APPLICANT: MOTOROLA  EQUIPMENT TYPE: ABZ89FC5798-P EXHIBIT 8  INSTRUCTION MANUALS  Excerpts from the instruction and service manuals for this base radio are available and have been included as part of the filing package in the form of an electronic pdf document.  Upon request, published and/or printed manuals will be sent to the commission and/or telecommunication certification body (TCB).  All of the descriptions and schematics included this filing package are up to date.
APPLICANT:  MOTOROLA  INC.                                                                            EQUIPMENT TYPE:  ABZ89FC5798-PEXHIBIT 9TUNE-UP PROCEDUREThere is no field tune-up procedure.  All adjustments are software controlled and are pre-set at the factory.  Certainstation operating parameters can be changed via man-machine interface (MMI) commands, within predeterminedlimits.  Examples include transmit / receiver operating frequencies and power level.
Technical ManualiDENEnhanced Base Trans-ceiver System (EBTS)Volume 2 of 3Base Radios  68P80801E35-E16-June-06 RF SUB-SYSTEM
Notice to UsersNo part of this publication, or any software included with it, may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, including but not limited to, photocopying, electronic, mechanical, recording or otherwise, without the express prior written permission of the copyright holder. Motorola, Inc. provides this document “AS IS” without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Motorola reserves the rights to make changes or improvements in the equipment, software, or specifications described in this document at any time without notice. These changes will be incorporated in new releases of this document.Computer Software CopyrightsThe Motorola and 3rd Party supplied Software (“SW”) products described in this instruction manual may include copyrighted Motorola and other 3rd Party supplied computer programs stored in semiconductor memories or other media. Laws in the United States and other countries preserve for Motorola and other 3rd Party supplied SW certain exclusive rights for copyrighted computer programs, including the exclusive right to copy or reproduce in any form of the copyrighted computer program. Accordingly, any copyrighted Motorola or other 3rd Party supplied SW computer programs contained in the Motorola products described in this instruction manual may not be copied, reverse engineered, or reproduced in any manner without the express prior written permission of Motorola or the 3rd Party SW supplier. Furthermore, the purchase of Motorola products shall not be deemed to grant, either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola or other 3rd Party supplied SW, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product. Use and Disclosure RestrictionsThe software described in this document is the property of Motorola, Inc. It is furnished under a duly executed license agreement and may be used and/or disclosed only in accordance with the terms of the said agreement.The software and documentation contained in this publication are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without the express prior written permission of Motorola, Inc.TrademarksMOTOROLA, the Stylized M Logo, iDEN, and Message Mail are trademarks or registered trademarks of Motorola, Inc. in the United States and other countries.All other product or services mentioned in this document are identified by the trademarks or service marks of their respective companies or organizations, and Motorola, Inc. disclaims any responsibility for specifying their ownership. Any such marks are used in an editorial manner, to the benefit of the owner, with no intention of infringement.© 2006 - Motorola, Inc.   All Rights Reserved REV 12/15/06Contact InformationMotorola, Inc.Networks business1501 Shure Dr.Arlington Heights, IL 60004U.S.ASPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.While reasonable efforts have been made to assure the accuracy of this document, this document may contain technical or typographical errors or omissions. Motorola, Inc. and its subsidiaries and affiliates disclaim responsibility for any labor, materials, or costs incurred by any person or party as a result of using this document. Motorola, Inc., any of its subsidiaries or affiliates shall not be liable for any damages (including, but not limited to, consequential, indirect, incidental, or special damages or loss of profits or data) even if they were foreseeable and Motorola has been informed of their potential occurrence, arising out of or in connection with this document or its use. Motorola, Inc. reserves the right to make changes without notice to any products or services described herein and reserves the right to make changes from time to time in content of this document and substitute the new document therefor, with no obligation to notify any person or party of such changes or substitutions.
Enhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E -vAbout This VolumeVolume 2 of the Enhanced Base Transceiver System (EBTS) manual, Base Radios, provides the experienced service technician with an overview of the EBTS operation and functions, and contains information regarding the 800 MHz, 900 MHz, 800/900 MHz QUAD Channel, and 800/900 MHz QUAD+2 Channel base radios.The EBTS has three major components:■Generation 3 Site Controller (Gen 3 SC) or integrated Site Controller (iSC)■Base Radios (BRs)■RF Distribution System (RFDS)Installation and testing is described in Volume 1, System Installation and Testing, and RFDS are described in Volume 3, RF Distribution Systems (RFDS). Detailed information about the Gen 3 SC is contained in the Gen 3 SC Supplement Manual, 68P80801E30. Detailed information about the iSC is contained in the iSC Supplement Manual, 68P81098E05The information in this manual is current as of the printing date. If changes to this manual occur after the printing date, they will be documented and issued as Schaumburg Manual Revisions (SMRs).
About This Volume Volume 2Audience ProfileEnhanced Base Transceiver System (EBTS)-vi 68P80801E35-E 16-June-06Audience Profile 0The target audience of this document includes field service technicians responsible for installing, maintaining, and troubleshooting the EBTS. In keeping with Motorola’s field replaceable unit (FRU) philosophy, this manual provides sufficient functional information to the FRU level. Please refer to the appropriate section of this manual for removal and replacement instructions.
Volume 2 About This VolumeRelated ManualsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E -viiRelated Manuals 0The following publications may be required to supplement the information contained in this manual:Number Title Description68P80801E30 Generation 3 Site Controller(Gen 3 SC) - System ManualProvides detailed information about the Gen 3 SC including a description of major subsystems, components, installation, testing, troubleshooting, and other information68P81098E05 Integrated Site Controller (iSC)System ManualProvides detailed information about the iSC including a description of major subsystems, components, installation, testing, troubleshooting, and other information.68P81089E50 Motorola Standards and Guidelines for Communications SitesA useful reference for the installation of fixed network equipment. This manual provides guidelines and procedures to ensure the quality of Motorola radio equipment installation, integration, optimization, and maintenance. Field service personnel should be familiar with the guidelines and procedures contained in this publication.6881131E90 iDEN Guide to Motorola Acronyms and TermsA useful reference for Motorola used Acronyms and Terms.
About This Volume Volume 2Customer Network Resolution CenterEnhanced Base Transceiver System (EBTS)-viii 68P80801E35-E 16-June-06Customer Network Resolution Center 0The Customer Network Resolution Center (CNRC) is a integral part of the network support process.Before performing any major changes or optimization on the system, please contact the CNRC. Notify the CNRC with the nature of the change and the schedule for the change. This will allow CNRC to have the correct technical support engineers on call in case they are needed.Please refer to the Customer Guide to iDEN Customer Network Resolution Center (CNRC) (WP2000-003) for more information regarding:■Procedures for calling CNRC■Classification of trouble tickets■The escalation processesThis document is located on the iDEN extranet website at the URL:http://mynetworksupport.motorola.com The CNRC can be contacted at the following telephone numbers:Domestic(800) 499-6477InternationalBrazil: 0-800-891-5895Mexico: 001-800-499-6477Peru: 0-800-52-121Colombia: 01-800-700-1614Argentina: 0-800-666-1559China: 10-800-130-0617Singapore: 800-1301-285Philippines: 1-800-1-116-0119Korea: 00-308-13-1358All other International locations:1+847-704-9800
Volume 2 About This VolumeManuals On-lineEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E -ixManuals On-line 0This manual is available on the World Wide Web at mynetworksupport, the iDEN customer site. This site was created to provide secure access to critical iDEN Infrastructure information.  This web site features a library of iDEN Infrastructure technical documentation such as bulletins, system release documents and product manuals.The documents are located on the secured extranet website at the URL:https://mynetworksupport.motorola.com For information on obtaining an account on this site, go to:https://membership.motorola.com/motorola
About This Volume Volume 2Reporting Manual ErrorsEnhanced Base Transceiver System (EBTS)-x 68P80801E35-E 16-June-06Reporting Manual Errors 0If you locate an error or identify a deficiency in this manual, please take the time to contact us at the following email address:tpid23@motorola.comBe sure to include your name, fax or phone number, the complete manual title and part number, the page number where the error is located, and any comments you may have regarding what you have found.Thank you for your time. We appreciate any comments from the users of our manuals.
Volume 2 About This VolumeConventionsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E -xiConventions 0Software ■submenu commands—Table > Table Designer■new terms—mobile subscriber■keystrokes—Ctrl+Alt+Delete, Return■mouse clicks—click, double-click■user input—Type delete■screen output—DAP is starting....Hardware ■CD-ROMSafety This manual contains safety notices (alerts). Alerts are based on the standards that apply to graphics on Motorola equipment. Specific procedural notices are stated in the procedures as required and have specific visual representations. The representations are:Ì!DANGERINDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN DEATH OR SERIOUS INJURY.Ì!WARNINGIndicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.Ì!CAUTIONIndicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.CAUTIONWithout the alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.Important Indicates an item of the essence of a topic that is indispensable. Note Indicates something of notable worth or consequence.
About This Volume Volume 2Product Specific Safety NoticesEnhanced Base Transceiver System (EBTS)-xii 68P80801E35-E 16-June-06Product Specific Safety Notices 0The specific procedural safety precautions are stated in the procedures and are also listed here.
Volume 2 About This VolumeGeneral SafetyEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E -xiiiGeneral Safety 0Important Remember Safety depends on you!!General safety precautions must be observed during all phases of operation, service, and repair of the equipment described in this manual. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the equipment.You must heed the safety precautions and warnings listed in the product manuals for your equipment.  Any individual using or maintaining the product(s), should follow these warnings and all other safety precautions necessary for the safe operation of the equipment in your operating environment.  Motorola, Inc. assumes no liability for failure to comply with these requirements.Keep Away From Live CircuitsÌ!DANGERHAZARDOUS VOLTAGE, CURRENT, AND ENERGY LEVELS ARE PRESENT IN THIS PRODUCT. POWER SWITCH TERMINALS CAN HAVE HAZARDOUS VOLTAGES PRESENT EVEN WHEN THE POWER SWITCH IS OFF. DO NOT OPERATE THE SYSTEM WITH THE COVER REMOVED. ALWAYS REPLACE THE COVER BEFORE TURNING ON THE SYSTEM.Operating personnel must:■Not remove equipment covers. Only Factory Authorized Service Personnel or other qualified maintenance personnel may remove equipment covers for internal subassembly, or component replacement, or any internal adjustment.■Not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed.■Always disconnect power and discharge circuits before touching them.
About This Volume Volume 2General SafetyEnhanced Base Transceiver System (EBTS)-xiv 68P80801E35-E 16-June-06Ground the EquipmentTo minimize shock hazard, the equipment chassis and enclosure must be connected to an electrical earth ground. The power cable must be either plugged into an approved three-contact electrical outlet or used with a three-contact to two-contact adapter. The three-contact to two-contact adapter must have the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable must meet International Electrotechnical Commission (IEC) safety standards.Electro-Static DischargeMotorola strongly recommends that you use an anti-static wrist strap and a conductive foam pad when installing or upgrading the system. Electronic components, such as disk drives, computer boards, and memory modules, can be extremely sensitive to Electro-Static Discharge (ESD). After removing the component from the system or its protective wrapper, place the component flat on a grounded, static-free surface, and in the case of a board, component-side up. Do not slide the component over any surface. If an ESD station is not available, always wear an anti-static wrist strap that is attached to an unpainted metal part of the system chassis. This will greatly reduce the potential for ESD damage.Do Not Operate In An Explosive AtmosphereDo not operate the equipment in the presence of flammable gases or fumes. Operation of any electrical equipment in such an environment constitutes a definite safety hazard.Do Not Service Or Adjust AloneDo not attempt internal service or adjustment, unless another person, capable of rendering first aid and resuscitation, is present.Use Caution When Exposing Or Handling a Cathode-Ray TubeBreakage of the Cathode-Ray Tube (CRT) causes a high-velocity scattering of glass fragments (implosion). To prevent CRT implosion, avoid rough handling or jarring of the equipment. The CRT should be handled only by qualified maintenance personnel, using approved safety mask and gloves.Do Not Substitute Parts Or Modify EquipmentBecause of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification of equipment. Contact Motorola Warranty and Repair for service and repair to ensure that safety features are maintained.
Installation Volume 1IntroductionEnhanced Base Transceiver System (EBTS)3-2 68P80801E35-E 16-June-06Introduction 3The procedures described in this section assume the field technician or installer has knowledge of the installation techniques contained in the Quality Standards Fixed Network Equipment - Installation Manual (Motorola Standards and Guidelines for Communication Sites "R56" (68P81089E50)). Note Prior to performing the installation procedures, prepare the site with all associated antennas, phone lines, and other related site equipment. This information is covered in the Pre-Installation section of this manual.General Safety PrecautionsImportant Compliance with FCC guidelines for human exposure to Electromagnetic Energy (EME) at Transmitter Antenna sites generally requires that Personnel working at a site shall be aware of the potential for exposure to EME and can exercise control of exposure by appropriate means, such as adhering to warning sign instructions, using standard operating procedures (work practices), wearing personal protective equipment, or limiting the duration of exposure. For more details and specific guidelines, see Appendix A of the R56 Standards and Guidelines for Communications Sites (68P81089E50) manual.Observe the following general safety precautions during all phases of operation, service and repair of the equipment described in this manual. Follow the safety precautions listed below and all other warnings and cautions necessary for the safe operation of all equipment. o Refer to the appropriate section of the product service manual for additional pertinent safety infor-mation. o Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modifications of equipment.The installation process requires preparation and knowledge of the site before installation begins. Review installation procedures and precautions in the Motorola Standards and Guidelines for Communication Sites "R56" (68P81089E50) before performing any site or component installation.Always follow all applicable safety procedures, such as Occupational Safety and Health Administration (OSHA) requirements, National Electrical Code (NEC) requirements, local code requirements, safe working practices, and good judgment must be used by personnel. General safety precautions include the following:■Read and follow all warning notices and instructions marked on the product or included in this manual before installing, servicing, or operating the equipment.■Retain these safety instructions for future reference.
Volume 1 InstallationIntroductionEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 3-3■If troubleshooting the equipment while power is on, be aware of the live circuits.■Do not operate the radio transmitters unless all RF connectors are secure and all connectors are properly terminated.■All equipment must be properly grounded in accordance with the Motorola Standards and Guidelines for Communication Sites "R56" (68P81089E50) and specified installation instructions for safe operation.■Slots and openings in the cabinet are provided for ventilation. Do not block or cover openings that protect the devices from overheating.■Only a qualified technician familiar with similar electronic equipment should service equipment.■Some equipment components can become extremely hot during operation. Turn off all power to the equipment and wait until sufficiently cool before touching.■Have personnel call in with their travel routes to help ensure their safety while traveling between remote sites.■Institute a communications routine during certain higher risk procedures where the on-site technician continually updates management or safety personnel of the progress so that help can be dispatched if needed.■Never store combustible materials in or near equipment racks. The combination of combustible material, heat and electrical energy increases the risk of a fire safety hazard.■Equipment shall be installed in site meeting the requirements of a "restricted access location," per UL60950-1, which is defined as follows: "Access can only be gained by service persons or by user who has been warned about the possible burn hazard on equipment metal housing. Access to the equipment is through the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location."Ì!CAUTIONBurn hazard. The metal housing of product may become extremely hot. Use caution when working around the equipment.Ì!CAUTIONAll Tx and Rx RF cables' outer shields must be grounded per Motorola R56 requirements.
Installation Volume 1IntroductionEnhanced Base Transceiver System (EBTS)3-4 68P80801E35-E 16-June-06Ì!CAUTIONDC input voltage shall be no higher than 60VDC. This maximum voltage shall include consideration of the battery charging "float voltage" associated with the intended supply system, regardless of the marked power rating of the equipment. Failure to follow this guideline may result in electric shock.Ì!CAUTIONAll Tx and Rx RF cables shall be connected to a surge protection device according to Motorola R56 documents. Do not connect Tx and Rx RF cables directly to outside antenna.
Base Radio Volume 2OverviewEnhanced Base Transceiver System (EBTS)1-2 68P80801E35-E 16-June-06Overview 1This chapter provides an overview of the 800 MHz Legacy, 800 MHz Gener-ation 2 Single Channel, 800 MHz and 900 MHz QUAD Channel, and 800/900 MHz QUAD+2 Base Radios (BRs) along with  technical information.FRU Number to Kit Number Cross ReferenceThe Single Carrier Base Radio section covers the 800 MHz Legacy and 800 MHz Generation 2 versions of the Base Radio (BR).  Information is presented generally for all models.  Information that is model specific noted in the text.For Generation 2 BR, both the 800 MHz Exciter and the 800 MHz Low Noise Exciter modules are supported subject to Table 1-5.For QUAD Channel 800 MHz BR use, all Single Carrier BR modules have undergone redesign. Therefore, Single Carrier BR modules are incompatible with the QUAD Channel 800 MHz BR. QUAD Channel 800 MHz BR modules are incompatible with the Single Carrier BR. Note Do not attempt to insert QUAD Channel 800 MHz BR modules into a Single Carrier BR or Single Carrier BR modules into a QUAD Channel 800 MHz BR.Note For QUAD Channel 900 MHz BR use, all Single Carrier BR modules are incompatible with the 900 MHz QUAD Channel BR. 900 MHz QUAD Channel BR modules are incompatible with the Single Carrier BR.Note Do not attempt to insert QUAD Channel 900 MHz BR modules into a Single Carrier BR or Single Carrier BR modules into a QUAD Channel 900 MHz BR.Table 1-1 FRU Number to Kit Number Cross ReferenceDescriptionFRU NumberKit NumberSingle Channel 800 MHz BRC TLN3334 CLN1469Single Channel BRC (MCI) TLN3425 CLN1472Enhanced Base Radio Controller DLN6446 CLN1653900 MHz QUAD Channel EX/CNTL DLN1203 CLF6242800 MHz QUAD Channel EX/CNTL CLN1497 CLF1560800/900 MHz QUAD+2 Channel XCVR DLN6654 PCUF1001
Volume 2 Base RadioQUAD Channel 900 MHz Base Radio OverviewEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 1-15QUAD Channel 900 MHz Base Radio Overview 1The QUAD Channel 900 MHz BR provides reliable, digital BR capabilities in a compact, software-controlled design. Voice compression techniques, time division multiplexing (TDM) and multi-carrier operation provide increased channel capacity. The QUAD Channel 900 MHz BR contains the four FRUs listed below:■QUAD Channel 900 MHz EX /Cntl■QUAD Channel 900 MHz Power Amplifier■QUAD Channel 800 MHz and 900 MHz Power Supply (DC)■QUAD Channel 900 MHz Receiver (qty. 4)The modular design of the QUAD Channel 900 MHz BR also offers increased shielding and provides easy handling. All FRUs connect to the backplane through blindmate connectors. Note Both the 800 MHz QUAD and 900 MHz QUAD Base Radios use the same backplane and cardcage but call out different FCC ID numbers.Figure 1-3 shows the front view of the BR.Figure 1-3 QUAD Channel 900 MHz  Base Radio (Typical) EBTS282Q_900120501JNM900 QUAD CHANNEL POWER AMPLIFIERQUAD CHANNEL POWER SUPPLY900 QUAD CHANNEL EX/CNTL 900 QUAD CHANNEL RECEIVER900 QUAD CHANNEL RECEIVER900 QUAD CHANNEL RECEIVER900 QUAD CHANNEL RECEIVERSTATUSRESETTX4TX4TX4TX4PSEX/CNTLPAREFRX1RX2RX3RX4RX4RX3RX2RX1
Base Radio Volume 2QUAD Channel 900 MHz Base Radio OverviewEnhanced Base Transceiver System (EBTS)1-16 68P80801E35-E 16-June-06QUAD Channel 900 MHz  Base Radio Controls and IndicatorsPower Supply and EX / CNTL  controls and indicators monitor BR status and operating conditions, and also aid in fault isolation. The Power Supply and EX / CNTL sections of this chapter discuss controls and indicators for both modules.The Power Supply has two front panel indicators. The EX / CNTL has twelve front panel indicators. The Power Supply power switch applies power to the BR. The EX / CNTL RESET switch resets the BR. QUAD Channel 900 MHz  Base Radio Performance SpecificationsQUAD Channel 900 MHz  Base Radio General SpecificationsTable 1-9 lists general specifications for the BR.Table 1-9 QUAD Channel 900 MHz  BR General SpecificationsSpecification Value or RangeDimensions:HeightWidthDepthWeight5 EIA Rack Units (RU)19" (482.6 mm)16.75" (425 mm)85 lbs. (38.6 kg)Operating Temperature 32° to 104° F (0° to 40° C)Storage Temperature -22° to 140° F (-30° to 60° C)Rx Frequency Range:900 MHz iDEN 901 - 902 MHzTx Frequency Range:900 MHz iDEN 940 - 941 MHzTx – Rx Spacing:900 MHz iDEN 39 MHzCarrier Spacing 25 kHzCarrier Capacity*1, 2, 3 or 4Frequency Generation SynthesizedDigital Modulation QPSK, M-16QAM, and M-64QAMPower Supply Inputs:VDC -48 VDC (-41 to -60 VDC)Diversity Branches Up to 3 Note * Multi-carrier operation must utilize adjacent, contiguous RF carriers.
