MaxStream355 South 520 West, Suite 180 Lindon, UT  84042 Phone: (801) 765-9885 Fax: (801) 765-9895rf-xperts@maxstream.net www.MaxStream.net (live chat support)XBee™/XBee-PRO™ OEM RF ModulesXBee/XBee-PRO OEM RF ModulesRF Module OperationRF Module ConfigurationAppendicesProduct Manual v1.xAx - 802.15.4 ProtocolFor OEM RF Module Part Numbers: XB24-...-001, XBP24-...-001IEEE® 802.15.4 OEM RF Modules by MaxStream M1002322007.05.031
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. ii© 2007 MaxStream, Inc. All rights reservedThecontentsofthismanualmaynotbetransmittedorreproducedinanyformorbyanymeanswithoutthewrittenpermissionofMaxStream,Inc.XBee™andXBee‐PRO™aretrademarksofMaxStream,Inc.TechnicalSupport:Phone:(801)765‐9885LiveChat:www.maxstream.netE‐mail:rf‐xperts@maxstream.net
ContentsXBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. iii1. XBee/XBee-PRO OEM RF Modules 41.1.  Key Features   41.1.1.  Worldwide Acceptance   41.2.  Specifications   51.3.  Mechanical Drawings   61.4.  Mounting Considerations   61.5.  Pin Signals   71.6.  Electrical Characteristics   82. RF Module Operation 92.1.  Serial Communications   92.1.1.  UART Data Flow   92.1.2.  Transparent Operation   102.1.3.  API Operation   102.1.4.  Flow Control   112.2.  ADC and Digital I/O Line Support   122.2.1.  I/O Data Format   122.2.2.  API Support   132.2.3.  Sleep Support   132.2.4.  DIO Pin Change Detect   132.2.5.  Sample Rate (Interval)   132.2.6.  I/O Line Passing   142.2.7.  Configuration Example   142.3.  XBee/XBee-PRO Networks   152.3.1.  NonBeacon   152.3.2.  NonBeacon (w/ Coordinator)   152.3.3.  Association   162.4.  XBee/XBee-PRO Addressing   192.4.1.  Unicast Mode   192.4.2.  Broadcast Mode   192.5.  Modes of Operation   202.5.1.  Idle Mode   202.5.2.  Transmit/Receive Modes   202.5.3.  Sleep Mode   222.5.4.  Command Mode   243. RF Module Configuration 253.1.  Programming the RF Module   253.1.1.  Programming Examples   253.2.  Command Reference Tables   263.3.  Command Descriptions   343.4.  API Operation   543.4.1.  API Frame Specifications   543.4.2.  API Types   55Appendix A: Agency Certifications 59United States (FCC)   59OEM Labeling Requirements   59FCC Notices   59FCC-Approved Antennas (2.4 GHz)   60Europe (ETSI)   61OEM Labeling Requirements   61Restrictions   61Declarations of Conformity   61Approved Antennas   62Canada (IC)   62Labeling Requirements   62Japan   62Labeling Requirements   62Appendix B: Development Guide 63Development Kit Contents   63Interfacing Options   63RS-232 Development Board   64External Interface   64RS-232 Pin Signals   65Wiring Diagrams   66Adapters   67USB Development Board   68External Interface   68USB Pin Signals   68X-CTU Software   69Installation   69Serial Communications Software   69Appendix C: Additional Information 701-Year Warranty   70Ordering Information   70Contact MaxStream   71
©2007MaxStream,Inc. 41.XBee/XBee‐PROOEMRFModulesThe XBee and XBee-PRO OEM RF Modules were engineered to meet IEEE 802.15.4 standards and support the unique needs of low-cost, low-power wireless sensor networks. The modules require minimal power and provide reliable delivery of  data between devices.The modules operate within the ISM 2.4 GHz frequency band and are pin-for-pin compatible with each other.1.1. Key FeaturesLong Range Data IntegrityXBee• Indoor/Urban: up to 100’ (30 m)• Outdoor line-of-sight: up to 300’ (100 m)• Transmit Power: 1 mW (0 dBm)• Receiver Sensitivity: -92 dBmXBee-PRO• Indoor/Urban: up to 300’ (100 m)• Outdoor line-of-sight: up to 1 mile (1500 m)• Transmit Power: 100 mW (20 dBm) EIRP• Receiver Sensitivity: -100 dBmRF Data Rate: 250,000 bpsAdvanced Networking & SecurityRetries and AcknowledgementsDSSS (Direct Sequence Spread Spectrum)Each direct sequence channels has over 65,000 unique network addresses availableSource/Destination AddressingUnicast & Broadcast CommunicationsPoint-to-point, point-to-multipoint  and peer-to-peer topologies supportedCoordinator/End Device operationsLow PowerXBee• TX Current: 45 mA (@3.3 V)• RX Current: 50 mA (@3.3 V)• Power-down Current: < 10 µAXBee-PRO• TX Current: 215 mA (@3.3 V)• RX Current: 55 mA (@3.3 V)• Power-down Current: < 10 µAADC and I/O line supportAnalog-to-digital conversion, Digital I/OI/O Line PassingEasy-to-UseNo configuration necessary for out-of box RF communicationsFree X-CTU Software (Testing and configuration software)AT and API Command Modes for  configuring module parametersExtensive command setSmall form factorFree & Unlimited RF-XPert Support1.1.1. Worldwide AcceptanceFCC Approval (USA) Refer to Appendix A [p59] for FCC Requirements. Systems that contain XBee/XBee-PRO RF Modules inherit MaxStream Certifications.ISM (Industrial, Scientific & Medical) 2.4 GHz frequency bandManufactured under ISO 9001:2000 registered standardsXBee/XBee-PRO RF Modules are optimized for use in the United States, Canada, Australia, Israel and Europe. Contact MaxStream for complete list of government agency approvals.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 5Chapter1‐XBee/XBee‐PROOEMRFModules1.2. Specifications*WhenoperatinginEurope:XBee‐PRORFModulesmustbeconfiguredtooperateatamaximumtransmitpoweroutputlevelof10dBm.ThepoweroutputlevelissetusingthePLcommand.ThePLparametermustequal“0”(10dBm).Additionally,EuropeanregulationsstipulateanEIRPpowermaximumof12.86dBm(19mW)fortheXBee‐PROand12.11dBmfortheXBeewhenintegratinghigh‐gainantennas.**WhenoperatinginJapan:Transmitpoweroutputislimitedto10dBm.AspecialpartnumberisrequiredwhenorderingmodulesapprovedforuseinJapan.ContactMaxStreamformoreinformation[call1‐801‐765‐9885orsende‐mailstosales@max‐stream.net].Antenna Options: The ranges specified are typical when using the integrated Whip (1.5 dBi) and Dipole (2.1 dBi) anten-nas. The Chip antenna option provides advantages in its form factor; however, it typically yields shorter range than the Whip and Dipole antenna options when transmitting outdoors. For more information, refer to the “XBee Antenna” appli-cation note located on MaxStream’s web site (http://www.maxstream.net/support/knowledgebase/article.php?kb=153).Table1‐01. SpecificationsoftheXBee/XBee‐PROOEMRFModulesSpecification XBee XBee-PROPerformanceIndoor/Urban Range up to 100 ft. (30 m) Up to 300’ (100 m)Outdoor RF line-of-sight Range up to 300 ft. (100 m) Up to 1 mile (1500 m)Transmit Power Output (software selectable) 1mW (0 dBm) 60 mW (18 dBm) conducted, 100 mW (20 dBm) EIRP*RF Data Rate 250,000 bps 250,000 bpsSerial Interface Data Rate(software selectable)1200 - 115200 bps(non-standard baud rates also supported)1200 - 115200 bps(non-standard baud rates also supported)Receiver Sensitivity -92 dBm (1% packet error rate) -100 dBm (1% packet error rate)Power RequirementsSupply Voltage 2.8 – 3.4 V 2.8 – 3.4 VTransmit Current (typical) 45mA (@ 3.3 V)If PL=0 (10dBm): 137mA(@3.3V), 139mA(@3.0V)PL=1 (12dBm): 155mA (@3.3V), 153mA(@3.0V)PL=2 (14dBm): 170mA (@3.3V), 171mA(@3.0V)PL=3 (16dBm): 188mA (@3.3V), 195mA(@3.0V)PL=4 (18dBm): 215mA (@3.3V), 227mA(@3.0V)Idle / Receive Current (typical) 50mA (@ 3.3 V) 55mA (@ 3.3 V)Power-down Current < 10 µA < 10 µAGeneralOperating Frequency ISM 2.4 GHz ISM 2.4 GHzDimensions 0.960” x 1.087” (2.438cm x 2.761cm) 0.960” x 1.297” (2.438cm x 3.294cm)Operating Temperature -40 to 85º C (industrial) -40 to 85º C (industrial)Antenna Options Integrated Whip, Chip or U.FL Connector Integrated Whip, Chip or U.FL ConnectorNetworking & SecuritySupported Network Topologies Point-to-point, Point-to-multipoint & Peer-to-peerNumber of Channels(software selectable) 16 Direct Sequence Channels 12 Direct Sequence ChannelsAddressing Options PAN ID, Channel and Addresses PAN ID, Channel and AddressesAgency ApprovalsUnited States (FCC Part 15.247) OUR-XBEE OUR-XBEEPROIndustry Canada (IC) 4214A XBEE 4214A XBEEPROEurope (CE)  ETSI ETSI (Max. 10 dBm transmit power output)*Japan n/a 005NYCA0378 (Max. 10 dBm transmit power output)**
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 6Chapter1‐XBee/XBee‐PROOEMRFModules1.3. Mechanical DrawingsFigure1‐01. MechanicaldrawingsoftheXBee/XBee‐PROOEMRFModules(antennaoptionsnotshown) TheXBeeandXBee‐PRORFModulesarepin‐for‐pincompatible.1.4. Mounting ConsiderationsThe XBee/XBee-PRO RF Module was designed to mount into a receptacle (socket) and therefore does not require any soldering when mounting it to a board. The XBee Development Kits contain RS-232 and USB interface boards which use two 20-pin receptacles to receive modules.Figure1‐02. XBeeModuleMountingtoanRS‐232InterfaceBoard.The receptacles used on MaxStream development boards are manufactured by Century Intercon-nect. Several other manufacturers provide comparable mounting solutions; however, MaxStream currently uses the following receptacles:• Through-hole single-row receptacles -  Samtec P/N: MMS-110-01-L-SV (or equivalent)• Surface-mount double-row receptacles -  Century Interconnect P/N: CPRMSL20-D-0-1 (or equivalent)• Surface-mount single-row receptacles -  Samtec P/N: SMM-110-02-SM-SMaxStream also recommends printing an outline of the module on the board to indicate the orienta-tion the module should be mounted.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 7Chapter1‐XBee/XBee‐PROOEMRFModules1.5. Pin SignalsFigure1‐03. XBee/XBee‐PRORFModulePinNumbers(topsidesshown‐shieldsonbottom)*FunctionisnotsupportedatthetimeofthisreleaseDesign Notes:• Minimum connections: VCC, GND, DOUT & DIN• Minimum connections for updating firmware: VCC, GND, DIN, DOUT, RTS & DTR• Signal Direction is specified with respect to the module• Module includes a 50k Ω pull-up resistor attached to RESET• Several of the input pull-ups can be configured using the PR command• Unused pins should be left disconnectedTable1‐02. PinAssignmentsfortheXBeeandXBee‐PROModules (Low‐assertedsignalsaredistinguishedwithahorizontallineabovesignalname.)Pin # Name Direction Description1 VCC - Power supply2 DOUT Output UART Data Out3 DIN / CONFIG   Input UART Data In4 DO8* Output Digital Output 85RESET   Input Module Reset (reset pulse must be at least 200 ns)6 PWM0 / RSSI Output PWM Output 0 / RX Signal Strength Indicator7 PWM1 Output PWM Output 18 [reserved] - Do not connect9DTR / SLEEP_RQ / DI8 Input Pin Sleep Control Line or Digital Input 810 GND - Ground11 AD4 / DIO4 Either Analog Input 4 or Digital I/O 412 CTS  / DIO7 Either Clear-to-Send Flow Control or Digital I/O 713 ON / SLEEP Output Module Status Indicator14 VREF Input Voltage Reference for A/D Inputs15 Associate / AD5 / DIO5 Either Associated Indicator, Analog Input 5 or Digital I/O 516 RTS / AD6 / DIO6 Either Request-to-Send Flow Control, Analog Input 6 or Digital I/O 617 AD3 / DIO3 Either Analog Input 3 or Digital I/O 318 AD2 / DIO2 Either Analog Input 2 or Digital I/O 219 AD1 / DIO1 Either Analog Input 1 or Digital I/O 120 AD0 / DIO0 Either Analog Input 0 or Digital I/O 0Pin 1Pin 10Pin 1Pin 10Pin 20Pin 11Pin 20Pin 11
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 8Chapter1‐XBee/XBee‐PROOEMRFModules1.6. Electrical CharacteristicsTable1‐03. DCCharacteristics(VCC=2.8‐3.4VDC)Symbol Characteristic Condition Min Typical Max UnitVIL Input Low Voltage All Digital Inputs - -  0.35 * VCC VVIH Input High Voltage All Digital Inputs 0.7 * VCC -   - VVOL Output Low Voltage IOL = 2 mA, VCC >= 2.7 V --0.5VVOH Output High Voltage IOH  = -2 mA, VCC >= 2.7 V VCC - 0.5 - - VIIIN Input Leakage Current VIN = VCC or GND, all inputs, per pin - 0.025 1 µAIIOZ High Impedance Leakage Current VIN = VCC or GND, all I/O High-Z, per pin - 0.025 1 µATX Transmit Current VCC = 3.3 V - 45(XBee) 215(PRO) -mARX Receive Current VCC = 3.3 V - 50(XBee) 55(PRO) -mAPWR-DWN Power-down Current SM parameter = 1 - < 10 - µATable1‐04. ADCCharacteristics(Operating)Symbol Characteristic Condition Min Typical Max UnitVREFH VREF - Analog-to-Digital converter reference range 2.08 - VDDAD VIREF VREF - Reference Supply Current Enabled - 200 - µADisabled or Sleep Mode - < 0.01 0.02 µAVINDC Analog Input Voltage11. Maximumelectricaloperatingrange,notvalidconversionrange.VSSAD - 0.3 -VDDAD + 0.3 VTable1‐05. ADCTiming/PerformanceCharacteristics11. AllACCURACYnumbersarebasedonprocessorandsystembeinginWAITstate(verylittleactivityandnoIOswitching)andthatadequatelow‐passfilteringispresentonanaloginputpins(filterwith0.01μFto0.1μFcapacitorbetweenanaloginputandVREFL).Failuretoobservetheseguidelinesmayresultinsystemormicrocontrollernoisecausingaccuracyerrorswhichwillvarybasedonboardlayoutandthetypeandmagnitudeoftheactivity.Datatransmissionandreceptionduringdataconversionmaycausesomedegradationofthesespecifications,dependingonthenumberandtimingofpackets.ItisadvisabletotesttheADCsinyourinstallationifbestaccuracyisrequired.Symbol Characteristic Condition Min Typical Max UnitRAS Source Impedance at Input22. RASistherealportionoftheimpedanceofthenetworkdrivingtheanaloginputpin.ValuesgreaterthanthisamountmaynotfullychargetheinputcircuitryoftheATDresultinginaccuracyerror.--10 kVAIN Analog Input Voltage33. AnaloginputmustbebetweenVREFLandVREFHforvalidconversion.ValuesgreaterthanVREFHwillconvertto$3FF.VREFL VREFH VRES Ideal Resolution (1 LSB)44. Theresolutionistheidealstepsizeor1LSB=(VREFH–VREFL)/10242.08V < VDDAD < 3.6V 2.031 - 3.516 mVDNL Differential Non-linearity55. Differentialnon‐linearityisthedifferencebetweenthecurrentcodewidthandtheidealcodewidth(1LSB).Thecurrentcodewidthisthedifferenceinthetransitionvoltagestoandfromthecurrentcode.- ±0.5 ±1.0 LSBINL Integral Non-linearity66. Integralnon‐linearityisthedifferencebetweenthetransitionvoltagetothecurrentcodeandtheadjustedidealtransitionvoltageforthecurrentcode.Theadjustedidealtransitionvoltageis(CurrentCode–1/2)*(1/((VREFH+EFS)–(VREFL+EZS))).- ±0.5 ±1.0 LSBEZS Zero-scale Error77. Zero‐scaleerroristhedifferencebetweenthetransitiontothefirstvalidcodeandtheidealtransitiontothatcode.TheIdealtransitionvoltagetoagivencodeis(Code–1/2)*(1/(VREFH–VREFL)).- ±0.4 ±1.0 LSBFFS Full-scale Error88. Full‐scaleerroristhedifferencebetweenthetransitiontothelastvalidcodeandtheidealtransitiontothatcode.Theidealtransitionvoltagetoagivencodeis(Code–1/2)*(1/(VREFH–VREFL)).- ±0.4 ±1.0 LSBEIL Input Leakage Error99. Inputleakageerroriserrorduetoinputleakageacrosstherealportionoftheimpedanceofthenetworkdrivingtheanalogpin.Reducingtheimpedanceofthenetworkreducesthiserror.- ±0.05 ±5.0 LSBETU Total Unadjusted Error1010.Totalunadjustederroristhedifferencebetweenthetransitionvoltagetothecurrentcodeandtheidealstraight‐linetrans‐ferfunction.Thismeasureoferrorincludesinherentquantizationerror(1/2LSB)andcircuiterror(differential,integral,zero‐scale,andfull‐scale)error.ThespecifiedvalueofETUassumeszeroEIL(noleakageorzerorealsourceimpedance).- ±1.1 ±2.5 LSB
©2007MaxStream,Inc. 92.RFModuleOperation2.1. Serial CommunicationsThe XBee/XBee-PRO OEM RF Modules interface to a host device through a logic-level asynchro-nous serial port. Through its serial port, the module can communicate with any logic and voltage compatible UART; or through a level translator to any serial device (For example: Through a Max-Stream proprietary RS-232 or USB interface board).2.1.1. UART Data FlowDevices that have a UART interface can connect directly to the pins of the RF module as shown in the figure below.Figure2‐01. SystemDataFlowDiagraminaUART‐interfacedenvironment (Low‐assertedsignalsdistinguishedwithhorizontallineoversignalname.)Serial DataData enters the module UART through the DI pin (pin 3) as an asynchronous serial signal. The sig-nal should idle high when no data is being transmitted.Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following figure illustrates the serial bit pattern of data passing through the module.Figure2‐02. UARTdatapacket0x1F(decimalnumberʺ31ʺ)astransmittedthroughtheRFmodule ExampleDataFormatis8‐N‐1(bits‐parity‐#ofstopbits)The module UART performs tasks, such as timing and parity checking, that are needed for data communications. Serial communications depend on the two UARTs to be configured with compati-ble settings (baud rate, parity, start bits, stop bits, data bits).
