   Spectra 1759MG     - 1 -     Programming Guide1759MGSystem Programming GuideSoftware Version 2.0Default Installer Code0000 / 000000 (see section [281] on page 18)Default System Master Code1234 / 123456 (see section [301] on page 18)How Do I Enter Programming Mode?1) Press [ENTER].2) Enter your [INSTALLER CODE].3) Enter 3-digit [SECTION] you wish to program.4) Enter required [DATA].Decimal and Hexadecimal Programming TableTrouble DisplayPress the [TBL] or [TRBL] key to view the Trouble Display. Please note that the keypad can be programmed to emit a BEEP every 5 seconds whenever a new trouble condition has occurred. Press the [TBL] or [TRBL] key to stop the beeping.[1] - No Battery or Low Battery[8] - Timer Loss**[2] - Wireless Transmitter Low Battery[9] - Tamper or Zone Wiring Failure*[3] - Power Failure[10] - Telephone Line Monitoring Failure[4] - Bell Output Disconnected [11]/[STAY] - Fire Loop Trouble*[5] - Maximum Bell Current [12]/[BYP] - Module Loss[6] - Maximum Auxiliary Current [13]/[MEM] - Wireless Transmitter Supervision Loss*[7] - Communicator Report Failure [16]/[FORCE] and [TBL]/[TRBL] flashes - Keypad Fault* Press the illuminated key ([9], [STAY] or [MEM]) to view which zones are causing the trouble. Enter the Installer Code to clear Tamper troubles.** Press [8] to re-program the time.Value or Action What Do I Press?What Do I See?10-Zone LED 16-Zone LED LCDValues 1 to 9 [1] to [9] [1] to [9][1] to [9] [1] to [9]A (hex only) [0] [0 (10)] [10] 0B (hex only) [STAY][STAY][11] BC (hex only) [BYP][BYP][12] CD (hex only) [MEM][MEM][13] DE (hex only) [TBL] / [TRBL][TBL][14] EF (hex only) [PG] / [FNC1][PG][15] FExit Without Saving [CLEAR][ENTER] flashes [ARM1] & [STAY1] flash “SECTION [       ]”Erase Current Digit [FORCE]Displays next digit or next sectionSave Data (hex only) [ENTER]Advances to the next section
   Spectra 1759MG     - 3 -     Programming GuideTable of ContentsDefault Installer Code...................................................................................................................................................... 1Default System Master Code .......................................................................................................................................... 1How Do I Enter Programming Mode? ............................................................................................................................. 1Decimal and Hexadecimal Programming Table.............................................................................................................. 1Trouble Display ............................................................................................................................................................... 1Data Display Mode (LED Keypads Only) ........................................................................................................................ 5Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)............................................................................... 5Zone Programming.......................................................................................................................................................... 6System Timers ................................................................................................................................................................ 8Programmable Outputs ................................................................................................................................................... 9System Options............................................................................................................................................................. 12Communication Settings ............................................................................................................................................... 15Report Codes ................................................................................................................................................................ 16System Settings ............................................................................................................................................................ 18User Code Options........................................................................................................................................................ 18Reprogram All Modules................................................................................................................................................. 19Paradox Memory Key (PMC-3) ..................................................................................................................................... 194-PGM Output Modules V2.0 ............................................................................................................ 20PGM Programming........................................................................................................................................................ 20Printer Module V2.0........................................................................................................................... 21PGM Programming........................................................................................................................................................ 22Clock Programming....................................................................................................................................................... 22Voice-assisted Arm/Disarm Bus Module V2.0................................................................................ 23Wireless Features.............................................................................................................................. 24Zone Assignment .......................................................................................................................................................... 24Serial Number Display................................................................................................................................................... 24Signal Strength Display................................................................................................................................................. 24Remote Control User Assignment................................................................................................................................. 25Button Options............................................................................................................................................................... 25Remote Control Assignment ......................................................................................................................................... 26Zone Expansion Bus Modules ......................................................................................................... 27PGM Programming (SPC-ZX8 and APR3-ZX8 Only) ................................................................................................... 27User Operation .................................................................................................................................. 28Partitioning .................................................................................................................................................................... 28Programming Access Codes......................................................................................................................................... 28Programming Chime Zones .......................................................................................................................................... 29Keypad Muting .............................................................................................................................................................. 29Keypad Backlight (1686H and 1686V Only).................................................................................................................. 29Quick Function Keys ..................................................................................................................................................... 29Appendix A - Ademco CID Report Code List (Prog.) ..................................................................... 30Appendix B - Ademco CID Report Code List (All Codes).............................................................. 31Bus Module Connections ................................................................................................................. 32Printer Module (APR3-PRT1)........................................................................................................................................ 324-PGM Output Module (APR3-PGM4)  ......................................................................................................................... 334-zone expansion Bus Module (SPC-ZX4 and APR3-ZX4)  ......................................................................................... 33
Spectra 1759MG     - 4 -     Programming GuideVoice-assisted Arm/Disarm Bus Module (APR3-ADM2)............................................................................................... 348-Zone Expansion Bus Modules (SPC-ZX8 and APR3-ZX8)  ...................................................................................... 35Hardware Connections.....................................................................................................................  36Single Zone Inputs ........................................................................................................................................................ 36Connecting Fire Circuits, Keyswitches and PGMs........................................................................................................ 36Programming a Wireless Fire Zone .............................................................................................................................. 36Alarm Relay and PGM Connections ............................................................................................................................. 37Connecting More Than Two Keypads........................................................................................................................... 37AC Power & Backup Battery Connections .................................................................................................................... 37Spectra 1759MG PCB Layout....................................................................................................................................... 38
   Spectra 1759MG     - 5 -     Programming GuideData Display Mode (LED Keypads Only)View the section’s programming one digit at a time. Does not function with sections using Feature Select Programming. Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)The keypad’s zone number, EOL definition and anti-tamper switch are programmed through the keypad’s programming mode. To do so:PLEASE NOTE: After two minutes, the keypad exits programming mode.Key [1] - Keypad Zone SelectionKey [1] determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF (not illuminated), the keypad’s zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypad’s zone is Keypad Zone 2. Refer to the Zone Recognition Table on page 6 for more information.Key [1] OFF - Keypad Zone 1 (default)Key [1] ON - Keypad Zone 2Key [2] - EOL DefinitionKey [2] determines the keypad zone’s EOL definition. When key [2] is OFF (not illuminated), EOL is disabled and the keypad zone uses the on-board EOL resistor. When key [2] is ON (illuminated), EOL is enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra 1759MG PCB Layout on page 38 for more details).Key [2] OFF - EOL disabledKey [2] ON - EOL enabled (default)Key [3] - On-Board TamperKey [3] enables or disables the keypad’s on-board anti-tamper switch. When key [3] is OFF (not illuminated), the anti-tamper switch is disabled. When key [3] is ON (illuminated), the anti-tamper switch is enabled.Key [3] OFF - On-board anti-tamper switch disabledKey [3] ON - On-board anti-tamper switch enabledPLEASE NOTE: The keypad can be ordered with or without an anti-tamper switch. If the keypad has no anti-tamper switch, key [3] will be OFF by default. If the keypad has an anti-tamper switch, key [3] will be ON by default.How Do I Configure The Keypad?1) Press [ENTER]2) Enter your [INSTALLER CODE] (default: 0000 / 000000)3) Press the [PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds.4) Press the desired key ([1] to [3]. See below)5) Press [ENTER] to exit programming modeTo access the Data Display Mode, press the [ENTER] key after entering a section and before entering any data. The three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode.Each time the [ENTER] key is pressed, the keypad will display the next digit in the current section and will continue through all the following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature Select Method. Press the [CLEAR] key at any time to exit the Data Display Mode.
