Nedap N V UPASSACC UHF RFID reader User Manual uPASS Access

N. V. Nederlandsche Apparatenfabriek NEDAP UHF RFID reader uPASS Access

13_uPassAccess_InstallGuide_E CGDUPASSACC

2013-03-18    Doc.no. 5281326  This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifica-tions and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap AVI Page 1 of 19 uPASS Access Installation Guide
  uPASS Access  © Nedap AVI Page 2 of 19   FCC ID: CGDUPASSACC IC: 1444A-UPASSACC  Compliace statement: This device complies with part 15 of the FCC rules and to RSS210 of Industrial Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Déclaration conformitè: Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et  (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération  non pas voulu de cet appareil.  Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device shall be installed to provide a separation distance of at least 20 cm from all persons.
  uPASS Access  © Nedap AVI Page 3 of 19  CONTENTS 1 INTRODUCTION   ....................................................................................................................................................................................... 41.1 SUPPORTED TAGS   ........................................................................................................................................................................ 41.2 TAG SECURITY   ............................................................................................................................................................................... 52 INSTALLATION   ......................................................................................................................................................................................... 62.1 SAFETY INSTRUCTION   ................................................................................................................................................................ 62.2 MOUNTING INSTRUCTIONS   ...................................................................................................................................................... 63 CONNECTIONS   ......................................................................................................................................................................................... 83.1 POWER SUPPLY   ............................................................................................................................................................................. 93.2 COMMUNICATION   ....................................................................................................................................................................... 93.2.1 RS485   .................................................................................................................................................................................. 93.2.2 USB   ....................................................................................................................................................................................... 93.2.3 WIEGAND / MAGSTRIPE   ............................................................................................................................................ 103.3 LED CONTROL   ............................................................................................................................................................................. 113.4 TAMPER SWITCH   ........................................................................................................................................................................ 113.5 NEDAP ANTENNA INTERFACE   .............................................................................................................................................. 114 UHF FREQUENCIES   .............................................................................................................................................................................. 124.1 RADIO REGULATIONS   .............................................................................................................................................................. 124.2 FREQUENCY CHANNEL SELECTION   .................................................................................................................................... 125 READER CONFIGURATION   ................................................................................................................................................................ 135.1 UHFTOOL SOFTWARE   .............................................................................................................................................................. 135.2 SETTINGS   ...................................................................................................................................................................................... 135.2.1 READ DATA   .................................................................................................................................................................... 135.2.2 DECODE NEDAP XS   ..................................................................................................................................................... 145.2.3 RELAY / TIMING   ............................................................................................................................................................ 155.2.4 LED CONTROL   ............................................................................................................................................................... 155.3 EXPERT SETTINGS   ...................................................................................................................................................................... 165.3.1 OUTPUT   ........................................................................................................................................................................... 165.3.2 OUTPUT MESSAGE FORMAT   ................................................................................................................................... 165.3.3 EXTRA OUTPUT   ............................................................................................................................................................ 175.3.4 FREQUENCY   ................................................................................................................................................................... 185.3.5 READ RANGE   ................................................................................................................................................................. 18A TECHNICAL SPECIFICATIONS   .......................................................................................................................................................... 19B PART NUMBERS   .................................................................................................................................................................................... 19
  uPASS Access  © Nedap AVI Page 4 of 19  1 INTRODUCTION The uPASS Access reader offers a revolutionary and enduring solution for hands-free door access. The uPASS Access has the dimensions of a conventionally access control reader but offers read range unmatched in the industry. The uPASS Access offers identification up to 2 meter (6 feet) using the latest UHF technology.  The uPASS Access includes a RS485 interface, a wiegand/magstripe and a RF-modulation interface. The uPASS Access can also be connected to NEDAP AEOS access control hardware such as the AP1001, using the RF-modulation interface. The uPASS Access does not offer the TRANSIT compatibility features. The uPASS Access is equipped with a fixed shielded cable pigtail, 12 x 0.14 mm2In the case of extending this pigtail cable,  ONLY shielded cables shall be used and all shields shall be connected to the metal case of the external device(s). , length 5 meter (15 feet). The cable shield shall be connected to the metal case of the external device or external devices.  1.1 SUPPORTED TAGS Any EPC Class 1 Gen 2 tag is supported by the uPASS Access.  NEDAP formatted UHF tags can have the following formats:  • NEDAP UHF wiegand tags These tags will contain all wiegand information including facility code and parity bits. All wiegand formats can be supported. The reader transparently sends this information via the wiegand outputs. There is no need to change any DIP-switches or configuration settings. See chapter 3.2.3 for wiring details. Note: The Wiegand output format is determined by the tag and not by the reader.  • NEDAP UHF magstripe tags These tags will contain all magstripe information. The reader transparently sends this information onto the magstripe interface. There is no need to change any DIP-switches or configuration settings. See chapter 3.2.3 for wiring details. Note: The magstripe output format is determined by the tag and not by the reader.  • NEDAP UHF XS tag These tags are especially programmed in the same format as our 2.45GHz AVI tags (Compact-Tag, Window-Button and Heavy-Duty-Tag). The tags will also  have  a  customer-code and id-number. The reader will modulate the tag-info onto the Nedap antenna interface output, which can be connected to NEDAP AEOS access control hardware such as the AP1001. Note: See also the 'decode nedap xs' feature  as described in chapter 5.2.2.
