MARS TOHKEN SOLUTION THIR-6000B Handheld Image Reader(Linear/2D Scanner) User Manual

TOHKEN CO., LTD. Handheld Image Reader(Linear/2D Scanner)

Contents

User manual 2 of 2

  154.  Communications                  •  Bar Code Data Transmission: The unit transmits the scanned data to the host computer.  •  Command Signal Receipt: The host computer transmits the command signals to the unit and sets up the operation of the unit.  •  Image Data Transmission: The unit transmits the captured image data to the host computer.  Refer the section 5.5 for the communication parameter conditions.   4.1 Data Transaction  Data transaction setup should be accomplished with sending command from host computer. Asynchronous protocol is used for barcode data transmission and serial commands transmission.    4.2 Image Data Transaction  The communication protocol utilizes XMODEM (SUM128) in the case of the image data output.  The host side computer should be provided with the software to receive the transmitted data.    The receiving unit should also be kept “ready” before receiving the data.
  16 5. Specifications  5.1 General specifications  Type  THIR-6000(H) Dimensions       159(H)×63(W)×99(D)mm Weight       Approx. 220 g (including the battery) Illumination  1.  White LED (THIR-6000B, THIR-6000HB) 2. Red LED (THIR-6000DM-B) Aiming beam       Red LED (peak wave length is 644nm) Indicator       Monitoring LED (3 colors), Vibration Image sensor       CMOS color area sensor (1.3M pixel) Minimum resolution 1.  0.125mm (1D barcode), 0.19mm (2D barcode) (THIR-6000B) 2.  0.1mm (1D barcode), 0.167mm (2D barcode) (THIR-6000HB, THIR-6000DM-B) Supported barcodes (1D)       Code39, Code128, EAN128, Codabar, ITF,       JAN/EAN/UPC, RSS, Code93 Supported barcodes (2D)       Data Matrix (ECC200), QR Code, Micro QR Code       PDF417, MicroPDF, MaxiCode, Composite      Postal code Format       ASCII or Bitmap(image) Bluetooth interface       Bluetooth 2.0 Class1      *can be worked with Windows 2000/XP Battery       Li-ion rechargeable battery (3.7V, 2200mAh) Operating time       7 hours  (calculated with 5 seconds per 1 barcode reading) Charging time       3 hours Environmental specifications   Operational Temperature       0 to 40 degrees centigrade Storage Temperature       - 20 to 60 degrees centigrade Operational Humidity       35 to 85 %RH (Non-condensing) Storage Humidity       35 to 85 %RH(Non-condensing) Vibration       10 to 55 Hz(max. 4G) Shock       Durable multiple drops to concrete from 7ft.
  175.2 Functional specification  Reading Direction  ・PITCH   :±35 degree  ・SKEW   :±35 degree  ・TILT   :360 degree  ・Ambient Light  :0 to 10,000 lx    Viewing angle
  185.3 Reading Range/Depth  Decodable Symbols  Liner:  Code39, Code128, EAN128, Codabar, ITF, JAN / EAN / UPC, RSS  Check digit calculation method: Code39   Modulus 43 Codabar   Modulus 16 ITF  Modulus 10  2-D:   Data Matrix(ECC200),QR Code, Micro QR Code,PDF417, Micro PDF, Maxi Code, Composite  Reading Digit: (Except ITF)   1∼2047 (Only ITF)     2,4,6∼2047
  19 •  Reading Range (Normal type)                              unit:mm  •  Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. •  Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew.  about 34°Distance from scanner Vertical Horizontal 1D(0.125) 70∼1101D(0.15) 60∼1301D(0.25) 40∼1601D(0.33) 40∼1802D(0.25) 60∼1302D(0.33) 50∼16026 33 6650 75 95 50 100150about 27°2D(0.19) 80∼110
  20 •  Reading Range (High density type)                              unit:mm  •  Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. •  Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew.  Distance from scanner Vertical Horizontal 1D(0.1) 40 to 70 1D(0.125) 40 to 752D(0.19) 40 to 7526 33 6650 75 95 50 100150about 27°about 34°2D(0.167) 40 to 70
  21 •  Reading Range (DM type)                             unit:mm  •  Reading ability depends on environment (brightness etc) and the printing quality of scanned barcodes. •  Measured in 500 to 1000(lx) of homogeneous brightness, printed with good quality, no pitch and no skew.   Distance from scanner Vertical Horizontal 1D(0.1) 40 to 70 1D(0.125) 40 to 752D(0.19) 40 to 7526 33 6650 75 95 50 100150about 27°about 34°2D(0.167) 40 to 70
  225.4 Default settings When the unit is shipped from the factory, the initial setup is as follows:  ・ THIR-6000B, THIR-6000HB Æ Enabled Symbols: all symbols. ・ THIR-6000DM-B Æ Data Matrix (ECC200) and QR Code  Security settings As the default, security settings are not configured.    Please see “7.4 How to configure security setting”.