Spectra 1759MG     - 6 -     Programming GuideZone ProgrammingWhen programming zones, the zone assignments are dependent on where the detection devices are connected to in the system (see Zone Recognition Table). In installations that require using mostly the expansion inputs, refer to Reassign Keypad Zone 2 (see section [126] option [7] on page 12) and Reassign zones to expansion inputs (see section [126] option [8] on page 12)..Do not assign inputs from different modules to the same expansion input.   Zone Recognition TableOption [7]: OFFOption [8]: OFF Option [7]: ONOption [8]: OFF Option [7]: OFFOption [8]: ON Option [7]: ONOption [8]: ONControl PanelInput 1 = Zone 1 Zone 1 Zone 1 Zone 1Input 2 = Zone 2 Zone 2 Zone 2 Zone 2Input 3 = Zone 3 Zone 3 N/A N/AInput 4 = Zone 4 Zone 4 N/A N/AInput 5 = Zone 5 Zone 5 N/A N/AKeypadZone 1 =  Zone 6 Zone 6 Zone 3 Zone 3Zone 2 =  Zone 7 N/A Zone 4 N/AExpansionInput 1 =  Zone 8 Zone 7 Zone 5 Zone 4Input 2 =  Zone 9 Zone 8 Zone 6 Zone 5Input 3 =  Zone 10 Zone 9 Zone 7 Zone 6Input 4 =  Zone 11 Zone10 Zone 8 Zone 7Input 5 =  Zone 12 Zone 11 Zone 9 Zone 8Input 6 =  Zone 13 Zone 12 Zone 10 Zone 9Input 7 =  Zone 14 Zone 13 Zone 11 Zone 10Input 8 =  Zone 15 Zone 14 Zone 12 Zone 11= not displayed on 10-Zone LED KeypadsOption [7] = Reassign Keypad Zone 2Option [8] = Reassign zones to expansion inputs
   Spectra 1759MG     - 7 -     Programming GuideOnly the control panel’s on-board inputs can be defined as a Fire, Delayed Fire or a Keyswitch zone. The on-board zones are zones 01 to 05. To program a wireless fire zone, refer to Programming a Wireless Fire Zone on page 36.How Do I Program the Zones?1) Press the [ENTER] key2) Enter the [INSTALLER CODE] (Default: 0000 / 000000)3) Enter 3-digit [SECTION]4) Enter one digit from the Zone Definition table (see page 7)5) Enter one digit from the Partition Assignment table (see page 7) 6) Select one or more options from the Zone Options table (see page 7)7) Press the [ENTER] keySection Description ZoneDefinition PartitionAssignment Zone Options[001] = Zone 01: 1  2  3  4  5  6  7  8[002] = Zone 02: 1  2  3  4  5  6  7  8[003] = Zone 03: 1  2  3  4  5  6  7  8[004] = Zone 04: 1  2  3  4  5  6  7  8[005] = Zone 05: 1  2  3  4  5  6  7  8[006] = Zone 06: 1  2  3  4  5  6  7  8[007] = Zone 07: 1  2  3  4  5  6  7  8[008] = Zone 08: 1  2  3  4  5  6  7  8[009] = Zone 09: 1  2  3  4  5  6  7  8[010] = Zone 10: 1  2  3  4  5  6  7  8[011] = Zone 11: 1  2  3  4  5  6  7  8[012] = Zone 12: 1  2  3  4  5  6  7  8[013] = Zone 13: 1  2  3  4  5  6  7  8[014] = Zone 14: 1  2  3  4  5  6  7  8[015] = Zone 15: 1  2  3  4  5  6  7  8Defaults = Empty Partition 1 1 and 2 ON[FORCE] key = emptyZone DefinitionEmpty - Zone Disabled1 - Entry Delay 12 - Entry Delay 23 - Follow4 - Instant5 - 24Hr Burglary6 - 24Hr BuzzerAdditional definitions for on-board terminals:7 - Keyswitch8 - Fire 24Hr9 - Delayed Fire 24HrPartition AssignmentEmpty - Zone Disabled1 - Partition 12 - Partition 23 - Both PartitionsZone Options1 - Auto Zone Shutdown2 - Bypass Enabled3 - Stay Zone4 - 5 - Zone Alarm Typeoff off Audible alarm (steady)off on Audible alarm (pulsed)on off Silent alarmon on Generates a report only6 - Intellizone7 - Delay alarm transmission8 - Force ZoneKeyswitch Options1 - off = Maintainedon = Momentary2 - off = Regular Armon  = Stay ArmSecond DigitFirst Digit
Spectra 1759MG     - 8 -     Programming GuideSystem TimersSection # Decimal Value (000 to 255) Description Default[050]___/___/___ x 10 msec. ZONE SPEED (ZONE 1) 600 msec.[051]___/___/___ x 10 msec. ZONE SPEED (ZONE 2) 600 msec.[052]___/___/___ x 10 msec. ZONE SPEED (ZONE 3) 600 msec.[053]___/___/___ x 10 msec. ZONE SPEED (ZONE 4) 600 msec.[054]___/___/___ x 10 msec. ZONE SPEED (ZONE 5) 600 msec.[055]___/___/___ x 10 msec. ZONE SPEED (ZONE 6) 600 msec.[056]___/___/___ x 10 msec. ZONE SPEED (ZONE 7) 600 msec.[057]___/___/___ x 10 msec. ZONE SPEED (ZONE 8) 600 msec.[058]___/___/___ x 10 msec. ZONE SPEED (ZONE 9) 600 msec.[059]___/___/___ x 10 msec. ZONE SPEED (ZONE 10) 600 msec.[060]___/___/___ x 10 msec. ZONE SPEED (ZONE 11) 600 msec.[061]___/___/___ x 10 msec. ZONE SPEED (ZONE 12) 600 msec.[062]___/___/___ x 10 msec. ZONE SPEED (ZONE 13) 600 msec.[063]___/___/___ x 10 msec. ZONE SPEED (ZONE 14) 600 msec.[064]___/___/___ x 10 msec. ZONE SPEED (ZONE 15) 600 msec.[065]FUTURE USE[066]___/___/___ seconds (000 = follow Deactivation Event) PGM1 TIMER 5 sec.[067]___/___/___ seconds (000 = follow Deactivation Event) PGM2 TIMER 5 sec.[068]___/___/___ seconds (000 = follow Deactivation Event) GLOBAL PGM TIMER 5 sec.[069]___/___/___ seconds ENTRY DELAY 1 45 sec.[070]___/___/___ seconds ENTRY DELAY 2 45 sec.[071]___/___/___ seconds EXIT DELAY 1 30 sec.[072]___/___/___ seconds EXIT DELAY 2 30 sec.[073]___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIMER (PARTITION 1) 4 min.[074]___/___/___ minutes (000 = no bell on alarm) BELL CUT-OFF TIMER (PARTITION 2) 4 min.[075]___/___/___ x 15 minutes (000 = disabled) NO MOVEMENT TIMER (PARTITION 1) Disabled[076]___/___/___ x 15 minutes (000 = disabled) NO MOVEMENT TIMER (PARTITION 2) Disabled[077]___/___/___ seconds (minimum 10 sec.) ANSWERING MACHINE OVERRIDE DELAY Disabled[078]___/___/___ (000 = no answer, maximum = 15 rings) NUMBER OF RINGS 8 rings[079]___/___/___ x 2 sec. (minimum 32 sec.) TLM FAIL TIMER 32 sec.[080]___/___/___ seconds DELAY ALARM TRANSMISSION Disabled[081]___/___/___ (000 = 16, maximum = 16) MAXIMUM DIALING ATTEMPTS 8 attempts[082]___/___/___ seconds DELAY BETWEEN ATTEMPTS 20 sec.[083]___/___/___ seconds PAGER DELAY 5 sec.[084]___/___/___ seconds (minimum 10 sec.) INTELLIZONE DELAY 48 sec.[085]___/___/___ seconds RECENT CLOSING DELAY No delay[086]___/___/___ minutes POWER FAILURE REPORT DELAY 15 min.[087]___/___/___ days (000 = disabled) AUTO TEST REPORT Disabled[088]___/___/___ 000 to 127 = +1 to +127 seconds128 to 255 = -1 to -127 secondsCLOCK ADJUST Disabled[089]___/___/___ (000 = disabled, maximum = 15) AUTO ZONE SHUTDOWN COUNTER 5[090]___/___/___ minutes (000 = disabled) RECYCLE ALARM DELAY Disabled[091]___/___/___ (000 = disabled) RECYCLE ALARM COUNTER Disabled[092]___/___/___ attempts before locking (000 = disabled) KEYPAD LOCKOUT Disabled[093]___/___/___ minutes (000 = disabled) KEYPAD LOCKOUT DELAY Disabled[094]___/___/___ seconds (000 = disabled) PANIC LOCKOUT TIMER Disabled[095] ___/___/___ days (000 = disabled) CLOSING DELINQUENCY TIMER (PARTITION 1) Disabled[110]___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) AUTO TEST REPORT (TIME OF DAY)Disabled[111]AUTO-ARM TIME (PARTITION 1) Disabled[112]AUTO-ARM TIME (PARTITION 2) Disabled
   Spectra 1759MG     - 9 -     Programming GuideProgrammable OutputsEach PGM Deactivation event can be used as another start (activation) event if their respective PGM timer (see sections [066] to [068]) is programmed with a value other than 000.      Example: section [120] = 05  03  02: this means PGM1 will activate whenever partition 2 is Stay Armed.Section # Event Group # Sub-Group # Partition #[120] PGM 1 PGM Activation Event ___/___ ___/___ ___/___[121] PGM 1 PGM Deactivation Event ___/___ ___/___ ___/___[122]PGM 2 PGM Activation Event ___/___ ___/___ ___/___[123]PGM 2 PGM Deactivation Event ___/___ ___/___ ___/___[124]Global PGM Activation Event ___/___ ___/___ ___/___[125]Global PGM Deactivation EventUsed to activate PGMs on expansion modules & LCD keypads.___/___ ___/___ ___/___Event Group # Sub-Group #00 = Zone OK 01 to 15 = Zones 1 to 1599 = Any Zone01 = Zone Open 01 to 15 = Zones 1 to 1599 = Any Zone02 = Partition Status 00 = System not ready (Partition 1 only)01 = System ready (Partition 1 only)02 = Steady Alarm in Partition03 = Pulsed Alarm in Partition04 = Pulsed or Steady Alarm in Partition05 = Alarm in Partition Restored06 = Bell Squawk Activated (Partition 1 only)07 = Bell Squawk Deactivated (Partition 1 only)08 = Ground start (Partition 1 only)09 = Disarm Partition10 = Arm Partition11 = Entry Delay (breach when system is armed)99 = Any Sub-Group05 = Non-Reportable Events 00 = Telephone Line Trouble (Partition 1 only)01 = [PG] or [FNC1] key was pressed (Partition 1 only). This         option can also be used to reset smoke detectors.02 = Instant Arming03 = Stay Arming 04 = Force Arming05 = Fast Exit (Force & Regular Only)06 = PC Fail to Communicate (Partition 1 only)07 = Midnight (Partition 1 only)99 = Any Sub-Group (Partition 1 only, except 02 to 05)06 = Arm/Disarm with Remote Control 01 to 08 = Remote Controls 1 to 899 = Any Remote Control07 = Button Pressed on Remote (see button option “B” on page 25) 01 to 08 = Remote Controls 1 to 899 = Any Remote Control08 = Button Pressed on Remote (see button option “C” on page 25)  01 to 08 = Remote Controls 1 to 899 = Any Remote Control01 = Partition 102 = Partition 299 = Any PartitionThe Sub-Groups proceeded by “(Partition 1)” cannot be assigned to activate Partition 2.
