Nortek Security and Control GTO Access LP6110KP GTO/PRO PROFESSIONAL KEYPAD User Manual F6100MBC new

GTO Access Systems, LLC GTO/PRO PROFESSIONAL KEYPAD F6100MBC new

Users Manual

rev - 10/30/17Moving GateAreaDriveway10'10'10'10'NEVER INSTALLany control devicewithin gray areaNEVER install the keypad portion of this system where a person can reach through the gate to activate it, or where a person can touch the gate while activating the keypad. The recommended minimum distance between the gate and keypad is 10 ft.©2017 GTO Access Systems, LLCPrinted in China for GTO  Wireless Estate Intercom Installation ManualKit Includes:A. KeypadB. Keypad CoverC. Jumper (required for hard-wired installation)D.  Keypad Battery CoverE. Base UnitF.  Base Unit Rechargeable BatteryG. TransformerH.  Screws for mounting Keypad CoverHow it Works:A visitor without an entry code presses the CALL button on the keypad. The base (indoor) unit and the keypad will ring. A user at the base (indoor) unit answers the call by pressing the PUSH TO ANSWER/TALK button. The user at the base unit then presses the GRANT PERMISSION button to allow the visitor to operate the gate. The keypad’s GRANTED light comes on, indicating that the visitor can now push any number key on the keypad to open the gate.Visitors with access codes simply use their code to operate the gate. Temporary codes can be programmed to expire within a set number of days. WIRELESSACEFGHDBPROFESSIONAL RESIDENTIALACCESSSYSTEMSWARNINGGTO Access Systems, LLC • 3121 Hartsfield Road • Tallahassee, Florida 32303Telephone (850) 575-0176 • Fax (850) 575-8912 • www.gtoinc.com • www.gtoaccess.com
Estate Intercom/Keypad FeaturesKeypad  • The keypad illuminates and beeps at the press of any key. At night, the keypad will illuminate when the proximity sensors detect motion near the keypad face.  • When a valid code is entered, the STATUS light will blink rapidly, the keypad will beep three times, and the GRANTED light turns green.  • The keypad remains active for 40 seconds after entering a valid code: pressing any key on the keypad while the gate is in motion will stop the gate; pressing any key while the gate is stopped will cause the gate to reverse direction. After 40 seconds, the keypad will beep 3 three times and go into “idle” mode, and the GRANTED light will turn off.  • If more than 20 key presses are entered without matching an Entry Code, the STATUS light will flash rapidly, an error tone will sound for 1 second, and the keypad will go into “lock-down” mode for 40 seconds.  • If more than 10 seconds elapse between key presses, the keypad will beep 3 three times and go into “idle” mode.Master and Entry Codes  • Up to 100 Entry Codes may be programmed into the keypad.  • Temporary Entry Codes can be programmed to expire within one to seven (1–7) days.  • Entry Codes remain stored in memory even when the keypad batteries go dead.   • All Entry Codes are deleted by pressing the RESET button on the keypad; Master Code defaults to “1234.”Base Unit  • The base unit is powered by a rechargeable battery (included); the charge is maintained by the transformer.   • The base unit can be disconnected from the transformer allowing it to be moved anywhere within range.   • Up to three additional base units can be added to the system. NOTE: The keypad, not the base station, initiates the call and operates the gate. The base station is for answering calls and granting “permission” for the gate to be opened.INTERCOM/KEYPAD SPECIFICATIONSFrequency 318 MHz from keypad to gate opener915 MHz from keypad to base stationMemory – Keypad Stores up to 100 four-digit entry codesPower Consumption – Keypad 60 mA when relay is closedPower Supply – Keypad Four C batteries (plus 8-24V DC/AC for hard-wired installations)Power Supply – Base Unit 9 Vdc 300 mA transformer; 3.6V Ni-MH 800 mA rechargeable battery packRange from Keypad to Base Unit 500’ wirelessRange from Reypad to Gate Opener 50’ wireless 100’ wired using 16 AWG wireRelay Output – Keypad Momentary, normally open dry contact closes for 2 seconds upon activationRelay Output Rating – Keypad 12 or 24 Vdc 100 mAWiring – Keypad Power & Relay Output 16 AWG stranded low voltage direct burial wire
1Keypad and Base Unit OverviewFront InteriorCalling Light:7XUQV5('ZKHQFDOOLQJWXUQV*5((1ZKHQFDOOLVDQVZHUHGGranted Light:7XUQV*5((1ZKHQDFFHVVSHUPLVVLRQLVJUDQWHGProgram Button:8VHGWRSURJUDP(QWU\&RGHVStatus Light:%OLQNVRQFHZKHQDQ\NH\LVSUHVVHGSURYLGHVYLVXDOIHHGEDFNZKHQSURJUDPPLQJNH\SDG3DEF9WXY6MNO20CALL4GHI7PRS1ABC8TUV5JKLPresenceSensors123456789ETD+0-ID SET RESETREQUIRES 4 “C”SIZE BATTERIES123456789ETD+0-ID SET RESETREQUIRES 4 “C”SIZE BATTERIESRelay Output:8VHGWRFRQQHFWWKHNH\SDGWRJDWHRSHQHUFRQWUROERDUGKDUGZLUHGLQVWDOODWLRQVPower Input:7RFRQQHFWNH\SDGWRJDWHRSHQHUSRZHUVRXUFHKDUGZLUHGLQVWDOODWLRQVDIP Switches:0DWFKNH\SDG',3VZLWFKVHWWLQJVWR(QWU\7UDQVPLWWHU¶V',3VZLWFKVHWWLQJVJumper:2)):LUHOHVVPRGH0+]HQDEOH 215HOD\RXWKDUGZLUHGLQVWDOODWLRQV0+]GLVDEOHReset Button:3UHVVWKLVEXWWRQIRUVHFRQGVWRSURJUDPNH\SDGWR0DVWHU&RGHGHIDXOW³´DQGGHOHWHDOORWKHUFRGHVID Set Button:8VHGWRV\QFDGGLWLRQDOEDVHXQLWVZLWKNH\SDGBattery Holder and Cover:8VH³&´EDWWHULHV FacePOWER Keypad Batt Low Grant PermissionPush To Answer/TalkEnd CallDV  9V Power Light:*5((1FKDUJLQJ5('EDWWHU\SRZHUPRGHXQSOXJJHGIURPWUDQVIRUPHU%OLQNLQJ5('ORZEDWWHU\Push To Answer/Talk Button:7RDQVZHUFDOOIURPNH\SDGSUHVVDQGKROGWRWDONUHOHDVHWROLVWHQGrant Permission Button:0XVWEHSUHVVHGEHIRUHWKHSHUVRQDWWKHNH\SDGFDQSUHVVDQ\NH\WRRSHQWKHJDWHEnd Call Button:7HUPLQDWHVWKHFDOOKeypad Battery Indicator Light:21ZKHQNH\SDGEDWWHU\LVORZPower Jack:Connect transformer to charge the EDWWHU\ID SETVOLUMEPOWEROFF ONVolume Control:&RQWUROVYROXPHOHYHORIVSHDNHUBattery Access Cover:5HFKDUJHDEOH9ROW1L0+EDWWHU\LQFOXGHGID Set Button:8VHGWRV\QFDGGLWLRQDOEDVHXQLWVZLWKNH\SDGON/OFF Switch:7XUQ2))WRFRQVHUYHEDWWHU\SRZHUBottom1. Install Keypad and Base Unit BatteriesStep 1:8QORFNWKHERWWRPRIWKHNH\SDGDQGVHSDUDWHLWIURPLWVFRYHU5HPRYHEDWWHU\FRYHUDQGLQVWDOOIRXU³&´EDWWHULHVrequiredQRWLQFOXGHG5HSODFHWKHEDWWHU\FRYHUStep 2:5HPRYHWKHEDVHXQLWEDWWHU\FRYHUXVLQJDVPDOOSKLOOLSVKHDGVFUHZGULYHU,QVWDOOWKHUHFKDUJHDEOH1L0+EDWWHU\LQFOXGHG5HSODFHEDWWHU\FRYHUID SET
