Lutron Electronics 0114 Wireless Dimmer Switch User Manual 0301815a

Lutron Electronics Company Inc Wireless Dimmer Switch 0301815a

Contents

0301815a Instruction sheet

NightlightDayEveningOffInstallation InstructionsPlease Read Before InstallingP/N 0301815 Rev AGRAFIK TTMLutron Electronics Co., Inc.7200 Suter Road, Coopersburg, PA 18036-1299  USA120 V~  50 / 60 Hz6a1  GRAFIK TTM -GH2B, -GH4B, -GH5B, and -GH6B models can control power boosters / load interfaces if neutral is used. See Lutron®  P / N  369971 and 369985, Compatible Power Boosters and Load Interfaces.2   RRT- models are RadioRA® 2 compatible and HQRT- models are HomeWorks® QS compatible.3   Not for use with receptacles or appliances (e.g., garbage disposals). See Lutron® Application Note #109 for compatibility with dimmed receptacles. 4  Magnetic Low-Voltage Applications: Use with halogen-based lamps only. 5  UL® listed for use with dimmable ELV transformers, but not recommended because Lutron does not do system performance testing. 6   Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following:•  Do not operate low-voltage circuits without operative lamps in place.•  Replace burned-out lamps as soon as possible.•  Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent.7   When using the hybrid keypad to control MLV halogen-based xtures, the maximum lamp wattage is determined by the efciency of the transformer, with 70%–85% as typical. For actual transformer efciency, contact either the xture or transformer manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the hybrid keypad.8   Ten (10) driver maximum.9  Includes Lutron® Hi-lume® 1% 2-wire LED drivers, Mark XTM, Tu-Wire®, and POWERSENSE®.10  Neutral is required for Mark XTM, Tu-Wire®, and POWERSENSE®. EnglishSingle-pole – Switch will be replaced by a GRAFIK TTM hybrid keypad. Connect the Green ground wire on the hybrid keypad to the Green or bare ground wire in the wallbox (See Important Notes, number 3).Connect the Black wire on the hybrid keypad to one of the wires removed from the switch. If you had taped together two wires (see step4), connect both wires to the Black wire on the hybrid keypad and remove the tape.Connect the Red wire on the hybrid keypad to the other wire removed from the switch.Connect the White wire on the hybrid keypad to the neutral wire in the wallbox  (See Important Notes, number 7). The switch may have two wires attached to the same screw. Tape these two wires together before disconnecting. Proceed to disconnect the wires from the switch. Remove wallplate from the GRAFIK TTM hybrid keypad and any companion device but leave wallplate adapter connected.Install GRAFIK TTM control.Identify switch type. Single-pole – The switch will have insulated wires connected to two screws of the same color plus a green ground screw.Multi-location – 3-way switches will have insulated wires connected to three screws plus a green ground screw. One of the wires is connected to a screw of a different color (not green) or labeled COMMON. Tag this wire. GroundRemove wallplate and the switch mounting screws. Leaving all wires attached, carefully pull the switch out from the wall.1Turn OFF power at circuit breaker.IMPORTANT NOTICE: FASSTM – Front Accessible Service SwitchTo replace lamp(s), power may be conveniently removed by pulling the FASSTM down on the hybrid keypad. After replacing lamp(s), push the FASSTM back up fully to restore power to the hybrid keypad. For any procedure, other than routine lamp replacement, power must be turned OFF at the main electrical panel.IMPORTANT Wire connectors provided are for copper wires only. For aluminumwires, consult an electrician. Hybrid Keypad 1,2,3LED Incandescent /  HalogenMLV 4,5,6,7 Halogen Dimmable Electronic  Ballast or Driver 8,9,10RRT-GH2BRRT-GH4BRRT-GH5BRRT-GH6BHQRT-GH2BHQRT-GH4BHQRT-GH5BHQRT-GH6B250 W600 W (Not ganged) 500 W (End of gang) 400 W (Middle of gang)400 VA  (300 W)3.3 A  (400 VA)Companion DeviceConnect the Green wire on the companion