Nortek Security and Control 00173 Shock and Door Window Detector User Manual

Nortek Security & Control LLC Shock and Door Window Detector Users Manual

Users Manual

Copyright © 2018 Nortek Security & Control LLC 1PRINTER’S INSTRUCTIONSINSTALL INSTRUCTIONS SHOCK/DOOR / WINDOW CONTACT 2GIG-SHKDW1-345 - P/N: 10021991 X8 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11” x 17” (8.5”+8.5”) COVER: PRINT 1ST AND 4TH PAGES / INSIDE: PRINT 2ND AND 3RD PAGES - TOL: +/- 0.125”- SCALE: 1-1 - FOLDING: TO FIT BOX - FINISH WITH PAGE 1 LOGO SHOWING - SIDE 1 OF 22GIG-SHKDW1-345Shock/Door/Window Contact SensorINSTALLATION INSTRUCTIONSThe Shock/Door/Window Contact Sensor (2GIG-SHKDW1-345) is designed for use on doors, windows, and other objects that open and close. It communicates with the control panel using the 345 MHz frequency. When the surface it is mounted on is struck with sufcient force, signals are sent to the control panel. Additionally, when the magnet (which is mounted near the sensor) moves away from or closer to the door contact’s sensor, signals are transmitted to the control panel. For added protection, it is also equipped with a cover and magnetic tamper detection.Magnetic Tamper DetectionThe 2GIG Shock/Door/Window Contact Sensor is equipped with Magnetic Tamper Detection.  When enabled (see Enable / Disable Magnet Detection) the device can detect if a foreign magnet is brought within it’s detection range.  This will trigger a Tamper alert to the control panel indicating a possible attempt to bypass the device.If this were to occur, the device will stop transmitting and a Loss of Supervision will be noted at the control panel.  To clear this event, the Shock/Door/Window Contact Sensor will need to be re-calibrated (see Calibrating Magnet Detection).Figure 1. Shock/Door/Window Contact Sensor and MagnetCABBAADCUnder Circuit BoardA  Shock/Door/Window Contact SensorB  Magnet alignment Marks on Sensor C  Shock/Door/Window Contact MagnetA  Screw mounting holes (on backplate)B  Programming ButtonC  CR2450 Lithium battery (under circuit board)D  Battery Access Slot●1 — Shock/Door/Window Contact Sensor●1 — Rare Earth Magnet●2 — Phillips Head Mounting Screws●1 — Lithium Coin Battery (Installed)●2 — Adhesive Foam Tape (pre-applied on sensor and magnet)●1 — Window Warning StickerBox ContentsVerify that the package includes the following:Testing The Shock/Door/Window Contact Sensor Before mounting the contact at the desired location, learn it into the control panel. Then, perform a walk test utilizing a shock event as the test transmission to verify that it can establish good Radio Frequency (RF) communications with the control panel. NOTE: To learn how to program and fully test the Shock/Door/Window Contact Sensor, see the control panel’s Installation and Programming Guide. For 2GIG panels using older  irmware, this sensor may be learned in as a D/W device. Newer panel  firmwares will support shock detector equipment code type 1066. Mounting GuidelinesUse these guidelines when installing the sensor:●Mount Sensors within 100 ft (30 m) of the Control Panel.Although the transmitter may have a range of over 500 ft (150m)open air, the sensor location can have a signicant effect onrange. In open/unobstructed situations, the transmitter range maybe greater. In adverse wireless conditions, changing the sensororientation may lead to improved range.●Mount Sensors at Least 4.7 in (12 cm) Above the Floor. Placingsensors slightly above oor level helps to minimize possible sensordamage.●Window Shock and Sliding Door/Window Installation: Mountthe Shock/Door/Window Contact Sensor on the xed pane window1” from the frame for optimal performance. Place the sensor on themoving section of the door/window and the magnet in a stationarylocation. The included magnet must be within 2” of the sensor. If awider gap is required, up to 5”, use the optional DecoTrim Magnet(p/n 2GIG-DECOTRIM).●Do Not Expose Sensors to Moisture or Extreme Temperature.It is best to mount sensors in a dry location where the operatingtemperature does not exceed 0° to 130°F (-18° to 54°C).●Keep Sensors and Magnets Away from Metal/MetallicSurfaces. Keep sensors and magnets away from metal or metallicsurfaces (for example, foil). You should also avoid mountingsensors in areas where there is a large quantity of metal orelectrical wiring (for example, near a furnace or in a utility room). NOTE: Use on metal doors and windows with metal frames willsignicantly impair the performance of this sensor.Mounting The Shock/Door/Window Contact SensorUse the gure below as a guideline when mounting the contact.Figure 2. Backplate and Battery Compartment1”1”Sensor Magnet1 to 2”Sensor: Install one inch from the edge of the glass. Magnet: Install 1 to 2 inches from the Sensor.Figure 3. Standard Glass MountingTo mount the Shock/Door/Window Contact Sensor:Remove the backing form the pre-applied double-sided tape on the bottom of the Sensor and place in the desired location. NOTE: When mounting on a glass window, place the device one inch from the top or bottom and side edge of the window.
