Ohsung Electronics URCMSC400 MASTER SYSTEM CONTROLLER User Manual EMISSION TEST REPORT

Ohsung Electronics Co., Ltd. MASTER SYSTEM CONTROLLER EMISSION TEST REPORT

USERS MANUAL

Test Report No.: GETEC-E3-06-067 FCC Part 15 Subpart B EUT Type: Master system controllerAPPENDIX H : USER’S MANUAL FCC ID: OZ5URCMSC400
MSC-400 SystemNarrow Band RF Remotes TriggerAutomation of RS-232,IR and RelayControlled Components and SystemsMSC-400 Master System ControllerHigh performance audio video systems can include IR (infrared controlleddevices such as Satellite and Cable set top boxes,DVD players etc.),RS-232 (serial controlled devices such as projectors,surround soundreceivers and media servers),and Relay and Voltage controlleddevices (such as lights,drapes,curtains and blinds).The MSC-400Master System Controller is designed to seamlessly automate allof these types of devices.Installation of the MSC-400 insures thatany future purchase can be successfully integrated regardlessof its control method.Variety of User Interfaces In the MSC-400 System,there are four compatible remotecontrols which can be programmed to interface with theMaster System Controller;the MX-3000,MX-950,TX-1000 and the MX-900.All have unique options for cus-tomization to any client’s tastes and needs, up to a uniquegraphical style for every room and every user.The Combination - Ultimate Reliability, Flexibility and PowerIn a system equipped with an MSC-400,the remote control inthe hands of the user has a very easy task compared to lessersystems.Instead of sending multi-step macros (each step vulner-able to a mistake in pointing or other accidental interference),theremote sends an instantaneous digital RF (Radio Frequency) commandto the MSC-400.This RF command is constructed with a unique errorcorrection algorithm for incredible RF range and reliability.Once the RF“trigger”command is received by the MSC-400,sophisticated sensors,control ports,vast memory and machine intelligence go to work.COMPLETECONTROLCOMPLETE
Control up to 12 Devices via IR - Controlsstandard IR (Infrared) controlled audio video components.There are six IR-only outputs, and six IR or RS-232 outputs. Eachcan be individually adjusted and is compatible with rear panelIR inputs on components or can be connected to IR emitters (6IR emitters are included with the MSC-400,additional emitterscan be purchased six at a time).On/Off Status of up to 6 Devices -There are six video or voltage sensor inputs totest whether a component is On or Off.Components like DVDplayers and VCRs output video when on,no video when off.Byinstalling a URC VID Video Sensor and connecting to theMSC-400,the MSC-400 will detect that the component is on oroff.Components like CATV set top boxes have a switched outlet.If a low voltage wall adapter (5-24 V AC or DC) isplugged into the components switched outlet and then connectedto a URC VS-100 Voltage Sensor, the MSC-400 can detectwhether the component is on or off.By combining the optionalVS-100 with products from other companies that detect light,current,RF etc.the MSC-400 can reliably test on off status ofalmost any kind of component.Control up to 6 Devices via RS-232 - IRports 7-12 can be configured to be RS-232 instead of IR.The installer uses the optional URC RS232 cables and whenneeded,the URC MM6 Male to Male gender adapter to con-nect the MSC-400 to any RS-232 device that can be controlledvia TX,RX and GND only.Expand RF Range to Cover Estates,Connect up to 3 RF Receivers - The MSC-400 includes one RFX-250 RF Receiver.The receiver is separatefrom the Master System Controller to optimize freedom fromRF Interference and speed installation.Via the MSC-400s RFInputs,up to three RFX-250s can be connected.Since eachRFX-250 typically gives 50-100 feet of range, huge estates canbe given robust,reliable RF via a network of wired RF receivers.Use remotes as PC Keyboards - Via theUSB connector on the rear of the MSC-400,CompleteControl remotes can be programmed to act as PC keyboards onany Windows PC with a USB port.Control Screens,Drapes and Lifts -Via the two relay connectors and the convenient12v power outlet on the rear of the MSC-400,devices thatare controlled by applying a 12v Trigger voltage or by contacts opening and closing,can be automated by the MSC-400.New Narrow Band RFTransmission & ReceptionAny audio video system, by its very nature, includescomponents with high speed microprocessors whichproduce wide band localized RF interference. The combination of new versions of the MX-3000,MX-950,TX-1000 and the MX-900 with the RFX-250 providesultra