Volume 2 Base RadioQUAD Channel 900 MHz Base Radio OverviewEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 1-17QUAD Channel 900 MHz  Base Radio Transmit SpecificationsTable 1-10 lists the BR transmit specifications.QUAD Channel 900 MHz  Base Radio Receive SpecificationsTable 1-11 lists the receive specifications.     Table 1-10 QUAD Channel 900 MHz BR Transmit Specifications Specification Value or RangeLow average output power per carrierHigh average output power per carrierAverage Power Output:(900 MHZ) Single Carrier 5.0W 52.0W(900 MHz) Dual Carrier 2.5W 26.0W(900 MHz) Triple Carrier 1.7W 16.1W(900 MHz) QUAD Carrier 1.3W 10.5WTransmit Bit Error Rate (BER) 0.01%Occupied Bandwidth 18.5 kHzFrequency Stability * 1.5 ppmRF Input Impedance 50 Ω (nom.)FCC Designation (FCC Rule Part 24):900 MHz QUAD BR ABZ89FC5798-PNote * Transmit frequency stability locks to an external site reference, which controls ultimate frequency stability to a level of 50 ppb.Table 1-11 QUAD Channel 900 MHz Receive SpecificationsSpecification Value or RangeStatic Sensitivity †:900 MHz BR  -108 dBm (BER = 8%)BER Floor (BER = 0.01%) ≥ -80 dBmIF Frequencies1st IF (All bands):2nd IF:73.35 MHz (1st IF)450 kHz (2nd IF)Frequency Stability * 1.5 ppm
Base Radio Volume 2QUAD Channel 900 MHz Base Radio OverviewEnhanced Base Transceiver System (EBTS)1-18 68P80801E35-E 16-June-06QUAD Channel 900 MHz  Base Radio Theory of OperationThe QUAD Channel 900 MHz  BR operates with other site controllers and equipment and must be properly terminated. The following description assumes such a configuration. Figure 1-10 show an overall block diagram of the QUAD Channel 900 MHz  BR.Power is applied to the DC Power inputs located on the QUAD Channel 900 MHz  BR backplane. The DC Power input is connected if -48 VDC or batteries are used in the site.Power is applied to the BR by setting the Power Supply power switch to the ON position. Upon power-up, the QUAD Channel 900 MHz  BR performs self-diagnostic tests to ensure the integrity of the unit. These tests, which include memory and Ethernet verification routines, primarily examine the EX / CNTL. After completing self-diagnostic tests, the QUAD Channel 900 MHz  BR reports alarm conditions on any of its modules to the site controller via Ethernet. Alarm conditions may also be verified locally. Local verification involves using the service computer and the STATUS port located on the front of the QUAD Channel 900 MHz  EX / CNTL.The software resident in FLASH on the EX / CNTL registers the BR with the site controller via Ethernet. After BR registration on initial power-up, the BR software  downloads via resident FLASH or Ethernet and executes from RAM. The download includes operating parameters for the QUAD Channel 900 MHz  BR. These parameters allow the QUAD Channel 900 MHz  BR to perform call processing functions. RF Input Impedance 50 Ω (nom.)FCC Designation (FCC Rule Part 15):900 MHz BR  ABZ89FR5799Note † Measurement referenced from single receiver input port of BR.Note * Stability without site reference connected to station. Receive frequency stability locks to an external site reference, which controls ultimate frequency stability to a level of 50 ppb.Table 1-11 QUAD Channel 900 MHz Receive Specifications Specification Value or Range
Volume 2 Base RadioQUAD Channel 900 MHz Base Radio OverviewEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 1-19After software downloads to the BR via Ethernet, FLASH memory stores the software object. Upon future power-ups, the software object in FLASH loads into RAM for execution.The BR operates in a TDMA (Time Division Multiple Access) mode. This mode, combined with voice compression techniques, increases channel capacity by a ratio of as much as six to one. TDMA divides both the receive and transmit signals of the BR into six individual time slots. Each receive slot has a corresponding transmit slot. This pair of slots comprises a logical RF channel. The BR uses diversity reception for increased coverage area and improved quality. The Receiver modules within the QUAD Channel 900 MHz  BR contain three receiver paths. Two-branch diversity sites use two Receiver paths, and three-branch diversity sites use three Receiver paths. All Receiver paths within a given Receiver module are programmed to the same receive frequency. Signals from each receiver arrive at the EX / CNTL module. This module performs a diversity combining algorithm on the signals. The resultant signal undergoes an error-correction process. Then, via Ethernet, the site controller acquires the signal, along with control infor-mation about signal destination.Two separate FRUs comprise the transmit section of the QUAD Channel 900 MHz  BR. These are the Exciter portion of the EX / CNTL and the Power Amplifier (PA). The Exciter processes commands from the CNTL, assuring transmission in the proper modulation format. Then the low-level signal enters the PA. The PA amplifies this signal to the desired output power level. The PA is a continuously keyed linear amplifier. A power control routine monitors the output power of the BR. The routine adjusts the power as necessary to maintain the proper output level.
Volume 2 Base RadioEnhanced Base Transceiver System (EBTS)16-June-06  68P80801E35-E 1-35Figure 1-10 800 and 900 MHZ QUAD Channel Base Radio Functional Block Diagram16.8MHz2.4MHz48MHzHost SPIHost SPI16.8MHzSTATUSPORTRS-2325 MHZEXTERNALREFERENCEETHERNET1PPS & SLOT TIMINGRX1 DATARX2 DATARX3 DATARX4 DATARx1&2Rx3&4POWER AMPLIFIER MODULETx_I Tx_QEXCITER-BASE RADIO CONTROLLERHOSTu’PSDRAMRECEIVEDSPETHERNETEEPROMFLASHPLL/VCOsTRANSMITDSPTISICTX RECLOCKBUFFERSRX SPIBASE RADIO CONTROLLERExciterIO LATCHESRECEIVEDSPINTERFACEADDRESS DECODE,MEMORY, ADCSPI BUSLINEARDRIVERFINALLINEARAMPSCOMBINERSPLITTERRF OUTTO RFDS(TX ANTENNA)DAC VCOs/SynthsIQODCTLINEAR RFAMPLIFIERRF INRF FEEDBACKDC POWER SUPPLY MODULEINPUT FILTERSTART-UPINVERTERCIRCUITRYEXTERNALDC INPUT41 - 60 VDCCLOCKGENERATOR133 KHZ 267 KHZ133 KHZ14.2 VCONVERTER3.3 VCONVERTER+28 VDCTO BACKPLANE+14.2 VDCTO BACKPLANE+3.3 VDCTO BACKPLANEMain ConverterMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERRX INTERFACE,ADDRESS DECODE.MEMORY, DIAGNOSTICSPREAMPLIFIERSPLITTER/ BYPASSVCO SYNTHSPLITTERRF INFROM RFDS(BRANCH 2)MIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERRX INTERFACE,ADDRESS DECODE.MEMORY, DIAGNOSTICSPREAMPLIFIERSPLITTER/ BYPASSVCO SYNTHSPLITTERRF INFROM RFDS(BRANCH 3)MIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXER IF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERRX INTERFACE,ADDRESS DECODE.MEMORY, DIAGNOSTICSPREAMPLIFIERSPLITTER/ BYPASSVCO SYNTHSPLITTERRF INFROM RFDS(BRANCH 1)RECEIVER 2RECEIVER 3RECEIVER 4RECEIVER 1MIXERIF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXERIF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERMIXERIF FILTERAMP, AGCABACUSRECEIVERICLPF, AMP,FILTERRX INTERFACE,ADDRESS DECODE.MEMORY, DIAGNOSTICSPREAMPLIFIERSPLITTER/ BYPASSVCO SYNTHSPLITTERSPI BUSSPI BUSSPI BUSADDRESS DECODE,MEMORY, ADCQUAD RX IN DISTRIBUTION16.8MHzRECEIVER 4
Base Radio Controllers Volume 2OverviewEnhanced Base Transceiver System (EBTS)2-2 68P80801E35-E 16-June-06Overview 2This chapter provides information on Base Radio Controllers (BRCs).FRU Number to Kit Number Cross ReferenceBase Radio Controller (BRC) Field Replaceable Units (FRUs) are available for the iDEN EBTS. The FRU contains the BRC kit and required packaging. Table 2-1 provides a cross reference between BRC FRU numbers and kit numbers. Table 2-1 FRU Number to Kit Number Cross ReferenceDescriptionFRU NumberKit NumberSingle Channel 800 MHz Base Radio Controller TLN3334 CLN1469Enhanced Base Radio Controller DLN6446 CLN1653QUAD Channel 900 MHz Exciter/BR Controller DLN1203 CLF1792QUAD Channel 800 MHz Exciter/BR Controller  CLN1497 CLF1560
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-28 68P80801E35-E 16-June-06900 MHz QUAD Channel Base Radio Controller 2900 MHz QUAD Channel Base Radio Controller OverviewThe Base Radio Controller (BRC) provides signal processing and operational control for Base Radio modules. The BRC module consists of a printed circuit board, a slide-in housing, and associated hardware.The BRC memory contains the operating software and codeplug. The software defines BR operating parameters, such as output power and operating frequency. The BRC connects to the Base Radio backplane with one 168-pin FutureBus+ connector and one blindmate RF connector. Two Torx screws secure the BRC in the Base Radio chassis. Figure 2-6 shows a top view of the EX/CNTL (model CLF1560) with the cover removed.Figure 2-6 900 MHz QUAD Channel Base Radio Controller, version DLN1203 (with cover removed) 900 MHz QUAD Channel Base Radio Controller Controls and IndicatorsThe BRC monitors the functions of other Base Radio modules. The LEDs on the front panel indicate the status of BRC-monitored modules. All LEDs on the BRC front panel normally flash three times upon initial power-up. A RESET switch allows a manual reset of the Base Radio. Figure 2-7 shows the front panel of the BRC.
Volume 2 Base Radio Controllers900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 2-29Figure 2-7 900 MHz QUAD Channel BR Controller (Front View)IndicatorsTable 2-12 lists and describes the BRC LEDs. QUAD CHANNEL EX/CNTLSTATUSRESETTX4TX4TX4TX4PSEX/CNTLPAREFRX1RX2RX3RX4EBTS316Q013001JNMTable 2-12 900 MHz QUAD Channel BR Controller Indicators LED ColorModuleMonitored Condition IndicationsPS Red Power SupplySolid (on) FRU failure indication - Power Supply has a major alarm, and is out of serviceFlashing (on)Power Supply has a minor alarm, and may be operating at reduced performanceOff Power Supply is operating normally (no alarms)EXBRC Red Controller/ExciterSolid (on)FRU failure indication - Controller/Exciter has a major alarm, and is out of service (Note: Upon power-up of the BR, this LED indicates a failed mode until BR software achieves a known state of operation.)Flashing (on)Controller/Exciter has a minor alarm, and may be operating at reduced performanceOff Controller/Exciter is operating normally (no alarms)PA Red Power AmplifierSolid (on) FRU failure indication - PA has a major alarm, and is out of serviceFlashing (on)PA has a minor alarm, and may be operating at reduced performanceOff PA is operating normally (no alarms)
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-30 68P80801E35-E 16-June-06REF RedController Station ReferenceSolid (on) FRU failure indication - Controller Station Reference has a major alarm, and is out of serviceFlashing (on)BRC has a minor alarm, and may be operating in a marginal regionOff BRC is operating normally (no alarms)RX1RX2RX3RX4Red Receiver #1, #2, #3, or #4Solid (on) FRU failure indication - Receiver (#1, #2, #3 or #4) has a major alarm, and is out of serviceFlashing (on)Receiver (#1, #2, #3 or #4) has a minor alarm, and may be operating at reduced performanceOff Receiver (#1, #2, #3 or #4) is operating normally (no alarms)TX1 Green BRSolid (on) Station Transmit Carrier #1 is keyedFlashing (on) Station Transmit Carrier #1 is not keyedOff Station is out of service, or power is removedTX2 Green BRSolid (on) Station Transmit Carrier #2 is keyedFlashing (on) Station Transmit Carrier #2 is not keyedOff Station is out of service, or power is removedTX3 Green BRSolid (on) Station Transmit Carrier #3 is keyedFlashing (on) Station Transmit Carrier #3 is not keyedOff Station is out of service, or power is removedTX4 Green BRSolid (on) Station Transmit Carrier #4 is keyedFlashing (on) Station Transmit Carrier #4 is not keyedOff Station is out of service, or power is removedTable 2-12 900 MHz QUAD Channel BR Controller Indicators  (continued)LED ColorModuleMonitored Condition Indications
Volume 2 Base Radio Controllers900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 2-31ControlsTable 2-13 lists the controls and descriptions. STATUS ConnectorTable 2-14 the pin-outs for the STATUS connector. Table 2-13 900 MHz QUAD Channel BR Controller ControlsControl DescriptionRESET Switch A push-button switch used to manually reset the BR.STATUS connectorA 9-pin connector used for connection of a service computer, providing a convenient means for testing and configuring.Table 2-14 Pin-outs for the STATUS ConnectorPin-out Signal1 not used2TXD3RXD4 not used5GND6 not used7 not used8 not used9 not used
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-32 68P80801E35-E 16-June-06900 MHz QUAD Channel Base Radio Controller Theory of OperationTable 2-15 briefly describes the BRC circuitry. Figure 2-14 is a functional block diagram of the BRC. Table 2-15 900 MHz QUAD Channel BR Controller CircuitryCircuit DescriptionHost Microprocessor Contains integrated circuits that comprise the central controller of the BRC and stationNon-Volatile MemoryConsists of: FLASH containing the station operating softwareEEPROM containing the station codeplug dataVolatile Memory Contains SDRAM to store station software used to execute commands.Ethernet InterfaceProvides the BRC with a 10Base2 Ethernet communication port to network both control and compressed voice dataRS-232 Interface Provides the BRC with an RS-232 serial interfaceDigital Signal Processors Performs high-speed modulation/demodulation of compressed audio and signaling dataTISIC Contains integrated circuits that provide timing reference signals for the stationTX ReclockContains integrated circuits that provide highly stable, reclocked transmit signals and peripheral transmit logicRX DSP SPI Contains integrated circuits that provide DSP SPI capability and peripheral receive logicStation Reference CircuitryGenerates the 16.8 MHz and 48 MHz reference signals used throughout the stationInput Ports  Contains 16 signal input ports that receive miscellaneous inputs from the BROutput PortsContains 40 signal output ports, providing a path for sending miscellaneous control signals to circuits throughout the BRRemote Station Shutdown Provides software control to cycle power on the BR
Volume 2 Base Radio Controllers900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 2-33Host MicroprocessorThe host microprocessor is the main controller for the BR. The processor operates at a 50-MHz clock speed. The processor controls Base Radio operation according to station software in memory. Station software resides in FLASH memory. For normal operation, the system transfers this software to non-volatile memory. An EEPROM contains the station codeplug.Note At BR power-up, the EXBRC LED indicates a major alarm. This indication continues until BR software achieves a predetermined state of operation. Afterward, the software turns off the EXBRC LED.Serial Communication BusesThe microprocessor provides a general-purpose SMC serial management controller bus.The SMC serial communications bus is an asynchronous RS-232 interface with no hardware handshake capability. The BRC front panel includes a nine-pin, D-type connector. This connector provides a port where service personnel may connect a service computer. Service personnel can perform programming and maintenance tasks via Man-Machine Interface (MMI) commands. The interface between the SMC port and the front- panel STATUS connector is via EIA-232 Bus Receivers and Drivers.Host ProcessorThe microprocessor incorporates 4k bytes of instruction cache and 4k bytes of data cache that significantly enhance processor performance.The microprocessor has a 32-line address bus. The processor uses this bus to access non-volatile memory and SDRAM memory. Via memory mapping, the processor also uses this bus to control other BRC circuitry. The microprocessor uses its Chip Select capability to decode addresses and assert an output signal. The eight chip-select signals select non-volatile memory, SDRAM memory, input ports, output ports, and DSPs.The Host processor... ■Provides serial communications between the Host Microprocessor and other Base Radio modules.■Provides condition signals necessary to access SDRAM.■Accepts interrupt signals from BRC circuits (such as DSPs). ■Organizes the interrupts, based on hardware-defined priority ranking.■The Host supports several internal interrupts from its Communications Processor Module. These interrupts allow efficient use of peripheral interfaces.■The Host supports 10 Mbps Ethernet/IEEE 802.3.
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-34 68P80801E35-E 16-June-06■Provides a 32-line data bus transfers data to and from BRC SDRAM and other BRC circuitry. Buffers on this data bus allow transfers to and from non-volatile memory, general input and output ports and DSPs.Non-Volatile MemoryBase Radio software resides in 2M x 32 bits of FLASH memory. The Host Microprocessor addresses the FLASH memory with 20 of the host address bus’ 32 lines. The host accesses FLASH data over the 32-line host data bus. A host-operated chip-select line provides control signals for these transactions. The FLASH contains the operating system and application code. The system stores application code in FLASH for fast recovery from reset conditions. Application code transfers from network or site controllers may occur in a background mode. Background mode transfers allow the station to remain operational during new code upgrades.The data that determines the station personality resides in a 32K x eight bit codeplug EEPROM. The microprocessor addresses the EEPROM with 15 of the host address bus’ 32 lines. The host accesses EEPROM data with eight of the data bus’ 32 lines. A host-operated chip-select line provides control signals for these transactions. During the manufacturing process, the factory programs the codeplug’s default data. The BRC must download field programming data from network and site controllers. This data includes operating frequencies and output power level. The station permits adjustment of many station parameters, but the station does not store these adjustments. Refer to the Software Commands chapter for additional information.Volatile MemoryEach BRC contains 8MB x 32 bits of SDRAM. The BRC downloads station software code into SDRAM for station use. SDRAM also provides short-term storage for data generated and required during normal operation. SDRAM is volatile memory. A loss of power or system reset destroys SDRAM data. The system performs read and write operations over the Host Address and Data buses. These operations involve column and row select lines under control of the Host processor’s DRAM controller. The Host address bus and column row signals sequentially refresh SDRAM memory locations.Ethernet InterfaceThe Host processor’s Communications Processor Module (CPM) provides the Local Area Network (LAN) Controller for the Ethernet Interface. The LAN function implements the CSMA/CD access method, which supports the IEEE 802.3 10Base2 standard.
