PROXIPI BFBC Badge Fixe User Manual

PROXIPI INC Badge Fixe

User Manual

  PROXIPI USER MANUAL [EN] V2016-08  Page 1 sur 21                   PROXIPI user manual PROXIPI Equipment
Page 2 sur 21   Copyright          Copyright  2018 – PROXIPI S.A.S. Révision 16.08, English version. All  rights reserved. Reproduction in any way whatsoever  of  all  or  part of this document without the written consent  of PROXIPI S.A.S is prohibited. The name, brand and logos are protected by Copyright laws. PROXIPI® is a registered trade mark; the brand  name and logo are protected. PROXIPI technology is patent pending (FR2977358 B1, WO2013000888 A1). Other brand names and logos belong to their respective owners. The information in this manual is, to our knowledge, accurate.  As a result of continual improvements through research and development, this manual may be modified without notice and without PROXIPI S.A.S. being obliged to update this version of the manual. PROXIPI S.A.S. has produced this manual with the single aim of providing the user with simple and accurate information. PROXIPI S.A.S. cannot be held accountable for any incorrect interpretation made while reading this manual. In spite of our efforts to produce a manual which is error-free, it may nevertheless contain a few unintentional technical inaccuracies. If in doubt, please contact PROXIPI S.A.S. for additional information.  PROXIPI S.A.S. 50 rue Ettore Bugatti F – 76800 Saint-Etienne-du-Rouvray Tel.: +33 235 664 734 Fax: +33 972 214 861 Web site: www.proxipi.com  E-mail: contact@proxipi.com
PROXIPI user manual [EN] V2016-08   Page 3 sur 21  Table of contents TABLE OF CONTENTS ............................................................................................................... 3 WARNINGS ............................................................................................................................. 4 Aim of the manual .............................................................................................................. 4 Warranty, limits of liability ................................................................................................... 4 Recommendations ............................................................................................................. 5 General safety .................................................................................................................... 5 Usage limits ........................................................................................................................ 7 Destruction of the equipment .............................................................................................. 7 Improvements and modifications ........................................................................................ 7 Reception-Storage ............................................................................................................. 7 Spare parts ......................................................................................................................... 7 Rating plate ........................................................................................................................ 7 Declarations of conformity .................................................................................................. 8 DESCRIPTION OF THE PROXIPI SYSTEM ................................................................................... 9 Aim of the Proxipi® system ................................................................................................ 9 Components ....................................................................................................................... 9 Features ........................................................................................................................... 10 Usage principle ................................................................................................................. 10 PROXIPI in action ............................................................................................................ 11 The advantages of PROXIPI® .......................................................................................... 11 PROXIPI EQUIPMENT ........................................................................................................... 12 Standard truck equipment ................................................................................................ 12 Pedestrian Badge ............................................................................................................. 13 The Fixed Zone Badge ..................................................................................................... 16 Machine Badge ................................................................................................................ 16 TECHNICAL SPECIFICATIONS .................................................................................................. 18 Standard truck equipment ................................................................................................ 18 Pedestrian Badge ............................................................................................................. 19 The Fixed Zone Badge ..................................................................................................... 20 Machine Badge ................................................................................................................ 21
  Page 4 sur 21  Warnings AIM OF THE MANUAL This  manual  is  aimed  at  any  person  wishing  to  use  the Machine-pedestrian collision prevention system referred to as PROXIPI in this document. This manual provides information on:  The safety rules associated with PROXIPI.  The use of PROXIPI.  The technical specifications of PROXIPI. Recommendations relating to the declaration of conformity of the European Community, to the warranty and application of the system are also included in this manual. PROXIPI S.A.S. has produced this manual with the aim of providing simple information as accurately as possible. As such PROXIPI S.A.S. cannot assume any responsibility for any incorrect interpretation. The  owner  of  the  manual  is  responsible  for  keeping  this manual throughout the life of the PROXIPI system and must pass it on any purchaser to whom it is sold. Any information or change relating to this manual must be sent to the local representative of PROXIPI S.A.S. WARRANTY, LIMITS OF LIABILITY Warranty The PROXIPI system must be used in accordance with its approved purpose and under normal conditions; PROXIPI SAS accepts no responsibility for any usage not compliant with its approved purpose and for the consequences of this incorrect usage. Delivery of goods is at the responsibility of the seller when this is carried out by a transport company duly authorized by PROXIPI S.A.S. Otherwise, it is at the buyer's responsibility. The  seller  guarantees  the  supply  against  any  defect  in design, material, manufacture or construction affecting the PROXIPI system. To enact the warranty, contact the seller to show them the proof of purchase sent. In the event of a failure, the seller will advise you. New  equipment  (excluding  consumables),  including  new accessories  sold  in  the  box  with  the  equipment,  are guaranteed by PROXIPI SAS, parts and labour (excluding travel), against any manufacturing fault for a period of twelve (12) months from the date the equipment was sold to the customer after presentation of proof showing the purchase date of the equipment. Equipment subject to repair or standard replacement during the warranty period mentioned above are guaranteed (parts and labour) until the latest of these two dates: expiry of the twelve (12) month warranty period mentioned above or three (3) months from the date work was carried out by PROXIPI SAS.  