Man and Machine BTK01 Wireless Keyboard User Manual

Man & Machine Inc. Wireless Keyboard

user manual

RRReeeaaallllllyyy   HHHooottt   TTToooooottthhh   KKKeeeyyybbboooaaarrrddd    The Really Hot Tooth is a Bluetooth wireless water-resistant and contaminant free keyboard with full tactile feedback. The sealed and rigid surface is ideal for industrial, marine, and medical use, as well as other applications where moisture, cleaning, and durability are a consideration. Because the Really Cool is also quieter than "standard" keyboards, they are great for applications where noise generated from “key-clicks” is a problem. Really Hot Tooth is based on the wireless Bluetooth HID profile. It can be used with PCs, Laptops, Tablet PCs, PDAs and Smartphones with built in Bluetooth HID profile, or via USB Bluetooth bridge with appropriate driver (Bridge with driver sold separately).   Weight: 817g (1.8 lb.) Dimensions: 381  x140  x 15.3 mm  (15.0”  x 5.5”  x  0.6”) Number of keys: 107  keys US layout  Operating Frequency:  2.4 GHz  Warranty period: One-year limited warranty   System requirements: Built in Bluetooth HID profile or USB interface for wireless bridge with appropriate driver. Power: 3 volts (5 volts to charge) Rechargeable Lithium-ion battery. Charging Cable included. The keyboard turns itself off if it is not used for more than three minutes. KEYBOARD MUST BE CHARGED FOR AT LEAST TWO HOURS BEFORE 1ST USE  Pairing the Really Hot Tooth Keyboard:      For Built in Bluetooth HID PCs, Laptops, Tablet PCs and PDAs: 11..  Turn on the keyboard by pressing the Power Button for two seconds (See the picture on the right). Green light indicates keyboard is on. 22..  Press the Pairing Button on the keyboard to enable keyboard pairing mode. Blue light blinks when the keyboard is in pairing mode.  33..  Open the Bluetooth manager on your PC, Laptop or PDA and follow the instruction for the software to pair the keyboard.  44..  When pairing is complete the blue light stops blinking and it becomes solid green. The keyboard is now ready for use.      Using a USB Bluetooth Bridge: (Bridge with driver sold separately) 11..  Turn on the keyboard by pressing the ON/OFF Button (See the picture on the right). Green light indicates keyboard is on. 22..  Press the Pairing Button on the keyboard to enable keyboard pairing mode. Blue light blinks when the keyboard is in pairing mode. 33..  Connect your USB Bluetooth bridge to the USB port on your PC. 44..  Open the Bluetooth manager software for the bridge and follow the instruction for the software to pair the keyboard.   55..  When pairing is complete the blue light stops blinking and it becomes solid green. The keyboard is now ready for use.  Battery status light: • Red light indicates charging. (Turn keyboard on to check LED status) • Blinking blue light indicates pairing mode. • Green light indicates battery power on.  Cleaning Instructions for Really Hot Tooth Keyboard: • Clean the keyboard surface by wiping, brushing, spraying or dipping it. Use only rags, sponges or soft bristle brushes.  DO NOT SUBMERGED  THEKEYBOARD MINI USB CONNECTOR INTO CLEANING FLUID   • The rubber of Really Hot Tooth can be cleaned with water, soap, alcohol, 10% bleach solutions, and a variety of chemical disinfectants.  DO NOT use Petroleum based cleaners, Acetone, Over 10% bleach solutions, Temperature or pressure sterilization, buffing pads or  scrubbing pads Charging the Really Hot Tooth Keyboard: • Use the Mini USB cable (included) to charge the keyboard.  Plug the USB “A” end to your PC and the mini USB “B” end to the USB Charging port connector on the keyboard shown below. • It takes approximately 2 hours to fully charge the battery.   THESE INSTRUCTIONS AND RECOMMENDATIONS HAVE BEEN PREPARED TO ADVISE THE PROPER METHODS FOR CLEANING YOUR PRODUCT. MAN & MACHINE, INC. OR THE LOCAL DISTRIBUTOR CANNOT ASSUME ANY RESPONSIBILITY FOR THE APPLICATION OF THEM. IF THERE ARE ANY QUESTIONS, PLEASE CONTACT PLACE OF PURCHASE OR MMI PRIOR TO CLEANING. MAN & MACHINE DOES NOT CONSIDER THE REALLY HOT TOOTH KEYBOARD TO BE A MEDICAL KEYBOARD FOR INFECTION CONTROL PURPOSES DUE TO THE INABILITY TO MECHANICALLY CLEAN ALL SURFACES AND AREAS ON THE KEYBOARD. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.  You can email us at: info@mmimd.com  or call us at: (301) 341-4900 In Europe, contact +31-23-5450185 www.man-machine.com  Copyright Man & Machine, Inc. 2008
FCC STATEMENT   1. This device complies with Part 15 of the FCC Rules.      Operation is subject to the following two conditions:        (1) This device may not cause harmful interference, and        (2) This device must accept any interference received, including interference that may cause              undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance      could void the user's authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a             Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are             designed to provide reasonable protection against harmful interference in a             residential installation. This equipment generates, uses and can radiate radio             frequency energy and, if not installed and used in accordance with the             instructions, may cause harmful interference to radio communications. However,             there is no guarantee that interference will not occur in a particular installation.             If this equipment does cause harmful interference to radio or television reception,             which can be determined by turning the equipment off and on, the user is             encouraged to try to correct the interference by one or more of the following             measures:               -- Reorient or relocate the receiving antenna.               -- Increase the separation between the equipment and receiver.               -- Connect the equipment into an outlet on a circuit different                   from that to which the receiver is connected.               -- Consult the dealer or an experienced radio/TV technician for help.        FCC ID: X5DBTK01   RF WARNING  STATEMENT                  The device has been  evaluated to meet general RF exposure requirement.                  The device can be used in portable exposure condition without restiction.

Navigation menu