want to change and enter the correct date according to year/month/day. 5. Press the [ENTER] button to save and exit.LCD LEDLCD†   *This feature cannot be accessed via One-Touch Buttons (see section 4.6.2 on page 6).   †When keypad mute is enabled, only confirmation, rejection, and key-press beeps are audible.   ‡EVO641 / EVO641R only‡‡‡LEDLCD
20 User Guide  On the DGP2-648BL LED keypad, follow this procedure:1. Enter your [ACCESS CODE] and press the [TRBL] button.2. Press the [8] button. 3. Enter the hour and minutes according to the 24-hour clock (i.e. 9AM is 09:00 and 9PM is 21:00).4. Enter the correct date according to yyyy/mm/dd.5. Press [CLEAR].9.5 Programming Chime ZonesYou can program the keypad to emit a rapid, intermittent beep tone whenever designated zones are opened or only when opened between certain hours. These zones are referred to as Chime Zones. Your installer can also program your Chime zones to beep upon closure. How do I program chime zones?1. Enter your [ACCESS CODE].2. Press the [9] key.3. Press the [1] key to chime a zone. Enter the number corresponding to the zone to be chimed, or use the [S] and [T] buttons to scroll the list of zones. Press the [ACC] button to chime or unchime the zone that appears on the screen. Press [ENTER] to save.ORPress the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will start beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened (HH:MM).4. Press [CLEAR] to exit chime programming.9.6 Panic AlarmsYour system can be programmed to send an alarm to your monitoring station to request help from the police, a medical facility, the fire department, or anyone you wish when you press a predetermined combination of buttons. To generate a panic alarm, simultaneously press and hold the button combinations displayed in Table 4 on page 20. Your installer can program the alarm to be either silent or audible.Table 4: Panic Buttons9.7 Quick Function ButtonsYou will only need to use the Quick Function Buttons upon your installer’s or monitoring station's request. Only the System Master Code or user access codes with the Master feature enabled will be able to access these functions.To access the Quick Function Buttons:1. Enter your [ACCESS CODE]2. Press the [0] button.3. Press the:[STAY] to send a test report to the monitoring station.[FORCE] to call the WinLoad software.[ARM] to answer the WinLoad software.[DISARM] to cancel communication with the WinLoad software.LEDLCD LEDLCD LEDPanic Alarm Types Buttons to be pressed and held simultaneouslyEmergency Panic Press & hold the [1] and [3] buttonsAuxiliary Panic Press & hold the [4] and [6] buttonsFire Panic Press & hold the [7] and [9] buttonsLCD LED
 EVO Systems 2110.0 VDMP3 Plug-In Voice DialerThe VDMP3 is a voice-assisted module that can be programmed to call up to 8 telephone numbers in the event of an alarm. You can also call the VDMP3 from an outside line, enabling you to arm or disarm the system as well as activate up to 8 PGMs.10.1  Calling the VDMP3 (outside line)Connected to an answering machine:1. From an outside line, dial the telephone number to which the VDMP3 is connected.2. When the line rings, hang up the telephone.3. Dial the telephone number again within the time limit set by your installer.4. When the VDMP3 answers the line, you are prompted to enter your access code.5. Options are given to arm/disarm (1) and control features (PGMs) (2).Not connected to an answering machine:1. From an outside line, dial the telephone number to which the VDMP3 is connected.2. When the VDMP3 answers the line, you are prompted to enter your access code.3. Options are given to arm/disarm (1) and control features (PGMs) (2).10.2  Receiving a Call From the VDMP3 (alarm in system)When the VDMP3 calls because of an alarm in the system, the option is given to disarm the system or disconnect (##). If you hang up without disarming or disconnecting, the VDMP3 calls the next telephone number on its list (see Telephone Numbers in VDMP3 Setup Instructions).