Spectra 1759MG     - 10 -     Programming Guide09 = Button Pressed on Remote (see button option “D” on page 25) 01 to 08 = Remote Controls 1 to 899 = Any Remote Control10 = Bypass Programming 01 to 48 = User Code Numbers 001 to 04899 = Any User Code11 = User Activated PGM 01 to 48 = User Code Numbers 001 to 048  (Partition 1 only)99 = Any User Code12 = Zone with Delay Transmission Option Enabled is Breached 01 to 15 = Zones 1 to 1599 = Any Zone 13 = Arm with User Code 01 to 48 = User Code Numbers 001 to 04899 = Any User Code14 = Special Arm 00 = Auto Arming (timed/no movement)01 = Late to Close (Auto-Arming failed)02 = No Movement Auto-Arming 03 = Partial Arming (Stay, Force, Instant, Bypass)04 = One-Touch Arming05 = Arm with WinLoad Software07 = Closing Delinquency (Partition 1 only)99 = Any Sub-Group15 = Disarm with User Code 01 to 48 = User Code Numbers 001 to 04899 = Any User Code16 = Disarm After Alarm w/ User Code 01 to 48 = User Code Numbers 001 to 04899 = Any User Code17 = Cancel Alarm with User Code 01 to 48 = User Code Numbers 001 to 04899 = Any User Code18 = Special Disarm 00 = Cancel Auto Arm (timed/no movement)01 = Disarm with WinLoad Software02 = Disarm after alarm with WinLoad Software03 = Cancel Alarm with WinLoad Software99 = Any Sub-Group19 = Zone Bypassed on Arming 01 to 15 = Zones 1 to 1599 = Any Zone20 = Zone in Alarm 01 to 15 = Zones 1 to 1599 = Any Zone21 = Fire Alarm 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone22 = Zone Alarm Restore 01 to 15 = Zones 1 to 1599 = Any Zone23 = Fire Alarm Restore 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone24 = Special Alarm 00 = Emergency Panic01 = Auxiliary Panic02 = Fire Panic 03 = Recent Closing04 = Auto Zone Shutdown05 = Duress Alarm06 = Keypad Lockout99 = Any Sub-Group25 = Auto Zone Shutdown 01 to 15 = Zones 1 to 1599 = Any Zone26 = Zone Tamper 01 to 15 = Zones 1 to 1599 = Any Zone27 = Zone Tamper Restore 01 to 15 = Zones 1 to 1599 = Any ZoneEvent Group # Sub-Group #
   Spectra 1759MG     - 11 -     Programming Guide28 = System Trouble 01 = AC Loss: only after Power Failure Delay has elapsed (Partition 1 only)02 = Battery Failure (Partition 1 only)03 = Auxiliary current overload (Partition 1 only)04 = Bell current overload (Partition 1 only)05 = Bell disconnected (Partition 1 only)06 = Timer Loss (Partition 1 only)07 = Fire Loop Trouble (Partition 1 only)08 = Future Use09 = Module Fault (Partition 1 only)10 = Printer Fault (Partition 1 only)11 = Fail to Communicate (Partition 1 only)99 = Any Sub-Group (Partition 1 only)29 = System Trouble Restore 00 = TLM restore (Partition 1 only)01 = AC Loss restore (Partition 1 only)02 = Battery Failure restore (Partition 1 only)03 = Auxiliary current overload restore (Partition 1 only)04 = Bell current overload restore (Partition 1 only)05 = Bell disconnected restore (Partition 1 only)06 = Timer Programmed (Partition 1 only)07 = Fire Loop Trouble restore (Partition 1 only)08 = Future Use09 = Module Fault restore (Partition 1 only)10 = Printer Fault restore (Partition 1 only)11 = Fail to Communicate restore (Partition 1 only)99 = Any Trouble Restore (Partition 1 only)30 = Special Reporting 00 = System Power Up (Partition 1 only)01 = Test Report (Partition 1 only)02 = WinLoad Software Access (Partition 1 only)03 = WinLoad Software Access finished (Partition 1 only)04 = Installer enters programming mode (Partition 1 only)05 = Installer exits programming mode (Partition 1 only)99 = Any Sub-Group (Partition 1 only)31 = Wireless Transmitter Supervision Loss 01 to 15 = Zones 1 to 1599 = Any Zone 32 = Wireless Transmitter Supervision Loss Restore 01 to 15 = Zones 1 to 1599 = Any Zone33 = Arming with a Keyswitch 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone34 = Disarming with a Keyswitch 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone35 = Disarm after Alarm with a Keyswitch 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone36 = Cancel Alarm with a Keyswitch 01 to 05 = Zones 1 to 5 (on-board inputs)99 = Any Zone37 = Wireless Transmitter Low Battery 01 to 15 = Zones 1 to 1599 = Any Zone38 = Wireless Transmitter Low Battery Restore 01 to 15 = Zones 1 to 1599 = Any ZoneEvent Group # Sub-Group # Partition #80 = PGM follows Clock (APR3-PGM4 only) HH = hour according to 24hr. clock MM = minutes according to 24hr. clockEvent Group # Sub-Group #
Spectra 1759MG     - 12 -     Programming GuideSystem OptionsBold = Default Setting* Reassign Keypad Zone 2 and Reassign zones to expansion inputs change the zone numbering to increase the number of expansion inputs that can be displayed on 10-Zone LED Keypads. Refer to the Zone Recognition Table on page 6 and the Spectra 1759MG Reference & Installation Manual for details. Section [126]: General OptionsOptionOFF ON[1]Confidential Mode  N Disabled  N Enabled[2]To exit Confidential Mode   N Enter Access Code  N Press a Key[3]Confidential Mode timer  N 2 minutes  N 5 seconds[4]PGM1 normal state  N Normally Open (N.O.)  N Normally Closed (N.C.)[5]PGM2 normal state  N Normally Open (N.O.)  N Normally Closed (N.C.)[6]Global PGM normal state  N Normally Open (N.O.)  N Normally Closed (N.C.)[7]Reassign Keypad Zone 2*  N Disabled  N Enabled[8]Reassign zones to expansion inputs*   N Disabled  N EnabledSection [127]: General OptionsOptionOFF ON[1]Partitioning  N Disabled  N Enabled[2]Access code length  N 6-digits  N 4-digits[3]Keypad audible trouble warning  N Disabled  N Enabled[4]Lock System Master Code  N Disabled  N Enabled[5]Battery charge current  N 350mA  N 700mA[6]User Code 048 is a Duress Code  N Disabled  N Enabled[7]Alarm relay follows  N Bell Output  N Global PGM[8]Future use  N N/A  N N/ASection [128]: General Options OptionOFF ON[1]Panic 1: keys [1] & [3]   N Disabled  N Enabled [2]Panic 2: keys [4] & [6]   N Disabled  N Enabled [3]Panic 3: keys [7] & [9]   N Disabled  N Enabled[4]Panic 1: silent or audible  N Silent  N Audible[5]Panic 2: silent or audible  N Silent  N Audible[6]Panic 3: silent or fire  N Silent  N Fire[7]Keypad 1 tamper supervision  N Disabled  N Enabled [8]Keypad 2 tamper supervision  N Disabled  N Enabled Section [129]: General OptionsOptionOFF ON[1]PGM2 output activation option  N Steady  N Pulse (flash)[2]PGM2 pulse once every 30 sec. if system armed  N Disabled  N Enabled [3]PGM2 pulse on Arm, twice on Disarm  N Disabled  N Enabled [4]ZX4 & ZX8 zone expansion module supervision  N Disabled  N Enabled [5]Future use   N N/A  N N/A[6]Wireless module low battery supervision  N Disabled  N Enabled [7]4-PGM Output Module supervision (APR3-PGM4)  N Disabled  N Enabled[8]Printer Module supervision (APR3-PRT1)  N Disabled  N Enabled
   Spectra 1759MG     - 13 -     Programming GuideBold = Default Setting* This option cannot be done using a keyswitch. Force arming is not supported by keyswitches.Section [130]: Arming/Disarming OptionsOptionOFF ON[1]One-touch Regular Arming  N Disabled  N Enabled [2]One-touch Stay Arming  N Disabled  N Enabled [3]One-touch Force Arming  N Disabled  N Enabled[4]One-touch bypass programming  N Disabled  N Enabled[5]Restrict arming on battery failure  N Disabled  N Enabled[6]Restrict arming on Tamper failure  N Disabled  N Enabled[7]Bell Squawk on Arm/Disarm with keypad  N Disabled  N Enabled[8]Beep on exit delay  N Disabled   N EnabledSection [131]: Arming/Disarming OptionsOptionOFF ON[1]Report Disarming  N Always   N Only after alarm[2]Regular Arming switches to Force Arming *  N Disabled  N Enabled[3]Bell Squawk on Arm/Disarm with remote control (must be enabled for UL installations)  N Disabled  N Enabled[4]No exit delay when Arming with a remote control  N Disabled  N Enabled[5]No exit delay beeps and no Bell Squawk when Stay Arming  N Disabled  N Enabled[6]Restrict arming on wireless transmitter supervision loss  N Disabled  N Enabled[7]Generate supervision loss if detected on bypassed wireless zone  N Yes  N No[8]Future Use  N N/A  N N/ASection [132]: Zone OptionsOptionOFF ON[1]&[2] N see table  N see table   N see table  N see table[3]Generate tamper if detected on bypassed zone   N Yes  N No[4]EOL (end-of-line) resistors  N No EOL  N Use EOL Resistors [5]Future use  N N/A  N N/A[6]Report zone restore  N On Bell Cut-off  N On Zone Closure[7]&[8] N see table  N see table   N see table  N see tableTamper Recognition Options[1] [2]OFF OFF Disabled (default)OFF ON When disarmed: GENERATES TROUBLE ONLYWhen armed: Follows Zone Alarm Types ON OFF When disarmed: GENERATES SILENT ALARMWhen armed: Follows Zone Alarm TypesON ON When disarmed: GENERATES AUDIBLE ALARMWhen armed: Follows Zone Alarm TypesWireless Transmitter Supervision Options[7] [8]OFF OFF Disabled (default)OFF ON When disarmed: GENERATES TROUBLE ONLYWhen armed: Follows Zone Alarm Types ON OFF When disarmed: GENERATES SILENT ALARMWhen armed: Follows Zone Alarm TypesON ON When disarmed: GENERATES AUDIBLE ALARMWhen armed: Follows Zone Alarm Types
Spectra 1759MG     - 14 -     Programming GuideBold = Default SettingSection [133]: Partition 1 OptionsOptionOFF ON[1]Auto-arm on time  N Disabled  N Enabled[2]Auto-arm on no movement  N Disabled  N Enabled[3]Auto Arming = Regular or Stay  N Regular Arming  N Stay Arming[4]Switch to Stay Arming if no entry delay is opened  N Disabled  N Enabled[5]Stay Arming with Delay Partition 1 (Delay = [070])  N Disabled  N Enabled[6] to [8]Future use  N N/A  N N/ASection [134]: Partition 2 OptionsOptionOFF ON[1]Auto-arm on time  N Disabled  N Enabled[2]Auto-arm on no movement  N Disabled  N Enabled[3]Auto Arming = Regular or Stay  N Regular Arming  N Stay Arming[4]Switch to Stay Arming if no entry delay is opened  N Disabled  N Enabled[5]Stay Arming with Delay Partition 2 (Delay = [070])  N Disabled  N Enabled[6] to [8]Future use  N N/A  N N/ASection [135]: Dialer OptionsOptionOFF ON[1] & [2] N see table  N see table   N see table  N see table[3]Reporting (Dialer)  N Disabled  N Enabled[4]Dialing method  N Pulse Dialing  N Tone (DTMF) Dialing[5]Pulse ratio  N 1:2   N 1:1.5 [6]If armed, activate bell output on Com. Failure   N Disabled  N Enabled[7] & [8]Future use  N N/A  N N/ASection [136]: Dialer OptionsOptionOFF ON[1]Call back WinLoad  N Disabled  N Enabled[2]Automatic event buffer transmission  N Disabled  N Enabled[3]Contact I.D. report codes  N Programmable  N All Codes (automatic)[4]Alternate dial  N Disabled  N Enabled[5]If no dial tone is present  N Continue after 4 sec.  N Hang-up after 16 sec.[6] & [7] N see table  N see table   N see table  N see table[8]Pager Format Transmission Options  N Transmit report code after Pager delay  N Transmit report code immediatelyTelephone Line Monitoring (TLM) Options[1] [2]OFF OFF TLM Disabled (default)OFF ON TLM generates a trouble if armedON OFF TLM generates an audible alarm if armedON ON Silent alarms become audiblePager Reporting Format Dialer Options[6] [7]OFF OFF 1 call to pager or cellular telephone (default)OFF ON 2 calls to pager or cellular telephoneON OFF 3 calls to pager or cellular telephoneON ON 4 calls to pager or cellular telephone
