Nedap N V SFSB Data Transmission System applied with a Sensor Bridge for lamps User Manual 20110223 Manual Nedap acsens4

N. V. Nederlandsche Apparatenfabriek NEDAP Data Transmission System applied with a Sensor Bridge for lamps 20110223 Manual Nedap acsens4

Contents

User manual 02

  Option for Nedap Luxon wireless light control system         The Sensor Bridge is introduced to add commercially available sensors to the Nedap Luxon light control system.  Once installed the Sensor Bridge is part of the Senzafil Mesh Network.  Sensor data is transferred by this RF network to minimize wiring efforts. Amongst the validated sensors you will find sensors to detect light level, movement or room occupancy. Now it is easy to add sensing capabilities to your Luxon E-series light control system to save more energy.       The Luxon Sensor Bridge  consists two main parts: The dome with the RF electronics and microcontroller The base is used for cable connections for power and sensor.        Figure 1: Luxon Sensor Bridge, version for surface mounting        Powering: The Sensor Bridge is powered from a mains adapter or similar DC-source supplying 12 to 24V. This voltage is also available for the sensor, so you can choose the supply voltage depending on the voltage needed for the sensor to be used. Power connection via either a standard DC-plug or screw terminals.
  Option for Nedap Luxon wireless light control system   LIGHT SENSORMOVEMENT SENSORMAINS ADAPTERNEDAP RF SENSOR BRIDGEFigure 2: Wiring overview for the Luxon Sensor Bridge  Compatible sensors:  Many sensor types can be used: - Switches; - 1 to 10V dimmers (resistive and electronic potentiometers); - Light sensors;  - Sensors for detection of movement and / or room occupancy.  To select an appropriate sensor that fits your application and your preferences, please use the listing available on our web site www.nedaplightcontrols.com.           The Sensor Bridge may only be installed and configured by qualified and trained personnel. For an installation example please see figure 3 below.  The Sensor Bridge can be ordered for surface mounting or for recessed mounting; the dome should always point downwards if mounted at approximately the same height as the Senzafil lamp drivers. For recessed mounting, both clamps can be used to secure the unit to a ceiling element. After finishing the connections, the dome shall be secured to the base using four torx screws. After powering the Sensor Bridge it shall be configured using the Senzafil Configuration Tool. From the pick list you can easily select the used sensor with its characteristics.
  Option for Nedap Luxon wireless light control system    SKYLIGHTSKYLIGHTNEDAP LUXON LIGHT CONTROLLERSENSOR DATA FLOW IN SENZAFIL  RF MESH NETWORKNEDAP LUXON SENSOR BRIDGE WITH LIGHT SENSORHID LAMPS WITH NEDAP LAMP BALLAST  Figure 3: Installation example for the Sensor Bridge with HID lamps controlled via the            Wireless Senzafil Mesh Network in a building with skylights.
  Option for Nedap Luxon wireless light control system                                                       Luxon Sensor Bridge for surface mounting: 8018669, ordering nr. 9949348 Luxon Sensor Bridge for recessed mounting: 8019037, ordering nr. 9949356  DescriptionDescriptionDescriptionDescription     DetailsDetailsDetailsDetails    Supply Voltage     10 to 28VDC Supply current    Sensor Bridge: max 100mA, standby < 20mA External sensor: max 200mA Mains adapter specification 12V / 4W or 24V / 6W Dimensions  Diameter: 130 mm,  Height 70 mm Weight     0.23kg including cable glands Enclosure protection  IP67 (the enIP67 (the enIP67 (the enIP67 (the enclosed cable glands must be used properly)closed cable glands must be used properly)closed cable glands must be used properly)closed cable glands must be used properly)    Housing colors  Base: light gray, top: milky grey-white Connector  power:  standard DC jack with 2.0 mm centre pin or  2 screw terminals 30-18 AWG, or 0.25 to 1.5 sq.mm.  sensor: 3 screw terminals 30-18 AWG,  or 0.25 to 1.5 sq.mm. Safety    United States and Canada   United States and Canada   United States and Canada   United States and Canada       An UL listed An UL listed An UL listed An UL listed mains adapter mains adapter mains adapter mains adapter shallshallshallshall    be usedbe usedbe usedbe used    that meets the NEC Class 2 requirementsthat meets the NEC Class 2 requirementsthat meets the NEC Class 2 requirementsthat meets the NEC Class 2 requirements    The Sensor bridge is designed to meet UL6The Sensor bridge is designed to meet UL6The Sensor bridge is designed to meet UL6The Sensor bridge is designed to meet UL619191919     EuropeEuropeEuropeEurope    AnAnAnAn    EN60950 compliant mains adapter must be usedEN60950 compliant mains adapter must be usedEN60950 compliant mains adapter must be usedEN60950 compliant mains adapter must be used        EMC    United States aUnited States aUnited States aUnited States and Canada   nd Canada   nd Canada   nd Canada       FCC47 part FCC47 part FCC47 part FCC47 part 15 15 15 15          EuropeEuropeEuropeEurope    ENENENEN301301301301    489489489489----1 and 4891 and 4891 and 4891 and 489----3333    EN300 328EN300 328EN300 328EN300 328              Temperature  Operating 0 Operating 0 Operating 0 Operating 0 ––––    60°C,  Storage 60°C,  Storage 60°C,  Storage 60°C,  Storage ----20 to 80°C20 to 80°C20 to 80°C20 to 80°C    Humidity  25 to 95 % RH. Condensing and icing max 5% of time25 to 95 % RH. Condensing and icing max 5% of time25 to 95 % RH. Condensing and icing max 5% of time25 to 95 % RH. Condensing and icing max 5% of time
  Option for Nedap Luxon wireless light control system        FFFFCC DeclarationsCC DeclarationsCC DeclarationsCC Declarations    Compliance statement (part 15.19) Compliance statement (part 15.19) Compliance statement (part 15.19) Compliance statement (part 15.19)     This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.     Déclaration ConformitDéclaration ConformitDéclaration ConformitDéclaration Conformitéééé    Cet appareil se conforme aux normes RSS exemptés de license du Industry Canada.  L'opération est soumis aux deux conditions suivantes  (1) cet appareil ne doit causer aucune interférence, et  (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de cet appareil.     Warning (part 15.21)Warning (part 15.21)Warning (part 15.21)Warning (part 15.21)    Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  RF ERF ERF ERF Exposure (OET Bulletin 65)xposure (OET Bulletin 65)xposure (OET Bulletin 65)xposure (OET Bulletin 65)    To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations where there is at least 20cm separation distance between the antenna and all persons.                                     Version:   0.4 Date:  20110223