Volume 2 Base Radio Controllers900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 2-35The LAN coprocessor supports all IEEE 802.3 Medium Access Control, including the following: ■framing ■preamble generation ■stripping■source address generation■destination address checkingThe PCM LAN receives commands from the CPU. The Ethernet Serial Interface works directly with the CPM LAN to perform the following major functions:■10 MHz transmit clock generation (obtained by dividing the 20 MHz signal provided by on-board crystal)■Manchester encoding/decoding of frames■electrical interface to the Ethernet transceiverAn isolation transformer provides high-voltage protection. The transformer also isolates the Ethernet Serial Interface (ESI) and the transceiver. The pulse transformer has the following characteristics:■Minimum inductance of 75 µH■2000 V isolation between primary and secondary windings■1:1 Pulse Transformer The Coaxial Transceiver Interface (CTI) is a coaxial cable line driver and receiver for the Ethernet. CTI provides a 10Base2 connection via a coaxial connector on the board. This device minimizes the number of external compo-nents necessary for Ethernet operations. A DC/DC converter provides a constant voltage of -9 Vdc for the CTI from a 3.3 Vdc source. The CTI performs the following functions:■Receives and transmits data to the Ethernet coaxial connection■Reports any collision that it detects on the coaxial connection■Disables the transmitter when packets are longer than the legal length (Jabber Timer)
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-36 68P80801E35-E 16-June-06Digital Signal ProcessorsThe BRC includes two Receive Digital Signal Processors (RXDSPs) and a Transmit Digital Signal Processor (TXDSP). These DSPs and related circuitry process compressed station transmit and receive audio or data. The related circuitry includes the TDMA Infrastructure Support IC (TISIC) and the TISIC Interface Circuitry. The DSPs only accept input and output signals in digitized form.The RXDSP inputs are digitized receiver signals. The TXDSP outputs are digitized voice audio and data (modulation signals). These signals pass from the DSP to the Exciter portion of the EXBRC. DSPs communicate with the Microprocessor via an eight-bit, host data bus on the host processor side. For all DSPs, interrupts drive communication with the host.The RXDSPs operate from an external 16.8 MHz clock, provided by the local station reference. The RXDSP internal operating clock signal is 150MHz, produced by an internal Phase-Locked Loop (PLL). The RXDSPs accept digitized signals from the receivers through Enhanced Synchronous Serial Interface (ESSI) ports. Each of two ESSI ports on a RXDSP supports a single carrier (single receiver) digital data input. The DSP circuitry includes two RXDSPs. These allow processing of up to four carriers (four receivers).The RXDSP accesses its DSP program and signal-processing algorithms in 128k words of internal memory. The RXDSPs communicate with the host bus over an 8-bit interface. Each RXDSP provides serial communications to its respective receiver module for receiver control via a Serial Peripheral Interface (SPI). The SPI is a parallel-to-serial conversion circuit, connected to the RXDSP data bus. Each RXDSP communicates to two receive modules through this interface.Additionally, a serial control path connects the two RXDSPs and the TXDSP. The Synchronous Communications Interface (SCI) port facilitates this serial control path. For initialization and control purposes, one RXDSP connects to the TISIC device.The TXDSP operates at an external clock speed of 16.8 MHz, provided by the EXBRC local station reference. The TXDSP internal operating clock is 150MHz, produced by an internal Phase Lock Loop (PLL). The TXDSP sends up to four carriers of digitized signal to the EX11 exciter. The exciter converts the digital signal to analog. Also at the exciter, a highly stable clock reclocks the digital data. Reclocking enhances transmit signal integrity. Two framed and synchronized data streams result. One data stream is I-data, and the other is the Q-data stream.
Volume 2 Base Radio Controllers900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 2-37The TXDSP contains its own, internal address and data memory. The TXDSP can store 128k words of DSP program and data memory. An eight-bit interface handles TXDSP-to-host bus communications.TISICThe TISIC controls internal DSP operations. This circuit provides the following functions:■For initialization and control, interfaces with one RXDSP via the DSP address and data buses.■Accepts a 16.8 MHz signal from Station Reference Circuitry.■Accepts a 5 MHz signal, modulated with one pulse per second (1 PPS) from the site reference. ■Demodulates the 1 PPS ■Outputs a 1 PPS signal and a windowed version of this signal for network timing alignment.■Outputs a 2.4 MHz reference signal used by the Exciter.■Generates 15 ms and 7.5 ms ticks. (These ticks synchronize to the 1 PPS time mark. The system decodes the time mark from the site reference. Then the system routes the reference to the TXDSP and RXDSPs.)Station Reference CircuitryThe Station Reference Circuitry is a phase-locked loop (PLL). This PLL consists of a high-stability, Voltage-Controlled, Crystal Oscillator (VCXO) and a PLL IC. GPS output from the iSC connects to the 5 MHz/1 PPS BNC connector on the BR backplane. Wiring at this connector routes signals to EXBRC station reference circuitry. The PLL compares the 5 MHz reference frequency to the 16.8 MHz VCXO output. Then the PLL generates a DC correction voltage. The PLL applies this correction voltage to the VCO through an analog gate. The analog gate closes when three conditions coexist: (1) The 5 MHz tests stable. (2) The PLL IC is programmed. (3) Two PLL oscillator and reference signal output alignments occur. When the gate enables, the control voltage from the PLL can adjust the high-stability VCXO frequency. The adjustment can achieve a stability nearly equivalent to that of the external, 5 MHz frequency reference.The correction voltage from the PLL continuously adjusts the VXCO frequency. The VXCO outputs a 16.8 MHz clock signal. The circuit applies this clock signal to the receiver, 48 MHz reference and TISIC. The receivers use the 16.8MHz as the clock input and synthesizer reference.
Base Radio Controllers Volume 2900 MHz QUAD Channel Base Radio ControllerEnhanced Base Transceiver System (EBTS)2-38 68P80801E35-E 16-June-06The 48 MHz EXBRC synthesizer uses the 16.8 MHz as its synthesizer reference. The 48 MHz synthesizer output is the clock input for the TXDSP I and Q data reclock circuitry.The TISIC divides the 16.8 MHz signal by seven, and outputs a 2.4 MHz signal. This output signal then becomes the 2.4 MHz reference for the Exciter.Input PortsOne general-purpose input register provides for BRC and station circuit input signals. The register has 16 input ports. The Host Data Bus conveys input register data to the Host Microprocessor. Typical inputs include 16.8 and 48 MHz Station Reference Circuitry status outputs and reset status outputs.Output PortsTwo general-purpose output registers distribute control signals from the Host Microprocessor to the BRC and station circuitry. One register has 32 output ports and the other register has 8 output ports. Control signal distribution occurs over the backplane. The Host Data Bus drives the output ports’ latched outputs. Typical control signals include front-panel LED signals and SPI peripheral enable and address lines.Remote Station ShutdownThe BRC contains power supply shutdown circuitry. This circuitry can send a shutdown pulse to the Base Radio Power Supply. BRC software generates the shutdown control pulse. After receiving a shutdown pulse, the power supply turns off BR power. Shut down power sources include 3.3, 28.6 and 14.2 Vdc sources throughout the BR. Due to charges retained by BR storage elements, power supply voltages may not reach zero. The shutdown only assures that the host processor enters a power-on-reset state. A remote site uses the shutdown function to perform a hard reset of all BR modules.
Volume 2 Base Radio ControllersEnhanced Base Transceiver System (EBTS)16-June-06  68P80801E35-E 2-55Figure 2-14 800 and 900 MHz QUAD Channel Base Radio Controller Functional Block Diagram (Sheet 1 of 2) SPIBUSPHASEDETECTION/FILTERINGHIGHSTABILITYVCXO48 MHZ16.8MHZPOWERSUPPLY EXCITER/CONTROL PA REF RX1 RX2 RX3 RX4 TX1 TX2 TX3 TX4P0 OUTLEDCONTROLLINESHOSTLATCH12FRONT PANEL LEDS REMOTE STATION3.3VP0_OUTSHUTDOWNCIRCUITRYSHUTDOWN(TO POWERSUPPLY)SHUTDOWN CIRCUITRYSYNTHESIZERIC / CIRCUITRY5MHZ_1PPSBASE RADIOINPUTHIGHSTABILITYVCXOPHASEDETECTION/FILTERING/CONTROLSTEARINGLINEDISCONNECT/CONNECTCONTROLGATINGSPIBUS16.8 MHZSYNTHESIZERIC / CIRCUITRYSTEARINGLINESTATION REFERENCE CIRCUITRYTRANSMIT REFERENCE CIRCUITRY5MHZ1PPS
Base Radio Controllers Volume 2Enhanced Base Transceiver System (EBTS)2-56 68P80801E35-E 16-June-06Figure 2-15 800 and 900 MHz QUAD Channel Base Radio Controller Functional Block Diagram (Sheet 2 of 2) HOSTMICRO-ETHERNETSERIALINTERFACE TRANS-CDRCV RXTRMT TXCLSN10BASE2COAXETHERNETSERIALINTERFACECEIVERISOLATIONTRANSFORMERPROCESSORSCC18SDRAM4M x 16SDRAM4M x 16SDRAM4M x 16SDRAM4M x 16GPLA0, A[8,9,17,18,20:29],RAS,CAS,WECS2CS3D[0:31]D[0:15]D[16:31]D[0:15]D[16:31]BUFFERBUFFERBUFFERBUFFERBUFFERBUFFERD[0:31]D[0:7]A[10:31]MA[21:0]DSP_D[31:24]A[0:7]DSP_A[31:24]MD[31:0]EIA-232BUSRECEIVERS/DRIVERS2STATUS PORT(9 PIN D CONNECTORON BRC FRONT PANEL)2BUFFER33SPI BUS TO/FROM STATION MODULESFLASH1M x 16FLASH1M x 16FLASH1M x 16FLASH1M x 16CS0CS1MD[0:15]MD[16:31]MD[0:15]MD[16:31]1616161616 161616MA[2:21]MA[2:21]EEPROM32k x 8MD[24:31]MA[0:14]CS4P1_OUTLATCHP0_OUTLATCHMD[0:32]MD[24:31]P0_INBUFFERMD[16,17,20-24,28-31]STATUS BUSFROMSTATION MODULESP0_IN8CONTROL BUSTOSTATION MODULESP0_OUT/P1_OUT328TRANSMITDIGITALSIGNALPROCESSOR(TX DSP)SINGLE ENDTO DIFFERENTIALTRANSMITCLOCK ANDFRAME SYNCHCIRCUITRYI/Q DATASERIAL DATATO EXCITERDIFFERENTIALTO SINGLE ENDRX1 SERIAL DATARECEIVEDIGITALSIGNALPROCESSOR(RX DSP 1)RECEIVEDIGITALSIGNALPROCESSOR(RX DSP 2)TISICA[0:5]D[0, 8:23]PARALLELTO SERIALCIRCUITRYD[16:23]D[16:23]D[0, 23]SPI BUS TORECEIVER 1 & 2SPI BUS TORECEIVER 3 & 42.4 MHz1 PPS TIMING, CONTROL/ SLOT TIMING/RESETNETWORKEDSCI16.8MHZ48 MHZSPIBUSSPIBUSEXCITERSPICONTROLDSP SPISPI BUSTO EXCITERDIGITAL SIGNAL PROCESSING CIRCUITRYDIGITAL SIGNAL PROCESSING CIRCUITRYDIFFERENTIALTO SINGLE ENDDIFFERENTIALTO SINGLE ENDDIFFERENTIALTO SINGLE END50 MHZCLOCKFRONT PANELRESETDRAM MEMORYETHERNET INTERFACENON-VOLATILE MEMORY EXPANDED STATUS INPUTAND OUTPUT CONTROL CIRCUITRYEXTENDED HOSTBUS BUFFERS40TO EXCITER5MHZ1PPSRX2 SERIAL DATARX3 SERIAL DATARX4 SERIAL DATAHOST ADDRESS BUSHOST DATA BUSHOST BUFFERED DATA BUSHOST BUFFERED ADDRESS BUSHOST-DSP BUFFERED DATA BUSHOST-DSP BUFFERED ADDRESS BUSSERIAL MANAGEMENT CONTROLLER (SMC2)SERIAL PERIPHERAL INTERFACE
Base Radio Exciter Volume 2OverviewEnhanced Base Transceiver System (EBTS)4-2 68P80801E35-E 16-June-06Overview 4This chapter provides technical information for the Exciter (EX). FRU Number to Kit Number Cross ReferenceExciter Field Replaceable Units (FRUs) are available for the iDEN EBTS. The FRU contains the Exciter kit and required packaging. Table 4-1 provides a cross reference between Exciter FRU numbers and kit numbers. Table 4-1 FRU Number to Kit Number Cross ReferenceDescriptionFRU NumberKit NumberSingle Channel Exciter (800 MHz) TLN3337 CLF1490QUAD Channel 900 MHz Exciter/Base Radio Controller) CLN1497 CLF6452QUAD Channel 800 MHz Exciter/Base Radio Controller  CLN1497 CLF1560LNODCT (Low Noise Offset Direct Conversion Transmit) Exciter (800 MHz) TLN3337 CLF1789
Base Radio Exciter Volume 2QUAD Channel 900 MHz ExciterEnhanced Base Transceiver System (EBTS)4-12 68P80801E35-E 16-June-06QUAD Channel 900 MHz Exciter  4QUAD Channel 900 MHz Exciter OverviewThe Exciter and the Power Amplifier (PA) provide the transmitter functions of the QUAD Channel 900 MHz Base Radio.  The Exciter module consists of a printed circuit board, a slide in housing, and associated hardware. The BRC shares the printed circuit board and housing.The Exciter connects to the Base Radio backplane through a 168-pin connector and two blindmate RF connectors. Controller and exciter circuitry also interconnect on the Exciter/Controller module. Two Torx screws on the front of the Exciter secure it to the chassis. An LED identifies the Exciter’s operational condition, as described in the manual’s Controller section.  The Base Radio section of the manual provides specifications for transmitter circuitry. This information includes data on the Exciter and PAs.Figures 4-4 shows the Exciter with the cover removed.Figure 4-3 900 MHz QUAD Channel Exciter (with cover removed)
Volume 2 Base Radio ExciterQUAD Channel 900 MHz ExciterEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 4-13900 MHz QUAD Channel Exciter Theory of OperationTable 4-4 describes the basic circuitry of the Exciter. Figure 4-7 show the QUAD Carrier Exciter’s functional block diagram.Table 4-4 900 MHz Exciter Circuitry Circuit DescriptionLNODCT ICUp-converts baseband data to the transmit frequencyDown-converts the PA feedback signal to basebandUses a baseband Cartesian feedback loop system, necessary to obtain linearity from the transmitter and avoid splattering power into adjacent channelsPerforms training functions for proper linearization of the transmitterMemory & A/D ConverterServes as the main interface between the synthesizer, Tranlin IC, A/D, and EEPROM on the Exciter, and the BRC via the SPI busFrequency Synthesizer CircuitryConsists of a phase-locked loop and VCOProvides a LO signal to the LNODCT IC for the second up-conversion and first down-conversion of the feedback signal from the PA1025 MHz VCO (900 MHz BR)Provides a LO signal to the LNODCT IC, for up-conversion to the transmit frequency90.3 MHz VCO (900 MHz BR)Provides a LO signal to LNODCT IC, for the up-conversion and for the down-conversion of the feedback signal. The mixed output becomes the LO signal for Transmit signal up- and down- conversionRegulator Circuitry Provides a regulated voltage to various ICs and RF devices located on the ExciterLinear RF amplifier Stages Amplifies the RF signal from the Exciter IC to an appropriate level for input to the PA
Base Radio Exciter Volume 2QUAD Channel 900 MHz ExciterEnhanced Base Transceiver System (EBTS)4-14 68P80801E35-E 16-June-06Memory CircuitryThe memory circuitry is an EEPROM on the Controller portion of the Exciter/Controller module.  The Controller performs memory read and write opera-tions over the parallel bus.  The memory device stores the following data...■kit number■revision number■module specific scaling and correction factors■serial number■free form information (scratch pad)A/D Converter CircuitryAnalog signals from various areas throughout the Exciter board enter the A/D converter (A/DC).  The A/DC converts these analog signals to digital form. Upon request of the BRC, A/DC output signals enter the BRC via SPI lines. The Controller periodically monitors all signals.Some of the monitored signals include amplifier bias and synthesizer signals. Low Noise Offset Direct Conversion Transmit (LNODCT) IC CircuitryThe Low Noise IC is a main interface between the Exciter and BRC. The BRC’s Digital Signal Processor (DSP) sends digitized signals (baseband data) to the Exciter over the DSP data bus.The differential data clock signal serves as a 2.4 MHz reference signal to the Low Noise IC’s internal synthesizer.  The Low Noise IC compares the reference signal with the outputs of Voltage Controlled Oscillators (VCOs). The Low Noise IC might sense that a VCO’s output is out of phase or off-frequency. If so, then the Low Noise IC sends correction pulses to the VCO. The pulses adjust VCO output, thereby matching phase and frequency with the reference. The Low Noise IC up-converts baseband data from the BRC to the transmit frequency. The Low Noise IC also down-converts the Transmit signal from the Power Amplifier to baseband data for cartesian feedback linearization.The BRC uses the Serial Peripheral Interface (SPI) bus to communicate with the Low Noise IC. The SPI bus serves as a general purpose, bi-directional, serial link between the BRC and other Base Radio modules, including the Exciter.  The SPI carries control and operational data signals to and from Exciter circuits.
Volume 2 Base Radio ExciterQUAD Channel 900 MHz ExciterEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 4-15Synthesizer CircuitryThe synthesizer circuit consists of the Phase-Locked Loop (PLL) IC and associated circuitry.  This circuit’s controls the 1025 MHz VCO signal. An internal phase detector generates a logic pulse. This pulse is proportional to the phase or frequency difference between the reference frequency and loop pulse signal. The charge pump circuit generates a correction signal. The correction signal moves up or down in response to phase detector output pulses.  The correction signal passes through the low-pass loop filter. The signal then enters the 1025 MHz Voltage Controlled Oscillator (VCO) circuit.  1025 MHz Voltage Controlled Oscillator (VCO)For proper operation, the VCO requires a very low-noise, DC supply voltage.  An ultra low-pass filter prepares the necessary low-noise voltage and drives the oscillator. A portion of the oscillator output signal enters the synthesizer circuitry.  The circuitry uses this feedback signal to generate correction pulses. The 1025MHz VCO output mixes with the 90.3 MHz VCO output. The result is a Local Oscillator [LO) signal for the Low Noise IC. The LNODCT uses this LO signal to up-convert the programmed transmit frequency.  The Low Noise IC also uses the LO signal to down-convert the PA feedback signal.90.3 MHz Voltage Controlled Oscillator (VCO)The synthesizer within the Low Noise IC sets the 90.3 MHz signal. The 90.3 MHz VCO provides a LO signal to the LNODCT IC. The Low Noise IC uses this signal in up-converting and down-converting the feedback signal. Regulator CircuitryThe voltage regulators generate three regulated voltages: +3 Vdc, +5 Vdc and +11.7 Vdc. The regulators obtain input voltages from the +3.3 Vdc and +14.2 Vdc backplane voltages.  The regulated voltages power various ICs and RF devices in the Exciter.Linear RF Amplifier StagesThe linear RF amplifiers boost the RF signal from the Low Noise IC. The RF Amplifier generates an appropriate signal level to drive the PA.
