Panasonic Mobile Communications 611849144431A RRH4x40-PCS KS24829L11 User Manual

Panasonic Mobile Communications Co., Ltd. RRH4x40-PCS KS24829L11

User Manual

  PCS RRH List11  Installation Guide  Issue: 1.0.0    1/17 PMC CONFIDENTIAL       PCS RRH List11 Installation Guide  Product Name : RRH4x40-PCS KS24829L11 Model Number : 849144431       Issue: 1.0.0 Date; July 21, 2011
  PCS RRH List11  Installation Guide  Issue: 1.0.0    2/17 PMC CONFIDENTIAL  Revison History Issue No.  Description  Date 1.0.0  First edition  July 08, 2011
  PCS RRH List11  Installation Guide  Issue: 1.0.0    3/17 PMC CONFIDENTIAL  Table of Contents Revison History .....................................................................................................................................  2 Table of Contents  ...................................................................................................................................  3 1 INTRODUCTION  .............................................................................................................................  4 1.1 System Overview ......................................................................................................................  4 1.2 Equipment Outline  ....................................................................................................................  5 1.3 Structural Outline  ......................................................................................................................  6 1.4 Specification  .............................................................................................................................  7 1.4.1 System Specification  .......................................................................................................... 7  1.4.2 Optical Module Specification .............................................................................................. 8 1.4.3 PCS Band Remote Radio Heads Specification ................................................................... 9 2 Installing the RRH .........................................................................................................................  10 2.1 Appearance  ............................................................................................................................  10 2.2 User Interface  .........................................................................................................................  11 2.3 Cable List  ...............................................................................................................................  13 2.4 Power cable installing procedure ............................................................................................ 14 2.5 Powering On the RRH ............................................................................................................  16 2.6 System Start-Up Procedure .................................................................................................... 16 3 FCC WARING  ...............................................................................................................................  17
  PCS RRH List11  Installation Guide  Issue: 1.0.0    4/17 PMC CONFIDENTIAL  1 IN TRODUCTION  1.1 S ystem Overview  PCS R RH List11 co nnect w ith BBU  w hich made  by  Alcatel -Lucent. An d, this RR H is transiver  system which is support LTE and CDMA fuction in 1900MHz frequency band range.      List11 consist from 2pcs of List10 whch is connected by optical cabel. CPRI Interface of one PCS RRH List10 connect to BBU (LTE)   Another one CPRI interface connect to BBU (CDMA)  BBU(LTE)BBU(CDMA)PCS RRHTX25MHzList10PCS RRHTX25MHzList10CPRIPCS RRH List11   Figure 1-1 System Overview
  PCS RRH List11  Installation Guide  Issue: 1.0.0    5/17 PMC CONFIDENTIAL  1.2 Equipment Outline   Figure 1-2 Equipment Outline  ①  Execute transmit and receive BBU and UL/DL Digital Signal by optical interface ②  Enable to  maintain RRH with O CI (On site  Confi guration Inte rface) an d Pe rsonal Computer.   ③  Enable to  use Alarm-interface detect function(one is moni toring. another is detection for 2pcs List10)     ④  AISG suppl y an d contr ol po wer function w hich is connec ted to towe r-top e quipment from           RRH ⑤  This system support    DC -48 Vpower input ⑥  Execute sever al fun ctions (S tatus-Control/Tranciver-Control/Mesurement/Failure -Control…) based on control message of BBU. ⑦  Enable to download Software(Control Software, DSP Firmware、FPGA Data) as            Remotely.   BBU (LTE)BBU (CDMA) PCS RRHTX25MHzList10PCS RRHTX25MHzList10CPRICPRICPRITower-topEquipmentAISGDC - 48VOCI( Ether)Alams MonitorAlamsIdentification connectorDC - 48VPrimaryPrimarySecondarySecondaryPCS RRH List11
