Mileseey Technology MC160002 Laser Distance Meter User Manual 2AEOGMC160002

Shenzhen Mileseey Technology Co., Ltd Laser Distance Meter 2AEOGMC160002

2AEOGMC160002_User Manual

Laser Distance MeterUser ManualThis device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.”FCC ID2AEOGMC160002Radio Frequency Interference Requirements-FCCNote: This equipment has been tested and found to comply with the limits for aClass B digital device, pursuant to Part 15 of the FCC rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:• Reorient or relocate the receiving antenna• Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected• Consult the dealer or an experienced radio/TV technician for help.MODIFICATION: Any changes or modifications not expressly approved by the grantee of thisdevice could void the user’s authority to operate the device.Radio Transmitters (Part 15)This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.EnglishCongratulations on the purchase of your products.Carefully read the Safety Instructions and the User Manual before using thisproduct.The person responsible for the instrument must ensure that all users understand thesedirections and adhere to them.
ContentsSafety Instructions ..................................................................................................... 1Appearance diagram ......................................................................................................6Warning  ....................................................................................................................6Specification................................................................................................................6Operation on touch panel ............................................................................................. 7Operating procedures ................................................................................................... 8Error code.......................................................................................................................9Bluetooth wireless data transfer.................................................................................. 10Battery installation.......................................................................................................10Contact us.....................................................................................................................11Copyrights....................................................................................................................11
1Safety InstructionsSymbols usedThe following displays are used to distinguish precautions by the degreeof injury or damagethat may result in the precaution is ignored.WARNING:Indicate a potentially hazardous situation or an unintended use which, if not       avoided, will result in death or serious injury.CAUTION:Indicate a potentially hazardous situation or an unintended use which, if not       avoided, may result in minor injury and / or in appreciable material, financial       and environmental damage.Important paragraphs which must be adhered to in practice as they enable         the product to be used in a technically correct and efficient manner.Use of the instrumenta). Slide down the button to switch on the device. The laser beam emits from the front.b). Press    to measure the distance. The result will show on the screen.If there is no laser beam or no data displayed on the screen, ntact the local dealer for advice orsolution.Possible danger when use the device:-The laser beam will harm eyes when aim to eyes directly-The device may produces a spark and light dust or gas-When clean battery electrolyte, heman fingers may be affected-The device may cause an hazardous radiation explosion-Laser exposure radiation damageCaution:-Do not look straight at the laser beam-Do not use the device in inflammable and explosive environment-Remove the batteries to avoid the electrolyte leakage when not use the device.-Do not try other functions that the device does not have itself-Do not attempt to convert the performance of the device in any way- After repaired, this equipment shall be re-evaluated to comply with the safety requirementaccording to standard EN 61010-1: 2010.- If the equipment is used in a manner not specified by the manufacture, the protectionprovided by the equipment may be impaired.- This equipment contains no operator serviceable parts, serviced by the qualified person
2only.- Must be consulted this manual in all cases where symbol    is marked.CareWipe off dirt with a damp, soft cloth. If the water does not clean the dirt, use a clean clothmoistened with alcohol to wipe the dirt. Be careful with the optical components (such as opticallens): wipe with a clean soft cloth or cotton swab moistened with distilled water (as cleaningglass or camera lens).Do not use aggressive cleaning agents or solutions.Permitted useMeasuring distancesComputing functions, e.g. area and indirect measurement.Prohibited useUsing the instrument without instruction.Using outside the stated limits.Deactivation of safety systems and removal of explanatory and hazard labels.Opening of the equipment by using tools (screw drivers, etc.), as far as notspecifically permitted for certain cases.Carrying out modification or conversion of the product.Use of accessories from other manufacturers without the express approval of ourcompany.Deliberately or irresponsible behavior on scaffolding, when using ladders, whenmeasuring near machines which are running, or near parts of machines orinstallations which are unprotected.Aiming directly into the sun.Deliberately dazzling of third parties; also in the dark.Inadequate safeguards at the surveying site (e.g. when measuring on roads,construction sites, etc.)Limits of useSee section “Technical Date” .The product is designed for use in areas permanently habitable by humans, do not usethe product in explosion hazardous areas or in aggressive environments.Areas of responsibility