   Spectra 1759MG     - 15 -     Programming GuideBold = Default SettingCommunication SettingsSection [137]: Event Call DirectionOptionOFF ON[1]Call Telephone #1 for Arming/Disarming Report Codes  N Disabled   N Enabled[2]Call Telephone #2 for Arming/Disarming Report Codes  N Disabled  N Enabled[3]Call Telephone #1 for Alarm/Restore Report Codes  N Disabled  N Enabled[4]Call Telephone #2 for Alarm/Restore Report Codes  N Disabled  N Enabled[5]Call Telephone #1 for Tamper/Restore Report Codes  N Disabled  N Enabled[6]Call Telephone #2 for Tamper/Restore Report Codes  N Disabled  N Enabled[7] & [8]Future use  N N/A  N N/ASection [138]: Event Call DirectionOptionOFF ON[1]Call Telephone #1 for Trouble/Restore Report Codes  N Disabled   N Enabled[2]Call Telephone #2 for Trouble/Restore Report Codes  N Disabled  N Enabled[3]Call Telephone #1 for Special Report Codes  N Disabled  N Enabled[4]Call Telephone #2 for Special Report Codes  N Disabled  N Enabled[5] to [8]Future use  N N/A  N N/ASection #[140] ___ / ___TEL1 TEL2REPORTING FORMATS1 = ADEMCO SLOW (1400HZ, 1900HZ, 10BPS)2 = SILENT KNIGHT FAST (1400HZ, 1900HZ, 20BPS)    3 = SESCOA (2300HZ, 1800HZ, 20BPS)    4 = ADEMCO EXPRESS (DTMF 4+2)5 = ADEMCO CONTACT ID (DEFAULT) see option [3] in section [136] on page 146 = PAGER FORMAT If Hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports Hexadecimals. If the pager does not support Hexadecimals, use only the digits 0 to 9.[141] ___/___/___/___ PANEL IDENTIFIER (WINLOAD SOFTWARE)[142] ___/___/___/___ PC PASSWORD (WINLOAD SOFTWARE)[143] ___/___/___/___ PARTITION ACCOUNT NUMBER 1 (For less than 4 digits, use the [FORCE] key to enter blanks.)[144] ___/___/___/___ PARTITION ACCOUNT NUMBER 2 (For less than 4 digits, use the [FORCE] key to enter blanks.)[150] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__PC TELEPHONE NUMBER FOR WINLOAD SOFTWARE (32-digits, if less than 32 press [ENTER] to accept)[151] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__CENTRAL STATION TELEPHONE OR PAGER NUMBER 1 (32-digits, if less than 32 press [ENTER] to accept)[152] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__CENTRAL STATION TELEPHONE OR PAGER NUMBER 2 (32-digits, if less than 32 press [ENTER] to accept)[153] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__BACK UP TELEPHONE NUMBER (32-digits, if less than 32 press [ENTER] to accept)Special Keys for Telephone Numbers[STAY] = * [MEM] = Switch from pulse to tone dialing or vice versa [FORCE] = Delete current digit[BYP] = # [TBL] or [TRBL] = 4-second pause [PG] or [FNC1] = Inserts Blank Space
Spectra 1759MG     - 16 -     Programming GuideReport CodesAdemco Slow, Silent Knight, SESCOA, Ademco Express and Pager Formats: Enter the desired 1- or 2-digit hex-value (0-F or 00-FF). Ademco “Programmable” Format: Enter the desired 2-digit hex values from the “Ademco Report Code List - Programmable” (see Appendix A on page 30). Also Note that entering FF will set the report code to the default Ademco Report Code. Ademco “All Codes” Format: The control panel automatically generates report codes from the “Ademco Report Code List - All Codes” (see Appendix B on page 31).     Arming Report Codes[160]___/___Access Code 01___/___Access Code 02___/___Access Code 03___/___Access Code 04[165]___/___Access Code 21___/___Access Code 22___/___Access Code 23___/___Access Code 24[170]___/___Access Code 41___/___Access Code 42___/___Access Code 43___/___Access Code 44[161]___/___Access Code 05___/___Access Code 06___/___Access Code 07___/___Access Code 08[166]___/___Access Code 25___/___Access Code 26___/___Access Code 27___/___Access Code 28[171]___/___Access Code 45___/___Access Code 46___/___Access Code 47___/___Access Code 48[162]___/___Access Code 09___/___Access Code 10___/___Access Code 11___/___Access Code 12[167]___/___Access Code 29___/___Access Code 30___/___Access Code 31___/___Access Code 32Special Arming Codes[163]___/___Access Code 13___/___Access Code 14___/___Access Code 15___/___Access Code 16[168]___/___Access Code 33___/___Access Code 34___/___Access Code 35___/___Access Code 36[172]___/___Auto-Arming___/___Late to Close___/___No Movement___/___Partial Arming[164]___/___Access Code 17___/___Access Code 18___/___Access Code 19___/___Access Code 20[169]___/___Access Code 37___/___Access Code 38___/___Access Code 39___/___Access Code 40[173]___/___Quick Arming___/___Arming via PC___/___Keyswitch Arming___/___Closing DelinquencyDisarming Report Codes[174]___/___Access Code 01___/___Access Code 02___/___Access Code 03___/___Access Code 04[179]___/___Access Code 21___/___Access Code 22___/___Access Code 23___/___Access Code 24[184]___/___Access Code 41___/___Access Code 42___/___Access Code 43___/___Access Code 44[175]___/___Access Code 05___/___Access Code 06___/___Access Code 07___/___Access Code 08[180]___/___Access Code 25___/___Access Code 26___/___Access Code 27___/___Access Code 28[185]___/___Access Code 45___/___Access Code 46___/___Access Code 47___/___Access Code 48[176]___/___Access Code 09___/___Access Code 10___/___Access Code 11___/___Access Code 12[181]___/___Access Code 29___/___Access Code 30___/___Access Code 31___/___Access Code 32Special Disarming Codes[177]___/___Access Code 13___/___Access Code 14___/___Access Code 15___/___Access Code 16[182]___/___Access Code 33___/___Access Code 34___/___Access Code 35___/___Access Code 36[186]___/___Cancel Auto-Arm___/___Disarming via PC___/___Keyswitch Disarm___/___N/A[178]___/___Access Code 17___/___Access Code 18___/___Access Code 19___/___Access Code 20[183]___/___Access Code 37___/___Access Code 38___/___Access Code 39___/___Access Code 40
   Spectra 1759MG     - 17 -     Programming GuideAlarm Report CodesAlarm Restore Special[187]___/___Zone 01___/___Zone 02___/___Zone 03___/___Zone 04[191]___/___Zone 01___/___Zone 02___/___Zone 03___/___Zone 04[195]___/___Emergency Panic___/___Auxiliary Panic___/___Fire Panic___/___Recent Closing[188]___/___Zone 05___/___Zone 06___/___Zone 07___/___Zone 08[192]___/___Zone 05___/___Zone 06___/___Zone 07___/___Zone 08[196]___/___Zone Shutdown___/___Duress___/___Keypad Lockout___/___N/A[189]___/___Zone 09___/___Zone 10___/___Zone 11___/___Zone 12[193]___/___Zone 09___/___Zone 10___/___Zone 11___/___Zone 12[190]___/___Zone 13___/___Zone 14___/___Zone 15___/___N/A[194]___/___Zone 13___/___Zone 14___/___Zone 15___/___N/ATamper Report Codes [197]Trouble___/___Zone 01___/___Zone 02___/___Zone 03___/___Zone 04[200]___/___Zone 13___/___Zone 14___/___Zone 15___/___N/A[203]___/___Zone 09___/___Zone 10___/___Zone 11___/___Zone 12[198]___/___Zone 05___/___Zone 06___/___Zone 07___/___Zone 08[201]Restore___/___Zone 01___/___Zone 02___/___Zone 03___/___Zone 04[204]___/___Zone 13___/___Zone 14___/___Zone 15___/___N/A[199]___/___Zone 09___/___Zone 10___/___Zone 11___/___Zone 12[202]___/___Zone 05___/___Zone 06___/___Zone 07___/___Zone 08System Trouble Report Codes System Trouble Restore Special[205]___/___N/A___/___AC Failure___/___Battery Failure___/___Auxiliary Supply[208]___/___TLM___/___AC Failure___/___Battery Failure___/___Auxiliary Supply[211]___/___Cold Start (Shutdown)___/___Test Report___/___N/A___/___PC Exit[206]___/___Bell Output Overload___/___Bell Output Disconnect___/___Timer Loss___/___Fire Loop Trouble[209]___/___Bell Output Overload___/___Bell Output Disconnect___/___Timer Loss___/___Fire Loop Trouble[212]___/___Installer In___/___Installer Out___/___N/A___/___N/A[207]___/___Wireless Low Battery___/___Module Fault___/___Printer Fault___/___Fail to Communicate[210]___/___Wireless Low Battery___/___Module Fault___/___Printer Fault___/___Fail to Communicate[213]___/___TX Supervision Loss___/___TX Supervision Restore___/___N/A___/___N/A