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 10Chapter2‐RFModuleOperation2.1.2. Transparent OperationBy default, XBee/XBee-PRO RF Modules operate in Transparent Mode. When operating in this mode, the modules act as a serial line replacement - all UART data received through the DI pin is queued up for RF transmission. When RF data is received, the data is sent out the DO pin.Serial-to-RF PacketizationData is buffered in the DI buffer until one of the following causes the data to be packetized and transmitted:If the module cannot immediately transmit (for instance, if it is already receiving RF data), the serial data is stored in the DI Buffer. The data is packetized and sent at any RO timeout or when 100 bytes (maximum packet size) are received.If the DI buffer becomes full, hardware or software flow control must be implemented in order to prevent overflow (loss of data between the host and module).2.1.3. API OperationAPI (Application Programming Interface) Operation is an alternative to the default Transparent Operation. The frame-based API extends the level to which a host application can interact with the networking capabilities of the module.When in API mode, all data entering and leaving the module is contained in frames that define operations or events within the module.Transmit Data Frames (received through the DI pin (pin 3)) include:• RF Transmit Data Frame• Command Frame (equivalent to AT commands)Receive Data Frames (sent out the DO pin (pin 2)) include:• RF-received data frame• Command response• Event notifications such as reset, associate, disassociate, etc.The API provides alternative means of configuring modules and routing data at the host applica-tion layer. A host application can send data frames to the module that contain address and payload information instead of using command mode to modify addresses. The module will send data frames to the application containing status packets; as well as source, RSSI and payload informa-tion from received data packets.The API operation option facilitates many operations such as the examples cited below:To implement API operations, refer to API sections [p54].1.  No serial characters are received for the amount of time determined by the RO (Packetiza-tion Timeout) parameter. If RO = 0, packetization begins when a character is received.2. The maximum number of characters that will fit in an RF packet (100) is received.3. The Command Mode Sequence (GT + CC + GT) is received. Any character buffered in the DI buffer before the sequence is transmitted.-> Transmitting data to multiple destinations without entering Command Mode-> Receive success/failure status of each transmitted RF packet-> Identify the source address of each received packet
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 11Chapter2‐RFModuleOperation2.1.4. Flow ControlFigure2‐03. InternalDataFlowDiagramDI (Data In) BufferWhen serial data enters the RF module through the DI pin (pin 3), the data is stored in the DI Buffer until it can be processed.Hardware Flow Control (CTS). When the DI buffer is 17 bytes away from being full; by default, the module de-asserts CTS (high) to signal to the host device to stop sending data [refer to D7 (DIO7 Configuration) parameter]. CTS is re-asserted after the DI Buffer has 34 bytes of memory available.How to eliminate the need for flow control:Case in which the DI Buffer may become full and possibly overflow:Refer to the RO (Packetization Timeout), BD (Interface Data Rate) and D7 (DIO7 Configuration) com-mand descriptions for more information.DO (Data Out) BufferWhen RF data is received, the data enters the DO buffer and is sent out the serial port to a host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost.Hardware Flow Control (RTS). If RTS is enabled for flow control (D6 (DIO6 Configuration) Parameter = 1), data will not be sent out the DO Buffer as long as RTS (pin 16) is de-asserted.Two cases in which the DO Buffer may become full and possibly overflow:Refer to the D6 (DIO6 Configuration) command description for more information.1. Send messages that are smaller than the DI buffer size.2. Interface at a lower baud rate [BD (Interface Data Rate) parameter] than the throughput data rate.If the module is receiving a continuous stream of RF data, any serial data that arrives on the DI pin is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the module is no longer receiving RF data in the network.1.    If the RF data rate is set higher than the interface data rate of the module, the module will receive data from the transmitting module faster than it can send the data to the host.2.    If the host does not allow the module to transmit data out from the DO buffer because of being held off by hardware or software flow control.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 12Chapter2‐RFModuleOperation2.2. ADC and Digital I/O Line SupportThe XBee/XBee-PRO RF Modules support ADC (Analog-to-digital conversion) and digital I/O line passing. The following pins support multiple functions:To enable ADC and DIO pin functions:2.2.1. I/O Data FormatI/O data begins with a header. The first byte of the header defines the number of samples forth-coming. A sample is comprised of input data and the inputs can contain either DIO or ADC. The last 2 bytes of the header (Channel Indicator) define which inputs are active. Each bit represents either a DIO line or ADC channel.Figure2‐04. HeaderSample data follows the header and the channel indicator frame is used to determine how to read the sample data. If any of the DIO lines are enabled, the first 2 bytes are the DIO data and the ADC data follows. ADC channel data is stored as an unsigned 10-bit value right-justified on a 16-bit boundary.Figure2‐05. SampleDataTable2‐01. Pinfunctionsandtheirassociatedpinnumbersandcommands AD=Analog‐to‐DigitalConverter,DIO=DigitalInput/Output Pinfunctionsnotapplicabletothissectionaredenotedwithin(parenthesis).Pin Function Pin# AT CommandAD0 / DIO0 20 D0AD1 / DIO1 19 D1AD2 / DIO2 18 D2AD3 / DIO3 / (COORD_SEL) 17 D3AD4 / DIO4 11 D4AD5 / DIO5 / (ASSOCIATE) 15 D5DIO6 / (RTS) 16 D6DIO7 / (CTS) 12 D7DI8 / (DTR) / (Sleep_RQ) 9 D8For ADC Support:  Set ATDn = 2For Digital Input support:  Set ATDn = 3For Digital Output Low support: Set ATDn = 4For Digital Output High support: Set ATDn = 5HeaderBit set to ‘1’ if channel is activeBytes 2 - 3 (Channel Indicator)na D8A0A1A2A3A4A5 D7 D0D1D2D3D4D5D6Byte 1Total number of samplesbit 15 bit 0Sample DataDIO Line Data is first (if enabled) ADC Line DataADCn MSB ADCn LSB7 0123456X 8XXXXXX
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 13Chapter2‐RFModuleOperation2.2.2. API SupportI/O data is sent out the UART using an API frame. All other data can be sent and received using Transparent Operation [refer to p10] or API framing if API mode is enabled (AP > 0).API Operations support two RX (Receive) frame identifiers for I/O data:• 0x82 for RX (Receive) Packet: 64-bit address I/O• 0x83 for RX (Receive) Packet: 16-bit address I/OThe API command header is the same as shown in the “RX (Receive) Packet: 64-bit Address” and “RX (Receive) Packet: 64-bit Address” API types [refer to p58]. RX data follows the format described in the I/O Data Format section [p12].Applicable Commands: AP (API Enable)2.2.3. Sleep SupportWhen an RF module wakes, it will always do a sample based on any active ADC or DIO lines. This allows sampling based on the sleep cycle whether it be Cyclic Sleep (SM parameter = 4 or 5) or Pin Sleep (SM = 1 or 2). To gather more samples when awake, set the IR (Sample Rate) parameter. For Cyclic Sleep modes: If the IR parameter is set, the module will stay awake until the IT (Sam-ples before TX) parameter is met. The module will stay awake for ST (Time before Sleep) time.Applicable Commands: IR (Sample Rate), IT (Samples before TX), SM (Sleep Mode), IC (DIO Change Detect)2.2.4. DIO Pin Change DetectWhen “DIO Change Detect” is enabled (using the IC command), DIO lines 0-7 are monitored. When a change is detected on a DIO line, the following will occur:Note: Change detect will not affect Pin Sleep wake-up. The D8 pin (DTR/Sleep_RQ/DI8) is the only line that will wake a module from Pin Sleep. If not all samples are collected, the module will still enter Sleep Mode after a change detect packet is sent.Applicable Commands: IC (DIO Change Detect), IT (Samples before TX)NOTE: Change detect is only supported when the Dx (DIOx Configuration) parameter equals 3,4 or 5.2.2.5. Sample Rate (Interval)The Sample Rate (Interval) feature allows enabled ADC and DIO pins to be read periodically on modules that are not configured to operate in Sleep Mode. When one of the Sleep Modes is enabled and the IR (Sample Rate) parameter set, the module will stay awake until IT (Samples before TX) samples have been collected.Once a particular pin is enabled, the appropriate sample rate must be chosen. The maximum sam-ple rate that can be achieved while using one A/D line is 1 sample/ms or 1 KHz (Note that the modem will not be able to keep up with transmission when IR & IT are equal to “1”).Applicable Commands: IR (Sample Rate), IT (Samples before TX), SM (Sleep Mode)1. An RF packet is sent with the updated DIO pin levels. This packet will not contain any ADC samples. 2. Any queued samples are transmitted before the change detect data. This may result in receiving a packet with less than IT (Samples before TX) samples.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 14Chapter2‐RFModuleOperation2.2.6. I/O Line PassingVirtual wires can be set up between XBee/XBee-PRO Modules. When an RF data packet is received that contains I/O data, the receiving module can be setup to update any enabled outputs (PWM and DIO) based on the data it receives.Note that I/O lines are mapped in pairs. For example: AD0 can only update PWM0 and DI5 can only update DO5). The default setup is for outputs not to be updated, which results in the I/O data being sent out the UART (refer to the IU (Enable I/O Output) command). To enable the outputs to be updated, the IA (I/O Input Address) parameter must be setup with the address of the module that has the appropriate inputs enabled. This effectively binds the outputs to a particular module’s input. This does not affect the ability of the module to receive I/O line data from other modules - only its ability to update enabled outputs. The IA parameter can also be setup to accept I/O data for output changes from any module by setting the IA parameter to 0xFFFF. When outputs are changed from their non-active state, the module can be setup to return the out-put level to it non-active state. The timers are set using the Tn (Dn Output Timer) and PT (PWM Output Timeout) commands. The timers are reset every time a valid I/O packet (passed IA check) is received. The IC (Change Detect) and IR (Sample Rate) parameters can be setup to keep the output set to their active output if the system needs more time than the timers can handle.Note: DI8 can not be used for I/O line passing. Applicable Commands: IA (I/O Input Address), Tn (Dn Output Timeout), P0 (PWM0 Configura-tion), P1 (PWM1 Configuration), M0 (PWM0 Output Level), M1 (PWM1 Output Level), PT (PWM Output Timeout), RP (RSSSI PWM Timer)2.2.7. Configuration ExampleAs an example for a simple A/D link, a pair of RF modules could be set as follows:These settings configure the remote module to sample AD0 and AD1 once each every 20 ms. It  then buffers 5 samples each before sending them back to the base module. The base should then receive a 32-Byte transmission (20 Bytes data and 12 Bytes framing)  every 100 ms.Remote ConfigurationDL = 0x1234MY = 0x5678D0 = 2D1 = 2IR = 0x14IT = 5Base ConfigurationDL = 0x5678MY = 0x1234P0 = 2P1 = 2IU = 1IA = 0x5678 (or 0xFFFF)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 15Chapter2‐RFModuleOperation2.3. XBee/XBee-PRO NetworksThe following IEEE 802.15.4 network types are supported by the XBee/XBee-PRO RF modules:•NonBeacon• NonBeacon (w/ Coordinator)The following terms will be used to explicate the network operations:2.3.1. NonBeaconBy default, XBee/XBee-PRO RF Modules are configured to support NonBeacon communications. NonBeacon systems operate within a Peer-to-Peer network topology and therefore are not depen-dent upon Master/Slave relationships. This means that modules remain synchronized without use of master/server configurations and each module in the network shares both roles of master and slave. MaxStream's peer-to-peer architecture features fast synchronization times and fast cold start times. This default configuration accommodates a wide range of RF data applications.Figure2‐06. NonBeaconPeer‐to‐PeerArchitectureA peer-to-peer network can be established by configuring each module to operate as an End Device (CE = 0), disabling End Device Association on all modules (A1 = 0) and setting ID and CH parameters to be identical across the network.2.3.2. NonBeacon (w/ Coordinator)A device is configured as a Coordinator by setting the CE (Coordinator Enable) parameter to “1”. Coordinator power-up is governed by the A2 (Coordinator Association) parameter.In a NonBeacon (w/ Coordinator) system, the Coordinator can be configured to use direct or indi-rect transmissions. If the SP (Cyclic Sleep Period) parameter is set to “0”, the Coordinator will send data immediately. Otherwise, the SP parameter determines the length of time the Coordinator will retain the data before discarding it. Generally, SP (Cyclic Sleep Period) and ST (Time before Sleep) parameters should be set to match the SP and ST settings of the End Devices.Association plays a critical role in the implementation of a NonBeacon (w/ Coordinator) system. Refer to the Association section [next page] for more information.Table2‐02. TermsanddefinitionsTerm DefinitionPAN Personal Area Network - A data communication network that includes one or more End Devices and optionally a Coordinator.Coordinator A Full-function device (FFD) that provides network synchronization by polling nodes [NonBeacon (w/ Coordinator) networks only]End Device When in the same network as a Coordinator - RF modules that rely on a Coordinator for synchronization and can be put into states of sleep for low-power applications.Association The establishment of membership between End Devices and a Coordinator. Association is only applicable in NonBeacon (w/Coordinator) networks.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 16Chapter2‐RFModuleOperation2.3.3. AssociationAssociation is the establishment of membership between End Devices and a Coordinator and is only applicable in NonBeacon (w/ Coordinator) networks. The establishment of membership is useful in scenarios that require a central unit (Coordinator) to relay messages to or gather data from several remote units (End Devices), assign channels or assign PAN IDs.An RF data network that consists of one Coordinator and one or more End Devices forms a PAN (Personal Area Network). Each device in a PAN has a PAN Identifier [ID (PAN ID) parameter]. PAN IDs must be unique to prevent miscommunication between PANs. The Coordinator PAN ID is set using the ID (PAN ID) and A2 (Coordinator Association) commands.An End Device can associate to a Coordinator without knowing the address, PAN ID or channel of the Coordinator. The A1 (End Device Association) parameter bit fields determine the flexibility of an End Device during association. The A1 parameter can be used for an End Device to dynamically set its destination address, PAN ID and/or channel.Coordinator / End Device Setup and OperationTo configure a module to operate as a Coordinator, set the CE (Coordinator Enable) parameter to ‘1’. Set the CE parameter of End Devices to ‘0’ (default). Coordinator and End Devices should con-tain matching firmware versions.NonBeacon (w/ Coordinator) SystemsIn a NonBeacon (w/ Coordinator) system, the Coordinator can be configured to use direct or indi-rect transmissions. If the SP (Cyclic Sleep Period) parameter is set to ‘0’, the Coordinator will send data immediately. Otherwise, the SP parameter determines the length of time the Coordinator will retain the data before discarding it. Generally, SP (Cyclic Sleep Period) and ST (Time before Sleep) parameters should be set to match the SP and ST settings of the End Devices.Coordinator Power-upCoordinator power-up is governed by the A2 (Coordinator Association) command. On power-up, the Coordinator undergoes the following sequence of events:1. Check A2 parameter- Reassign_PANID FlagSet (bit 0 = 1) - The Coordinator issues an Active Scan. The Active Scan selects one channel and transmits a BeaconRequest command to the broadcast address (0xFFFF) and broadcast PAN ID (0xFFFF). It then listens on that channel for beacons from any Coordinator operating on that channel. The listen time on each channel is determined by the SD (Scan Duration) param-eter value.Once the time expires on that channel, the Active Scan selects another channel and again transmits the BeaconRequest as before. This process continues until all channels have been scanned, or until 5 PANs have been discovered. When the Active Scan is complete, the results include a list of PAN IDs and Channels that are being used by other PANs. This list is used to assign an unique PAN ID to the new Coordinator. The ID parameter will be retained if it is not found in the Active Scan results. Otherwise, the ID (PAN ID) parameter setting will be updated to a PAN ID that was not detected.Not Set (bit 0 = 0) - The Coordinator retains its ID setting. No Active Scan is performed.For example: If the PAN ID of a Coordinator is known, but the operating channel is not; the A1 command on the End Device should be set to enable the ‘Auto_Associate’ and ‘Reassign_Channel’ bits. Additionally, the ID parameter should be set to match the PAN ID of the associated Coordinator.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 17Chapter2‐RFModuleOperation2. Check A2 parameter - Reassign_Channel Flag (bit 1)Set (bit 1 = 1) - The Coordinator issues an Energy Scan. The Energy Scan selects one channel and scans for energy on that channel. The duration of the scan is specified by the SD (Scan Duration) parameter. Once the scan is completed on a channel, the Energy Scan selects the next channel and begins a new scan on that channel. This process continues until all channels have been scanned. When the Energy Scan is complete, the results include the maximal energy values detected on each channel. This list is used to determine a channel where the least energy was detected. If an Active Scan was performed (Reassign_PANID Flag set), the channels used by the detected PANs are eliminated as possible channels. Thus, the results of the Energy Scan and the Active Scan (if performed) are used to find the best channel (channel with the least energy that is not used by any detected PAN). Once the best channel has been selected, the CH (Channel) param-eter value is updated to that channel.Not Set (bit 1 = 0)  - The Coordinator retains its CH setting. An Energy Scan is not performed.3. Start CoordinatorThe Coordinator starts on the specified channel (CH parameter) and PAN ID (ID parameter). Note, these may be selected in steps 1 and/or 2 above. The Coordinator will only allow End Devices to associate to it if the A2 parameter “AllowAssociation” flag is set. Once the Coordina-tor has successfully started, the Associate LED will blink 1 time per second. (The LED is solid if the Coordinator has not started.)4. Coordinator ModificationsOnce a Coordinator has started:  Modifying the A2 (Reassign_Channel or Reassign_PANID bits), ID, CH or MY parameters will cause the Coordinator’s MAC to reset (The Coordinator RF module (including volatile RAM) is not reset). Changing the A2 AllowAssociation bit will not reset the Coordinator’s MAC. In a non-beaconing system, End Devices that associated to the Coordinator prior to a MAC reset will have knowledge of the new settings on the Coordinator. Thus, if the Coordinator were to change its ID, CH or MY settings, the End Devices would no longer be able to communicate with the non-beacon Coordinator. Once a Coordinator has started, the ID, CH, MY or A2 (Reassign_Channel or Reassign_PANID bits) should not be changed.End Device Power-upEnd Device power-up is governed by the A1 (End Device Association) command. On power-up, the End Device undergoes the following sequence of events:1. Check A1 parameter - AutoAssociate BitSet (bit 2 = 1) - End Device will attempt to associate to a Coordinator. (refer to steps 2-3).Not Set (bit 2 = 0) - End Device will not attempt to associate to a Coordinator. The End Device will operate as specified by its ID, CH and MY parameters. Association is considered complete and the Associate LED will blink quickly (5 times per second). When the AutoAssociate bit is not set, the remaining steps (2-3) do not apply.2. Discover Coordinator (if Auto-Associate Bit Set)The End Device issues an Active Scan. The Active Scan selects one channel and transmits a BeaconRequest command to the broadcast address (0xFFFF) and broadcast PAN ID (0xFFFF). It then listens on that channel for beacons from any Coordinator operating on that channel. The listen time on each channel is determined by the SD parameter. Once the time expires on that channel, the Active Scan selects another channel and again transmits the BeaconRequest command as before. This process continues until all channels have been scanned, or until 5 PANs have been discovered. When the Active Scan is complete, the results include a list of PAN IDs and Channels that are being used by detected PANs.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 18Chapter2‐RFModuleOperationThe End Device selects a Coordinator to associate with according to the A1 parameter “Reassign_PANID” and “Reassign_Channel” flags:Reassign_PANID Bit Set (bit 0 = 1)- End Device can associate with a PAN with any ID value. Reassign_PANID Bit Not Set (bit 0 = 0) - End Device will only associate with a PAN whose ID setting matches the ID setting of the End Device. Reassign_Channel Bit Set (bit 1 = 1) - End Device can associate with a PAN with any CH value.Reassign_Channel Bit Not Set (bit 1 = 0)- End Device will only associate with a PAN whose CH setting matches the CH setting of the End Device. After applying these filters to the discovered Coordinators, if multiple candidate PANs exist, the End Device will select the PAN whose transmission link quality is the strongest. If no valid Coor-dinator is found, the End Device will either go to sleep (as dictated by its SM (Sleep Mode) parameter) or retry Association. Note - An End Device will also disqualify Coordinators if they are not allowing association (A2 - AllowAssociation bit); or, if the Coordinator is not using the same NonBeacon scheme as the End Device. (They must both be programmed with NonBeacon code.)3. Associate to Valid CoordinatorOnce a valid Coordinator is found (step 2), the End Device sends an AssociationRequest mes-sage to the Coordinator. It then waits for an AssociationConfirmation to be sent from the Coor-dinator. Once the Confirmation is received, the End Device is Associated and the Associate LED will blink rapidly (2 times per second). The LED is solid if the End Device has not associated.4. End Device Changes once an End Device has associatedChanging A1, ID or CH parameters will cause the End Device to disassociate and restart the Association procedure.If the End Device fails to associate, the AI command can give some indication of the failure.