Nedap N V VELOS5 Inductive Proximity Card Reader User Manual 5277434 Quick start VP1004 1 1

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Proximity Card Reader 5277434 Quick start VP1004 1 1

User manual

  VP1004- ISO Reader Multiplexer - Quick start   9-2011 Doc.part.no. 5277434  45.01B  1/ 4   Quick start VP1004 ISO Reader Multiplexer  The Velos VP1004 is a Velos component that is used to identify animals. The VP1004 must be installed in a V-box. A VP1004 is connected to the Velos CAN-bus and controlled by a VP8001 (VPU).  Inputs / Outputs / Antennas - 8 antennas, auto scanning one by one (max 10x VP1004 per VP8001) - 2 outputs available to activate e.g. lights and  2 inputs for reading e.g. switches   FCC ID: CGDVELOS5 and IC: 1444A-VELOS5  Compliance statement (part15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Déclaration Conformité Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et  (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de cet appareil.  Warning (part15.21) Changes or modifications not expressly approved by party responsible for compliance could void the user s authority to operate the equipment. This in particular is applicable for the antenna which can be delivered with the VP4001 System. VP8001 To PC (LAN ethernet) Power Supply VP2001 max 3m VP1004 Antenna 1-8 Next VP1004 VP1004 Next VP1004 Antenna 17-24 VP1004 Antenna 9-16 VP1004 Antenna 25-32
  VP1004- ISO Reader Multiplexer - Quick start   9-2011 Doc.part.no. 5277434  45.01B  2/ 4        Connections   Details VP1004 inputs and outputs Vin + Input voltage 24 VDC, +20% -20%  - Minus CAN CH CAN high (cable twisted pair with CL)  CL CAN low (cable twisted pair with CH)   Shielding of CAN-bus cable SYNC ~ Synchronisation (no plus or minus, cable must be twisted pair)  ~ See above I/O 1 .. 2  + Output max 400mA  O Output max 400mA / 1.7A input  - Minus for output (O) and minus input (I)  I Input ANTENNA + Antenna (core)  - Antenna (shield of coax cable) F SYNC FI/FO Frequency synchronisation FI=in  FO=out  VP1004 VP1004 VP1004 VP8001 (1)  VP8001 (2) VP1004 LAN orange blue white blue black red orange white Velos cable IN Velos cable OUT (to next VP1004) antenna orange blue white blue black red orange white Velos cable Lmax = 80m     Max = 5x VP1004 Velos cable Lmax = 80m     Max = 5x VP1004
  VP1004- ISO Reader Multiplexer - Quick start   9-2011 Doc.part.no. 5277434  45.01B  3/ 4    Details Velos cable   Antennas A VP1004 has an automatic tuning module. The status is shown with LED indicators. Only V-sense antennas types can be used. Not all types are compatible, check compatibility before use. Display menu                   display  push button    DISPLAY ADDRESS Shows the actual address         SET ADDRESS Change the address        ANTENNA POWER Min/max 10 / 99. Normally set to 99. Possible to set a lower value.        ANTENNA SENSITIVITY SQUELCH Min/max 9 / 0. Normally set to 0. Possible to set a lower value.        SIGNAL LEVEL FDX Shows signal level measured by the FDX receiver        SIGNAL LEVEL HDX Shows signal level measured by the HDX receiver        TEST IDENTIFICATION Shows last 2 digits of a tag number        DISPLAY ERROR Shows error code        TEST OUTPUT L1   L5        TEST INPUT I1   i5        SETTINGS TO DEFAULT All HF settings back to factory settings (enter 99)   Press button until blinking  Press button short  To leave menu: press button until display is empty  Red (+) Black (-)  Blue (Ch) Blue/white (Cl) Shield  Orange (Sync) Orange/white (Sync) Shield Power 1,5 mm2  Communication 0,34 mm2 Twisted pair shielded  HF Synchronisation 0,34 mm2 Twisted pair shielded  Part No. 7705310
  VP1004- ISO Reader Multiplexer - Quick start   9-2011 Doc.part.no. 5277434  45.01B  4/ 4    LED indicators      POWER  Green on Power on   off No power STATUS  Blue Slow breathing Fast blinking  Operating ok Downloading or error during download Display on Address indicated No communication  off  Communication status ok V in  Green on Input power applied   off No power   Orange Low power, lower then 20V   Orange blinking Wrong CAN-bus connection, Vin and Vout swapped   Red Error, plus and minus swapped V out  Green on Output power   off No power   Orange blinking Low power   Red blinking Error, plus and minus swapped LAST  Green on  V-pack is last one on the CAN-bus   off  V-pack is not last one on the CAN-bus    Orange blinking CAN-bus error and last V-pack on CAN-bus   Red  CAN-bus error   Red blinking CAN-bus warning / wrong connected O1 .. O2  Green on Output on   off Output off   Red blinking Output error / overload I1 .. I2  Green on Input contact open   off Input contact closed ID  Green one by one Green on Antenna ok Antenna ok and tag identified   Red on Antenna error / not connected / not tuned correctly   Specifications VP 1004 Dimensions 143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr CAN CAN-bus communication 125 kBit  Power Input voltage 25 VDC, +20% -20% Min power consumption 300 mA with antenna switched on Protected against reverse connection power supply Software Downloadable by the CAN network Inputs Reading inputs, analog (0-40V) and digital. Suitable for NPN and PNP sensors. Outputs Max. 0.4 Amp by current limiter, short-circuiting protected Antennas 800 µH. Different types possible. Detection distance Varies per antenna Synchronization Synchronization according to ISO 11785 / 24631-6 Environment Temperature: Operating: -10  55 °C, Storage: -25  70 °C  Relative humidity: 10  93% non condensing IP class IP 30. When installed in V-box IP 65 (cover and cables installed correctly !) Always use a NEDAP power supply. The Nedap guarantee-regulations are only valid when is installed as indicated in this manual. Install data cables at a safe distance from (high) powered cables For more detailed information contact your local Nedap supplier or check the internet site.   This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap N.V., AGRI  P.O. Box 104 NL-7140 AC GROENLO The Netherlands