Lutron Electronics 0062 Dimmer or Switch User Manual 7

Lutron Electronics Company Inc Dimmer or Switch 7

User Manual 7

Designer-Style RF Maestro®  Dimmers: RRD-6D, RRD-10D, RRD-10NDSwitch: RRD-8ANS Typical Power Consumption*: 0.2 WRemote Dimmer: RD-RDRemote Switch: RD-RS Typical Power Consumption*: 0 W120 V   50 / 60 HzInstallation InstructionsPlease Read Before InstallingMultigang InstallationsIn multigang installations, several controls are grouped horizontally in one multigang wallbox.When combining controls in a wallbox, derating is required; however, no derating is required for Remote Dimmers / Switches.Derating Chart Control Load Type End of Gang Middle of Gang-6DIncand. 500 W 400 WMLV 400 W /  500 VA 300 W /  400 VA-10D, -10NDIncand. 800 W 650 WMLV 600 W /  800 VA 500 W /  650 VA-8ANSLighting 6.5 A 5 AMotor 1/4 HP 5.8 A 1/6 HP 4.4 A Note: -8ANS controls have fins that need to be removed for multigang installations.  -6D, -10D, -10ND, -RD and -RS controls do not have fins that need to be removed for multigang installations.Short Circuit Check: Check the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit.1.  Turn power OFF at fusebox or circuit breaker.2.  Prepare wires. When making wire con-nections, follow the recommended strip lengths and combinations for the sup-plied wire connector.  Note: Wire connector provided is suit-able for copper wire only.Multi-Location Installation2-6D, -10D with RD-RDWiring Diagram 3Single Location Installation with Neutral-10ND, -8ANS120 V   50 / 60 HzBrassSilverBlackBlue Tighten1GreenGroundHot/LiveNeutralLoadWiring Diagram 2Single Location Installation-6D, -10DWiring Diagram 1Multi-Location Installation with Neutral2, 3 -10ND with RD-RD, and -8ANS with RD-RSDimmer / Switch 3  Neutral wire Dimmers / Switches  must be connected on the Load side of a multi-location installation.2  Up to 9 Remote Dimmers / Switches may be connected to a Dimmer / Switch. Total blue terminal wire length may be up to 250 ft (76 m).1  When using controls in single location installations, tighten the blue terminal without any wires attached. DO NOT connect the blue terminal to any other wiring or to ground.Status LEDs (Dimmer Only)Indicate light level; glows softly as night light when load is offTapswitchTap on/offDimming RockerPress to BrightenPress to Dim FASSTMFrontAccessibleServiceSwitchDimmer Operation Switch OperationLamp Replacement   WARNING - Shock Hazard - For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or even death.   For your safety during routine lamp replacement, remove power from the fixture(s) by pulling the FASS switch out on both the Dimmer / Switch and all Remote Dimmers / Switches.Troubleshooting GuideLutron Elec tron ics Co., Inc. 7200 Suter RoadCoopersburg, PA 18036-1299Made and print ed in the U.S.A.  7 / 09   P/N 044-157 Rev. AMounting DiagramControl Mounting ScrewsWallboxControlIncluded:Wire Connector (1)Mounting Screws (2)Adapter Mounting ScrewsWallplate adapter and wallplate purchased separately.DimmerStatus LED (Switch Only)Indicates light status; glows softly as night light when load is offTapswitchTap on/offFASSFrontAccessibleServiceSwitchBrassBlackBlue Tighten1GreenGroundHot/LiveNeutralLighting LoadDimmerBrassBlackBlueGreenGroundLighting LoadDimmerBrassBlackBlueGreenGroundRemote Dimmer120 V   50 / 60 HzBrassBlackBlueGreenGroundHot/LiveNeutralRemote DimmerBrassSilverBlackBlueGreenGroundLoadBrassBlackBlueGreenGroundRemote Dimmer/Switch120 V   50 / 60 HzBrassBlackBlueGreenGroundHot/LiveNeutralRemote Dimmer/SwitchPush-In Terminals: Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in terminal. Push screwdriver in while pulling wire out. Push-in terminals are for use with  14 AWG (1.5 mm2) solid copper wire only. DO NOT use stranded or twisted wire.  ORScrew Terminals: Wrap wire around screw terminal. Tighten securely to 5 in-lbs (0.55 N•m). Screw terminals are for use with 12 AWG  (2.5 mm2) or 14 AWG  (1.5 mm2) solid copper wire only. DO NOT use stranded or twisted wire.Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control.   Wire Connector: •  Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm2) or 12 AWG (2.5 mm2) wire•  Strip insulation 7/16 in  (11 mm) for 18 AWG (0.75 mm2) wire•  Use to join one or two 14 AWG   (1.5 mm2) or 12 AWG  (2.5 mm2) wires with one 18 AWG  (0.75 mm2) ground wire.Twist wire  connector tight.Removing Fins on -8ANSEach control has inside fins removedControl at middle of Gang has all fins removedDo Not remove outside fins on Controls at the end of gangControl Location for GangingInstallationWARNING - To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death.Dimmer / SwitchWiring Diagram 4Switch120 V   50 / 60 Hz3.  Wire controls as follows: For single location installation: See Wiring Diagrams 1 and 2. For multi-location installation: See Wiring Diagrams 3 and 4.4.  Push all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws pro-vided. Do not pinch the wires.5.  Attach the Lutron Claro or Satin Colors wallplate adapter and wallplate.   a.  Install wallplate adapter onto front of control(s).  b.  Tighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten).  c.  Snap wallplate onto wallplate adapter, and verify that control is aligned prop-erly.  d.  If controls are misaligned, loosen mounting screws appropriately. 6.  Restore power. Verify correct local operation (see Dimmer  Operation and Switch Operation).Symptom Probable Cause and ActionLights don’t switch ON / OFF when Tapswitch on Dimmer / Switch/  Remote is pressedPower not present   •  Circuit breaker OFF or tripped. Perform Short Circuit Check.   •  FASS is in the OFF position. Move FASS to the ON position by fully pushing it in. Check both the Dimmer  / Switch and all of the Remote Dimmers / Switches.Wiring   •  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires.   •   Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.   •  Installed in a neutral-based location. Check that neutral-based products are connected on the load side of a multi-location installation (see Wiring Diagram 4).Lamps burned out or not installed   •   Replace or install lamps.Dioded lamps   •   If dioded lamps are being used, replace with non-dioded lamps.Lights turn ON when Tapswitch is pressed, then turn OFFWiring   •   Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.Tapswitch stuck   •  Tapswitch stuck at another location. Check to see that tapswitches are not sticking for all control locations in the circuit.Light turns ON and OFF continuouslyLoad is less than minimum load requirement   •  Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications.Lights don’t switch ON/OFF from a KeypadImproper programming   •  Program according to the system Setup Guide.Out of RF range   •  Reposition to be within 30 feet (9 m) of an RF Signal Repeater.Wiring   •  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires.   •   Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams.Wallplate is warm Solid-state control dissipation   •  Solid-state dimmers and switches internally dissipate about 2% of the total connected load. It is normal for dimmers and switches to feel warm to the touch during operation.Use these instructions to install the model numbers listed above. For system setup instructions and tools visit  www.lutron.com/radiora2Load Specifications:Control Load Type Min. Load Max. Load-6D1Incand. 50 W 600 WMLV250 W / VA 450 W /  600 VA-10D1Incand. 50 W 1000 WMLV250 W / VA 800 W /  1000 VA-10ND1Incand. 10 W 1000 WMLV210 W / VA 800 W /  1000 VA-8ANS3Lighting 10 W / VA 8 AMotor 0.08 A 1/4 HP  5.8 A-RD See Dimmer 8.3 A-RS See Switch 8.3 A1  Dimmer Load Type: -6D, -10D and -10ND are    designed for use with permanently installed incandescent, magnetic low-voltage, or tung-sten halogen only. Do not install dimmers to control receptacles or motor-operated appli-ances. 2  Low-Voltage Applications: Use -6D, -10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. 3  Switch Load Type: -8ANS is designed for use with permanently installed incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A).Important NotesWARNING - To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equip-ment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death.Codes: Install in accordance with all local and national electrical codes.Grounding: When no “grounding means” exist within the wallbox, then the NEC® 2008, Article 404.9 allows a dimmer with-out a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the dimmer and use an appropriate wallplate such as Lutron’s Claro® or Satin Colors® wallplates. Neutral Wire: -10ND and -8ANS require a neutral wire connection in the wallbox where the Dimmer/Switch  is to be installed. If a neutral wire connection is not available in the wallbox, contact a licensed electri-cian for installation. Environment: Ambient operating tempera-ture: 32 °F to 104 °F (0 °C to 40 °C),  0% to 90% humidity, non-condensing. Indoor use only.Spacing: If mounting one control above another, leave at least 4 ½ in (114 mm) ver-tical space between them.Wallplates: Lutron® Claro and Satin Colors wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates.Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions.Wallboxes: Lutron recommends using 3 ½ in (89 mm) deep wallboxes for eas-ier installation. Several controls may be installed in one multigang wallbox — see Derating Chart.Remote Dimmers / Switches: Use only Lutron Maestro Remote Dimmers (-RD) with -6D, -10D, and -10ND controls. Use only Lutron Maestro Remote Switches (-RS) with -8ANS controls. Up to 9 -RD or -RS controls may be used with Maestro Dimmers or Switches. Mechanical 3- or 4-way switches will not work RF Device Placement: RF Dimmers and Switches must be located within 30 feet (9 m) of an RF Signal Repeater. Remote Dimmers and Switches are not required to be within a specific range of a repeater.For systems with an RF signal repeater, RF Dimmers or Switches cannot be controlled by the system until they are programmed in a system according to the system Setup Guide.EnglishRemote DimmerRemote SwitchThese products may be covered under one or more of the following U.S. patents: 4,992,709; 5,248,919; 5,399,940; 5,637,930; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,169,377; 6,687,487; 6,803,728; 6,969,959; 7,071,634; 7,166,970; 7,190,125; 7,362,285; 7,365,282; 7,382,100; 7,408,525; 7,548,216 and corresponding foreign patents. U.S. and foreign patents pending. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, Maestro, RadioRA and the sunburst logo are registered trademarks and RadioRA 2 and FASS are trademarks of Lutron Electronics Co., Inc.   ©2009 Lutron Electronics Co., Inc.Wallplate Adapter WallplateReturning Devices to Factory SettingsNote: Returning a control to its Factory Settings will remove the control from the system and erase all programming.Step 1 :  Triple tap the tapswitch on the control. DO NOT release after the third tap.Step 2 :  Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until the status LEDs start to scroll up and down quickly.Step 3 :  Release the tapswitch and immediately triple tap the tapswitch again. The status LEDs will scroll up and down slowly.The control has now been returned to Factory Settings.Warranty: For warranty information, please see the enclosed Warranty, or visit  www.lutron.com/resiinfo.Technical Assistance: U.S.A. / Canada: 1.800.523.9466 Mexico: +1.888.235.2910 Other Countries: +1.610.282.3800  24 hours a day, 7 days a week.* Typical Power Consumption test conditions:   Dimmer: load is off, nightlight mode enabled. Switch: load is off, nightlight mode enabled. Remote Dimmer / Switch: load is off.

Navigation menu