22. Connect the Transformer and Test Base UnitStep 1: )LQGDFRQYHQLHQWORFDWLRQQHDUDQ$&RXWOHWWRPRXQWRUSODFHWKHEDVHXQLWStep 2: 3OXJWKHWUDQVIRUPHULQWRWKHRXWOHWDQGFRQQHFWLWWRWKHEDVHXQLW7KHEDVHXQLWFDQEHGLVFRQQHFWHGIURPWKHWUDQVIRUPHUIRUXVHLQDQRWKHUORFDWLRQ7KHEDWWHU\ZLOOODVWDSSUR[LPDWHO\IRXUKRXUVZKHQXQSOXJJHGIURPWKHWUDQVIRUPHUYou can turn the base unit OFF to conserve battery power, however it will not receive a signal.Step 3: 7HVWWKHEDVHXQLWE\SUHVVLQJWKH&$//EXWWRQRQWKHNH\SDG7KHEDVHXQLWZLOOULQJ Charge battery for 12 hours before using the system for the first time.POWERKeypadBatt LowGrant PermissionPush To Answer/TalkEnd CallDV  9VTransformer110 Vac outlet3. Install and Test KeypadFor wirelessDSSOLFDWLRQVWKHNH\SDGmustEHLQOLQHRIVLJKWRIandQRPRUHWKDQIWDZD\IURPWKHJDWHRSHQHUUHFHLYHU7HVWWKHNH\SDGUDQJHEHIRUHSHUPDQHQWO\PRXQWLQJLWStep 1:$WWKHJDWHVHWWKHNH\SDG',3VZLWFKHVWRPDWFK\RXU(QWU\7UDQVPLWWHU¶V',3VZLWFKVHWWLQJVNOTE: If you have not adjusted your gate opener’s Entry Transmitter from the factory setting, see the “Personalize Transmitter Settings” section in your gate opener’s installation manual.Step 2:7HVWWKHNH\SDGXVLQJWKHGHIDXOW0DVWHU&RGH³´,WZLOODFWLYDWHWKHJDWHStep 3:7HVWWKHNH\SDGUDQJHE\SUHVVLQJWKH&$//EXWWRQ<RXZLOOKHDUWKHEDVHXQLWULQJLQJWKURXJKWKHNH\SDGVSHDNHUStep 4:0RXQWWKHNH\SDGFRYHUXVLQJWKHVFUHZVSURYLGHG NOTE: a metal housing or metal object can affect rangeStep 5:6OLGHWKHNH\SDGLQWRWKHFRYHUDQGORFNLWYou will need to hard-wire your keypad to the gate opener if you:  • Do NOT have a GTO Entry Transmitter.  • Have a GTO Access Systems GP Series gate opener.  • Live in an area with high radio frequency interference.Skip to page 5 for instructions.123456789ETD+0-ID SET RESETIf you use this button to operate gate, put the 9th DIP Switch  in the “0” positionDual Button Entry Transmitter1 2 3 4 5 6 7 8 9 ECE A23S 12V ALKALINE BATTERY + 0 – LED Single Button Entry TransmitterIf you use this button to operate gate, put the 9th DIP Switch in the “+” positionChange the Keypad’s DIP Switch Settings NOT the Entry Transmitter Dip Switch Settings
3Program New Master Code1. Press and Release Program Button:2. Enter current Master Code:      (example: the factory default Master Code)3. Press and Release Program Button:4. Enter the Function Code:5. Press and Release Program Button:6. Enter the new Master Code:7. Press and Release Program Button:8. Enter the new Master Code again:9. Press and Release Program Button:Program Button Status Light= Your 4-digit code.4. Program the Keypad   •  A Master Code is needed to add, remove, or program Entry Codes.  • Factory default Master Code is “1234.”   • Keypad can only enter “program” mode from “idle” mode.   • Keypad will beep three times before going into “idle” mode (more than 10 seconds between key presses).  Add New Entry Code1.  2.   Master Code3.  4. Function Code5. 6.   New Entry Code7. Delete Entry Code1.  2.   Master Code3.  4. Function Code5. 6.   Code to be deleted7. Delete All Entry Codes1.  2.   Master Code3.  4. Function Code5. Add Temporary Entry Code*In step 4, you will need to enter a number from 1 through 7 to indicate the number of days until the Entry Code expires.1.  2.   Master Code3.  4.  Function Code & # of days Code will be active*5. 6.   Temporary Entry Code7. Programming Confirmed:  Keypad will beep 3 times.Error Message: Status light will flash rapidly, error tone will sound for1 second and keypad will return to “idle” mode (changes not saved).  • Entry Code is not 4 digits.   • New Master Codes don’t match (“Program New Master Code”).  • Memory is full (already 100 codes).           • No matching code is found (“Delete Entry Code”).
