Omron Okayama factory WT30 Wireless SS Terminal WT30-M01-FLK User Manual front eps

Omron Corporation Okayama factory Wireless SS Terminal WT30-M01-FLK front eps

manual

A123 4 5 6 7 8 9 0 123 4 5 6 7 8ONONFUNCTIONRS-232C MODEMAIN SUBPWRMODERUNTESTSETERR COMMUNIT No.MS WSW   NODE W   CHENTERRSSIMCAONONOFFON19 21121x10 x1 x10 x1 x10 x124VDCRS-232C012345678901234567890123456789012345678901234567890123456789WT30(1)(1)(2)5 dia.40120(2)Insert spring(3) Position the Adapter on the        WT30 and secure with screws.(2) Pull section A to the right and        lower while compressing the        spring.(1) Insert the end of section A        into the base of the Adapter.DIN RailHook the top of the WT30 over the DIN Rail.Mounting MethodNote: Remove the dust-proof label after mounting.DIN RailUnhook the WT30 from the DIN Rail.Insert a flat-blade screwdriver or other tool into the lower hook and pull down.Pull the bottom side forwards.Removal MethodAttach the adhesive non-slip feet to the bottom of the WT30  and stand the WT30 on a flat surface.Adhesive non-slip feetTable-top Mounting WT30-FT003  Surface Mounting BracketWT30-M01-FLK ANT1ANT2Mounting holeSerial Master StationNote: Tighten the WT30 mounting screws using the specified torque of  0.5 to 0.6 N·m.  Note: Tighten the WT30 mounting screws using the specified torque of  0.5 to 0.6 N·m. Note: Do not install the product in a metal panel. Doing so will decrease the wireless performance. To install the product in a panel, use either a Magnet-base  Antenna or Flat Antenna and install the Antenna on the outside of the panel. Using a DIN Rail Adapter (Installation Tool: WT30-FT001 or WT30-FT002)Mounting hole dimensions  (Unit: mm)Using a Surface Mounting BracketWT30 Terminal model        Type                 Specifications (No. of I/O points)WT30-M01-FLK       Serial Master  RS-232C WT30-SID16                                   16 DC inputs (NPN/PNP)WT30-SMD16 I/O Slaves  8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)WT30-SMD16-1    8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)Note: An Antenna is not included with the FA Wireless SS Terminals. Available Models     Model               TypeWT30-AT001 Magnet-base Antenna                            (2 antennas per set)WT30-AT002  Flat Diversity Antenna                            (1 antenna)WT30-AT003 Pencil Antenna                            (2 antennas per set) Model  TypeWT30-FT001    DIN Rail Mounting Bracket (for TH35-7.5)WT30-FT002    DIN Rail Mounting Bracket (for TH35-15)WT30-FT003    Surface Mounting Bracket (screw-mounting) (2 brackets per set)WT30-FT011    Flat Diversity Antenna Mounting Brackets (with magnets)WT30-CA2M     Antenna Extension Cable (1 cable, 2 m) Model  LengthXW2Z-0100U-3 1  mXW2Z-0200U-3 2  mXW2Z-0500U-3 5 mXW2Z-0200U-5 2  mXW2Z-0500U-5 5  mAccessoriesAntennas  Communications CablesOtherSpecificationsRatingsItem WT30-M01-FLK Serial MasterPower supply (wireless communications power supply)20 MΩ min. (at 100 VDC) between the  power supply and all I/O and I/O power supply and between the power supply  and chassisDielectric strengthPower supplyWT30-SID16/SMD16/SMD16-1 I/O Slaves20.4 to 26.4 VDC25% to 85% (with no condensation or icing)No corrosive gases−25 to 65 °C  (with no condensation or icing)IP20Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent)D-sub, 9-pin (female) Inch screws (OMRON XM2F- 0910-132 or equivalent)Ambient operating humidityAmbient environmentStorage temperatureDegree of protectionTerminal  constructionRated voltageAllowable voltage range24 VDC20.4 to 26.4 VDCPower consumptionError output/ output power supply (for  output circuits)Rated voltage 24 VDCAllowable voltage range------20 MΩ min. (at 100 VDC)  between the power supply  and chassis1,500 VAC for 1 min between the  powersupply and all I/O and I/O  power supply and between the  power supply and chassis1,500 VAC for 1 min  between power supply and chassis---−10 to 55°C (with the Terminal mounted with the dust-proof label facing up)3 W max.Wireless Interface SpecificationsOne stage using I/O slave for the serial master configuration.100 kbps         64 max.Number of I/O Slaves connectedWT30 FA Wireless SS TerminalInstruction SheetPackage ContentsTerminal labels (slaves only)Adhesive non-slip feet (master only)InstallationUsing a DIN RailAmbient operating temperatureConforms to JIS C0041: 300 m/s2 3 times each in X, Y, and Z Shock resistanceVibration resistanceJIS C0040Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of  50 m/s2,  whichever is smaller (DIN Rail mounting: single-amplitude of 0.1 mm or acceleration of 15 m/s2) 10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directionsInsulation resistanceSerial330 g max.10 mW/MHz10 sets max. (recommended)Number of stations per  areaRelay functionsBaud rate between  wireless stationsWeightConformity to Safety StandardsAlways use a Class 2 power supply to conform to UL standards.  