  uPASS Access  © Nedap AVI Page 5 of 19   1.2 TAG SECURITY EPC (Electronic Product Code) tags were introduced as a possible successor to the barcode with added functionalities.  The tag emits its EPC in plain text. This makes the tags vulnerable to cloning and counterfeiting attacks. Unlike many 13MHz smartcards, EPC tags do not support any DES, 3DES or AES encryption.  EPC tags contain a data field known as the Tag Identifier (TID). At the discretion of the EPC manufacturer, the value may be factory programmed and locked, ensuring that tags have a unique identity and (theoretically) cannot be cross-copied. This TID based anti-cloning mechanism is not considered to be a strong protection.  NEDAP UHF tags support a locked serialized TID and the uPASS Access reader can be configured to read the TID data field.  In addition NEDAP has also implemented an advanced anti-cloning and anti-counterfeiting method based upon a two way authentication. This feature is supported in combination with all NEDAP UHF tags.  By default the uPASS Access reader is configured to read any EPC tag.  We encourage customers to enable the TID-check or the two way authentication. But also advise not to completely rely on these methods in high-security applications.
  uPASS Access  © Nedap AVI Page 6 of 19  2 INSTALLATION 2.1 SAFETY INSTRUCTION The following safety precautions should be observed during normal use, service and repair.  • The uPASS Access may only be installed and serviced by qualified service personnel. • Disconnect the power supply before (dis)connecting any wires, uPASS Access is NOT hot-swappable, so when making or changing connections, power must be switched OFF. • The cable shield shall be connected with safety ground and  the metal case of the external device(s). • To be sure of safety, do not modify or add anything to the uPASS Access other than mentioned in this installation guide or indicated by NEDAP N.V.  2.2 MOUNTING INSTRUCTIONS The uPASS Access can be mounted to any surface, including directly to metal. See the picture below for details about the dimensions.  Figure 1: uPASS Access dimensions (mm)  Mount the base-plate on the required location. Ensure that it is placed correctly covering the cable entry hole. Properly fix the base-plate into its position using the 2 screws. When mounting on a stone or concrete wall drill 5mm holes for the plugs. When mounting on wood, drill with 2.5mm.
  uPASS Access  © Nedap AVI Page 7 of 19   Install the uPASS Access reader onto the base-plate. 1. Feed the cable through the cable entry hole. Important note: minimum bending radius 30mm. 2. Attach the top of the uPASS Access onto the base-plate. 3. Fix the assembly using the screw on the bottom.   Figure 2: uPASS Access installation   1 2 3
  uPASS Access  © Nedap AVI Page 8 of 19  3 CONNECTIONS The uPASS Access is supplied with a 5 meter (15 feet) shielded cable pigtail with 12 multi-color wires.   RED      Power supply 12 - 24VDC.  BLACK    Power supply 0VDC, DC-Ground.  BROWN    RS485 A-  GREEN    RS485 A+  GRAY     Data-0 / Clock  PINK     Data-1 / Data  YELLOW   Tamper switch (normally closed)  GRY/PNK  Tamper switch (common)  RED/BLU  Led_UL_IN*  WHITE    Led_NA_IN*  PURPLE   Nedap antenna interface. RFMOD antenna modulation. Connect to ANT.  BLUE     Beeper_IN*  SHIELD   Shield  Note: Cable shield shall be connected to the metal case of the external device(s).  Cable extensions shall only be made by means of shielded cable(s).  All shields of the shielded cable extensions shall be connected together and to the metal case of the external device(s).  Led_UL_IN*, Led_NA_IN* and Beeper_IN* are inputs that are active LOW.
