Nedap N V VELOS1 Inductive Proximity Tag Reader User Manual Manual

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Proximity Tag Reader Manual

Manual

 VP1001-200PM-00-ISO Reader Motor Control  Preliminary 12-2006/06      TECHNICAL MANUAL    VP1001      ISO-Reader motor control                                     This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap N.V., AGRI  P.O. Box 104 NL-7140 AC GROENLO The Netherlands
 VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0                ISO-Reader motor control          Contents   1 General  1 2 Connections  2 3 LED indicators  3 4 Display menu  4 5 Antenna adjustment  5 6 Installation steps  6 7 Update  7 8 Specifications  7
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 1     1 General The VP1001 is a local unit in the VELOS system and usually installed for identification of animals for feeding, weighing, milking, heat detection etc.  The VP1001 has the following main tasks :  - Identification of tags (134.2 kHz FDX/HDX) -  Controlling outputs, 6 outputs available to activate e.g. lights, motors, valves, relays -  Reading inputs,  6 inputs available for e.g. sensors, switches  Output/input 1 till 4 ( I/O 1 till I/O 4 ) can be used to control feed motors or as normal output/input Output/input 5 and 6 ( I/O 5 till I/O 6 ) can only be used as output/input. The use of feed motors or output/input must be configured in the software (see manual of the V-pu)  Following antenna types can be used : - V-sense antennas -  EWA transformer with stainless steel antenna strip -  HDPE antenna with HDPE antenna tuner A booster (VP1002) can be used to amplify the antenna field for high performance identification  Reference manuals : PS0000-200PM-00 Velos general overview VP8001-200PM-00 V-pu VP1002-200PM-00 ISO-Booster VP6001-200PM-00 V-sense   This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 2    2 Connections  Figure above shows the I/O of the VP1001. The motor, output and input is an example. The configuration is depending on the used software on the V-pu, so called behaviour components. Use the display menu and push button to check and configure the I/O functions.  Vin  +  Input voltage 24 VDC, +20% -20%  -  Minus CAN  CH CAN high (cable twisted pair with CL)  CL CAN low (cable twisted pair with CH)   Shielding of CAN-bus cable SYNC  ~  Synchronisation for HDX, AC (no plus or minus, cable must be twisted pair)  ~  See above I/O  1 .. 4  M  Motor output or normal output max 3A  M-  Minus for motor output or normal output  I  Input of motor or normal input  -  Minus for motor input or normal input I/O 5 .. 6  O  Output max 3A  -  Minus for output (O) and minus input (I)  I  Input ANTENNA  +  Antenna with external adjustment (adjustment not on this V-pack)   Antenna with no adjustment, adjustment on this V-pack  -  Antenna minus (shield of coax cable) F SYNC   Frequency synchronisation (not used yet)  Morangeblue white blue black red orange white green red white brown
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 3    3 LED indicators push button  display   POWER  Green on  Power on   off No power STATUS  Blue Slow blinking  Very fast blinking Fast blinking 1 short flash 2 short flashes  3 short flashes   Operating ok Service mode activ Downloading or error during download V-pack not coupled Firmware present but not activ No firmware present Display on Address indicated  No communication   off    Communication status ok V in  Green on  Input power applied   off No power   Orange  Low power, lower then 20V   Orange blinking  Wrong CAN-bus connection, Vin and Vout swapped   Red  Error, plus and minus swapped V out  Green on  Output power   off No power   Orange blinking  Low power   Red blinking  Error, plus and minus swapped LAST  Green on  V-pack is last one on the CAN-bus   off  V-pack is not last one on the CAN-bus    Orange blinking  CAN-bus error and last V-pack on CAN-bus   Red   CAN-bus error   Red blinking  CAN-bus warning / wrong connected +24V  Green on  24V output switched on   off  Output switched off M1 .. M4  Green on  Output on   off Output off   Red blinking  Output error I1 .. I4  Green on  Input contact open   off  Input contact closed TUNING /ID  Green on Green blinking  Antenna ok Antenna ok and tag identified   Red on  Antenna not tuned correctly   Red on  Antenna not tuned correctly   Red blinking  Antenna error / not connected
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 4    4 Display menu    DISPLAY ADDRESS Shows the actual address         SET ADDRESS Change the address        ADJUST ANTENNA Antenna tuning will be shown by output 6 (lamp)        ANTENNA POWER Min/max 10 / 99. Normally set to 99. Possibility to set a lower value.        ANTENNA SENSITIVITY SQUELCH Min/max 0 / 9. Normally set to 0. Possibility to set a lower value.        SETTINGS TO DEFAULT All HF settings back to factory settings        DISPLAY ERROR Shows error code         TEST ALL OUTPUTS All outputs are switch on one by one. Test results are shown on the display.         TEST MOTOR OUTPUT          TEST OUTPUT          TEST INPUT          NOISE LEVEL FDX Shows noise level measured by the FDX receiver         NOISE LEVEL HDX Shows noise level measured by the HDX receiver        TEST IDENTIFICATION Shows last 2 digits of a tag number   Press button until blinking  Press button short  To leave menu: press button until display is empty  How to use the display and push button Normally the display is off. If there is no connection to the V-pu the address is shown. It is also possible some program states of a behaviour component are shown during operation. Activate the menu   press short on the button, the display menu is shown Scroll down    press short Select      press until blinking Change and store  select item to change, open item by pressing till blinking, change by pressing        short, store by pressing to blinking Check a setting   select the item to check, press until blinking, first value shown is actual setting The display is normally automatically switched off after 30 minutes.