device to the Green or bare ground wire in the wallbox (See Important Notes, number 3).Connect the Red wire on the companion device to the tagged wire and to the same color wire connected to the Red wire on the hybrid keypad .Connect the Blue wire on the companion device to the remaining wire. Installation2Operation3456FASSTM :   Front Accessible Service SwitchNote: FASSTM is not available on companion devices.Customer Assistance: www.lutron.com U.S.A. | Canada | Caribbean:  1.844.LUTRON1   |   Mexico: +1.888.235.2910   |   Others: +1.610.282.3800 • For warranty details, please visit: www.lutron.com/TechnicalDocumentLibrary/warranty.pdf  |  For FCC/IC information, please visit: www.lutron.com/fcc-icLutron, C•L, Hi-lume, and Tu-Wire are registered trademarks and FASS, and GRAFIK T are trademarks of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. POWERSENSE is a registered trademark of Osram Sylvania, Inc. Mark X is a registered trademark of Philips Lighting Electronics N.A., Inc. © 2014-2015 Lutron Electronics Co., Inc.GroundDifferent-colored screwTag/Common Companion devicesRT-GRDW For use with RRT– hybrid keypads, dimmers and switches (0.1 A)HQT-GRDW For use with HQRT– hybrid keypads, dimmers and switches (0.1 A)!  WARNING! Shock Hazard. May result in serious injury or death. Turn off power atcircuit breaker before installing the unit.SymptomPossible Solutions1.  Lamp and light bar LEDs do not turn on.•  Push FASSTM up to restore power.• Turn ON breaker.• Replace burned out lamp(s).•  Check hybrid keypad wiring (See Installation).•  Cycle power to unit by pulling the FASSTM down and back up to fully restore power. If unit beeps see Symptom 2.2.  Unit beeps after power cycle.•  Check wiring. If neutral wire is connected, ensure that the Black wire is connected to Live and the Red wire is connected to Load.•  Check wiring. Ensure that the Blue and Red wires are connected as specified in Installation. 3.  Lamps turn On and hybrid keypad works but companion devicedoes not work.•  Ensure that the wire connected to the Blue (or Red) wire on the hybrid keypad is the same as that connected to the Blue (or Red) wire on the companion device (See Installation Step 6b).4.  Lamps repeatedly turn On and Off. •  See Minimum Load and ensure the acceptable minimum load is met.5.  Lamps icker or exhibitpoor dimming range.•  Set low-end trim. See Installation Step 9 for details. •  See Recommended LEDs.6. Wallplate is warm.•  Solid-state hybrid keypads internally dissipate about 1% of the totalconnected load. It is normal for hybrid keypads to feel warm to the touch during operation.8.  Lamps don’t turnOn / Off  from  akeypad.•  Improper programming. Programming must be done through the system software. •  Out of RF range. Reposition to be within 30 ft (9 m) of an RF signal repeater.•  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. •  Wiring error. Ensure wiring matches installation instructions and appropriatewiring diagram.9.  All LEDs on the hybrid keypad ash whenany button is pressed.•  The hybrid keypad is in factory settings mode and has not been congured to work in a system. Follow the steps in the System SetupGuide to program.TroubleshootingHybrid Keypad Line-Side (with or without neutral wire) 1IMPORTANT Cut the blue wire at the insulation and cap with the yellow connector. Multi-location – Lamps can be controlled from multiple locations.One location will be replaced by a GRAFIK TTM hybrid keypad and the other location(s) by a  GRAFIK TTM companion device. If the neutral wire is not being used, the hybrid keypad can be wired on the line-side or the load-side. If using the neutral wire, the hybrid keypad must be wired on the line-side.6bHybrid KeypadConnect the Green ground wire on the hybrid keypad  to the Green or bare ground wire in the wallbox (See Important Notes, number 3).Connect the Black wire on the hybrid keypad  to the tagged wire removed from the switch. Connect the Red wire on the hybrid keypad to one of the remaining wires.Connect the Blue wire on the hybrid keypad to the remaining wire.Connect the White wire on the hybrid keypad to the neutral wire in the wallbox (See Important Notes, number 7).120 V~60 HzBlack GroundRedBlueGreenNeutralLine / HotLoadWhiteConnect if using neutral wire Uncommissioned Behavior• Top button toggles local load On/Off•All other buttons utter to indicateuncommissioned status Flexible Control•  Press to activate a scene or zone• Buttons provide scene / zone status• Buttons are fully programmable1.  