reliable RF via the extraordinarily specific narrowband reception of the RFX-250. A new protocolenables hundreds of complex macros, each with hundreds of steps and all stored in the MSC-400 to beindividually triggered with a single button push on theremote control regardless of the interference and noisein the environment.The combination of very narrow transmissionof digitally encoded packets sent THREEtimes at digital speeds in milliseconds,assuresthat every button press on the remote will bereceived by theMSC-400. TheMSC-400’ssophisticated error correction circuitry stores all three packets andcompares them. Once two packetsare identified as identical, the MSC-400 goes to work.This new technology not only increasesrange,but increases reliability by a vastmargin. Only the Complete ControlMX-3000, MX-950, TX-1000 and MX-900 are equipped with both thenew Narrow Band Transmitters and the new RF Protocol.MX-3000 ColorTouch ScreenNarrow Band RFTransmissionTX-1000 Tablet StyleRFX-250 Narrow Band RFReceiver (Included withthe MSC-400)MX-950Hybrid LCDMX-900 Wand StyleCOMPLETE ™CONTROLCOMPLETEMSC-400 System Control Capabilities
500 Mamaroneck Avenue, Harrison, NY 10528    Phone: (914) 835-4484    Fax:(914) 835-4532www.universalremote.comCOMPLETE ™CONTROLCOMPLETEHardware Designed for Professional Installers - Equips You with Instant Diagnostic ToolsInstalling and programming the MSC-400 Master System Controller is sped enormously by a combination ofhardware and software design features.The MSC-400 is optimized for installation in a equipment rack or cabinet.Softly glowing blue and green LED’s on the front panel indicate connections, sensor status and the RFenvironment.In one glance, the professional installer can diagnose the system.When programming is required,the installer simply connects a laptop via USB cable to the front panel programming port.No controls areaccessible to the end user (even if the end user were to connect to the MSC-400’s programming port,they cannot upload the configuration).Software Designed for Professional Installers - Optimizes ProgrammingFlexibility with SPEEDMRF Editor software offers extensive control options,RS232 Two Way Diagnosis, IF/ELSE nesting logic andelaborate speed options,like the channel favorites tool,which enables installers to program dozens of numerickeypad macros in seconds.The result, no limits on yourimagination when it comes to dreaming up new features to make operation easier and fast,fast programming...Expands to Control 22 ComponentsThe unique Master/Slave programming options enables installers to combine two MSC-400’s into one equipment location with complete integration of all macros in one Master MSC-400.The two MSC-400’s areslaved together via the #12 RS-232 Ports on both units.Thus a combined system controls 22 components.SpecificationsMicroprocessor: Advanced ARM7TDMI microprocessor enables the MSC-400 to performsophisticated logic,with nested IF ELSE statements and tests of sensors and variables.Memory: 32 Megabytes of SDRAM and 64 Megabytes of NAND Flash Memory enable the MSC-400 to support vast, complex configurations.Macro Capability: Supports up to 32,640 macros of 255 steps in each macro. Since Macros can be nested as one step inside another Macro, there is no realistic limit for macro steps.Learning Capability: Standard frequencies (15kHz to 460kHz) RF Range: (Radio Frequency):50 to 100 feet, depending upon the environment RF Frequency: 418 MHz Weight: 77.6 oz.Size: 17.25" x 8.5" x 2.5"Instead of a simple macro, the MSC-400 intelligently tests each component to see whether it is on or off,thensends the exact commands needed to reconfigure the system.As a result,the system responds perfectly to theuser,as if an invisible engineer was concealed in the system cabinet, operating the system for them.MX-3000TX-1000MX-950MX-900
Notice to UserThis equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio or tele-vision reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one more ofthe following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from thatto which the receiver is connected.Consult the dealer or an experienced radio/TV technician for help.WarningChanges or modifications not expressly approved by the manufacturer could voidthe user's authority to operate the equipment.Note : The manufacturer is not responsible for any Radio or TV interferencecaused by unauthorized modifications to this equipment. Such modificationscould void the user's authority to operate the equipment.MSC-400 System Quick Reference GuideMSC-400 System Quick