Volume 2 Base Radio ExciterEnhanced Base Transceiver System (EBTS)16-June-06  68P80801E35-E 4-23Figure 4-7 800 and 900 MHz Exciter Board Functional Block Diagram DIFFERENTIALDATA & CLOCKFROMBRC MODULEADDRESS BUSFROM CONTROLMODULESPI BUSTO/FROM CONTROLMODULEADDRESS DECODE, MEMORY, & A/DCONVERTER CIRCUITRYEXCITER IC CIRCUITRY 970 MHZVCO CIRCUITRYSYNTHESIZERCIRCUITRYLINEAR RF AMPLIFIERCIRCUITRYLOINJECTIONCIRCUITRYMEMORYA/DCONVERTERVARIOUSSIGNALSTO MONITORDCFILTER+10 VCONTROL VOLTAGEOSCILLATORCHARGEPUMP2.4 MHZVCO FEEDBACKCHIPSELECTSPI BUS (CLOCK & DATA)FROM BACKPLANEPHASELOCKEDLOOPICRINFIN90.3VCOCIRCUITRYOSCILLATORBUFFERAMPLNODCT IC CIRCUITRYLNODCT ICTX DATA & CLOCKLOW-PASSLOOPFILTERBUFFERVCOFEEDBACKRF OUTPUTTO PA MODULEDACIQRF FEEDBACKFROM PA MODULEBUFFERAMPBPFREGULATORCIRCUITRY+11.7 VREGULATOR+14.2 VFROMBACKPLANE+3 VSOURCE+11.7 VSOURCE+5 VSOURCE+5 VREGULATOR+3 VREGULATOR(U3702)EBTS283Q080601JNMNOTE: Where two frequencies are given, frequency without parentheses applies to 800 MHz BR only and frequency with parentheses applies to 900 MHz BR only.+3.3 V
Power Amplifier Volume 2OverviewEnhanced Base Transceiver System (EBTS)5-2 68P80801E35-E 16-June-06Overview 5This section provides technical information for the Power Amplifier (PA).FRU Number to Kit Number Cross ReferencePower Amplifier (PA) Field Replaceable Units (FRUs) are available for the iDEN EBTS. The FRU contains the PA kit and required packaging. Table 5-1 provides a cross reference between PA FRU numbers and kit numbers. Table 5-1 FRU Number to Kit Number Cross ReferenceDescriptionFRU NumberKit Number40 W- 800 MHz Single Channel Base Radio PA TLF2020 CLF177270 W- 800 MHz Single Channel Base Radio PA TLN3335 CLF177152 W- 900 MHz QUAD Channel Base Radio PA DLN1202 CTF108252 W- 800 MHz QUAD Channel Base Radio PA CLF1499 CLF1400QUAD+2 Channel Base Radio PA DLN6655 CLF1835
Volume 2 Power AmplifierPower Amplifier OverviewEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-3Power Amplifier Overview     5Note The power outputs discussed on this section for the 800 MHz QUAD and 900 MHz QUAD Power Amplifiers are referenced to the single carrier mode, operating at 52 W average power output from the Power Amplifier’s output connector.General Specifications of the transmitter circuitry, including the Exciter and PAs, are provided in Base Radio Overview section. Figure 5-1 shows the 40W, 800 MHz PA. Figure 5-2 shows the 70W, 800 MHz PA. Figure 5-3 shows the 800 MHz QUAD PA (the 900 MHz QUAD PA is similar in appearance). Figure 5-4 shows the QUAD+2 PA.40W-800 MHz, 70W-800 MHz, 800 MHz QUAD and 900 MHz QUADThe Power Amplifier (PA), with the Exciter, provides the transmitter functions for the Base Radio.  The PA accepts the low-level modulated RF signal from the Exciter. The PA then amplifies the signal for transmission and distributes the signal through the RF output connector. The 800 MHz Base Radio can be equipped with either 40 Watt PA, TLF2020 (version CLF1771) or 70 Watt PA, TLN3335 (version CLF1772). The 40W PA module consists of five hybrid modules, four pc boards, and a module heatsink/housing assembly.  The 70W PA module consists of eight hybrid modules, four pc boards, and a module heatsink/housing assembly. The PA connects to the chassis backplane through a 96-pin DIN connector and three blindmate RF connectors.  Two Torx screws located on the front of the PA hold it in the chassis.QUAD+2The QUAD+2 Power Amplifier is a hot-swap capable, forced convection cooled RF power amplifier. It accepts a low-level modulated RF signal from the transceiver module, and amplifies it for transmission via the site transmit antenna.
Power Amplifier Volume 2Power Amplifier OverviewEnhanced Base Transceiver System (EBTS)5-6 68P80801E35-E 16-June-06Figure 5-3 800/900 MHz QUAD PA Figure 5-4 QUAD+2 PA
Volume 2 Power AmplifierPA Theory of OperationEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-7PA Theory of Operation   5Table 5-2 describes the basic functions of the PA circuitry. Figures 5-5 and 5-6 show the functional block diagrams of 40W, 800 MHz and 70W, 800 MHz PA, respectively. Figures 5-7 shows a functional block diagram of 800 QUAD MHz. Figures 5-8 shows a functional block diagram of 900 MHz QUAD PA. Figures 5-9 shows a functional block diagram of QUAD+2 PA.Table 5-2 Power Amplifier Circuitry  Circuit DescriptionDC/Metering Board■Serves as the main interface between the PA and the backplane board■Accepts RF input from the Exciter via a blindmate RF connector■Routes the RF input via a 50 Ω stripline to the Linear Driver Module RF amplifier■Routes the RF feedback from the RF Combiner/Peripheral Module to the Exciter via a blindmate RF connector■Provides digital alarm and metering information of the PA to the BRC via the SPI bus ■Routes DC power to the fans and PA■Contains the thermistor that senses the PA temperature (800 MHz QUAD and 900 MHz QUAD)■Contains a Linear Driver Module and Linear Final Module Bias Enable Circuit (900 MHz QUAD)■Contains a Voltage Variable Attenuator Circuit (900 MHz QUAD)Linear Driver Module(LDM)■Contains two Class AB stages with the final stage in a parallel configuration (70W-800 MHz, 40W-800 MHz, 800 MHz QUAD)■Contains three cascaded Class AB stages with the first two stages configured as distributed amplifiers and the final stage in parallel configuration (900 MHz QUAD)■Amplifies the low level RF signal ~11mW average power from the Exciter via the DC/Metering Board (70W-800 MHz, 800 MHz QUAD*, 900 MHz QUAD*)■Amplifies the low-level RF signal ~8 mW average power from the Exciter via the DC/Metering Board  (40W- 800 MHz)■Provides an output of:~8 W (70W, 800MHz) average power ■~4 W (40W, 800 MHz) average power■~6 W (800 MHz QUAD* and 900 MHz QUAD*) average powerInterconnect Board■Provides RF interconnection from the LDM to the RF Splitter board■Provides DC supply filtering
Power Amplifier Volume 2PA Theory of OperationEnhanced Base Transceiver System (EBTS)5-8 68P80801E35-E 16-June-06RF Splitter/DC board■Interfaces with the DC/Metering Board to route DC power to the LFMs■Interfaces with the DC/Metering Board to route PA Bias Enable to the six Linear Final Modules (900 MHz Quad)■Contains splitter circuits that split the RF output signal of the LDM to the three Linear Final Modules (40W- 800 MHz)■Contains splitter circuits that split the RF output signal of the LDM to the six Linear Final Modules (70W- 800 MHz, 800 MHz QUAD and 900 MHz QUAD)Linear Final Module (LFM)■Each module contains two Class AB amplifiers in parallel. Each module amplifies one of three RF signals (~ 84 W average power) from the LDM (via the Splitter/DC board). Three LFMs provide a sum RF output of approximately 48 W average power, before losses. (40W,  800MHz)■Each module contains two Class AB amplifiers in parallel. Each module amplifies one of six RF signals (~ 8 W average power) from the LDM (via the Splitter/DC board). Six LFMs provide a sum RF output of approximately 97 W average power, before losses. (70W, 800MHz)■Each module contains two Class AB amplifiers in parallel. Each module amplifies one of six RF signals (~6W average power) from the LDM (via the splitter/DC Board). Six LFMs provide a sum RF output of approximately 73W average power , before losses. (800 MHZ QUAD* and 900 MHz QUAD*)RF Interconnect Board(40W- 800 MHz PA only)■Contains three transmission lines that interconnect the LFMs to the RF Combiner/Peripheral ModuleCombiner Board(70W-800 MHz,800 MHz QUAD, and900 MHz QUAD only)■Contains three separate Quadrature combiner circuits that respectively combine the six RF outputs from the LFMs into three signals. These three signals, in turn, are applied to the RF Combiner/Peripheral Module. Table 5-2 Power Amplifier Circuitry  (continued) Circuit Description
Volume 2 Power AmplifierPA Theory of OperationEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-9RF Combiner/Peripheral Module■Contains a combiner circuit that combines the three RF signals from the RF Interconnect Board (40W- 800 MHz PA) or the Combiner Board (70W-800 MHz PA). It then routes the combined RF signal through a single stage circulator and a Low Pass Filter. The final output signal is routed to the blindmate RF connector (40W-800 MHz and 70W-800 MHz PAs).■Contains a combiner circuit that combines the three RF signals from the Combiner Board. It then routes the combined RF signal through a dual stage circulator and a Low Pass Filter. The final output signal is routed to the blindmate RF output connector. (800 MHz QUAD and 900 MHz QUAD PAs)■Contains an RF coupler that provides an RF feedback signal to the Exciter via a blindmate RF connector on the DC/Metering Board. Also contains a forward and reverse power detector for alarm and power monitoring purposes.■Contains the thermistor that senses PA temperature and feeds the signal back to the DC/Metering Board for processing (40W-800 MHz, 70W-800 MHz)Fan Assembly ■Consists of three fans used to keep the PA within predetermined operating temperaturesDC Core Board(QUAD+2 only)■Provides Non-volatile memory (NVM) to store unique power amplifier calibration information■Provides Gain and FB power control■Provides Diagnostic sensors■Provides Digital interface to the rest of the base radio■Provides Cooling measures control■Provides Status LEDsDriver Board(QUAD+2 only)■Amplifies the output RF signal from the transceiver module (via the core board) to an intermediate power level■Provides first two stages of RF amplificationFinal Board(QUAD+2 only)■Amplifies the output RF signal from the driver board (via the distribution board).■Provides last two stages of RF amplificationIsolator Board(QUAD+2 only)■Provides proper RF loading to the final moduleLow Pass Filter Board(QUAD+2 only)■Reduces harmonic power levels conducted through the PA RF output connector to acceptable levelsTable 5-2 Power Amplifier Circuitry  (continued) Circuit Description
Power Amplifier Volume 2PA Theory of OperationEnhanced Base Transceiver System (EBTS)5-10 68P80801E35-E 16-June-06DC/Metering Board Non-QUAD PAThe DC/Metering Board provides the interface between the PA and the Base Radio backplane.  The preamplified/modulated RF signal is input directly from the Exciter via the Base Radio backplane. The RF input signal is applied to the input of the Linear Driver Module (LDM). The RF feedback signal is fed back to the Exciter, where it is monitored for errors. The primary function of the DC/Metering Boards is to monitor proper operation of the PA.  This information is forwarded to the Base Radio Controller (BRC) via the SPI bus.  The alarms diagnostic points monitored by the BRC on the PA include the following:■Forward power■Reflected power■PA temperature sense■Fan SensorQUAD PA OnlyThe DC/Metering Board in the QUAD Radio serves the same function as it does in other radios. However, its circuitry is modified for compatibility with the QUAD Station. As a result, its logic circuitry is operated at 3.3 VDC.In addition to the functions listed for non-QUAD versions above, the following meter points are ported to the SPI bus:■A and B Currents■Thermistor (for PA temperature sensing circuit on the DC/Metering Board)■Voltage Variable Attenuator Circuit (900 MHz QUAD version)■PA Bias Enable Circuitry (900 MHz QUAD version)Null Board(QUAD+2 only)■Provides +28Vdc to the Distribution BoardDistribution Board(QUAD+2 only)■Provides all signal routing from the Core and Null Boards to that of the Final and Low Pass Filter boardsNote *  The power outputs described in this section for the 800 QUAD and 900 QUAD PAs are references to the single carrier mode operating at 52W average power out from the PA output connector.Table 5-2 Power Amplifier Circuitry  (continued) Circuit Description
Volume 2 Power AmplifierPA Theory of OperationEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-11Linear Driver Module 40W-800 MHz, 70W-800 MHZ and 800 MHZ QUAD PAsThe Linear Driver Module (LDM) amplifies the low-level RF signal from the Exciter.  The LDM consists of a two-stage cascaded Class AB amplifier, with the final stage in a parallel configuration. See Table 5-2 for the approximate input and output levels of the various LDMs. The LDM output is fed to the RF Splitter/DC Distribution Board via an Interconnect Board.900 QUAD PAThe Linear Driver Module (LDM) amplifies the low-level RF signal from the Exciter. The LDM consists of a three stage, cascaded, Class AB amplifier, with the final stage in a parallel configuration. See Table 5-2 for the approximate input and output power of the 900 MHz QUAD LDM. The LDM Output is fed to the RF Splitter/DC Distribution Board via the Interconnect Board.Interconnect Board The output of the LDM is applied to the Interconnect Board, which provides an RF connection to the RF Splitter/DC Distribution Board.  As a separate function, area on the Interconnect Board serves as a convenient mounting location for electrolytic capacitors used for filtering the +28 VDC supply. RF Splitter/DC Distribution BoardThe RF Splitter portion of this board accepts the amplified signal from the LDM (via the Interconnect Board).  The primary function of this circuit is to split the RF signal into drive signals for the LFMs. In the 40W-800 MHz PA, this circuit splits the drive signal into three separate paths to be applied to the three LFMs, where the signals will be amplified further.  In the 70W-800 MHz, 800 MHz QUAD and 900 MHZ QUAD PAs, this circuit splits the drive signal into six separate paths to be applied to the six LFMs, where the signals will be amplified further.The DC Distribution portion of this board interfaces directly with the DC/Metering Board to route DC power to the LFMs and provide PA Bias Enable (900 MHz QUAD only)
Power Amplifier Volume 2PA Theory of OperationEnhanced Base Transceiver System (EBTS)5-12 68P80801E35-E 16-June-06Linear Final Modules The RF Splitter output signals are applied directly into the LFMs for final amplification.  Each LFM contains a coupler that splits the LFM input signal and feeds the parallel Class AB amplifiers that amplify the RF signals. In the 40W PA, the amplified signals are then combined on the LFM and sent directly to the RF Interconnect Board. In the 70W PA, the amplified signals are then combined on the LFM and sent directly to the Combiner Board.See Table 5-2 for the approximate total summed output powers of the various LFMs, before output losses.RF Interconnect Board 40W- 800 MHz PA OnlyThe RF Interconnect Board consists of transmission line paths which route the three output signals from the LFMs to the three inputs of the RF Combiner/Peripheral Module.Combiner Board The Combiner Board combines pairs of signals into single signals, thereby combining the six signals from the LDMs into three signals.  The resulting three signals are applied to the RF Combiner/Peripheral Module.RF Combiner/Peripheral Module40- 800 MHz, 70W- 800 MHz PAsThis module consists of two portions: an RF combiner and a peripheral module.  The RF Combiner portion of the module combines the three RF signals from the RF Interconnect Board (40W- 800 MHz PA) or the Combiner Board (70W- 800 MHz PA) into a single signal using a Wilkinson coupler arrangement. Following the combiner circuit, the single combined RF signal is then passed through a directional coupler which derives a signal sample of the LFM RF power output.  Via the coupler, a sample of the RF output signal is fed to the Exciter, via the DC/Metering Board, as a feedback signal.  Following the coupler, the power output signal is passed through a single stage circulator, which protects the PA in the event of high reflected power. The peripheral portion of the module provides a power monitor circuit that monitors the forward and reflected power of the output signal.  This circuit furnishes the A/D converter on the DC/Metering Board with input signals representative of the forward and reflected power levels.
Volume 2 Power AmplifierPA Theory of OperationEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-13For forward power, a signal representative of the measured value is sent to the BRC via the SPI bus.  The BRC determines if this level is within tolerance of the programmed forward power level.  If the level is not within parameters, the BRC will issue a warning to the site controller which, in turn, will shut down the Exciter if required.Reflected power is monitored in the same manner.  The BRC uses the reflected power to calculate the voltage standing wave ratio (VSWR).  If the VSWR is determined to be excessive, the forward power is rolled back.  If it is extremely excessive, the BRC issues a shut-down command to the Exciter.A thermistor is located on the RF Combiner/Peripheral module to monitor the operating temperature of the PA.  The thermistor signal indicating excessive temperature is applied to the A/D converter and then sent to the BRC. The BRC issues a cut-back command to the Exciter module if the monitored temperature is greater than 185° F (85° C).800 MHz QUAD and 900 MHz QUADThis module consists of two parts: an RF combiner and a Peripheral module. The RF combiner combines three RF signals from the Combiner Board into a single signal using a Wilkinson coupler arrangement. Following the combiner circuit, the single combined RF signal is then passed through a directional coupler, which derives a signal sample of the LFM RF power output. Via the coupler, a sample of the RF output signal is fed to the Exciter, via the DC/Metering Board, as a feedback signal. Following the coupler, the power output signal is passed through a dual stage circulator, which protects the PA in the event of high reflected power.The Peripheral module provides a power monitor circuit that monitors the forward and reflected power of the output signal. This circuit furnishes the A/D converter on the DC/Metering Board with input signals, representative of the forward and reflected power levels. For forward power, a signal representative of the measured value is sent to the BRC via the SPI bus. The BRC determines if this level is within tolerance of the programmed forward power level. If the level is not within tolerance, the BRC will issue a warning to the site controller, which, in turn, will shut down the Exciter, if required.Reflected power is monitored in the same manner. The BRC uses the reflected power to calculate the voltage standing wave ratio (VSWR). If the VSWR is calculated as excessive, forward power is rolled back. If the VSWR calcu-lation is exceedingly out of tolerance, the BRC issues a shut-down command to the Exciter.The Thermistor that monitors the operating temperature of the 800 MHZ QUAD and 900 MHz QUAD PAs is located on the DC/Metering Board
Power Amplifier Volume 2PA Theory of OperationEnhanced Base Transceiver System (EBTS)5-14 68P80801E35-E 16-June-06Fan Module The PA contains a fan assembly to maintain normal operating temperature through the use of a cool air intake.  The fan assembly consists of three individual fans in which airflow is directed across the PA heatsink.  The current draw of the fans is monitored by the DC/Metering Board.  A voltage representative of the current draw is monitored by the BRC.  The BRC flags the iSC if an alarm is triggered.  The PA LED on the front panel of the BRC also lights, however the PA does not shut down due to a fan failure alone.DC Core Board (QUAD+2)The Core Board communicates with the other base radio modules as well as internal PA modules. It utilizes non-volatile memory (NVM) via an EEPROM to store unique PA calibration information.Driver Board (QUAD+2)The Driver Amplifier Board provides the first two stages of RF amplification within the PA. It accepts the output RF signal from the transceiver module (via the core board) and amplifies it to an intermediate power level. The Driver Amplifier Board also provides:■Gain compensation over temperature.■On-board DC regulation.■Transmitter standby functionalityFinal Board (QUAD+2)The Final Amplifier Board provides the last two stages of RF amplification, including the second RF gain stage (parallel stage). QUAD+2 utilizes two Final Amplifier Boards.:■RF power splitting (4–way)■RF power combining (4–way)■Diagnostics■Transmitter standby functionalityIsolator Board (QUAD+2)The Isolator provides proper RF loading to the final module output regardless of the load presented to the output of the PA itself. The Isolator contains a load resistor to dissipate any reflected power caused by load mismatches at the output of the PA.
