Lutron Electronics 0068 RF Daylight Sensor User Manual Uesr Manual

Lutron Electronics Company Inc RF Daylight Sensor Uesr Manual

Uesr Manual

123456To remove the bracket from the ceiling, grasp the removal tab on the adhesive strip and pull the tab VERY SLOWLY straight across the ceiling, stretching the strip until the bracket releases from the ceiling.  Discard the strip.  NEVER pull the strip at an angle, as it may break or damage the ceiling surface.Identify a location for the Sensor (see section C. Sensor Placement).Remove the black “wall side” liner from the adhesive strip. Position the mounting bracket on the ceiling and press  firmly for several seconds.Attach the Sensor to the mounting bracket. Perform the Calibration and Test the Sensor as described in section E. Calibration and F. Testing the Daylight Sensor.If the Sensor does not perform satisfactorily from this location, it may be moved to another location by pulling the Sensor straight down and repeating steps 2.1  – 2.7.If the Sensor’s performance is satisfactory, it should be permanently attached to the ceiling tile, as described in section H. Permanent Mounting Methods.Testing the Daylight SensorBefore testing, ensure power to the lighting circuit is ON and the lighting control system is setup and calibrated properly.The lighting circuit should be energized only when all wiring is complete and all persons are clear of fixtures/devices. Turn power ON only after checking that it is safe to do so.Activate Test mode by pressing the “Test” button on the  front of the Sensor. The lens will flash indicating that the  mode was entered.Select all Dimmers or Electronic Switches that you  want to test by pressing the tap button.Cover the Sensor – the system should increase/switch on the lights in the roomShine light on the Sensor – the system should decrease/switch off the lights in the roomWith the lights on, do nothing to the Sensor – If the lights in the room cycle on and off, there is too much feedback from the lights – consider moving Sensor away from lights or re-calibrate the system (see section E. Calibration).Exit Test mode by pressing the “Test” button again.Sensor PlacementDetermine the Daylight Sensor Mounting Location using the diagrams below:•   The arrow on the daylight sensor points toward the area viewed by the sensor.•   Place the daylight sensor so its viewing area is centered on the nearest window at a distance from the window of one and two times the effective window height (H).•    The effective window height (H) starts at the window sill or 3 ft (1 m) up from the floor, whichever is higher, and ends at the top of the window.•   Ensure that the view of the daylight sensor is not obstructed.•   Do not position the daylight sensor in the well of a skylight or above indirect lighting fixtures.•   For narrow areas where the daylight sensor cannot be placed 1-2 (H) from windows, place sensor near windows facing into the space.Temporary Mounting MethodsIf you are uncertain about correctly positioning the Sensor, the following temporary mounting and testing procedures are recommended to verify proper performance before permanently installing the Sensor.Temporary Drop Ceiling Mounting  Use this procedure if the Sensor will be mounted on a ceiling tile.The ceiling tile mounting wire is provided for both temporary and permanent mounting of the Sensor to drop ceilings composed of multiple tiles.  It is designed to allow temporary mounting, testing, and repositioning (if necessary) of the Sensor without damaging a ceiling tile.  Once the Sensor’s final position has been chosen, the mounting wire can be twisted to lock the Sensor in place permanently.   Remove the mounting bracket from the base of the Sensor. Insert the ceiling tile mounting wire through the two smaller  holes in the mounting bracket and replace the mounting bracket. Mount Sensor to a ceiling tile by inserting the wire legs through the tile making sure the Sensor is flush to the tile.Perform the Calibration and Test the Sensor as described in sections E. Calibration and F. Testing the Daylight Sensor.If the Sensor does not perform satisfactorily from this location, it may be moved to another location by pulling the Sensor straight down and repeating steps 1.3 and 1.4.If the Sensor’s performance is satisfactory, it should be permanently attached to the ceiling tile, as described in section H. Permanent Mounting Methods.AInstallationThe Sensor installation procedure is outlined below. Please follow these steps to ensure the Sensor will perform as intended:A.  Pre-Installation  F.   Testing the Daylight SensorB.  Set-Up  G.  Tuning the SystemC.  Sensor Placement  and Coverage  H.  Permanent Mounting MethodsD.  Temporary Mounting Methods  E.  Calibration   Pre-InstallationBefore setting up the Sensor, the corresponding dimming or switching device(s) should  be installed. Refer to that product’s installation sheet for instructions.Pull and remove mounting bracket to insert battery with the negative (–) side up.Set-UpIn order for the Sensor to operate properly, it must first be set up with a corresponding dimming or switching device.  The procedure for setting up a Sensor with a Maestro Wireless® (MRF2- only) Dimmer or Electronic Switch is detailed below.  