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 19Chapter2‐RFModuleOperation2.4. XBee/XBee-PRO AddressingEvery RF data packet sent over-the-air contains a Source Address and Destination Address field in its header. The RF module conforms to the 802.15.4 specification and supports both short 16-bit addresses and long 64-bit addresses. A unique 64-bit IEEE source address is assigned at the fac-tory and can be read with the SL (Serial Number Low) and SH (Serial Number High) commands. Short addressing must be configured manually. A module will use its unique 64-bit address as its Source Address if its MY (16-bit Source Address) value is “0xFFFF” or “0xFFFE”.To send a packet to a specific module using 64-bit addressing: Set Destination Address (DL + DH) to match the Source Address (SL + SH) of the intended destination module. To send a packet to a specific module using 16-bit addressing: Set DL (Destination Address Low) parameter to equal the MY parameter and set the DH (Destination Address High) parameter to ‘0’.2.4.1. Unicast ModeBy default, the RF module operates in Unicast Mode. Unicast Mode is the only mode that supports retries. While in this mode, receiving modules send an ACK (acknowledgement) of RF packet reception to the transmitter. If the transmitting module does not receive the ACK, it will re-send the packet up to three times or until the ACK is received.Short 16-bit addresses. The module can be configured to use short 16-bit addresses as the Source Address by setting (MY < 0xFFFE). Setting the DH parameter (DH = 0) will configure the Destination Address to be a short 16-bit address (if DL < 0xFFFE). For two modules to communi-cate using short addressing, the Destination Address of the transmitter module must match the MY parameter of the receiver.The following table shows a sample network configuration that would enable Unicast Mode com-munications using short 16-bit addresses.Long 64-bit addresses. The RF module’s serial number (SL parameter concatenated to the SH parameter) can be used as a 64-bit source address when the MY (16-bit Source Address) parame-ter is disabled. When the MY parameter is disabled (set MY = 0xFFFF or 0xFFFE), the module’s source address is set to the 64-bit IEEE address stored in the SH and SL parameters.When an End Device associates to a Coordinator, its MY parameter is set to 0xFFFE to enable 64-bit addressing. The 64-bit address of the module is stored as SH and SL parameters. To send a packet to a specific module, the Destination Address (DL + DH) on one module must match the Source Address (SL + SH) of the other.2.4.2. Broadcast ModeAny RF module within range will accept a packet that contains a broadcast address. When config-ured to operate in Broadcast Mode, receiving modules do not send ACKs (Acknowledgements) and transmitting modules do not automatically re-send packets as is the case in Unicast Mode. To send a broadcast packet to all modules regardless of 16-bit or 64-bit addressing, set the desti-nation addresses of all the modules as shown below.Sample Network Configuration (All modules in the network):• DL (Destination Low Address) = 0x0000FFFF• DH (Destination High Address) = 0x00000000 (default value)NOTE: When programming the module, parameters are entered in hexadecimal notation (without the “0x” prefix). Leading zeros may be omitted.Table2‐03. SampleUnicastNetworkConfiguration(using16‐bitaddressing)Parameter RF Module 1 RF Module 2MY (Source Address) 0x01 0x02DH (Destination Address High) 0 0DL (Destination Address Low) 0x02 0x01
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 20Chapter2‐RFModuleOperation2.5. Modes of OperationXBee/XBee-PRO RF Modules operate in five modes.Figure2‐07. ModesofOperation2.5.1. Idle ModeWhen not receiving or transmitting data, the RF module is in Idle Mode. The module shifts into the other modes of operation under the following conditions:• Transmit Mode (Serial data is received in the DI Buffer)• Receive Mode (Valid RF data is received through the antenna)• Sleep Mode (Sleep Mode condition is met)• Command Mode (Command Mode Sequence is issued)2.5.2. Transmit/Receive ModesRF Data PacketsEach transmitted data packet contains a Source Address and Destination Address field. The Source Address matches the address of the transmitting module as specified by the MY (Source Address) parameter (if MY >= 0xFFFE), the SH (Serial Number High) parameter or the SL (Serial Number Low) parameter. The <Destination Address> field is created from the DH (Destination Address High) and DL (Destination Address Low) parameter values. The Source Address and/or Destination Address fields will either contain a 16-bit short or long 64-bit long address. The RF data packet structure follows the 802.15.4 specification.[Refer to the XBee/XBee-PRO Addressing section for more information]Direct and Indirect TransmissionThere are two methods to transmit data:• Direct Transmission - data is transmitted immediately to the Destination Address• Indirect Transmission - A packet is retained for a period of time and is only transmitted after the destination module (Source Address = Destination Address) requests the data. Indirect Transmissions can only occur on a Coordinator. Thus, if all nodes in a network are End Devices, only Direct Transmissions will occur. Indirect Transmissions are useful to ensure packet delivery to a sleeping node. The Coordinator currently is able to retain up to 2 indirect messages.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 21Chapter2‐RFModuleOperationDirect TransmissionA NonBeaconing Coordinator can be configured to use only Direct Transmission by setting the SP (Cyclic Sleep Period) parameter to “0”. Also, a NonBeaconing Coordinator using indirect transmis-sions will revert to direct transmission if it knows the destination module is awake.To enable this behavior, the ST (Time before Sleep) value of the Coordinator must be set to match the ST value of the End Device. Once the End Device either transmits data to the Coordinator or polls the Coordinator for data, the Coordinator will use direct transmission for all subsequent data transmissions to that module address until ST time (or number of beacons) occurs with no activity (at which point it will revert to using indirect transmissions for that module address). “No activity” means no transmission or reception of messages with a specific address. Global messages will not reset the ST timer.Indirect TransmissionTo configure Indirect Transmissions in a PAN (Personal Area Network), the SP (Cyclic Sleep Period) parameter value on the Coordinator must be set to match the longest sleep value of any End Device. The SP parameter represents time in NonBeacon systems and beacons in Beacon-enabled systems. The sleep period value on the Coordinator determines how long (time or number of bea-cons) the Coordinator will retain an indirect message before discarding it.In NonBeacon networks, an End Device must poll the Coordinator once it wakes from Sleep to determine if the Coordinator has an indirect message for it. For Cyclic Sleep Modes, this is done automatically every time the module wakes (after SP time). For Pin Sleep Modes, the A1 (End Device Association) parameter value must be set to enable Coordinator polling on pin wake-up. Alternatively, an End Device can use the FP (Force Poll) command to poll the Coordinator as needed.CCA (Clear Channel Assessment)Prior to transmitting a packet, a CCA (Clear Channel Assessment) is performed on the channel to determine if the channel is available for transmission. The detected energy on the channel is com-pared with the CA (Clear Channel Assessment) parameter value. If the detected energy exceeds the CA parameter value, the packet is not transmitted. Also, a delay is inserted before a transmission takes place. This delay is settable using the RN (Backoff Exponent) parameter. If RN is set to “0”, then there is no delay before the first CCA is per-formed. The RN parameter value is the equivalent of the “minBE” parameter in the 802.15.4 spec-ification. The transmit sequence follows the 802.15.4 specification.By default, the MM (MAC Mode) parameter = 0. On a CCA failure, the module will attempt to re-send the packet up to two additional times.When in Unicast packets with RR (Retries) = 0, the module will execute two CCA retries. Broadcast packets always get two CCA retries.AcknowledgementIf the transmission is not a broadcast message, the module will expect to receive an acknowledge-ment from the destination node. If an acknowledgement is not received, the packet will be resent up to 3 more times. If the acknowledgement is not received after all transmissions, an ACK failure is recorded.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 22Chapter2‐RFModuleOperation2.5.3. Sleep ModeSleep Modes enable the RF module to enter states of low-power consumption when not in use. In order to enter Sleep Mode, one of the following conditions must be met (in addition to the module having a non-zero SM parameter value):• Sleep_RQ (pin 9) is asserted.• The module is idle (no data transmission or reception) for the amount of time defined by the ST (Time before Sleep) parameter. [NOTE: ST is only active when SM = 4-5.]The SM command is central to setting Sleep Mode configurations. By default, Sleep Modes are dis-abled (SM = 0) and the module remains in Idle/Receive Mode. When in this state, the module is constantly ready to respond to serial or RF activity.Higher Voltages. Sleep Mode current consumption is highly sensitive to voltage. Voltages above 3.0V will cause much higher current consumption.Pin/Host-controlled Sleep ModesThe transient current when waking from pin sleep (SM = 1 or 2) does not exceed the idle current of the module. The current ramps up exponentially to its idle current.Pin Hibernate (SM = 1)• Pin/Host-controlled• Typical power-down current: < 10 µA (@3.0 VCC)• Wake-up time: 13.2 msecPin Hibernate Mode minimizes quiescent power (power consumed when in a state of rest or inac-tivity). This mode is voltage level-activated; when Sleep_RQ is asserted, the module will finish any transmit, receive or association activities, enter Idle Mode and then enter a state of sleep. The module will not respond to either serial or RF activity while in pin sleep.To wake a sleeping module operating in Pin Hibernate Mode, de-assert Sleep_RQ (pin 9). The module will wake when Sleep_RQ is de-asserted and is ready to transmit or receive when the CTS line is low. When waking the module, the pin must be de-asserted at least two 'byte times' after CTS goes low. This assures that there is time for the data to enter the DI buffer.Table2‐04. SleepModeConfigurationsSleep Mode Setting Transition into Sleep Mode Transition out of Sleep Mode (wake) Characteristics RelatedCommands PowerConsumptionPin Hibernate (SM = 1) Assert (high) Sleep_RQ (pin 9) De-assert (low) Sleep_RQ Pin/Host-controlled / NonBeacon systems only / Lowest Power (SM) < 10 µA (@3.0 VCC)Pin Doze (SM = 2) Assert (high) Sleep_RQ (pin 9) De-assert (low) Sleep_RQ Pin/Host-controlled / NonBeacon systems only /  Fastest wake-up (SM) < 50 µACyclic Sleep (SM = 4 - 5)Automatic transition to Sleep Mode as defined by the SM (Sleep Mode) and ST (Time before Sleep) parameters.Transition occurs after the cyclic sleep time interval elapses. The time interval is defined by the SP (Cyclic Sleep Period) parameter.RF module wakes in pre-determined time intervals to detect if RF data is present / When SM = 5, NonBeacon systems only(SM), SP, ST < 50 µA when sleepingTable2‐05. SampleSleepModeCurrentsXBee XBee-PROVcc (V) SM=1 SM=2 SM=4,5 SM=1 SM=2 SM=4,52.8–3.0 <3 µA <35uA <34uA  <4uA <34uA <34uA3.1   8uA  37mA  36uA  12uA  39uA  37uA3.2  32uA  48uA  49uA  45uA  60uA  55uA3.3 101uA  83uA  100uA 130uA 115uA 120uA3.4 255uA 170uA 240uA 310uA 260uA 290uA
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 23Chapter2‐RFModuleOperationPin Doze (SM = 2)• Pin/Host-controlled• Typical power-down current: < 50 µA• Wake-up time: 2 msecPin Doze Mode functions as does Pin Hibernate Mode; however, Pin Doze features faster wake-up time and higher power consumption.To wake a sleeping module operating in Pin Doze Mode, de-assert Sleep_RQ (pin 9). The module will wake when Sleep_RQ is de-asserted and is ready to transmit or receive when the CTS line is low. When waking the module, the pin must be de-asserted at least two 'byte times' after CTS goes low. This assures that there is time for the data to enter the DI buffer.Cyclic Sleep ModesCyclic Sleep Remote (SM = 4)• Typical Power-down Current: < 50 µA (when asleep)• Wake-up time: 2 msecThe Cyclic Sleep Modes allow modules to periodically check for RF data. When the SM parameter is set to ‘4’, the module is configured to sleep, then wakes once a cycle to check for data from a module configured as a Cyclic Sleep Coordinator (SM = 0, CE = 1). The Cyclic Sleep Remote sends a poll request to the coordinator at a specific interval set by the SP (Cyclic Sleep Period) parame-ter. The coordinator will transmit any queued data addressed to that specific remote upon receiv-ing the poll request. If no data is queued for the remote, the coordinator will not transmit and the remote will return to sleep for another cycle. If queued data is transmitted back to the remote, it will stay awake to allow for back and forth communication until the ST (Time before Sleep) timer expires. Also note that CTS will go low each time the remote wakes, allowing for communication initiated by the remote host if desired. Cyclic Sleep Remote with Pin Wake-up (SM = 5) Use this mode to wake a sleeping remote module through either the RF interface or by the de-assertion of Sleep_RQ for event-driven communications. The cyclic sleep mode works as described above (Cyclic Sleep Remote) with the addition of a pin-controlled wake-up at the remote module. The Sleep_RQ pin is edge-triggered, not level-triggered. The module will wake when a low is detected then set CTS low as soon as it is ready to transmit or receive. Any activity will reset the ST (Time before Sleep) timer so the module will go back to sleep only after  there is no activity for the duration of the timer. Once the module wakes (pin-controlled), further pin activity is ignored. The module transitions back into sleep according to the ST time regardless of the state of the pin.[Cyclic Sleep Coordinator (SM = 6)] • Typical current = Receive current• Always awakeNOTE: The SM=6 parameter value exists solely for backwards compatibility with firmware version 1.x60. If backwards compatibility with the older firmware version is not required, always use the CE (Coordinator Enable) command to configure a module as a Coordinator.This mode configures a module to wake cyclic sleeping remotes through RF interfacing. The Coor-dinator will accept a message addressed to a specific remote 16 or 64-bit address and hold it in a buffer until the remote wakes and sends a poll request. Messages not sent directly (buffered and requested) are called "Indirect messages". The Coordinator only queues one indirect message at a time. The Coordinator will hold the indirect message for a period 2.5 times the sleeping period indicated by the SP (Cyclic Sleep Period) parameter. The Coordinator's SP parameter should be set to match the value used by the remotes.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 24Chapter2‐RFModuleOperation2.5.4. Command ModeTo modify or read RF Module parameters, the module must first enter into Command Mode - a state in which incoming characters are interpreted as commands. Two Command Mode options are supported: AT Command Mode [refer to section below] and API Command Mode [p54].AT Command ModeTo Enter AT Command Mode:Default AT Command Mode Sequence (for transition to Command Mode):• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]• Input three plus characters (“+++”) within one second [CC (Command Sequence Character) parameter = 0x2B.]• No characters sent for one second [GT (Guard Times) parameter = 0x3E8]All of the parameter values in the sequence can be modified to reflect user preferences.NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the ‘Baud’ setting on the “PC Settings” tab matches the interface data rate of the RF module. By default, the BD parameter = 3 (9600 bps).To Send AT Commands:Figure2‐08.SyntaxforsendingATCommandsTo read a parameter value stored in the RF module’s register, omit the parameter field.The preceding example would change the RF module Destination Address (Low) to “0x1F”. To store the new value to non-volatile (long term) memory, subsequently send the WR (Write) command.For modified parameter values to persist in the module’s registry after a reset, changes must be saved to non-volatile memory using the WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is reset.System Response. When a command is sent to the module, the module will parse and execute the command. Upon successful execution of a command, the module returns an “OK” message. If execution of a command results in an error, the module returns an “ERROR” message.To Exit AT Command Mode:For an example of programming the RF module using AT Commands and descriptions of each config-urable parameter, refer to the RF Module Configuration chapter [p25].Send the 3-character command sequence “+++” and observe guard times before and after the command characters. [Refer to the “Default AT Command Mode Sequence” below.]Send AT commands and parameters using the syntax shown below.1.    Send the ATCN (Exit Command Mode) command (followed by a carriage return).       [OR]2.    If no valid AT Commands are received within the time specified by CT (Command Mode Timeout) Command, the RF module automatically returns to Idle Mode.
©2007MaxStream,Inc. 253.RFModuleConfiguration3.1. Programming the RF ModuleRefer to the Command Mode section [p24] for more information about entering Command Mode, sending AT commands and exiting Command Mode. For information regarding module program-ming using API Mode, refer to the API Operation sections [p54].3.1.1. Programming ExamplesSetupSample Configuration: Modify RF Module Destination AddressSample Configuration: Restore RF Module DefaultsThe programming examples in this section require the installation of MaxStream's X-CTU Soft-ware and a serial connection to a PC. (MaxStream stocks RS-232 and USB boards to facilitate interfacing with a PC.)1. Install MaxStream's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file. (The file is located on the MaxStream CD and under the 'Software' section of the following web page: www.maxstream.net/support/downloads.php)2. Mount the RF module to an interface board, then connect the module assembly to a PC.3. Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity set-tings of the Com Port match those of the RF module.NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the ‘Baud’ setting on the ‘PC Settings’ tab matches the interface data rate of the RF mod-ule. By default, the BD parameter = 3 (which corresponds to 9600 bps).Example: Utilize the X-CTU “Terminal” tab to change the RF module's DL (Destination Address Low) parameter and save the new address to non-volatile memory.After establishing a serial connection between the RF module and a PC [refer to the 'Setup' sec-tion above], select the “Terminal” tab of the X-CTU Software and enter the following command lines (‘CR’ stands for carriage return):Method 1 (One line per command)Send AT Command +++ ATDL <Enter> ATDL1A0D <Enter> ATWR <Enter> ATCN <Enter>System Response OK <CR> (Enter into Command Mode) {current value} <CR> (Read Destination Address Low) OK <CR> (Modify Destination Address Low) OK <CR> (Write to non-volatile memory) OK <CR> (Exit Command Mode)Method 2 (Multiple commands on one line)Send AT Command +++ ATDL <Enter> ATDL1A0D,WR,CN <Enter>System Response OK <CR> (Enter into Command Mode) {current value} <CR> (Read Destination Address Low) OK<CR> OK<CR> OK<CR>Example: Utilize the X-CTU “Modem Configuration” tab to restore default parameter values.After establishing a connection between the module and a PC [refer to the 'Setup' section above], select the “Modem Configuration” tab of the X-CTU Software.1.    Select the 'Read' button.2.    Select the 'Restore' button.Refertothe‘X‐CTU’sec‐tionoftheDevelop‐mentGuide[AppendixB]formoreinformationregardingtheX‐CTUconfigurationsoftware.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 26Chapter3‐RFModuleConfiguration3.2. Command Reference TablesXBee/XBee-PRO RF Modules expect numerical values in hexadecimal. Hexadecimal values are des-ignated by a “0x” prefix. Decimal equivalents are designated by a “d” suffix. Commands are con-tained within the following command categories (listed in the order that their tables appear):•Special• Networking & Security• RF Interfacing• Sleep (Low Power)• Serial Interfacing•I/O Settings•Diagnostics• AT Command OptionsAll modules within a PAN should operate using the same firmware version.Special*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)Networking & Security Table3‐01. XBee‐PROCommands‐SpecialAT Command Command Category Name and Description Parameter Range DefaultWR SpecialWrite. Write parameter values to non-volatile memory so that parameter modifications persist through subsequent power-up or reset. Note: Once WR is issued, no additional characters should be sent to the module until after the response "OK\r" is received.--RE Special Restore Defaults. Restore module parameters to factory defaults. - -FR ( v1.x80*) Special Software Reset. Responds immediately with an OK then performs a hard reset ~100ms later. --Table3‐02. XBee/XBee‐PROCommands‐Networking&Security(Sub‐categoriesdesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range DefaultCH Networking {Addressing} Channel. Set/Read the channel number used for transmitting and receiving data between RF modules (uses 802.15.4 protocol channel numbers). 0x0B - 0x1A (XBee)             0x0C - 0x17 (XBee-PRO) 0x0C (12d)ID Networking {Addressing} PAN ID. Set/Read the PAN (Personal Area Network) ID. Use 0xFFFF to broadcast messages to all PANs. 0 - 0xFFFF 0x3332 (13106d)DH Networking {Addressing}Destination Address High. Set/Read the upper 32 bits of the 64-bit destination address. When combined with DL, it defines the destination address used for transmission. To transmit using a 16-bit address, set DH parameter to zero and DL less than 0xFFFF. 