Date : 23 February 2012      Version 5 This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no licence under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.   © Nedap N.V., IDEAS  P.O. Box 103 NL-7140 AC GROENLO The Netherlands       Page 1 of 4 Part.no.: 5265800 Invexs 170 readers Mifare Nedap dual technology readers  GENERAL The  Invexs  170  reader  series  is  capable  of  reading (simultaneously) Nedap, Mifare and DESFire credentials due to its  dual  reader  technology.  The  Invexs  can  read  Mifare, DESFire and Nedap cards, and is equipped with keypad and / or a display. The  Invexs  output  can  be  set  to  either  Wiegand,  XS  RF modulation or  RS485 protocol (plain or encrypted) Functionality and output are determined by the configuration of the  Invexs  reader.  The  configuration  is  defined  using  the programm AEreco, and deployed by the configuration card or via  AEmon.  (More  information  about  configurations  can  be found in ConvexsInvexs_InstallGuide_E.) Three LED’s (red, green, blue) and beeper are included (display version has no LED). Ciphers of the keypad versions light up after activation, so when not active the ciphers are not visible. Back panel is available in two colours, black and white (e.g. MNK170B, MNK170W)   DIMENSIONS                      MOUNTING PROCEDURE INVEXS For mounting the Invexs, the back plane must be placed on the wall first. For removing the back plane from the Invexs, unscrew the two screws (1) at the  bottom of the  Invexs and push  the  front  cover  up (2).  Mount the  back plane using the 4 holes. Connections must be made on the connector on the backside of the front.  After making the connections, replace the front and tighten up the two screws at the bottom of the Invexs. ®  Installation sheet 75.2 52 40 6.8 4.8 20.3 1208 40 170.5 24.5 1.5 0.5 Dimensions: 171 x 75 x 25 mm.  4 mounting holes available at 52 x 120 mm  Cable outlet: 40 x 40 mm  1 2 3 4 5 6 7 8 9 C 0 E Un screw Push up 1 2 1 2 3 4 5 6 7 8 9 C 0 E 1 2 3 4 5 6 7 8 9 C 0 E
Invexs 170 readers © Nedap N.V.                   Invexs 170 readers   Installation sheetPage 2 of 4       R GND UL*/NA* / BEEP CONNECTIONS Invexs is not hot-swappable, so when making or changing connections power must be switched Off.            Remark:  Cable shield must be connected to Power GND of Convexs (A2) and GND of external device (or metal case).  If connected to a 120kHz RF device (AEOS Nedap reader AEpack or XS device) the power is supplied via the Convexs adapters (AX1014 for AEpacks, AB350 for XS devices). Existing antenna cabling can then be reused for connecting the ConveXS.  UL*,NA* and BEEP are Open Collector to GND. If the Convexs adapters are used, the original UL and NA signals are converted to the UL* and NA*.   LED INDICATORS INSIDE There are two LED’s available: Blue for Status (of application), Green for Identification (both visible through two small holes at the back side)           LED INDICATORS FRONT At the front a three colour LED is positioned at the middle of the Invexs  Depending of the used configuration the function of these LED’s can differ:  Green LED:    Card is been authorised (UL led)   Red LED:     Card is not authorised (NA led), controller is stand-by  Blue LED: Blinks fast:       No configuration is availabele at this Invexs (present Configuration  card or load Configuration first). Continuously ON:  Determined by configuration: E.g. Reader stand-by. (Blue LED is activated if UL is OFF and NA is more than 1 sec OFF)  Remark: Function of LED’s and Beeper is controlled by used application settings of Invexs. Green and Red LED  can  be  controlled  by  hardware  signals  (Connector  8  and  10)  or  RS485NR,  Blue  LED indirectly by UL and NA, if this setting is activated (configuration). Beeper can be controlled by hardware signal (Connector 7), RS485NR or software (configuration). Invexs Function 1 Power / XSMOD Power in (10-30VDC) / XS modulator (120kHz) 2 POWER GND/Shield Power Ground 3 A (-) RS485 4 B (+) RS485 5 D0 Wiegand Data 0 6 D1 Wiegand Data 1 7 BEEP Beep input 8 UL* UL led input 9 GND Led Common Ground 10 NA* NA led input  1 10 1 10 51 61 Invexs  with display Invexs  without display ID (green) Blinking Card detected  ST: STATUS (blue) Slow blinking  Application running (operating) Fast blinking Downloading or error during loading 2 short flashes Application present but not active 3 short flashes No application present