  PCS RRH List11  Installation Guide  Issue: 1.0.0    6/17 PMC CONFIDENTIAL  1.3 S tructural Outline  【Structure Outline】 ①  1system(List11) consist from 2pcs of RRH(List10) ②  Thermal method is naturally air‐cooled engine(Cooling Fan Less) ③  Enable to l oad next ca ble (P ower Cable/Optical C able/AISG Ca ble/ALM Ca ble/AUX Cable) from bottom side of the RRH. And, enable to load Antenna Cable from Upper side of the system ④  Equipped M6 electrical ground in lower side of the system   ⑤  In order to monitoring output power of transmi ssion point, Implement 2pcs (List10) of electrical terminal. ⑥  There are installing “Water proof cap” and “Dust Proof Cap” as external connector   ⑦  There are LED in bottom side of the RRH which can monitoring system status. ⑧  All function can control by control box which box can be open   ⑨  Enable to install “ibolt” to upper side of the system
  PCS RRH List11  Installation Guide  Issue: 1.0.0    7/17 PMC CONFIDENTIAL  1.4 S pecification  1.4.1 S ystem Specification  No Item  Content   Remark  1 Input Power   -48V (-37V~-57V)  2 Powe r Consumption   340.7W x2   3 W eight  Less than 20kg   4  Water resistant level  IP65 as specified by IEC529 IP66 as specified by IEC60529 NEMA type4  5 T emperature range   -40~+55℃  6 Humi dity range  5~95%  7 Dime nsion  W:330 mm D:176 mm H:530 mm (  not include connectors  )  8  Thermal Type    naturally air cooled engine     9  Setting Location   Outside
  PCS RRH List11  Installation Guide  Issue: 1.0.0    8/17 PMC CONFIDENTIAL  1.4.2  Optical Module Specification   No Item  Condition/etc   Remark  1  Optical Center Length  <Primary port> DL:1550 nm、UL:1310 nm <Secondary port> Mix mode:1550 nm/1310 nm RRH1:1550 nm, RRH2:1310 nm or RRHq:1310 nm, RRH2:1550 nm  2 Bit Rate <Primary port> CDMA:0.6144 Gbps~1.2288 Gbps LTE  :1.2288 Gbps~6.1440 Gbps <Secondary port> 2.4576 Gbps~6.144 Gbps  3  Transmission Distance <Primary port> Maximum 20 km <Secondary port> Maximum 50m
  PCS RRH List11  Installation Guide  Issue: 1.0.0    9/17 PMC CONFIDENTIAL  1.4.3  PCS Band Remote Radio Heads Specification  No Item    Type  Remark 1 Supp ort Technologies  LTE/CDMA   2  RF Output Power    40W/Branch×2×2  List11 co nsist fr om 2pcs  of List10 3  Downlink RF Frequency    1930 MHz –1995 MHz   4  Uplink RF Frequency      1850 MHz –1915 MHz   5 Numb er of Carrier   LTE :2Carrier×2 CDMA:8Carrier×2 List11 co nsist fr om 2pcs  of List10
  PCS RRH List11  Installation Guide  Issue: 1.0.0    10/17 PMC CONFIDENTIAL  2  Installing the RRH  2.1 Appe arance       Figure 2-1 Appearance of the RRH with connector covers (There are 2-M8 female threads on opposite side) 4-M8 female threads for Equipment mounting 4-M6 female threads for Ground Lugs (There are 2-M6 female threads on opposite id )
  PCS RRH List11  Installation Guide  Issue: 1.0.0    11/17 PMC CONFIDENTIAL  2.2 U ser Interface   Figure 2-2 User Interface (Top view)   Figure 2-3 User interface (Bottom view)   Figure 2-4 Detail of Service Access Ports    (1) (2) (8)(3) (4) (5)  (6)(7)(10) (11)(12) (13)(9)(14)(15)  (16) (17) (19) (18)
  PCS RRH List11  Installation Guide  Issue: 1.0.0    12/17 PMC CONFIDENTIAL  Table 2-1 Connectors, LED, Reset button etc.                  No.  Location  Connector Name  Connector Type and Comment 1  On the Top  TX/RX 1  7/16 DIN F 2  TX/RX 2  7/16 DIN F 3  On the Bottom  AUX RX1  N-type F 4  AUX RX2  N-type F 5  CPRI PRI  SFP Connector  Tyco Electronics 1888247-1 SFP Shield Cage  Tyco Electronics 2007198-1 Flange Connector  SFP with Waterproof Radial Part# R299.988.00 6  CPRI SEC  SFP Connector  Tyco Electronics 1888247-1 SFP Shield Cage  Tyco Electronics 2007198-1 Flange Connector  SFP with Waterproof Radial Part# R299.988.00 7  Status LED  Indicate green or red or yellow 8  AISG  Female 8-pin circular connector, per IEC 60130-9 9 External User Alarms 1-4 Female 8-pin circular connector, per IEC 60130-9 10  DC -48V IN  Water-proof entry connector can be mounted 11 V entilator  12  TX MON 1  SMA F 13  TX MON 2  SMA F 14  Service access door  15  Service access Port  on the Bo ttom of  the RRH Serial Interface  IEEE1394 16 OCI (Ethernet) RJ45 17 Reset button - 18  Domestic Port 1   19  Sensor for service access door
  PCS RRH List11  Installation Guide  Issue: 1.0.0    13/17 PMC CONFIDENTIAL  2.3 Cable List  1. Power cable; # 14 AWG strand wires are recommended. From # 14 to # 8 AWG strand wires are available.