45. Sync Additional Base Units (optional),I\RXSXUFKDVHGDGGLWLRQDOEDVHXQLWV)0%&\RXPXVWV\QFHDFKDGGLWLRQDOXQLWZLWKWKHNH\SDGVRWKH\FDQFRPPXQLFDWHStep 1:  ,QVWDOOWKHEDWWHU\DQGWXUQWKHEDVHXQLW21Step 2:  3UHVVDQGUHOHDVHWKH³,'6(7´EXWWRQRQWKHNH\SDGStep 3:  3UHVVDQGUHOHDVHWKHQXPEHURQWKHNH\SDGWKDWFRUUHVSRQGVWRWKHEDVHXQLW\RXDUHDGGLQJ<RXZLOOKHDUDQXPEHURIEHHSVFRUUHVSRQGLQJWRWKHQXPEHU\RXSUHVVHG)RUH[DPSOHLI\RXDUHDGGLQJDVHFRQGEDVHXQLWWRWKHV\VWHPSUHVV³´WKHNH\SDGZLOOEHHS7:2WLPHV,I\RXDUHDGGLQJDWKLUGEDVHXQLWSUHVV³´WKHNH\SDGZLOOEHHS7+5((WLPHVHWFStep 4:  3UHVVWKH³,'6(7´EXWWRQRQWKHEDVHXQLWXQWLOLWEHHSVWKHQUHOHDVH<RXZLOOKHDUEHHSVIURPWKHEDVHXQLWDQGEHHSVIURPWKHNH\SDGZKLFKPHDQVWKHEDVHXQLWDQGNH\SDGDUHV\QFHGIMPORTANT: Base units need to be placed at least 10 feet apart to prevent interference6. Test the IntercomIMPORTANT:7KHEDVHXQLWDQGWKHNH\SDGFDQQRWEHZLWKLQIHHWRIHDFKRWKHUZKHQRSHUDWLQJ,IXQLWVDUHFORVHUWKDQIHHWWKHVLJQDOZLOOEHLQFRQVLVWHQWDQGHPLWIHHGEDFN+DYHVRPHRQHSUHVVWKH&$//EXWWRQRQWKHNH\SDG:KHQWKHEDVHXQLWLQVLGHWKHKRXVHULQJVSUHVVWKH$16:(5EXWWRQDQGWDONWRWKHSHUVRQDWWKHJDWHWRFKHFNWKHFRQQHFWLRQDQGUDQJH7KHQSUHVVWKH*5$173(50,66,21EXWWRQDQGKDYHWKHSHUVRQSUHVVDQ\NH\RQWKHNH\SDGWRDFWLYDWHWKHJDWHUsing the Wireless Estate IntercomNOTE: The keypad, not the base station, initiates the call and operates the gate. The base station is for answering calls and granting “permission” for the gate to be opened.Using the Intercom  3UHVVWKH&$//EXWWRQRQWKHNH\SDGWRULQJWKHEDVHXQLWLQVLGHWKHKRXVH  7KHEDVHXQLWZLOOULQJZKHQLWUHFHLYHVD&$//IURPWKHNH\SDGKROGWKH$16:(5EXWWRQWRWDONWRWKHYLVLWRUUHOHDVHWKH$16:(5EXWWRQWROLVWHQ3UHVVWKH*5$173(50,66,21EXWWRQWRDOORZWKHYLVLWRUWRRSHQWKHJDWHE\SUHVVLQJDQ\QXPEHUNH\RQWKHNH\SDG7KH(1'&$//EXWWRQWHUPLQDWHVWKHFDOO  $IWHUWKHNH\SDG¶V*5$17('OLJKWWXUQVJUHHQSUHVVDQ\QXPEHUNH\WRRSHQWKHJDWHUsing Entry Codes  :KHQDYDOLGFRGHLVHQWHUHGWKH67$786OLJKWZLOOEOLQNUDSLGO\DQGWKHNH\SDGZLOOEHHSWLPHV  7KHNH\SDGUHPDLQVDFWLYHIRUVHFRQGVDIWHUHQWHULQJDYDOLGFRGHSUHVVLQJDQ\NH\RQWKHNH\SDGZKLOHWKHJDWHLVLQPRWLRQZLOOVWRSWKHJDWHSUHVVLQJDQ\NH\ZKLOHWKHJDWHLVVWRSSHGZLOOFDXVHWKHJDWHWRUHYHUVHGLUHFWLRQ$IWHUVHFRQGVWKHNH\SDGZLOOEHHSWKUHHWLPHVDQGJRLQWR³LGOH´PRGH    ,IPRUHWKDQNH\SUHVVHVDUHHQWHUHGZLWKRXWPDWFKLQJDQ\(QWU\&RGHVWKH67$786OLJKWZLOOÀDVKUDSLGO\WKHHUURUWRQHZLOOVRXQGIRUVHFRQGDQGWKHNH\SDGZLOOJRLQWR³ORFNGRZQ´PRGHIRUVHFRQGV  ,IPRUHWKDQVHFRQGVHODSVHEHWZHHQNH\SUHVVHVWKHNH\SDGZLOOEHHSWKUHHWLPHVDQGJRLQWR³LGOH´PRGHIntercom ID CodesThis keypad and base unit are synced at the factory to communicate with each other. This base unit is considered to be “unit #1” when adding more base units to the system.ID SET buttonID SETVOLUMEPOWEROFF ONKeypad - InsideBase Unit – BottomKeypad - FrontID SET button3DEF9WXY6MNO20CALL4GHI7PRS1ABC8TUV5JKL123456789ETD+0-ID SET RESET