  uPASS Access  © Nedap AVI Page 9 of 19  3.1 POWER SUPPLY The uPASS Access requires DC power supply in the range from 12 – 24V. Maximum current consumption is 1A @ 12VDC, 0.5A @ 24VDC.  Connections:  RED     Power supply 12 - 24VDC.  BLACK   Power supply 0V / DC-ground.  SHIELD  Shield connected to DC-ground .  Note: Extending this connection beyond the 5 meter pig tail length shall ONLY be allowed using shielded cable.  The minimum voltage at the end of the fixed shieled pigtail cable shall be greather then 12VDC -10%  The shield shall be connected to the metal case of the external device.  3.2 COMMUNICATION 3.2.1 RS485 The uPASS Access reader has a RS485 interface for communication with a host system or for configuring reader settings. The RS485 interface is a 2-wire half-duplex serial communication interface using balanced lines.   Connections:  BROWN   RS485 A-   Balanced RX/TX  GREEN   RS485 A+ Balanced RX/TR  SHIELD  Shield connected to DC-ground.  Note: The RS485 interface is disabled while the USB interface is in use!  Extending this connection beyond the 5 meter pig tail length shall ONLY be allowed using shielded twisted pair cable(2 x 2 x 0.25 mm2 The second twisted pair shall be used for the DC power supply. ) as long as the total length is shorter then 1200 meters, 6000 feet, cable capacity < 100 pF/meter.  The shield shall be connected to the metal case of the external device.  3.2.2 USB The uPASS Access reader features an USB interface for service, installation and firmware upgrade purposes. The Mini-USB connector is located on the bottom of the device and can only be reached when the bottom screw is opened and the uPASS Access is lifted away from the base-plate. This ensures that unauthorized modifications to the reader settings can be detected using the tamper switch.  The USB interface can be used to configure the reader using the UHFTOOL software.   Note: While the shielded USB cable is connected, the RS485 interface is disabled!  The maximum shielded cable length shall be < 2 meter.   USB Driver installation Make sure your computer is connected to the internet. The driver should install automatically via Windows update when the uPASS Access reader is connected to your PC via the USB cable. Follow the driver installation wizard. If you do not see the Windows update pop-up, you can manually install the driver. To manually install, you need to go to FTDI’s website at www.ftdichip.com/Drivers/VCP.htm and download the VCP (Virtual Com Port) drivers for your operating system. Drivers for MacOS and Linux are available as well.
  uPASS Access  © Nedap AVI Page 10 of 19  3.2.3 WIEGAND / MAGSTRIPE The wiegand interface connections also support magstripe. NEDAP UHF Wiegand tags will generate a wiegand message on the interface. NEDAP UHF Magstripe tags will generate a magstripe message on the interface. Other UHF tags will not generate a message on this interface, unless the 'Extra output' settings are used!  The wiegand/magstripe output format is determined by the programmed format of the tag. Make sure to order the correct tag formatting if you want to use the wiegand or magstripe interface. See also the UHF tags order guide for more information.  Connections:  Wiegand connections Magstripe connections  GRAY    Data-0  Clock  PINK    Data-1  Data  BLACK   Ground Ground  SHIELD  Shield connected to DC-ground.    Note: Extending these connections beyond the 5 meter pig tail length shall ONLY be allowed using shielded cable (4 x 0.25 mm2 The shield shall be connected to the metal case of the external device. ) as long as the total length is shorter then 150 meters (500 feet).       3.2.3.1 WIEGAND TIMING In the figure below the Wiegand protocol timing is specified.   Tpw 5V 0V DATA-1 5V 0V DATA-0 Tpi Tpi Tpw  Timing constants: Tpi Pulse interval time 1msec Tpw Pulse width time 50µsec Figure 3: Wiegand protocol timing   3.2.3.2 MAGSTRIPE TIMING The magstripe message length is determined by the tag. The first character will be a start-sentinel (0xB). The message is terminated with an end-sentinel character (0xF) and an LRC character.  The figure below shows  the timing for one magstripe character. Each bit consists out of one period low (220µsec) and two periods high (440µsec). The Data-signal is valid and stable on the falling edge of the Clock-signal. Before and after the data 16 clock pulses are generated (postamble and preamble).   odd parity msb lsb 3300µsec 0 1 1 0 1 220µsec 660µsec 5V 0V CLK 5V 0V DAT  Timing constants: Clock period 660µsec Clock high 440µsec Clock low 220µsec Data pre-amble 16 clock periods Data post-amble 16 clock periods Figure 4: Magstripe protocol timing one character