  PCS RRH List11  Installation Guide  Issue: 1.0.0    14/17 PMC CONFIDENTIAL  2.4  Power cable installing procedure  1. Preparation of Power cable 1.1. Remove the jacket of power cable by 30 mm. 1.2. Strip the jacket from an inner cable by 8 mm.    Figure 2-5 Preparation of Power cable   Do not damage the power cable when cutting around jacket.  2. Loose the screws of cabling cavities cover. 3. Open the cover 4. Mount entry connector (water-proof type) on the DC-48V-IN port.    Figure 2-6 Preparation of the equipment Screws of cabling cavity Open the cover Mount entry connector on the DC-48V-IN port Warning
  PCS RRH List11  Installation Guide  Issue: 1.0.0    15/17 PMC CONFIDENTIAL  5. Put power cable inside from the hole of entry connector   6. Loose cable fixing screws of terminal block 7. Insert each cable to th e suitable hole of terminal, according to the instruction of the rear of the cover 8. Fix the terminal screws 10 in-lbs (1.13 Nm)   Figure 2-7 Fixing Power cables  9. Fix the cable by entry connector 10. Close the cabling cavities cover 11. Fix the screws of cabling cavity’s cover xx Nm    Figure 2-8 Fixing Power cable and cover Fix Power cable by entry connector Close the coverCable fixing screws Put Power cable inside The hole of entry connecter Cable fixing screwsTerminal block -48RTN.IDC SUPPLY-48RTN.IDC SUPPLY -48VRTN IN
  PCS RRH List11  Installation Guide  Issue: 1.0.0    16/17 PMC CONFIDENTIAL  2.5  Powering On the RRH  1. Turn off the breaker of the power supply and connect the power supply cable. 2. Connect the other cables before turn on the breaker. 3. After start up the BBU, please turn on the power supply to RRH. 4. Please confirm the RRH start state with Status LED.   2.6 S tatus LED  LED Display States No. S tate  LED Display 1  No Power Supplied  Off 2  Initial Power Supply  Solid Red 3  External Power Supply Failure Flash Red 4 Sof tware Download  Flash Yellow 5 No nrecoverable Critical Failure Solid Red 6 Reco verable Critical  Failure Flasu Red 7  Slave CPRI Ling Failure Solid Yellow 8 No n-Critical Nonrecoverable Failure Solid Red 9 No n-Critical Recoverable Failure Flash Red 10  External Antenna Failure Flash Red 11  Normal Operation  Solid Green 12 S tandby  Flash Green
  PCS RRH List11  Installation Guide  Issue: 1.0.0    17/17 PMC CONFIDENTIAL  3 FCC WARING  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Properly shielded an d grounded cabl es and conn ectors must b e used  for connection to  host computers and / or peripherals in order to meet FCC emission limits.  Data transmission is always initiated by software, which is th e passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. Inother words, this device automatically discontinue transmission in case of either absence of information to transmit or operational failure.           Frequecncy Tolerance: 11 ppb            This transmitter must not be co-located or operated in conjunction with any other antenna         or transmitter.

Navigation menu