5123456789ETD+0-ID SET RESETHard-wirefromGate OpenerPower Supplyfrom OpenerBattery#1#2POWERRELAYJumper ONwireless modeJumper OFFwired modeHARD-WIRED INSTALLATION <RXZLOOQHHGWZRSDLUVRIJDXJH$:*VWUDQGHGGLUHFWEXULDOORZYROWDJHZLUHRB509RQHSDLUWRKDUGZLUHWKHFRPPXQLFDWLRQEHWZHHQWKHNH\SDGDQGWKHJDWHRSHQHUWKHRWKHUWRH[HQGWKHOLIHRIWKHIRXU³&´EDWWHULHV127(7KHIRXU³&´EDWWHULHVDUHUHTXLUHGIRUUHOLDEOHRSHUDWLRQRIWKHNH\SDGStep 1:7XUQWKHJDWHRSHQHU¶VSRZHUVZLWFK2))Step 2: 'HWHUPLQHKRZWKHZLUHVZLOOHQWHUWKHNH\SDGHJIURPWKHEDFNWKURXJKDKROHGULOOHGLQWKHSRVWUXQQLQJWKHZLUHRQWKHSRVWVXUIDFH'ULOODKROHLQWKHEDFNRIWKHNH\SDGFRYHUDQGSXOOWKHZLUHLQWRWKHFRYHU7KHQPRXQWWKHFRYHUWRWKHSRVWXVLQJWKHVFUHZVSURYLGHG5XQZLUHWKURXJK39&SLSHIURPWKHJURXQGWRNH\SDGDQGIURPWKHJURXQGWRWKHRSHQHUFRQWUROERDUGWRSURWHFWLWIURPODZQPRZHUVRUJUD]LQJDQLPDOVStep 3::LUHWKHNH\SDGWRWKHJDWHRSHQHUFRQWUROERDUG6WULS´RIIWKHHQGVRIRQHSDLURIORZYROWDJHZLUHV$WWDFKWKHZLUHVWRWKHWHUPLQDOEORFNPDUNHG5(/$<RQWKHNH\SDGFRQWUROERDUGDVVKRZQ7KHQFRQQHFWZLUHWRWKH&<&/(WHUPLQDORQWKHJDWHRSHQHUFRQWUROERDUGDQGZLUHWRWKH&20WHUPLQDORQWKHJDWHRSHQHUFRQWUROERDUG127(,I\RXKDYHDPRO 1000/2000/SL1000/SL2000 gate openerFRQQHFWZLUHWRWKH:+7DFFHVVRU\WHUPLQDODQGZLUHWRWKH*51DFFHVVRU\WHUPLQDO5HIHUWR\RXUJDWHRSHQHULQVWUXFWLRQPDQXDOIRUPRUHGHWDLOVRQZLULQJWKHJDWHRSHQHUFRQWUROERDUGStep 4: :LUHWKHNH\SDGWRWKHEDWWHU\6WULS´RIIWKHHQGVRIWKHVHFRQGSDLURIORZYROWDJHZLUHV$WWDFKWKHZLUHVWRWKHWHUPLQDOEORFNPDUNHG32:(5RQWKHNH\SDGFRQWUROERDUGDVVKRZQ&RQQHFWWKHRWKHUHQGRIWKHZLUHVWRWKHRSHQHU¶VEDWWHU\RQHHQGWRWKH326,7,9(5('WHUPLQDODQGWKHRWKHUWRWKH1(*$7,9(%/$&.WHUPLQDOStep 5:&RQQHFWWKHMXPSHUEHWZHHQWKHWZRWHUPLQDOVRQWKHNH\SDGFRQWUROERDUG21DVVKRZQStep 6:6OLGHWKHNH\SDGLQWRWKHFRYHUDQGORFNStep 7: 5HSODFHWKHJDWHRSHQHUFRQWUROERDUGFRYHUDQGWXUQWKHSRZHUVZLWFK21 Step 8:3URJUDPWKHNH\SDGSDJHDrill Hole