3As the original producer responsiblity:Responsible for providing security products include manual and origin of the parts.Responsibilities of the manufacturer of non-original accessories:The manufacturers of non-original accessories for the products are responsible fordeveloping, implementing and communicating safety concepts for their products.They are also responsible for the effectiveness of these safety concepts in combinationwith the products equipment.Responsibilities of the person in charge of the instrument:WARNING:The person responsible for the instrument must ensure that the equipment isused in person is also accountable for the deployment of personnel and for theiraccordance with the instructions. This training and for the safety of the equipmentwhen in use. The person in charge of the instrument has the following duties:To understand the safety instructions on the product and the instructions in theUser Manual.To be familiar with local safety regulations relating to accident prevention.To inform local dealser immediately if the equipment becomes unsafe.Hazards in useCAUTION:Watch out for erroneous distance measurements if the instrument is defective or if ithas been dropped or has been misused or modified.Precautions:Carry out periodic test measurements. Particularly after the instrument has beensubject to abnormal use, and before, during and after important measurements.Make sure the optics is kept clean and that there is no mechanical damage to thebumpers.CAUTION:In using the instrument for distance measurements or for positioning moving objects(e.g. cranes, building equipment, platforms, etc.)Unforseen events may cause erroneous measurements.Precautions:Only use this product as a measuring sensor, not as a control device. Your system
4must be configured and operated in such a way, that in case of an erroneousmeasurement, malfunction of the device or power failure due to installed safetymeasures (e.g. safety limit switch), it is assured that no damage will occur.WARNING:Flat batteries must not be disposed of with household waste. Care for the environment.Always prevent access to the product by unauthorized personnel.And take them to the collection points provided in accordance with nationalor local regulations. The product must not be disposed of with household waste.Dispose of the product appropriately in accordance with the national regulations inforce in your country.Electromagnetic Compatibility (EMC)The term “electromagnetic compatibility” is taken to mean the capability of theproduct to function smoothly in an environment where electromagnetic radiation andelectrostatic discharges are present, and without causing electromagnetic interferenceto other equipment.WARNING:The products conform to the most stringent requirements of the relevant standards andregulations. Yet, the possibility of it causing interference in other devices cannot betotally excluded.CAUTION:Never attempt to repair the product yourself. In case of damage, contact the localdealership.
5Laser classificationIntegrated distance meter- That produces a visible laser beam which emerges from the front of the instrument.It is a Class 2 laser product in accordance with:IEC60825-1: 2007 “Radiation safety of laser products”- Do not stare into the laser beam or direct it towards other people unnecessarily.- Eye protection is normally afforded by aversion responses including the blink reflex.- The radiation pattern emitted from this equipment during the performance ofoperation and maintenance procedure:Wavelength: 630-670nmBeam divergence: 0.16 x 0.6 mradPulse duration: 0.25s (continuous)Maximum power or energy output: <1mW- Caution – Use of controls or adjustments or performance of procedures other thanthose specified herein may result in hazardous radiation exposure.WARNING:Looking directly into the beam with optical aids ( e.g. binoculars, telescopes) can behazardous.Precautions:Do not look directly into the beam with optical aids.CAUTION:Looking into the laser beam may be hazardous to the eyes.Precautions:Do not look into the laser beam. Make sure the laser is aimed above or below eyelevel. (particularly with fixed installations, in machines, etc.)
6Appearance diagramWarningLaser Class 2 products;Do not look directly intothe bean with optical aids or direct it towards otherpeople unnecessarily.SpecificationSpecification dTape 5TMeasuring range0.2~60mMeasuring accuracy+/-2mmContinuous measurement Area measurement Pythagorean measurement Auto level Auto height DisplayMeasuringbuttonSlide downto power onSlide up topower offTripod screw holesBatterycompartment
7Touch screen Tilt measurement Bluetooth Bluetooth 4.0Reference Front/middle/rearMeasuring unit m/ft/in/ft+inLaser class Class 2Laser type 630-670nm,1mWBattery type AAA 2X1.5VRemark:  The maximum measuring range is determined by the version of laser distancemeter. Exact measuring range is shown on the gift box.  In unfavorable conditions, such as intense sunshine, poorly reflecting targetsurface (black surface) or high temperature variations, the deviation over 10m ofdistance may increase.*During daylight or if the target has poor reflection properties, please use target plate.Operation on touch panelSlide left or rightSlide left or right to exchange functionsbetween: Continuous measurement,Pythagoras indirect measurement, Areameasurement, Volume measurementAuto level,Auto height.Slide up or downSlide down to enter into setting menu, andclick on icons to change relevant setting.Slide up to exit setting menu.
