Nedap N V T325RRFMDID ASSY T325R RF+MD+RFID User Manual Manual

N. V. Nederlandsche Apparatenfabriek NEDAP ASSY T325R RF+MD+RFID Manual

Contents

Manual

Lumen iL33                    ASSY T325R RF IR PRCopyright  © by  N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP.itemdaterevisiondsgndocumentQuick reference :  ASSY T325R RF IR PR: 28 March 2018 1:31 PM: CvdB: A.01: T9224386-45.01: 9224386N.V. Nederlandsche Apparatenfabriek “Nedap” Parallelweg 2, NL-7141 DC Groenlo (The Netherlands)Mail: support-retail@nedap.com1x | ASSY T325R RFdimensions2x | lter 2x | connector RJ454x | insullation ring325mm1'0.80"322mm1'0.68"1534.3mm5'0.41"328.6mm1'0.94"1378.3mm4'6.26" (Customer counter)20mm0.79in231.7mm9.12in97.7mm3.85in60mm2.36in277,5mm10.93inMounting holesUse M10-studsThis  equipment  should  be  installed,  operated,  serviced,  and  repaired  by  qualied  personnel  only.  The  installation  and  interconnection  of  this  equipment  to  facility  wiring  and  other  equipment  must  be  done  by  a  competent,  qualied  craftsperson  who  is  familiar  with  applicable  standards  and  codes  governing  the  installation.  Installation  methods,  practices,  or  procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment.conduit or slit(topview)Warning1
90mm / 3.5”ø 13mm / ø 0.5”2drill the holeØ 13 mm (Ø 0.5in)90 mm (3.5in)3121  Nut M10    (not included in installation set)2  Retainer ring M10  (not included in installation set)3  Nylon insulation ring M10  (included in installation set)always use a nylon insulation ring4231  Drill the hole2  Clean the hole3  Insert Hilti-hit4  Place the nut1remove covers111  Screw M3x102
> 40 cm (15.8 in.)> 20 cm (7.9 in.)distance to a normal door or sliding door (RF)distance to the wall (RF)> 20 cm (7.9in)> 40 cm (15.8in)place near to a wallsocket (RF)3installation orientationThe arrow indicates the  direction to the store exit.Power Inserter (P.I.) always on the right side.
P.I. > network OUTlterscabling11  Ethernet cable2  Renos side1 Filter2  Renos network IN3  Renos network OUT111223power systemPlug the Power Inserter into the socket. 230V115VINPORTANT:Network should be connected in the “network setup”-step of the installation wizard.  Do not connect a network to !Sense before power up!NOTE:Start up takes  approximately 3 minutes.24distance to roller shutter (RF)> 70 cm (27.6 in.)> 70 cm (27.6in)
connecting a laptop to the Renos unitRenos - Service portAttach your laptop to one of the Renos units with a mini USB-USB cable.Open the browser on your laptop and go to:http://192.168.133.1Congure the system using the installation wizard.place covers1  Screw M3x1011place keyswitch11  Remove cover2  Push to remove small metal part 3  Place keyswitch (can be placed on both sides of the antenna)(optional)325
status LEDs Renos11 2 34561  Green  On  There is a Renos unit connected to the OUT port of this unitO  There is no Renos unit connected to the OUT port of this unit2  Blue  Blinking  There is no device connected to the OUT port of this unitOn  There is a Power Inserter connected to the OUT port of this unit3  Red  On  There is an issue with the power supply at the OUT port of this unit (too little current drawn)Blinking  There is an issue with the power supply at the OUT port of this unit (too much current drawn)O  There is no issue with the power supply at the OUT port of this unit4  Yellow  Blinking  The operating system on the Renos unit is runningO  The operating system on the Renos unit is not running5  Green  Blinking  The storage ash on the Renos unit is accessedO  The storage ash on the Renos unit is not accessed6  Green  On  The rmware on the Renos unit is runningO  The rmware on the Renos unit is not (yet) runningRenos1234567891  50Ω  Connect to the 50Ω PCB from the antenna.2  Lights / IR  Connect to the lights and customer counting.3  Add-on  Provide power and synchronisation to add-ons, like the RFID reader.4  Network IN  Connected to the Network OUT of a previous Renos unit or a Power Inserter.5  USB  Connect accessories to Renos, like the RFID reader or USB network adapter.6  Network OUT  Connected to the Network IN of a previous Renos unit or a Power Inserter.  Can also be left unconnected or connected to the customer network.7  Mini USB service port  Connect your laptop to congure the Renos system.8  RS485 connector  Connect to the smart deactivator(s).9  Buzzer connector  Connect to the buzzer.Caution:Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions.3121  Network to Power Inserter IN2  Network to last Renos OUT3  Network to USB-Network adapter (in any gate)network setupWhen on the “network setup” -step of the installation wizard,determine the position of the network and decide how to connect to the !Sense network.6label information11  Pull to see the label information (Two labels at the front side and one at the back side)
7DisclaimerNedap intends to make this manual accurate and complete. However, Nedap does not warrant that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. Nedap disclaims any liability for damage to property or personal injury resulting, in whole or in part, from improper installation, modication, use or misuse of its products. The  information contained in this document is subject to change without notice.FCC and IC Compliance statementThis device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Cet appareil se conforme aux normes CNR 210 exemptés de license du Industry Canada. L’opération est soumis aux deux conditions suivantes:(1) cet appareil ne doit causer aucune interférence, et(2) cet appareil doit accepter n’importe quelle interférence, y inclus interférence qui peut causer uneopération non pas voulu de cet appareil. Les changements ou modications n’ayant pas été expressément approuvés par la partie responsable de laconformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel.FCC and IC Radiation Exposure StatementThis equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and  operated with a minimum distance of 5cm between the radiator and a human body for normal operation. Personel standing permanently next to the antenna frame must keep a distance of at least 30cm. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet équipement est conforme a CNR-102 limites énoncées pour un environne- ment non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 5 cm entre le radiateur et un corps humain pour un fonctionnement normal. Les personnes se tenant en permanence à côté du cadre de l’antenne doivent respecter une distance minimale de 30 cm.This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de Classe B est con-forme à la norme Canadienne ICES-003.FCC Information to the userNote: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are  designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver.NOTE: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To ensure compliance with FCC regulations, use only the shielded interface cables provided with the product, or additional specified components or accessories that can be used with the installation of the product.Declaration of ConformityHereby, De N.V. Nederlandsche Apparatenfabriek “Nedap” declares that the radio equipment type ASSY T325R RF is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://portal.nedapretail.com/User manualThe complete instruction manual can be found at https://portal.nedapretail.com/
8

Navigation menu