Any defective equipment under warranty will be replaced or   repaired free of charge at the discretion of PROXIPI SAS, excluding  the  repair  of  any  other  loss,  it  being  specified however that the works required to implement the warranty shall take place in the workshop; return expenses (transport and insurance) of the equipment to the address which will be given to them by PROXIPI SAS after-sales service whose telephone number is shown on the delivery note to be borne by  the  customer.  Subject  to  mandatory  legal  provisions, PROXIPI SAS takes on no warranty, explicit or implicit, other than that expressly provided for in the present text and, in no case whatsoever shall PROXIPI SAS meet any intangible and/or  indirect  damages  (such  as,  in  particular,  loss  of orders, loss of profits) or any other financial or commercial loss whether under the warranty or otherwise. Accepting an item of equipment under the warranty requires on the one hand a legible and unmodified proof of purchase showing the name and address of the seller, the date and location  of  the  purchase  and  the  type  of  equipment  and serial  number  being  affixed  to  the  equipment  and on  the other  hand  that  the  information  appearing  on  the identification label of the equipment is legible and that this label or any other seal has not been altered. The warranty applies under normal conditions of use. PROXIPI S.A.S. may, at its discretion, repair the equipment using new or reconditioned parts or replace the equipment with new. The system will, in any event, be returned in good working order. During this work, PROXIPI SAS reserves the right to apply, if need be, any technical modifications to the equipment  they  think  fit  insofar  as  these  changes  do  not prejudice its original purpose. The defective items, subject to replacement during a repair operation under warranty become the property of PROXIPI SAS. The  period  for  which  the  equipment  is  under  repair  and immobilised during the warranty period cannot result in an extension  of  the  warranty  period  unless  mandatory  legal provisions to the contrary apply. The application of the warranty is dependant on all sums due on the equipment at the time work is requested being paid in full. Excluded in particular are defects, failures or malfunctions due  in  particular,  but  not  limited  to,  non-compliance  with installation  and  usage  recommendations,  to  a  cause external to the equipment (shock, lightning, fire, vandalism, malevolence,  water  damage  of  any  kind,  contacts  with various  liquids  or  any  harmful  agent,  unsuitable  electric voltage, etc.), to modifications to the equipment carried out without  the  written consent  of  PROXIPI  SAS,  to  a  defect further to damage (negligence, breakage, sabotage), to poor environmental conditions around the equipment (particularly those  related  to  temperature  and  hygrometric  conditions, effects of variations in electric voltages, noise spikes from the  power  network  or  from  earth)  or  to  a  repair  or  work (opening or attempt to open the equipment) or maintenance carried out by individuals not approved by PROXIPI SAS, damage  following  failures  in  packaging  and/or unsatisfactory packaging of equipment returned to PROXIPI SAS, normal wear of the equipment along with wear of the accessories, problems of communication associated with an unfavourable environment, a transmission fault as well as the  provision  of  new  software  versions.  PROXIPI  SAS cannot  be  held  accountable  for  system  malfunctions
PROXIPI user manual [EN] V2016-08   Page 5 sur 21  associated  with  electromagnetic  interference  on  the operating site This  warranty  is  applied  in  accordance  with  the  seller's general terms and condition of sale. Limits of liability As required by the applicable laws, it is expressly agreed that the warranty  stipulated for this  equipment is  the only express, implied or legal warranty that the seller grants on the  equipment  sold  and,  unless  provided  for otherwise  in writing, the buyer shall desist from any action that the buyer (or  their  employees,  affiliated  companies,  successors  or dealers)  could  take  against  the  seller,  their  employees, affiliated companies, successors or dealers arising from the equipment sold; these include, but are not limited to, actions with regard to personal accidents, damages to assets other than  those  covered  by  the  contract,  losses  or  indirect  or intangible  damages  in  particular  loss  of  use  or  profit  etc. Likewise, and still as required by the applicable laws, the buyer undertakes  to indemnify the seller their employees, affiliated  companies,  successors  or  dealers  against  any claim,  complaint,  request,  legal  decision,  litigation  and responsibilities of all kinds as well as all costs or expenses, sustained  or  declared  against  the  seller  regarding  the equipment sold. RECOMMENDATIONS This manual contains information and warnings which the user must heed in order to ensure their safety and to keep the  product  operating  safely.  The  recommendations  are described in the following sections. GENERAL SAFETY Symbols used  Meaning: The  reader's  attention  is  drawn  to  this information regarding the use of the product. There is no risk to the user if this point is not heeded;  it  generally  provides  additional information.   Meaning:  Danger  in  general:  beware  of  various possible  risks.  This  symbol  appears  in various sections of this manual. This  device  meets  the  requirements  of  the  standards mentioned in section EC declaration of conformity on page 8. Manufactured and tested in compliance with EC and FCC standards  relating  to  electrical  equipment,  the  modules installed  on  the  machines  jointly  with  the  machine manufacturers and modules designed for pedestrians, once installed, are perfectly safe from a technical point of view. To maintain these conditions and guarantee safe use, the user must comply with the indications and symbols contained in this manual. When it is no longer safe to use them, the modules installed on the machines and pedestrian modules must be taken out of  service  and  steps  taken  to  ensure  they  are  not  used accidentally.  Safe  use  is  no  longer  guaranteed  in  the following cases: The  assembly  (magnetic  frame,  operator  dashboard, electronic  unit)  installed  on  a  machine  is  visibly damaged.  This  machine  may  no  longer  be  used  in  a zone protected by pedestrian modules.  The module designed for use by pedestrians is visibly damaged.  This  module  may  no  longer  be  used  by  a pedestrian and must be returned to the local retailer or to PROXIPI SAS for repair.  After prolonged storage under unfavourable conditions.  After serious damage sustained during transportation or after damage has occurred on the modules installed on machines and/or those intended for use by pedestrians. General safety guidelines General safety with regard to vulnerable adults, children and electricity The badge must never be left within reach of persons with intellectual  disabilities  and/or  young  children;  certain removable parts may be accidentally ingested. General safety with regard to electricity Once connected, the power supply to PROXIPI equipment installed on a machine must never be modified. Access to this  equipment  is  reserved  to  qualified  personnel  only, particularly  with  regard  to  maintenance.  