Invexs 170 readers © Nedap N.V.                   Invexs 170 readers   Installation sheetPage 3 of 4 FIRMWARE Pay attention that the firmware loaded in the Invexs together with the Invexs type and configuration determines functionality and protocols.  For the Invexs with screen contact Nedap. Default (from factory) the Invexs handles the credentials on several ways simultaneously:  XS cards as:         RS485NR, RF badge  Mifare cards (CSN) as:  RS485NR, RF data   SYSTEM CONFIGURATIONS (how to connect Invexs readers)                     Remark: Configurations can be determined by using the configuration card.  Attention: Check the ConvexsInvexs_InstallationGuide chapter 8 (Available reader Firmware) for the compatibility for the used readers.   TAMPER SWITCH This tamper switch is an optical device, which is triggered by the amount of light. Depending on the applied configuration the result of activating the tamper switch can differ.   BEEPER INDICATIONS Beeper is also used for indication of loading the configuration:  High  sound  beep  (‘happy  sound’):  Configuration  is  loaded  correct,  second  high  sound  beep indicates that this configuration can be used with this Invexs  Low  sound  beep  (‘unhappy  sound’):  Configuration  is  not  correct  loaded  or  no  configuration available at startup         Invexs uses existing antenna cabling  (Coax + 3*0,25qmm for LED’s). On each AEpack-RF interface an AX1014  must be added.  Connections: see AX1014 RF interface AEpacks Accessor III / SimpleXS AX1014 AX1014 AX1014 AX1014 AX1014 AB350 RF interface XS systems Invexs uses existing antenna cabling  (Coax + 3*0,25qmm for LED’s). On each XS reader-RF interface an AB350 must be added.    Connections: see AB350 To APx003 readers with RS485 special encrypted protocol. (LED’s, Beeper, Keys and Display are controlled over the RS485 communication) AEOS RS485 interface - Third party systems - AEOS Wiegand Wiegand interface Wiegand output connected to Third party systems (or to AEOS Wiegand interfaces). LED’s andBeeper are controlled by hard wiring. (PINcode possible) 1 2 3 4 5 6 7 8 9 C 0 E 1 2 3 4 5 6 7 8 9 C 0 E
..--. ~ c:=Ii::3FI®_R-=In::,v..:.;e;;.:x""s:...1"-7'-'O'-r::..;:e:..::a:;.=d;.::.er=sSPECIFICATIONS Invexs 170 Product numbers see table below: For Screen / dis la contact NedaColour Reader Ke ad Screen / Dis laM170 Black M170B 9833900 MK170B 9834230 MKS I 70B 9939822Mifare Wbite MI70W 9832750 MK170W 9832920 MKS 170W 9833390MD170 Black MD170B 9834400 MDK170B 9834680 MDKSI70B 9939849MifareDESFrr~e __ _+~W~h~it~e--~MD~I~7~OW~--~9~83~4~3~7~0_+~MD~K~17~0~W~~~9~8~3~45~4~0~~M~D~K~S~I~70~W~~~98~9~1~8~20~MN170 Black MNI70B 9834060 MNK170B 9833730 MNKS170B 9833870NtifareNedap ~W~h~it~e--~MN~I~7~OW__ --~9~83~2~8~9~0-+~~~~17~O_VV__ ~~9~8~3~30~8~0~~M--N-K~S~17-0~W--~~98~3~3~4~20~MND170 Black MND170B 9899570 MNDK170B 9938761 MNDKS170B 9938796Ntifare DESFire Ne=-=d=a!:..p_L~VVh~it~e__ L.:.:MND=::..:1~7..::0.:.:vv'---'-i..:::9~89::..:9:...:4:.:::3~0_L~MND:::::...:::::;K:=.17:..::0:...:w-'---'-i~9:..::9:.:::3:::.87.:..:5::::3:....J.-'MND=.:=K::::Sc:.l.:...:70,,-,W,,----,---,,-99::..:3:.::8:..:.7::::88,,----,Dimensions: 171 x 75 x25 mmPower Supply:Weight:±200 grPower consumption: 70mA@12VDC, 35mA@24VDCM.NKS: 140mA@12VDC, 70mA@24VDCTemperature: Operating: 0 - 55°C, Storage: -30 - 65 °C Relative humidity: 10 - 93% non condensingYesRS485 (Encrypted AEOS protocol to APx003, (firmware APx003rs485NR). RS485 plainWiegand Data 0 and Data I (protocol depending of configuration)RF Modulator (120 kHz for AXI014 or AB350)Beeper (Beep ON / OFF, controlled by application) Open collector to GND, max 20mAUL*led Open collector to GND, max 20mANA*led Open collector to GND, max 20mAUL (green) NA (red) ,MD (blue) (if available)Antenna 1: 120 kHz, Nedap XS compatible (PM and AM cards).Antenna 2: 13,56 MHz, Mifare compatibleDetection distance UniXS card: 15 cmDetection distance Mifare card: 5 emMifare EY1 card: I emIOVDC - 30VDCEnvironment:Tamper switch:Communication:Inputs:Indicators:Antennas (internal):CABLE SPECIFICATIONSRS485: 2 x 2 x 0,25mm' shielded, max cable length: 1000 meter, cable capacity <= 100pF/meterULlGND/NA: 3 x 0,25mrn', max cable length: 50 meterXS MOD / GND: Coax RG58U, max cable length: 50 meterOr 5 x 0,25mm' shielded, max cable length: 50 meter, cable capacity <= 100pF/meterWiegand: 4 x 0,25mm' shielded (excl. LED's), max cable length: ISO meter, depending on receiving device.MORE INFORMATION: For more detailed information contact your local Nedap supplier or check the internet site.FCC ID: CGDINVEXS170                  and       IC: 1444A-INVEXS170 Compliance statements (part15.19) This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis  aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et  (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération  non pas voulu de cet appareil. Warning (part15.21) Changes or modifications not expressly approved by party responsible for compliance could void the user’s  authority to operate the equipment.

Navigation menu