CRC-CCITT (16 bits)Error detection methodIEC61000-4-4. 1 kV (power supply line) Specifications ItemWave type Spread Spectrum (direct sequence; SS-DS) SimplexCommunication method    2,401 to 2,480.2 MHz67 channels (based on switching)Frequency band Number of channelsTransmitter output powerNumber of simultaneously ON  I/O points 10 max.: −10 to 55 ˚C 16 max.: −10 to 50 ˚C (with the Terminal mounted with the dust-proof label facing up) ApplicationFor personal  computerFor PLCNote: Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in            environments subject to vibration. Precautions for Safe UseBe sure to observe the following precautions to ensure safe use of the product.1) Transport the product in the box in which the product was packaged, making sure the product is not subjected to excessive vibrations or shock, or dropped.2) Store the product within the specified environment. Allow the product to warm up to room temperature for at least 3 hours after it has been stored at −10 °C or lower.3) Use the product within the specified temperature and humidity ranges.4) Do not use the product in the following locations.Locations subject to extreme temperature changes resulting in condensationLocations subject to static electricity, excessive noise, or electric fieldsLocations where the product may come into contact with water, oil, or chemicalsLocations where corrosive gases or flammable gases are presentLocations where large amounts of dust or dirt are presentLocations subject to spatters, iron chips, or filings5) Do not install the product outdoors (outside a control panel).6) Use tape, cord, or other means to hold the product while adjusting the installation  position to prevent the product from damage due to falling.7) Do not install the product in areas where it will be subject to excessive external force, or in walkways.8)  Tighten the mounting screws to the specified torque of 0.5 to 0.6 N·m.9)  Provide sufficient space around the product for heat dissipation.10) Do not install the product in walkways or locations subject to traffic when installing the product outside a control panel.11) Do not reverse the power supply connection or connect the product to an AC power supply.12) Use the correct power supply voltage.13) Use AWG22 to AWG16 to connect wires for post terminals. For solid or standard wires, however, use AWG20 to AWG16 (0.52 to 1.5 mm2). The length of exposed wire is 10 mm.14) Do not apply voltage to the inputs exceeding the rated voltage range.15) Use communications cables (RS-232C cables) with a length of 15 m maximum and a load of 2,500 pF maximum.16) Do not lay communications cables (RS-232C cables) and antenna cables near other high-voltage cables or power lines.17) Use the specified cables for communications cables (RS-232C cables).18) Be sure to perform communications tests to confirm operation after wiring before  using the product.19) Always set the product after it is installed or replaced. Set the product correctly according to the manual, and be sure to perform the tests provided with the product (e.g., communications tests) before operating it.20) When operating the product without checking serial numbers, check whether an  existing system is present, and design the system carefully to prevent radio interference.21) Do not apply excess vibrations or shock to this product. Do not drop this product.22) Make sure that wiring and switch settings are correct before starting operations.23) Other wireless devices operating within the same frequency band may interfere with this product or be ad-versely affected by this product. Therefore, be sure to perform the tests provided with the product  (e.g., installation tests) before operating it.24) Make sure that the antenna is not disconnected during