  236. Dimensions 6.1Housing Dimensions                                Unit: mm 63  99 159
  247. Specialty Function 7.1 Global Shutter Cropping is a method to remove unwanted areas from the image to make the image small. Following is the procedure to set up this function through the serial interface.  Confirming the cropping status   Serial Command ?IMG<cr> << Example of reply>>             【 Setting for Serial Command CAPX=m, CAPY=n (m,n=0,1,2,3) << Value >>   ******** STATUS ******** THIR-6000  BBC=0  0:256 1:16 2:RLE 3:AVE 4:AVERLE 9:Color  IMODE=0  PX=0  PY=0  WX=1280  WY=1024  CAPMODE=0,0,1280,1024  CAPX=0 ( 0:100%, 1:75%, 2:50%, 3:25% )  CAPY=0 ( 0:100%, 1:75%, 2:50%, 3:25% )  VMODE=0 (0:Mono 1:Color ) ********* END ********** THIR-6000 System version = K85C-V1.0c Decode version = K85A-V1.0c Bolded is status of cropping. 0…100% 1…75% 2…50% 3…25%
  25Cropping  ・・・CAPX=0、CAPY=0   ・・・CAPX=2、CAPY=1     25%50%75% 100%25% 50%75%100%
  267.2 Auto detection mode 7.2.1 Overview By using this mode, THIR-6000 can read and decode symbols automatically. THIR-6000 detects changes of image in its field of view, like change of environmental brightness, motion of objects.    When there is such a change, THIR-6000 starts to capture an image and tries to decode.  This function is designed for stand mounting use to read documents with printed barcodes.  For example, it is suitable for using on the counter at post office.  CAUTION With Auto Detection mode, trigging switch does not work. Plus, neither does capturing an image, receiving a Hex program and executing a Macro program. Please turn Auto Detection mode OFF if those function are needed to be used. Auto Detection mode may not work well under the too high, too low or unstable brightness.                     Field of view Object with barcode Note • Auto Detection mode is not a default setting.  Please have THIR-6000 read the corresponding configuration barcode to change to Auto Detection mode. •  THIR-6000 does not vibrate when it decodes a symbol successfully with Auto Detection mode regardless of current setting of the vibration.
  277.2.2 How to use To put the THIR-6000 in the auto detection mode, please follow one of the following methods: -  Send the serial command "LFMODE=1<CR>" to the scanner. -  Read the corresponding barcode from the configuration barcode set.  To exit the auto detection mode, please follow one of the following methods: -  Send the serial command "LFMODE=0<CR>" to the scanner. -  Read the corresponding barcode from the configuration barcode set.  The serial command "?LF<CR>" to check which mode the scanner is available.  For the details of how to work Auto Detection mode, please see the following figures, flow chart and timing chart.