In  addition,  all possible  precautions must be taken  to  avoid any incident associated with electrical hazards. The modules designed for use by pedestrians must only be connected to the  chargers specified in the manufacturer's catalogue. The use of any other charger may be dangerous and would invalidate the warranty. The mains voltage must comply with that shown on the rating plate of the charger. Call an agent who has been duly authorised/approved by PROXIPI SAS for any problems commissioning the system (magnetic frame, operator's dashboard, etc.) installed on a machine. Do not try to dismantle the PROXIPI badge. You alone  are  responsible  for  the  use  of  the  badge  and  the consequences arising from this. The badge must under no circumstances  be  charged  in  an  area  which  is  damp  or potentially  damp.  The  badge  must  not  be  used  in  damp areas and must be protected against spray from water or other liquids. If sprayed by water, contact the local agent for advice and/or repair. Safety with regard to radio waves To  comply  with  ISED  SPR-002 –  Supplementary Procedure  for  Assessing  Compliance  with  RSS-102 Nerve  Stimulation  Exposure  Limits  )  –  for  general population / uncontrolled exposure, the frame antenna of  the Kit  FLEX  Magnetic Frame  must  be  installed to provide a separation distance of at least 20 cm from all persons during normal operation.   The  badges  comply  with  international  requirements regarding exposure to radio waves. Each  badge  is  a  transmitter/receiver  designed  to  comply with the radio wave exposure limits agreed internationally. These  limits  have  been  determined  by  the  independent scientific organisation ICNIRP and include a safety margin intended to provide protection for all, whatever their age or state of health. As PROXIPI badges offer a whole range of functions, they may be used  in other  positions, i.e.  worn on  the body as described in this manual. The maximum transmission power of a PROXIPI device is less than 2A/m at 50 cm at LF and less than 10mW at UHF; the transmission power of the badge when used is typically
PROXIPI user manual [EN] V2016-08     Page 6 sur 21  lower.  This  is  due  to  the  automatic  changes  of  power undertaken by the badge in order to only use the minimum level required to communicate with the overall system. Additional information may be obtained on the sites of the Institut  National  de  Recherche  et  de  Sécurité  (French National  Research  and  Safety  Institute)  and  the International  Commission  on  Non-Ionizing  Radiation Protection in the following documents:  Electrical fields. Magnetic fields. Electromagnetic waves (FR)1  Lignes  directrices  pour  l'établissement  de  limites d'exposition  aux  champs  électriques  et  magnétiques variables dans le temps (FR)2  ICNIRP Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (EN)3 This  model  has  thus  been  tested  in  compliance  with requirements regarding exposure to radio frequencies when worn on the body. When in use, the PROXIPI badge must be kept in a carrying accessory on the body which does not contain  metal  (e.g.  safety  jacket)  and  which  keeps  it  a minimum  of  1,5  cm  from  the  body.  The  use  of  other accessories  does  not  guarantee  compliance  with  the requirements regarding exposure to radio frequencies. Safety with regard to magnetic fields With a  view  to  limiting  exposure  to electromagnetic fields (radio frequencies, RF) for individuals who wish to limit their exposure  to  these  fields,  the  World  Health  Organisation (WHO) proposes the following precautions. If individuals are worried, they can choose to limit their own RF exposure by moving the badge away from their head or body. General user safety As  with  any  device,  this  equipment  may  suffer  an electrical,  electronic  or  mechanical  failure.  The manufacturer  cannot  be  held  accountable  for  any accidents or risks following such a failure even during the warranty period. The  configuration,  dismantling,  maintenance  and troubleshooting  procedures  are  exclusively  reserved  to individuals  who  have  been  previously  trained  and  duly authorised by PROXIPI SAS. General safety regarding hazardous areas It  is  essential  not  to  bring  a  badge  near  ATEX-classified areas in compliance with the warning signs in place. Usage restrictions on radio devices must be observed in chemical plants,  fuel  depots  and  any  location  where  operations involving explosives are in progress. General mechanical safety The PROXIPI assembly has been installed on the machine in  compliance  with  the  recommendations  specified  in  the Installation  manual.  It  should  be  remembered  that  any modification  to  the  structure  of  a  machine  receiving  the equipment  is  subject  to  certain  rules,  directives  and standards. Thus it is strictly forbidden to drill the operator safety  cage  or  cab  receiving  the  magnetic  frame.  It  is strongly recommended to obtain authorisation to modify the equipment from the manufacturer or their representative.                                                             1   http://www.inrs.fr/accueil/produits/mediatheque/doc/publications.html?refINRS=ED%20785 2   http://www.inrs.fr/accueil/produits/mediatheque/doc/publications.html?refISafety regarding general electronic equipment To prevent any risk of demagnetisation, it is recommended not to leave electronic equipment near the PROXIPI system installed on the machine for extended periods of time. Safety regarding electronic medical equipment The PROXIPI system has been designed in compliance with French  and  European  standards.  The  transmission  levels measured during tests make it compatible with wearing a pacemaker  or  insulin  pump.  Nevertheless,  as  it  is  not possible  to check  all  electronic medical products worn by users,  we  do  not  recommend  the  product  be  used  by individuals fitted with these. It is generally recommended to those fitted with implants to keep the badge at lest 30 cm away. If  need  be, a  doctor  or the manufacturers of  these devices will provide the necessary information.  General conditions for use in total safety  Before being used for the first time, the PROXIPI system must have been inspected by a qualified individual and the badges put on charge. After the initial charge, carry out  an  operation  test  as  defined  in  the  section  on charging the badge.  Carefully read the instructions set out in this manual.  Follow the safety instructions provided in the workplace, the general standards for the prevention of accidents as well as local safety standards.  Maintain all safety devices in their original condition.  Do not modify parts of the machine such as attachment systems, drilled holes, etc. to adapt it other devices. PROXIPI  S.A.S.  is  not  liable  for  the  consequences  if warnings  are  ignored.  It  is  recommended  to  contact PROXIPI  SAS  or  approved  distributors  directly  regarding any modifications.  Prohibitions and obligations regarding predictable behaviour The instructions detailed in this manual, if strictly adhered to by  users,  will  enable  the  PROXIPI  system  to  be  put  into service effectively and safely. This is defined as: "Correct usage".  Any  operation  carried  out  at  the  user's  initiative  which departs from the instructions given is defined as: "Incorrect usage". Precautions in the event of failure When  it  is  suspected  that  the  assembly  installed  on  a machine and/or a pedestrian badge is no longer safe (for example due to damage sustained during transport or use), it must be taken out of service and tagged out. Steps must be taken to ensure it cannot be used accidentally. NRS=PR%2047 3  http://www.icnirp.de/documents/emfgdl.pdf