22 User Guide
 EVO Systems 2311.0 Testing and Maintenance11.1 Burglar Alarm TestingTwo people are needed to complete this test. One person will watch the screen on the keypad while the other person walks around the protected areas and opens the zones (i.e. opens the doors and windows that are protected, walk in the path of the motion detectors, etc.). The screen will display the opened zones, but if a zone does not register, contact your installer.11.2 Fire Alarm TestingDo NOT use an open flame or burning materials to test your fire detection devices. Your installer will provide details on the best way to test your system.11.3 System MaintenanceUnder normal use your system requires no maintenance other than regular testing. We recommend that your installer change the battery every three years. 11.4 System TestSpeak to your installer before conducting a System Test since the system must be programmed to respond to the test instructions. It is normally recommended that you conduct the system test once a week, but contact your installer for instructions concerning your particular system.To conduct the system test:1. Call your monitoring station to advise them that you are testing your system.2. Enter your [ACCESS CODE].3. Press the [8] button. The system will test all its connections and can send a report to your monitoring station. If the system detects a problem, the Trouble Display will show on the  screen (refer to section 8.0 on page 17). Call your installer for repairs if any troubles occur.LCD LED
24 User Guide  12.0 Fire and Burglar Alarms12.1  Standard Fire ZoneDuring a fire alarm, the bell/siren emits an intermittent sound (BEEP-BEEP-BEEP) until silenced or reset. If the zone is a Standard Fire Zone, your system can immediately send an alert to your monitoring station. To disarm a false alarm:1. Enter your [ACCESS CODE] on the keypad.2. Call your monitoring station quickly to advise them of the false alarm.The Fire Zone may reset itself once the problem has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds.12.2  Delayed Fire ZoneIf the zone is a Delayed Fire Zone, there is an automatic delay before your system contacts your monitoring station. Refer to Figure 7 on page 25 to prevent unnecessary reporting of false alarms.If the fire alarm is accidentally triggered:1. Press the [CLEAR] button within 30 seconds of the alarm. 2. Clear the problem from the area (i.e. clear the smoke from around the smoke detector).3. If the problem remains after 90 seconds, the alarm will sound again. Press [CLEAR] again.4. The system will delay reporting the alert for another 30 seconds.If you are unable to cancel the false alarm, your system will send an alert. Call your monitoring station to advise them of the false alarm.The Fire Zone may reset itself once the smoke has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds or speak to your installer. 12.3  Fire Safety Tips How should you prepare in case of a fire in your home or business?• Remind everyone to escape first, and then call for help. • Develop a fire escape plan and designate a meeting place outside. • Practice the escape plan frequently.• Plan two ways to escape from every room, if possible. • Practice feeling the way out with eyes closed. • Instruct everyone never to stand up during a fire, always crawl under the smoke and keep mouths covered. • Instruct everyone never to return to a burning building for any reason; it may cost them their life.• Check smoke alarms regularly. Working smoke alarms dramatically increase everyone's chances of surviving a fire. LCD LEDLCD LED
 EVO Systems 25Figure 7: Delayed Fire Zone12.4  Minimizing Home Fire HazardsHow can you avoid the three most common causes of fires at home?• Never leave cooking food unattended. It’s the leading cause of fire injuries. Cooking fires often result from unattended cooking and human error, rather than mechanical failure. • Stay alert when smoking. Careless smoking is the leading cause of fire deaths. Smoke detectors and smoulder-resistant bedding and upholstered furniture are significant fire deterrents. • Maintain your heating system. Faulty heating systems are the second leading cause of residential fires. 12.5  Home Fire Warning System Household fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome occupants while they sleep. To warn against fire, install smoke detectors outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements.12.6 Burglar AlarmIf your armed system is breached, the burglar alarm devices specific to your system will be triggered. The feedback will vary depending on the type of keypad used. If your keypad is in Normal Mode:•In Alarm will appear on LCD screen.• Bell or siren may be activated.• The keypad may beep. The MEM action light will illuminate. In case of a burglar alarm, leave the premises and call the police station from a safe place.