  uPASS Access  © Nedap AVI Page 11 of 19  3.3 LED CONTROL The built-in high intensity LED provides visual feedback that the tag has been read or authorized. The LED and buzzer can be controlled by the access control system.  Automatic mode: Default the uPASS Access will automatically control the LED. During stand-by the LED will be RED and upon identification it will be GREEN. These colors can be changed!  Remote control: The LED can be controlled remotely by a connected access control system. Digital inputs will determine the color indicated on the LED. Use UHFTOOL to enable the Remote LED control mode.   RED/BLU  Led_UL_IN*  WHITE    Led_NA_IN*  BLUE     Beeper_IN*  BLACK    Ground  SHIELD   Shield connected to DC-ground.  Note: Extending these connections beyond the 5 meter pig tail length shall ONLY be allowed using shielded cable (4 x 0.25 mm2 The shield shall be connected to the metal case of the external device. ) as long as the total length is shorter then 150 meters (500 feet).  3.4 TAMPER SWITCH An internal magnet provides tamper indication when the reader is dismounted. This contact may be connected to an external alarm system. The contacts are normally closed when the reader is in place.  Tamper switches of multiple readers can be connected in series.  Connections:  YELLOW   Tamper switch (normally closed)  GRY/PNK  Tamper switch (common)  SHIELD   Shield connected to DC-ground.  Contact ratings: Max. current 50 mA (0.5 Volt voltage drop) Max. switching voltage +24 VDC  Note: Extending this connection beyond the 5 meter pig tail length shall ONLY be allowed using shielded cable (2 x 0.25 mm2 The shield shall be connected to the metal case of the external device. ) as long as the total length is shorter then 150 meters (500 feet).      3.5 NEDAP ANTENNA INTERFACE The Nedap antenna interface is used to connect the uPASS Access to NEDAP AEOS access control hardware such as the AP1001. Instead of proximity antenna the uPASS Access can be connected.  Connections:  PURPLE  Nedap antenna interface. RFMOD antenna modulation. Connect to ANT.  BLACK   Nedap antenna interface. Ground, shield. Connect to ANT GND.  SHIELD  Shield connected to DC-ground.  Note: Extending this connection beyond the 5 meter pig tail length shall ONLY be allowed using coaxial cable, RG58U,  as long as the total length is shorter then 100 meters (350 feet).  The shield shall be connected to the metal case of the external device.
  uPASS Access  © Nedap AVI Page 12 of 19  4 UHF FREQUENCIES 4.1 RADIO REGULATIONS The uPASS Access reader operates on the 860 – 960 MHz band. Regulations in this band are not standardized world-wide. Generally the regulations can be divided into several regions. Per region a specific frequency band is available. This frequency band is divided into frequency channels. If local radio regulations require frequency hopping (FHSS), then the uPASS Access automatically selects and uses the available channels.  Region Technique Frequency Channels Europe    865.6 - 867.6 MHz  4 Americas  FHSS  902.7 - 927.2 MHz 52 Brazil FHSS 915.5 - 927.5 MHz 43 China  FHSS  920.5 - 924.5 MHz 20 Australia  FHSS  920.7 - 925.2 MHz 12 Israel    915.0 - 917.0 MHz  4 Korea  FHSS  917.7 - 920.1 MHz  5 New Zealand  FHSS  917.7 - 920.1 MHz  8 Japan    917.3 - 920.3 MHz  6 Malaysia    919.8 - 922.2 MHz  5 Taiwan  FHSS  922.6 - 927.4 MHz  9 Vietnam    920.7 - 924.3 MHz  7 Table 1: Region specific parameters  4.2 FREQUENCY CHANNEL SELECTION If no frequency hopping is required, you should select an available frequency channel manually. This can be realized as described below. Select an available frequency channel to achieve the best performance and to avoid interference from other readers or equipment.  Use UHFTOOL to setup the frequency channel selection.