PROXIPI user manual [EN] V2016-08   Page 7 sur 21  USAGE LIMITS The equipment has been designed for use under industrial conditions  both  under  cover  and  out  in  the  open.  It  is designed  exclusively  for  the  safety  of  pedestrians  in  an industrial  environment.  Furthermore,  depending  on  the configuration ordered, some functions or options may not be enabled. The products sold comply with EC standards. As such, they comply with EMC standards and are designed to operate in an  environment  which  complies  with  the  standards described  in  the  user  manual.  Where  there  is magnetic/electromagnetic  contamination  on  the  site, whether permanent or occasional, the quality of the signals from the products may be disturbed. PROXIPI SAS cannot under  any  circumstances  be  held  accountable  for  these disturbances  and  the  consequences  of  the  reduction  in efficiency of the signals. DESTRUCTION OF THE EQUIPMENT When  the  equipment  becomes  obsolete,  the  assembly installed on the machine and/or pedestrian badges must be destroyed  through  specialist  channels.  Local  legal regulations  take  precedence  over  this  text  and  must  be scrupulously complied with. To  facilitate  recycling  of  the  packaging,  it  is  essential  to comply with the sorting rules put in place locally for this type of waste. The equipment on the other hand may be returned directly to the following address: PROXIPI SAS Innovapôle 76 50 rue Ettore Bugatti F - 76800 Saint Etienne du Rouvray Removal of the equipment from machines is at the exclusive costs  of  the  end  customer  or  their  representative.  The manufacturer  will  take  responsibility  for  decontaminating and recycling all components, the products being designed in accordance with an ecological approach and as such fully recyclable.  In  compliance  with  directive  WEEE 2002/96/EC,  the  PROXIPI  system  may  be constructed from electronic components which are harmful to the environment. All owners are asked to contact the producer or distributor in order to ascertain the procedure to be followed for recycling the equipment. The producer shall not under any circumstances be responsible for recycling  a  PROXIPI  system  which  has  not followed the defined procedure.  The Pedestrian and Intra badges contain one or more Li-ion type batteries needed to power the  electronic  circuit  of  the  badge.  The battery(ies) must be removed prior to the badge being  destroyed  and  disposed  of  in  a  used battery collection centre. IMPROVEMENTS AND MODIFICATIONS Improvements and modifications may be made at any time and  without  prior  notice  to  the  product  described  in  this publication without PROXIPI SAS being in any case obliged to  update  the  content  of  this  manual  and/or  the corresponding equipment. RECEPTION-STORAGE Reception When  the  package  is  received,  check  for  any  external damage and, if necessary, report any damages or shortages to the carrier in the usual way by registered letter, fax or e-mail within 24 hours after delivery. Temporary storage If any or all of the PROXIPI components need to be stored before  use,  they must  be  kept  in their  original  packaging which has been carefully closed if opened. Storage must be in a clean and dry location at a moderate temperature (-20°C to  +40°C),  so  as  to  avoid  the  electronic  components deteriorating.  The  storage  area  must  be  away  machine movement areas; otherwise the badge will be activated each time a machine is detected. Prolonged storage The same instructions apply as for temporary storage. SPARE PARTS Spare parts may only be used by a representative who has been duly authorised/approved by PROXIPI SAS. As such, this manual does not contain a spare parts list. RATING PLATE Each component of the PROXIPI system (badge, magnetic frame, dashboard, electronic unit) has its own rating plate with an identifiable serial number.
PROXIPI user manual [EN] V2016-08     Page 8 sur 21  DECLARATIONS OF CONFORMITY This product is available in 2 versions: one compliant with the EC standard (Europe) and one compliant with the FCC and IC standards (North America). Before  using  the  products,  ensure  you  have  the  product which can be used in your region. Otherwise, do not use the products and contact us for an exchange.  Some countries may have different legislation, ensure that one or other of the frequencies is authorised in the country of use.  EC declaration of conformity The  company  PROXIPI  S.A.S.  declares  that  the product covered by this declaration complies with European directives  2004/108/EC  (EMC),  2006/95/EC  (LVD), 1999/5/EC  (R&TTE)  relating  to  the  harmonisation  of  the laws  of  countries  with  the  European  Union  regarding electromagnetic  compatibility,  low  voltage  and  radio  and telecommunications equipment.  FCC declaration of conformity This device complies with Part 15 of the FCC rules. Its use is authorised under the following two conditions:  (1) the device must not cause interference, and  (2)  the  user  of  the  device  must  accept  any  radio interference sustained, even if the interference is liable to compromise operation. Any change or modification to this product not approved by the manufacturer will cancel the user's authorisation to use the equipment. IC declaration of conformity This  device complies  with  the  CNRs of  Industrie  Canada applicable to radio devices exempt from a licence. Its use is authorised under the following two conditions:  (1) the device must not cause interference, and  (2)  the  user  of  the  device  must  accept  any  radio interference sustained, even if the interference is liable to compromise operation.
PROXIPI user manual [EN] V2016-08  Page 9 sur 21  Description of the PROXIPI system AIM OF THE PROXIPI® SYSTEM PROXIPI  SAS  designs  and  manufactures  the  PROXIPI system.  This  system  is  designed,  but  not  limited  to, preventing collisions between pedestrians and machines by two-directional warning.  However, this system is not a substitute for the safety studies allowing moving machinery and pedestrians to work alongside one another in total safety, such as, in particular,  the  installation  of  the  fork  lift  truck organisation  system  known  as  VSM  (value  stream mapping),  one-way  traffic  systems,  the  presence  of pedestrian-only areas, or the definitions of zones at risk (inside and outside), zones reserved for fork-lift trucks, zones for pallet trucks and trains, etc. Designed  and  manufactured  in  France  using  current technologies  by  qualified  personnel,  this  equipment  is designed  for  long-term  service  with  regular  maintenance reduced  to  the  simple  electrical  recharging  of  pedestrian badges.  In  addition,  we  recommend  annual  maintenance should be carried out on the system. So  as  to  meet  the  varied  requirements  of  users,  all components  of  the  PROXIPI system  may  be  customised. Moreover, components installed on the machines may be easily removed and refitted to machines of different types and makes. COMPONENTS The PROXIPI system has been designed to work mainly in the following situations:  Machine/pedestrian  detection  (use  of  Pedestrian badges)  Machine/machine detection (use of Machine badges)  Machine/zone detection (use of Zone badges) These components are all designed to work together. Their use is described below. Minimal equipment on the machine The  mobile  machine  receives  an  assembly  comprising:   Figure 1  General view of some of the devices installed on the machine.      A  magnetic  frame  (A)  installed  as  appropriate  to  the mechanical structure of the machine.  A dashboard (B) fixed in the field of view and within the audible range of the operator.  A  central  unit  containing  the management  electronics, connected to the machine battery, the magnetic frame and  the  dashboard,  and  installed  under  the  engine cover. Pedestrian badge Every pedestrian needing to be protected and warned by the PROXIPI system will be provided with a Pedestrian badge. This badge may be worn around the neck, held in a pocket or affixed to the belt according to seasonal factors or rules laid down by the company.  Figure 2  Pedestrian badge.