2Shock/Door/Window Contact |  Installation InstructionsCONFIGURING THE SHOCK/DOOR/WINDOW CONTACT SENSORThe Sensor comes pre-congured to detect shock on a Glass door or window. If the Sensor is to be mounted on a different surface or if the integrated Magnetic Contact is to be used, it must be congured for optimal performance. To congure the sensor:1  Mount the sensor and magnet as described in this these Installation Instructions. 2  If necessary, remove the cover by pressing in the Retaining Tab and gently swinging the top of the Sensor off the base.3  Remove the battery pull tab making sure that the battery stays rmly in place.NOTE: The LED should not be illuminated.The program button may now be used to: Initiated by these button presses:Review the Sensor Settings Press and release.Set the Shock Sensor Sensitivity Press and hold until the LED blinks once in Orange.Enable/Disable Magnet Detection Press and hold until the LED blinks Twice in Orange.Restore the Factory Default settings Press and hold until the LED blinks Three Time in Orange.Review Sensor SettingsPress and hold the program button for less than 2 seconds:● The Red LED will ash indicating the current shock sensor setting.○ One ash represents the low sensitivity setting○ Two ashes represents the medium sensitivity setting○ Three ashes represents the high sensitivity setting○ Four ashes represents the very high sensitivity setting○ Five ashes represents the glass mount setting (Default)● The Green LED then ashes indicating the Magnet Detectionsetting:○ One ash represents magnet detection has been enabled○ Two ashes represents magnet detection has been disabled(Default)Setting the Shock Sensor SensitivityTo accommodate different surface types and environmental situations that may require more or less sensitivity in the detection of shock events, ve selectable settings are available. To change the sensitivity level from the default Glass Mount to another setting, press and hold the program button for 2 to 5 seconds:● Release the program button when the Orange LED ashes onceindicating that the sensor has entered this programming mode.●Press the program button to select the new shock sensor setting○One button press selects the low sensitivity setting○Two button presses selects the medium sensitivity setting○Three button presses selects the high sensitivity setting○Four button presses selects the very high sensitivity setting○Five button presses selects the glass mount setting (Default)Each time the button is pressed the Red LED will illuminate until the button is released.NOTE: If the button is pressed six or more times such entries will be ignored and the LED will remain off and the sensor will retain the previous setting.When the button has not been pressed for a period of ve seconds, the programming mode will be exited and the Red LED will ash indicating the programmed Shock Sensitivity.Enable / Disable the Magnet DetectionThe 2GIG-SHKDW1-345 can be used as a Door / Window transmitter. The sensor is shipped with Magnet Detection disabled so this function must be enabled and calibrated if the sensor is to be used as a door/window contact sensor.Begin by pressing and holding the program button for 5 to 10 seconds:● Release the program button after the Orange LED ashes twice.●Press the program button to enable or disable the magnetdetection capability.○One button press enables magnetic detection○Two button presses disables magnetic detection (Default)Each time the button is pressed the Green LED will illuminate until the button is released.NOTE: If the button is pressed three or more times such entries will be ignored and the and magnet detection default to the previous setting.When the button has not been pressed for a period of ve seconds, the programming mode will be exited and the Green LED will ash indicating the programmed Shock Sensitivity.2  If utilizing the integrated Door/Window capability, ensure that the magnet is lined up with the middle mark on the sensor. See “Calibrating Magnet Detection” on page 3 (see Figure 1 Shock/Door/Window Contact Sensor and Magnet).NOTE: To utilize the Magnetic Contact, the sensor must be congured (see “Conguring the Shock/Door/Window Sensor” section on page 2).3  Use the pre-applied adhesive tape to secure the magnet in place.IMPORTANT: The magnet must be no more than 2.0” away from the sensor. If a wider Gap is required, use the optional DecoTrim Magnet (p/n 2GIG-DECOTRIM).4  The sensor comes congured to mount on Glass with the Magnet Detection disabled. If this is the desired operation, skip to “Finalizing the Installation” section on page 3.NOTE: If the shock sensor is being used on a door or wall, the sensor’s sensitivity must be congured (see “Conguring the Shock/Door/Window Sensor” section on page 2).
