Nedap N V VELOS3 RFID Reader for Livestock User Manual manual

N. V. Nederlandsche Apparatenfabriek NEDAP RFID Reader for Livestock manual

manual

Service manual For installation, operation and service   ISO Reader Solid (CAN)      VP1101                   March 2009 / Manual version 1.0
  VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0      Version overview  Manual version 1.0 / 3-2009 First release                                          This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap N.V., AGRI  P.O. Box 104 NL-7140 AC GROENLO The Netherlands
  VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0           VP1101 ISO Reader Solid CAN        Contents  1 Introduction  1 2 Description and functioning  1 3 Safety  1 4 Installation  2 4.1 Mounting  2 4.2 Connections  2 5 Adjustments  2 6 Trouble shooting  2 7 Maintenance, cleaning and disposal  2 Appendix A: Specifications  3
  VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0
   VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0 / Page 1    Preface This manual is part of the service documentation for Nedap Velos. Reference is also made to other manuals that are part of the Nedap Velos documentation. For an overview of available Nedap Velos manuals see the manual “Nedap Velos General Description”, or visit the Nedap Agri website www.nedap-agri.com.    1 Introduction The Velos VP1001 is a Velos component that is used to identify RFID tags on animals. The VP1101 is installed close to the spot where identification is required, for example on the animal feeder.   2   Description and functioning A VP1101 is connected to the CAN-bus and can identify tags on ISO frequency 134.2 kHz. There are two types, FDX/HDX or FDX only.  3  Safety Installation and service only by trained personnel. Always turn off the main power when working on the electrical installation.                     Compliance statement (part 15.19)  This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
   VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0 / Page 2    4 Installation 4.1 Mounting See the relevant equipment manual relating to where the VP1101 is to be installed. (e.g. feeder). 4.2 Connections  Details VP1101 wiring  Brown + Input voltage 25 VDC, +20% -20% White - Minus Green CH CAN high Yellow CL CAN low Shield   Shielding of CAN-bus cable Grey ~ Synchronization (antenna) Pink ~ Synchronization (antenna)  5 Adjustments A VP1101 is pre-tuned and ready for use. No antenna adjustments required because of automatic fine tuning.  6 Trouble shooting Errors / malfunctioning are indicated at the controlling computer.  7  Maintenance, cleaning and disposal  Maintenance No regular maintenance required.  Software update By the CAN bus there is a possibility to update the software.  Cleaning A VP1101 can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids.   Disposal Discard according to the regulations prevailing at the time of disposal
   VP1101-200PM-00 ISO Reader Solid (CAN) Manual version 1.0 / Page 3    Appendix A: Specifications   Specifications VP 1101 Dimensions  2850 x 1700 x 45 mm LxWxH CAN  CAN-bus communication 125 kBit  Power  Input voltage 25 VDC, +20% -20% Power consumption 200 mA with antenna switched on Protected against reverse connection power supply Software  Downloadable by the CAN network Antennas  Internal fixed antenna Detection distance  Depending on used tags Synchronization Synchronization according to ISO 11785, ISO 24631-7 Environment  Temperature: Operating: -10 – 50 °C, Storage: -25 – 70 °C  Relative humidity: 10 – 93% non condensing IP class  IP 65.   Always use a NEDAP power supply. The Nedap guarantee-regulations are only valid when is installed as indicated in this manual. Install data cables at a safe distance from (high) powered cables  More information For more detailed information contact your local Nedap supplier or check the internet site.

Navigation menu