26 User Guide  Appendix 1: Hebrew Special CharactersRefer to the following tables when programming the user labels of a Hebrew LCD keypad. Refer to section 6.3 on page 9 for information on programming user labels.Table 5: Hebrew Keypad Letter AssignmentTable 6: Hebrew Special Characters Catalogue032 048 064 080 096 112 160 176 192 208 224 240033 049 065 081 097 113 161 177 193 209 225 241034 050 066 082 098 114 162 178 194 210 226 242035 051 067 083 099 115 163 179 195 211 227 243036 052 068 084 100 116 164 180 196 212 228 244037 053 069 085 101 117 165 181 197 213 229 245038 054 070 086 102 118 166 182 198 214 230 246039 055 071 087 103 119 167 183 199 215 231 247040 056 072 088 104 120 168 184 200 216 232 248041 057 073 089 105 121 169 185 201 217 233 249042 058 074 090 106 122 170 186 202 218 234 250043 059 075 091 107 123 171 187 203 219 235 251044 060 076 092 108 124 172 188 204 220 236 252045 061 077 093 109 125 173 189 205 221 237 253046 062 078 094 110 126 174 190 206 222 238 254047 063 079 095 111 127 175 191 207 223 239 255
 EVO Systems 27Appendix 2: Russian Special CharactersRefer to the following tables when programming the user labels of a Russian LCD keypad. Refer to section 6.3 on page 9 for information on programming user labels.Table 7: Russian Keypad Letter AssignmentTable 8: Russian Special Characters Catalogue032 048 064 080 096 112 160 176 192 208 224 240033 049 065 081 097 113 161 177 193 209 225 241034 050 066 082 098 114 162 178 194 210 226 242035 051 067 083 099 115 163 179 195 211 227 243036 052 068 084 100 116 164 180 196 212 228 244037 053 A069 085 101 117 165 181 197 213 229 245038 054 070 086 102 118 166 182 198 214 230 246039 055 071 087 103 119 167 183 199 215 231 247040 056 072 088 104 120 168 184 200 216 232 248041 057 073 089 105 121 169 185 201 217 233 249042 058 074 090 106 122 170 186 202 218 234 250043 059 075 091 107 123 171 187 203 219 235 251044 060 076 092 108 124 172 188 204 220 236 252045 061 077 093 109 125 173 189 205 221 237 253046 062 078 094 110 126 174 190 206 222 238 254047 063 079 095 111 127 175 191 207 223 239 255
28 User Guide  Appendix 3: Greek Special CharactersRefer to the following tables when programming the user labels of a Greek LCD keypad. Refer to section 6.3 on page 9 for information on programming user labels.Table 9: Greek Keypad Letter AssignmentTable 10: Greek Special Characters CatalogueKey Press key once Press key twice Press key three times[1] #$)[2] &'<[3] *3 +[4] -./[5] 01[6] 245[7] 67([8] %;9016 032 048 064 080 096 112 128 144 160 176 192 208 224 240017 033 049 065 081 097 113 129 145 161 177 193 209 225 241018 034 050 066 082 098 114 130 146 162 178 194 210 226 242019 035 051 067 083 099 115 131 147 163 179 195 211 227 243020 036 052 068 084 100 116 132 148 164 180 196 212 228 244021 037 053 A069 085 101 117 133 149 165 181 197 213 229 245022 038 054 070 086 102 118 134 150 166 182 198 214 230 246023 039 055 071 087 103 119 135 151 167 183 199 215 231 247024 040 056 072 088 104 120 136 152 168 184 200 216 232 248025 041 057 073 089 105 121 137 153 169 185 201 217 233 249026 042 058 074 090 106 122 138 154 170 186 202 218 234 250027 043 059 075 091 107 123 139 155 171 187 203 219 235 251028 044 060 076 092 108 124 140 156 172 188 204 220 236 252029 045 061 077 093 109 125 141 157 173 189 205 221 237 253030 046 062 078 094 110 126 142 158 174 190 206 222 238 254031 047 063 079 095 111 127 143 159 175 191 207 223 239 255
29 User GuideIndexAAccess CodesDeleting .................................................................................. 11Labelling ................................................................................... 9Programming .......................................................................... 11System Master ......................................................................... 9User .......................................................................................... 9Access Control  ............................................................................... 13Entering & Exiting ................................................................... 15Access Control User OptionsAccess Control ....................................................................... 13Add Tolerance Window to Schedule ...................................... 14Arming with Card .................................................................... 14Can Disarm with Access Card ............................................... 13Card to Unlock and Code to Disarm ...................................... 14Code Follows Schedule ......................................................... 14Extended Unlocked Period ..................................................... 14Add Tolerance Window to User Schedule  ..................................... 14Alarm Memory Display  ..................................................................... 8Alarm,Testing ................................................................................. 23Area Access, in User Options  ........................................................ 13Area Display ..................................................................................... 4ArmingAutomatic Arming ..................................................................... 7Force Arming ............................................................................ 5Instant Arming .......................................................................... 5Keyswitch Arming ..................................................................... 6Regular Arming ........................................................................ 5Stay Arming .............................................................................. 5with Card ................................................................................ 15Auto-ArmingNo Movement Auto-Arming ...................................................... 7Timed Auto-Arming .................................................................. 7BBasic Operation ................................................................................ 2BatteryDisconnected ......................................................................... 17Low, in a Zone ........................................................................ 17Beep TonesConfirmation beep .................................................................... 3in Opened or Closed Zones, see Chime ZonesRejection beep ......................................................................... 3Bell Disconnected  .......................................................................... 17Burglar Alarms  ............................................................................... 25ButtonsOne-Touch ............................................................................... 