  uPASS Access  © Nedap AVI Page 13 of 19  5 READER CONFIGURATION The uPASS reader settings can be configured easily using the UHFTOOL software. Software developers can find the communication protocol description in the firmware manual.  5.1 UHFTOOL SOFTWARE  Figure 5: UHFTOOL software   5.2 SETTINGS Click 'View', 'Show config sidebar' or press F11 to show the configuration sidebar. In the sidebar the configuration categories are shown. Expand or collapse the setting panels by clicking on it.  5.2.1 READ DATA Configure here which tags should be selected, how to access these tags, what data should be read from these tags and if a security check should be performed. By default the reader is configured to select ANY TAG and read its EPC number. Select NEDAP to read only Nedap tags. NEDAP DUAL-ID (introduced in firmware version 2.29) enables the uPASS to search for Nedap vehicle-id tags. When a vehicle-id tag is found, the uPASS searches for driver-id tags.  Example 1: Read only NEDAP UHF tags and use two way authentication:  Figure 6: Read data example 1
  uPASS Access  © Nedap AVI Page 14 of 19  Example 2: Read only NXP UCODE tags (TID starts with E2006) and read 4 words from user memory.  Figure 7: Read data example 2   5.2.2 DECODE NEDAP XS Enable decode Nedap XS formatted tags. Introduced in firmware version 2.54.  Figure 8: Output settings  By default the data on NEDAP XS formatted tags will be transmitted to the TRANSIT compatible processor or the the NEDAP antenna modulation interface. In this case the UPASS will not perform any decoding.  Enable decode Nedap XS when you do not want to use the TRANSIT compatible processor or the antenna modulation interface. The UPASS will decode the NEDAP XS tag data and output its plain tag-number. You can also enable to output or verify the customer code.  The decoded NEDAP XS output number contains: Byte 1: 4E NEDAP UHF Byte 2: <FMT> FMT=01: Nedap XS decoded hex tagno     FMT=02: Nedap XS decoded decimal tagno. Byte 3-4: 00 Unused Byte 5-7: CC CC=Customer code (zero if not transmitted) Byte 8-12: TAGNO TAGNO=Tag number  Examples: NEDAP UHF XS: Output: 4E10 3FFF C415 A87C BD51 8000 NEDAP UHF XS decoded: Output: 4E01 0000 0000 0000 0000 3039 NEDAP UHF XS decoded decimal: Output: 4E02 0000 0000 0000 0001 2345 NEDAP UHF XS decoded + custcode: Output: 4E01 0000 0415 A000 0000 3039 NEDAP UHF XS decoded decimal + custcode: Output: 4E02 0000 0415 A000 0001 2345
  uPASS Access  © Nedap AVI Page 15 of 19  5.2.3 RELAY / TIMING Configure relay output and timing parameters.  Figure 9: Relay / timing settings  Enable 'Automatic relay activation' to activate the relay upon identification. When disabled the relay can only be activated manually.  The 'Relay hold time' setting is the minimum time the relay is activated.  The 'Vehicle hold time' setting is the time, after a vehicle-id tags has been found, for which the reader will search for driver-id tags. This setting is only used in the NEDAP DUAL-ID mode. Introduced in firmware version 2.29.  The (random) RF off time parameter can be used to enable time sharing between multiple readers on the same frequency.   5.2.4 LED CONTROL Only for UPASS ACCESS: setup LED control mode.  Automatic mode: Default the uPASS Access will automatically control the LED. During stand-by the LED will be BLUE and upon identification it will be GREEN. These colors can be changed!   Figure 10: LED control  Remote control: The LED can be controlled remotely by a connected access control system. Digital inputs will determine the color indicated on the LED.
  uPASS Access  © Nedap AVI Page 16 of 19  5.3 EXPERT SETTINGS Click 'Options', 'Usermode', 'Expert' to show additional configuration settings for advanced users.  5.3.1 OUTPUT Configure communication output settings.  Figure 11: Output settings  Select 'Enable serial id-events' to enable the serial output upon identification. Only disable the serial id-events to optimize the identification speed when using the wiegand or magstripe interface or the TRANSIT compatible processor.  When 'Fast repeat serial id-events' is selected (default) the serial output is repeated upon every identification. When this option is disabled, the message is only sent once.  Enable 'Repeat using hold-time interval' to repeat id-events with hold-time interval. The repeating will be enabled for the serial and also for the wiegand or magstripe interface.  'Enable vehicle id-events' allows enabling or disabling the id-event messages for vehicle-ids. This may be useful in combination with the NEDAP DUAL-ID mode and an access control panel that does not support the dual-id feature.  5.3.2 OUTPUT MESSAGE FORMAT Configure output message format.  Figure 12: Output message format  The output message format is configurable:  <prefix> [<tagstatus>] [<epclen>] [<epc>] [<datlen>] [<data>] <suffix> [ CR/LF ]  Note: When the output message format is changed, identified tags may no longer be shown in the UHFTOOL.