  28The flow chart of Auto Detection mode  StandbyLabel in Detected?Decoded?Monitor LED: GreenBuzzer : beep 1 timeMonitor LED: OrangeAiming beam: BlinkingVerifyCompare decoded data with last decode data.Monitor LED: RedBuzzer : beep 2 timesTry to decodeWithin decoding time limit?No: TimeoutMake an object with barcodes go into THIR-6000’s field of view YesYesDifferent data Same dataNoYesLabel out Detected? Within detection ignored limit?NoNo: TimeoutYesOut put the decoded dataYesStandbyLabel in Detected?Decoded?Monitor LED: GreenBuzzer : beep 1 timeMonitor LED: OrangeAiming beam: BlinkingVerifyCompare decoded data with last decode data.Monitor LED: RedBuzzer : beep 2 timesTry to decodeWithin decoding time limit?No: TimeoutMake an object with barcodes go into THIR-6000’s field of view YesYesDifferent data Same dataNoYesLabel out Detected? Within detection ignored limit?NoNo: TimeoutYesOut put the decoded dataYes
  29Timing chart  7.3 For high density barcodes  HD mode is designed to read high density barcodes (under 0.167mm of small element size) more quickly.   Since this is not a default setting, please change to HD mode by reading the corresponding configuration barcode.  7.4 How to configure security settings  Serial command ?    Show status data string1     If the data is correctly received, THIR-6000B is connected to the host computer.   PIN CODE=XXXX  Put 4 digit numeric to “XXXX”.     Bluetooth connection will be disconnected when PIN CODE is set.    Please enter the PIN CODE to connect again.    If set PIN CODE as “0000”, there is no security.  WSETS    Write settings to THIR-6000’s flash memory (make sure the connection is established) When THIR detects a label goes out from FOV or the detection ignored time is passed, this signal turns OFF. This signal is kept ON until THIR decodes successfully (including discarding the decoded) or the decoding time limit is not passed.) ...Label in detection  ON OFF Decoding  ON OFF Label out detection OFF ON ......When THIR detects a label is coming in, this signal turns OFF
  307.5 How to confirm data transmitting To make sure the connection is established, the following method is strongly recommended. It will take approx. 20 second to detect disconnection between THIR-6000 and the host computer caused.  The data tried to be sent to the host during this 20 second will be lost.  By using the following method, operator can know if the data is correctly transmitted or not.  THIR-6000B waits response from the host after it sends data. This period can be configured as limit time.    If THIR-6000B does not receive response from the host, THIR-6000B judges the data has been lost.  To complete this function, the host has to have the function to send “received” or ACK (0x06) to THIR-6000B if it receives data from the scanner.  (1). Normal flow           (2)In case of NG           HOST    Received or ACK BCR  Trigger ON Read/Decode Data transmit  Buzzer beeps Vibration Reading dataHOST    Received or ACK  BCR  Trigger ON Read/Decode Data transmit  After time out LED ON Buzzer beeps Reading data
  31•  How to switch confirmation ON ÅÆ OFF 1). Configuration barcode menu (Other document)  Æ By reading barcodes 2). By sending serial command      ANSWERBACK=X  Confirmation ON/OFF       0: OFF (Default) 1: ON      ANSWERBACKTIM=X  Time out limit  1∼3 second (Default:1)  •  How it works THIR-6000B waits response from the host within the time our limit. During the time out limit, trigger signal and other serial command are not valid. After getting response from the host or passing the time out limit, trigger signal and other serial command become valid.  •  How to indicate 1). Get response from the host  Æ Buzzer and vibrator indicate OK 2). No response from the host  Æ Buzzer and red LED indicate NG   Buzzer  LED Vibration OK  2 times (high tone)    non  100msec NG   3 times (low tone)  Red LED ON (700msec) non