3Shock/Door/Window Contact |  Installation InstructionsInserting and Replacing the BatteriesTo insert or replace the batteries:1  Press in the Retaining Tab (A) and gently swing the top of the sensor up and off the base.2  Place a small non-metal object in the slot on the side of the sensor (see Part C,D in Figure 2, Shock / Door / Window Contact and Battery Compartment).3  Carefully push the battery out through the Battery Access slot.WARNING: Failure to follow these warnings and instructions can lead to heat generation, rupture, leakage, explosion, re, or other injury, or damage. Do not insert the battery into the compartment in the wrong direction. Always replace the battery with the same or equivalent type. Never recharge or disassemble the battery. Never place the battery in re or water. Always keep batteries away from small children. If batter-ies are swallowed, promptly see a doctor. Restore Factory SettingsPress and hold the program button for more than 10 seconds:●Release the program button after the Orange LED ashes three times.● Press and release the program button once more to conrm thatfactory defaults are to be restored. If this is not done within 5seconds, the reset function will be terminated with no change to theprogrammed settings.The Red LED will ash as per the programmed shock sensor setting then the Green LED will ash per the programmed Magnet Detection setting.1  Tilt the cover to align tab C through slot D.2  Close the cover down, and press down until tab A snaps into slot B.Finalizing the InstallationABDCFigure 4. Replacing Sensor CoverANon-Metal ObjectFigure 5. Remove/Replace BatteryInstaller Test ModeTo enter Installer Test Mode, remove the top housing from the sensor. In this mode the LED will blink to indicate specic conditions.IMPORTANT: Always dispose and/or recycle used batteries in accordance with the hazardous waste recovery and recycling regulations for your location. Your city, state, or country may also require you to comply with additional handling, recycling, and disposal requirements.1  Insert the replacement battery in the compartment. The positive (+) sign on the battery should be facing down and the negative (–) side facing up.2  The Green LED will illuminate for 2 seconds as the Device powers up.3  Replace the top case (see Finalizing the Installation, above).Event LED Color DurationShock Detected Red ON for 8 secondsMagnetic Detection Green Single BlinkMagnetic Tamper Orange Single BlinkMagnetic Calibration Required Red Double BlinkShock Detection System Test - Glass MountedFirmly tap the glass twice with a hard plastic object (screwdriver handle) within 12 inches of the sensor.  Verify that the shock event was received by the panel.  It may take up to 2 seconds for the panel to receive the notication.NOTE:  Do not strike the surface hard enough to break the glass.Calibrating Magnet DetectionWhen magnetic detection is rst enabled, the RED LED will blink to indicate that it is not calibrated. THE SENSOR MAGNET CALIBRATION MUST BE COMPLETED TO OPERATE PROPERLY. IF NOT CALIBRATED THE SENSOR WILL NOT TRANSMIT OPEN/CLOSE INFORMATION TO THE CONTROL PANEL. To calibrate the sensor:1  Mount the sensor and magnet in it’s nal location as instructed earlier in this document.2  Close the door or window.3  Press the Program button.4  LED will start blinking ORANGE.5  Open the door or window completely.6  Press the Program button again.7  LED will start blinking green8  Fully close door or window and press the Program Button within 10 seconds to complete the calibration process..9  LED will illuminate green for 2 seconds and then turn off and the calibration is complete.NOTE: If Magnet Detection is turned off then back on or if the battery is removed or replaced, the sensor will lose the Magnet Calibration setting and will have to be re-calibrated.
4Shock/Door/Window Contact |  Installation InstructionsLimited WarrantyThis Nortek Security & Control LLC product is warranted against defects in material and workmanship for two (2) years. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control LLC or through Nortek Security & Control LLC’s normal distribution channels. Nortek Security & Control LLC does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or prot, or cost of removal, installation, or reinstallation. All implied warranties for functionality, are valid only until the warranty expires. This Nortek Security & Control LLC Warranty is in lieu of all other warranties expressed or implied.10021991 X8Nortek Security & Control LLC | 2GIGFor technical support in the USA and Canada:855-2GIG-TECH (855-244-4832)Email: 2gigtechsupport@nortekcontrol.comVisit www.nortekcontrol.com for technical support hours of operation.For technical support outside of the USA and Canada:Contact your regional distributor.Visit www.2gig.com/dealers/ for a list of distributors in your region.REGULATORY INFORMATION FCC & IC NoticeThis device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s). Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interferencereceived that may cause undesired operation.1. l’appareil ne doit pas produire de brouillage, et2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,même si le brouillage est susceptible d’en compromettre le fonctionnement.This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:WARNING:Changes or modications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.SPECIFICATIONSWireless Signal Range 500 ft ( 152 m), open air, with Wireless Control PanelCode Outputs Alarm; Alarm Restore; Supervisory;  Low Battery; Tamper; Tamper RestoreTransmitter Frequency 345.00 MHzSupervisory Interval 70 minutesStatus Messages Shock - Loop 1Door/Window - Loop 2Magnet Dimensions (L x W x H) 0.91 x 0.47 x 0.35 in (23 x 12 x 9 mm)Magnet Type Rare EarthSensor Dimensions (L x W x H) 3.11 x 1.46 x 0.67 in (79 x 37 x 17 mm)Weight  Sensor - 1.12 ozMagnet - 0.32 ozHousing Material PC-ABS PlasticColor WhiteOperating Temperature 0° to 130°F (-18° to 54°C)Relative Humidity 5-95% Non-CondensingBattery (included) One (1) CR2450 Lithium batteriesEquipment Code 1066 - 2GIG Shock Sensor.Certication ETL, FCC, ICCopyright © 2018 Nortek Security & Control LLC • Reorient or relocate the receiving antenna.• Increase the separation between the equip   ent and receiver• Connect the equipment into an outlet on a circuit different from that towhich the receiver isconnected• Consult the dealer or an experienced radio/TV technician to help.We, Nortek Security & Control LLC of 5919 Sea Otter Place, Carlsbad, CA 92010, declare under our sole responsibility that the device, EUT MODEL# complies with Part 15 of the FCC rules.

Navigation menu