If setting up a Sensor with a different device, visit www.lutron.com/occsensors or consult the installation guide for that device for the correct set-up procedure.Setting up a Sensor with a Maestro Wireless Dimmer or Electronic SwitchPlace the Dimmer or Electronic Switch in set-up mode  by pressing and holding the tap button for approximately  6 seconds until all LEDs on the device begin flashing.  Release the tap button.Add the Sensor to the Dimmer or Electronic Switch by pressing and holding the “Link” button on the front of the Sensor for approximately 6 seconds until the lens flashes briefly.  The lights in the room will also flash 3 times, indicating the Sensor has been successfully added. The Dimmer or Electronic Switch will exit set-up mode automatically. CKey Features· Easy Installation. No wiring required.·  Easy Set-Up. Default settings are ideal for most situations. Simple and intuitive adjustments available.·   Low Maintenance. 10-year battery life. Convenient low-battery indicator.·  Daylight Dimming and Switching. Sensors integrate with various Lutron® Dimmers and Switches. ·  Ceiling-Mounted Style. ·  Multiple Devices. Each Sensor may be added to up to 10 receiving devices. Sensor OperationDimming – The lights must be manually turned on at the dimming device. The Sensor will automatically decrease the electrical light as daylight increases, and vice versa.Switching – The lights must be manually turned on at the switching device. The Sensor will automatically turn the lights off once sufficient daylight is available in the space.NOTE: For dimming and switching systems, the lights can also be manually turned off at any time by using the dimming or switching device directly.B®Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299, U.S.A.Made and printed in the U.S.A. 12/09 P/N 041-261 Rev. AImportant Notes 1.   This Sensor is part of a system and cannot be used to control a load without a compatible dimming or switching device. Refer to the instruction sheets of the receiving devices for installation information.2. Clean Sensor with a soft damp cloth only. DO NOT use any chemical cleaners.3.   The Sensor is intended for indoor use only. Operate between 32 °F and 104 °F  (0 °C and 40 °C).4. DO NOT paint Sensor.5.   Use only high-quality lithium batteries, one (1) size CR2450, 3 V   (ANSI-5029LC,  IEC-CR2450). DO NOT use rechargeable batteries. Using improperly rated batteries could damage the Sensor.   CAUTION: DO NOT disassemble, crush, puncture, or incinerate the batteries. DO NOT dispose of batteries in normal household waste. Please recycle, take to a proper battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries. 6.   The range and performance of the RF system is highly dependent on a variety of complex factors such as: ·  Distance between system components ·  Geometry of the building structure ·  Construction of walls separating system components ·  Electrical equipment located near system componentsCAUTION: This product must not be used to control equipment which could create hazardous situations, such as entrapment, if operated accidentally. Examples of equipment which must not be controlled with this product include  (but are not limited to) motorized gates, garage doors, industrial doors, etc.11.11.22Removing Temporary Mounting StripRemove the Sensor from the mounting bracket by pulling downward.33.1Temporary Solid Ceiling Mounting   Use this procedure if the Sensor will be mounted on a solid, continuous ceiling surface such as drywall, plaster, concrete, or wood.Two 3M™ Command™ adhesive strips are provided for temporarily mounting and testing the Sensor on smooth, solid ceiling surfaces.  These strips are designed for easy, damage-free removal and are not reusable.  These strips should not be used for permanently mounting the Sensor (see section H. Permanent Mounting Methods ).  Carefully follow the removal instructions below to ensure the ceiling is not damaged during removal. NOTE:  DO NOT use the adhesive strips on ceiling tiles, as they will likely cause damage to the tile upon removal.Remove the mounting bracket from the base of the Sensor.  Peel the red “Command Strips” liner off of one of the adhesive strips and apply the strip to the flat side of the mounting bracket as shown in the diagram.  Press firmly.NOTE: Leave the removal tab exposed past  the edge of the bracket so it can be accessed  for removal later.2.12.32.42.52.62.72.82.9•  Easy-to-follow  InstructionsP/N 041-261Limited Warranty(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.This warranTy is in lieu of all oTher express warranTies, and The implied warranTy of merchanTabiliTy is limiTed To one year from purchase. This warranTy does noT cover The cosT of insTallaTion, removal or reinsTallaTion, or damage resulTing from misuse, abuse, or damage from improper wiring or insTallaTion. This warranTy does noT cover incidenTal or consequenTial damages. luTron’s liabiliTy on any claim for damages arising ouT of or in con nec Tion wiTh The manufacTure, sale, insTallaTion, delivery, or use of The uniT shall never exceed The pur chase price of The uniT.This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Patents pending. Lutron, Maestro Wireless, and the Sunburst logo are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. ANSI is a registered trademark of the American National Standards Institute. IEC is a trademark of the International Electrotechnical Commission. 