operation.25) Do not use this product near other devices that may malfunction due to the electromagnetic waves emit-ted by this product.26) Turn OFF the power supply before performing any wiring or replacing devices.27) Do not touch the product with wet hands.28) Dispose of the product as industrial waste.Precautions for Correct UseAlways heed these precautions to prevent faulty operation, malfunction, or adverse  affect on the product's performance and functionality.1) Communications performance will vary according to the operating environment. Always check operations before using the product.2) Do not install the antenna in a location surrounded by metal, such as in a control panel.3) Install the antenna so that it is as far away as possible from and not parallel to electric wires or metal plates.4) Do not use this product in areas exposed to extremely high humidity, near televisions or radios, near motors or drills that emit sparks, near strong magnets, or near fluorescent lights.5) Make sure that the terminal blocks, communications cables (RS-232C cables), and other items with locking devices are properly locked into place.6) Do not pull or bend cables with force.7) Do not change the mode selection switch during operation.Safety PrecautionsDefinition of Precautionary InformationWARNINGIndicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage.Precautionary InformationWARNINGUsing the FA Wireless SS Terminal near a pacemaker or other medical device may affect the operation of the medical device, possibly resulting in serious injury. Never use the FA Wireless SS Terminal near pacemakers or other medical devices. Do not use this product for real-time control.Design the system to ensure safety in the event of temporary interruptions in communications due to interference with the electromagnetic waves used for communications caused by the ambient environment and application methods.Always provide protective circuits in the network. Without protective circuits, malfunctions may possibly result in accidents that cause serious injury or significant property damage. Provide double or triple safety measures in external control circuits, such as emergency stop circuits, interlock circuits, or limit circuits, to ensure safety in the system if an abnormality occurs due to malfunction of the product or another external factor affecting the product's operation.CAUTIONMake sure that the direction and polarity (+/-) are correct when connecting terminal blocks and connec-tors. Turning ON the power to I/O circuits with the I/O cables connected in reverse, may result in a blown output fuse.Do not apply a voltage or connect a load to the outputs that exceeds the maximum switching capacity.Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to enter the product. Doing so may occasionally result in minor electric shock, fire, or malfunctions.Do not attempt to disassemble, repair, or modify the product, or touch the internal parts of the prod-uct. Doing so may occasionally result in minor electric shock, fire, or malfunctions. In Japan, disas-sembly and modification is also prohibited under Japan's Radio Law and may be punishable by law.English Hereby, Omron Corporation, declares that this WT30 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.Finnish Omron Corporation vakuuttaa täten että WT30 tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.Dutch Bij deze verklaart Omron Corporation dat deze WT30 voldoet aan de essentie"le eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.French Par la présente Omron Corporation déclare que l'appareil WT30 est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.Par la présente, Omron Corporation déclare que ce WT30 est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables.Swedish Härmed intygar Omron Corporation att denna WT30 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.Danish Härmed intygar Omron Corporation att denna WT30 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.Hiermit erklärt Omron Corporation, dass sich dieser/diese/dieses WT30 in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi) Hiermit erklärt Omron Corporation die Übereinstimmung des Gerätes WT30 mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien)GermanSuitability for UseOMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combi-nation of the products in the customer's application or use of the product.Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product.NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITH-IN THE OVERALL EQUIPMENT OR SYSTEM.  See also Product catalog for Warranty and Limitation of Liability.GreekItalian Con la presente Omron Corporation dichiara che questo WT30 è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.Por medio de la presente Omron Corporation declara que el WT30 cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.SpanishOmron Corporation declara que este WT30 está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.PortuguesOmron Corporation erklarer herved, at følgende utstyr WT30 overholder de vesentlige krav og øvrige relevante bestemmelser i direktiv 1995/5/EF.NorweigianAlulírott, Omron Corporation nyilatkozom, hogy a WT30 megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.HungarianOmron Corporation tímto prohlašuje, e tento WT30 je ve shode se základními po adavky a dalšími príslušnými ustanoveními smernice 1999/5/ES.CzechPolish1617569-7AT1FA Wireless SS TerminalsModel WT30ENG Instruction SheetThank you for purchasing this OMRON product. Read this instruction sheet and thoroughly familiarize yourself with the functions and characteristics of the product before using it. This product is designed for use by qualified personnel with knowledge of electrical systems. Keep this instruction sheet for future reference.For detailed application procedures, refer to the WT30 Operation Manual (Cat. No. N138).Noise immunityUse a DC power line less than 3 m to conform to EN standards. If a power line of 3 m or longer is required, extend the length at the Switching Power Supply’s primary side (i.e., the AC power line).Approx. 1 million writesEEPROM write lifeLeave the protective label in place when wiring the product. After completing wiring, always remove the protective label to enable proper heat dissipation. Fire may occasionally result if this precaution is not observed.WT30Wireless standards have been met for the following countries. The product cannot be used in any other countries.Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungry, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, USAFCC Notice This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Caution To ensure that the WLAN transmitter complies with current FCC regulations limiting both maximum RF output power and human exposure to radio frequency radiation, a separation distance of at least  20 cm must be maintained between the unit's antenna and the body of the user and any nearby persons at all times and in all applications and uses.Note: Changes or modifications not expressly approved by the party responsible for compliance could          void the user's authority to operate the equipment.FCC ID: RXEWT30
FUNCTIONMAIN SUBPWR ERRMODERUNTESTSETMS WSW   NODE W   CHENTERRSSIMCAONONOFF19 21121x10 x1 x10 x1Input Circuit DiagramError Output Circuit DiagramOutput Circuit Diagram (NPN)D-sub, 9-pin, Female End at WT30 Pin No.  Signal 1 2  RD 3  SD 4 5  SG 6 7 8 9    Contact Address       (North America)              10  mmInput CharacteristicsOutput/Error Output  Characteristics IndicatorApplicable modeRUN modeTEST modeNot usedI/O Slave StationOFF functionsON functionsHolds I/O status data when a communications error occurs.Clears I/O status data when a  communications error occurs.--- ---Input hold Normal modeInput filter: 100 ms Input filter: 10 msSignal strength monitor  disabled Signal strength monitor  enabledAll channels automatically  selected Specified channel selectedInstallation test function Nothing doneMax. switching current100 mA max. per output (at 20.4 to 26.4 VDC)Simultaneous usage of error output NPN/PNP is not possible. One for every two outputs except for error output circuits, which have one for every NPN/PNP output. (No fuses can be replaced by the user.)Leakage currentResidual voltage         Item                                  Specifications Input voltageAllowable voltage rangeInput impedanceInput current Input filter24 VDC20.4 to 26.4 VDC4.7 kΩ  (typical)5 mA (typical)17.4 VDC, 3.0 mA min.5.0 VDC, 1.0 mA max.10 ms/100 ms (Depends on the software used. Selected using switch.)FuseInput voltageAllowable voltage range 24 VDC20.4 to 26.4 VDC0.1 mA max.1.0 V max.Output Circuit Diagram (PNP)WT30-SMD16 