   Federal Communications Commission Statement  This equipment has been followed to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interferene by one of the following measures: -  Reorient or relocate the receiving antenna, -  Increase the separation between the equipment and receiver, -  Connect the equipment into and outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undersired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.                                                             Installation & Operation Manual  M360PIRZ-1   Wireless PIR Motion Sensor
Introduction Thanks for choosing this wireless PIR Motion Sensor of the home security device. The new multi-sensor consists of motion, temperature, humidity & light sensor for combing several functionality in one device; more attractive and economic consideration. This sensor is a Z-Wave TM enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave TM enabled network and it’s security framework. Every mains powered Z-Wave TM enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate “RF dead-spots”. Z-Wave TM enabled device displaying the Z-Wave TM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-Wave TM enabled networks.    This sensor monitors movement, and send Z-Wave TM signal when movement is detected inside the building.    With Temperature sensor built inside, it will send the signal out when temperature changed.    When the device is secure included into Z-Wave network, above communication will be encrypted. Product Description and Specification *** For indoor use only ***             Specification:  Package Content: Protocol: Z-Wave™ (ZM5202) Frequency Range:   908.42MHz (M360PIRZ-1)  Operating Range: Up to 100 feet line of sight Operating Temp.: -10°C~ 40°C (5°F~104°F) Battery: AAA x 2 1pc 1pc 2pc 1pc M360PIRZ-1   Adhesive tape for sensor AAA    Alkaline Battery Installation & Operation Manual   Z-Wave Command Classes: COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_ASSOCIATION_V2   COMMAND_CLASS_BATTERY   COMMAND_CLASS_CONFIGURATION   COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2   COMMAND_CLASS_NOTIFICATION_V4     COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_VERSION_V2                       COMMAND_CLASS_WAKE_UP_V2         COMMAND_CLASS_ZWAVEPLUS_INFO_V2                              - 1 - (Installation for Information) (A) – Wall Corner (C) - Ceiling  (D) – Vertical (E) - Angled (B) – Table      Program Switch
  Configuration – Motion Sensor:   Size  Value Parameter 5  1  1 ~ 255 (unsigned decimal) Minutes (default: 3 minutes) Parameter 6  1  1 ~ 7     (default: 4)                                 (Table 1)  (Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup the re-trigger time when there is no movement detected in the period of time. Default is 3 minutes. (Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most sensitive, 7 = most insensitive, default values= 4                       Installation Notice: If you are installing the entire Z-Wave TM system for the first time, please refer to the installation guide of Z-Wave TM Interface Controller before installing M360PIRZ-1. 1.  Release cover tab to open the cover and insert two AAA battery into the battery compartment and close the cover back to sensor.   2.  Press the program switch, the LED will flash 5 times which means the sensor has not been “included” yet or flash once which means the sensor has been “included” already. 3.  For “Inclusion (Auto-Inclusion)” in (adding to) a network: To add the M360PIRZ-1 to your Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode and the distance between sensor and controller is suggested to be in one meter.    Press the Program Switch of M360PIRZ-1 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, M360PIRZ-1 will go to sleep after 20 seconds.   4.  For “Exclusion” from (removing from) a network: To remove the M360PIRZ-1 from your Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion” mode, and following its instruction to delete the M360PIRZ-1 to your controller.    Press the Program Switch of M360PIRZ-1 once to be excluded.   For “Association”: Press the program switch for sending NIF, the LED will flash once and send the Wake Up Notification in 5 seconds. Put the Z-Wave TM Interface Controller into “association”, and following its instruction to associate the M360PIRZ-1 with other device.   Support grouping identifier=1. Support one association group (5 nodes).    “Association” is used for other grouping devices chain reaction. Red LED will flash once when trigger. 5.    Auto Wake Up:             Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller  6.    Battery Capacity Detection:           * Use “Battery Get” command to have the battery capacity back in % * It will detect the battery capacity automatically * Low Battery Auto Report when power is lower than 2.6V +/- 0.1V  7.    Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send out Alarm Report.    Press Program Switch 10 times within 10 seconds, M360PIRZ-1 will send the “Device Reset Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)        8.    All the rest commands depend on Z-Wave standard.      Operation         1.    Using adhesive tape to mount M360PIRZ-1 at 2 meters above surface.    To enhance proper operation, place M360PIRZ-1 on the location which can detect the room widely.      2.    Walk in front of M360PIRZ-1, sensor will send Basic set On (0xFF) , Red LED willl flash once and please refer to status report as table below.       - 5 -
3.    If no movement detected in three minutes (default is 3 minutes - based on user’s configuration setting, refer Table 1 (Parameter 5) will send Basic Set OFF (0x00), Red LED will flash once, and refer to table for status.    4.    The M360PIRZ-1 sensor equipped with tamper switch. If the tamper switch is triggered (or remove the cover), the M360PIRZ-1 sensor will send Alarm Report, LED will flash once and refer to table for status.      5.  If the tamper switch is closed (or closed the cover), M360PIRZ-1 will send Alarm Report,   and refer to table for status.      Alarm V1 (Movement & Tamper Switch) Notification V4 (Movement) Notification V4 (Tamper Switch) Alarm Type  0x07     Alarm  Level 0x00 (No movement after 3 mins) 0xFF (Motion detected)    Notification Type   0x07  0x07 Notification Event   0x08(Motion Detected)/ 0x00 (no movement after 3 mins) 0x03(remove cover)/ 0x00 (cover closed) Notification Event Parameter   0x08  0x03             6.    Support OTA Firmware update from controller.    Please refer to your controller manual and  use  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2.  To  proceed  the  OTA process.    - 6 -