3M and Command are trademarks of 3M Company. © 2009 Lutron Electronics Co., Inc.Technical AssistanceFor questions concerning the installation or operation of this product, call the  Lutron Technical Support Center. Please provide exact model number when calling.U.S.A. and Canada (24 hrs / 7days)    1.800.523.9466  Fax +1.610.282.6311 Mexico 8am – 8pm ET+1.888.235.2910Other countries 8am – 8pm ET    +1.610.282.3800  www.lutron.comFCC InformationNOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:· Reorient or relocate the receiving antenna.· Increase the separation between the equipment and receiver.· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.· Consult the dealer or an experienced radio/TV technician for help.Caution: Changes or modifications not expressly approved by Lutron Electronics Co. could void the user’s authority to operate this equipment.This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2.   This device must accept any interference received, including interference that may cause undesired operation.NOTE: Pull very slowly. NOTE: Do not pull at an angle.EnglishRadio Powr Savr™Installation Instructions  Please Read Before InstallingWireless Battery-Powered Daylight SensorLRF2-DCRB-WH  3 V   20 mA  434 MHzCompatible ProductsFor a full list of compatible products visit www.lutron.com/daylightsensorProduct DescriptionLutron’s Daylight Sensor is a wireless, ceiling-mounted, battery-powered device that automatically controls lights through RF communication with a dimming or switching device. The Sensor detects light in the space, and then transmits the appropriate commands to the associated dimming or switching device. When sufficient daylight is available, the system will decrease or turn off the electrical light. When insufficient daylight is available, the system will increase the electrical light. Press to test system functionalitySensor diffuserPress to assign load control1.21.31.41.51.6Note: Do not twist wire legs together. Tools You May NeedGetting Started:D1.1112ECalibrationCalibration must be done when daylight is available but not extremely brightSet Light Level•  Maestro Wireless Dimmer – Adjust each dimmer to a level in order to achieve the desired light level• Maestro Wireless Electronic Switch – Toggle the lights to onActivate the Calibration procedure by pressing the “Cal”  button on the front of the Sensor for approximately  6 seconds until the lens flashes solid. The LEDs on  all associated Dimmers or Electronic Switches should  be flashing.Select all Dimmers or Electronic Switches that you  want to calibrate by pressing the tap button.Move out of the way of the sensor so as to not interfere with the light measurements.Calibration automatically begins when the LED’s on all associated Dimmers or Electronic Switches stop flashing (approximately 30 seconds after pressing the “Cal” button).  The calibration will automatically turn lights on and off (total time approximately 3 minutes)The calibration is complete once the lights in the room flash three times. The Sensor and selected Dimmers or Electronic Switches automatically enter test mode once calibration is complete.Location for average size areasArrow points towards the area viewed by the sensor (toward windows)Bottom of sensorH = Effective Window HeightArea viewed by sensorH3 ft1-2 HLocation for narrow areas (corridors, private offices)Arrow points towards the area viewed by the sensor (away from window)2.212345FTuning the SystemAdjust the system’s target light level. This can be used to change the entire system, or one zone in the systemActivate Tuning mode by pressing the “Test” button on the  front of the Sensor for approximately 6 seconds until the lens  turns on solid.Select the Dimmer or Electronic Switch that you  want to adjust by pressing the tap button.Change the target light level by pressing the “Link” or the “Cal” button on the front of the Sensor. Pressing the “Test” button returns the settings to the default value.123GInstructions Install a Sensor in as little as 15 minutes.Press to calibrate systemBattery compartmentPermanent Mounting MethodsPermanent Drop Ceiling MountingAfter the Sensor has been temporarily mounted, leave the Sensor in place on the tile and either take the tile down or remove an adjacent tile to gain access to the legs of the mounting wire on the back of the tile.Twist the wire legs together tightly so the mounting bracket  remains snug against the tile.Replace the tile.If desired, repeat the wireless communication tests for verification.Permanent Solid Ceiling Mounting Drill one 3/16 in (4.6 mm) pilot hole for the provided screw anchor.Press the anchor into the hole and tap flush with a hammer.Place the flat side of the mounting bracket against the ceiling and install provided screw using a hand screwdriver.Attach the Sensor to the mounting bracket. If desired, repeat the wireless communication tests for verification. (See section  F. Testing the Daylight Sensor.) Lock your selection and exit Tuning mode by pressing the “Test” button on the front of the Sensor for 3 seconds.1.21.31.42.22.52.12.42.3H1.112Press “Link” 1-2 times to:· Make lights dimmer·  Make lights stay on less·  Make lights turn off sooner·  Require less light at the sensor to shut off lightsPress “Test” 1 time to:· Revert back to defaultPress “Cal” 1-3 times to:· Make lights brighter·  Make lights stay on longer· Make lights turn off later·  Require brighter light at sensor to shut off lights46Dimmer or SwitchDimmer or SwitchDimmer or SwitchDimmer or Switch

Navigation menu