Spectra 1759MG     - 18 -     Programming GuideSystem SettingsUser Code OptionsSystem Master Code arms or disarm partitions using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions.Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. Section # Description[280] ___/___:___/___ SYSTEM REAL TIME CLOCK (HH:MM)[281] ___/___/___/___/___/___ INSTALLER CODE, DEFAULT: 0000 / 000000[282] ___/___/___ INSTALLER CODE LOCK, DEFAULT: 000 (147 TO LOCK, 000 TO UNLOCK)[301] ___/___/___/___/___/___ SYSTEM MASTER CODE, DEFAULT: 1234 / 123456Default for all user codes is options [1], [3] and [4] ON.ON = Option EnabledOFF = Option Disabled[1] ON = Partition 1 Access[2] ON = Partition 2 Access[3] ON = Bypass Programming[4] ON = Stay Arming[5] ON = Force Arming[6] ON = Arm Only[7] ON = PGM Activation Only[8] ON = Future UseSection # User Code Options (ON/OFF)Section User Code Options (ON/OFF)[302] Master Code 1 1 2 3 4 5 6 7 8 [325] User Code 025 1 2 3 4 5 6 7 8[303] Master Code 2 1 2 3 4 5 6 7 8 [326] User Code 026 1 2 3 4 5 6 7 8[304] User Code 004 1 2 3 4 5 6 7 8 [327] User Code 027 1 2 3 4 5 6 7 8[305] User Code 005 1 2 3 4 5 6 7 8 [328] User Code 028 1 2 3 4 5 6 7 8[306] User Code 006 1 2 3 4 5 6 7 8 [329] User Code 029 1 2 3 4 5 6 7 8[307] User Code 007 1 2 3 4 5 6 7 8 [330] User Code 030 1 2 3 4 5 6 7 8[308] User Code 008 1 2 3 4 5 6 7 8 [331] User Code 031 1 2 3 4 5 6 7 8[309] User Code 009 1 2 3 4 5 6 7 8 [332] User Code 032 1 2 3 4 5 6 7 8[310] User Code 010 1 2 3 4 5 6 7 8 [333] User Code 033 1 2 3 4 5 6 7 8[311] User Code 011 1 2 3 4 5 6 7 8 [334] User Code 034 1 2 3 4 5 6 7 8[312] User Code 012 1 2 3 4 5 6 7 8 [335] User Code 035 1 2 3 4 5 6 7 8[313] User Code 013 1 2 3 4 5 6 7 8 [336] User Code 036 1 2 3 4 5 6 7 8[314] User Code 014 1 2 3 4 5 6 7 8 [337] User Code 037 1 2 3 4 5 6 7 8[315] User Code 015 1 2 3 4 5 6 7 8 [338] User Code 038 1 2 3 4 5 6 7 8[316] User Code 016 1 2 3 4 5 6 7 8 [339] User Code 039 1 2 3 4 5 6 7 8[317] User Code 017 1 2 3 4 5 6 7 8 [340] User Code 040 1 2 3 4 5 6 7 8[318] User Code 018 1 2 3 4 5 6 7 8 [341] User Code 041 1 2 3 4 5 6 7 8[319] User Code 019 1 2 3 4 5 6 7 8 [342] User Code 042 1 2 3 4 5 6 7 8[320] User Code 020 1 2 3 4 5 6 7 8 [343] User Code 043 1 2 3 4 5 6 7 8[321] User Code 021 1 2 3 4 5 6 7 8 [344] User Code 044 1 2 3 4 5 6 7 8[322] User Code 022 1 2 3 4 5 6 7 8 [345] User Code 045 1 2 3 4 5 6 7 8[323] User Code 023 1 2 3 4 5 6 7 8 [346] User Code 046 1 2 3 4 5 6 7 8[324] User Code 024 1 2 3 4 5 6 7 8 [347] User Code 047 1 2 3 4 5 6 7 8[348] User Code 048 1 2 3 4 5 6 7 8
   Spectra 1759MG     - 19 -     Programming GuideReprogram All ModulesParadox Memory Key (PMC-3)Download to DESTINATION Control Panel1) Remove AC and battery power from the control panel.2) Insert the Memory Key onto the serial connector labelled KEY on the Spectra control panel to which you wish to download the contents of the memory key to.3) Re-apply AC and battery power. 4) Enter installer programming mode, enter section [900], then press [ENTER] to acknowledge. 5) When the keypad emits a “confirmation beep”, remove the Memory Key.6) Enter section [750] to reprogram the modules with the information downloaded from the Paradox Memory Key.Copy to Memory Key from SOURCE Control Panel1) Remove AC and battery power from the control panel.2) Insert Memory Key onto the serial connector labelled KEY on the Spectra control panel that you want to copy. Make sure the write protect jumper of the Memory Key is on.3) Re-apply AC and battery power.4) Enter installer programming mode, enter section [902], then press [ENTER] to acknowledge.5) When the keypad emits a Confirmation Beep, remove the Memory Key. Remove the Memory Key’s jumper if you do not wish to accidentally overwrite its contents.[750]After removing an expansion module from the communication bus, the control panel keeps the module’s programmed sections in memory. Therefore, if you add or replace a module you can re-program the module with the settings saved in the control panel. To do so, enter section [750] and press [ENTER]. The keypads will beep twice every second until the procedure is completed.[900]DOWNLOAD FROM PARADOX MEMORY KEY TO DESTINATION CONTROL PANEL.[902]COPY TO MEMORY KEY FROM SOURCE CONTROL PANEL.Jumper ON = Read from and/or write to memory keyParadox Memory Key PMC-3Jumper OFF = Write protected (read from memory key only)Insert Paradox Memory Key onto the ‘MEMORY KEY’ connector.Partial view of Spectra 1759MG control panel
Spectra 1759MG     - 20 -     Programming Guide4-PGM Output Modules V2.0Due to the APR3-PGM4’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PGM4 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PGM4 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.Bold = Default SettingPGM ProgrammingEach PGM Deactivation event can be used as another activation event if their respective PGM timer (see sections [501] to [504]) is programmed with a value other than 000. The APR3-PGM4 uses the same PGM events as the Spectra control panel, please refer to Programmable Outputs on page 9.Section # Decimal Value (000-255) Description Default Value [501] ___/___/___ (000 = follow deactivation event) PGM1 TIMER 5 sec.[502] ___/___/___ (000 = follow deactivation event) PGM2 TIMER 5 sec.[503] ___/___/___ (000 = follow deactivation event) PGM3 TIMER 5 sec.[504] ___/___/___ (000 = follow deactivation event) PGM4 TIMER 5 sec.Section # Event Group # Sub-Group # Partition #[505] PGM1 Activation Event ___/___ ___/___ ___/___[506] PGM1 Deactivation Event ___/___ ___/___ ___/___[507] PGM2 Activation Event ___/___ ___/___ ___/___[508] PGM2 Deactivation Event ___/___ ___/___ ___/___[509] PGM3 Activation Event ___/___ ___/___ ___/___[510] PGM3 Deactivation Event ___/___ ___/___ ___/___[511] PGM4 Activation Event ___/___ ___/___ ___/___[512] PGM4 Deactivation Event ___/___ ___/___ ___/___Section [500]: General OptionsOptionOFF ON[1] PGM1 Time Base Selection  N Seconds  N Minutes[2] PGM2 Time Base Selection  N Seconds  N Minutes[3] PGM3 Time Base Selection  N Seconds  N Minutes[4] PGM4 Time Base Selection  N Seconds  N Minutes[5] to [8] Future use  N N/A  N N/A
   Spectra 1759MG     - 21 -     Programming GuidePrinter Module V2.0Due to the APR3-PRT1’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PRT1 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PRT1 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.Bold = Default SettingSection [550]: General OptionsOptionOFF ON[1] Assigned to Partition 1  N Disabled  N Enabled[2] Assigned to Partition 2  N Disabled  N Enabled[3] PGM normal state  N Normally Open (N.O.)  N Normally Closed (N.C.)[4] Print Arming and disarming events  N Disabled  N Automatically[5] Print Alarm and Alarm Restore events  N Disabled  N Automatically[6] Print Tamper and Tamper Restore events  N Disabled  N Automatically[7] Print Trouble and Trouble Restore events  N Disabled  N Automatically[8] Print Special events  N Disabled  N AutomaticallySection [551]: Automatic Zone Status PrintingOptionOFF ON[1] Print status of Zone 1  N Disabled  N Automatically[2] Print status of Zone 2  N Disabled  N Automatically[3] Print status of Zone 3  N Disabled  N Automatically[4] Print status of Zone 4  N Disabled  N Automatically[5] Print status of Zone 5  N Disabled  N Automatically[6] Print status of Zone 6  N Disabled  N Automatically[7] Print status of Zone 7  N Disabled  N Automatically[8] Print status of Zone 8  N Disabled  N AutomaticallySection [552]: Automatic Zone Status PrintingOptionOFF ON[1] Print status of Zone 9  N Disabled  N Automatically[2] Print status of Zone 10  N Disabled  N Automatically[3] Print status of Zone 11  N Disabled  N Automatically[4] Print status of Zone 12  N Disabled  N Automatically[5] Print status of Zone 13  N Disabled  N Automatically[6] Print status of Zone 14  N Disabled  N Automatically[7] Print status of Zone 15  N Disabled  N Automatically[8] N/A  N N/A  N N/A
Spectra 1759MG     - 22 -     Programming GuideBold = Default SettingPGM ProgrammingThe PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to Programmable Outputs on page 9.Section #   Decimal Value (000-255) Description Default Value [554] ___/___/___ seconds (000 = follow deactivation event) PGM1 TIMER 5sSection # Event Group # Sub-Group # Partition #[555] PGM1 Activation Event ___/___ ___/___ ___/___[556] PGM1 Deactivation Event ___/___ ___/___ ___/___Clock ProgrammingFor example, to enter the date March 26, 2004 you would enter 2004 (year), 03 (month), and 26 (day).Section # Value [557] Year ___/___/___/___   Month ___/___   Day ___/___Section [553]: Serial and Parallel Port Setup OptionsOptionOFF ON[1]Serial port  N Disabled  N Enabled[2]&[3] N see table  N see table   N see table  N see table[4]Parallel port  N Disabled  N Enabled[5]Off-line status ignored (parallel port only)  N Disabled  N Enabled [6]Paper empty status ignored (parallel port only)  N Disabled  N Enabled[7]Printer fault status ignored (parallel port only)  N Disabled  N Enabled[8]Printer busy status ignored (parallel port only)  N Disabled  N EnabledBaud Rate Settings[2] [3] APR-PRT1 APR3-PRT1OFF OFF 1200 baud (default) 2400 baud (default)ON OFF 2400 baud 9600 baudOFF ON 9600 baud 19200 baudON ON 19200 baud 57600 baud
   Spectra 1759MG     - 23 -     Programming GuideVoice-assisted Arm/Disarm Bus Module V2.0Due to InTouch’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), DGP-848 or DGP-NE96 control panels. When connected to the bus, InTouch automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one InTouch can be connected to each Spectra control panel. APR3-ADM2 can also be programmed using the WinLoad Software. Refer to the WinLoad Online Help for more information.Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.Section # Decimal Value (000-255) Description Default Value [575] ___/___/___ rings (000 = disabled) NUMBER OF RINGS 8 rings[576] ___/___/___ seconds (010-255, 000 = disabled) ANSWERING MACHINE OVERRIDE 000 [577] ___/___/___ seconds/minutes (000 = disabled) PGM TIMER 005 Bold = Default SettingSection [578]: General OptionsOptionOFF ON[1]Stand-alone Code length  N 6-digits  N 4-digits[2]Partitioned system  N Disabled  N Enabled[3]PGM output  N Disabled  N Enabled[4]PGM time in  N Seconds  N Minutes[5] to [8]Future use  N N/A   N N/A