Reference GuideFront Views - Flip for Rear ViewsFront Views - Flip for Rear ViewsStart with the antenna angle set to 45degrees and positioned so that thelong side of the antenna is facing thecustomer’s favorite seating position.Power LED indicatesthat the MSC-400 ispowered on.USB 1 LED indicates thatthe USB Programming Port(Front Panel USB) is connected to a PC.Learning Sensor for learn-ing IR commands.Normally, learning is moreconvenient via a remote.Front Panel USB port isused ONLY for PROGRAMMINGUSB 2 LED indicates thatthe USB PC Keyboard Port(Rear Panel USB) is connected to a PC.Sensor LEDs light when aSensor is sensing that acomponent is ON (Video ispresent or Voltage is high).MSC-400Master System ControllerFront PanelRFX-250Narrow Band RF ReceiverFront PanelNOTE: MSC Editor Software is notincluded with the MSC-400. It canonly be downloaded from the URCDealer Only website. If you havenot registered yet, call your distrib-utor or sales representative for aregistration code and use theDealer Login at: www.universalremote.comStatus LED lights whenever an RFsignal is received and UNDER-STOOD. The LED will continue tolight with each step of a macro.Once the RFX-250 is correctly con-nected, the POWER LED lights.If the RF LED lights without abutton push on the remote, theRFX-250 must be moved to anew mounting location. It isreceiving in-band RF INTERFER-ENCE.When a button is pushed, theRF LED indicates a signal isdetected.45°
MSC-400 System Quick Reference GuideMSC-400 System Quick Reference GuideRear Views - Flip for Front ViewsRear Views - Flip for Front ViewsConnect ONE (only) of either of theRFX-250’s RF OUT connectors toONE (only) of either of the RF IN con-nectors on the MSC-400 using eitheryour cable or the supplied cable.Note that 5V and GND positions aredifferent on the RFX-250 compared to the MSC-400. TheData connects to Data, 5 V connects to 5V and GND con-nects to GND.USB2This port allowskeyboard controlof a PC. This portcannot be usedfor programming. DC12VPlug theincluded ACadapter inhere to powerthe MSC-400.IR InputThis port enables anIR Keypad or connect-ing block to route IRsignals to all emitters.RF InputThis port con-nects to up tothree RFX-250sin parallel.RF OutputThis port connectsto other MRF orMSC units in thesame location.IR and RS232 Outputs For RS-232: Connect to Outputs 7-12 only. Order either RS232M (Male connectorfor component) or RS232F (Female connector for component). No RS232 cablesare included with the MSC-400.For IR: Outputs 1-6 are IR only. Outputs 7-12 can be used for either RS232 or IR.Standard emitters can be used on 1-6, sleeved emitters should be used for Outputs7-12. Control the IR output level via the adjustment screws on the top panel.Video or Voltage Sensor InputsSense video via the VID-6 Video sensor (six to a box) or sensea 3-25 V AC or DC voltage via the VS-100 Voltage Sensor(Order the VS1006, six VS-100s to a box). The VS-100 VoltageSensor is necessary when using other manufacturer’s current,light or RF sensors.No video or voltage sensors are includedwith the MSC-400. Relays 1 and 2Each relay is compatible with Low Voltage applications (lessthan 30V with no more than .5 amps maximum current). Therelay can be programmed to Open, Close or Toggle its state inthree ways: 1. Latching 2. Momentary for a specified time 3.Momentary for as a long as the button is pressed and held.12V OutputThis is not programmable,simply a convenient powersupply for any Relay 1 or 2controlled device that needs12V (less than .5 amp). MSC-400 Master System Controller Rear PanelRFX-250 RF ReceiverRFX-250 Side ViewMSC-400 Rear ViewCombining Two MSC-400’s in Master Slave ConfigurationMasterSlaveWhen configuring two MSC-400’s to be a single Master/Slave combination, the following connec-tions must be made:A.All RFX-250s must be connected to the MASTER (10’ cable is included).B.The MASTER RF OUT is connected to the SLAVE RF IN (10’ cable is included).C. An RS232 accessory cable must connect between the #12 RS232 ports of both the MASTERand the SLAVE (this cable is not included, order the MS-01 Master/Slave cable.RS-232 Connectorfor Outputs 7-12. Noneare included with theMSC-400. Order RS232M(Male DB-9 connector forcomponent) or RS232F(Female DB-9 connectorfor component).Sleeved Emitterfor Outputs  7-12. Canbe used with 1-6 aswell.None are includ-ed with the MSC-400.Order IRS6 - Sixsleeved emitters inone box. Standard Emitter forOutputs 1-6 (can be usedtemporarily in Outputs 7-12).Compatible with MRF-300.Six are included with theMSC-400. Order IR6 - Sixemitters in one box.ABC