6Quick Function ....................................................................... 20BypassBypass Recall .......................................................................... 6Programming ............................................................................ 5CCard, Access ControlArming with ............................................................................ 15Disarming with ........................................................................ 15Characters, Special ........................................................................ 11Chime Zones .................................................................................. 20Clock, Set Time and Date  .............................................................. 19Code Follows Schedule  ................................................................. 14Copy User Options  ...........................................................................9DDate, Set .........................................................................................19Deactivating a Security System ........................................................8Delay TimerEntry .........................................................................................8Exit ............................................................................................5Delayed Fire Zone  ..........................................................................24Deleting User Access Codes ..........................................................11DGP2-648BL LED Keypad Overview  ...............................................2DisarmingArmed System ..........................................................................8with Card ................................................................................15DisplayAlarms In Memory ....................................................................8User Actions in Memory .........................................................18Duress, in User Options  .................................................................13EEmergency Buttons  ........................................................................20Entering and Exiting, Access Control Doors ...................................15Entry Delay Timer .............................................................................8Erasing User Access Codes ...........................................................11Event Record Display .....................................................................18Exit Delay Timer  ...............................................................................5Extended Unlocked Period  .............................................................14FFire Delayed Fire Zone ..................................................................24Minimizing Home Fire Hazards ..............................................25Safety Tips ..............................................................................24Standard Fire Zone .................................................................24Warning System .....................................................................25Fire Alarm, Testing  .........................................................................23Force Arming  ....................................................................................5GGreek Special Characters  ..............................................................28HHebrew Special Characters ............................................................26IIgnoring Zones when Arming, see Bypass ProgrammingInstant Arming  ..................................................................................5KKeypad, LCDButtons .....................................................................................2Letter Assignment ...................................................................10Lights ........................................................................................2Messages .................................................................................2Settings ...................................................................................19Keyswitch Arming  .............................................................................6
EVO Systems  30MMaster Code  .................................................................................... 9Master Feature, in User Options .................................................... 13NNo Movement Auto-Arming  ............................................................. 7OOne Touch Button for the DGP-641BL/RB and the DGP-648  ......... 6One-Touch buttons  .......................................................................... 6Outputs, Programmable (PGM)  ..................................................... 19PPanic Alarms .................................................................................. 20Power Failure, see TroubleProgrammable Outputs (PGM) 19ProgrammingChime Zones ......................................................................... 20User Access Codes ......................................................... 11–13QQuick Function ButtonsAnswer Winload Sofware ....................................................... 20Call Winload Software ........................................................... 20Cancel Communication with Winload Software ..................... 20Send Test Report ................................................................... 20RRecall, Bypassed Zones  .................................................................. 6Regular Arming ................................................................................ 5Request for Exit  ............................................................................. 15Russian Special Characters  .......................................................... 27SSafety Tips, Fire ............................................................................. 24ScheduleCode Follows ......................................................................... 14Schedule Tolerance Window, see Add Tolerance to User ScheduleSiren Disconnected ........................................................................ 17Special Characters  ........................................................................ 11Special Characters, Greek ............................................................. 28Special Characters, Hebrew  .......................................................... 26Special Characters, Russian  ......................................................... 27Special Function Keys  ................................................................... 10Standard Fire Zone ........................................................................ 