0x000000000000FFFF is the broadcast address for the PAN.0 - 0xFFFFFFFF 0DL Networking {Addressing}Destination Address Low. Set/Read the lower 32 bits of the 64-bit destination address. When combined with DH, DL defines the destination address used for transmission. To transmit using a 16-bit address, set DH parameter to zero and DL less than 0xFFFF. 0x000000000000FFFF is the broadcast address for the PAN.0 - 0xFFFFFFFF 0MY Networking {Addressing}16-bit Source Address. Set/Read the RF module 16-bit source address. Set MY = 0xFFFF to disable reception of packets with 16-bit addresses. 64-bit source address (serial number) and broadcast address (0x000000000000FFFF) is always enabled. 0 - 0xFFFF 0SH Networking {Addressing} Serial Number High. Read high 32 bits of the RF module's unique IEEE 64-bit address. 64-bit source address is always enabled. 0 - 0xFFFFFFFF [read-only] Factory-setSL Networking {Addressing} Serial Number Low. Read low 32 bits of the RF module's unique IEEE 64-bit address. 64-bit source address is always enabled. 0 - 0xFFFFFFFF [read-only] Factory-setRR ( v1.xA0*) Networking {Addressing}XBee Retries. Set/Read the maximum number of retries the module will execute in addition to the 3 retries provided by the 802.15.4 MAC. For each XBee retry, the 802.15.4 MAC can execute up to 3 retries. 0 - 6 0RN Networking {Addressing}Random Delay Slots. Set/Read the minimum value of the back-off exponent in the CSMA-CA algorithm that is used for collision avoidance. If RN = 0, collision avoidance is disabled during the first iteration of the algorithm (802.15.4 - macMinBE). 0 - 3 [exponent] 0MM ( v1.x80*) Networking {Addressing}MAC Mode. Set/Read MAC Mode value. MAC Mode enables/disables the use of a MaxStream header in the 802.15.4 RF packet. When Mode 0 is enabled (MM=0), duplicate packet detection is enabled as well as certain AT commands. Modes 1 and 2 are strict 802.15.4 modes.0 - 2 0 = MaxStream Mode 1 = 802.15.4 (no ACKs) 2 = 802.15.4 (with ACKs)0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 27Chapter3‐RFModuleConfigurationNI ( v1.x80*) Networking {Identification}Node Identifier. Stores a string identifier. The register only accepts printable ASCII data. A string can not start with a space. Carriage return ends command. Command will automatically end when maximum bytes for the string have been entered. This string is returned as part of the ND (Node Discover) command. This identifier is also used with the DN (Destination Node) command. 20-character ASCII string -ND ( v1.x80*) Networking {Identification}Node Discover. Discovers and reports all RF modules found. The following information is reported for each module discovered (the example cites use of Transparent operation (AT command format) - refer to the long ND command description regarding differences between Transparent and API operation). MY<CR> SH<CR> SL<CR> DB<CR> NI<CR><CR>The amount of time the module allows for responses is determined by the NT parameter. In Transparent operation, command completion is designated by a <CR> (carriage return). ND also accepts a Node Identifier as a parameter. In this case, only a module matching the supplied identifier will respond.optional 20-character NI valueNT ( v1.xA0*) Networking {Identification} Node Discover Time. Set/Read the amount of time a node will wait for responses from other nodes when using the ND (Node Discover) command.  0x01 - 0xFC 0x19DN ( v1.x80*) Networking {Identification}Destination Node. Resolves an NI (Node Identifier) string to a physical address. The following events occur upon successful command execution: 1. DL and DH are set to the address of the module with the matching Node Identifier. 2. “OK” is returned. 3. RF module automatically exits AT Command ModeIf there is no response from a module within 200 msec or a parameter is not specified (left blank), the command is terminated and an “ERROR” message is returned. 20-character ASCII string -CE ( v1.x80*) Networking {Association} Coordinator Enable. Set/Read the coordinator setting. 0 - 10 = End Device 1 = Coordinator 0SC ( v1.x80*) Networking {Association}Scan Channels. Set/Read list of channels to scan for all Active and Energy Scans as a bitfield. This affects scans initiated in command mode (AS, ED) and during End Device Association and Coordinator startup: bit 0 - 0x0B  bit 4 - 0x0F bit 8 - 0x13 bit12 - 0x17  bit 1 - 0x0C  bit 5 - 0x10 bit 9 - 0x14 bit13 - 0x18 bit 2 - 0x0D  bit 6 - 0x11 bit 10 - 0x15 bit14 - 0x19 bit 3 - 0x0E  bit 7 - 0x12 bit 11 - 0x16 bit 15 - 0x1A0 - 0xFFFF [bitfield] (bits 0, 14, 15 not allowed on the XBee-PRO)0x1FFE(all XBee-PRO Channels)SD ( v1.x80*) Networking {Association}Scan Duration. Set/Read the scan duration exponent. End Device - Duration of Active Scan during Association. On beacon system, set SD = BE of coordinator. SD must be set at least to the highest BE parameter of any Beaconing Coordinator with which an End Device or Coordinator wish to discover. Coordinator - If ‘ReassignPANID’ option is set on Coordinator [refer to A2 parameter], SD determines the length of time the Coordinator will scan channels to locate existing PANs. If ‘ReassignChannel’ option is set, SD determines how long the Coordinator will perform an Energy Scan to determine which channel it will operate on.‘Scan Time’ is measured as (# of channels to scan] * (2 ^ SD) * 15.36ms). The number of channels to scan is set by the SC command. The XBee can scan up to 16 channels (SC = 0xFFFF). The XBee PRO can scan up to 13 channels (SC = 0x3FFE).Example: The values below show results for a 13 channel scan: If SD = 0, time = 0.18 sec SD = 8, time = 47.19 sec SD = 2, time = 0.74 sec   SD = 10, time = 3.15 min SD = 4, time = 2.95 sec SD = 12, time = 12.58 min SD = 6, time = 11.80 sec SD = 14, time = 50.33 min0-0x0F [exponent] 4A1 ( v1.x80*) Networking {Association}End Device Association. Set/Read End Device association options.  bit 0 - ReassignPanID 0 - Will only associate with Coordinator operating on PAN ID that matches module ID 1 - May associate with Coordinator operating on any PAN ID bit 1 - ReassignChannel 0 - Will only associate with Coordinator operating on matching CH Channel setting 1 - May associate with Coordinator operating on any Channelbit 2 - AutoAssociate 0 - Device will not attempt Association 1 - Device attempts Association until success Note: This bit is used only for Non-Beacon systems. End Devices in Beacon-enabled system must always associate to a Coordinatorbit 3 - PollCoordOnPinWake 0 - Pin Wake will not poll the Coordinator for indirect (pending) data  1 - Pin Wake will send Poll Request to Coordinator to extract any pending databits 4 - 7 are reserved0 - 0x0F [bitfield] 0Table3‐02. XBee/XBee‐PROCommands‐Networking&Security(Sub‐categoriesdesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range Default
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 28Chapter3‐RFModuleConfigurationA2 ( v1.x80*) Networking {Association}Coordinator Association. Set/Read Coordinator association options. bit 0 - ReassignPanID 0 - Coordinator will not perform Active Scan to locate available PAN ID. It will operate        on ID (PAN ID). 1 - Coordinator will perform Active Scan to determine an available ID (PAN ID). If a    PAN ID conflict is found, the ID parameter will change. bit 1 - ReassignChannel - 0 - Coordinator will not perform Energy Scan to determine free channel. It will operate       on the channel determined by the CH parameter.  1 - Coordinator will perform Energy Scan to find a free channel, then operate on that        channel. bit 2 - AllowAssociation - 0 - Coordinator will not allow any devices to associate to it.  1 - Coordinator will allow devices to associate to it. bits 3 - 7 are reserved 0 - 7 [bitfield] 0AI ( v1.x80*) Networking {Association}Association Indication. Read errors with the last association request:0x00 - Successful Completion - Coordinator successfully started or End Device         association complete 0x01 - Active Scan Timeout  0x02 - Active Scan found no PANs  0x03 - Active Scan found PAN, but the CoordinatorAllowAssociation bit is not set 0x04 - Active Scan found PAN, but Coordinator and End Device are not           configured to support beacons  0x05 - Active Scan found PAN, but the Coordinator ID parameter does not match         the ID parameter of the End Device 0x06 - Active Scan found PAN, but the Coordinator CH parameter does not match the         CH parameter of the End Device 0x07 - Energy Scan Timeout 0x08 - Coordinator start request failed 0x09 - Coordinator could not start due to invalid parameter 0x0A - Coordinator Realignment is in progress 0x0B - Association Request not sent 0x0C - Association Request timed out - no reply was received 0x0D - Association Request had an Invalid Parameter 0x0E - Association Request Channel Access Failure. Request was not transmitted -          CCA failure 0x0F - Remote Coordinator did not send an ACK after Association Request was sent 0x10 - Remote Coordinator did not reply to the Association Request, but an ACK was         received after sending the request 0x11 - [reserved] 0x12 - Sync-Loss - Lost synchronization with a Beaconing Coordinator 0x13  - Disassociated - No longer associated to Coordinator0 - 0x13 [read-only] -DA ( v1.x80*) Networking {Association} Force Disassociation. End Device will immediately disassociate from a Coordinator (if associated) and reattempt to associate. --FP ( v1.x80*) Networking {Association} Force Poll. Request indirect messages being held by a coordinator. - -Table3‐02. XBee/XBee‐PROCommands‐Networking&Security(Sub‐categoriesdesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range Default
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 29Chapter3‐RFModuleConfiguration*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)RF Interfacing *Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)AS ( v1.x80*) Networking {Association}Active Scan. Send Beacon Request to Broadcast Address (0xFFFF) and Broadcast PAN (0xFFFF) on every channel. The parameter determines the time the radio will listen for Beacons on each channel. A PanDescriptor is created and returned for every Beacon received from the scan. Each PanDescriptor contains the following information:CoordAddress (SH, SL)<CR>  CoordPanID (ID)<CR> CoordAddrMode <CR> 0x02 = 16-bit Short Address  0x03 = 64-bit Long Address  Channel (CH parameter) <CR>  SecurityUse<CR>  ACLEntry<CR>  SecurityFailure<CR>  SuperFrameSpec<CR> (2 bytes): bit 15 - Association Permitted (MSB)  bit 14 - PAN Coordinator  bit 13 - Reserved  bit 12 - Battery Life Extension bits 8-11 - Final CAP Slot  bits 4-7 - Superframe Order  bits 0-3 - Beacon Order  GtsPermit<CR>  RSSI<CR> (RSSI is returned as -dBm) TimeStamp<CR> (3 bytes)  <CR> A carriage return <CR> is sent at the end of the AS command. The Active Scan is capable of returning up to 5 PanDescriptors in a scan. The actual scan time on each channel is measured as Time = [(2 ^SD PARAM) * 15.36] ms. Note the total scan time is this time multiplied by the number of channels to be scanned (16 for the XBee and 13 for the XBee-PRO). Also refer to SD command description. 0 - 6 -ED ( v1.x80*) Networking {Association}Energy Scan. Send an Energy Detect Scan. This parameter determines the length of scan on each channel. The maximal energy on each channel is returned & each value is followed by a carriage return. An additional carriage return is sent at the end of the command. The values returned represent the detected energy level in units of -dBm. The actual scan time on each channel is measured as Time = [(2 ^ED) * 15.36] ms. Note the total scan time is this time multiplied by the number of channels to be scanned (refer to SD parameter).0 - 6 -EE ( v1.xA0*) Networking {Security} AES Encryption Enable. Disable/Enable 128-bit AES encryption support. Use in conjunction with the KY command. 0 - 1 0 (disabled)KY ( v1.xA0*) Networking {Security} AES Encryption Key. Set the 128-bit AES (Advanced Encryption Standard) key for encrypting/decrypting data. The KY register cannot be read. 0 - (any 16-Byte value) -Table3‐03. XBee/XBee‐PROCommands‐RFInterfacingAT Command Command Category Name and Description Parameter Range DefaultPL RF InterfacingPower Level. Select/Read the power level at which the RF module transmits conducted power.NOTE: XBee-PRO RF Modules optimized for use in Japan contain firmware that limits transmit power output to 10 dBm. If PL=4 (default), the maximum power output level is fixed at 10 dBm.0 - 4 (XBee / XBee-PRO) 0 = -10 / 10 dBm 1 = -6 / 12 dBm 2 = -4 / 14 dBm 3 =  -2 / 16 dBm 4 = 0 / 18 dBm4CA (v1.x80*) RF Interfacing CCA Threshold. Set/read the CCA (Clear Channel Assessment) threshold. Prior to transmitting a packet, a CCA is performed to detect energy on the channel. If the detected energy is above the CCA Threshold, the module will not transmit the packet. 0 - 0x50 [-dBm] 0x2C(-44d dBm)Table3‐02. XBee/XBee‐PROCommands‐Networking&Security(Sub‐categoriesdesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range Default
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 30Chapter3‐RFModuleConfigurationSleep (Low Power)*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)Serial InterfacingTable3‐04. XBee/XBee‐PROCommands‐Sleep(LowPower)AT Command Command Category Name and Description Parameter Range DefaultSM Sleep (Low Power) Sleep Mode. <NonBeacon firmware> Set/Read Sleep Mode configurations.0 - 5 0 = No Sleep 1 = Pin Hibernate 2 = Pin Doze 3 = Reserved 4 = Cyclic sleep remote 5 = Cyclic sleep remote         w/ pin wake-up6 = [Sleep Coordinator] for     backwards compatibility     w/ v1.x6 only; otherwise,    use CE command.0ST Sleep (Low Power)Time before Sleep. <NonBeacon firmware> Set/Read time period of inactivity (no serial or RF data is sent or received) before activating Sleep Mode. ST parameter is only valid with Cyclic Sleep settings (SM = 4 - 5).Coordinator and End Device ST values must be equal. Also note, the GT parameter value must always be less than the ST value. (If GT > ST, the configuration will render the module unable to enter into command mode.) If the ST parameter is modified, also modify the GT parameter accordingly.1 - 0xFFFF [x 1 ms] 0x1388 (5000d)SP Sleep (Low Power)Cyclic Sleep Period. <NonBeacon firmware> Set/Read sleep period for cyclic sleeping remotes. Coordinator and End Device SP values should always be equal. To send Direct Messages, set SP = 0.End Device - SP determines the sleep period for cyclic sleeping remotes. Maximum sleep period is 268 seconds (0x68B0).Coordinator - If non-zero, SP determines the time to hold an indirect message before discarding it. A Coordinator will discard indirect messages after a period of (2.5 * SP).0 - 0x68B0 [x 10 ms]  0DP (1.x80*) Sleep (Low Power) Disassociated Cyclic Sleep Period. <NonBeacon firmware>  End Device - Set/Read time period of sleep for cyclic sleeping remotes that are configured for Association but are not associated to a Coordinator. (i.e. If a device is configured to associate, configured as a Cyclic Sleep remote, but does not find a Coordinator, it will sleep for DP time before reattempting association.) Maximum sleep period is 268 seconds (0x68B0). DP should be > 0 for NonBeacon systems.1 - 0x68B0 [x 10 ms] 0x3E8 (1000d)Table3‐05. XBee‐PROCommands‐SerialInterfacingAT Command Command Category Name and Description Parameter Range DefaultBD Serial  InterfacingInterface Data Rate. Set/Read the serial interface data rate for communications between the RF module serial port and host. Request non-standard baud rates with values above 0x80 using a terminal window. Read the BD register to find actual baud rate achieved.0 - 7 (standard baud rates) 0 = 1200 bps 1 = 2400 2 = 4800 3 = 9600 4 = 19200 5 = 38400 6 = 57600 7 = 115200 0x80 - 0x1C200  (non-standard baud rates)3RO Serial  InterfacingPacketization Timeout. Set/Read number of character times of inter-character delay required before transmission. Set to zero to transmit characters as they arrive instead of buffering them into one RF packet. 0 - 0xFF [x character times] 3AP (v1.x80*) Serial  Interfacing API Enable. Disable/Enable API Mode.0 - 2 0 = Disabled 1 = API enabled 2 = API enabled        (w/escaped control         characters)0NB Serial Interfacing Parity. Set/Read parity settings.0 - 4 0 = 8-bit (no parity or     7-bit (any parity) 1 = 8-bit even 2 = 8-bit odd 3 = 8-bit mark 4 = 8-bit space0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 31Chapter3‐RFModuleConfiguration*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)I/O SettingsPR (v1.x80*) Serial  InterfacingPull-up Resistor Enable. Set/Read bitfield to configure internal pull-up resistor status for I/O lines Bitfield Map:  bit 0 - AD4/DIO4 (pin11)  bit 1 - AD3 / DIO3 (pin17)  bit 2 - AD2/DIO2 (pin18)  bit 3 - AD1/DIO1 (pin19)  bit 4 - AD0 / DIO0 (pin20)  bit 5 - RTS / AD6 / DIO6 (pin16)  bit 6 - DTR / SLEEP_RQ / DI8 (pin9)  bit 7 - DIN/CONFIG (pin3)Bit set to “1” specifies pull-up enabled; “0” specifies no pull-up0 - 0xFF 0xFFTable3‐06. XBee‐PROCommands‐I/OSettings(sub‐categorydesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range DefaultD8 I/O Settings DI8 Configuration. Select/Read options for the DI8 line (pin 9) of the RF module.0 - 1 0 = Disabled 3 = DI  (1,2,4 & 5 n/a)0D7 (v1.x80*) I/O Settings DIO7 Configuration. Select/Read settings for the DIO7 line (pin 12) of the RF module. Options include CTS flow control and I/O line settings.0 - 1 0 = Disabled 1 = CTS Flow Control 2 = (n/a) 3 = DI 4 = DO low 5 = DO high1D6 (v1.x80*) I/O Settings DIO6 Configuration. Select/Read settings for the DIO6 line (pin 16) of the RF module. Options include RTS flow control and I/O line settings.0 - 1 0 = Disabled  1 = RTS flow control 2 = (n/a) 3 = DI  4 = DO low  5 = DO high 0D5 (v1.x80*) I/O Settings DIO5 Configuration. Configure settings for the DIO5 line (pin 15) of the RF module. Options include Associated LED indicator (blinks when associated) and I/O line settings.0 - 1 0 = Disabled  1 = Associated indicator  2 = ADC 3 = DI 4 = DO low  5 = DO high 1D0 - D4 (v1.xA0*) I/O Settings (DIO4 -DIO4) Configuration. Select/Read settings for the following lines: AD0/DIO0 (pin 20), AD1/DIO1 (pin 19), AD2/DIO2 (pin 18), AD3/DIO3 (pin 17), AD4/DIO4 (pin 11).Options include: Analog-to-digital converter, Digital Input and Digital Output.0 - 1 0 = Disabled  1 = (n/a)  2 = ADC  3 = DI 4 = DO low  5 = DO high 0IU (v1.xA0*) I/O Settings I/O Output Enable. Disables/Enables I/O data received to be sent out UART. The data is sent using an API frame regardless of the current AP parameter value.0 - 1 0 = Disabled 1 = Enabled 1IT (v1.xA0*) I/O Settings Samples before TX. Set/Read the number of samples to collect before transmitting data. Maximum number of samples is dependent upon the number of enabled inputs. 1 - 0xFF 1IS (v1.xA0*) I/O Settings Force Sample. Force a read of all enabled inputs (DI or ADC). Data is returned through the UART. If no inputs are defined (DI or ADC), this command will return error.8-bit bitmap (each bit represents the level of an I/O line setup as an output) -IO (v1.xA0*) I/O Settings Digital Output Level. Set digital output level to allow DIO lines that are setup as outputs to be changed through Command Mode. --IC (v1.xA0*) I/O Settings DIO Change Detect. Set/Read bitfield values for change detect monitoring. Each bit enables monitoring of DIO0 - DIO7 for changes. If detected, data is transmitted with DIO data only. Any samples queued waiting for transmission will be sent first. 0 - 0xFF [bitfield] 0 (disabled)IR (v1.xA0*) I/O Settings Sample Rate. Set/Read sample rate. When set, this parameter causes the module to sample all enabled inputs at a specified interval. 0 - 0xFFFF [x 1 msec] 0AV (v1.xA0*) I/O Settings ADC Voltage Reference. <XBee-PRO only> Set/Read ADC reference voltage switch. 0 - 1 0 = VREF pin 1 = Internal 0Table3‐05. XBee‐PROCommands‐SerialInterfacingAT Command Command Category Name and Description Parameter Range Default
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 32Chapter3‐RFModuleConfiguration*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)Diagnostics*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)IA (v1.xA0*) I/O Settings {I/O Line Passing}I/O Input Address. Set/Read addresses of module to which outputs are bound. Setting all bytes to 0xFF will not allow any received I/O packet to change outputs. Setting address to 0xFFFF will allow any received I/O packet to change outputs. 0 - 0xFFFFFFFFFFFFFFFF 0xFFFFFFFFFFFFFFFFT0 - T7 (v1.xA0*) I/O Settings {I/O Line Passing}(D0 - D7) Output Timeout. Set/Read Output timeout values for lines that correspond with the D0 - D7 parameters. When output is set (due to I/O line passing) to a non-default level, a timer is started which when expired will set the output to it default level. The timer is reset when a valid I/O packet is received.0 - 0xFF [x 100 ms] 0xFFP0 I/O Settings {I/O Line Passing} PWM0 Configuration. Select/Read function for PWM0 pin.0 - 2 0 = Disabled  1 = RSSI  2 = PWM Output 1P1 (v1.xA0*) I/O Settings {I/O Line Passing} PWM1 Configuration. Select/Read function for PWM1 pin.0 - 2 0 = Disabled  1 = RSSI  2 = PWM Output 0M0 (v1.xA0*) I/O Settings {I/O Line Passing} PWM0 Output Level. Set/Read the PWM0 output level. 0 - 0x03FF  -M1 (v1.xA0*) I/O Settings {I/O Line Passing} PWM1 Output Level. Set/Read the PWM0 output level. 0 - 0x03FF -PT (v1.xA0*) I/O Settings {I/O Line Passing}PWM Output Timeout. Set/Read output timeout value for both PWM outputs. When PWM is set to a non-zero value: Due to I/O line passing, a time is started which when expired will set the PWM output to zero. The timer is reset when a valid I/O packet is received.]0 - 0xFF [x 100 ms] 0xFFRP I/O Settings {I/O Line Passing}RSSI PWM Timer. Set/Read PWM timer register. Set the duration of PWM (pulse width modulation) signal output on the RSSI pin. The signal duty cycle is updated with each received packet and is shut off when the timer expires.] 0 - 0xFF [x 100 ms] 0x28 (40d)Table3‐07. XBee/XBee‐PROCommands‐DiagnosticsAT Command Command Category Name and Description Parameter Range DefaultVR Diagnostics Firmware Version. Read firmware version of the RF module. 0 - 0xFFFF [read-only] Factory-setVL (v1.x80*) Diagnostics Firmware Version - Verbose. Read detailed version information (including application build date, MAC, PHY and bootloader versions). --HV (v1.x80*) Diagnostics Hardware Version. Read hardware version of the RF module. 0 - 0xFFFF [read-only] Factory-setDB Diagnostics Received Signal Strength. Read signal level [in dB] of last good packet received (RSSI). Absolute value is reported. (For example: 0x58 = -88 dBm) Reported value is accurate between -40 dBm and RX sensitivity.0x17-0x5C (XBee) 0x24-0x64 (XBee-PRO)  [read-only] -EC (v1.x80*) DiagnosticsCCA Failures. Reset/Read count of CCA (Clear Channel Assessment) failures. This parameter value increments when the module does not transmit a packet because it detected energy above the CCA threshold level set with CA command. This count saturates at its maximum value. Set count to “0” to reset count.0 - 0xFFFF -EA (v1.x80*) DiagnosticsACK Failures. Reset/Read count of acknowledgment failures. This parameter value increments when the module expires its transmission retries without receiving an ACK on a packet transmission. This count saturates at its maximum value. Set the parameter to “0” to reset count.0 - 0xFFFF -ED (v1.x80*) DiagnosticsEnergy Scan. Send ‘Energy Detect Scan’. ED parameter determines the length of scan on each channel. The maximal energy on each channel is returned and each value is followed by a carriage return. Values returned represent detected energy levels in units of -dBm. Actual scan time on each channel is measured as Time = [(2 ^ SD) * 15.36] ms. Total scan time is this time multiplied by the number of channels to be scanned.0 - 6 -Table3‐06. XBee‐PROCommands‐I/OSettings(sub‐categorydesignatedwithin{brackets})AT Command Command Category Name and Description Parameter Range Default