CAUTION: To avoid overheating and possible damage to other equipment, do not use hybrid keypads to control receptacles or motor-operated appliances.2.  Install in accordance with all national and local electrical codes.3.  When no “grounding means” exist in wallbox, the NEC® allows control without a groundingconnection to be installed as a replacement if 1) a non-metallic, noncombustible faceplateis used with nonmetallic attachment screws or 2) the circuit is protected by a ground faultcircuit interrupter (GFCI). For this type of installation, cap or remove the green ground wireon the hybrid keypad, and only use a Lutron® GRAFIK TTM wallplate.4.  GRAFIK TTM controls are not compatible with standard 3-way switches. Use only with GRAFIKTTM companion devices.5.  GRAFIK TTM Companion devices cannot be used individually but must be used in conjunctionwith a GRAFIK TTM hybrid keypad in a multi-location application.6.  In any multi-location circuit, use only one GRAFIK TTM hybrid keypad with up to fourGRAFIKTTM companion devices.7.  Neutral wire connection is optional for GRAFIK TTM hybrid keypad; however, the bestdimming performance will be obtained when the neutral wire is connected. Always cap thewhite wire if a neutral wire is not present in wallbox.8.  Return to Factory Settings (Note: Returning a control to the factory settings will remove itfrom the system and erase all programming).Step 1: Triple tap any button on a control. DO NOT release after the third tap.Step 2:  Keep the button pressed on the third tap (for approximately 3 seconds) until theLEDs on the control start to scroll up and down quickly.Step 3:  Release the button and immediately triple tap the button again. The LEDs on the control will scroll up and down slowly. Factory settings have been restored.Important NotesIf dimming LED bulbs, they must be Lutron® compatible! For current compatibility and performance information visit www.lutron.com/LED.Recommended LEDsLoad TypeApplication Number of Companion Devices LED 1, 2 Incandescent / Halogen 3Single-pole 0 3 LED lamps 80 WMulti-location1 4 LED lamps 120 W2 5 LED lamps 160 W3 6 LED lamps 200 W4 7 LED lamps 240 WMinimum Load: 1 See Recommended LEDs.2  If using neutral wire, the minimum load required is one LED lamp or Lutron® Hi-lume® 1% 2-wire LED driver.3  If using neutral wire, the minimum incandescent/halogen load required is 5 W.Hybrid Keypad Load-Side (without neutral wire only) 1Live GroundBlack Red Blue White Green Blue Red Green GroundLoad Neutral  2Tag/Common Hybrid Keypad  Companion device(s)Tag/Common Line / Hot Neutral 1(Connect if using  neutral wire)Black Red Blue White Blue Red Green Green GroundGroundLoad  2Neutral Hybrid Keypad Companion device(s)Tag/Common Tag/Common 1  Neutral wire connection is optional for GRAFIK TTM hybrid keypads; however, the best dimming performance will be obtained when neutral wire is connected.  2  The companion device is wired differently than a standard 3-way switch. Both the Red wire and the tagged wire are connected to the same traveler wire. Turn ON power at circuit breaker.8If desired, consider adjusting low-end and high-end trim by using the RadioRA® 2 or HomeWorks® QS GUI software. 9Carefully push wires into the wallbox. Install controls and snap on wallplate. 7Model NumbersDBM:  Dynamic Backlight Management SensorNote: DBM should be mounted with an unobstructed, clear view of the floor. DO NOT paint or plaster over sensor.

Navigation menu