Volume 2 Power AmplifierPA Theory of OperationEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 5-15Low Pass Filter (LPF) Board (QUAD+2)The LPF Board reduces harmonic power levels conducted through the PA RF output connector to acceptable levels. The LPF Board has forward and feedback RF power detectors to monitor forward and reflected output power from the PA, in reference to its output connector. It has a single stage isolator that provides > 20dB isolation with < 0.35dB insertion loss. It also provides a low pass filter with < 0.54dB of in-band insertion loss. Null Board (QUAD+2)The Null Board provides the +28Vdc supply routing from the Core board to the Distribution board (which routes it to the Final board). It also provides the necessary bulk capacitance that is warranted by the Final board.Distribution Board (QUAD+2)The Distribution Board provides for all signal routing from the Core and the Null boards to the Final and LPF boards: ■RF signal from the driver module is split and provided as the input to each of the two final modules.■RF output from both of the final modules is combined to a single path and provided as the input to the isolator.■RF power is coupled off the combined port and fed back to the XCVR■DC Power routing from the NULL board to the Final board■Forward and reverse DC signaling from the LPF board
Power Amplifier Volume 2Enhanced Base Transceiver System (EBTS)5-20 68P80801E35-E 16-June-06Figure 5-8 900 MHz QUAD Power Amplifier Functional Block Diagram COMBINER BOARDLINEAR DRIVER MODULELINEAR FINALMODULES50 OHMLOADADDRESS BUSFROM BRCSPI BUSTO/FROM BRCADDRESS DECODE, MEMORY,& A/D CONVERTER CIRCUITRYMEMORYA/DCONVERTERBOARD SELECTDECODECIRCUITRYPA TEMP SENSECHIPSELECTCHIP SELECTDECODECIRCUITRYCHIP SELECTRF COMBINER/PERIPHERAL MODULELOW-PASSFILTERRF INPUTRF OUTTO ANTENNARF FEEDBACKTO EXCITERMODULEREF PWRFWD PWRFAN SENSEFAN ASSEMBLYTEMPERATURESENSOREBTS417_900121701JNMCLK/DATACIRCULATOR50 OHMLOAD50 OHMLOAD50 OHMLOAD50 OHMLOAD50 OHMLOAD50 OHMLOADSTAGE 2CLASS ABRF SPLITTER/DC DISTRIBUTION BOARDINTERCONNECTBOARDSTAGE 3CLASS ABDCFILTER+28 VDCCIRCULATOR50 OHMLOAD50 OHMLOAD50 OHMLOAD50 OHMLOAD50 OHMLOADEEPOTSTAGE 2CLASS ABDISTRIBUTEDSTAGE 1CLASS ABDISTRIBUTEDC_EINCV_DVVAPA_ENABLE (PA_E)PA_E PA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_EPA_E
Power Supply Volume 2OverviewEnhanced Base Transceiver System (EBTS)6-2 68P80801E35-E 16-June-06Overview 6This section provides technical information for the DC Power Supply (PS).FRU Number to Kit Number Cross ReferenceDC Power Supply Field Replaceable Units (FRUs) are available for the iDEN EBTS. The FRU contains the Power Supply kit and required packaging. Table 6-1 provides a cross reference between Exciter FRU numbers and kit numbers. Table 6-1 FRU Number to Kit Number Cross ReferenceDescriptionFRU NumberKit NumberSingle Channel DC Power Supply  TLN3338 CPN1027QUAD Channel DC Power Supply CLN1498 CLN1461QUAD+2 Channel DC Power Supply DLN6568 CPN1081
Power Supply Volume 2DC Power Supply for QUAD Channel Base RadiosEnhanced Base Transceiver System (EBTS)6-6 68P80801E35-E 16-June-06DC Power Supply for QUAD Channel Base Radios 6QUAD Channel DC Power Supply OverviewThe QUAD Channel DC Power Supply provides DC operating voltages to QUAD Channel Base Radio FRUs. The power supply accepts input voltage sources from 41VDC to 60VDC. Input sources may be either positively or negatively grounded.On initial startup, the supply requires a nominal 43 VDC. If the voltage drops below 41 VDC, the QUAD Channel DC Power Supply enters quiescent mode. In quiescent mode, the power supply emits no power.The QUAD Channel DC Power Supply is designed for sites with an available DC voltage source. Output voltages from the DC Power Supply are 28.6 VDC, 14.2 VDC and 3.3 VDC, with reference to output ground. The supply is rated for 575 Watts of continuous output, with up to 113° F (45° C) inlet air. At 140° F (60° C), the 28.6 VDC output reduces to 80% of maximum. The QUAD Channel DC Power Supply consists of the Power Supply and front panel hardware. The QUAD Channel DC Power Supply connects to the chassis backplane through an edgecard connector. Two Torx screws on the front panel secure the QUAD Channel DC power supply to the chassis.Figure 6-2 shows the QUAD Channel Power Supply with the cover removed.Figure 6-2 Quad Carrier Power Supply
Volume 2 Power SupplyDC Power Supply for QUAD Channel Base RadiosEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E 6-7QUAD Channel DC Power Supply Controls and IndicatorsTable 6-5 summarizes LED indications on the QUAD Channel DC Power Supply during normal operation. The ON/OFF switch behind the front panel turns DC power supply on and off.QUAD Channel DC Power Supply Performance Specifications Table 6-6 lists the specifications for the QUAD Channel DC Power Supply.Table 6-5 DC Power Supply IndicatorsLED Condition IndicationsGreenSolid (on) Power Supply is on, and operating under normal conditions with no alarmsOff Power Supply is turned off or required power is not availableRedSolid (on) Power Supply fault or load fault on any output, or input voltage is out of rangeOff Power Supply is operating normally, with no alarmsTable 6-6 DC Power Supply Specifications Description Value or RangeOperating Temperature 0° to +40° C (no derating)+41° to +60° C (derating)Input Voltage 41 to 60 VDCInput Polarity Positive (+) ground systemStartup Voltage 43 VDC (minimum)Input Current 18.0 A (maximum) @ 41 VDCSteady State Output Voltages28.6 VDC +5%14.2 VDC +5%3.3 VDC +5%Total Output Power Rating 575 W (no derating)485 W (derating)
Power Supply Volume 2DC Power Supply for QUAD Channel Base RadiosEnhanced Base Transceiver System (EBTS)6-8 68P80801E35-E 16-June-06QUAD Channel DC Power Supply Theory of OperationTable 6-7 briefly describes the basic DC Power Supply circuitry. Figure 6-6 shows the functional block diagrams for the DC Power Supply.Output RippleAll outputs 150mV p-p (measured with 20 MHz BW oscilloscope at 25°C)High Frequency individual harmonic voltage limits (10kHz to 100MHz) are:28.6 VDC 1.5 mV p-p14.2 VDC  3.0 mV p-p3.3 VDC 5.0 mV p-pShort Circuit Current 0.5 A average (maximum)Table 6-6 DC Power Supply Specifications  (continued)Description Value or RangeTable 6-7 DC Power Supply Circuitry Circuit DescriptionInput CircuitRoutes input current from the DC power input cable through the high current printed circuit edge connector, EMI filter, panel mounted combination circuit breaker, and on/off switchStartup Inverter CircuitryProvides VDC for power supply circuitry during initial power-upMain Inverter Circuitry Consists of a switching-type power supply to generate the +28.6 VDC supply voltageTemperature ProtectionThe Power Supply contains a built-in cooling fan that runs whenever the supply is powered on. The supply shuts down if the temperature exceeds a preset threshold+14.2 VDC Secondary Converter CircuitryConsists of a switching-type power supply to generate the +14.2 VDC supply voltage+3.3 VDC Secondary Converter CircuitryConsists of a switching-type power supply to generate the +3.3 VDC supply voltageClock Generator CircuitryGenerates the 267 kHz and 133 kHz clock signals used by the pulse width modulators in the four inverter circuitsAddress Decode, Memory, & A/D ConverterServes as the main interface between A/D on the Power Supply and the BRC via the SPI bus
Volume 2 Power SupplyEnhanced Base Transceiver System (EBTS)16-June-06  68P80801E35-E 6-17Figure 6-6 QUAD DC Power Supply Functional Block Diagram (Sheet 1 of 2) +5.1 V INVERTER CIRCUITRYFETDRIVERPOWER FETSWITCH FILTERCIRCUITRYVCCVCC+ 5V OVERCURRENTDETECTREFREFSURGE CURRENTDELAY REFOVERVOLTAGEDETECTFETCROWBARCIRCUIT+ 28V BULKPULSEWIDTHMODULATORA24253031+5.1 V DCTOSTATIONMODULESVIABACKPLANEP/OBACKPLANECONNECTOR+5.1 V÷2CLOCK GENERATOR CIRCUITRYSTARTUP INVERTER CIRCUITRYBULK DETECTTODIAGNOSTICSCIRCUITRYPULSEWIDTHMODULATORVCCVCC STARTUP ISOLATIONTRANSFORMER+14.2 V INVERTER CIRCUITRYFETDRIVERPOWER FETSWITCH FILTERCIRCUITRYVCCVCC+ 14.2V OVERCURRENTDETECTREFREFSURGE CURRENTDELAY REFOVERVOLTAGEDETECTFETCROWBARCIRCUITA16172223+14.2V DCTOSTATIONMODULESVIABACKPLANEP/OBACKPLANECONNECTOR+14.2V+14.2VPULSEWIDTHMODULATORPULSEWIDTHMODULATORFRONT PANELON / OFFSWITCHEXTERNALDC INPUT41-60 VDCFILTERCIRCUITRYINPUT FILTER BOARD341415+28.6 VDCTOSTATIONMODULESVIABACKPLANEP/OBACKPLANECONNECTORMAIN INVERTER CIRCUITRYREFREFCURRENTDETECT A+28.6 V  OVERVOLTAGEDETECT+28 V BULK TODIAGNOSTICSCIRCUITRYOVERCURRENTDETECT+28.6 VDCCLOCKGENERATORCIRCUITRY267 KHZTRANSISTORSWITCHBMAIN ISOLATIONTRANSFORMERTRANSISTORDRIVERSSOFTSTARTCIRCUITRYSHUTDOWNA+12V STARTUP BIAS+12V STARTUP BIASVCCVCCMOD FAIL133 KHZ267 KHZ133 KHZ133 KHZ133 KHZ133 KHZ133 KHZ267 KHZ133 KHZ267 KHZ133 KHZPOWER FETSWITCHES FILTERINGCIRCUITRY+28 V BULKEBTS323011497JNM
Power Supply Volume 2Enhanced Base Transceiver System (EBTS)6-18 68P80801E35-E 16-June-06Figure 6-7 QUAD DC Power Supply Functional Block Diagram (Sheet 2 of 2) A/DCONVERTERCOOLINGFANTHERMISTORMOUNTED ONHEATSINKSPI BUSREFREFREFMOD FAILINPUT FAILHEATSINK DIAG+5.1 V+14.2V DIAG+5.1 V DIAG+28.6 V DIAGREFREFHEATSINK STATUSDETECTHI-TEMPDETECTBULK DETECTFROM STARTUPINVERTERCIRCUITRYFROMDETECTCIRCUITRYABINPUT GOOD(GREEN)MODULEFAIL(RED)3SPI BUSTO/FROMSTATION CONTROLMODULEADDRESS DECODE CIRCUITRYADDRESSDECODECIRCUITRYFROMSTATIONCONTROLBOARD9P/O ADDRESS BUS ENABLE ENABLEDIAGNOSTICS CIRCUITRYT°EBTS324012097JNMJ300REF
Troubleshooting Volume 2OverviewEnhanced Base Transceiver System (EBTS)8-2 6880801E35-E 22-Mar-06OverviewThis chapter is a guide for isolating Base Radio failures to the FRU level. There are three sections- one each for Legacy Single Channel Base Radios, Generation 2 Single Channel Base Radios, QUAD Channel Base Radios and QUAD+2 Channel Base Radios. Each section contains procedures for:nTroubleshootingnVerification/Station OperationThe maintenance philosophy for any Base Radio is to repair by replacing defective FRUs with new FRUs. This method limits down-time.Two troubleshooting procedures are included. Each procedure is designed to quickly identify faulty FRUs.Ship defective FRUs to a Motorola repair depot for repair.Note Any product damage resulting from improperly packaged equipment will not be covered under the standard Motorola warranty agreement.
Volume 2 TroubleshootingTroubleshooting PreliminariesEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-3Troubleshooting PreliminariesRecommended Test EquipmentTable 8-1 lists recommended test equipment necessary for performing Base Radio troubleshooting/verification procedures.Troubleshooting ProceduresMany of the troubleshooting and station operation procedures require Man-Machine Interface (MMI) commands. These commands are used to commu-nicate station level commands to the Base Radio via the RS-232 communica-tions port located on the front of the BRC. Table 8-1 Recommended Test EquipmentEquipment Model/Type Manufacturer DescriptionService Computer † 80286 or better IBM, IBM compatible, or MacintoshLocal service computer with a Serial PortApplication Code n/a Motorola Compressed application code for Gen 3 SC and BRCCommunication SoftwareProComm PlusHyperTerminalSymantecWindows 95/98/2000/XP Host communicationRS-232 Cable n/a Locally ProcuredStraight through connecting cable with DB9 connector for BRC portRF Attenuator,250W, 10dB01-80301E7258-45-33MotorolaAeroflex / WeinschelUsed to attenuate receive signals for testingRF Power Meter†† HP438AE4418Hewlett-PackardAgilentUsed to perform relative calibration and linearity checks of signal sourceLow-Power Sensor HeadHP8481DE9301Hewlett-PackardAgilentUsed in conjunction with Power MeterRubidium Frequency Standard RubiSource Symmetricom Used as a frequency standard for receive testiDEN Test Set R2660 Motorola Used for checking receive operationNote † Either a DOS-based computer or Macintosh computer may be used for the service computer. Contact your iDEN System Manager for additional information.†† Do not substitute analog power meter (such as HP435A). Analog power meter averaging time is not long enough to accurately read pulsed iDEN signal.
Troubleshooting Volume 2Troubleshooting PreliminariesEnhanced Base Transceiver System (EBTS)8-4 6880801E35-E 22-Mar-06Routine CheckoutProcedure One is a quick, non-intrusive test performed during a routine site visit. Use this procedure to verify proper station operation without taking the station out of service. Figure 8-1 shows the Procedure One Troubleshooting Flowchart.Figure 8-1 Procedure One Troubleshooting Flowchart PROCEDURE 1ROUTINESITE VISITOBSERVE LEDINDICATORSModule Suspectedof Being Faulty?NoNoDONECHECK CURRENTALARM STATUSUse MMI commandget alarmsto check alarm statusModule Suspectedof Being Faulty?Ye sGo to TroubleshootingProcedure 2 Flow ChartYe sGo to TroubleshootingProcedure 2 Flow ChartRefer toControls and Indicatorsfor LED DefinitionsEBTS021071895JNM
Volume 2 TroubleshootingTroubleshooting PreliminariesEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-5Reported/Suspected ProblemUse Procedure Two to troubleshoot reported or suspected equipment malfunc-tions. Perform this procedure with equipment in service (non-intrusive) and with equipment taken temporarily out of service (intrusive).Figure 8-2 shows the Procedure Two Troubleshooting Flowchart.Figure 8-2 Procedure Two Troubleshooting Flowchart PROCEDURE 2PROBLEMREPORTED OR SUSPECTEDDONEClear Problem ReportOBSERVE LEDINDICATORSModule Suspectedof Being Faulty?Ye s Go to Module ReplacementProcedures SectionNoCHECK CURRENTALARM STATUSUse MMI commandget alarmsto check alarm statusModule Suspectedof Being Faulty? Go to Module ReplacementProcedures SectionPERFORMVERIFICATION TESTSUse MMI commands toperform tests as specified instation verification procedure.Module Suspectedof Being Faulty? Go to Module ReplacementProcedures SectionYe sNoYe sNoRefer toControls and Indicatorsfor LED DefinitionsEBTS022071895JNM
Troubleshooting Volume 2QUAD Channel Base Radio/Base Radio FRU Replacement ProceduresEnhanced Base Transceiver System (EBTS)8-82 6880801E35-E 22-Mar-06QUAD Channel Base Radio/Base Radio FRU Replacement ProceduresReplace suspected station modules with known non-defective modules to restore the station to proper operation. The following procedures provide FRU replacement instructions, post-replacement adjustments and verification instructions.QUAD Base Radio Replacement ProcedureNote Base Radio removal and installation procedures appear for reference or buildout purposes. Field maintenance of Base Radios typically consists of replacement of FRUs within the Base Radio. Perform Base Radio FRU replacement according to “Base Radio FRU Replacement Procedure” below.Perform Base Radio (BR) replacement as described in the following paragraphs.Ì!CAUTIONImproper lifting or dropping the BR could result in serious personal injury or equipment damage.Base Radios are HEAVY!Handle the BR with extreme caution, and according to local health and safety regulations.RemovalRemove the BR from the Equipment Cabinet as follows:Ì!CAUTIONA Single Carrier BR can weigh up to 76 LBS (34 KG). A QUAD Carrier BR can weigh up to 91 LBS (41 KG). Handle the BR with extreme caution, and according to local health and safety regulations.1. Remove power from the Base Radio by setting the Power Supply ON/OFF switch to the OFF position.2. Tag and disconnect the cabling from the BR rear panel connectors.