PROXIPI user manual [EN] V2016-08   Page 10 sur 21  Machine Badge Every machine needing to be detected to avoid a collision between  machines  will  be  fitted  with  a  Machine  badge installed on the roof.  Figure 3  Machine badge FIXED Zone Badge The  Fixed  Zone  badge  is  used  to  define  a  zone  to  be protected for the safety of personnel and/or machines.  Figure 4  FIXED Zone badge FEATURES These differ according to the carrier as follows. For the operator The operator of a machine fitted with a PROXIPI system is provided with, depending on the specifications:   A hazard proximity alert which activates as soon as one of the following is detected:  Either a pedestrian equipped with a Pedestrian badge  Or a truck equipped with a Truck badge  Or a zone fitted with a Fixed Zone badge  Access control to certain zones (RFID option)  Automatic  speed  reduction  in  the  presence  of danger through activation of the speed limiter on machines with this feature  Options  such  as  customised  audible  messages,  door opening, etc.   Figure 5  The PROXIPI system installed on a machine detects pedestrians and other machines. When a badge enters the detection area of the  machine  then,  depending  on  the  sensitivity  defined  on  the badge, the alert is triggered. For the pedestrian The pedestrian equipped with a PROXIPI badge is provided with, depending on the specifications:   A hazard proximity alert when they enter the detection zone of a truck.  Access control to certain zones.  Figure 6  The  pedestrian  badge  detects  machines  within  specified  radii. When the badge enters the detection area of the machine then, depending  on  the  sensitivity  defined  on  the  badge, the  alert  is triggered. USAGE PRINCIPLE PROXIPI  is  a  system which is  designed to warn, but  not prevent,  collisions  between  moving  machinery  and pedestrians or between the moving machines themselves. PROXIPI  is  a  safety  tool  operating  on  the  basis  of  the deployment  of  a  communicating  system.  This  system  is made up of magnetic frames, terminals and badges which operate as outlined below:  The detection distance is calculated as being the distance between the magnetic frame of the machine and the badge to be detected.  For a Pedestrian badge, the distance may vary from 0 to 15  metres  depending  on  the  specification  and  the environment.  For a Machine badge, the distance may vary from 0 to 15  metres  depending  on  the  specification  and  the environment  For a Zone badge, the distance may vary from 0 to 15 metres  depending  on  the  specification  and  the environment.
PROXIPI user manual [EN] V2016-08  Page 11 sur 21  PROXIPI IN ACTION  Note: the characteristics of the Pedestrian badge differ according  to  the  model  of  badge  chosen.  In  this section, the action described relates to the Premium badge. When  a  pedestrian  equipped  with  a  badge  enters  the detection zone of a machine, the pedestrian badge emits an audible and vibratory alarm. The machine operator  is alerted at  the  same  time  by the audible and visual alarm emitted by the dashboard installed in  their  field  of  view,  or  by  any  other  alert  specifically developed for a particular application. The pedestrian may then, depending on the specifications:  Either exit the detection zone;  Or  acknowledge  the  alert  by  pressing  the acknowledgement button on their badge (if this function is enabled) If several machines are in the pedestrian's detection area, the pedestrian will need to acknowledge the alert from each machine detected. In areas with high levels of concurrent working, an inhibition  terminal  may  be  installed.  In  this  case,  warning signs must be installed. THE ADVANTAGES OF PROXIPI® PROXIPI  technology  is  based  on  the  use  of  a  coded magnetic  field.  This  technology,  tested  by  scientific inspection laboratories, does not interfere with Wi-Fi, GPS, GSM, Bluetooth, 3G or 4G networks. The  waves  emitted  by  the  PROXIPI  system  are  below those specified in the electromagnetic field standards according to Directive 2004/40/EC. So, the emissivity and intensities  are  less  than  the  action  values  and  do  not interfere with heart pacemakers and other medical devices.              Figure 7  PROXIPI is compatible with Wi-Fi, GPS, GSM, Bluetooth, 3G and 4G networks.
PROXIPI user manual [EN] V2016-08   Page 12 sur 21  PROXIPI EquipmentSTANDARD TRUCK EQUIPMENT This  section  describes  the  standard  equipment  of  a PROXIPI system installed on a moving machine.  The PROXIPI system is powered on when the machine is started. The antenna is powered by the electronic unit. The dashboard is operational at all times and does not have an on-off switch. Thus with safety in mind, it is not possible to stop the PROXIPI system operating without carrying out work at a technical level. In the event of a malfunction requiring the PROXIPI system to be stopped, contact PROXIPI technical support or the PROXIPI approved distributor who  will  provide  the  procedure  for  stopping  the PROXIPI system. Modules installed on the machine General view The main components installed on the machine are shown below:  Figure 8  The  main  components of  the  PROXIPI  system  installed on  the machine. A. Antenna. B. Dashboard (MMI)  Electronic unit (not shown). As the antenna and the electronic unit are not used by the truck operator, they are described in the Installation manual. The dashboard, however, is described below. Dashboard (MMI) Installed  in  the  operator's  field  of  view,  the  dashboard contains  the  alarm  components  which  activate  when  a pedestrian  equipped  with  a  Pedestrian  badge,  another machine fitted with a Machine badge or entry into a zone covered by a Zone badge is detected.  Figure 9  Dashboard components. A. Frost logo B. Alarm indicators operating alternately to improve visualisation of the alarm. C. Audible alarm. D. Cable from the electronic unit. Visual and audible alarms The visual and audible intensity may be adjusted. Visual  and  audible  alarms  are  emitted  by  the  dashboard when the machine is in the safety area:  Of a Pedestrian badge;  Or  another  machine.  This  option  is  only  available  if  a machine-machine  badge  is  installed  on  each  of  the machines to be detected. The dashboard alarms are activated as follows: Visual alarm* Meaning Flashing green No badge in the zone covered by the PROXIPI system (distance defined according to the specifications) or Pedestrian badge alerts have been acknowledged. Flashing red Badge in the detection area of the machine (distance defined according to the specifications). (*)  According to configuration.  Audible alarm* Meaning Inactive No badge in the zone covered by the PROXIPI system (distance defined according to the specifications) or Pedestrian badge alerts have been acknowledged. Active Badge in the detection area of the machine (distance defined according to the specifications). (*)  According to configuration.