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 33Chapter3‐RFModuleConfigurationAT Command Options*Firmwareversioninwhichthecommandwasfirstintroduced(firmwareversionsarenumberedinhexadecimalnotation.)Table3‐08. XBee/XBee‐PROCommands‐ATCommandOptionsAT Command Command Category Name and Description Parameter Range DefaultCT AT Command Mode OptionsCommand Mode Timeout. Set/Read the period of inactivity (no valid commands received) after which the RF module automatically exits AT Command Mode and returns to Idle Mode. 2 - 0xFFFF [x 100 ms] 0x64 (100d)CN AT Command Mode Options Exit Command Mode. Explicitly exit the module from AT Command Mode. -- --AC (v1.xA0*) AT Command Mode Options Apply Changes. Explicitly apply changes to queued parameter value(s) and re-initialize module. -- --GT AT Command Mode OptionsGuard Times. Set required period of silence before and after the Command Sequence Characters of the AT Command Mode Sequence (GT+ CC + GT). The period of silence is used to prevent inadvertent entrance into AT Command Mode. 2 - 0x0CE4 [x 1 ms] 0x3E8 (1000d)CC AT Command Mode OptionsCommand Sequence Character. Set/Read the ASCII character value to be used between Guard Times of the AT Command Mode Sequence (GT+CC+GT). The AT Command Mode Sequence enters the RF module into AT Command Mode. 0 - 0xFF 0x2B  (‘+’ ASCII)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 34Chapter3‐RFModuleConfiguration3.3. Command DescriptionsCommand descriptions in this section are listed alphabetically. Command categories are desig-nated within "< >" symbols that follow each command title. XBee/XBee-PRO RF Modules expect parameter values in hexadecimal (designated by the "0x" prefix).All modules operating within the same network should contain the same firmware version.A1 (End Device Association) Command<Networking {Association}> The A1 command is used to set and read association options for an End Device.Use the table below to determine End Device behavior in relation to the A1 parameter.A2 (Coordinator Association) Command<Networking {Association}> The A2 command is used to set and read association options of the Coordinator.Use the table below to determine Coordinator behavior in relation to the A2 parameter.Thebinaryequivalentofthedefaultvalue(0x06)is00000110.‘Bit0’isthelastdigitofthesequence.Bit number End Device Association Option0 - ReassignPanID 0 - Will only associate with Coordinator operating on PAN ID that matches Node Identifier1 - May associate with Coordinator operating on any PAN ID1 - ReassignChannel 0 - Will only associate with Coordinator operating on Channel that matches CH setting1 - May associate with Coordinator operating on any Channel2 - AutoAssociate0 - Device will not attempt Association1 - Device attempts Association until success Note: This bit is used only for Non-Beacon systems. End Devices in a Beaconing system must always associate to a Coordinator3 -  PollCoordOnPinWake 0 - Pin Wake will not poll the Coordinator for pending (indirect) Data1 - Pin Wake will send Poll Request to Coordinator to extract any pending data4 - 7 [reserved]Bit number End Device Association Option0 - ReassignPanID0 - Coordinator will not perform Active Scan to locate available PAN ID. It will operate on ID (PAN ID). 1 - Coordinator will perform Active Scan to determine an available ID (PAN ID). If a PAN ID conflict is found, the ID parameter will change.1 - ReassignChannel0 - Coordinator will not perform Energy Scan to determine free channel. It will operate on the channel determined by the CH parameter.1 - Coordinator will perform Energy Scan to find a free channel, then operate on that channel. 2 - AllowAssociate 0 - Coordinator will not allow any devices to associate to it.1 - Coordinator will allow devices to associate to it.3 - 7 [reserved]AT Command: ATA1Parameter Range: 0 - 0x0F [bitfield]Default Parameter Value: 0Related Commands: ID (PAN ID), NI (Node Identifier), CH (Channel), CE (Coordinator Enable), A2 (Coordinator Association)Minimum Firmware Version Required: v1.x80AT Command: ATA2Parameter Range: 0 - 7 [bitfield]Default Parameter Value: 0Related Commands: ID (PAN ID), NI (Node Identifier), CH (Channel), CE (Coordinator Enable), A1 (End Device Association), AS Active Scan), ED (Energy Scan)Minimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 35Chapter3‐RFModuleConfigurationAC (Apply Changes) Command<AT Command Mode Options> The AC command is used to explicitly apply changes to module parameter values. ‘Applying changes’ means that the module is re-initialized based on changes made to its parameter values. Once changes are applied, the module immediately operates according to the new parameter values.This behavior is in contrast to issuing the WR (Write) command. The WR command saves parame-ter values to non-volatile memory, but the module still operates according to previously saved val-ues until the module is re-booted or the CN (Exit AT Command Mode) command is issued.Refer to the “AT Command - Queue Parameter Value” API type for more information.AI (Association Indication) Command<Networking {Association}> The AI command is used to indicate occurrences of errors during the last association request.Use the table below to determine meaning of the returned values.Returned Value (Hex) Association Indication0x00 Successful Completion - Coordinator successfully started or End Device association complete0x01 Active Scan Timeout0x02 Active Scan found no PANs0x03 Active Scan found PAN, but the Coordinator Allow Association bit is not set0x04 Active Scan found PAN, but Coordinator and End Device are not configured to support beacons0x05 Active Scan found PAN, but Coordinator ID (PAN ID) value does not match the ID of the End Device0x06 Active Scan found PAN, but Coordinator CH (Channel) value does not match the CH of the End Device0x07 Energy Scan Timeout0x08 Coordinator start request failed0x09 Coordinator could not start due to Invalid Parameter0x0A Coordinator Realignment is in progress0x0B Association Request not sent0x0C Association Request timed out - no reply was received0x0D Association Request had an Invalid Parameter0x0E Association Request Channel Access Failure - Request was not transmitted - CCA failure0x0F Remote Coordinator did not send an ACK after Association Request was sent0x10 Remote Coordinator did not reply to the Association Request, but an ACK was received  after sending the request0x11 [reserved]0x12 Sync-Loss - Lost synchronization with a Beaconing Coordinator0x13 Disassociated - No longer associated to Coordinator0xFF RF Module is attempting to associateAT Command: ATACMinimum Firmware Version Required: v1.xA0AT Command: ATAIParameter Range: 0 - 0x13 [read-only]Related Commands: AS (Active Scan), ID (PAN ID), CH (Channel), ED (Energy Scan), A1 (End Device Association), A2 (Coordinator Association), CE (Coordinator Enable)Minimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 36Chapter3‐RFModuleConfigurationAP (API Enable) Command<Serial Interfacing> The AP command is used to enable the RF module to operate using a frame-based API instead of using the default Transpar-ent (UART) mode.Refer to the API Operation section when API operation is enabled (AP = 1 or 2).AS (Active Scan) Command<AT Command Mode Options> The AS command is used to send a Beacon Request to a Broadcast  (0xFFFF) and Broadcast PAN (0xFFFF) on every channel. The parameter determines the amount of time the RF module will listen for Beacons on each channel. A ‘PanDescriptor’ is created and returned for every Beacon received from the scan. Each PanDescriptor contains the following information:CoordAddress (SH + SL parameters)<CR> (NOTE: If MY on the coordinator is set less than 0xFFFF, the MY value is displayed) CoordPanID (ID parameter)<CR> CoordAddrMode <CR> 0x02 = 16-bit Short Address  0x03 = 64-bit Long Address  Channel (CH parameter) <CR>  SecurityUse<CR>  ACLEntry<CR>  SecurityFailure<CR>  SuperFrameSpec<CR> (2 bytes): bit 15 - Association Permitted (MSB)  bit 14 - PAN Coordinator  bit 13 - Reserved  bit 12 - Battery Life Extension bits 8-11 - Final CAP Slot  bits 4-7 - Superframe Order  bits 0-3 - Beacon Order  GtsPermit<CR>  RSSI<CR> (- RSSI is returned as -dBm)  TimeStamp<CR> (3 bytes)  <CR> (A carriage return <CR> is sent at the end of the AS command.The Active Scan is capable of returning up to 5 PanDescriptors in a scan. The actual scan time on each channel is measured as Time = [(2 ^ (SD Parameter)) * 15.36] ms. Total scan time is this time multiplied by the number of channels to be scanned (16 for the XBee, 12 for the XBee-PRO).NOTE: Refer the scan table in the SD description to determine scan times. If using API Mode, no <CR>’s are returned in the response. Refer to the API Mode Operation section.AT Command: ATAPParameter Range:0 - 2Parameter Configuration0Disabled(Transparent operation)1 API enabled2API enabled (with escaped characters)Default Parameter Value:0Minimum Firmware Version Required: v1.x80AT Command: ATASParameter Range: 0 - 6Related Command: SD (Scan Duration), DL (Destination Low Address), DH (Destination High Address), ID (PAN ID), CH (Channel)Minimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 37Chapter3‐RFModuleConfigurationAV (ADC Voltage Reference) Command<Serial Interfacing> The AV command is used to set/read the ADC reference voltage switch. The XBee-PRO has an ADC voltage reference switch which allows the module to select between an on-board voltage reference or to use the VREF pin on the connector. This command only applies to XBee-PRO RF Mod-ules and will return error on an XBee RF Module.BD (Interface Data Rate) Command<Serial Interfacing> The BD command is used to set and read the serial interface data rate used between the RF module and host. This parameter determines the rate at which serial data is sent to the module from the host. Modified interface data rates do not take effect until the CN (Exit AT Com-mand Mode) command is issued and the system returns the 'OK' response.When parameters 0-7 are sent to the module, the respective interface data rates are used (as shown in the table on the right).The RF data rate is not affected by the BD param-eter. If the interface data rate is set higher than the RF data rate, a flow control configuration may need to be implemented.Non-standard Interface Data Rates:  Any value above 0x07 will be interpreted as an actual baud rate. When a value above 0x07 is sent, the closest interface data rate represented by the number is stored in the BD register. For example, a rate of 19200 bps can be set by sending the following command line "ATBD4B00". NOTE: When using MaxStream’s X-CTU Software, non-standard interface data rates can only be set and read using the X-CTU ‘Terminal’ tab. Non-stan-dard rates are not accessible through the ‘Modem Configuration’ tab.When the BD command is sent with a non-standard interface data rate, the UART will adjust to accommodate the requested interface rate. In most cases, the clock resolution will cause the stored BD parameter to vary from the parameter that was sent (refer to the table below). Reading the BD command (send "ATBD" command without an associated parameter value) will return the value actually stored in the module’s BD register.CA (CCA Threshold) Command<RF Interfacing> CA command is used to set and read CCA (Clear Channel Assessment) thresholds.Prior to transmitting a packet, a CCA is performed to detect energy on the transmit channel. If the detected energy is above the CCA Threshold, the RF module will not transmit the packet.ParametersSentVer s u sParametersStoredBD Parameter Sent (HEX) Interface Data Rate (bps) BD Parameter Stored (HEX)0 1200 04 19,200 47 115,200 712C 300 12B1C200 115,200 1B207AT Command: ATAVParameter Range:0 - 1Parameter Configuration0VREF Pin1Internal (on-board reference - VCC)Default Parameter Value:0Minimum Firmware Version Required: v1.xA0AT Command: ATBDParameter Range:0 - 7 (standard rates) 0x80-0x1C200 (non-stndard rates)Parameter Configuration (bps)012001240024800396004 192005 384006 576007 115200Default Parameter Value:3AT Command: ATCAParameter Range: 0 - 0x50 [-dBm]Default Parameter Value: 0x2C             (-44 decimal dBm)Minimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 38Chapter3‐RFModuleConfigurationCC (Command Sequence Character) Command<AT Command Mode Options> The CC command is used to set and read the ASCII character used between guard times of the AT Command Mode Sequence (GT + CC + GT). This sequence enters the RF module into AT Command Mode so that data entering the module from the host is recog-nized as commands instead of payload.The AT Command Sequence is explained further in the AT Command Mode section.CE (Coordinator Enable) Command<Serial Interfacing> The CE command is used to set and read the behavior (End Device vs. Coordi-nator) of the RF module.CH (Channel) Command<Networking {Addressing}> The CH command is used to set/read the operating channel on which RF connections are made between RF modules. The channel is one of three addressing options available to the module. The other options are the PAN ID (ID command) and destination addresses (DL & DH commands).In order for modules to communicate with each other, the modules must share the same channel number. Different channels can be used to prevent modules in one network from listening to trans-missions of another. Adjacent channel rejection is 23 dB.The module uses channel numbers of the 802.15.4 standard. Center Frequency = 2.405 + (CH - 11d) * 5 MHz (d = decimal)Refer to the XBee/XBee-PRO Addressing section for more information.CN (Exit Command Mode) Command<AT Command Mode Options> The CN command is used to explicitly exit the RF module from AT Command Mode.CT (Command Mode Timeout) Command<AT Command Mode Options> The CT command is used to set and read the amount of inactive time that elapses before the RF module automati-cally exits from AT Command Mode and returns to Idle Mode.Use the CN (Exit Command Mode) command to exit AT Command Mode manually.AT Command: ATCCParameter Range: 0 - 0xFFDefault Parameter Value: 0x2B (ASCII “+”)Related Command: GT (Guard Times)AT Command: ATCEParameter Range:0 - 1Parameter Configuration0End Device1 CoordinatorDefault Parameter Value:0Minimum Firmware Version Required: v1.x80AT Command: ATCHParameter Range: 0x0B - 0x1A (XBee)  0x0C - 0x17 (XBee-PRO)Default Parameter Value: 0x0C (12 decimal)Related Commands: ID (PAN ID), DL (Destination Address Low, DH (Destination Address High)AT Command: ATCNAT Command: ATCTParameter Range:2 - 0xFFFF [x 100 milliseconds]Default Parameter Value: 0x64 (100 decimal (which equals 10 decimal seconds))Number of bytes returned: 2Related Command: CN (Exit Command Mode)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 39Chapter3‐RFModuleConfigurationD0 - D4 (DIOn Configuration) Commands<I/O Settings> The D0, D1, D2, D3 and D4 com-mands are used to select/read the behavior of their respective AD/DIO lines (pins 20, 19, 18, 17 and 11 respectively). Options include: • Analog-to-digital converter• Digital input •Digital outputD5 (DIO5 Configuration) Command<I/O Settings> The D5 command is used to select/read the behavior of the DIO5 line (pin 15).Options include: • Associated Indicator (LED blinks when the module is associated)• Analog-to-digital converter• Digital input •Digital outputD6 (DIO6 Configuration) Command<I/O Settings> The D6 command is used to select/read the behavior of the DIO6 line (pin 16). Options include: • RTS flow control• Analog-to-digital converter• Digital input •Digital outputAT Commands:  ATD0, ATD1, ATD2, ATD3, ATD4Parameter Range:0 - 5Parameter Configuration0 Disabled1n/a2ADC3DI4DO low5DO highDefault Parameter Value:0Minimum Firmware Version Required: 1.x.A0AT Command: ATD5Parameter Range:0 - 5Parameter Configuration0 Disabled1 Associated Indicator2ADC3DI4DO low5DO highDefault Parameter Value:1Parameters 2-5 supported as of firmware version 1.xA0AT Command: ATD6Parameter Range:0 - 5Parameter Configuration0 Disabled1RTS Flow Control2n/a3DI4DO low5DO highDefault Parameter Value:0Parameters 3-5 supported as of firmware version 1.xA0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 40Chapter3‐RFModuleConfigurationD7 (DIO7 Configuration) Command<I/O Settings> The D7 command is used to select/read the behavior of the DIO7 line (pin 12). Options include: • CTS flow control• Analog-to-digital converter• Digital input •Digital outputD8 (DI8 Configuration) Command<I/O Settings> The D8 command is used to select/read the behavior of the DI8 line (pin 9). This command enables configuring the pin to function as a digital input. This line is also used with Pin Sleep.DA (Force Disassociation) Command<(Special)> The DA command is used to immedi-ately disassociate an End Device from a Coordi-nator and reattempt to associate.DB (Received Signal Strength) Command<Diagnostics> DB parameter is used to read the received signal strength (in dBm) of the last RF packet received. Reported values are accurate between -40 dBm and the RF module's receiver sensitivity.Absolute values are reported. For example: 0x58 = -88 dBm (decimal). If no packets have been received (since last reset, power cycle or sleep event), “0” will be reported.DH (Destination Address High) Command<Networking {Addressing}> The DH command is used to set and read the upper 32 bits of the RF module's 64-bit destination address. When com-bined with the DL (Destination Address Low) parameter, it defines the destination address used for transmission.An module will only communicate with other modules having the same channel (CH parame-ter), PAN ID (ID parameter) and destination address (DH + DL parameters).To transmit using a 16-bit address, set the DH parameter to zero and the DL parameter less than 0xFFFF. 0x000000000000FFFF (DL concatenated to DH) is the broadcast address for the PAN.Refer to the XBee/XBee-PRO Addressing section for more information.AT Command: ATD7Parameter Range:0 - 5Parameter Configuration0 Disabled1CTS Flow Control2n/a3DI4DO low5DO highDefault Parameter Value:1Parameters 3-5 supported as of firmware version 1.x.A0AT Command: ATD8Parameter Range:0 - 5  (1, 2, 4 & 5 n/a)Parameter Configuration0 Disabled3DIDefault Parameter Value:0Minimum Firmware Version Required: 1.xA0AT Command: ATDAMinimum Firmware Version Required: v1.x80AT Command: ATDBParameter Range [read-only]:  0x17-0x5C (XBee), 0x24-0x64 (XBee-PRO)AT Command: ATDHParameter Range: 0 - 0xFFFFFFFFDefault Parameter Value: 0Related Commands: DL (Destination Address Low), CH (Channel), ID (PAN VID), MY (Source Address)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 41Chapter3‐RFModuleConfigurationDL (Destination Address Low) Command<Networking {Addressing}> The DL command is used to set and read the lower 32 bits of the RF module's 64-bit destination address. When com-bined with the DH (Destination Address High) parameter, it defines the destination address used for transmission.A module will only communicate with other mod-ules having the same channel (CH parameter), PAN ID (ID parameter) and destination address (DH + DL parameters).To transmit using a 16-bit address, set the DH parameter to zero and the DL parameter less than 0xFFFF. 0x000000000000FFFF (DL concatenated to DH) is the broadcast address for the PAN.Refer to the XBee/XBee-PRO Addressing section for more information.DN (Destination Node) Command<Networking {Identification}> The DN command is used to resolve a NI (Node Identifier) string to a physical address. The following events occur upon successful command execution:1. DL and DH are set to the address of the module with the matching NI (Node Identifier). 2. ‘OK’ is returned. 3. RF module automatically exits AT Command Mode.If there is no response from a modem within 200 msec or a parameter is not specified (left blank), the command is terminated and an ‘ERROR’ message is returned.DP (Disassociation Cyclic Sleep Period) Command<Sleep Mode (Low Power)>NonBeacon FirmwareEnd Device - The DP command is used to set and read the time period of sleep for cyclic sleeping remotes that are configured for Association but are not associated to a Coordinator. (i.e. If a device is configured to associate, configured as a Cyclic Sleep remote, but does not find a Coordi-nator; it will sleep for DP time before reattempt-ing association.) Maximum sleep period is 268 seconds (0x68B0). DP should be > 0 for NonBeacon systems.EA (ACK Failures) Command<Diagnostics> The EA command is used to reset and read the count of ACK (acknowledgement) failures. This parameter value increments when the module expires its transmission retries with-out receiving an ACK on a packet transmission. This count saturates at its maximum value. Set the parameter to “0” to reset count.AT Command: ATDLParameter Range: 0 - 0xFFFFFFFFDefault Parameter Value: 0Related Commands: DH (Destination Address High), CH (Channel), ID (PAN VID), MY (Source Address)AT Command: ATDNParameter Range: 20-character ASCII StringMinimum Firmware Version Required: v1.x80AT Command: ATDPParameter Range: 1 - 0x68B0   [x 10 milliseconds]Default Parameter Value:0x3E8 (1000 decimal)Related Commands: SM (Sleep Mode), SP (Cyclic Sleep Period), ST (Time before Sleep)Minimum Firmware Version Required: v1.x80AT Command: ATEAParameter Range:0 - 0xFFFFMinimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 42Chapter3‐RFModuleConfigurationEC (CCA Failures) Command<Diagnostics> The EC command is used to read and reset the count of CCA (Clear Channel Assessment) failures. This parameter value incre-ments when the RF module does not transmit a packet due to the detection of energy that is above the CCA threshold level (set with CA com-mand). This count saturates at its maximum value. Set the EC parameter to “0” to reset count.ED (Energy Scan) Command<Networking {Association}> The ED command is used to send an “Energy Detect Scan”. This parameter determines the length of scan on each channel. The maximal energy on each channel is returned and each value is followed by a carriage return. An additional carriage return is sent at the end of the command. The values returned represent the detected energy level in units of -dBm. The actual scan time on each channel is measured as Time = [(2 ^ ED PARAM) * 15.36] ms.Note: Total scan time is this time multiplied by the number of channels to be scanned. Also refer to the SD (Scan Duration) table. Use the SC (Scan Channel) command to choose which channels to scan.EE (AES Encryption Enable) Command<Networking {Security}> The EE command is used to set/read the parameter that disables/enables 128-bit AES encryption.The XBee/XBee-PRO firmware uses the 802.15.4 Default Security protocol and uses AES encryption with a 128-bit key. AES encryption dictates that all modules in the network use the same key and the maximum RF packet size is 95 Bytes.When encryption is enabled, the module will always use its 64-bit long address as the source address for RF packets. This does not affect how the MY (Source Address), DH (Destination Address High) and DL (Destination Address Low) parameters workIf MM (MAC Mode) > 0 and AP (API Enable) parameter > 0:  With encryption enabled and a 16-bit short address set, receiving modules will only be able to issue RX (Receive) 64-bit indicators. This is not an issue when MM = 0.If a module with a non-matching key detects RF data, but has an incorrect key: When encryption is enabled, non-encrypted RF packets received will be rejected and will not be sent out the UART.Transparent Operation --> All RF packets are sent encrypted if the key is set.API Operation --> Receive frames use an option bit to indicate that the packet was encrypted.FP (Force Poll) Command<Networking (Association)> The FP command is used to request indirect messages being held by a Coordinator.AT Command: ATECParameter Range:0 - 0xFFFFRelated Command: CA (CCA Threshold)Minimum Firmware Version Required: v1.x80AT Command: ATEDParameter Range:0 - 6Related Command: SD (Scan Duration), SC (Scan Channel)Minimum Firmware Version Required: v1.x80AT Command: ATEEParameter Range:0 - 1Parameter Configuration0 Disabled1EnabledDefault Parameter Value:0Related Commands: KY (Encryption Key), AP (API Enable), MM (MAC Mode)Minimum Firmware Version Required: v1.xA0AT Command: ATFPMinimum Firmware Version Required: v1.x80