Spectra 1759MG     - 24 -     Programming GuideWireless FeaturesDo not cut, bend or alter 1759MG’s antennae and ensure that electrical wires do not cross over the antennae, as this may affect signal reception.Zone Assignment The serial number can be located on the inside of the transmitter or you can use the Serial Number Display feature (see page 24). Also, refer to Zone Recognition Table on page 6. Section #         Serial #[601] ___/___/___/___/___/___= EXPANSION INPUT 1[602] ___/___/___/___/___/___= EXPANSION INPUT 2[603] ___/___/___/___/___/___= EXPANSION INPUT 3[604] ___/___/___/___/___/___= EXPANSION INPUT 4[605] ___/___/___/___/___/___= EXPANSION INPUT 5[606] ___/___/___/___/___/___= EXPANSION INPUT 6[607] ___/___/___/___/___/___= EXPANSION INPUT 7[608] ___/___/___/___/___/___= EXPANSION INPUT 8Bold = Default SettingSerial Number DisplaySection # Description [630] Press the anti-tamper switch of the Magellan Wireless Transmitter. The keypad will emit a confirmation beep. On LED keypads, press the [ENTER] key to view the digits one at a time. On LCD keypads, the first 3 digits of the serial number will appear. Press the [ENTER] key 3 times to view the next 3 digits. Continue activating the desired transmitters or press [CLEAR] to exit. Signal Strength DisplaySection # DescriptionAfter entering the desired section, activate the Magellan Wireless Transmitter by opening/closing the zone or by pressing the anti-tamper switch. Always ignore the first reading as it won’t be accurate. An average reading of 3 or higher is acceptable. [631] Display Signal Strength of Expansion Input 1 - Section [601][632] Display Signal Strength of Expansion Input 2 - Section [602][633] Display Signal Strength of Expansion Input 3 - Section [603][634] Display Signal Strength of Expansion Input 4 - Section [604][635] Display Signal Strength of Expansion Input 5 - Section [605][636] Display Signal Strength of Expansion Input 6 - Section [606][637] Display Signal Strength of Expansion Input 7 - Section [607][638] Display Signal Strength of Expansion Input 8 - Section [608] Section [610]: General OptionsOptionOFF ON[1] Wireless transmitter check-in supervision  N Disabled  N Enabled[2] Check-in supervision interval  N 24h  N 80min[3] to [7] Future use  N N/A  N N/A[8] Tamper Supervision  N Disabled   N Enabled
   Spectra 1759MG     - 25 -     Programming GuideRemote Control User AssignmentSection # Decimal Value Description Default Value [701] ___/___/___(001-048 = user #) remote control #1 - section [731]*000[702] ___/___/___(001-048 = user #) remote control #2 - section [732]*000[703] ___/___/___(001-048 = user #) remote control #3 - section [733]*000[704] ___/___/___(001-048 = user #) remote control #4 - section [734]*000[705] ___/___/___(001-048 = user #) remote control #5 - section [735]*000[706] ___/___/___(001-048 = user #) remote control #6 - section [736]*000[707] ___/___/___(001-048 = user #) remote control #7 - section [737]*000[708] ___/___/___(001-048 = user #) remote control #8 - section [738]*000* refer to Remote Control Assignment on page 26.Button OptionsPlease note that the User Code assigned to the remote control (sections [701] to [708]) must have the same User Options and Button Options enabled. For example, if you enable the Force Arming button option you must enable the appropriate Force Arming user option. Also, if you enable any of the Panic button options, you must enable the Panic options in the control panel.Remote Control Button ProgrammingRC# Section RC ButtonsDefault: ( 1  5  0  0  0  0  0  0 )1 [711]   _____/_____/_____/_____/______/_____/_____/______        2 [712]   _____/_____/_____/_____/______/_____/_____/______        3 [713]   _____/_____/_____/_____/______/_____/_____/______        4 [714]   _____/_____/_____/_____/______/_____/_____/______        5 [715]   _____/_____/_____/_____/______/_____/_____/______        6 [716]   _____/_____/_____/_____/______/_____/_____/______        7 [717]   _____/_____/_____/_____/______/_____/_____/______        8 [718]   _____/_____/_____/_____/______/_____/_____/______        Button Options TableEmpty Slot [FORCE] - Button disabled1 - Regular arming2 - Stay arming3 - Instant arming4 - Force arming5 - Disarm6 - Disarm when no alarm7 - Regular arm and disarm8 - Panic 19 - Panic 2A - Panic 3B - PGM Activation (Event Group #7, see PGM Programming)C - PGM Activation (Event Group #8, see PGM Programming)D - PGM Activation (Event Group #9, see PGM Programming)MG-REM1++ + +++ + +++++++ + +++ + +++++++ + +++ + += These button combinations are not available with the MG-REM1or MG-RAC1 remote controls and cannot be programmed.
Spectra 1759MG     - 26 -     Programming GuideRemote Control Assignment Enter the appropriate section and press any button on the remote control twice to assign the remote control. If you hear a rejection beep, an error has occurred or the remote control has already been assigned. To delete a remote control, enter the desired section and then press the [FORCE] button.Section #[731] REMOTE CONTROL #1[732] REMOTE CONTROL #2[733] REMOTE CONTROL #3[734] REMOTE CONTROL #4[735] REMOTE CONTROL #5[736] REMOTE CONTROL #6[737] REMOTE CONTROL #7[738] REMOTE CONTROL #8
   Spectra 1759MG     - 27 -     Programming GuideZone Expansion Bus ModulesOnly one SPC/APR3-ZX4 or one SPC/APR3-ZX8 can be connected to each Spectra control panel. The following sections are for SPC-ZX4 version 1.0, APR3-ZX4 version 1.0, SPC-ZX8 version 1.0 and APR3-ZX8 version 2.0.Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96.Bold = Default SettingPGM Programming (SPC-ZX8 and APR3-ZX8 Only)The PGM will only activate or deactivate 100mS after the selected event occurs. The PGM Deactivation event can be used as another activation event if the PGM Timer (section [655]) is programmed with a value other than 000. The system will ignore the PGM if it has been programmed to follow the Global PGM (option [3] in section [650]). Only PGM events from the table below can be used.Section # Decimal Value (000-255) Description Default Value [655] ___/___/___  seconds (000 = follow deactivation event) PGM1 TIMER 5 sec.Section # Event Group # Sub-Group # Partition #[656] PGM1 Activation Event ___/___ ___/___ ___/___[657] PGM1 Deactivation Event ___/___ ___/___ ___/___Section [650]: OptionsOptionOFF ON[1]EOL (end-of-line) resistors for hardwire modules  N No EOL  N Use EOL Resistors [2]Zone Expansion Module tamper recognition  N Disabled  N Z1 becomes tamper input [3]PGM1 on SPC/APR3-ZX8 follows Global PGM programmed in sections [124] & [125]  N Disabled  N Enabled[4] to [8]Future Use  N N/A  N N/ASection [651]: Zone AssignmentOption See Zone Recognition Table on page 6. OFF ON[1] Input Z1  =Expansion Input 1   N Disabled  N Enabled[2] Input Z2  =Expansion Input 2   N Disabled  N Enabled[3] Input Z3  =Expansion Input 3   N Disabled  N Enabled[4] Input Z4  =Expansion Input 4   N Disabled  N Enabled[5] Input Z5 (SPC/APR3-ZX8 only) =Expansion Input 5   N Disabled  N Enabled[6] Input Z6 (SPC/APR3-ZX8 only) =Expansion Input 6  N Disabled  N Enabled[7] Input Z7 (SPC/APR3-ZX8 only) =Expansion Input 7  N Disabled  N Enabled[8] Input Z8 (SPC/APR3-ZX8 only) =Expansion Input 8  N Disabled  N EnabledEvent Group # Sub-Group # Partition #For SPC-ZX8:60 = Hardwire Zone Opened61 = Hardwire Zone Closed62 = Hardwire Tamper Opened63 = Hardwire Tamper ClosedFor APR3-ZX8:60 = Hardwire Zone/Hardwire Tamper Opened61 = Hardwire Zone/Hardwire Tamper Closed01 = Expansion Input 1 - Section [651] - [1]02 = Expansion Input 2 - Section [651] - [2]03 = Expansion Input 3 - Section [651] - [3]04 = Expansion Input 4 - Section [651] - [4]05 = Expansion Input 5 - Section [651] - [5]06 = Expansion Input 6 - Section [651] - [6]07 = Expansion Input 7 - Section [651] - [7]08 = Expansion Input 8 - Section [651] - [8]99 = Any zone expansion bus module inputNot used; enter 00
Spectra 1759MG     - 28 -     Programming GuideUser OperationPartitioningThe Spectra system is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an office/warehouse building. If the system is not partitioned, all User Codes and features will be recognized as belonging to Partition 1.Programming Access CodesUser Access Codes are personal identification numbers that allow users to enter certain programming modes, arm or disarm the alarm system as well as activate or deactivate PGMs. Spectra security systems support the following:System Master Code can arm or disarm any partition using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions.Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. 45 User Access Codes (including 1 Duress code) How does a partitioned system work?• Users can only arm or disarm their assigned partitions.• Only zones assigned to Partition 1 will arm or disarm when Partition 1 is armed or disarmed.• Only zones assigned to Partition 2 will arm or disarm when Partition 2 is armed or disarmed.• Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms.• Some of the system’s features can be programmed separately for each partition.How Do I Program Access Codes?1) Press [ENTER]2) Key in the [SYSTEM MASTER CODE] or [MASTER CODE] 3) Key in 3-digit [SECTION] (see User Code Table)4) Key in new 4- or 6-digit [ACCESS CODE][ENTER] flashes. Return to step 3How Do I Delete Access Codes?1) Repeat steps 1 to 3 (see above)2) Press the [FORCE] key once for each digit in the access code (4 or 6 times) until the keypad emits a Confirmation Beep.User Code TableSection User Codes[001] User Code 001 = System Master Code[002] User Code 002 = Master Code 1[003] User Code 003 = Master Code 2[004] TO [047] User Code 004 to User Code 047[048] User Code 048 or Duress Code