TroubleshootingPressing the keypad CALL button does not ring the base unit:  &KHFNWKHEDWWHULHVLQWKHNH\SDGDQGUHSODFHWKHPLIQHFHVVDU\  0DNHVXUHWKHEDVHXQLWLVWXUQHGRQDQGWKHYROXPHLVWXUQHGXS  7U\PRYLQJWKHNH\SDGDQGWKHEDVHXQLWFORVHUWRHDFKRWKHUQRFORVHUWKDQIW  3HUIRUP³6\QF´SURFHGXUHEHORZWKLVZLOOUHTXLUHWZRSHRSOH: D 2SHQWKHNH\SDGDQGORFDWHWKH³,'6(7´EXWWRQDERYHWKHEDWWHULHV/RFDWHWKH³,'6(7´EXWWRQRQWKHERWWRPRIWKHEDVHXQLW E 0DNHVXUHWKH³DQWHQQDWRDQWHQQD´GLVWDQFHEHWZHHQWKHNH\SDGDQGWKHEDVHXQLWLVDWOHDVWIHHW F 3UHVVWKH³,'6(7´EXWWRQRQWKHNH\SDGXQWLO\RXKHDUDEHHSWKHQUHOHDVH G 3UHVVWKH³,'6(7´EXWWRQRQWKHEDVHXQLWIRUDSSUR[LPDWHO\VHFRQGVWKHQUHOHDVH<RXZLOOKHDU21(EHHSIURPWKHEDVHXQLWDQG7:2IURPWKHNH\SDGZKLFKPHDQVWKHNH\SDGDQGEDVHXQLWDUHV\QFKHG H 7HVWWKHV\VWHPE\SUHVVLQJWKH&$//EXWWRQRQWKHNH\SDGWRVHHLIWKHEDVHXQLWUHFHLYHVWKHVLJQDO2QFHWKHV\VWHPLVZRUNLQJ\RXZLOOQHHGWRV\QFDGGLWLRQDOEDVHVWDWLRQVVHHSDJHThe Master Entry Code does not open the gate and the GRANTED light does not turn green.  &KHFNWKHEDWWHULHVLQWKHNH\SDGDQGUHSODFHWKHPLIQHFHVVDU\  3URJUDPWKHNH\SDGSDJHThe Master Entry Code does not open the gate and the GRANTED light turns green.:,5(/(66,QVWDOODWLRQ  9HULI\WKDW\RXU(QWU\7UDQVPLWWHURSHUDWHVWKHJDWH  9HULI\WKDWWKH.H\SDG',3VZLWFKHVDUHPDWFKHGWRWKH(QWU\7UDQVPLWWHU',36ZLWFKHVSDJH  0DNHVXUHWKH-803(5LQWKHNH\SDGLV127LQVWDOOHGSDJH:,5(',QVWDOODWLRQ  %HVXUHWKHZLUHVDUHVHFXUHO\FRQQHFWHGWRWKHJDWHRSHQHUFRQWUROERDUGSDJH  0DNHVXUHWKH-803(5LQWKHNH\SDGLVLQVWDOOHGSDJHYou’ve forgotten the Master Entry Code:The following will remove all Entry Codes from the keypad and program the Master Code back to factory default.  3UHVVDQGKROGWKH5(6(7EXWWRQLQWKHNH\SDGIRUWZRVHFRQGV0DVWHU(QWU\&RGHLVQRZ³´  3URJUDPWKHNH\SDGSDJHLimited One Year Warranty*72$FFHVV6\VWHPV//&³*72´JDWHRSHQHUDFFHVVRULHVDUHZDUUDQWHGE\WKHPDQXIDFWXUHUDJDLQVWGHIHFWVLQZRUNPDQVKLSIRUDSHULRGRIRQH\HDUIURPWKHGDWHRISXUFKDVHSURYLGHGUHFRPPHQGHGLQVWDOODWLRQSURFHGXUHVKDYHEHHQIROORZHG,QWKHFDVHRISURGXFWIDLOXUHGXHWRGHIHFWLYHPDWHULDORUPDQXIDFWXUHUZRUNPDQVKLSZLWKLQWKHRQH\HDUZDUUDQW\SHULRGWKHDFFHVVRU\ZLOOEHUHSDLUHGRUUHSODFHGDWWKHPDQXIDFWXUHU¶VRSWLRQDWQRFKDUJHWRWKHFXVWRPHULIUHWXUQHGIUHLJKWSUHSDLGWR*72$FFHVV6\VWHPV//&+DUWV¿HOG5G7DOODKDVVHH)/IMPORTANT: Call 850/575-4144 or fax 850/575-8950 for a Return Goods Authorization (RGA) number before returning goods to factory. Products received at the factory without an RGA will not be accepted. 5HSODFHPHQWRUUHSDLUHGSDUWVDUHFRYHUHGE\WKLVZDUUDQW\IRUWKHUHPDLQGHURIWKHRQH\HDUZDUUDQW\SHULRGRUVL[PRQWKVZKLFKHYHULVJUHDWHU*72ZLOOSD\WKHVKLSSLQJFKDUJHVHTXDOWR8QLWHG3DUFHO6HUYLFH*5281'UDWHIRUUHWXUQWRWKHRZQHURILWHPVUHSDLUHGXQGHUZDUUDQW\ 