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 43Chapter3‐RFModuleConfigurationFR (Software Reset) Command<Special> The FR command is used to force a software reset on the RF module. The reset simu-lates powering off and then on again the module.GT (Guard Times) Command<AT Command Mode Options> GT Command is used to set the DI (data in from host) time-of-silence that surrounds the AT command sequence character (CC Command) of the AT Command Mode sequence (GT + CC + GT). The DI time-of-silence is used to prevent inad-vertent entrance into AT Command Mode.Refer to the Command Mode section for more information regarding the AT Command Mode Sequence.HV (Hardware Version) Command<Diagnostics> The HV command is used to read the hardware version of the RF module.IA (I/O Input Address) Command<I/O Settings {I/O Line Passing}> The IA com-mand is used to bind a module output to a spe-cific address. Outputs will only change if received from this address. The IA command can be used to set/read both 16 and 64-bit addresses.Setting all bytes to 0xFF will not allow the recep-tion of any I/O packet to change outputs. Setting the IA address to 0xFFFF will cause the module to accept all I/O packets.IC (DIO Change Detect) Command<I/O Settings> Set/Read bitfield values for change detect monitoring. Each bit enables moni-toring of DIO0 - DIO7 for changes. If detected, data is transmitted with DIO data only. Any samples queued waiting for transmis-sion will be sent first.Refer to the “ADC and Digital I/O Line Support” sections of the “RF Module Operations” chapter for more information.ID (Pan ID) Command<Networking {Addressing}> The ID command is used to set and read the PAN (Personal Area Net-work) ID of the RF module. Only modules with matching PAN IDs can communicate with each other. Unique PAN IDs enable control of which RF packets are received by a module.Setting the ID parameter to 0xFFFF indicates a global transmission for all PANs. It does not indi-cate a global receive.AT Command: ATFRMinimum Firmware Version Required: v1.x80AT Command: ATGTParameter Range:2 - 0x0CE4 [x 1 millisecond]Default Parameter Value:0x3E8  (1000 decimal)Related Command: CC (Command Sequence Character)AT Command: ATHVParameter Range:0 - 0xFFFF [Read-only]Minimum Firmware Version Required: v1.x80AT Command: ATIAParameter Range:0 - 0xFFFFFFFFFFFFFFFFDefault Parameter Value:0xFFFFFFFFFFFFFFFF (will not allow any received I/O packet to change outputs)Minimum Firmware Version Required: v1.xA0AT Command: ATICParameter Range:0 - 0xFF [bitfield]Default Parameter Value:0 (disabled)Minimum Firmware Version Required: 1.xA0AT Command: ATIDParameter Range: 0 - 0xFFFFDefault Parameter Value:0x3332(13106 decimal)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 44Chapter3‐RFModuleConfigurationIO (Digital Output Level) Command<I/O Settings> The IO command is used to set digital output levels. This allows DIO lines setup as outputs to be changed through Command Mode.IR (Sample Rate) Command<I/O Settings> The IR command is used to set/read the sample rate. When set, the module will sample all enabled DIO/ADC lines at a specified interval. This command allows periodic reads of the ADC and DIO lines in a non-Sleep Mode setup.Example: When IR = 0x0A, the sample rate is 10 ms (or 100 Hz).IS (Force Sample) Command<I/O Settings> The IS command is used to force a read of all enabled DIO/ADC lines. The data is returned through the UART.When operating in Transparent Mode (AP=0), the data is retuned in the following format:All bytes are converted to ASCII:      number of samples<CR>      channel mask<CR>      DIO data<CR> (If DIO lines are enabled<CR>      ADC channel Data<cr> <-This will repeat for every enabled ADC channel<CR>      <CR>  (end of data noted by extra <CR>)When operating in API mode (AP > 0), the command will immediately return an ‘OK’ response. The data will follow in the normal API format for DIO data.IT (Samples before TX) Command<I/O Settings> The IT command is used to set/read the number of DIO and ADC samples to col-lect before transmitting data. One ADC sample is considered complete when all enabled ADC channels have been read. The mod-ule can buffer up to 93 Bytes of sample data. Since the module uses a 10-bit A/D converter, each sample uses two Bytes. This leads to a maxi-mum buffer size of 46 samples or IT=0x2E.When Sleep Modes are enabled and IR (Sample Rate) is set, the module will remain awake until IT samples have been collected.AT Command: ATIOParameter Range: 8-bit bitmap  (where each bit represents the level of an I/O line that is setup as an output.)Minimum Firmware Version Required: v1.xA0AT Command: ATIRParameter Range: 0 - 0xFFFF [x 1 msec] (cannot guarantee 1 ms timing when IT=1)Default Parameter Value:0Related Command: IT (Samples before TX)Minimum Firmware Version Required: v1.xA0AT Command: ATISParameter Range: 1 - 0xFFDefault Parameter Value:1Minimum Firmware Version Required: v1.xA0AT Command: ATITParameter Range: 1 - 0xFFDefault Parameter Value:1Minimum Firmware Version Required: v1.xA0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 45Chapter3‐RFModuleConfigurationIU (I/O Output Enable) Command<I/O Settings> The IU command is used to dis-able/enable I/O UART output. When enabled (IU = 1), received I/O line data packets are sent out the UART. The data is sent using an API frame regardless of the current AP parameter value.KY (AES Encryption Key) Command<Networking {Security}> The KY command is used to set the 128-bit AES (Advanced Encryption Standard) key for encrypting/decrypting data. Once set, the key cannot be read out of the mod-ule by any means. The entire payload of the packet is encrypted using the key and the CRC is computed across the ciphertext. When encryption is enabled, each packet carries an additional 16 Bytes to convey the random CBC Initialization Vector (IV) to the receiver(s). The KY value may be “0” or any 128-bit value. Any other value, including entering KY by itself with no parameters, is invalid. All ATKY entries (valid or not) are received with a returned 'OK'.A module with the wrong key (or no key) will receive encrypted data, but the data driven out the serial port will be meaningless. A module with a key and encryption enabled will receive data sent from a module without a key and the correct unencrypted data output will be sent out the serial port. Because CBC mode is utilized, repetitive data appears differently in different transmissions due to the randomly-generated IV.When queried, the system will return an ‘OK’ message and the value of the key will not be returned.M0 (PWM0 Output Level) Command<I/O Settings> The M0 command is used to set/read the output level of the PWM0 line (pin 6).Before setting the line as an output: 1. Enable PWM0 output (P0 = 2)  2. Apply settings (use CN or AC)The PWM period is 64 µsec and there are 0x03FF (1023 decimal) steps within this period. When M0 = 0 (0% PWM), 0x01FF (50% PWM), 0x03FF (100% PWM), etc.M1 (PWM1 Output Level) Command<I/O Settings> The M1 command is used to set/read the output level of the PWM1 line (pin 7).Before setting the line as an output: 1. Enable PWM1 output (P1 = 2)  2. Apply settings (use CN or AC)AT Command: ATIUParameter Range:0 - 1Parameter Configuration0Disabled - Received I/O line data packets will NOT sent out UART.1Enabled -Received I/O line data will be sent out UARTDefault Parameter Value:1Minimum Firmware Version Required: 1.xA0AT Command: ATKYParameter Range:0 - (any 16-Byte value)Default Parameter Value:0Related Command: EE (Encryption Enable)Minimum Firmware Version Required: v1.xA0AT Command: ATM0Parameter Range:0 - 0x03FF [steps]Default Parameter Value:0Related Commands: P0 (PWM0 Enable), AC (Apply Changes), CN (Exit Command Mode)Minimum Firmware Version Required: v1.xA0AT Command: ATM1Parameter Range:0 - 0x03FFDefault Parameter Value:0Related Commands: P1 (PWM1 Enable), AC (Apply Changes), CN (Exit Command Mode)Minimum Firmware Version Required: v1.xA0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 46Chapter3‐RFModuleConfigurationMM (MAC Mode) Command<Networking {Addressing}> The MM command is used to set and read the MAC Mode value. The MM command disables/enables the use of a Max-Stream header contained in the 802.15.4 RF packet. By default (MM = 0), MaxStream Mode is enabled and the module adds an extra header to the data portion of the 802.15.4 packet. This enables the following features:• ND and DN command support• Duplicate packet detection when using ACKsThe MM command allows users to turn off the use of the extra header. Modes 1 and 2 are strict 802.15.4 modes. If the MaxStream header is dis-abled, ND and DN parameters are also disabled.Note: When MM > 0, application and CCA failure retries are not supported.MY (16-bit Source Address) Command<Networking {Addressing}> The MY command is used to set and read the 16-bit source address of the RF module.By setting MY to 0xFFFF, the reception of RF pack-ets having a 16-bit address is disabled. The 64-bit address is the module’s serial number and is always enabled.NB (Parity) Command<Serial Interfacing> The NB command is used to select/read the parity settings of the RF module for UART communications.AT Command: ATMMParameter Range:0 - 2Parameter Configuration0MaxStream Mode (802.15.4 + MaxStream header)1 802.15.4 (no ACKs)2 802.15.4 (with ACKs)Default Parameter Value:0Related Commands: ND (Node Discover), DN (Destination Node) Minimum Firmware Version Required: v1.x80AT Command: ATMYParameter Range: 0 - 0xFFFFDefault Parameter Value: 0Related Commands: DH (Destination Address High), DL (Destination Address Low), CH (Channel), ID (PAN ID)AT Command:  ATNBParameter Range:  0 - 4Parameter Configuration08-bit (no parity or7-bit (any parity)18-bit even28-bit odd38-bit mark48-bit spaceDefault Parameter Value:  0Number of bytes returned:  1
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 47Chapter3‐RFModuleConfigurationND (Node Discover) Command<Networking {Identification}> The ND command is used to discover and report all modules on its current operating channel (CH parameter) and PAN ID (ID parameter). ND also accepts an NI (Node Identifier) value as a parameter. In this case, only a module matching the supplied identi-fier will respond.ND uses a 64-bit long address when sending and responding to an ND request. The ND command causes a module to transmit a globally addressed ND command packet. The amount of time allowed for responses is determined by the NT (Node Discover Time) parameter. In AT Command mode, command completion is designated by a carriage return (0x0D). Since two carriage returns end a command response, the application will receive three carriage returns at the end of the command. If no responses are received, the application should only receive one carriage return. When in API mode, the application should receive a frame (with no data) and sta-tus (set to ‘OK’) at the end of the command. When the ND command packet is received, the remote sets up a random time delay (up to 2.2 sec) before replying as follows:Node Discover Response (AT command mode format - Transparent operation): MY (Source Address) value<CR> SH (Serial Number High) value<CR> SL (Serial Number Low) value<CR> DB (Received Signal Strength) value<CR> NI (Node Identifier) value<CR> <CR>  (This is part of the response and not the end of command indicator.)Node Discover Response (API format - data is binary (except for NI)):   2 bytes for MY (Source Address) value   4 bytes for SH (Serial Number High) value   4 bytes for SL (Serial Number Low) value   1 byte for DB (Received Signal Strength) value   NULL-terminated string for NI (Node Identifier) value (max 20 bytes w/out NULL terminator)NI (Node Identifier) Command<Networking {Identification}> The NI command is used to set and read a string for identifying a particular node. Rules:• Register only accepts printable ASCII data. • A string can not start with a space. • A carriage return ends command• Command will automatically end when maximum bytes for the string have been entered. This string is returned as part of the ND (Node Discover) command. This identifier is also used with the DN (Destination Node) command.NT (Node Discover Time) Command<Networking {Identification}> The NT command is used to set the amount of time a base node will wait for responses from other nodes when using the ND (Node Discover) command. The NT value is transmitted with the ND command. Remote nodes will set up a random hold-off time based on this time. The remotes will adjust this time down by 250 ms to give each node the abil-ity to respond before the base ends the command. Once the ND command has ended, any response received on the base would be discarded.AT Command: ATNDRange: optional 20-character NI valueRelated Commands: CH (Channel), ID (Pan ID), MY (Source Address), SH (Serial Number High), SL (Serial Number Low), NI (Node Identifier), NT (Node Discover Time)Minimum Firmware Version Required: v1.x80AT Command: ATNIParameter Range: 20-character ASCII stringRelated Commands: ND (Node Discover), DN (Destination Node)Minimum Firmware Version Required: v1.x80AT Command: ATNTParameter Range: 0x01 - 0xFC [x 100 msec]Default: 0x19 (2.5 decimal seconds)Related Commands: ND (Node Discover)Minimum Firmware Version Required: 1.xA0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 48Chapter3‐RFModuleConfigurationP0 (PWM0 Configuration) Command<I/O Setting {I/O Line Passing}> The P0 com-mand is used to select/read the function for PWM0 (Pulse Width Modulation output 0). This command enables the option of translating incoming data to a PWM so that the output can be translated back into analog form. With the IA (I/O Input Address) parameter cor-rectly set, AD0 values can automatically be passed to PWM0.P1 (PWM1 Configuration) Command<I/O Setting {I/O Line Passing}> The P1 com-mand is used to select/read the function for PWM1 (Pulse Width Modulation output 1). This command enables the option of translating incoming data to a PWM so that the output can be translated back into analog form. With the IA (I/O Input Address) parameter cor-rectly set, AD1 values can automatically be passed to PWM1.PL (Power Level) Command<RF Interfacing> The PL command is used to select and read the power level at which the RF module transmits conducted power.WHEN OPERATING IN EUROPE:  XBee-PRO RF Modules must be configured to operate at a maximum transmit power output level of 10 dBm. The PL parameter must equal “0” (10 dBm).Additionally, European regulations stipulate an EIRP power maximum of 12.86 dBm (19 mW) for the XBee-PRO and 12.11 dBm for the XBee when integrating high-gain antennas.WHEN OPERATING IN JAPAN: XBee-PRO RF Modules optimized for use in Japan contain firmware that limits transmit power out-put to 10 dBm. If PL=4 (default), the maximum power output level is 10 dBm. For a list of module part numbers approved for use in Japan, contact MaxStream [call 1-801-765-9885 or send e-mail to sales@maxstream.net].AT Command: ATP0 The second character in the command is the number zero (“0”), not the letter “O”.Parameter Range: 0 - 2Parameter Configuration0 Disabled1 RSSI2PWM0 OutputDefault Parameter Value: 1AT Command: ATP1Parameter Range: 0 - 2Parameter Configuration0 Disabled1 RSSI2PWM1 OutputDefault Parameter Value: 0Minimum Firmware Version Required: v1.xA0AT Command:  ATPLParameter Range:  0 - 4Parameter XBee XBee-PRO0 -10 dBm 10 dBm1 -6 dBm 12 dBm2 -4 dBm 14 dBm3 -2 dBm 16 dBm4 0 dBm 18 dBmDefault Parameter Value: 4
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 49Chapter3‐RFModuleConfigurationPR (Pull-up Resistor Enable) Command<Serial Interfacing> The PR command is used to set and read the bit field that is used to configure internal the pull-up resistor status for I/O lines. “1” specifies the pull-up resistor is enabled. “0” specifies no pull up.bit 0 - AD4/DIO4 (pin 11) bit 1 - AD3/DIO3 (pin 17)  bit 2 - AD2/DIO2 (pin 18) bit 3 - AD1/DIO1 (pin 19) bit 4 - AD0/DIO0 (pin 20) bit 5 - AD6/DIO6 (pin 16) bit 6 - DI8 (pin 9)  bit 7 - DIN/CONFIG (pin 3)For example: Sending the command “ATPR 6F” will turn bits 0, 1, 2, 3, 5 and 6 ON; and bits 4 & 7 will be turned OFF. (The binary equivalent of “0x6F” is “01101111”. Note that ‘bit 0’ is the last digit in the bitfield.PT (PWM Output Timeout) Command<I/O Settings {I/O Line Passing}> The PT com-mand is used to set/read the output timeout value for both PWM outputs. When PWM is set to a non-zero value: Due to I/O line passing, a time is started which when expired will set the PWM output to zero. The timer is reset when a valid I/O packet is received.RE (Restore Defaults) Command<(Special)> The RE command is used to restore all configurable parameters to their factory default settings. The RE command does not write restored values to non-volatile (persistent) memory. Issue the WR (Write) command subsequent to issuing the RE command to save restored parameter values to non-volatile memory.RN (Random Delay Slots) Command<Networking & Security> The RN command is used to set and read the minimum value of the back-off exponent in the CSMA-CA algorithm. The CSMA-CA algorithm was engineered for collision avoidance (random delays are inserted to prevent data loss caused by data collisions).If RN = 0, collision avoidance is disabled during the first iteration of the algorithm (802.15.4 - macMinBE).CSMA-CA stands for "Carrier Sense Multiple Access - Collision Avoidance". Unlike CSMA-CD (reacts to network transmissions after collisions have been detected), CSMA-CA acts to prevent data colli-sions before they occur. As soon as a module receives a packet that is to be transmitted, it checks if the channel is clear (no other module is transmitting). If the channel is clear, the packet is sent over-the-air. If the channel is not clear, the module waits for a randomly selected period of time, then checks again to see if the channel is clear. After a time, the process ends and the data is lost.AT Command: ATPRParameter Range: 0 - 0xFFDefault Parameter Value: 0xFF  (all pull-up resistors are enabled)Minimum Firmware Version Required: v1.x80AT Command: ATPTParameter Range: 0 - 0xFF [x 100 msec]Default Parameter Value: 0xFFMinimum Firmware Version Required: 1.xA0AT Command: ATREAT Command: ATRNParameter Range: 0 - 3 [exponent]Default Parameter Value: 0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 50Chapter3‐RFModuleConfigurationRO (Packetization Timeout) Command<Serial Interfacing> RO command is used to set and read the number of character times of inter-character delay required before transmission.RF transmission commences when data is detected in the DI (data in from host) buffer and RO character times of silence are detected on the UART receive lines (after receiving at least 1 byte). RF transmission will also commence after 100 Bytes (maximum packet size) are received in the DI buffer.Set the RO parameter to '0' to transmit characters as they arrive instead of buffering them into one RF packet.RP (RSSI PWM Timer) Command<I/O Settings {I/O Line Passing}> The RP com-mand is used to enable PWM (Pulse Width Modu-lation) output on the RF module. The output is calibrated to show the level a received RF signal is above the sensitivity level of the module. The PWM pulses vary from 24 to 100%. Zero percent means PWM output is inactive. One to 24% per-cent means the received RF signal is at or below the published sensitivity level of the module. The following table shows levels above sensitivity and PWM values.The total period of the PWM output is 64 µs. Because there are 445 steps in the PWM output, the minimum step size is 144 ns.A non-zero value defines the time that the PWM output will be active with the RSSI value of the last received RF packet. After the set time when no RF packets are received, the PWM output will be set low (0 percent PWM) until another RF packet is received. The PWM output will also be set low at power-up until the first RF packet is received. A parameter value of 0xFF permanently enables the PWM output and it will always reflect the value of the last received RF packet.RR (XBee Retries) Command<Networking {Addressing}> The RR command is used set/read the maximum number of retries the module will execute in addition to the 3 retries provided by the 802.15.4 MAC. For each XBee retry, the 802.15.4 MAC can execute up to 3 retries.This values does not need to be set on all modules for retries to work. If retries are enabled, the transmitting module will set a bit in the Maxstream RF Packet header which requests the receiving module to send an ACK (acknowledgement). If the transmitting module does not receive an ACK within 200 msec, it will re-send the packet within a random period up to 48 msec. Each XBee retry can potentially result in the MAC sending the packet 4 times (1 try plus 3 retries). Note that retries are not attempted for packets that are purged when transmitting with a Cyclic Sleep Coordinator.PWMPercentagesdB above Sensitivity PWM percentage(high period / total period)10 41%20 58%30 75%AT Command: ATROParameter Range:0 - 0xFF[x character times]Default Parameter Value: 3AT Command: ATRPParameter Range:0 - 0xFF[x 100 msec]Default Parameter Value: 0x28 (40 decimal)AT Command: ATRRParameter Range: 0 - 6Default: 0Minimum Firmware Version Required: 1.xA0