   Spectra 1759MG     - 29 -     Programming GuideProgramming Chime ZonesThis feature allows users to program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent beep tone (BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be Chime Programmed separately. Keypad chimes must be re-programmed if the system suffers a total power loss (16-zone LED and LCD Keypads only). 10-Zone LED KeypadPress and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and hold the [1] key to enable chiming on zone 1. If, after pressing and holding a key, the keypad emits a confirma-tion beep, this means the chime feature has been enabled for that zone. If the keypad emits a Rejection Beep, this means the Chime feature has been disabled for the corresponding zone.16-Zone LED KeypadPress and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s). When the corresponding LED is on, the zone is chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [ENTER]. LCD KeypadPress and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s) or use the arrow keys to scroll through the zones. When the appropriate zone is displayed, press the [FNC1] key. When the desired zones are chimed, press [ENTER].Keypad MutingPress and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is pressed or when the keypad emits a Rejection or Confirmation Beep. All other beep functions are disabled. Keypad Backlight (1686H and 1686V Only)The illumination level behind the keys can be modified to suit the user’s needs. There are four backlight levels. The [MEM] key is used to set the desired level. Each consecutive push of the [MEM] key will increase the backlight level until the maximum level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated. To change the backlight level:Quick Function KeysInstaller Test Mode[ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]The Installer Test Mode allows you to perform walk tests where the bell/siren will squawk once to indicate an open zone and twice to indicate a closed zone. To enter this mode, press [ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]. The keypad will emit a Confirmation Beep. To disable this mode, press the [TBL] or [TRBL] key again. The keypad will emit a Rejection Beep.Test Report[ENTER] + [INSTALLER/MASTER CODE] + [MEM] Sends the Test Report report code programmed in section [211] to the central station. Call WinLoad Software [ENTER] + [INSTALLER/MASTER CODE] + [BYP]This feature is used to establish communication between the control panel and a computer using the WinLoad Software. After entering this mode, the control panel will dial the telephone number programmed in section [150].Cancel Communication[ENTER] + [INSTALLER/MASTER CODE] + [STAY]Cancels all communication until the next reportable event. If the Master Code was used, only communication with WinLoad would be cancelled.Answer WinLoad Software [ENTER] + [INSTALLER/MASTER CODE] + [FORCE]Forces the control panel to pick-up an incoming telephone call.How do I Modify the Backlight?1) Press and hold the [MEM] key for 3 seconds2) The [MEM] key will illuminate3) Press the [MEM] key to set the desired backlight level4) Press [CLEAR] or [ENTER] to exit
Spectra 1759MG     - 30 -     Programming GuideAppendix A - Ademco CID Report Code List (Prog.)If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog. Value) into sections [160] to [213] to program the desired report codes. To enter a 0 value press the [FORCE] key.CID# Reporting  Prog.Code Value CID# Reporting  Prog.Code Value CID# Reporting  Prog.Code ValueMEDICAL ALARMS - 100 203 Gate Valve Sensor 2E 401 O/C by User 5B100 Medical Alarm 01 204 Low Water Level 2F 402 Group O/C 5C101 Pendant Transmitter 02 205 Pump Activated 30 403 Automatic O/C 5D102 Fail to Report In 03 206 Pump Failure 31 404 Late to O/C 5EFIRE ALARMS - 110 SYSTEM TROUBLES - 300 & 310 405 Deferred 5F110 Fire Alarm 04 300 System Trouble 32 406 Cancel 60111 Smoke 05 301 AC Loss 33 407 Remote Arm/Disarm 61112 Combustion 06 302 Low System Battery 34 408 Quick Arm 62113 Water Flow 07 303 RAM Checksum Bad 35 409 Keyswitch O/C 63114 Heat 08 304 ROM Checksum Bad 36 REMOTE ACCESS - 410115 Pull Station 09 305 System Reset 37 411 Callback Request Made 64116 Duct 0A 306 Panel Program Changed 38 412 Success - Download Access 65117 Flame 0B 307 Self-Test Failure 39 413 Unsuccessful Access 66118 Near Alarm 0C 308 System Shutdown 3A 414 System Shutdown 67PANIC ALARMS - 120 309 Battery Test Failure 3B 415 Dialer Shutdown 68120 Panic Alarm 0D 310 Ground Fault 3C ACCESS CONTROL - 420121 Duress 0E SOUNDER/RELAY TROUBLES - 320 421 Access Denied 69122 Silent 0F 320 Sounder Relay 3D 422 Access Report By User 6A123 Audible 10 321 Bell 1 3E SOUNDER RELAY DISABLES - 520BURGLAR ALARMS - 130 322 Bell 2 3F 520 Sounder/Relay Disabled 6B130 Burglary 11 323 Alarm Relay 40 521 Bell 1 Disable 6C131 Perimeter 12 324 Trouble Relay 41 522 Bell 2 Disable 6D132 Interior 13 325 Reversing 42 523 Alarm Relay Disable 6E133 24-Hour 14SYSTEM PERIPHERAL TROUBLES - 330 & 340524 Trouble Relay Disable 6F134 Entry/Exit 15 330 System Peripheral 43 525 Reversing Relay Disable 70135 Day/Night 16 331 Polling Loop Open 44 COMMUNICATION DISABLES - 550 & 560136 Outdoor 17 332 Polling Loop Short 45 551 Dialer Disabled 71137 Tamper 18 333 Exp. Module Failure 46 552 Radio xmitter Disabled 72138 Near Alarm 19 334 Repeater Failure 47 BYPASSES - 570GENERAL ALARMS - 140 335 Local Printer Paper Out 48 570 Zone Bypass 73140 General Alarm 1A 336 Local Printer Failure 49 571 Fire Bypass 74141 Polling Loop Open 1B COMMUNICATION TROUBLES - 350 & 360 572 24-Hour Zone Bypass 75142 Polling Loop Short 1C 350 Communication  4A 573 Burg. Bypass 76143 Expansion Module Failure 1D 351 Telco Fault 1 4B 574 Group Bypass 77144 Sensor Tamper 1E 352 Telco Fault 2 4C TEST/MISC. - 600145 Expansion Module Tamper 1F 353 Long Range Radio 4D 601 Manual Trigger Test 7824-HOUR NON-BURGLARY - 150 & 160 354 Fail to Communicate 4E 602 Periodic Test Report 79150 24-Hour Non-Burglary 20 355 Loss of Radio Supervision 4F 603 Periodic RF Xmission 7A151 Gas Detected 21 356 Loss of Central Polling 50 604 Fire Test 7B152 Refrigeration 22 PROTECTION LOOP TROUBLES - 370 605 Status Report to Follow 7C153 Loss of Heat 23 370 Protection Loop 51 606 Listen-in to Follow 7D154 Water Leakage 24 371 Protection Loop Open 52 607 Walk Test Mode 7E155 Foil Break 25 372 Protection Loop short 53 621 Event Log Reset 7F156 Day Trouble 26 373 Fire Trouble 54 622 Event Log 50% Full 80157 Low Bottled Gas Level 27 SENSOR TROUBLES - 380 623 Event Log 90% Full 81158 High Temp 28 380 Sensor Trouble 55 624 Event Log Overflow 82159 Low Temp 29 381 Loss of Super. -RF 56 625 Time/Date Reset 83161 Loss of Air Flow 2A 382 Loss of Super. - RPM 57 626 Time/Date Inaccurate 84FIRE SUPERVISORY - 200 & 210 383 Sensor Tamper 58 627 Program Mode Entry 85200 Fire Supervisory 2B 384 RF xmtr. Low Battery 59 628 Program Mode Exit 86201 Low Water Pressure 2C OPEN/CLOSE - 400 631 Exception Schedule Change 87202 Low CO2 2D 400 Open/Close 5A 654 System Inactivity 88
   Spectra 1759MG     - 31 -     Programming GuideAppendix B - Ademco CID Report Code List (All Codes)System Event Default Contact ID Report Code when option [3] is on in section [136]System Event Default Contact ID Report Code when option [3] is on in section [136]Arming with Master Code (##) 3 4A1 - Close by user Auxiliary supply trouble 1 3AA - System troubleArming with User Code (##) 3 4A1 - Close by user Bell output current limit 1 321 - Bell 1Arming with Keyswitch (##) 3 4A9 - Keyswitch Close Bell absent 1 321 - Bell 1Auto Arming 3 4A3 - Automatic Close Clock lost 1 626 - Time/Date inaccurateArm with PC software 3 4A7 - Remote arm/disarm Fire loop trouble 1 373 - Fire troubleLate To Close 3 4A4 - Late to Close Wireless Transmitter Low Battery1 384 - RF xmtr. low batteryNo Movement  3 4A4 - Late to Close Wireless Transmitter Supervision Loss1 381 - Loss of super. - RFPartial arming 1 574 - Group bypass Module fault 1 333 - Expansion module failureQuick arming  3 408 - Quick arm Printer fault 1 336 - Local printer failureFail to communicate with central station1 354 - Fail to communicateDisarm with Master Code (##) 1 4A1 - Open by user Wireless Transmitter Low Battery1 384 - RF xmtr. low batteryDisarm with User Code (##) 1 4A1 - Open by user TLM trouble restore 3 351 - Telco 1 fault restoreDisarm with Keyswitch (##) 1 4A9 - Keyswitch Open AC Failure restore 3 3A1 - AC loss restoreDisarm after alarm with Master Code (##)1 4A1 - Open by user Battery Failure restore 3 3A9 - Battery test restoreDisarm after alarm with User Code (##)1 4A1 - Open by user Auxiliary supply trouble restore 3 3AA - System trouble restoreDisarm after alarm with Keyswitch (##)1 4A9 - Keyswitch Open Bell output current limit restore 3 321 - Bell 1 restoreBell absent restore 3 321 - Bell 1 restoreAuto Arming Cancellation 1 4A5 - Deferred Open/Close Clock programmed 3 626 - Time/Date ResetDisarm with PC software 1 4A7 - Remote arm/disarm Fire loop trouble restore 3 373 - Fire trouble restoreDisarm after an alarm with PC software1 4A7 - Remote arm/disarm Wireless Transmitter Low Battery3 384 - RF xmtr. low batteryWireless Transmitter Supervision Loss3 381 - Loss of super. - RFZone Bypassed (##) 1 57A - Zone bypass Module fault restore 3 333 - Expansion module failure            restoreZone alarm (##) 1 13A - Burglary Alarm Printer fault restore 3 336 - Local printer failure restoreFire alarm (##) 1 11A - Fire alarm Fail to communicate with central station3 354 - Fail to communicate restoreZone alarm restore (##) 3 13A - Burglary Alarm RestoreFire alarm restore (##) 3 11A - Fire alarm Restore Cold Start 1 3A8 - System shutdownTest Report engaged 1 6A2 - Periodic test reportPanic 1 - Emergency  1 12A - Panic alarm PC software communication finished1 412 - Successful - download accessPanic 2 - Medical  1 1AA - Medical alarm Installer on site 1 627 - Program mode EntryPanic 3 - Fire  1 115 - Pull Station Installer programming finished 1 628 - Program mode ExitDelinquency 1 654 - InactivityRecent closing 3 4AA - Open/CloseGlobal zone shutdown 1 574 - Group bypassDuress alarm 1 121 - DuressZone shutdown (##) 1 57A - Zone bypassZone tampered (##) 1 144 - Sensor tamperZone tamper restore (##) 3 144 - Sensor tamper restoreAC Failure 1 3A1 - AC lossBattery Failure 1 3A9 - Battery test failure
Spectra 1759MG     - 32 -     Programming GuideBus Module ConnectionsPrinter Module (APR3-PRT1)Remove AC power and battery before adding APR3-PRT1 to the system. Do not connect any modules more than 76m (250ft) from the control panel. Only one Printer Module can be connected per Spectra control panel.A Green “Locate” LED: Remains illuminated during power upB Red “Watchdog” LED: Flashes to indicate proper operation. If there is a communication failure, the red LED will flash ON for one second and OFF for one second.C Red “TX” LED: Flashes when the Printer Module is transmitting data through the serial port only.D 25-pin Parallel Port: Connect the Printer Module’s 25-pin parallel port to any dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns.E 9-Pin Serial Port: Connect the Printer Module’s 9-Pin serial port to a dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns.F 9-Pin Serial Port: Connect the Printer Module’s 9-Pin serial port to a computer’s COM port to view the control panel’s events on the computer’s monitor. The events displayed on the monitor can then be printed through the printer connected to the computer.Spectra 1759MGControl PanelCommunication BusRX LED reserved for future usePress the “PRINT TEST” switch to perform a print testNot UsedABDEFCConnecting the PGM Output