PROXIPI user manual [EN] V2016-08  Page 13 sur 21  Operator without badge  Use this procedure only if the machine operator does not wear the pedestrian badge. Activating the PROXIPI system When the machine starts, the two red indicator lights (Figure 10, A) of the dashboard flash quickly for 2 seconds and then turn off. An audible signal (Figure 10, B) is emitted. The PROXIPI system on the machine is then operational.  Figure 10  When the machine is started, the indicator lights (A) flash for two seconds and an audible signal (B) is emitted. Detection of a pedestrian The  detection  of  a  pedestrian  depends  on  the  distance between  the  pedestrian  and  the  machine.  This  value, defined by configuration from the data in the specifications (see  the  Installation  manual),  may  be  changed  by  the manufacturer. 1.  When a pedestrian is detected,  the  dashboard on the machine emits an audible (Figure 10, B) and visual (the two indicator lights flashing red alternately) (Figure 10, A).    The operator may not acknowledge these audible and visual alarms. 2.  The  audible  and  visual  alarms  on  the  machine dashboard  stop  automatically  when  the  pedestrian  is outside  the  configured  detection  zone  or  has acknowledged  the  badge  by  pressing  button  A  (see pedestrian badge settings). Checking operation Operator's responsibility When taking over the machine, the operator must ensure by testing  that  their  driving  assistance  device  is  in  working order. Operating anomalies If  at  least  one  of  the  modules  (antenna,  dashboard, electronic  unit)  installed  on  the  machine  is  defective,  the entire machine must be tagged out and prohibited from use until the failure is repaired. Servicing and maintenance Servicing No  particular  servicing  is  required.  It  is  recommended  to have your PROXIPI system checked each year by the initial installer.   Maintenance No specific maintenance may  be  carried  out  by the user. Annual  maintenance  of  the  equipment,  which  must  be carried out by the equipment retailer, consists of calibrating the product.  PEDESTRIAN BADGE This section describes the use of the Pedestrian badge. Description of the pedestrian badge This  badge  alerts  the  pedestrian  through  an audible  and vibratory signal when it enters the detection field of a moving machine. General view The main external components of the pedestrian badge are:  Figure 11  Components of the pedestrian badge. A. Loudspeaker, vibrator and acknowledgement push-button B. Operating lamp C. Clip for fixing to the belt or pocket D. Charging socket  Removable wrist and neck strap (not shown). Vibratory and audible alarms The  audible  (Figure  11,  A)  and  vibratory  (Figure  11,  A) alarms  are  activated  when  the  person  wearing  the pedestrian badge is in the detection zone of a machine. Audible alarm* Meaning Inactive Wearer outside the detection zone of a machine or in the detection zone after acknowledgement. Active Wearer in the detection area of a machine before manual acknowledgement.
PROXIPI user manual [EN] V2016-08   Page 14 sur 21  Active every  5 seconds              Battery low                                                         Requires charging                                         immediately. (*)  According to configuration. Vibrator* Meaning Inactive Wearer outside the detection zone of a machine or in the detection zone after acknowledgement (distance defined in the specifications). Active Wearer in the detection area of a machine before manual acknowledgement. (Distance defined in the specifications).  (*)  According to configuration. In  addition,  an  indicator  light  provides  information  on  the state of the badge. Visual alarm Meaning Green Tests the battery if the button is pressed Short bright red flashes Badge self-testing or badge in the detection zone of a machine before acknowledgement Short dim red flashes Wearer in the detection area of a machine after acknowledgement using the button. Orange Badge charging. Off Badge off-charge or charging finished. Wearer outside the detection area. Installing the badge Proceed as follows.  Position the badge around the neck using the strap, or in a pocket or on a belt using the clip (Figure 12).  Do not position the badge in the same pocket as another  electromagnetic  device  (walkie-talkie, mobile phone, lone worker protection device, etc.).  The individual wearing the badge may now be detected by any machine fitted with a PROXIPI.     Figure 12  Positioning of the badge around the neck or in a pocket.  Using the pedestrian badge  Use of the PROXIPI badge is subject to rules intended to ensure your safety and the safety of those around you. The detection of a machine fitted with an active  PROXIPI depends  on  the  distance  between  this  badge  and  the antenna  on  the  machine.  This  value  is  defined  by configuration from the data in the specifications given by the customer (see the Installation manual) and may be changed by  the  manufacturer  or  their  distributor  via  the  badge configurer.  When a machine fitted with a PROXIPI is detected, the badge  emits  an  audible  (Figure  13,  B)  and  vibratory (Figure 13, B) alarm.  The  wearer  is  then  responsible  for  taking action  by  making  themselves  safe.  No stoppage  action  is  enabled  on  the  moving machine.  Figure 13  The  operating  indicator  (A)  and  the  badge  acknowledgement button (B).  If  necessary,  acknowledge  the  audible  alarm  on  the badge by pressing the acknowledgement button (Figure 13, B).  Acknowledgement  must  be  carried  out  for  every machine present in the badge area  The  audible  and  vibratory  alarms  stop  automatically when  the  machine  is  outside  the  detection  area configured or after the badge wearer acknowledges the alarm.    The programming of the option whether or not to allow acknowledgement by  the  badge is  entirely up to the customer/end user site after a risk analysis.  Use of the Pedestrian badge by a machine operator Identification of the operator badge 1.  When the machine is powered on through  the ignition key, the operator's badge is detected and an audible and visual warning emitted. 2.  Press the acknowledgement button of the badge (Figure 14, B).   Doing this stops the audible (Figure 14, B) and vibratory alarm on the badge; the indicator (Figure 14, A) flashes red.   Figure 14  Pressing the acknowledgement button (B) stops the audible alarm (B) and the vibrator. The visual alarm (A) continues to flash.