  327.6 Image preprocessing Article Command  Contents Image Preprocessing  ?PROC  Indicates the status of a image pre-processing setting contents  IPFUNC0=a1,a2,a3,a4,a5 No.0 Image Preprocessing Setting   FILTER33[ I ] [ j ]=a  Set coefficient value of 3x3 mask filter.   (i, j=0 through 2, a= -99 through +99) 3x3 Mask Filter  FILTER33DM=1-10000  Set magnification value of 3x3 mask filter. FILTER55[ I ] [ j ]=a  Set coefficient value of 5x5 mask filter.   (i, j=0 through 2, a= -99 through +99) 5x5 Mask Filter  FILTER55DM=1-10000  Set magnification value of 5x5 mask filter.  Article   Command  Description  None    0  No Image preprocessing Black Erosion  1  Erosion 2x2  3 Erosion 3x3  5 Erosion 5x5   7  Erosion 2x1 (w)   9  Erosion 1x2 (h) White Dilation  2  Dilation 2x2  4 Dilation 3x3  6 Dilation 5x5   8  Dilation 2x1 (w)   10  Dilation 1x2 (h) Reverse  20  Reverse White & Black Contrast   21  Cont (L12cut): Cut the rest (from the darkest) 12.5% Enhancement 22  Cont (L22cut): Cut the rest (from the darkest) 25%  23 Cont (H23cut): Cut the most (from the brightest) 12.5% 21&22 are used to enhance black  24  Cont (H24cut): Cut the most (from the brightest) 25% 23&24 are used to enhance white  25  Cont (LH12cut): Cut the rest 12.5% and the most 12.5%.  26 Cont (LH22cut): Cut the rest 25% and the most 25%. Gamma Correction 27 Gamma(r=0.5) Execution for Gamma Correction 0.5 Smoothing Filter  40  Low pass Filter 3x3 average value Median  41  Median filter 3x3 median value 3x3 Filter  60  3x3 filter FILTER33, FILTER33DM execution filtering by command 5x5 Filter  61  5x5 filter FILTER55, FILTER55DM execution filtering by command Down Size  70  Down Size (Quick)  Down size whole image with quick mode Down Size  71  Down Size (Average) Down size whole image with average speed mode Please ask our sales department for more information.
  338. Troubleshooting 8.1 The unit does not work while pushing the read trigger switch.  Does the battery have enough amounts? If the battery’s voltage is not enough, THIR-6000B may not operate correctly. Please see “2.1 Charging battery”.  8.2 Can not charge battery   Is THIR-6000B placed on the cradle correctly? If THIR-6000B is not placed on the cradle correctly, charging battery may be failed.  Please see “2.1 Charging battery”.  Is the AC adapter inserted correctly? If the AC adapter inserted correctly to the cradle, charging battery may be failed.  Is power supply polarity correct? When it is connected with reverse polarity, charging battery is failed. Correct polarity Æ    Is the power rating of the power supply enough? Unless the power supply capacity is enough, charging battery is failed.    Is the charging terminal clean? If there is dirt/dust on the charging terminal, charging battery may be failed.    Isn’t the battery too old? The rechargeable battery does not last forever.  If a change in the battery life is noticed, it is probably time to purchase a new battery.  Criterias to know the time to change the battery are 300 times of charging/discharging or 2 years of usage under proper environmental condition.  Please contact our sales department about alternative battery.
  348.3 Barcode Cannot be Read.  Is there beep from the buzzer when THIR-6000B reads barcode?   YES  Æ Barcode is decoded, but an error is occurred during transmitting data through Bluetooth.  Please see “8.4. Errors in transmitting data”. NOÆ Barcode is not decoded.    Please see the following instruction to decode barcode correctly.  Is a code setup correct?   Check the settings of the reader and that the 2D code is enabled  Is reading distance suitable?   Reading may be impossible when the reading distance is outside the working range of reading depth. Moreover the printing quality of the code may make it non-readable even if it is within the reading range limits.   Is the surface of the code glossy?   If the surface of the code is glossy, the illumination will be sometimes reflected like a mirror. To avoid this, put the scanner in angle relative to the symbol.  Is the reading window clean?   If the window becomes dirty or stained, the image taken by the reader might not be good enough for reading. Clean with a lens cleaner or similar anti-scratching (non-abrasive) method.    Is the print quality of the code good?   Please check whether print quality of the cells, code size, etc. conforms to the standard.