   Spectra 1759MG     - 33 -     Programming Guide4-PGM Output Module (APR3-PGM4) 4-zone expansion Bus Module (SPC-ZX4 and APR3-ZX4) Red “Watchdog” LED:Status: flashes once per second to indicate proper operation.Flash 1 second on and 1 second off: The module is experiencing a communicationfailure with the control panel. External Power Supply(Recommended: ParadoxPSW817 1.75A SwitchingPower Supply)To Spectra 1759MG control panelNot UsedAny device such as a garage door opener, light or sirenCommunication BusRemove AC and battery from the control panel before adding the 4-PGM Output Module to the system. Do not connect the APR3-PGM4 more than 76m (250ft) from the control panel. Only one APR3-PGM4 can be connected per Spectra control panel.Not UsedRed “WDG” LED:Status = Flashes to indicate proper operation.Flash 1 sec. on & 1 sec. off = Trouble and/or communication failure.Connect the detection devices to the module's input terminals exactly as shown in the Spectra 1759MG Reference & Installation Manual.Not UsedSpectra 1759MGcontrol panel Communication BusRemove AC and battery power from the control panel before connecting the module to the communication bus. Do not connect the APR3-ZX4 or SPC-ZX4 more than 76m (250ft) from the control panel. Only one APR3-ZX4 or one SPC-ZX4 can be connected per Spectra control panel.Input terminal Z1 can be used as an anti-tamper switch input Option [2]: Section [650]Connecting the Anti-Tamper Switch
Spectra 1759MG     - 34 -     Programming GuideVoice-assisted Arm/Disarm Bus Module (APR3-ADM2)Green "PULSE"LED: Monitors the dialer. The LED will illuminate when the dialer is in use. When the dialer is not being used, the LED will remain off.Red “WATCHDOG” LED:Flashes once every second = normal.Flashes 1 second on & 1 second off = trouble and/or communication failure.Communication BusGround clampCold water pipe groundingHousehold telephoneRefer to Inset 1To Spectra 1759MG control panelSpectra 1759MG DialerNot UsedInset 1: Connecting the APR3-ADM2 PGM OutputPartial view of the APR3-ADM2External Power Supply(Recommended: Paradox PSW817 1.75A Switching Power Supply)Any device such as a garage door opener, light or sirenRemove AC and battery power from the control panel before adding the APR3-ADM2 module to the system. Do not connect the APR3-ADM2 more than 76m (250ft) from the control panel. Only one APR3-ADM2 can be connected per Spectra control panel.
   Spectra 1759MG     - 35 -     Programming Guide8-Zone Expansion Bus Modules (SPC-ZX8 and APR3-ZX8) Red “WDG” LED:Flash once every sec. = normal. Flash 1 sec. on & 1 sec. off = Trouble and/or communication failure.Not UsedInset 2Not UsedInset 1Refer to the Spectra 1759MG Reference & Installation Manual about connecting devices to the Expansion Input Terminals.Communication Bus Spectra 1759MG control panelInset 1: Connecting the PGM output Inset 2: Anti-Tamper Switch ConnectionInput terminal Z1 can be used as an anti-tamper switch input.Option [2]: Section [650]Remove AC power and battery before adding a module to the system. Do not connect the APR3-ZX8 or SPC-ZX8  more than 76m (250ft) from the control panel. Only one SPC-ZX8 or APR3-ZX8 can be connected per Spectra control panel.
Spectra 1759MG     - 36 -     Programming GuideHardware ConnectionsSingle Zone InputsConnecting Fire Circuits, Keyswitches and PGMsProgram the PGM with the “[PG]/[FNC1] Key was pressed” Activation Event so that the smoke detectors can be reset by pressing the [PG] or [FNC1] key. See Event Group # 5 on page 9.All 4-wire smoke detectors must be connected using the daisy chain configuration.Programming a Wireless Fire ZoneFire zones cannot be assigned to expansion zones. As a result, when installing a wireless smoke detector, the corresponding zone must be programmed as follows: 1) Enter [5] in the Zone Definition to define it as a 24Hr Burglary Alarm (see page 7).2) Disable [4] and enable [5] in Zone Options to set the zone’s alarm type to a pulsed Audible Alarm (see page 7).3) Disable [1] and [2] in Zone Options to disable the zone’s Auto Zone Shutdown and Bypass Enabled features (see page 7).Fire Circuits4-Wire InstallationControl Panel TerminalsKeyswitch PGM4) Change the zone’s report code from a Burglary Report Code (Prog. Value 11) to a Fire Report Code (Prog. Value 04). See Appendix A on page 30. If using Ademco Contact I.D., set the Contact ID Options from All Codes to Programmable (section [136] option [3] = OFF) and then enter the report code manually (see page 14).
   Spectra 1759MG     - 37 -     Programming GuideAlarm Relay and PGM ConnectionsConnecting More Than Two KeypadsIf there are more than 2 keypads connected to the control panel and at least one keypad zone is being used, connect as shown and program as described in the Spectra 1759MG Reference & Installation Manual.When a 1641 LCD keypad is connected to Spectra, the Keypad Zone Sending option (Option [2] key [1]) determines whether the status of the keypad zone will be transmitted to the control panel. Refer to the 1641 Installer’s Guide for more information. The Keypad Zone Sending option of the 1641 keypad must be enabled during the following conditions:• If you are using both keypad zones and at least one is from a 1641 keypad.• If you are using the keypad zones of other types of keypads, such as a 1686H 10-zone LED keypad, and the keypad zone definition of the 1641 keypad (keypad zone 1 or keypad zone 2; Option [2] key [3]) matches that of another connected keypad.AC Power & Backup Battery ConnectionsTransformer Requirements Table  Transformer: Amseco XP-1620 16VAC 20VA * Recommended: 16VAC 40VAUL: Basler BE156240CAA007Spectra DC PowerSupply rated at:1.2A 1.5AAuxiliary Supply can provide a maximum of:typ: 600mAmax: 700mAtyp: 600mAmax: 700mAUL installations: typ. 200mAAcceptable Battery Charge Currents (section [127] option [5])350mA 350mA / 700mA* Not verified by ULPGMs  When the device connected to a PGM is powered by:AUX+ terminal =  must not exceed 700mAExternal power supply = PGM1 cannot exceed 150mAPGM2 cannot exceed 1AIf power supply's current limit is less than that of the PGM it is connected to, then the current consumption cannot exceed the power supply's current limit.PGM2 can be used as a strobe output. AUX+External power supplyAlarm Relay (5A) can be programmed to follow the BELL output or the Global PGMExternal Power SupplyAny device such as a strobe light or sirenDo not place a jumper across the zone and “BLK” input terminals of the keypads that are not using their keypad zones.A Door Contact or any other detection device. 1686H(Using keypad zone) 1686H(Not using keypad zone)1641 LCD Keypad(Not using keypad zone)Be sure to enable option [1] (”Keypad Zone Sending”) of option [2] (”Options”) in the 1641’s LCD Programming Mode.Partial view of Spectra 1759MG control panelUL Warning: A 12Vdc / 7Ah battery is required to comply with UL fire requirements.Caution:Disconnect battery before replacing the fuse.Rechargeable BatteryUL/ULC - 12Vdc / 4Ah or 7AhWarning:Improper connection of the transformer may result in damage to the system.
Spectra 1759MG     - 38 -     Programming GuideSpectra 1759MG PCB LayoutFor UL and C-UL warnings, refer to the UL and C-UL Warnings section at the back of the Spectra 1759MG Reference & Installation Manual.To connect the 5A Alarm Relay and the PGMs, refer to Alarm Relay and PGM Connections on page 37. To connect AC power, refer to AC Power & Backup Battery Connections on page 37.Refer to Single Zone Inputs on page 36Refer to AC Power & Backup Battery Connections on page 37.For the keypad’s zone, EOL and tamper configurations, refer to page 5.Warning: Do not connect keypads more than 76m (250ft) from the control panel.A Door Contact or any other detection device can be connected to the Keypad  Zone.AUX Power Refer to transformer requirements on page 37 for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output.Spectra KeypadsThe maximum number of keypads per installation is dependent on the auxiliary output, which cannot exceed 700mA.To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals.To metallic enclosureGround clampAWG#14 single conductor solid copper wireCold water pipe groundingThe "BELL" output will shutdown if the current exceeds 3A.Communication BusWarning:Disconnect telephone line before servicing.Four pin connector can be used for quick installation of a Spectra keypad or Expansion Module.Warning:Do not cut, bend or alter the antennae and ensure that electrical wires do not cross over the antennae, as this may affect signal reception.Paradox Memory Key (PMC-3)Reset JumperAntennae"RX" LED:Flashes quickly whenreceiving signals from wireless devices."STATUS" LED:Flash once every second = normalFlashes ON 1 second and OFF 1 second = troubleAlways ON = panel is using phone lineFast flash 4 seconds after power up = installer lock enabled Warning:This equipment must be installed and maintained by qualified service personnel only.
WarrantyParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. © 2002-2005 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply. Spectra, Digiplex and Magellan are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Fri-day from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.ca. 780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444                                       Fax: (450) 491-2313www.paradox.caPRINTED IN CANADA - 01/2005                               1759MG-EP05