8Operating proceduresSlide on the screen left or right to exchange measuring mode.The red side on the icon is to be measured.Continuous measurementThe device goes to continuous measurementdirectly when it’s powered on, click on thescreen or press the measuring button to holdthe measurement, press the measuring buttonto measure again.*This function will be stopped automaticallyafter 5 minutes of inactivity.Pythagorean Method-Two pointsSlide on the screen left or right to locate thePythagorean Method-Two points icon         ,press      to take the first distance measure-ment .press       to take the second distance(keepthe instrument horizontal).The results of first length, second length andthe height will be orderly displayed on thescreen.Area measurementSlide on the screen to locate the areameasurement icon      , and press     buttonto take the first distance measurement(e.g. Length).Press       again to take the second distancemeasurement (e.g. width).The results of length, width, and area will bedisplayed in the display orderly.Auto levelSlide on the screen to locate auto level icon     ,and press measuring button      to measure thelength of Hypotenuse, then Hypotenuse, Verticaland horizontal distance will be displayed on thescreen.
9Auto heightSlide on the screen to locate auto height icon      ,and press measuring button      to measure thefirst distance. Press     again, take the seconddistance.The results of first length, second length andthe height will be orderly displayed on thescreen.Error codeAll errors or failures will be shown as codes. The following table explains themeaning ofcodes and solutions.Code Cause Corrective Measure204 Calculation error Refer to user manual,repeat theprocedures.208 Excessive current Please contact yourdistributer220 Battery low Replace new batteries252 Temperaturetoo high Let device cool down tooperatingtemperatureat 0°C-40°C.253 Temperaturetoo low Warm up the device tooperatingtemperature.255 Received signaltoo weakormeasurementtime too longUse target plate orchange agoodreflective surface256 Received signaltoo strong Target too reflective,use target plate ordonot aim at strong lightobjective.261 Outside of therangeofmeasurementSelect the measurementdistance withinthe rangeof measurement.500 Hardware error Switch on/off thedevice several times.Ifthe symbol stillappears, pleasecontactyour dealer forassistance.
10Bluetooth wireless data transferOperation on the deviceClick Bluetooth icon       on the setting menu, when the icon lights up, it meansBluetooth is activated, and it flashes waiting for connection.Operation on AppOpen APP to enter scene measuring, press the Bluetooth button     on up-right,then the Bluetooth will be turned on. Search for Bluetooth name of theinstrument:          ,   click and connect it. After connection, Bluetooth icon turnsgreen, and the Bluetooth icon  on the device stops flashing, users can remotelycontrol the device.*As D520T do not have the function of data recording, the Import Records function inthe APP can not be used.Bluetooth function can only work with the APP, Please download and installMileseey APP in advance. APP name: “Mileseey iMeter”. Android users candownload in the Android market or official website of Mileseey. Apple users candownload and install directly in App Store.APP Operating environment requirements:Android platform: Android 4.3 and above version. The Bluetooth module need to beversion 4.3 and above.iOS platform: applicable to the iPhone 4S and above, iPad 3 and above.APP name: “Mileseey iMeter”.APP Operating environment requirements:1, Android platform: Android 4.3 and above version. The Bluetoothmodule need to be version 4.3 and above, lowpower Bluetooth.2, iOS platform: Applicable to the iPhone 4s and above, iPad 3 and above.Battery installationOpen the battery cover, put two batteries into the compartment correctly according tothe sign of positive and negative pole. Close the cover after installation for safe use.
11Contact usMileSeey Technology Co., LTDTel: +86 755 86329055Fax: +86 755 86701592Website: www.mileseey.netEmail: info@mileseey.netAddress: F/6, Building 9, Zhongguan Honghualing Industrial South Park II, 1213 Liuxian Ave,Taoyuan Street, Nanshan District, Shenzhen, 518055, The Maximum P.R. China.CopyrightsProduct design, specifications may change without prior notice. MileSeey trademark, images,specifications are properties of MileSeey Technology Co., LTD. All rights reserved.