  uPASS Access  © Nedap AVI Page 17 of 19  5.3.3 EXTRA OUTPUT Optionally enable wiegand or magstripe output for tags that are not programmed by Nedap in a wiegand, magstripe or nedap-xs format. This feature is introduced in firmware version 2.13 or newer.  'Protocol':  Disabled Do not use the additional output feature.  Wiegand Enable additional wiegand output.  Magstripe Enable additional magstripe output.  'Data source':  EPC number Output the EPC number using the selected protocol.  Custom read data Output the custom data read using the selected protocol.     See for more information about how to setup custom read data chapter 5.2.1.  'Alignment':  Full Use the complete EPC number (or all custom read data).  Left Truncate data. Keep left.  Right Truncate data. Keep right.  'Data length': Data length in bits for wiegand (or in digits for magstripe).  'Offset':    Data offset in bits for wiegand (or in digits for magstripe).  'Add constant': Enable to add a constant to the output before or after the data read from the tag.  Example 1: Output a wiegand 26-bit message with facility code 10:  Figure 13: Additional output example 1 Example 2: Output the 13 rightmost digits from the EPC number using the magstripe interface:  Figure 14: Additional output example 2
  uPASS Access  © Nedap AVI Page 18 of 19  5.3.4 FREQUENCY Here is shown the reader's operating frequency region. Only for systems that do not use frequency hopping (e.g. in Europe): You can select a frequency channel within the available frequency band.  Figure 15: Frequency   5.3.5 READ RANGE Enable the squelch to reduce the read range. This is useful to optimize lane separation. When the squelch is enabled, you can set the squelch level. This level ensures that only tags with a returned signal strength higher then the squelch level are identified. When the squelch is enabled and the returned signal strength is lower then the squelch level, the SQ-ACT LED indicates that the tag is rejected.  Figure 16: Read range
  uPASS Access  © Nedap AVI Page 19 of 19  A TECHNICAL SPECIFICATIONS ITEM SPECIFICATION REMARK Dimensions 150x50x40mm  (5.9 x 1.9 x 1.5 inch)   Weight 0.5 kg  (1.1 lbs)   Enclosure Polycarbonate  (RAL7016)   Chassis material Aluminum (Zamak5)  (RAL9006)   Protection class IP65  (Approx. NEMA4x)   Operational temperature -30 °C … + 60 °C  (-22°F … +140°F)  Relative humidity 10 .. 93 % non condensing   Identification range  Up to 2 meters (Line Off Site) (6 feet) With passive NEDAP UHF tags Power supply 12 … 24VDC ±10% linear power supply   Current consumption  1A @ 12VDC, 0.5A @ 24VDC   Inputs 2 digital input for LED control 1 digital input for buzzer control Active low inputs Tamper indication Yes by tamper switch Dry contact Output Wiegand, magstripe (clock & data)   Cable Fixed shielded cable length of 5 meter (16 feet) included Cable extensions beyond the 5 meter shall ONLY be allowed using shielded cable  Interfaces RS485 and USB USB local service only Air interface ISO18000-6C   Operating frequency Europe: 865 … 868 MHz Americas: 902 … 928 MHz (FHSS) Brazil: 915 … 928 MHz (FHSS) China: 920 … 928 MHz (FHSS) Australia: 920 … 926 MHz (FHSS)   Polarization Horizontal + Vertical Switched every query round  ERP / EIRP < 1 W (30 dBm) ERP (CE)  < 4 W (36 dBm) EIRP (FCC)  Safety EN 60950   Emission EN 302 208-1,-2 v1.3.1 FCC part 15.247 incl. Spread Spectrum Industry Canada RSS210    B PART NUMBERS READERS  NEDAP uPASS Access (EUR) NEDAP uPASS Access (USA) part number:  9958240 part number:  9206663