NESSLAB NL-RF2200 RFID Reader User Manual

NESSLAB RFID Reader

User Manual

           NL-RF2200 UHF RFID Reader  Hardware User's Manual   2014         www.nesslab.com
  RFID Reader Hardware User Guide 2 Contents  1. Introduction 1.1 Overview 1.2 Composition 1.3 Reader Configuration 1.4 Reader Installation 1.5 Reader Physical Size 1.6 Specification 1.7 RS-232 & GPIO Interface  2. Antenna    2.1 Scope 2.2 Composition and Materials. 2.3 Mechanical Dimensions. 2.4 Electrical specifications. 3. FCC Information to User 4. WARNING TO USER 5. Reader,  Anrenna Troubleshoot Guide
  RFID Reader Hardware User Guide 3 1. INTRODUCTION   1.1 Overview  NL-RF2200 is a Fixed Type 900MHz RFID Reader, enables user to use RS232 or Ethernet Interface for efficient and convenient use. It is suitable for various applications such as Logistic, Asset tracking, Stock management, Parking lot management, Healthcare, Security, Transportation and bank system. User can use up to 4 antennas  per one reader, perfect for wide range reading application than longer distance reading application.   1.2 Composition  ◈ System configuration  ◈ RS-232  LAN  PC  Network  Tag #1  Tag #2  Tag #N Reader main body DC5V/5A adapter  LAN Cable Antenna (Option) Antenna cable  (Option)  Instruction
  RFID Reader Hardware User Guide 4 1.3 Reader Configuration                     ANT1 / ANT2 / ANT3 / ANT4 : Connecting  antenna  up  to  4  using cable. DC5V : Using DC5V/3A adapter to supply power to RFID reader.  LED : Yellow  – Ethernet  cable connection indicator Green  – Recognition of Ethernet cable and Tag  Reading indicator          Red  – Power indicator LAN : To connect to PC or other device for data transmission or software upgrade.    RS-232 : To connect to PC or other device for data transmission or software upgrade.
  RFID Reader Hardware User Guide 5 1.4 Reader Installation                         ◈ How to install antenna correctly ◈ 1. Avoid metal material the front side of antenna in 2M due to cause of low performance. 2. Make the antenna stay still.   3. Antenna Cable per each ports should be not tangled and tied up. ◈ How to install or connect reader with antenna  ◈ ◈  When  connection  Antenna  cable for each port, connect SMA Type connecter to  main  body and  N Type connecter to Antenna. ◈  Connect RS-232 cable for serial communication checking with right direction of the connecter. ◈  Connect  adapter  with  power supply  code  then  connect  adapter jack to main body.  ◈ In case of use of multi connect or extension cable, avoid to exceed voltage(rated current) over than mentioned.   1. Make the reader stay still. 2. Connect each cable in the package. ◈ Connect LAN cable to main body LAN port for Ethernet communication.
  RFID Reader Hardware User Guide 6 1.5 Reader Physical Size ☞ unit: mm
  RFID Reader Hardware User Guide 7 1.6 Specification                ITEM SPECIFICATION Model Number NL-RF2200 Operating Frequency 902.75 MHz ~ 927.25 MHz RF Output Port 4  Hopping Channels 50 Channel Spacing 500 KHz Channel Dwell Time  < 0.4 seconds Modulation Phase Reversal-Amplitude Shift Keying (PR-ASK) RF Transmitter < 1W (+30 dBm) Communication Interface RS-232 (DB-9F), TCP/IP (RJ-45) GPIO Support  2-Input / 2-Output  Dimensions 107 x 98 x 32 mm Weight 430g Operating Temperature  -10 ~ + 50 ℃ LED Indicators Link, ACT, Power Input Power  DC 5.0V Power Consumption  12W Protocols Support  ISO 18000-6 Type C/ EPC Class1-Gen2 Software Support  Reader Manager (API) Compliance Certifications  -
  RFID Reader Hardware User Guide 8   1.7  RS-232 & GPIO Interface                                      Pin NO.  RS-232 Interface  GPIO  Interface (Option) 1  Not Connected   +3.3V Output 2  Transmit Data  Not Connected 3  Receive Data  Not Connected 4  Not Connected  I nput1 5  Ground Ground 6  Not Connected  Output1 7  Not Connected  Output2 8  Not Connected  I nput2 9  Not Connected  +5V or +12V Output
  RFID Reader Hardware User Guide 9   2. Antenna  2.1 Scope  This specification covers the characteristics of the ceramic patch antenna element for the ISM band   2.2 Composition and Materials.  1. Substrate             :  Air & Insulator 2. Electrode Plating  : Copper & Aluninum 3. Terminal pin         :  Heat-resisting ABS   2.3 Mechanical Dimensions.  ☞ unit: mm
  RFID Reader Hardware User Guide 10   2.4. Electrical specifications.                                  NO.  Parameters  Spec.  Typical value  Unit  Remark 1 Center Frequency  919    MHz   2  Band Width @ - 10 dB R.L.  60 min.  80  MHz   3  VSWR  2.0 : 1 max.  1.1 : 1  Ratio  @919 MHz 4  Gain @ Zenith  5.0 min.  5.0~6.0  dBiL  @919 MHz 5  Axial Ratio  3.0   1.5~2.0  dB  @919 MHz 6 Impedance    50 Ohms  7 Polarization  RHCP
  RFID Reader Hardware User Guide 11   3. FCC Information to User  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not  installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of FCC Rules.  Operation is subject to the following two conditions:  (1) the device may not cause interference, and    (2) the device must accept any interference, including interference that may cause  undesired operation of this device.  4. WARNING TO USER  - Change or modifications not expressly approved the manufacturer can void the     user's authority to operate this equipment. - This equipment must not be co-located or operated in conjunction with any other  antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in  Supplement C to OET65. This equipment must be installed and operated with at least  20cm and more between the radiator and person’s body (excluding extremities: hands,  wrists, feet and ankles).
  RFID Reader Hardware User Guide 12  5.Reader,  Anrenna Troubleshoot Guide  5.1 Fixed Reader and Antenna Troubleshoot      1. Confirm the demage of the out case and the inundation. 1) check the external connector .    2) check the inundation .(Check the clearance of the reader)  2. Confirm the reader setup program. 1) The reader setup is the execution of the reader manager program           3. Confirm the error of the power. 1) Check  the adaptor  (The output power is  5v dc)
  RFID Reader Hardware User Guide 13  2) Check the connection of  the ac adapter to the reader.            3) Confirm the red LED of  the reader          4) If the red LED is off, the power is not supplied.   Check the connection of the ac power cord.   Change the output of the ac/dc adapter.    4. Confirm the LAN  connection. 1) Confim the yellow LED.
  RFID Reader Hardware User Guide 14  2) If  the yellow LED is off ,  the ethernet is not connected to the host  PC.           3) Confirm the reader IP (The default IP of the reader is 192.168.10.91)             4) Confirm the host PC setting ( disable the other connection )
  RFID Reader Hardware User Guide 15   5. check the configuration of the reader. 1) check the antenna port at the reader manager configuration.   2) check the antenna power level and the antenna register. The antenna power level is 15dBm ~ 30dBm. The antenna register is 1000000                   6. Check the antenna  connection and the antenna opetration. 1) Check the antenna setting
  RFID Reader Hardware User Guide 16  2) Check the antenna cable damages                                                       3) Check the antenna damages.                                 7. Then ask the A/S center(+82-31-206-1774), if the reader is out of order after all that

Navigation menu