7KHPDQXIDFWXUHUZLOOQRWEHUHVSRQVLEOHIRUDQ\FKDUJHVRUGDPDJHVLQFXUUHGLQWKHUHPRYDORIWKHGHIHFWLYHSDUWVIRUUHSDLURUIRUWKHUHLQVWDOODWLRQRIWKRVHSDUWVDIWHUUHSDLU7KLVZDUUDQW\VKDOOEHFRQVLGHUHGYRLGLIGDPDJHWRWKHSURGXFWVZDVGXHWRLPSURSHULQVWDOODWLRQRUXVHFRQQHFWLRQWRDQLPSURSHUSRZHUVRXUFHWDPSHULQJRULIGDPDJHZDVFDXVHGE\OLJKWQLQJHOHFWULFDOSRZHUVXUJHZLQG¿UHÀRRGLQVHFWVRURWKHUQDWXUDODJHQW$IWHUWKHRQH\HDUZDUUDQW\SHULRG*72RURQHRILWVDXWKRUL]HGVHUYLFHFHQWHUVZLOOPDNHDQ\QHFHVVDU\UHSDLUVIRUDQRPLQDOIHH&DOO*72DWIRUPRUHLQIRUPDWLRQ7KLVZDUUDQW\JLYHV\RXVSHFL¿FOHJDOULJKWVDQG\RXPD\DOVRKDYHRWKHUULJKWVZKLFKPD\YDU\IURPVWDWHWRVWDWH7KLVZDUUDQW\LVLQOLHXRIDOORWKHUZDUUDQWLHVH[SUHVVHGRULPSOLHG127(9HUL¿FDWLRQRIWKHZDUUDQW\SHULRGUHTXLUHVFRSLHVRIUHFHLSWVRURWKHUSURRIRISXUFKDVH3OHDVHUHWDLQWKRVHUHFRUGVIf you have any questions or concerns, please contact our Technical Service Department Monday thru Friday 8:00 a.m. to 7:00 p.m. (ET) at 1-800-543-1236 or 850-575-4144GTO Access Systems, LLC • 3121 Hartsfield Road • Tallahassee, Florida 32303Telephone (850) 575-0176 • Fax (850) 575-8912 • www.gtoinc.com7KHFRQWHQWVRIDOOPDWHULDODYDLODEOHRQWKLVLQVWDOODWLRQPDQXDODUHFRS\ULJKWHGE\*72$FFHVV6\VWHPV//&³*72´XQOHVVRWKHUZLVHLQGLFDWHG$OOULJKWVDUHUHVHUYHGE\*72DQGFRQWHQWPD\QRWEHUHSURGXFHGGRZQORDGHGGLVVHPLQDWHGSXEOLVKHGRUWUDQVIHUUHGLQDQ\IRUPRUE\DQ\PHDQVH[FHSWZLWKWKHSULRUZULWWHQSHUPLVVLRQRI*72$Q\UHSULQWLQJRI*72SXEOLFDWLRQVLVE\SHUPLVVLRQRQO\&RS\ULJKWLQIULQJHPHQWLVDYLRODWLRQRIIHGHUDOODZ*72*723520LJKW\0XOHDUHUHJLVWHUHGWUDGHPDUNVRI*72$FFHVV6\VWHPV//&*72$FFHVV6\VWHPVLVDWUDGHPDUNRI*72$FFHVV6\VWHPV//&7KHVHPDUNVDUHWKHH[FOXVLYHSURSHUW\RI*72$FFHVV6\VWHPV//&³*72´$OOULJKWVDUHUHVHUYHGE\*72DQGWKHVHPDUNVPD\QRWEHXVHGLQDQ\IRUPZLWKRXWWKHSULRUZULWWHQSHUPLVVLRQRI*72
C5@4-:E;@41>-:@1::-;>@>-:?95@@1>Cet équipement doit être installé et utiliséavec une distance minimale de       cm entre leradiateur   ISEDC RSS warning  7KLVGHYLFHFRP SOLHVZLWK,6('&OLFHQFHH[HPSW566VWDQGDUGV2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQVWKLVGHYLFHP D\QRW FDXVHLQWHUIHUHQFHDQGWKLVGHYLFHPXVWDFFHSWDQ\LQWH UIHUHQFHLQFOXGLQJLQWHUIHUHQFHWKDWPD\FDXVHXQGHVLUHGRSHUDWLRQRIWKHGHYLFH Le présent appareil est conforme aux CNR d'ISEDC applicables aux appareils radio exempts de licence.   L'exploitation est autorisée aux deux conditions suivantes:   (1) l'appareil ne doit pas produire de brouillage, et   (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. ISEDC Radiation Exposure Statement:   7KLVHTXLS PHQWFRP SOLHVZLWK,6('&5)UDGLDWLRQH[SRVXUHOLPLWVVHWIRUWKIRUDQXQFRQWUROOHGHQYLURQP HQW7KLVWUDQVPLWWHUPXVWQRWEHFRORFDWHGRU RSHUDWLQJLQFRQMXQFWLRQZLWKDQ\RWKHUDQWHQQDRUWUDQVPLWWHURapport d'exposition de la radiation d' ISEDC :     &HWpTXLSHPHQWHVWFR QIRUPHDX[OLP LWHVGH[SRVLWLRQGDWLRQGHUDGLGHO,6('&UIGpWHUPLQpHVSRXUXQHQYLURQQHP HQWQRQFRQW U{Op&HWpP HWWHXUQHGRLWSDVrWUH &RSODFpRXIRQFWLRQQDQWGDQVODFRQMRQFWLRQDYHFDXFXQHDXWUHDQWHQQHRXpPHWWHXUThis equipment should be installed and operated with minimum distance       cm between theradiator& your body.