PROXIPI user manual [EN] V2016-08  Page 15 sur 21         Charging the badge    Recap:  connecting  the  badge  charger  inhibits detection when passing near a machine fitted with a PROXIPI system. Recharge the badge as follows:  Figure 15  Charging the badge and location of the charging indicator.  Connect the micro USB plug of the charger (C) to the badge connector (A) or place the badge on its charging base (not shown).   The  charging  system  must  be  placed  in  vertical position  so  as  to  improve  heat  dissipation  of  the active components.  Insert  the  charger  (C)  into  the  mains  socket.  While charging,  the  badge  indicator  light  (B)  shows  solid orange.  Charging stops by itself. Once charging has finished, the indicator light on the badge (B) turns off (B). The badge may then be used.  The charging time is about 2 hours via the lead (Figure 15).  A  charged  badge  may  remain  connected indefinitely.  Disconnect  the  charged badge only  if  it is  to  be  used straight away. Checking the operation of the pedestrian badge with the inspection terminal Pedestrian's responsibility When  a  pedestrian  badge  is  taken,  the  pedestrian  must ensure it is operational.  To this end, every time the badge is disconnected from the charger,  the  badge  sounds  and  vibrates  to  indicate  it  is operational. If in doubt, press the badge on the button for 30 seconds until LED A goes out (figure 11) and release the button. The badge sounds and vibrates to indicate it is operational. If not, contact your supervisor.  SOUND LEVEL OF CRITICAL CHARGE/ALERT  An audible alert generates a particular SOUND every 5 to 7 seconds emitted when the battery reaches a critical discharge level of 80%  Stop using the badge straight away and place the badge on charge.             TEST TERMINAL   Test terminals are available which allow the badge to be run past the inspection  terminal  (badge reader).  This enables the functions of the badge to be tested.   If  the  badge  is  operational  (battery  charged  and electronics operational), the  green indicator on  the terminal lights up.  If  the  badge  is  not  operational  (battery  discharged and/or electronics not operational), the red indicator on the terminal lights up.  There is  a  risk  the  battery  will explode if  it  is  not charged with the charger designed for  it  or if  it is exposed to fire. Use  only  the  chargers  shown  in  the  PROXIPI catalogue. Use of any other type of charger may be dangerous  and  invalidate  the  warranty.  As  the charger is a voltage-lowering safety device, it must under  no  circumstances  be  modified,  altered  or replaced by any other item (simple mains plug etc.). Do  not  short-circuit  the  charging  terminals  of  the battery or the charger. The  battery  does  not  contain  any  replaceable components. Never try to open the badge, charger or battery. Do  not  expose  the  PROXIPI  badge  to  extreme temperatures  lower  than  -10°C  or  greater  than +55°C. The physico-chemical processes used in the batteries  set  temperature  limits  during  quick charges.  The  PROXIPI  badge  however automatically  protects  the  batteries  in  case  of extreme temperatures. An  INHIBIT  WARNING  LIGHT  option on  the  pedestrian  badge  when operating  a  machine  is  available. Contact your distributor. This allows the badge wearer to neutralise the warning light when the operator is in the driving seat.
PROXIPI user manual [EN] V2016-08   Page 16 sur 21   Figure 16  Green and red indicators on the inspection terminal. Operating anomalies If the badge does not operate correctly, it must be prohibited from use and returned to the local retailer for assessment. Servicing and maintenance Servicing Apart  from  being  regularly  charged,  the  badge  does  not require  any  special  maintenance.  It  may  be  cleaned,  if necessary,  using  electronic  wipes.  The  strap  may  be washed using hand soap for example once disconnected. Maintenance No specific maintenance may be carried out by the user. An annual inspection of the badge is recommended. This must be  carried  out  by  the  equipment  retailer.  It  consists  of checking the uniformity of magnetic detection and that the audible and vibratory alarms operate correctly. No particular servicing  is  required.  It  is  recommended  to  have  your PROXIPI system checked each year by the initial installer.   It is recommended to replace the battery every 24 MONTHS. After-sales kits are available from PROXIPI.           THE FIXED ZONE BADGE (BADGEFIX) This section describes the operation of the zone detection badge. Zone detection In the same way as when detecting a pedestrian, detecting a  zone  fitted  with  a  Zone  badge  also  depends  on  the distance between the antenna and the badge. This value, defined by configuration from the data in the specifications (see  the  Installation  manual),  may  be  changed  by  the manufacturer.  When a Zone badge is detected, the dashboard emits an audible and visual alarm.   It  is  not  possible  to  acknowledge  these  audible  and visual alarms.  The audible and visual alarms stop automatically when the  other  machine  is  outside  the  detection  area configured.  Figure 17  Zone badge. Checking operation Operator's responsibility When operators pass near a Zone badge, an interaction with the truck takes place: either alerts are triggered or the speed limiter is actuated. If this does not happen, the Zone badge and the equipment on the truck must be checked. Operating anomalies The LEDs visible on the badge ensure it is working correctly. If in doubt, contact your retailer and describe the state of the LEDs. Servicing and maintenance Servicing The badge does not require any particular maintenance. It may be cleaned, if necessary, using a slightly moist wipe. Maintenance No specific maintenance may  be  carried  out  by the user. Annual maintenance of  the badge, which must be carried out  by  the  equipment  retailer,  consists  of  calibrating  the product.    MACHINE BADGE This  section  describes  the  operation  of  the  machine  to machine detection badge. Detection of another machine  Use this procedure only if each of the machines is fitted with a specific machine to machine detection badge. In the same way as when detecting a pedestrian, detecting a machine fitted with a Machine badge also depends on the distance between the antenna and the badge. This value, defined by configuration from the data in the specifications (see  the  Installation  manual),  may  be  changed  by  the manufacturer.  When another machine fitted with a Machine badge is detected,  the  dashboard  emits  an  audible  and  visual
PROXIPI user manual [EN] V2016-08  Page 17 sur 21  alarm.   Note:  the  same  process  is  activated  on  the  other machine.   It  is  not  possible  to  acknowledge  these  audible  and visual  alarms.  However,  an  acknowledgement  button may optionally be installed.  The audible and visual alarms stop automatically when the  other  machine  is  outside  the  detection  area configured.  Figure 18  Machine badge. Checking operation Operator's responsibility When taking over the machine, the operator must ensure by testing  that  their  PROXIPI  Machine  badge  is  in  working order. Operating anomalies If at least one  of  the modules (antenna,  warning module, electronic unit, Machine badge) installed on the machine is defective,  the  entire  machine  must  be  tagged  out  and prohibited from use until the failure is repaired. Servicing and maintenance Servicing The badge does not require any particular maintenance. It may be cleaned, if necessary, using a slightly moist wipe. Maintenance No specific maintenance may  be  carried  out  by the user. Annual maintenance of  the badge, which must be carried out  by  the  equipment  retailer,  consists  of  calibrating  the product.