Volume 2 TroubleshootingQUAD Channel Base Radio/Base Radio FRU Re-Enhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-833. Remove the Power Amplifier module to reduce the BR weight. Remove the two M10 Torx screws that secure the Power Amplifier module. Slide the module out of the chassis.4. Remove the four M30 TORX screws which secure the BR front panel to the Equipment Cabinet mounting rails.5. While supporting the BR, carefully remove the BR from the Equipment Cabinet by sliding the BR from the front of cabinet. When the BR becomes free from its mounting rails, be sure to fully support it.InstallationInstall BR in Equipment Cabinet as follows:Ì!CAUTIONA Single Carrier BR can weigh up to 76 LBS (34 KG). A QUAD Carrier BR can weigh up to 91 LBS (41 KG). Handle the BR with extreme caution, and according to local health and safety regulations.1. If adding a BR, install side rails in the appropriate BR mounting position in the rack.2. Remove the Power Amplifier module to reduce the BR weight. Remove the two M10 Torx screws that secure the Power Amplifier module. Slide the module out of the chassis.3. While supporting the BR, carefully lift and slide the BR in the Equipment Cabinet mounting position.4. Secure the BR to the Equipment Cabinet mounting rails using four M30 Torx screws. Tighten the screws to 40 in-lb (4.5 Nm).5. Slide the Power Amplifier module back into the BR chassis. Replace two M10 Torx screws that secure the Power Amplifier module. Secure the module by tightening the screws to the specified torque of 5 in-lbs.6. Connect the cabinet cabling to the BR. Refer to Backplane figure XX.7. Perform BR activation as described below.Note Base Radio removal and installation procedures appear for reference or buildout purposes. Field maintenance of Base Radios typically consists of replacement of FRUs within the Base Radio. Perform Base Radio FRU replacement according to “Base Radio FRU Replacement Procedure” below.
Troubleshooting Volume 2QUAD Channel Base Radio/Base Radio FRU Replacement ProceduresEnhanced Base Transceiver System (EBTS)8-84 6880801E35-E 22-Mar-06Anti-Static PrecautionsCAUTIONThe Base Radio contains static-sensitive devices. Prevent electrostatic discharge damage to Base Radio modules! When replacing Base Radio FRUs, wear a grounded wrist strap. Observe proper anti-static procedures.Motorola publication 68P81106E84 provides complete static protection infor-mation. This publication is available through Motorola National Parts. Observe the following additional precautions:nWear a wrist strap (Motorola Part No. 4280385A59 or equivalent) at all times when servicing the Base Radio to minimize static build-up.nA grounding clip is provided with each EBTS cabinet. If not available, use another appropriate grounding point.nDO NOT insert or remove modules with power applied to the Base Radio. ALWAYS turn the power OFF using the Power Supply rocker switch on the front of the Power Supply module.nKeep spare modules in factory packaging for transporting. When shipping modules, always pack in original packaging.QUAD BRs Radio FRU Replacement ProcedurePerform the following steps to replace any of the Base Radio FRUs:Note After a Control Board or BR replacement, the integrated Site Controller (iSC) reboots the BR. Whenever the BR goes off-line, the Replacement BRC Accept Timer begins counting down. A BR reboot occurs if the BR remains off-line as the timer times out. (The timer’s default period is three minutes.) If someone turns on the BR before the timer times out, power down the BR. Then wait for the minimum timer period before turning on the BR.1. Notice the Power Supply rocker switch, behind the front panel of the Power Supply. Set the Power Supply rocker switch to the OFF (0) position. Turning off this switch removes power from the Base Radio.2. Loosen the front panel fasteners. These are located on each side of the module being replaced.3. Pull out the module.4. Insert the non-defective replacement module by aligning the module side rails with the appropriate rail guides inside the Base Radio chassis. 5. Gently push the replacement module completely into the Base Radio chassis assembly using the module handle(s).
Volume 2 TroubleshootingQUAD Channel Base Radio/Base Radio FRU Re-Enhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-85CAUTIONDO NOT slam or force the module into the chassis assembly. Rough handling can damage the connectors or backplane.6. Secure the replacement module by tightening the front panel fasteners to the specified torque of 5 in-lbs.7. Apply power to the Base Radio by setting the switch to the ON position.8. Perform the Station Verification Procedure.QUAD BR Power Amplifier (PA) Fan FRU ReplacementPerform the following steps to replace the Power Amplifier (PA) fans.1. Remove the Power Amplifier from the Base Radio per FRU Replacement Procedure.2. Disconnect fan power cable from PA housing.3. Remove front panel from fan assembly.4. Remove fan assembly from PA chassis. Note To install the new fan kit, reverse above procedure.
Troubleshooting Volume 2QUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)8-86 6880801E35-E 22-Mar-06QUAD Base Radio Station Verification ProceduresPerform the Station Verification Procedures whenever you replace a FRU. The procedures verify transmit and receive operations. Each procedure also contains the equipment setup.QUAD BR Replacement FRU VerificationBefore shipment, the factory programs all module-specific information. Base Radio specific information (e.g., receive and transmit frequencies) involves a download to the Base Radio from the network/site controller.The Base Radio does not require replacement FRU alignment. QUAD BR Base Repeater FRU Hardware Revision VerificationNote The following procedure requires the Base Radio to be out of service. Unless the Base Radio is currently out of service, Motorola recommends performing this procedure during off-peak hours. Performing this procedure then minimizes or eliminates disruption of service to system users.1. Connect one end of the RS-232 cable to the service computer.2. Connect the other end of the RS-232 cable to the STATUS port, located on the front panel of the EX/CNTL module.3. After the BR is powered up using the front switch on the Power Supply Module, press the reset button on the Control Module front panel. At the prompt, hit a Carriage Return on the service computer to enter the test application mode. Using the field password, log in to the BR.To enter field mode, at the > prompt type login -ufield.After entering the correct field password, the field> prompt is displayed on the service computer.The default factory set field password is motorola.Note The ‘Out of Box’ default factory set field password is deleted and is replaced by the customer defined field password contained within the OMC. This occurs as soon as the controller module receives its initial OMC download.The default OMC set field password is Motorola.
Volume 2 TroubleshootingQUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-87Note The OMC field password is customer configurable. Please contact the Operations and Maintenance Center (OMC) operator on duty to obtain your customer unique field password.Note Future versions of the QUAD BR will ship with software that recognizes the BR cabinet position. Default Motorola Manufacturing BR programmed cabinet position is (0,0), which automatically sends the radio to Test Application software mode upon power up. Upon setting a valid cabinet position, the radio will default to the Call Processing mode of operation.4. Collect revision numbers from the station by typing the following command:5. If all modules return revision numbers of the format “Rxx.xx.xx”, then all revision numbers are present. In that case, verification requires no further action. If revision numbers return as blank, or not in the format “Rxx.xx.xx”, contact your local Motorola representative or Technical Support.6. Set desired cabinet id, position, and of BR by typing the following commands, with the final number on each command being the desired cabinet id and position. The command example below sets cabinet id to 5, and cabinet position to 2.7. After checking all BRs, log out by keying the following command:Note To start Call Processing mode of operation, reset the Base Radio using the front panel switch.field>login -ufieldpassword:<login password>field>field>fv -oplatformfield>field>ci -oplatform -c5field>pi -oplatform -p2field>field> logout
Troubleshooting Volume 2QUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)8-88 6880801E35-E 22-Mar-06QUAD BR Transmitter VerificationThe transmitter verification procedure verifies the transmitter operation and the integrity of the transmit path. This verification procedure is recommended after replacing an Exciter, Power Amplifier, BRC, or Power Supply module.Note The following procedure requires the Base Radio to be out of service. Unless the Base Radio is currently out of service, Motorola recommends performing this procedure during off-peak hours. This minimizes or eliminates disruption of service to system users.Equipment SetupTo set up the equipment, use the following procedure:1. Remove power from the Base Radio by setting the Power Supply rocker switch (located behind the front panel of the Power Supply) to the OFF (0) position.2. Connect one end of the RS-232 cable to the service computer.3. Connect the other end of the RS-232 cable to the STATUS port located on the front panel of the BRC. Ì!CAUTIONMake sure power to BR is OFF before disconnecting transmitter RF connectors. Disconnecting transmitter RF connectors while the BR is keyed may result in RF burns from arcing.4. Disconnect the existing cable from the connector labeled PA OUT. This connector is located on the backplane of the Base Radio.5. Connect a test cable to the PA OUT connector.6. Connect a 10 dB attenuator (100 W or more average power dissipation) on the other end of the test cable.7. From the attenuator, connect a cable to the RF IN/OUT connector on the R2660 Communications Analyzer.8. Remove power from the R2660 and connect the Rubidium Frequency Standard 10MHZ OUTPUT to a 10 dB attenuator.9. Connect the other end of the 10 dB attenuator to the 10MHZ REFERENCE OSCILLATOR IN/OUT connector on the R2660.Note Refer to the equipment manual provided with the R2660 for further information regarding mode configuration of the unit (Motorola Part No. 68P80386B72). 10. Set the R2660 to the EXT REF mode.
Volume 2 TroubleshootingQUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-8911. Apply power to the R2660.12. Set the R2660 to the SPECTRUM ANALYZER mode with the center frequency set to the transmit frequency of the Base Radio under test.13. Perform the appropriate transmitter verification procedure below for the particular Power Amplifier used in the Base Radio.Transmitter Verification Procedure(QUAD Carrier 800 MHz and 900 MHz Power Amplifiers)This procedure provides commands and responses to verify proper operation of the transmit path for 800 MHz and 900 MHz QUAD Channel Base Radios. 1. Power on the BR using the front switch on the Power Supply Module. Press the reset button on the Control Module front panel. At the prompt, hit a Carriage Return on the service computer to enter the test application mode. Using the user_id -ufield and the field password, login to the BR.To enter field mode, at the > prompt type login -ufield.After entering the correct field password, the field> prompt is displayed on the service computer.The default factory set field password is motorola.Note The ‘Out of Box’ default factory set field password is deleted and is replaced by the customer defined field password contained within the OMC. This occurs as soon as the controller module receives its initial OMC download.The default OMC set field password is Motorola.Note The OMC field password is customer configurable. Please contact the Operations and Maintenance Center (OMC) operator on duty to obtain your customer unique field password.2. Dekey the BR to verify that no RF power is being transmitted. Set the transmit DSP test mode to “stop.” At the field > prompt, type: field>login -ufieldpassword:<login password>field>
Troubleshooting Volume 2QUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)8-90 6880801E35-E 22-Mar-06Note The following command keys the transmitter. Make sure that transmission only occurs on licensed frequencies or into an RF load. 3. Key the BR to 40 watts, following the steps below from the field > prompt: a) 800 MHz QUAD: Set the frequency of transmit channel 1 through 4. b) 900 MHz QUAD: Set the frequency of transmit channel 1 through 4. c) Enable the channels by setting a data pattern to “iden” field> power -otxch1 -p0 field> ptm -otx_all -mstopfield> dpm -otxch1 -mnonefield> dpm -otxch2 -mnonefield> dpm -otxch3 -mnonefield> dpm -otxch4 -mnonefield> freq -otxch1 -f860field> freq -otxch2 -f860.025field> freq -otxch3 -f860.05field> freq -otxch4 -f860.075field> freq -otxch1 -f935field> freq -otxch2 -f935.025field> freq -otxch3 -f935.05field> freq -otxch4 -f935.075field> dpm -otxch1 -midenfield> dpm -otxch2 -midenfield> dpm -otxch3 -midenfield> dpm -otxch4 -miden
Volume 2 TroubleshootingQUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-91Note After the following command is entered, power will be transmitted at the output of the Power Amplifier.d) Set the transmit power to 40 watts and key the BR.4. After keying the Base Radio, verify the forward and reflected powers of the station along with the station VSWR with the parameters listed in Table 8-41. Note The reported value for forward power are not indicative of Base Radio performance. This value is reported from the internal wattmeter. These limits are only for verification of operation and are not representative of true operational power of the transmitter. a) At the field > prompt, type:This command returns all active alarms of the Base Radio.b) At the field > prompt, type: If the alarms command displays alarms, refer to the System Troubleshooting section of this manual for corrective actions.5. View the spectrum of the transmitted signal on the R2660 Communications Analyzer in the Spectrum Analyzer mode. Figure 8-10 and Figure 8-11 shows a sample of the 800MHz and 900MHz spectrum, respectively. Table 8-41 QUAD BR Transmitter ParametersParameter Value or RangeForward Power Greater than 36 WattsReflected Power Less than 4.0 WattsVSWR Less than 2:1field> ptm -otx_all -mdnlk_framedfield> power -otxch1 -p40field> power -otx_allfield> alarms -ofault_hndlr
Troubleshooting Volume 2QUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)8-92 6880801E35-E 22-Mar-06Figure 8-10 800 MHz QUAD Carrier Spectrum
Volume 2 TroubleshootingQUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-93Figure 8-11 900 MHz QUAD Carrier Spectrum 6. Dekey the BR to verify no RF power is being transmitted. Set the transmit DSP test mode to “stop.” At the field> prompt, type: field> power -otxch1 -p0field> ptm -otx_all -mstopfield> dpm -otxch1 -mnonefield> dpm -otxch2 -mnonefield> dpm -otxch3 -mnonefield> dpm -otxch4 -mnone
Troubleshooting Volume 2QUAD Base Radio Station Verification ProceduresEnhanced Base Transceiver System (EBTS)8-94 6880801E35-E 22-Mar-06Equipment DisconnectionUse the following steps to disconnect equipment after verifying the trans-mitter. 1. Remove power from the Base Radio by setting the Power Supply rocker switch (located behind the front panel of the Power Supply) to the OFF (0) position.2. Disconnect the RS-232 cable from the connector on the service computer.3. Disconnect the other end of the RS-232 cable from the RS-232 connector located on the front panel of the BRC.Ì!CAUTIONMake sure power to BR is OFF before disconnecting transmitter RF connectors. Disconnecting transmitter RF connectors while the BR is keyed may result in RF burns from arcing.4. Disconnect the test cable from the PA OUT connector located on the backplane of the Base Radio.5. Connect the standard equipment cable to the PA OUT connector.6. Disconnect the 10 dB attenuator from the other end of the test cable. 7. From the attenuator, disconnect the cable to the R2660 Communications Analyzer.8. Restore power to the Base Radio by setting the Power Supply rocker switch to the ON (1) position.9. If necessary, continue with the Receiver Verification Procedure.