WT30-SMD-16-1 InputsError output/output power supply Error output (PNP)Error output (NPN)Power supply OutputsError output (NPN)Power supply InputsError output power supply Inputs Error output (PNP)· I/O Slave Station WT30-SID16 I/O Characteristics• RS-232C Connector Wiring PrecautionsWire the signal lines separately from power lines to prevent noise interference.Do not lay wiring close to the antenna.Turn OFF the power before performing any wiring.Wire the terminals using the following post terminals and cables.Cable (AWG24 to AWG16)  single/stranded wire (0.2 to 1.5 m2)Length of exposed wire· Use a tool of the appropriate size to crimp the post terminal. Make an incision in the    cable and remove the covering so that the cable is either the same length as or    approximately 0.5 mm longer than the post terminal, as shown in the following diagram.    Make sure that no stray wires are protruding and the post terminal is not damaged.0 to 0.5 mmInsufficient length removedSurface damageStray wireCorrect ExampleIncorrect ExampleInsert a screwdriver into the screwless  terminal block as shown below, and  keeping the screwdriver inserted, pull out  the post terminal.Dust-proof Label   Remove the dust-proof label after completing wiring.Attaching Terminal Labels  (I/O Slaves Only)Attach terminal labels to the positions  shown in the following diagram.EC DECLARATION OF CONFORMITYNames of PartsSerial Master Station Unit No. switchSet the unit number of the Serial Master Station. Default value: 00Node setting switch (WNODE)Set the number of connected I/O Slave Stations. Default value: 01Channel setting switch (WCH)Set the communications frequency. Default value:  02Antenna terminal (ANT1)RS-232C TerminalConnect the PLC, personal computer, etc.Power supply terminalSupply power to the Unit.Antenna terminal (ANT2)Received signal  strength indicatorSpecial function switchFunction setting switchMake the detailed settings for RUN/TEST/SET mode.I/O Slave StationAntenna terminal (ANT1)Antenna terminal (ANT2)Channel setting switch (WCH)Set the communications frequency.                  Default value: 02Function setting switchMake the detailed settings for RUN/TEST/SET mode.Power supply terminal  Supply power  to the Unit.DisplayNo.12345678Function  ON OFFBaud rate (bps) (See note.)Total value =  0: 1,200=  1: 2,400=  2: 4,800=  3: 9,600=  4:19,200=  5: 38,400=  6: 57,600=  7: 115,200Communications  setting selectionData lengthParityStop bits1248 bitsNoneOdd1 bitDetailed settings  (settings for No. 2  to 8 used)Default settings (baud rate:  9,600 bps; data length: 7 bits;  parity: even; stop bits: 2)  Settings for No. 2 to 8 are  ignored.0007 bitsYesEven2 bitsSerial Communications Setting SwitchNote:    For example, if pins number 2, 3, and 4 are all ON, the total is 7, which corresponds to a baud rate of 115,200 bps.Wireless communications are not in progress.Communications are normal.RSSI Red/ Yellow/ GreenLit/All not litReceived Signal Strength Indicator monitor: Number of indicators lit  (received signal strength 1 to 9) Received signal strength less than 0 to 1.MS (Module Status)Green LitRed Lit A fatal error has occurred that cannot be recovered from.  Replace the WT30 Terminal.Flashing A non-fatal error has occurred that can be recovered from by resetting the system.--- Not lit Power is not being supplied or the system is resetting.WS (WirelessStatus)Green Lit The station has joined the wireless network.Flashing Permission to join wireless network received from Serial Master Station (Slave Stations)Red Lit A fatal error has occurred that cannot be recovered from.Flashing Error from which recovery is possibleNot lit---ERR(I/O Slave Station)COMM (Master Station)PWR0 to 15 (I/O Slave Station) Color Status Meaning (primary error)Green LitNot litRedYellowYellowLitNot litLitNot litLit/ Not litPower is being supplied.Power is not being supplied.Error output ON: Wireless device error or wireless communications error.Error output OFFSerial communications in progress.No serial communications.ON/OFF status for input or output signalsField strengthNumber of levelsWeak Medium Strong34The received signal strength is indicated using 10 levels. Check the communi-cations status, referring to the field strength level.CH CHx 10 x 1WCH settingCenter frequency  (MHz) x 10 x 1WCH settingCenter frequency  (MHz)123456···323334000000···333123456···2342401.02403.42405.82408.22410.62413.0···2475.42477.82480.2515253545556···8283555555···88123456···232402.2 2404.6 2407.02409.42411.82414.2··Unstable communications  rangeRange  in which  specified channel  can be used.Range  in which specified channel cannot  be used.Stable communications  rangeUnstable communications  range Stable communications  rangeApplicable modeSET modeNot usedSerial Master StationON functions OFF functionsHolds I/O status data when a  communications error occurs.Clears I/O status data when a  communications error occurs.Enables scan list Disables scan listRelays used Relays not usedSignal strength monitor disabledSignal strength monitor enabledAll channels automatically  selected Specified channel selected--- ---Scan list recognition Nothing doneRegisters specified I/O SlaveRegisters all I/O Slaves  automaticallyRecognizes serial numbers (See note.) Ignores serial numbers--- ---Function Setting Switch12345678910RUN modeTEST modeNote: The serial number refers to the product's unique  number.543219876InputOutput--------------------------- --------- ---I/O directionV G 0 1 2 3 COM 4 5 6 7 COM ERRP24 VDC 0 V 8 9 10 11 COM 12 13 14 15 COMERRNVG24 VDC 0 V 0 1 23 COM 4 5 6 7 COMERRN0 1 2 3 COM 4 5 6 7 COM ERRPInstallation/ confirmation test1234567 to10No.Received Signal Strength IndicatorFrequency Table123 4 5 6 7 8 9 0 ONFUNCTIONPWR ERRMODERUNTESTSETMS WSW   NODE W   CHENTERRSSIONONOFF19 x10 x1 x10 x10123456789012345678901234567890123456789WT30-SID16IN0 1 2 3 4 5 6 78   9  10  1 1 12 13 14 15ANT1 ANT2V G 0 1 2 3 COM 4 5 6 7 COM ERR(P)24 VDC 0 V 8 9 10 11 COM 12 13 14 15 COM ERR(N)ININ(Unit: mm)Common Dimensions for Serial Master and I/O Slave StationsDimensionsFUNCTIONRS-232CMODEANT1 ANT2PWRMODERUNTESTSETCOMMUNIT No.MS WSW   NODE W   CHENTERRSSIONONOFFON19 x10 x1 x10 x1 x10 x124 VDC 0 V RS-232C012345678901234567890123456789012345678901234567890123456789WT30-M01-FLK 123 4 5 6 7 8ONON123 4 5 6 7 8 9 07.315040 8.9851058.123R50WT30-AT002Cable bending angle  and dimensions34R382040WT30-AT0012476.62479.0Field strength  monitorRUN modeTEST modeOFF voltage/current characteristicsON voltage/current characteristics012 56 7 8 9IN 0IN 1IN 2IN 15COM (IN)• OMRON ELECTRONICS LLC (OEI)Phone: 1-847-843-7900 or 1-800-55-OMRON(Europe) OMRON Europe B.V. (OEE) Phone: 31-2356-81-300Secondary internal circuitChannels 35 to 50 cannot be set.: The shaded channels cannot be used in China.V GOUT 0OUT 1OUT 2OUT 7Secondary internal circuitFuseVGERRNERRPFuseSecondary internal circuitFuseVOUT 0OUT 1OUT 2OUT 7FuseOUT 3Secondary internal circuitGFuseFlashing TEST mode or SET mode has been activated.We hereby declare that the following product is in conformity with the requirements of the following ED Directive:Product:                   Type:  WT30 series with/without ANTENNA AT-001, AT002 or AT003, Antenna Extension Cable WT30-CA2M in connection with the Wiress TerminalsNo. of Directive:  99 /5 / ECTitle of Directive:  Radio and Telecommunications Terminal EquipmentNo. of Directive:  89 / 336 / EECTitle of Directive:  Electromagnetic CompatibilityNo. of Directive:  73 / 23 / EECTitle of Directive:  Low Voltage EquipmentThis product is designed and manufactured in accordance with the following standards.R&TTE:  EN 300 440-2 V1.1.1 EN 50371: 2002EMC:  EN 301 489-3 V1.4.1 EN 301 489-17 V1.2.1Safety:  EN 60950-1: 2001Year which the CE marking is affixed: 2005Manufacturer: Name: Omron Corporation, Wireless Components DepartmentAddress:  Shiokoji Horikawa, Shimokyo-ku, Kyoto, 600-8530 JapanDate: Signed: Representative in EU: Name:  Omron Europe B.V. Address:  Zilverenberg 2, 5234 GM's Hertogenbosch The NetherlandsDate: Wiress SS TerminalsFuseFuseStatus indicatorsSerial Communications  Setting Switch  Set the baud rate, and other communications settings.Mode selection switchStatus indicatorsReceived signal strength  indicatorSpecial function switchMode selection switchI/O terminalsConnect the contact signals.Node setting switch (WNODE)Set the unit number of the I/O Slave Station. Default value: 01I/O terminal status indicators (o to 7 or 8 to 15)The contact status is displayed.123 4 5 6 7 8 9 0 123 4 5 6 7 8FUNCTIONRS-232CMODEANT1 ANT2PWRMODERUNTESTSETCOMMUNIT No.MS WSW   NODE W   CHENTERRSSIONONOFFON19 x10 x1 x10 x1 x10 x124 VDC 0 V RS-232CWT30-M01-FLK

Navigation menu