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 5    5 Antenna adjustments  Antenna tuning After first time power up the antenna tuning must be checked. Check the TUNING led, green is OK and means the antenna is correctly tuned. When the green led is not ON the antenna must be tuned.  Antenna tuning : -  Turn Lt on the antenna till the green led is ON (use a plastic screw driver)      Green on  Antenna tuning ok     Red on  Antenna out of range, turn to the right till green led is on     Red on  Antenna out of range, turn to the left till green led is on     Red on  No antenna connected or low antenna signal     All off  Antenna switch off by the software  If there is no antenna led on, software has set the antenna field off, first set the antenna in ID test mode by using the display/push button.   Antenna power Default the antenna power is set to maximum (99) and needs no adjustments. Lowering the antenna power will reduce the reading distance of the antenna.  Check the antenna power The antenna power level is shown on the display in the service menu at HF option AP (Adjust Power) - Select menu option AP (Adjust Power) on the display by using the push button next to the display - Push the button until the display starts to blink, a value will appear on the display - The value on the display is the actual power setting. 99 is the default factory setting. - To leave the menu without modifying the settings press the button until the display blanks (press about 4 seconds)  Modify the antenna power - Select the actual antenna power on the display (see above check antenna power) - Press the button shortly, the first value will change  - Press until the desired value, hold now the button until blinking - The second digit can be changed in the same way - When the desired value is on the display, press until the display blinks - The next menu item AS is now indicated. - To leave the service menu and return to normal operation, press the button until the display blanks (press about 4 seconds)
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 6    Antenna squelch Antenna squelch is a possibility to set a threshold for the ID level of a tag. It means the antenna power is still the same, but the software will not transfer weak received tag numbers. Default the antenna squelch is set to minimum (-0). This means no threshold. Maximum is -9.  Check the antenna squelch level The antenna squelch level is shown on the display in the service menu at HF, option AS (Adjust Squelch) - Select menu option AS (Adjust Squelch) on the display by using the push button next to the display - Push the button until the display starts to blink, a value will appear on the display - The value on the display is the actual power setting. -0 is the default factory setting. - To leave the menu without modifying the settings press the button until the display blanks (press about 4 seconds)  Modify the antenna squelch level - Select the actual antenna squelch level on the display (see above check squelch level) - Press the button shortly, the value will change  - Press until the desired value, hold now the button until blinking - The next menu item “df” is now indicated. - To leave the service menu and return to normal operation, press the button until the display blanks (press about 4 seconds)   6 Installation steps 1.  Install all wiring 2.  Switch on the power to the system 3.  Check the adjustment of the antenna (green led on) 4.  Check the connected equipment like lamps, motors, sensors etc. Use the display/push button menu to check the correct functioning. 5.  Set the addresses, an address must be unique on both CAN-bus channels 6.  Start up the web browser on the V-pu and configure the system (see manual of the V-pu)
  VP1001-200PM-00-ISO Reader Motor Control  4-2007/1.0 Page 7    7 Update  Firm ware A VP1001 is equipped with software to activate in- and outputs, display / push button and a motor safeguard. This software is called firmware. During manufacturing the firmware is programmed and ready for use. In case of an update it is possible to download new firmware thru the CAN-bus. In the Velos system the web browser interface of the V-pu (VP8001) is used to handle this. More details about download new firmware see also the manual of the V-pu (VP8001).             8 Specifications   Specifications VP 1001 (art.no. 9910905) Dimensions  143 x 120 x 68 mm LxWxH (excluding mounting rail) Weight: ± 360 gr CAN  CAN-bus communication 125 kBit  Power  Input voltage 25 VDC, +20% -20% Max power consumption 300 mA with antenna switched on Maximum power consumption 2,5 A Protected against reverse connection power supply Software  Downloadable by the CAN network Inputs  Reading inputs, analog (0-40V) and digital.  Suitable for NPN and PNP sensors. Outputs  Max. 2.5 Amp by current limiter, short-circuiting protected Motor safe-guard (after 25 sec) Antennas  800 µH. Different types possible. Detection distance  Varies per antenna Synchronisation  Synchronisation according to ISO 11785 Environment  Temperature: Operating: -10 – 55 °C, Storage: -25 – 70 °C  Relative humidity: 10 – 93% non condensing IP class  IP 30. When installed in V-box IP 65 (cover and cables installed correctly !)   Cable specifications CAN-bus Velos cable Synchronisation Velos cable Antenna  Coax RG58. Max. length depending on antenna type. Outputs  CE approved at cable length < 3m Inputs  CE approved at cable length < 3m   Always use a NEDAP power supply The Nedap guarantee-regulations are only valid when is installed as indicated in this manual. Install data cables at a safe distance from (high) powered cables  More information For more detailed information contact your local Nedap supplier or check the internet site.
 VP6001-200PM-00 V-sense  DRAFT 01-2007/0.1          VP6001  V-sense antenna                This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap N.V., AGRI  P.O. Box 104 NL-7140 AC GROENLO The Netherlands
 VP2001-200PM-00 Power supply  01-2007/0.1 Page 2 of 2     VP6001  V-sense antenna    General The VP6001 is used as antenna in Velos system and connected to a V-pack with identification.    Connections The VP6001 is connected to a V-pack by a coax cable, see manual of the concerning V-pack.  To open the VP6001 : remove screws at the side.    Adjustment Tuning must be done by Lt with a plastic screw driver. See manual of the connected V-pack for tuning instructions.    Lt To antenna of V-pack