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-117QUAD Channel BR BackplaneBackplane ConnectorsThe Base Radio backplane includes all external equipment connections. Table 8-42 lists and describes the backplane connectors.Table 8-42 QUAD BR Backplane ConnectorsConnector Module Description Connector TypeP1 EXBRC Signal 168 Pin AMP Z-Pack FuturebusP2 RX1 Signal 72 Pin AMP Z-Pack FuturebusP3  RX1 RF 6 coax Harting HarpakP4 RX2 Signal 72 Pin AMP Z-Pack FuturebusP5 RX2 RF 6 coax Harting HarpakP6 RX3 Signal 72 Pin AMP Z-Pack FuturebusP7 RX3 RF 6 coax Harting HarpakP8 RX4 Signal 72 Pin AMP Z-Pack FuturebusP9 RX4 RF 6 coax Harting HarpakP10 PA Signal 96 Pin EUROP11 PS Signal & Power  78 Pin AMP TeledensityP12*PS -48 Vdc Power In 8 Pin AMP 530521-3P13 EX RF(EX from PA) SMA blindmateP14 EX RF(EX to PA) SMA blindmateP15 External / EXBRC Ethernet BNC blindmateP16 External / PA RF (PA from EX) SMA blindmateP17 External / PA RF (PA to EX) SMA BlindmateP18 External / PA TX Output SMA blindmateP19 RX Branch 1 RF SMA
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-118 6880801E35-E 22-Mar-06Figure 8-14 shows the locations of the QUAD Base Radio external connec-tions.Figure 8-14 QUAD Base Radio Backplane Connectors P20 RX Branch 2 RF SMAP21 RX Branch 3 RF SMAP22** External RS232 Dsub-9P23 External Alarm Dsub-25P24 External 5MHz/1PPS BNCNote * P12 is a cutout in the backplane with threaded inserts for securing the connector which mates directly to the power supply. Note ** P22 will not be placed on the backplane. However, the backplane shall be designed with P22 to allow for reuse on future products.Table 8-42 QUAD BR Backplane ConnectorsConnector Module Description Connector TypeEX OUTPA I NETHERNETPA F BDC POWERAC POWERRS 232 ALARMRX 1(RED)RX 2(GRN)RX 3(YEL)5MHZ/1 PPSPA O U TGROUNDEBTS327Q112501JNMRE BLACKThis port must be terminated by 50Ωload when configured for2 Branch Diversity. Also, the rx_fru_config parameter must be set to R12.**EX FB
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-119QUAD BR Backplane Connector PinoutsTable 8-43 lists the pin-outs for the Base Radio Controller board’s 168-pin P1 connector. Table 8-43 EXBRC P1 Pinout, Signal and PowerRow ABCD1GND 3.3 Vdc3.3 VdcNC2GND 3.3 Vdc 14.2 Vdc 14.2 Vdc3 GND 3.3 Vdc 14.2 Vdc 14.2 Vdc4GND GND GND GND5NCNCNCNC6GND GND GND GND7 GND 16.8MHz_RX 16.8MHz_RX_RTN GND8GND GND GND GND9 GND 5 MHz/1 PPS 3.3 Vdc 3.3 Vdc10 NC NC NC 3.3 Vdc11 TxD CTS DTR BRG12 RTS RxD DSR CD13 NC NC NC 3.3 Vdc14 NC NC SHUTDOWN_ SLEEP_15 PA_ENABLE NC 28.6 Vdc 14.2 Vdc16 NC NC NC 3.3 Vdc17 EXT_GPI_1_ EXT_GPI_2_ EXT_GPO_1_ EXT_GPO_2_18 BAT_STAT_ MTR_STAT_ EXT_VFWD EXT_VREV19 SPI_M3 SPI_M2 SPI_M1 SPI_M020 SPI_ENABLE SPI_MOSI SPI_MISO SPI_CLK21 SPI_A2 SPI_A1 SPI_A0 WP_22 NC RxRESET_ NC NC23 NC Clock_SyncB_ NC NC24 GND GND 3.3 Vdc 3.3 Vdc25 SSI_Data_D SSI_CLK_D SSI_FS_D 3.3 Vdc
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-120 6880801E35-E 22-Mar-0626 SSI_Data_D_RTN SSI_CLK_D_RTN NC 3.3 Vdc27 GND GND 3.3 Vdc 3.3 Vdc28 DSPIb_MOSI DSPIb_CLK DSPIb_EN_1 DSPIb_EN_229 DSPIb_MOSI_RTN DSPIb_CLK_RTN DSPIb_EN_3 NC30 GND GND 3.3 Vdc 3.3 Vdc31 GND SSI_Data_C SSI_CLK_C SSI_FS_C32 GND SSI_Data_C_RTN SSI_CLK_C_RTN NC 33 NC Clock_SyncA_ NC NC34 GND GND 3.3 Vdc 3.3 Vdc35 SSI_Data_B SSI_CLK_B SSI_FS_B 3.3 Vdc36 SSI_Data_B_RTN SSI_CLK_B_RTN NC 3.3 Vdc37 GND GND 3.3 Vdc 3.3 Vdc38 DSPIa_MOSI DSPIa_CLK DSPIa_EN_1 DSPIa_EN_239 DSPIa_MOSI_RTN DSPIa_CLK_RTN DSPIa_EN_3 NC40 GND GND 3.3 Vdc 3.3 Vdc41 GND SSI_Data_A SSI_CLK_A SSI_FS_A42 GND SSI_Data_A_RTN SSI_CLK_A_RTN NCTable 8-43 EXBRC P1 Pinout, Signal and Power (continued)Row ABCDTable 8-44 EXBRC P13 Pinout, Exciter from PACoaxial DescriptionCenter PA INOuter GNDTable 8-45 EXBRC P14 Pinout, Exciter to PACoaxial DescriptionCenter PA FeedbackOuter GND
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-121RX1 ConnectionsTable 8-46 EXBRC P15 Pinout, EthernetCoaxial DescriptionCenter EthernetOuter GNDTable 8-47 RX1 P2 Pinout, Signal and PowerRow ABCD1 NC GND GND Clock_SyncA_2GND DSPIa_MOSI_RTNDSPIa_CLK_RTN DSPIa_EN_13 GND DSPIa_MOSI DSPIa_CLK DSPIa_EN_24GND GND GND GND5 14.2 SSI_CLK_A_RTN SSI_FS_B SSI_CLK_B_RTN614.2 SSI_CLK_A SSI_FS_A SSI_CLK_B7 14.2 GND GND GND814.2 SSI_Data_A_RTN GND SSI_Data_B9 GND SSI_Data_A GND SSI_Data_B_RTN10 GND NC NC NC11 3.3 RxRESET_ GND (ID0) GND (ID1)12 3.3 WP_ SPI_A0 SPI_A113 3.3 SPI_MISO SPI_CLK SPI_A214 GND SPI_M0 SPI_ENABLE SPI_MOSI15 GND SPI_M1 SPI_M2 SPI_M316 GND GND GND NC17 GND 16.8MHz_RX GND NC (WB switch)18 GND 16.8MHz_RX_RTNGND NC (MC switch)
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-122 6880801E35-E 22-Mar-06RX2 ConnectionsTable 8-48 RX1 P3 Pinout, RF Input and Output ConnectionRow A B C D E1 GND - GND - GND2 - RX3_EXP3 -RX1_EXP3 -3 GND - GND - GND4 GND - GND -GND5 - RX2_EXP2 - RX1_EXP2 -6 GND - GND -GND7 GND - GND - GND8 - RX Branch 1 -RX1_EXP1 -9 GND - GND - GNDTable 8-49 RX2 P4 Pinout, Signal and PowerRow ABCD1 NC GND GND Clock_SyncA_2GND DSPIa_MOSI_RTN DSPIa_CLK_RTN DSPIa_EN_33 GND DSPIa_MOSI DSPIa_CLK DSPIa_EN_24GND GND GND GND5 14.2 SSI_CLK_B_RTN NC NC614.2 SSI_CLK_B SSI_FS_B NC7 14.2 GND GND GND814.2 SSI_Data_B_RTN GND NC9 GND SSI_Data_B GND NC10 GND NC NC NC11 3.3 RxRESET_ NC (ID0) GND (ID1)12 3.3 WP_ SPI_A0 SPI_A113 3.3 SPI_MISO SPI_CLK SPI_A214 GND SPI_M0 SPI_ENABLE SPI_MOSI
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-123RX3 Connections15 GND SPI_M2 SPI_M1 SPI_M316 GND GND GND NC17 GND 16.8MHz_RX GND NC (WB switch)18 GND 16.8MHz_RX_RTN GND NC (MC switch)Table 8-49 RX2 P4 Pinout, Signal and Power (continued)Row ABCDTable 8-50 RX2 P5 Pinout, RF Input and Output ConnectionRow A B C D E1 GND - GND - GND2 - RX3_EXP2 -RX2_EXP3 -3 GND - GND - GND4GND - GND - GND5 - RX1_EXP1 - RX2_EXP2 -6GND - GND - GND7 GND - GND - GND8 - RX Branch 2 -RX2_EXP1 -9 GND - GND - GNDTable 8-51 RX3 P6 Pinout, Signal and PowerRow A B C D1 NC GND GND Clock_SyncB_2GND DSPIb_MOSI_RTN DSPIb_CLK_RTN DSPIb_EN_13 GND DSPIb_MOSI DSPIb_CLK DSPIb_EN_24GND GND GND GND5 14.2 SSI_CLK_C_RTN SSI_FS_D SSI_CLK_D_RTN614.2 SSI_CLK_C SSI_FS_C SSI_CLK_D7 14.2 GND GND GND814.2 SSI_Data_C_RTN GND SSI_Data_D
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-124 6880801E35-E 22-Mar-069 GND SSI_Data_C GND SSI_Data_D_RTN10 GND NC NC NC11 3.3 RxRESET_ GND (ID0) NC (ID1)12 3.3 WP_ SPI_A0 SPI_A113 3.3 SPI_MISO SPI_CLK SPI_A214 GND SPI_M2 SPI_ENABLE SPI_MOSI15 GND SPI_M1 SPI_M0 SPI_M316 GND GND GND NC17 GND 16.8MHz_RX GND GND (WB switch)18 GND 16.8MHz_RX_RTN GND NC (MC switch)Table 8-51 RX3 P6 Pinout, Signal and Power (continued)Row A B C DTable 8-52 RX3 P7 Pinout, RF Input and Output ConnectionRow A B C D E1GND-GND-GND2 - RX1_EXP2 -RX3_EXP3 -3GND-GND-GND4GND -GND -GND5 - RX2_EXP1 - RX3_EXP2 -6GND -GND -GND7GND-GND-GND8 - RX Branch 3 -RX3_EXP1 -9GND-GND-GND
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-125RX4 ConnectionsTable 8-53 RX4 P8 Pinout, Signal and PowerRow A B C D1 NC GND GND Clock_SyncB_2GND DSPIb_MOSI_RTN DSPIb_CLK_RTN DSPIb_EN_33 GND DSPIb_MOSI DSPIb_CLK DSPIb_EN_24GND GND GND GND5 14.2 SSI_CLK_D_RTN NC NC614.2 SSI_CLK_D SSI_FS_D NC7 14.2 GND GND GND814.2 SSI_Data_D_RTN GND NC9 GND SSI_Data_D GND NC10 GND NC NC NC11 3.3 RxRESET_ NC (ID0) NC (ID1)12 3.3 WP_ SPI_A0 SPI_A113 3.3 SPI_MISO SPI_CLK SPI_A214 GND SPI_M0 SPI_ENABLE SPI_MOSI15 GND SPI_M3 SPI_M2 SPI_M116 GND GND GND NC17 GND 16.8MHz_RX GND NC (WB switch)18 GND 16.8MHz_RX_RTN GND GND (MC switch)Table 8-54 RX4 P9 Pinout, RF Input and Output ConnectionRow A B C D E1 GND - GND - GND2 - RX1_EXP3 -NC -3 GND - GND - GND4 GND - GND -GND5 - RX2_EXP3 - NC -
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-126 6880801E35-E 22-Mar-06PA Connections6 GND - GND -GND7 GND - GND - GND8 - RX3_EXP1 -NC -9 GND - GND - GNDTable 8-54 RX4 P9 Pinout, RF Input and Output ConnectionRow A B C D ETable 8-55 QUAD BR PA P10 Pinout, Signal and PowerRow ABC1 SPI_ENABLE GND 28.6 Vdc2GND GND 28.6 Vdc3 SPI_A0 GND 28.6 Vdc4GND GND 28.6 Vdc5 SPI_A1 GND 28.6 Vdc6GND GND 28.6 Vdc7 SPI_A2 GND 28.6 Vdc8GND GND 28.6 Vdc9 SPI_M0 GND 28.6 Vdc10 GND GND 28.6 Vdc11 SPI_M1 GND 28.6 Vdc12 GND GND 28.6 Vdc13 SPI_M2 GND 28.6 Vdc14 GND GND 28.6 Vdc15 SPI_M3 GND 28.6 Vdc16 GND GND 28.6 Vdc17 SPI_MISO GND 28.6 Vdc18 GND GND 28.6 Vdc19 SPI_MOSI GND 28.6 Vdc20 GND GND 28.6 Vdc
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-12721 SPI_CLK GND 28.6 Vdc22 GND 3.3 Vdc 28.6 Vdc23 WP* 3.3 Vdc 28.6 Vdc24 GND GND 28.6 Vdc25 PA_ENABLE GND 28.6 Vdc26 GND 14.2 Vdc 28.6 Vdc27 GND 14.2 Vdc 28.6 Vdc28 GND 14.2 Vdc 28.6 Vdc29 GND 14.2 Vdc 28.6 Vdc30 GND 28.6 Vdc 28.6 Vdc31 GND 28.6 Vdc 28.6 Vdc32 GND 28.6 Vdc 28.6 VdcTable 8-55 QUAD BR PA P10 Pinout, Signal and Power (continued)Row ABCTable 8-56 EXBRC P16 Pinout, PA from ExciterCoaxial DescriptionCenter PA INOuter GNDTable 8-57 EXBRC P17 Pinout, PA to ExciterCoaxial DescriptionCenter PA FeedbackOuter GNDTable 8-58 EXBRC P18 Pinout, PA RF OUTCoaxial DescriptionCenter PA RF OUTOuter GND
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-128 6880801E35-E 22-Mar-06External Connections Table 8-59 QUAD BR Backplane Coaxial and DCSignalP12 -48 Vdc PowerP13 EX OutP14 FeedbackP15 EthernetP16 PA InP17 PA FeedbackP18 PA RF OUTP19 RX Branch 1P20 RX Branch 2P21 RX Branch 3P24 5 MHz/1 PPSTable 8-60 QUAD BR Backplane Alarm 25 Pin Dsub (P23)Alarm Signal1 EXT_GPI_1_2EXT_GPO_1_3GND4EXT_GPI_2_5 EXT_GPO_2_678910 GND1112
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-12913141516 GND17 BAT_STAT_18 MTR_STAT_19 EXT_VFWD20 EXT_VREV21 GND22 GND232425 GNDTable 8-61 QUAD BR Backplane RS-232 9 Pin Dsub (P22) RS-232 Signal1CD2RxD3TxD4DTR5GND6DSR7RTS8CTS9BRG*Table 8-60 QUAD BR Backplane Alarm 25 Pin Dsub (P23)Alarm Signal
Troubleshooting Volume 2QUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)8-130 6880801E35-E 22-Mar-06PS ConnectionsTable 8-62 QUAD PS Power and Signal (P11)Pin Description Pin Description Pin Description1 GND (Plug In) 31 3.3 Vdc 61 SPI_MOSI2GND 32 GND 62 SPI_CLK3 GND 33 GND 63 N.C.428.6 Vdc 34 GND 64 N.C.5 28.6 Vdc 35 GND 65 N.C.628.6 Vdc 36 GND 66 N.C.7 28.6 Vdc 37 GND 67 SPI_A0828.6 Vdc 38 GND 68 SPI_A19 28.6 Vdc 39 GND 69 SPI_M210 28.6 Vdc 40 GND 70 SPI_M311 28.6 Vdc 41 GND 71 SPI_M112 28.6 Vdc 42 GND 72 SLEEP_13 28.6 Vdc 43 GND 73 SPI_M014 28.6 Vdc 44 GND 74 WP_15 28.6 Vdc 45 GND 75 SPI_A216 14.2 Vdc 46 GND 76 GND17 14.2 Vdc 47 GND 77 GND18 14.2 Vdc 48 GND 78 GND19 14.2 Vdc 49 GND20 14.2 Vdc 50 GND21 14.2 Vdc 51 GND214.2 Vdc 52 GND23 14.2 Vdc 53 GND24 3.3 Vdc 54 NC (FAN CONTROL)25 3.3 Vdc 55 N.C.26 3.3 Vdc 56 N.C.
Volume 2 TroubleshootingQUAD Channel BR BackplaneEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-13127 3.3 Vdc 57 SHUTDOWN_28 3.3 Vdc 58 NC (Power sharing)29 3.3 Vdc 59 SPI_ENABLE30 3.3 Vdc 60 SPI_MISOTable 8-62 QUAD PS Power and Signal (P11)Pin Description Pin Description Pin DescriptionTable 8-63 QUAD BR 48 Vdc Battery Power (P12)Pin Description Description Pin1 + BATTERY + BATTERY 52+ BATTERY + BATTERY 63 - BATTERY (RTN) - BATTERY (RTN) 74- BATTERY (RTN) - BATTERY (RTN) 8
Troubleshooting Volume 2QUAD Base Radio SignalsEnhanced Base Transceiver System (EBTS)8-132 6880801E35-E 22-Mar-06QUAD Base Radio SignalsTable 8-64 lists and describes signals for the QUAD Base Radio.Table 8-64 QUAD Base Radio Signal DescriptionsSignal Name Description Special28.6 Vdc 28.6 Vdc output from PS14.2 Vdc 14.2 Vdc output from PS3.3 Vdc 3.3 Vdc output from PSGND Station GroundRX Branch 1 RX Branch 1 from RFDS 50 ¾RX Branch 2 RX Branch 2 from RFDS 50 ¾RX Branch 3 RX Branch 3 from RFDS 50 ¾RX1_EXP1 RX1 (branch 1) expansion output 1 50 ¾RX1_EXP2 RX1 (branch 1) expansion output 2 50 ¾RX1_EXP3 RX1 (branch 1) expansion output 3 50 ¾RX2_EXP1 RX2 (branch 2) expansion output 1 50 ¾RX2_EXP2 RX2 (branch 2) expansion output 2 50 ¾RX2_EXP3 RX2 (branch 2) expansion output 3 50 ¾RX3_EXP1 RX3 (branch 3) expansion output 1 50 ¾RX3_EXP2 RX3 (branch 3) expansion output 2 50 ¾RX3_EXP3 RX3 (branch 3) expansion output 3 50 ¾5 MHz/1 PPS 5 MHz/1 PPS reference to the BRCSPI_ENABLE Host Centric SPI EnableSPI_MISO Host Centric SPI MISOSPI_MOSI Host Centric SPI MOSISPI_CLK Host Centric SPI ClockSPI_A0 Host SPI Device Address Line A0SPI_A1 Host SPI Device Address Line A1SPI_A2 Host SPI Device AddressLine A2SPI_M0 Host SPI Module Address Line M0SPI_M1 Host SPI Module Address Line M1
Volume 2 TroubleshootingQUAD Base Radio SignalsEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-133SPI_M2 Host SPI Module Address Line M2SPI_M3 Host SPI Module Address Line M3WP_ Write Protect (active low)PA_ENABLE Turns off PA bias with active lowSLEEP_ Sleep signal from PSSHUTDOWN_ PS reset line from BRCCD RS232 Carrier DetectRxD RS232 RX DataTxD RS232 TX DataDTR RS232 Data Terminal ReadyDSR RS232 Data Set ReadyRTS RS232 Request to SendCTS RS232 Clear to SendBRG Baud Rate GeneratorRxRESET_ Reset Signal to RX modules16.8MHz_RX 16.8 MHz reference to RX differential16.8MHz_RX_RTN 16.8 MHz reference to RX return differentialClock_SyncA_ Clock Sync signal to RX1 & RX2 For Abacus IIIClock_SyncB_ Clock Sync signal to RX3 & RX4 For Abacus IIISSI_Data_A RX Data from RX module 1 differentialSSI_Data_A_RTN RX Data from RX module 1return differentialSSI_Data_B RX Data from RX module 2 differentialSSI_Data_B_RTN RX Data from RX module 2 return differentialSSI_Data_C RX Data from RX module 3 differentialSSI_Data_C_RTN RX Data from RX module 3 return differentialSSI_Data_D RX Data from RX module 4 differentialSSI_Data_D_RTN RX Data from RX module 4 return differentialTable 8-64 QUAD Base Radio Signal Descriptions (continued)Signal Name Description Special
Troubleshooting Volume 2QUAD Base Radio SignalsEnhanced Base Transceiver System (EBTS)8-134 6880801E35-E 22-Mar-06SSI_CLK_A RX Clock from RX module 1 differentialSSI_CLK_A_RTN RX Clock from RX module 1 return differentialSSI_CLK_B RX Clock from RX module 2 differentialSSI_CLK_B_RTN RX Clock from RX module 2 return differentialSSI_CLK_C RX Clock from RX module 3 differentialSSI_CLK_C_RTN RX Clock from RX module 3 return differentialSSI_CLK_D RX Clock from RX module 4 differentialSSI_CLK_D_RTN RX Clock from RX module 4 return differentialSSI_FS_A RX Frame Sync from RX module 1SSI_FS_B RX Frame Sync from RX module 2SSI_FS_C RX Frame Sync from RX module 3SSI_FS_D RX Frame Sync from RX module 4DSPIa_En_1 DSPa SPI RX1 Abacus enableDSPIa_En_3 DSPa SPI RX2 Abacus enableDSPIa_En_2 DSPa SPI RX1 & RX2 SGC enableDSPIb_En_1 DSPb SPI RX3 Abacus enableDSPIb_En_3 DSPb SPI RX4 Abacus enableDSPIb_En_2 DSPb SPI RX3 & RX4 SGC enableDSPIa_MOSI DSPa SPI MOSI differentialDSPIa_MOSI_RTN DSPa SPI MOSI return differentialDSPIb_MOSI DSPb SPI MOSI differentialDSPIb_MOSI_RTN DSPb SPI MOSI return differentialDSPIa_CLK DSPa SPI Clock differentialDSPIa_CLK_RTN DSPa SPI CLK return differentialDSPIb_CLK DSPb SPI Clock differentialDSPIb_CLK_RTN DSPb SPI CLK return differentialMTR_STAT_ External Wattmeter StatusBAT_STAT_ Battery StatusEXT_VFWD External Wattmeter Forward meterTable 8-64 QUAD Base Radio Signal Descriptions (continued)Signal Name Description Special
Volume 2 TroubleshootingQUAD Base Radio SignalsEnhanced Base Transceiver System (EBTS)22-Mar-06 6880801E35-E 8-135EXT_VREV External Wattmeter Reflected meterEXT_GPO_1_ General purpose output 1EXT_GPO_2_ General purpose output 2EXT_GPI_1_ General purpose input 1EXT_GPI_2_ General purpose input 2NC Not connected reservedTable 8-64 QUAD Base Radio Signal Descriptions (continued)Signal Name Description Special
Enhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-1Appendix AParts and SuppliersIn This Chapter Topic See PageOverview ...................................................................................... A-2Surge Arrestors  ............................................................................ A-3RF Attenuators  ............................................................................. A-5Emergency Generator .................................................................. A-7Portable Generator Connection  ................................................... A-8Site Alarms  ................................................................................... A-9Cabinet Mounting Hardware ....................................................... A-11Cable Connections  ..................................................................... A-12Battery System Connections ...................................................... A-13Intercabinet Cabling  ................................................................... A-16Equipment Cabinet Power Connections ..................................... A-18Other Recommended Suppliers  ................................................. A-20Spare Parts Ordering  ................................................................. A-22
Parts and Suppliers Volume 2OverviewEnhanced Base Transceiver System (EBTS)A-2 68P80801E35-E 16-June-06Overview 8This appendix contains recommended part numbers (p/n) and manufacturers for various hardware, tools, and equipment used during installation of the EBTS. Also contained in this appendix is other installation related information, such as determining types of wire lugs, lengths and sizes of various wires and cables, custom cabling information, and fuses. All suppliers and model numbers listed are included due to their performance record in previous installations. Motorola cannot guarantee the effectiveness of the installation or performance of the system when using these or other suppliers’ parts. Addresses, phone numbers, fax numbers, websites, and other information is presented for each of the recommended suppliers, when possible.Note In some listings, phone number and address are for corporate or main sales office. Other sales locations may be available. Call number given or go to website for expanded listings.Information herein is subject to change without notice.