PROXIPI user manual [EN] V2016-08   Page 18 sur 21  Technical specificationsSTANDARD TRUCK EQUIPMENT Magnetic frame Function:  Emits an encoded magnetic field showing the presence of a machine. Transmission type: Continuous. Radius covered: From 0 to 15 metres.   Transmission power  1W at 125 kHz and 10mW at 868Mhz or 915 Mhz for US & Canada Connections:  Wired to electronics module. Attachment: May be adapted to the machine. Protection rating: IP 66. Dimensions: May be adapted to the machine. Weight: 2.5kg Electronic unit Function:  Electrical distribution of energies and interconnection of components. Connections:  5 wired outputs to the other modules via a PROXIPI BUS 1 NO/NC dry contact. 24V DC, 2 A. 2 contact activation and antenna 24 V DC on/off inputs, 2A max Alarm: Remote fault audible alert. Power supply: From 12 to 48 V DC. Electric current: 0.5 A at 12 V. External protection: 1 x 3 A slow-blow fuse to be installed by the user  Protection rating: IP 66. Dimensions:  122 x 175 x 55 (H x L x D). Weight:  550 g. Dashboard General specifications Function: Operator audible and visual alarm module.   Attachment: Fixed in the field of view and within the audible range of the operator. Electrical specifications Visual alarm device:  2 red alternating LEDS showing detection of machines and pedestrians.   Audible alarm device: Loudspeaker emitting either a special modulated signal audible   through the usual audible protection systems or optionally a voice message.  Acknowledgement: None. Connections:  Wired to the electronic module by a single cable Mechanical specifications Dimensions (mm): 142 x 40 x 30 (L x H x D). Weight (g): 110 g Material: Black PC/ABS. Environmental specifications Usage temperature: From -10 °C to + 65 °C. Hygrometry: From 15 to 90% non-condensed relative humidity (continuous operation) Protection rating: IP 54.
PROXIPI user manual [EN] V2016-08  Page 19 sur 21  PEDESTRIAN BADGE General specifications Function: Receiver badge intended to prevent collisions between machines and pedestrians. Detection principle: Magnetic field. Badge type: Pedestrian or machine operator  Carrying: Around the neck, on the belt or in the pocket. Radius covered: 0 to 15 metres depending on configuration. On/Off button: None, operates continually when not being charged. Start-up time:  Immediate (no presence of stop system).  Response time: Immediate as soon as entering the magnetic field of a machine.  Electrical specifications Visual alarm device:  3-colour LED (red, orange, green) depending on the type of information (module active, battery on charge/charged/discharged, machine detection). Audible alarm device: Loudspeaker emitting a special modulated signal audible through the standard audible protection systems. Configuration of the signal depending on the type of detection (machine or pedestrian) Acknowledgement: Pushbutton integrated into the loudspeaker. Acknowledgement of the audible alarm only. Safety index: According to the analysis of your case Intrinsic safety: No. Recharge: By individual charger through micro USB. Battery Li-ion, 240 mAh (not accessible). Operating time: 2 hours on alarm. 5 days on standby. Mechanical specifications Dimensions: 96 x 65 x 25 mm (H x L x D). Weight: 60 grams. Material: Black PC/ABS. Protection rating: IP 54. Environmental specifications Usage temperature: From - 10°C to + 55°C. Hygrometry: From 15 to 90% non-condensed relative humidity (IP54 model) From 0 to 99% RH non-condensed relative humidity (IP67 model).     Accessories provided Individual charger: 110-240 V AC 50/60 Hz, 0,1 A. Output 5 V DC, 1 A. Connection by USB type connector. Weight: 80 g. Wrist and neck strap   Optional accessories   Badge tester terminal Dimensions: 180 x 130 x 60 mm Power supply: 110/220V Power consumption: 12V, 100mA Meaning of LEDs: flashing red: equipment operational, no badge detected green: valid badge detected
PROXIPI user manual [EN] V2016-08   Page 20 sur 21  THE FIXED ZONE BADGE General specifications Function: Receiver badge intended for the detection of a machine in a zone. Radius covered: From 0 to 15 m (depends on the environment and the configuration) Standard inputs/outputs: 1 NO/NC dry contact. 277 VAC max – 2770 VA. 30 V DC max – 210 Watts.  Alarm: 1 x flashing green LED showing the badge is in working order. 1 x red LED showing detection Electrical specifications Visual alarm device:  None Audible alarm device: None Acknowledgement: None Safety index: According to the analysis of your case Intrinsic safety: No Power supply: 110-240 V AC 50/60 Hz Power consumption 100mA Mechanical specifications Dimensions: 130 x 130 x 130 mm (H x L x D). Weight: 850 grams. Material: Black PC/ABS. Protection rating: IP 54 / IP67 Environmental specifications Usage temperature: From - 10°C to + 65 °C. Hygrometry: From 15 to 90% non-condensed relative humidity (IP54 model) From 0 to 99% RH non-condensed relative humidity (IP67 model).
PROXIPI user manual [EN] V2016-08  Page 21 sur 21  MACHINE BADGE General specifications Function: Receiver badge fitted on a truck and designed to prevent collisions between machines. Detection principle: Magnetic field. Badge type: Machine-machine. Carrying: Fitted on the machine. Radius covered: 0 to 15 metres depending on configuration. On/Off button: None, continual operation. Start-up time:  Immediate (no presence of stop system).  Response time: Immediate as soon as entering the magnetic field of a machine.  Electrical specifications Visual alarm device:  None Audible alarm device: None Acknowledgement: None Internal memory: Keeps the last 100 detection identifiers          with time stamp. Safety index: According to the analysis of your case Intrinsic safety: No Power supply: Via the ECU (communication by CAN bus) which is connected to the truck battery Power consumption 100mA Mechanical specifications Dimensions: 130 x 130 x 130 mm (H x L X D). Weight: 850 grams. Material: Black PC/ABS. Protection rating: IP 54. Environmental specifications Usage temperature: From - 10°C to + 65 °C. Hygrometry: From 15 to 90% non-condensed relative humidity (IP54 model) From 0 to 99% RH non-condensed relative humidity (IP67 model).