& votre corps. ’connected.ͲͲ        2020 %.%*)2+*-/,!..!(!).&45?1=A5<91:@/;9<851?C5@4>-05-@5;:1D<;?A>18595@??1@2;>@42;>-:A:/;:@>;88101:B5>;:91:@ :0 A?1>? 9A?@ 2;88;C @41 ?<1/525/ ;<1>-@5:3 5:?@>A/@5;:? 2;> ?-@5?2E5:3 $1D<;?A>1/;9<85-:/1&45?@>-:?95@@1>9A?@:;@.1/;8;/-@10;>;<1>-@5:35:/;:6A:/@5;:Any Changes or modifications not expressly approved by the party responsible for compliance            could void the user s authority to operate the equipment.        This device complies with part 15 of the FCC Rules. Operation is subject to the following two                conditions: (1) This device may not cause harmful interference, and (2) this device must accept              any interference received, including interference that may cause undesired operation.         Note: This equipment has been tested and found to comply with the limits for a Class B digital                 device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable               protection against harmful interference in a residential installation. This equipment generates          uses and can radiate radio frequency energy and, if not installed and used in accordance with the                instructions, may cause harmful interference to radio communications. However, there is no           guarantee that interference will not occur in a particular installation. If this equipment does             cause harmful interference to radio or television reception, which can be determined by turning             the equipment off and on, the user is encouraged to try to correct the interference by one or                 more of the following measures:    ͲͲ      Reorient or relocate the receiving antenna.ͲͲ        Increase the separation between the equipment and receiver.ͲͲ                 Connect the equipment into an outlet on a circuit different from that to which the receiver isConsult the dealer or an experienced radio/TV technician for help.This equipment should be installed and operated with minimum distance       cm between theradiator& your body.20

Navigation menu