  35     8.4 Reading data gets garbled Do you set fixed digit for ITF In some cases, cancellation of significant digits (reading it through with a few digits than a printed digits) in ITF(Interleaved 2 of 5) might be used. We recommend setting specific digit of ITF.  8.5 Bluetooth connection is disconnected Is THIR-6000B in the range or Bluetooth connection? The Bluetooth unit of THIR-6000B allows staying away 10m from the Bluetooth adapter.  But the distance is varied depending on conditions.    Please check the strength of wave if it seems to be weak.   In the utility screen of the driver, the strength can be checked.   If it is weak, please use TMU-6000 to receive wave more efficiently.      8.6 Reading data is missed partially during transmitting Is the connection disconnected during transmitting? Reading data can be missed partially if the connection is failed during the transmitting.   Please check connectivity as explained “2.2 Setting up the host computer”.
  368.7 Keyboard wedge interface is needed If keyboard wedge software is installed to the host computer, THIR-6000B can be used as keyboard interface device.    Please let our sales department know if keyboard wedge is needed.  8.8 PIN CODE is required when Bluetooth connection is established PIN CODE is not set at the time or shipment from our factory.  To initialize PIN CODE, please use “Default setting” barcode in “Configuration Barcode Menu”.   If PIN CODE is needed to be set, please see “7.4. How to configure security settings”.
  37Appendix 1 Cradle(TBC-6000) 1.  Overview    Cradle for THIR-6000B series 2. Specification Dimensions  :72(H)×90(W)×241(D) Weight   :Approx. 215g (AC adapter, wireless unit, and THIR-6000B are not included) Tapped Hole  :φ5 x 3 Screw   :M4×M20    2pcs (come with the cradle) 3. Outlook                             AC adapter jackSlit Cable clamperRearHook the cable of AC adapter Charging terminator Tapped holeHook Edge Fix the metal plate ※Please use one of the two tapped hole for charging terminator side.
  39  [Memorandum] Warranty Obligations Exclusive of the cases with special mentions in quotations, contracts or specifications, TOHKEN warrants this products as the following.  1.  Term of warranty One year from the date of purchase. 2. Warranty Coverage TOHKEN will repair or replace the product at no charge if the reasons of defects are come from our responsibility. The losses caused by the defect of this product are not covered. If the reasons of defects are the following, they are not covered by this warranty.     (1). If the product is not used in accordance with all operation instructions. (2). If the product is modified by outsiders of TOHKEN. (3). If the defects are not caused by the product itself. (4). If the defects are caused by fire, pollution, abnormal voltage, or natural disasters, such as earthquake, thunderstorm or flood. 3.  Usage outside of Japan This warranty coverage is based on the usage in Japan.  Please contact our sales department if there need to use this product ourside of Japan.
  40
  41              TOHKEN CO., LTD Head quarters 2-7-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo Japan 163-0710   Sales   03-5325-4311 to 4315    Sales Promotion 03-5325-4322  Nagoya office    4-2-12 Meieki, Nakamura-ku, Nagoya Japan 450-0002   Sales   052-565-9091  Osaka office 2-9-1 Higashi-Tenman, Kita-ku, Osaka Japan 530-0044   Sales   06-6353-5476  Fukuoka office 8-36 Hakata-eki Chuogai, Hakata-ku, Fukuoka Japan 812-0012   Sales   092-441-3638  Hitachi office 2-1-10 Hashikabe, Hitachinaka, Ibaragi Japan 312-054   Sales   029-276-9555  Field support department (Technical Center 3) 1-43-2 Tamagawa, Chofu, Tokyo Japan 182-0025   Field support  042-484-5190

Navigation menu