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 51Chapter3‐RFModuleConfigurationSC (Scan Channels) Command<Networking {Association}> The SC command is used to set and read the list of channels to scan for all Active and Energy Scans as a bit field.This affects scans initiated in command mode [AS (Active Scan) and ED (Energy Scan) commands] and during End Device Association and Coordina-tor startup.bit 0 - 0x0B  bit 4 - 0x0F bit 8 - 0x13bit 12 - 0x17 bit 1 - 0x0C  bit 5 - 0x10 bit 9 - 0x14 bit 13 - 0x18 bit 2 - 0x0D  bit 6 - 0x11 bit 10 - 0x15 bit 14 - 0x19 bit 3 - 0x0E  bit 7 - 0x12 bit 11 - 0x16 bit 15 - 0x1ASD (Scan Duration) Command<Networking {Association}> The SD command is used to set and read the exponent value that determines the duration (in time) of a scan.End Device (Duration of Active Scan during Association) - In a Beacon system, set SD = BE of the Coordinator. SD must be set at least to the highest BE parameter of any Beaconing Coordina-tor with which an End Device or Coordinator wish to discover. Coordinator - If the ‘ReassignPANID’ option is set on the Coordinator [refer to A2 parameter], the SD parameter determines the length of time the Coordinator will scan channels to locate existing PANs. If the ‘ReassignChannel’ option is set, SD determines how long the Coordinator will perform an Energy Scan to determine which channel it will operate on.Scan Time is measured as ((# of Channels to Scan) * (2 ^ SD) * 15.36ms). The number of chan-nels to scan is set by the SC command. The XBee RF Module can scan up to 16 channels (SC = 0xFFFF). The XBee PRO RF Module can scan up to 12 channels (SC = 0x1FFE).SH (Serial Number High) Command<Diagnostics> The SH command is used to read the high 32 bits of the RF module's unique IEEE 64-bit address.The module serial number is set at the factory and is read-only.SL (Serial Number Low) Command<Diagnostics> The SL command is used to read the low 32 bits of the RF module's unique IEEE 64-bit address.The module serial number is set at the factory and is read-only.Examples:Val ue s belowshowresultsfora12‐channelscanIf SD = 0, time = 0.18 sec SD = 8, time = 47.19 secSD = 2, time = 0.74 sec SD = 10, time = 3.15 minSD = 4, time = 2.95 sec SD = 12, time = 12.58 minSD = 6, time = 11.80 sec SD = 14, time = 50.33 minAT Command: ATSCParameter Range: 0 - 0xFFFF [Bitfield] (bits 0, 14, 15 are not allowed when using the XBee-PRO)Default Parameter Value: 0x1FFE (all XBee-PRO channels)Related Commands: ED (Energy Scan), SD (Scan Duration)Minimum Firmware Version Required: v1.x80AT Command: ATSDParameter Range: 0 - 0x0FDefault Parameter Value: 4Related Commands: ED (Energy Scan), SC (Scan Channel)Minimum Firmware Version Required: v1.x80AT Command: ATSHParameter Range: 0 - 0xFFFFFFFF [read-only]Related Commands: SL (Serial Number Low), MY (Source Address)AT Command: ATSLParameter Range: 0 - 0xFFFFFFFF [read-only]Related Commands: SH (Serial Number High), MY (Source Address)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 52Chapter3‐RFModuleConfigurationSM (Sleep Mode) Command<Sleep Mode (Low Power)> The SM command is used to set and read Sleep Mode settings. By default, Sleep Modes are disabled (SM = 0) and the RF module remains in Idle/Receive Mode. When in this state, the module is constantly ready to respond to either serial or RF activity.SM command options vary according to the net-working system type. By default, the module is configured to operate in a NonBeacon system.* The Sleep Coordinator option (SM=6) only exists for backwards compatibility with firmware version 1.x06 only. In all other cases, use the CE command to enable a Coordinator.SP (Cyclic Sleep Period) Command<Sleep Mode (Low Power)> The SP command is used to set and read the duration of time in which a remote RF module sleeps. After the cyclic sleep period is over, the module wakes and checks for data. If data is not present, the module goes back to sleep. The maximum sleep period is 268 sec-onds (SP = 0x68B0).The SP parameter is only valid if the module is configured to operate in Cyclic Sleep (SM = 4-6). Coordinator and End Device SP values should always be equal. To send Direct Messages, set SP = 0.NonBeacon FirmwareEnd Device - SP determines the sleep period for cyclic sleeping remotes. Maximum sleep period is 268 seconds (0x68B0).Coordinator - If non-zero, SP determines the time to hold an indirect message before discarding it. A Coordinator will discard indirect messages after a period of (2.5 * SP).ST (Time before Sleep) Command<Sleep Mode (Low Power)> The ST command is used to set and read the period of inactivity (no serial or RF data is sent or received) before acti-vating Sleep Mode.NonBeacon FirmwareSet/Read time period of inactivity (no serial or RF data is sent or received) before activating Sleep Mode. ST parameter is only valid with Cyclic Sleep settings (SM = 4 - 5).Coordinator and End Device ST values must be equal.AT Command: ATSMParameter Range: 0 - 6     Parameter Configuration0Disabled1Pin Hibernate2Pin Doze3(reserved)4 Cyclic Sleep Remote5Cyclic Sleep Remote(with Pin Wake-up)6 Sleep Coordinator*Default Parameter Value: 0Related Commands: SP (Cyclic Sleep Period), ST (Time before Sleep)AT Command: ATSPParameter Range:NonBeacon Firmware: 1 - 0x68B0 [x 10 milliseconds]Default Parameter Value:NonBeacon Firmware: 0Related Commands: SM (Sleep Mode), ST (Time before Sleep), DP (Disassociation Cyclic Sleep Period, BE (Beacon Order)AT Command: ATSTParameter Range:NonBeacon Firmware: 1 - 0xFFFF [x 1 millisecond]Default Parameter Value:NonBeacon Firmware: 0x1388  (5000 decimal)Related Commands: SM (Sleep Mode), ST (Time before Sleep)
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 53Chapter3‐RFModuleConfigurationT0 - T7 ((D0-D7) Output Timeout) Command<I/O Settings {I/O Line Passing}> The T0, T1, T2, T3, T4, T5, T6 and T7 commands are used to set/read output timeout values for the lines that correspond with the D0 - D7 parameters. When output is set (due to I/O line passing) to a non-default level, a timer is started which when expired, will set the output to its default level. The timer is reset when a valid I/O packet is received. The Tn parameter defines the permissible amount of time to stay in a non-default (active) state. If Tn = 0, Output Timeout is disabled (output levels are held indefinitely).VL (Firmware Version - Verbose)<Diagnostics> The VL command is used to read  detailed version information about the RF module. The information includes:  application build date; MAC, PHY and bootloader versions; and build dates.VR (Firmware Version) Command<Diagnostics> The VR command is used to read which firmware version is stored in the module. XBee version numbers will have four significant digits. The reported number will show three or four numbers and is stated in hexadecimal notation. A version can be reported as "ABC" or "ABCD". Digits ABC are the main release number and D is the revision number from the main release. "D" is not required and if it is not present, a zero is assumed for D. "B" is a variant desig-nator. The following variants exist:• "0" = Non-Beacon Enabled 802.15.4 Code• "1" = Beacon Enabled 802.15.4 CodeWR (Write) Command<(Special)> The WR command is used to write configurable parameters to the RF module's non-volatile memory. Parameter values remain in the module's memory until overwritten by subsequent use of the WR Command. If changes are made without writing them to non-volatile memory, the module reverts back to pre-viously saved parameters the next time the module is powered-on.NOTE: Once the WR command is sent to the module, no additional characters should be sent until after the “OK/r” response is received.AT Commands: ATT0 - ATT7Parameter Range:0 - 0xFF [x 100 msec]Default Parameter Value:0xFFMinimum Firmware Version Required: v1.xA0AT Command: ATVLParameter Range:0 - 0xFF[x 100 milliseconds]Default Parameter Value: 0x28 (40 decimal)Minimum Firmware Version Required: v1.x80AT Command: ATVRParameter Range: 0 - 0xFFFF [read only]AT Command: ATWR
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 54Chapter3‐RFModuleConfiguration3.4. API OperationBy default, XBee/XBee-PRO RF Modules act as a serial line replacement (Transparent Operation) - all UART data received through the DI pin is queued up for RF transmission. When the module receives an RF packet, the data is sent out the DO pin with no additional information.Inherent to Transparent Operation are the following behaviors:• If module parameter registers are to be set or queried, a special operation is required for transitioning the module into Command Mode.• In point-to-multipoint systems, the application must send extra information so that the receiving module(s) can distinguish between data coming from different remotes.As an alternative to the default Transparent Operation, API (Application Programming Interface) Operations are available. API operation requires that communication with the module be done through a structured interface (data is communicated in frames in a defined order). The API spec-ifies how commands, command responses and module status messages are sent and received from the module using a UART Data Frame.3.4.1. API Frame SpecificationsTwo API modes are supported and both can be enabled using the AP (API Enable) command. Use the following AP parameter values to configure the module to operate in a particular mode:• AP = 0 (default): Transparent Operation (UART Serial line replacement) API modes are disabled.•AP = 1: API Operation•AP = 2: API Operation (with escaped characters)Any data received prior to the start delimiter is silently discarded. If the frame is not received cor-rectly or if the checksum fails, the data is silently discarded.API Operation (AP parameter = 1)When this API mode is enabled (AP = 1),  the UART data frame structure is defined as follows:Figure3‐01. UARTDataFrameStructure:MSB=MostSignificantByte,LSB=LeastSignificantByteAPI Operation - with Escape Characters (AP parameter = 2)When this API mode is enabled (AP = 2), the UART data frame structure is defined as follows:Figure3‐02. UARTDataFrameStructure‐withescapecontrolcharacters:MSB=MostSignificantByte,LSB=LeastSignificantByteEscape characters. When sending or receiving a UART data frame, specific data values must be escaped (flagged) so they do not interfere with the UART or UART data frame operation. To escape an interfering data byte, insert 0x7D and follow it with the byte to be escaped XOR’d with 0x20.Start Delimiter(Byte 1) Length(Bytes 2-3) Frame Data(Bytes 4-n) Checksum(Byte n + 1)0x7E MSB LSB API-specific Structure 1 ByteStart Delimiter(Byte 1) Length(Bytes 2-3) Frame Data(Bytes 4-n) Checksum(Byte n + 1)0x7E MSB LSB API-specific Structure 1 ByteCharacters Escaped If Needed
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 55Chapter3‐RFModuleConfigurationData bytes that need to be escaped:• 0x7E – Frame Delimiter•0x7D – Escape• 0x11 – XON• 0x13 – XOFFNote: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as: 0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB.ChecksumTo test data integrity, a checksum is calculated and verified on non-escaped data.To calculate: Not including frame delimiters and length, add all bytes keeping only the lowest 8 bits of the result and subtract from 0xFF.To verify: Add all bytes (include checksum, but not the delimiter and length). If the checksum is correct, the sum will equal 0xFF.3.4.2. API TypesFrame data of the UART data frame forms an API-specific structure as follows:Figure3‐03. UARTDataFrame&API‐specificStructure:The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData frame (Identifier-specific data). Refer to the sections that follow for more information regarding the supported API types. Note that multi-byte values are sent big endian.Modem StatusAPI Identifier: 0x8A RF module status messages are sent from the module in response to specific conditions.Figure3‐04. ModemStatusFramesExample -  Raw UART Data Frame (before escaping interfering bytes):       0x7E 0x00 0x02 0x23 0x11 0xCB0x11 needs to be escaped which results in the following frame:   0x7E 0x00 0x02 0x23 0x7D 0x31 0xCBLength(Bytes 2-3) Checksum(Byte n + 1)MSB LSB 1 ByteStart Delimiter(Byte 1)0x7EFrame Data(Bytes 4-n)API-specific StructureIdentifier-specific DatacmdDataAPI IdentifiercmdIDcmdData0x8ALength ChecksumStart Delimiter Frame DataIdentifier-specific D ataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureStatus (Byte 5)0 = Hardware reset1 = Watchdog timer reset2 = Associated3 = Disassociated4 = Synchronization Lost      (Beacon-enabled only)5 = Coordinator realignment6 = Coordinator started
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 56Chapter3‐RFModuleConfigurationAT CommandAPI Identifier Value: 0x08 The “AT Command” API type allows for module parameters to be queried or set. When using this command ID, new parameter values are applied immediately. This includes any register set with the “AT Command - Queue Parameter Value” (0x09) API type.Figure3‐05. ATCommandFramesFigure3‐06. Example:APIframeswhenreadingtheDLparametervalueofthemodule.Figure3‐07. Example:APIframeswhenmodifyingtheDLparametervalueofthemodule.AT Command - Queue Parameter ValueAPI Identifier Value: 0x09 This API type allows module parameters to be queried or set. In contrast to the “AT Command” API type, new parameter values are queued and not applied until either the “AT Command” (0x08) API type or the AC (Apply Changes) command is issued. Register queries (reading parameter values) are returned immediately.Figure3‐08. ATCommandFrames (Notethatframesareidenticaltothe“ATCommand”APItypeexceptfortheAPIidentifier.)cmdData0x08Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5)Identifies the UART data frame for the host tocorrelate with a subsequent ACK (acknowledgement).If set to ‘0’, no response is sent.AT Command (Bytes 6-7)Command Name - TwoASCII characters thatidentify the AT Command.Parameter Value (Byte(s) 8-n)If present, indicates the requested parametervalue to set the given register.If no characters present, register is queried.*Length[Bytes]=APIIdentifier+FrameID+ATCommand**“R”valuewasarbitrarilyselected.Checksum0x15Byte 8AT CommandBytes 6-7Frame ID**0x52 (R)Byte 50x44 (D) 0x4C (L)API Identifier0x08Byte 4Start DelimiterByte 10x7ELength*Bytes 2-30x00 0x04*Length[Bytes]=APIIdentifier+FrameID+ATCommand+ParameterValue**“M”valuewasarbitrarilyselected.Checksum0x0CByte 12AT CommandBytes 6-70x44 (D) 0x4C (L)Parameter Value0x00000FFFBytes 8-11Frame ID**0x4D (M)Byte 5Length*Bytes 2-30x00 0x08API Identifier0x08Byte 4Start DelimiterByte 10x7EcmdData0x09Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5)Identifies the UART data frame for the host tocorrelate with a subsequent ACK (acknowledgement).If set to ‘0’, no response is requested.AT Command (Bytes 6-7)Command Name - TwoASCII characters thatidentify the AT Command.Parameter Value (Byte(s) 8-n)If present, indicates the requested parametervalue to set the given register.If no characters present, register is queried.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 57Chapter3‐RFModuleConfigurationAT Command ResponseAPI Identifier Value: 0x88 Response to previous command.In response to an AT Command message, the module will send an AT Command Response mes-sage. Some commands will send back multiple frames (for example, the ND (Node Discover) and AS (Active Scan) commands). These commands will end by sending a frame with a status of ATCMD_OK and no cmdData.Figure3‐09. ATCommandResponseFrames.TX (Transmit) Request: 64-bit addressAPI Identifier Value: 0x00 A TX Request message will cause the module to send RF Data as an RF Packet.Figure3‐10. TXPacket(64‐bitaddress)FramesTX (Transmit) Request: 16-bit addressAPI Identifier Value: 0x01 A TX Request message will cause the module to send RF Data as an RF Packet.Figure3‐11. TXPacket(16‐bitaddress)FramescmdData0x88Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5 )Identifies the UART data frame being reported.Note: If Frame ID = 0 in AT Command Mode,no AT Command Response will be given.AT Command (Bytes 6-7)Command Name - TwoASCII characters thatidentify the AT Command.Status (Byte 8)0 = OK1 = ERRORValue (Byte(s) 9-n)The HEX (non-ASCII) valueof the requested registercmdData0x00Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5)Identifies the UART data frame for the host tocorrelate with a subsequent ACK (acknowledgement).Setting Frame ID to ‘0' will disable response frame.Destination Address (Bytes 6-13)MSB first, LSB last.Broadcast =0x000000000000FFFFOptions (Byte 14)0x01 = Disable ACK0x04 = Send packet with Broadcast Pan IDAll other bits must be set to 0.RF Data (Byte(s) 15-n)Up to 100 Bytes per packetcmdData0x01Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5)Identifies the UART data frame for the host tocorrelate with a subsequent ACK (acknowledgement).Setting Frame ID to ‘0' will disable response frame.Destination Address (Bytes 6-7)MSB first, LSB last.Broadcast = 0xFFFFOptions (Byte 8)0x01 = Disable ACK0x04 = Send packet with Broadcast Pan IDAll other bits must be set to 0.RF Data (Byte(s) 9-n)Up to 100 Bytes per packet
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 58Chapter3‐RFModuleConfigurationTX (Transmit) StatusAPI Identifier Value: 0x89 When a TX Request is completed, the module sends a TX Status message. This message will indi-cate if the packet was transmitted successfully or if there was a failure.Figure3‐12. TXStatusFramesNOTES:• “STATUS = 1” occurs when all retries are expired and no ACK is received.• If transmitter broadcasts (destination address = 0x000000000000FFFF), only  “STATUS = 0 or 2” will be returned.• “STATUS = 3” occurs when Coordinator times out of an indirect transmission.  Timeout is defined as (2.5 x SP (Cyclic Sleep Period) parameter value).RX (Receive) Packet: 64-bit AddressAPI Identifier Value: 0x80 When the module receives an RF packet, it is sent out the UART using this message type.Figure3‐13. RXPacket(64‐bitaddress)FramesRX (Receive) Packet: 16-bit AddressAPI Identifier Value: 0x81 When the module receives an RF packet, it is sent out the UART using this message type.Figure3‐14. RXPacket(16‐bitaddress)FramescmdData0x89Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific StructureFrame ID (Byte 5) Status (Byte 6)0 = Success1 = No ACK (Acknowledgement) received2 = CCA failure3 = PurgedIdentifies UART data frame being reported.Note: If Frame ID = 0 in the TX Request, noAT Command Response will be given.cmdData0x80Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific Structurebit 0 [reserved]bit 1 = Address broadcastbit 2 = PAN broadcastbits 3-7 [reserved]Up to 100 Bytes per packetReceived Signal Strength Indicator -Hexadecimal equivalent of (-dBm) value.(For example: If RX signal strength = -40dBm, “0x28” (40 decimal) is returned)Source Address (Bytes 5-12) Options (Byte 14) RF Data (Byte(s) 15-n)RSSI (Byte 13)MSB (most significant byte) first,LSB (least significant) lastcmdData0x81Length ChecksumStart Delimiter Frame DataIdentifier-specific DataAPI IdentifierMSB LSB0x7E 1 ByteAPI-specific Structurebit 0 [reserved]bit 1 = Address broadcastbit 2 = PAN broadcastbits 3-7 [reserved]Up to 100 Bytes per packetReceived Signal Strength Indicator -Hexadecimal equivalent of (-dBm) value.(For example: If RX signal strength = -40dBm, “0x28” (40 decimal) is returned)Source Address (Bytes 5-6) RSSI (Byte 7)MSB (most significant byte) first,LSB (least significant) lastOptions (Byte 8) RF Data (Byte(s) 9-n)
©2007MaxStream,Inc. 59AppendixA:AgencyCertificationsUnited States (FCC)XBee/XBee-PRO RF Modules comply with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.To fulfill FCC Certification requirements, the OEM must comply with the following regulations:OEM Labeling RequirementsWARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown in the figure below.FigureA‐01. RequiredFCCLabelforOEMproductscontainingtheXBee/XBee‐PRORFModule*TheFCCIDfortheXBeeis“OUR‐XBEE”.TheFCCIDfortheXBee‐PROis“OUR‐XBEEPRO”.FCC NoticesIMPORTANT: The XBee/XBee-PRO OEM RF Module has been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Modifications not expressly approved by MaxStream could void the user's authority to operate the equipment.IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.IMPORTANT: The RF module has been certified for remote and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the inter-ference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help.1. The system integrator must ensure that the text on the external label provided with this device is placed on the outside of the final product [Figure A-01].2. XBee/XBee-PRO RF Modules may only be used with antennas that have been tested and approved for use with this module [refer to the antenna tables in this section].Contains FCC ID: OUR-XBEE/OUR-XBEEPRO**The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any inter-ference received, including interference that may cause undesired operation.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 60AppendixA:AgencyCertificationsFCC-Approved Antennas (2.4 GHz)XBee/XBee-PRO RF Modules can be installed using antennas and cables constructed with standard connectors (Type-N, SMA, TNC, etc.) if the installation is performed professionally and according to FCC guidelines. For installations not performed by a professional, non-standard connectors (RPSMA, RPTNC, etc) must be used.The modules are FCC-approved for fixed base station and mobile applications on channels 0x0B - 0x1A (XBee) and 0x0C - 0x17 (XBee-PRO). If the antenna is mounted at least 20cm (8 in.) from nearby persons, the application is considered a mobile application. Antennas not listed in the table must be tested to comply with FCC Section 15.203 (Unique Antenna Connectors) and Section 15.247 (Emissions).XBee OEM RF Modules (1 mW): XBee Modules have been tested and approved for use with all of the antennas listed in the tables below (Cable-loss IS NOT required).XBee-PRO OEM RF Modules (60 mW): XBee-PRO Modules have been tested and approved for use with the antennas listed in the tables below (Cable-loss IS required when using antennas listed in Table A-02).TableA‐01. AntennasapprovedforusewiththeXBee/XBee‐PRORFModules(Cable‐lossisnotrequired.)TableA‐02. AntennasapprovedforusewiththeXBeeRFModules(Cable‐lossisrequired)Part Number Type (Description) Gain Application* Min. SeparationA24-HSM-450 Dipole (Half-wave articulated RPSMA - 4.5”) 2.1 dBi Fixed/Mobile 20 cmA24-HABSM Dipole (Articulated RPSMA) 2.1 dBi Fixed 20 cmA24-HABUF-P5I Dipole (Half-wave articulated bulkhead mount U.FL. w/ 5” pigtail) 2.1 dBi Fixed 20 cmA24-QI Monopole (Integrated whip) 1.5 dBi Fixed 20 cmPart Number Type (Description) Gain Application* Min. Separation Required Cable-lossOmni-Directional Class AntennasA24-Y6NF Yagi (6-element) 8.8 dBi Fixed 2 m 1.7 dBA24-Y7NF Yagi (7-element) 9.0 dBi Fixed 2 m 1.9 dBA24-Y9NF Yagi (9-element) 10.0 dBi Fixed 2 m 2.9 dBA24-Y10NF Yagi (10-element) 11.0 dBi Fixed 2 m 3.9 dBA24-Y12NF Yagi (12-element) 12.0 dBi Fixed 2 m 4.9 dBA24-Y13NF Yagi (13-element) 12.0 dBi Fixed 2 m 4.9 dBA24-Y15NF Yagi (15-element) 12.5 dBi Fixed 2 m 5.4 dBA24-Y16NF Yagi (16-element) 13.5 dBi Fixed 2 m 6.4 dBA24-Y16RM Yagi (16-element, RPSMA connector) 13.5 dBi Fixed 2 m 6.4 dBA24-Y18NF Yagi (18-element) 15.0 dBi Fixed 2 m 7.9 dBOmni-Directional Class AntennasA24-C1 Surface Mount -1.5 dBi Fixed/Mobile 20 cm -A24-F2NF Omni-directional (Fiberglass base station) 2.1 dBi Fixed/Mobile 20 cmA24-F3NF Omni-directional (Fiberglass base station) 3.0 dBi Fixed/Mobile 20 cmA24-F5NF Omni-directional (Fiberglass base station) 5.0 dBi Fixed/Mobile 20 cmA24-F8NF Omni-directional (Fiberglass base station) 8.0 dBi Fixed 2 mA24-F9NF Omni-directional (Fiberglass base station) 9.5 dBi Fixed 2 m 0.2 dBA24-F10NF Omni-directional (Fiberglass base station) 10.0 dBi Fixed 2 m 0.7 dBA24-F12NF Omni-directional (Fiberglass base station) 12.0 dBi Fixed 2 m 2.7 dBA24-F15NF Omni-directional (Fiberglass base station) 15.0 dBi Fixed 2 m 5.7 dBA24-W7NF Omni-directional (Base station) 7.2 dBi Fixed 2 mA24-M7NF Omni-directional (Mag-mount base station) 7.2 dBi Fixed 2 mPanel Class AntennasA24-P8SF Flat Panel 8.5 dBi Fixed 2 m 1.5 dBA24-P8NF Flat Panel 8.5 dBi Fixed 2 m 1.5 dBA24-P13NF Flat Panel 13.0 dBi Fixed 2 m 6 dBA24-P14NF Flat Panel 14.0 dBi Fixed 2 m 7 dBA24-P15NF Flat Panel 15.0 dBi Fixed 2 m 8 dBA24-P16NF Flat Panel 16.0 dBi Fixed 2 m 9 dB