Volume 2 Parts and SuppliersSurge ArrestorsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-3Surge Arrestors 8Two types of surge arrestors should be used in the EBTS site, including:■AC Power and Telco■Antenna Surge Arrestors AC Power and Telco Surge ArrestorsThe recommended AC Power and Telco surge arrestors are both manufactured by Northern Technologies. The model numbers are:■AC power - LAP-B for 120/240 single-phaseLAP-C for 208 Vac three-phase■Telco -  TCS T1DSNorthern Technologies23123 E. MissionLiberty Lake, WA 99019Phone: 800-727-9119Fax: 509-927-0435Internet: http://www.northern-tech.com
Parts and Suppliers Volume 2Surge ArrestorsEnhanced Base Transceiver System (EBTS)A-4 68P80801E35-E 16-June-06Antenna Surge ArrestorsThe recommended antenna surge arrestors are manufactured by Polyphaser Inc. The following models are recommended:■Base Radio antenna (800 MHz tower top amplifier only) - 094-0801T-A■Base Radio antenna (800 MHz cavity combined, transmit only; up to 5 channels) - IS-CT50HN-MA■Base Radio antennas (800 MHz duplexed) - IS-CT50HN-MA■Base Radio antennas (900 MHz duplexed) - 097-0311G-A.2■GPS antennas - 092-082-0T-A■Lightning arrestor bracket kit - Contact your local Motorola Sales representative to order this kit■Receive Tower Top amplifier - 094-0801T-A■Tower top test port cable - IS-50NX-C2Polyphaser, Inc.P.O. Box 9000Minden, NV 89423-9000 Phone: 800-325-7170775-782-2511Fax:  775-782-4476Internet: http://www.polyphaser.comMotorola has set up several kits that contain the necessary arrestors with proper mounting hardware for the various antenna configurations. Contact your local Motorola representative for these OEM kits.
Volume 2 Parts and SuppliersRF AttenuatorsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-5RF Attenuators 8Several RF attenuators are needed at a site to ensure proper receive adjust-ments. The attenuators are used at the LNA sites to offset the excess gain from the Tower Top amplifiers, to balance the receive path, and to attenuate the BMR signal path. Use the following specifications when choosing vendors:■Specified frequency range▲800 MHz systems – requires attenuator specification to include 806-821 MHz range▲900 MHz systems – requires attenuator specification to include 896-902 MHz range■1 dB increments■0.5 dB accuracy or better■Female N connector / Male N connectorAeroflex / Weinschel5305 Spectrum DriveFrederick, MD 21703-7362745Phone: 800-638-2048301-846-9222Fax: 301-846-9116Internet: http://www.aeroflex-weinschel.comAlan Industries, Inc.745 Green Way DriveP.O. Box 1203Columbus, IN 47202Phone: 800-423-5190812-372-8869Fax: 812-372-5909Internet: http://www.alanindustries.comHuber + Suhner, Inc.19 Thompson DriveEssex, VT 05452Phone: 802-878-0555Fax: 802-878-9880Internet: http://www.hubersuhnerinc.com
Parts and Suppliers Volume 2RF AttenuatorsEnhanced Base Transceiver System (EBTS)A-6 68P80801E35-E 16-June-06JFW Industries, Inc.5134 Commerce Square DriveIndianapolis, IN 46237Phone: 877-887-4JFW317-887-1340Fax: 317-881-6790Internet: http://www.jfwindustries.comPasternack EnterprisesP.O. Box 16759Irvine, CA 92623-6759Phone: 949-261-1920Fax: 949-261-7451Internet: http://www.pasternack.comRF attenuators are also needed for test equipment. The attenuators must be used between frequency reference equipment, service monitors, and the Motorola EBTS equipment. The following attenuators should be used at the site during optimization:■Female BNC connector / Male BNC connector, 10 dB attenuator (1 W) between the Rubidium Standard and the R2660 Communications Analyzer. Refer to the System Testing section.■Female BNC connector / Male BNC connector, 30 dB attenuator (1 W) between the Rubidium Standard and the R2660. Refer to the System Testing, section.
Volume 2 Parts and SuppliersEmergency GeneratorEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-7Emergency Generator 8Several different sizes of generators are available. Determine the loading requirements of the site prior to ordering a generator. A recommended manufacturer of the emergency backup generator power system is:Generac CorporationP.O. Box 8Waukesha, WI 53187Phone: 262-544-4811Fax: 262-544-0770
Parts and Suppliers Volume 2Portable Generator ConnectionEnhanced Base Transceiver System (EBTS)A-8 68P80801E35-E 16-June-06Portable Generator Connection 8The recommended portable generator connection is the AJA200-34200RS, manufactured by Appleton Electric. Figure A-1 is a view of a connector located on the building. An adapter may be required if local electrical standards conflict with the wiring configuration.Figure A-1 Portable Generator Connector An alternate supplier of the portable generator connection is the ARKTITE Heavy Duty Receptacle Model 80, Style 2, 200 Amps, manufactured by Crouse-Hinds.Cooper IndustriesCrouse-Hinds, Inc.P.O. Box 4999Syracuse, NY 13221Phone: 315-477-5531Fax: 315-477-5719Internet: http://www.crouse-hinds.comEBTS078061295JNM123HOTHOT NEUTRALGROUNDPOLARIZATIONRIB
Volume 2 Parts and SuppliersSite AlarmsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-9Site Alarms 8■Three types of alarms should be used in an EBTS site, including: ■Intrusion Alarm■Smoke Alarm■Temperature AlarmIntrusion Alarm The intrusion alarm is the Sonitrol Door contact 29A.Sonitrol 211 N. Union Street, Suite 350Alexandria, VA 22314Phone: 800-326-7475703-684-6606Fax: 703-684-6612Internet: http://www.sonitrol.comSmoke Alarm An available smoke alarm is the Sentrol 320CC. This smoke alarm provides a relay closure for the iMU alarm. These smoke detectors are available from many electrical wholesale distributors. For the location nearest you, call between 6 a.m. and 5 p.m. Pacific Standard Time and ask Sales for the location of the nearest EW (Electric Wholesale) distributor.Sentrol, Inc.GE Interlogix12345 SW Leveton DriveTualatin, OR 97062Phone: 800-547-2556503-692-4052Internet: http://www.sentrol.com
Parts and Suppliers Volume 2Site AlarmsEnhanced Base Transceiver System (EBTS)A-10 68P80801E35-E 16-June-06Temperature Alarm The recommended temperature alarm is the Grainger #2E206 thermostat. This alarm is manufactured by Dayton Electronics and distributed by W.W. Grainger:W.W. GraingerLocations NationwidePhone: 888-361-8649 Internet: http://www.grainger.com
Volume 2 Parts and SuppliersCabinet Mounting HardwareEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-11Cabinet Mounting Hardware 8The cabinet mounting hardware is site dependent and must be procured locally. Equipment Cabinets The mounting hardware used to secure the Equipment Cabinets containing control and/or RF hardware must be able to provide 1545 pounds of retention force. ■If the cabinets are to be secured to a concrete floor, 1/2” grade 8 bolts with anchors are recommended. ■If the cabinets are to be secured to another type of floor, determine the appropriate mounting hardware.Power Supply Rack The Motorola offered Power Supply rack from Power Conversion Products is available in a standard and an earthquake rack.Power Conversion Products, Inc.115 Erick StreetCrystal Lake, IL 60039-0380Phone: 800-435-4872 (customer service)815-479-0682Fax: 815-459-0453Internet: http://www.eltekenergy.comIf the earthquake rack is used, it must be bolted to the floor using the 02100-13 High Performance Anchor Kit, consisting of:■anchors (qty. 4)■load sharing plates (qty. 2)■large square washers (qty. 8)Hendry Telephone Products55 Castilian DriveSanta Barbara, CA 93117-3080Phone: 805-968-5511Fax: 805-968-9561Internet: http://www.hendry.com
Parts and Suppliers Volume 2Cable ConnectionsEnhanced Base Transceiver System (EBTS)A-12 68P80801E35-E 16-June-06Cable Connections 8The recommended manufacturer for all wire lugs used during EBTS instal-lation is Thomas & Betts. All wire lug part numbers listed are for Thomas & Betts.Thomas & Betts8155 T&B BoulevardMemphis, TN 38125Phone: 800-888-0211 (general information)800-248-7774 (sales/technical support)Internet: http://www.tnb.comNote Double hole wire lugs are preferred, but single hole wire lugs can be used where mounting requirements dictate their use.Selecting Master Ground Bar LugsTable A-1 identifies recommended part numbers for wire lugs used to connect chassis ground wiring to the master ground bar from each cabinet. Selecting Cabinet Ground LugsTable A-2 identifies recommended part numbers for wire lugs used to connect chassis ground wiring to the grounding point of each cabinet. Table A-1 Recommended Master Ground Bar LugsWire Size Wire Type Lug Color Description P/N †#2 AWG Stranded Brown Single 1/4” diameter hole 54107#2 AWG Stranded Brown Double 1/4” diameter hole, 5/8” center 54207#6 AWG Stranded Blue Single 1/4” diameter hole 54105#6 AWG Stranded Blue Double 1/4” diameter hole, 5/8” center 54205Note These lugs require the use of the TBM5-S crimping tool. Note † All part numbers are Thomas & Betts.Table A-2 Recommended Junction Panel Ground LugsWire Size Wire Type Lug Color Description P/N †#2 AWG Stranded Brown Single 1/2” diameter hole 54145#6 AWG Stranded Blue Single 3/8” diameter hole E6-12 Note These lugs require the use of the TBM5-S crimping tool.Note † All part numbers are Thomas & Betts.
Volume 2 Parts and SuppliersBattery System ConnectionsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-13Battery System Connections 8The cable loop length refers to the total length of wire within a given circuit. For example, the combined length of the -48 VDC (hot) lead and the DC return lead equals the cable loop length. This would mean that a cabinet that needs 16 feet of wire between the batteries and Power Supply Rack has a total loop length of 32 feet.Determining Battery System Wire SizeThe wire size for the connection between the batteries and the Power Supply Rack is determined by the required wire length and the maximum allowable voltage drop. The voltage drop in the loop must be kept to below 200 mV. The wire selected should be UL approved and contain a high number of strands for flexibility.For a standard configuration, the Power Supply rack is located directly adjacent to the batteries with a cable loop length of 20 feet or less, which requires the use of a 4/0 wire. Table A-3 shows recommended wire sizes for various loop lengths. Larger wire sizes may be used if the recommended sizes are not available. The recommended wire sizes are large enough to allow site expansion to a fully loaded site.Selecting Battery System LugsDepending on the wire size used and the manufacturer of the Batteries, different wire lugs are crimped onto the power cable ends. After the wire size has been determined from Table A-3, verify the manufacturer of the Batteries (Dynasty or Absolyte). Two different battery systems are offered with the EBTS. The Dynasty system is a low to medium capacity, field expandable system supplied for smaller sites or sites with minimal backup hour requirements. This system is custom designed to Motorola specifications. The Dynasty system is manufactured by Johnson Controls:Table A-3 Battery System Wire SizeLoop Length Wire size20 feet 4/0 (or 250 MCM)30 feet 350 MCM45 feet 500 MCM
Parts and Suppliers Volume 2Battery System ConnectionsEnhanced Base Transceiver System (EBTS)A-14 68P80801E35-E 16-June-06C & D TechnologiesDynasty Division900 East Keefe AvenueP.O. Box 591Milwaukee, WI 53212Phone: 800-396-2789414-967-6500Fax: 414-961-6506Internet: www.dynastybattery.comThe Absolute IIP battery system is a heavy duty, high capacity battery system manufactured by GNB Technologies:GNB Technologies829 Parkview BoulevardLombard, IL 60148Phone: 630-629-5200Fax: 630-629-2635Internet: www.gnb.com/stationary/stat-absp.htmlRefer to Table A-4 to determine the proper wire lug for the connection of that wire to the Power Supply rack.Table A-4 Power Supply Rack Connection LugsWire Size Cabinet Lug Crimp Tool Lug P/N †4/0  Double 3/8” hole, 1” center TBM5-S 54212250 MCM Double 3/8” hole, 1” center TBM8-S 54213350 MCM Double 3/8” hole, 1” center TBM8-S 54215500 MCM Double 3/8” hole, 1” center TBM8-S 54218Note † All part numbers are Thomas & Betts.
Volume 2 Parts and SuppliersBattery System ConnectionsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-15Refer to Table A-5 to determine the proper wire lug for the connection to the batteries, based on the wire size and battery manufacturer. One column lists the selection for Dynasty and the other lists the selection for Absolyte IIP.Anti-Oxidant GreasesAny one of the following anti-oxidant greases are recommended for connec-tions to the positive (+) and negative (-) terminals of the batteries:■No-Ox■OxGuard■PenetroxTable A-5 Battery Connection LugsWire SizeLug ColorDynasty Absolyte IIPDescription P/N Description P/N4/0  Purple Double 3/8” hole, 1” center 54212 Single 1/2” hole 54170250 MCM Yellow Double 3/8” hole, 1” center 54215 Single 1/2” hole 54113350 MCM Red Double 3/8” hole, 1” center 54218 Single 1/2” hole 54115500 MCM Brown Double 3/8” hole, 1” center 54220 Single 5/8” hole 54118
Parts and Suppliers Volume 2Intercabinet CablingEnhanced Base Transceiver System (EBTS)A-16 68P80801E35-E 16-June-06Intercabinet Cabling 8Ethernet and alarm cables connecting to the junction panels of each cabinet are supplied with the system. These cables may not be suitable for every EBTS site. It may be necessary to locally manufacture cables for a custom fit. Information is provided for both supplied cables and custom cables.Supplied Cables The cables listed in Table A-6 are supplied with the system. The length of these cables should be sufficient if the considerations outlined in the Pre-Installation section are followed.Making Custom CablesIf custom Ethernet or 5 MHz cables must be locally manufactured, use the part numbers listed in Table A-7 for ordering the required materials.Table A-6 Supplied Inter-Cabinet CablingDescription Qty. P/N †120" long, N-type Male to N-type male cable 3 0112004B24108" long, BNC Male-to-BNC Male, RG400 cable 2* 3013943N45210" long, 8-pin Modular plug cable 1* 3084225N42186" long, PCCH redundancy control cable 1** 3082070X01Phasing Harness 1 0182004W04Note †  All part numbers are Motorola.Note * Per RF rack.Note ** Per Control rack.Table A-7 Parts for Ethernet and 5 MHz CablesDescription Qty. P/N †Connector, BNC male  As required 2884967D01Cable, RG400         As required 3084173E01
Volume 2 Parts and SuppliersIntercabinet CablingEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-17Table A-8 lists the part numbers for custom alarm cables.Table A-9 lists the part numbers for custom PCCH cables.Table A-8 Parts for Alarm CablesDescription Qty. P/N †Connector, 8-pin modular As required 2882349V01Cable, 8-wire As required Locally procuredNote † All part numbers are Motorola.Table A-9 Parts for Extending PCCH Redundancy Control CablesDescription Qty. P/N †8-pin male Telco to 8-pin male Telco extension cable, length: as neededAs required Locally procuredNote Motorola does not guarantee proper operation of system if longer PCCH cable is used.Note † All part numbers are Motorola.Note * Per Control rack.
Parts and Suppliers Volume 2Equipment Cabinet Power ConnectionsEnhanced Base Transceiver System (EBTS)A-18 68P80801E35-E 16-June-06Equipment Cabinet Power Connections 8Selecting Power Connection LugsTable A-10 identifies recommended part numbers for lugs used for power connections between the Power Supply rack and the Control and RF Cabinets. The maximum wire size accepted by the Control and RF Cabinets is 2/0. The Control and RF Cabinets use screw type compression connectors and do not require lugs.Determining Power Connection Wire SizeThe cable loop length refers to the total length of wire within a given circuit. For example, the combined length of the -48 VDC (hot) lead and the DC return lead equals the cable loop length. This would mean that a cabinet which needs 16 feet of wire between the Power Supply rack and equipment cabinets has a total loop length of 32 feet.The wire size for the connection between the Power Supply rack and the equipment cabinets is determined by the required wire length and the maximum allowable voltage drop. The voltage drop in the loop must be kept to below 500 mV. The wire selected should be UL approved and contain a high number of strands for flexibility. Table A-11 shows the recommended wire sizes for various loop lengths of the RF Cabinet. Table A-12 shows the recommended wire sizes for loop lengths of the Control CabinetFor a standard configuration, the equipment cabinets are located adjacent to the Power Supply rack with a cable loop length less than 35’.Table A-10 Recommended Power Connection Lugs for Power Supply RackSize Lug Color Description P/N †2/0 Black Double 3/8” hole, 1” center 54210#2 AWG Brown Double 1/4” hole, 5/8” center 54207#4 AWG Gray Double 1/4” hole, 5/8” center 54206#6 AWG Blue Double 1/4” hole, 5/8” center 54205Note † All part numbers are Thomas & Betts.Table A-11 Power Connection Wire SizeLoop Length Wire Size25 feet or less #6 AWG25 to 40 feet #4 AWG
Volume 2 Parts and SuppliersEquipment Cabinet Power ConnectionsEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-19Each equipment cabinet has a total of four Power Supply Rack connections; two -48 VDC (hot) and two DC return. Each equipment cabinet contains two separate power distribution systems. A single hot wire and a single return wire are used for each side of the bus. Two return leads provide redundancy and allow a uniform wire size to be used for all 48 VDC power distribution system connections.40 to 60 feet #2 AWG60 to 130 feet 1/0 AWGNote The wire sizes listed are large enough to allow full RF Cabinet Base Radio capacity.Table A-12 Power Connection Wire Size for Control CabinetLoop Length Wire Size150 feet or less #6 AWGTable A-11 Power Connection Wire Size (continued)Loop Length Wire Size
Parts and Suppliers Volume 2Other Recommended SuppliersEnhanced Base Transceiver System (EBTS)A-20 68P80801E35-E 16-June-06Other Recommended Suppliers 8The following are the addresses of various suppliers for tools and equipment used during installation of the EBTS.Test Equipment ■RubiSourceSymmetricom2300 Orchard ParkwaySan Jose, California 95131Phone: 408-433-0910Fax: 408-428-7896Internet: http://www.symmetricom.com■Fluke 77 Digital MultimeterFluke CorporationP.O. Box 9090Everett, WA 98206-9090Phone: 800-44-FLUKE425-347-6100Fax: 425-356-5116Internet: http://www.fluke.comDrive Test EquipmentA PC can be used for EBTS optimization and field service. The following are the minimum requirements:■19,200 bps serial port■one floppy drive■communication software, such as Smartcomm II or Procomm PlusA drive test application is only available for the PC platform and is currently called iFTA (iDEN Field Test Application). Contact your local Motorola sales representative for more information.
Volume 2 Parts and SuppliersOther Recommended SuppliersEnhanced Base Transceiver System (EBTS)16-June-06 68P80801E35-E A-21Software ■ProComm Plus softwareSymantec Corporation20330 Stevens Creek Blvd.Cupertino, CA 95014Phone:  408-517-8000Internet:  http://www.symantec.com
Parts and Suppliers Volume 2Spare Parts OrderingEnhanced Base Transceiver System (EBTS)A-22 68P80801E35-E 16-June-06Spare Parts Ordering 8Motorola Inc.Accessories and Aftermarket DivisionAttn:  Order Processing1307 E. Algonquin RoadSchaumburg, IL 60196Returns:2222 Glavin DriveElgin, IL 60123Phone:   800-422-4210 (sales/technical support)Fax:  847-538-8198Newark ElectronicsCall for a local phone number in your area to order partsPhone: 800-463-9275 (catalog sales)773-784-5100Fax:  847-310-0275Internet:  http://www.newark.com

Navigation menu