24Stay Arming  ..................................................................................... 5System Master Code  ....................................................................... 9System Test ................................................................................... 23TTampered Zones  ........................................................................... 17Testing and MaintenanceBurglar Alarm ......................................................................... 23Fire Alarm .............................................................................. 23System Maintenance ............................................................. 23System Test ........................................................................... 23Time, Set  ....................................................................................... 19Timed Auto-Arming .......................................................................... 7TimerEntry Delay ...............................................................................8Exit Delay .................................................................................5TroubleAC Failure ...............................................................................17Battery ....................................................................................17Bell/Siren Disconnected .........................................................17Clock .......................................................................................18Communicator ........................................................................17Fail to Communicate ...............................................................17Fail to Communicate PC .........................................................17Low Battery, Zone ..................................................................17System ....................................................................................17TLM1 ......................................................................................17Zone Fault ..............................................................................17Zone Tampering .....................................................................17UUnlocked Period, Extended  ............................................................14User Labels .......................................................................................9User OptionsAccess Control, see Access Control User OptionsArea Access ...........................................................................13Arm Only .................................................................................13Bypass ....................................................................................13Copy .........................................................................................9Duress ....................................................................................13Force Arm ...............................................................................13Master Feature .......................................................................13Programming ??– ....................................................................13Stay & Instant Arm ..................................................................13User Settings  ..................................................................................12VVDMP3 Plug-In Voice Dialer ...........................................................21ViewingAlarms In Memory ....................................................................8User Actions in Memory .........................................................18
 EVO Systems 31WarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. © 2002-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259, 5886632. Canadian and international patents may also apply. Digiplex, InTouch, WinLoad and NEware are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Limitations of Alarm SystemsIt must be understood that while your Paradox alarm system is highly advanced and secure, it does not offer any guaranteed protection against burglary, fire or other emergency (fire and emergency options are only available on certain Paradox models). This is due to a number of reasons, including by not limited to inadequate or improper installation/positioning, sensor limitations, battery performance, wireless signal interruption, inadequate maintenance or the potential for the system or telephone lines to be compromised or circumvented. As a result, Paradox does not represent that the alarm system will prevent personal injury or property damage, or in all cases provide adequate warning or protection.Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other emergencies, such other tools include but are not limited to insurance coverage, fire prevention and extinguish devices, and sprinkler systems.We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and developments.Warning for Connections to Non-Traditional Telephony (eg. VoIP)Paradox alarm equipment was designed to work effectively around traditional telephone systems. For those customers who are using a Paradox alarm panel connected to a non-traditional telephone system, such as “Voice Over Internet Protocol” (VoIP) that converts the voice signal from your telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as effectively as with traditional telephone systems. For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may be compromised. Or, if your VoIP connection becomes disabled, your telephone line monitoring feature may also be compromised. Other concerns would include, without limitation, Internet connection failures which may be more frequent than regular telephone line outages.We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non-traditional telephone system with your installation company. They should be able to offer or recommend measures to reduce the risks involved and give you a better understanding. FCC PART 15, Warnings: Information to userThis equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful to equipment intermittently, the user is encouraged to try to correct the interference by one or more of the following measures: (1) reorient or relocate the receiving antenna; (2) increase the separation between equipment and receiver; (3) connect the equipment to an outlet on a circuit other than the one to which the receiver is connected, or (4) consult the dealer or an experienced radio/tv technician for assistance.Caution:Changes or modifications not expressly approved by PARADOX SECURITY SYSTEMS could void the user’s authority to operate the equipment.
Printed In Canada - 06/2007                  paradox.com                  EVO-EU01For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.com.

Navigation menu