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 61AppendixA:AgencyCertificationsTableA‐03. AntennasapprovedforusewiththeXBee/XBee‐PRORFModules(Cable‐lossisrequired)*IfusingtheRFmoduleinaportableapplication(Forexample‐Ifthemoduleisusedinahandhelddeviceandtheantennaislessthan20cmfromthehumanbodywhenthedeviceisoperation):TheintegratorisresponsibleforpassingadditionalSAR(SpecificAbsorptionRate)testingbasedonFCCrules2.1091andFCCGuidelinesforHumanExposuretoRadioFrequencyElectromagneticFields,OETBulletinandSupplementC.ThetestingresultswillbesubmittedtotheFCCforapprovalpriortosellingtheintegratedunit.TherequiredSARtestingmeasuresemissionsfromthemoduleandhowtheyaffecttheperson.RF ExposureWARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users of FCC RF Exposure compliance.Part Number Type (Description) Gain Application* Min. Separation Required Cable-lossA24-C1 Surface Mount -1.5 dBi Fixed/Mobile 20 cm -A24-Y4NF Yagi (4-element) 6.0 dBi Fixed 2 m 8.1 dBA24-Y6NF Yagi (6-element) 8.8 dBi Fixed 2 m 10.9 dBA24-Y7NF Yagi (7-element) 9.0 dBi Fixed 2 m 11.1 dBA24-Y9NF Yagi (9-element) 10.0 dBi Fixed 2 m 12.1 dBA24-Y10NF Yagi (10-element) 11.0 dBi Fixed 2 m 13.1 dBA24-Y12NF Yagi (12-element) 12.0 dBi Fixed 2 m 14.1 dBA24-Y13NF Yagi (13-element) 12.0 dBi Fixed 2 m 14.1 dBA24-Y15NF Yagi (15-element) 12.5 dBi Fixed 2 m 14.6 dBA24-Y16NF Yagi (16-element) 13.5 dBi Fixed 2 m 15.6 dBA24-Y16RM Yagi (16-element, RPSMA connector) 13.5 dBi Fixed 2 m 15.6 dBA24-Y18NF Yagi (18-element) 15.0 dBi Fixed 2 m 17.1 dBA24-F2NF Omni-directional (Fiberglass base station) 2.1 dBi Fixed/Mobile 20 cm 4.2 dBA24-F3NF Omni-directional (Fiberglass base station) 3.0 dBi Fixed/Mobile 20 cm 5.1 dBA24-F5NF Omni-directional (Fiberglass base station) 5.0 dBi Fixed/Mobile 20 cm 7.1 dBA24-F8NF Omni-directional (Fiberglass base station) 8.0 dBi Fixed 2 m 10.1 dBA24-F9NF Omni-directional (Fiberglass base station) 9.5 dBi Fixed 2 m 11.6 dBA24-F10NF Omni-directional (Fiberglass base station) 10.0 dBi Fixed 2 m 12.1 dBA24-F12NF Omni-directional (Fiberglass base station) 12.0 dBi Fixed 2 m 14.1 dBA24-F15NF Omni-directional (Fiberglass base station) 15.0 dBi Fixed 2 m 17.1 dBA24-W7NF Omni-directional (Base station) 7.2 dBi Fixed 2 m 9.3 dBA24-M7NF Omni-directional (Mag-mount base station) 7.2 dBi Fixed 2 m 9.3 dBA24-P8SF Flat Panel 8.5 dBi Fixed 2 m 8.6 dBA24-P8NF Flat Panel 8.5 dBi Fixed 2 m 8.6 dBA24-P13NF Flat Panel 13.0 dBi Fixed 2 m 13.1 dBA24-P14NF Flat Panel 14.0 dBi Fixed 2 m 14.1 dBA24-P15NF Flat Panel 15.0 dBi Fixed 2 m 15.1 dBA24-P16NF Flat Panel 16.0 dBi Fixed 2 m 16.1 dBA24-P19NF Flat Panel 19.0 dBi Fixed 2 m 19.1 dB
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 62AppendixA:AgencyCertificationsEurope (ETSI)The XBee/XBee-PRO RF Module has been certified for use in several European countries. For a complete list, refer to www.maxstream.net.If the XBee/XBee-PRO RF Modules are incorporated into a product, the manufacturer must ensure compliance of the final product to the European harmonized EMC and low-voltage/safety stan-dards. A Declaration of Conformity must be issued for each of these standards and kept on file as described in Annex II of the R&TTE Directive. Furthermore, the manufacturer must maintain a copy of the XBee/XBee-PRO user manual docu-mentation and ensure the final product does not exceed the specified power ratings, antenna specifications, and/or installation requirements as specified in the user manual. If any of these specifications are exceeded in the final product, a submission must be made to a notified body for compliance testing to all required standards.OEM Labeling RequirementsThe 'CE' marking must be affixed to a visible location on the OEM product.FigureA‐02. CELabelingRequirementsThe CE mark shall consist of the initials "CE" taking the following form:• If the CE marking is reduced or enlarged, the proportions given in the above graduated draw-ing must be respected.• The CE marking must have a height of at least 5mm except where this is not possible on account of the nature of the apparatus.• The CE marking must be affixed visibly, legibly, and indelibly.RestrictionsPower Output: The power output of the XBee-PRO RF Modules must not exceed 10 dBm. The power level is set using the PL command and the PL parameter must equal “0” (10 dBm).France: France imposes restrictions on the 2.4 GHz band. Go to www.art-telecom.Fr or contact MaxStream for more information.Norway: Norway prohibits operation near Ny-Alesund in Svalbard. More information can be found at the Norway Posts and Telecommunications site (www.npt.no).Declarations of ConformityMaxStream has issued Declarations of Conformity for the XBee/XBee-PRO RF Modules concerning emissions, EMC and safety. Files are located in the 'documentation' folder of the MaxStream CD.Important NoteMaxStream does not list the entire set of standards that must be met for each country. MaxStream customers assume full responsibility for learning and meeting the required guidelines for each country in their distribution market. For more information relating to European compliance of an OEM product incorporating the XBee/XBee-PRO RF Module, contact MaxStream, or refer to the fol-lowing web sites:CEPT ERC 70-03E - Technical Requirements, European restrictions and general requirements: Available at www.ero.dk/.R&TTE Directive - Equipment requirements, placement on market: Available at www.ero.dk/.
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 63AppendixA:AgencyCertificationsApproved AntennasWhen integrating high-gain antennas, European regulations stipulate EIRP power maximums. Use the following guidelines to determine which antennas to design into an application.XBee OEM RF ModuleThe following antenna types have been tested and approved for use with the XBee Module:Antenna Type: Yagi RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maxi-mum of 14 dBm). Any Yagi type antenna with 14 dBi gain or less can be used with no cable-loss.Antenna Type: Omni-directional RF module was tested and approved with 15 dBi antenna gain with 1 dB cable-loss (EIRP Maxi-mum of 14 dBm). Any Omni-directional type antenna with 14 dBi gain or less can be used with no cable-loss.Antenna Type: Flat Panel RF module was tested and approved with 19 dBi antenna gain with 4.8 dB cable-loss (EIRP Maxi-mum of 14.2 dBm). Any Flat Panel type antenna with 14.2 dBi gain or less can be used with no cable-loss.XBee-PRO OEM RF Module (@ 10 dBm Transmit Power, PL parameter value must equal 0)The following antennas have been tested and approved for use with the embedded XBee-PRO RF Module:• Dipole (2.1 dBi, Omni-directional, Articulated RPSMA, MaxStream part number A24-HABSM)• Chip Antenna (-1.5 dBi)• Attached Monopole Whip (1.5 dBi)The RF modem encasement was designed to accommodate the RPSMA antenna option.Canada (IC)Labeling RequirementsLabeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text:Contains Model XBee Radio, IC: 4214A-XBEE Contains Model XBee-PRO Radio, IC: 4214A-XBEEPROThe integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B - Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003.JapanIn order to gain approval for use in Japan, the XBee-PRO RF Module must contain firmware that limits its transmit power output to 10 dBm. For a list of module part numbers approved for use in Japan, contact MaxStream [call 1-801-765-9885 or send e-mail to sales@maxstream.net].Labeling RequirementsA clearly visible label on the outside of the final product enclosure must display the following text:ID: 005NYCA0378
©2007MaxStream,Inc. 63AppendixB:DevelopmentGuideDevelopment Kit ContentsThe XBee Professional Development Kit includes the hardware and software needed to rapidly cre-ate long range wireless data links between devices (XBee and XBee-PRO Starter Kits, that contain fewer modules and accessories, are also available).Interfacing OptionsThe development kit includes an RS-232 and a USB interface board. Both boards provide a direct connection to many serial devices and therefore provide access to the RF module registries. Parameters stored in the registry allow OEMs and integrators to customize the modules to suite the needs of their data radio systems.The following sections illustrate how to use the interface boards for development purposes. The MaxStream Interface board provides means for connecting the module to any node that has an available RS-232 or USB connector. Since the module requires signals to enter at TTL voltages, one of the main functions of the interface board is to convert signals between TTL levels and RS-232 and USB levels.Note: In the following sections, an OEM RF Module mounted to an interface board will be referred to as a "Module Assembly".TableB‐01. ItemsIncludedintheDevelopmentKit(Professional)Item Qty. Description Part #XBee-PRO Module 2 (1) OEM RF Module w/ U.FL antenna connector(1) OEM RF Module w/ attached wire antenna XBP24-AUI-001XBP24-AWI-001XBee Module 3 (1) OEM RF Module w/ U.FL antenna connector (1) OEM RF Module w/ attached whip antenna(1) OEM RF Module w/ chip antennaXB24-AUI-001XB24-AWI-001XB24-ACI-001RS-232 Development Board 4 Board for interfacing between modules and RS-232 devices(Converts signal levels, displays diagnostic info, & more) XBIB-RUSB Development Board 1 Board for interfacing between modules & USB devices(Converts signal levels, displays diagnostic info, & more) XBIB-URS-232 Cable (6’, straight-through) 1Cable for connecting RS-232 interface board with DTE devices(devices that have a male serial DB-9 port - such as most PCs) JD2D3-CDS-6FUSB Cable (6’) 1 Cable for connecting USB interface board to USB devices JU1U2-CSB-6FSerial Loopback Adapter 1[Red] Adapter for configuring the module assembly (module + RS-232interface board) to function as a repeater for range testing JD2D3-CDL-ANULL Modem Adapter (male-to-male) 1[Black] Adapter for connecting the module assembly (module + RS-232interface board) to other DCE (female DB-9) devices JD2D2-CDN-ANULL Modem Adapter (female-to-female) 1[Gray] Adapter for connecting serial devices. It allows users to bypass  the radios to verify serial cabling is functioning properly. JD3D3-CDN-APower Adapter (9VDC, 1 A) 1 Adapter for powering the RS-232 development board JP5P2-9V11-6FBattery Clip (9V) 1 Clip for remotely powering the RS-232 board w/ a 9V battery JP2P3-C2C-4IRPSMA Antenna 2 RPSMA half-wave dipole antenna (2.4 GHz, 2.1 dB) A24-HASM-450RF Cable Assembly 2 Adapter for connecting RPSMA antenna to U.FL connector JF1R6-CR3-4ICD 1 Documentation and Software MD0030Quick Start Guide 1 Step-by-step instruction on how to create wireless links & test range capabilities of the modules MD0026
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 64AppendixB:DevelopmentGuideRS-232 Development BoardExternal Interface B-01a. Reset SwitchFigureB‐01. FrontView The Reset Switch is used to reset (re-boot) the RF module. This switch only applies when using the configuration tabs of MaxStream’s X-CTU Software. B-01b. I/O & Power LEDsLEDs indicate RF module activity as follows:Yellow (top LED) = Serial Data Out (to host)Green (middle)  = Serial Data In (from host)Red (bottom)  = Power/Association Indicator (Refer to the D5 (DIO5 Configuration) parameter) B-01c. Serial PortStandard female DB-9 (RS-232) connector. B-01d. RSSI LEDsRSSI LEDs indicate the amount of fade margin present in an active wireless link. Fade margin is defined as the difference between the incoming signal strength and the module's receiver sensitivity.3 LEDs ON = Very Strong Signal (> 30 dB fade margin)2 LEDs ON = Strong Signal (> 20 dB fade margin)1 LED ON = Moderate Signal (> 10 dB fade margin)0 LED ON = Weak Signal (< 10 dB fade margin) B-01e. Power Connector5-14 VDC power connector B-02a. DIP SwitchFigureB‐02. BackView DIP Switch functions are not supported in this release. Future down-loadable firmware versions will support DIP Switch configurations.B‐01a.ConfigSwitchB‐01b.I/O&PowerLEDsB‐01c.DB‐9SerialPortB‐01dRSSILEDsB‐01e.PowerConnectorB‐02a.DIPSwitch
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 65AppendixB:DevelopmentGuideRS-232 Pin SignalsFigureB‐03. PinsusedonthefemaleRS‐232(DB‐9)SerialConnector*Functionslistedintheimplementationcolumnmaynotbeavailableatthetimeofrelease.TableB‐02. PinAssignmentsandImplementationsDB-9 Pin RS-232 Name Description Implementation1 DCD Data-Carrier-Detect Connected to DSR (pin6)2 RXD Receive Data Serial data exiting the module assembly (to host)3 TXD Transmit Data Serial data entering into the module assembly (from host)4 DTR Data-Terminal-Ready Can enable Power-down on the module assembly5 GND Ground Signal Ground6 DSR Data-Set-Ready Connected to DCD (pin1)7RTS / CMD Request-to-Send / Command Mode Enables RTS flow control orCommand Mode8CTS Clear-to-Send Provides CTS flow control9 RI Ring Indicator Optional power input that is connected internally to the positive lead of the front power connector
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 66AppendixB:DevelopmentGuideWiring DiagramsFigureB‐04. DTEDevice(RS‐232,maleDB‐9connector)wiredtoaDCEModuleAssembly(femaleDB‐9)FigureB‐05. DCEModuleAssembly(femaleDB‐9connector)wiredtoaDCEDevice(RS‐232,maleDB‐9) Sample Wireless Connection: DTE <--> DCE <--> DCE <--> DCEFigureB‐06. TypicalwirelesslinkbetweenDTEandDCEdevices
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 67AppendixB:DevelopmentGuideAdaptersThe development kit includes several adapters that support the following functions:• Performing Range Tests• Testing Cables• Connecting to other RS-232 DCE and DTE devices• Connecting to terminal blocks or RJ-45 (for RS-485/422 devices)NULL Modem Adapter (male-to-male)Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is used to connect two DCE devices. A DCE device connects with a straight-through cable to the male serial port of a computer (DTE).FigureB‐07. MaleNULLmodemadapterandpinoutsFigureB‐08. ExampleofaMaxStreamRadioModem(DCEDevice)connectingtoanotherDCEdevice)NULL Modem Adapter (female-to-female)Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is used to verify serial cabling is functioning properly. To test cables, insert the female-to-female NULL modem adapter in place of a pair of module assemblies (RS-232 interface board + XTend Module) and test the connection without the modules in the connection.FigureB‐09. FemaleNULLmodemadapterandpinoutsSerial Loopback AdapterPart Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range testing. During a range test, the serial loopback adapter configures the module to function as a repeater by looping serial data back into the radio for retransmission.FigureB‐10. Serialloopbackadapterandpinouts
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 68AppendixB:DevelopmentGuideUSB Development BoardExternal InterfaceUSB Pin Signals B-11a. I/O & Power LEDsFigureB‐11. FrontView LEDs indicate RF module activity as follows:Yellow (top LED) = Serial Data Out (to host)Green (middle)  = Serial Data In (from host)Red (bottom)  = Power/Association Indicator (Refer to the D5 (DIO5 Configuration) parameter)    B-11b. RSSI LEDsRSSI LEDs indicate the amount of fade margin present in an active wireless link. Fade margin is defined as the difference between the incoming signal strength and the module's receiver sensitivity.3 LEDs ON = Very Strong Signal (> 30 dB fade margin)2 LEDs ON = Strong Signal (> 20 dB fade margin)1 LED ON = Moderate Signal (> 10 dB fade margin)0 LED ON = Weak Signal (< 10 dB fade margin) B-11c. USB PortStandard Type-B OEM connector is used to communicate with OEM host and power the RF module. B-12a. DIP SwitchFigureB‐12. BackView DIP Switch functions are not supported in this release. Future down-loadable firmware versions will support the DIP Switch configurations. B-12b. Reset SwitchThe Reset Switch is used to reset (re-boot) the RF module.TableB‐03. USBsignalsandtheirimplantationsontheXBee/XBee‐PRORFModulePin Name Description Implementation1 VBUS Power Power the RF module2 D- Transmitted & Received Data Transmit data to and from the RF module3 D+ Transmitted & Received Data Transmit data to and from the RF module4 GND Ground Signal GroundB‐11a.I/O&PowerLEDsB‐11b.RSSILEDsB‐11c.USBPortB‐12a.DIPSwitchB‐12a.ResetSwitch
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 69AppendixB:DevelopmentGuideX-CTU SoftwareX-CTU is a MaxStream-provided software program used to interface with and configure Max-Stream RF Modules. The software application is organized into the following four tabs:• PC Settings tab - Setup PC serial ports for interfacing with an RF module• Range Test tab - Test the RF module's range and monitor packets sent and received• Terminal tab - Set and read RF module parameters using AT Commands• Modem Configuration tab - Set and read RF module parametersFigureB‐13. X‐CTUUserInterface(PCSettings,RangeTest,TerminalandModemConfigurationtabs)NOTE: PC Setting values are visible at the bottom of the Range Test, Terminal and Modem Configura-tion tabs. A shortcut for editing PC Setting values is available by clicking on any of the values.InstallationDouble-click the "setup_X-CTU.exe" file and follow prompts of the installation screens. This file is located in the 'software' folder of the MaxStream CD and also under the 'Downloads' section of the following web page: www.maxstream.net/support/downloads.phpSetupSerial Communications SoftwareA terminal program is built into the X-CTU Software. Other terminal programs such as "HyperTer-minal" can also be used to configure modules and monitor communications. When issuing AT Com-mands through a terminal program interface, use the following syntax:FigureB‐14. SyntaxforsendingATCommandsNOTE: To read a parameter value stored in a register, leave the parameter field blank.The example above issues the DL (Destination Address Low) command to change destination address of the module to "0x1F". To save the new value to the module’s non-volatile memory, issue WR (Write) command after modifying parameters.To use the X-CTU software, a module assembly (An RF module mounted to an interface Board) must be connected to a serial port of a PC. NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. The interface data rate and parity settings of the serial port ("PC Settings" tab) must match those of the module (BD (Baud Rate) and NB (Parity) parameters respectively).
©2007MaxStream,Inc. 70AppendixC:AdditionalInformation1-Year WarrantyXBee/XBee-PRO RF Modules from MaxStream, Inc. (the "Product") are warranted against defects in materials and workmanship under normal use, for a period of 1-year from the date of purchase. In the event of a product failure due to materials or workmanship, MaxStream will repair or replace the defective product. For warranty service, return the defective product to MaxStream, shipping prepaid, for prompt repair or replacement.The foregoing sets forth the full extent of MaxStream's warranties regarding the Product. Repair or replacement at MaxStream's option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND MAXSTREAM SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MAXSTREAM, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSE-QUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other rights which vary from state to state may also apply.Ordering InformationFigureC‐01.DivisionsoftheXBee/XBee‐PRORFModulePartNumbersFor example: XBP24-AWI-001 = XBee-PRO OEM RF Module, 2.4 GHz, attached whip antenna, Industrial temper-ature rating, IEEE 802.15.4 standardIf operating in Japan, XBee-PRO RF Modules must contain firmware that limits transmit power output to 10 dBm. For a list of module part numbers approved for use in Japan, contact Max-Stream [call 1-801-765-9885 or send e-mail to sales@maxstream.net].1 2Reserved for internal useInsert the letter‘A’2MaxStream Product FamilyXB24=XBee 2.4 GHzXBP24=XBee-PRO 2.4 GHz15433Antenna OptionC=Chip AntennaU=U.FL RF ConnectorW=Integrated Whip Antenna4RatingI=Industrial (-40 to 85° C)5Protocol001=802.15.4002=ZigBeeA
XBee/XBee‐PRO™OEMRFModules‐802.15.4‐v1.xAx[2007.05.031]©2007MaxStream,Inc. 71AppendixC:AdditionalInformationContact MaxStreamFree and unlimited technical support is included with every MaxStream Radio Modem sold. For the best in wireless data solutions and support, please use the following resources:MaxStream office hours are 8:00 am - 5:00 pm [U.S. Mountain Standard Time]Documentation:  www.maxstream.net/support/downloads.phpTechnical Support:  Phone. (866) 765-9885 toll-free U.S.A. & Canada (801) 765-9885 WorldwideLive Chat.  www.maxstream.net E-Mail. rf-xperts@maxstream.net

Navigation menu