Lutron Electronics 0034 Lighting Control Transciever User Manual

Lutron Electronics Company Inc Lighting Control Transciever

Contents

User Manual

RJob Name:Job Number:Model Numbers:PageSPECIFICATION SUBMITTALSZ-CI-PRG Programming Control InterfaceDescriptionThe Stanza system is an easy-to-install and easy-to-use lighting control system designed especially for hotel guest rooms and similar applications. The system consists of wallbox dimmers, wallbox switches, line-voltage wallbox keypads, low-voltage interfaces, and lamp socket dimmer/switches. All of these devices communicate via radio frequency (RF) within each individual guest room.The Stanza programming control interface allows setup, commissioning, and modification of Stanza systems, and can also be used to integrate with a PC or other digital equipment that supports TCP/IP over 10/100 BaseT Ethernet or RS232 connections.Features• Integrates a Stanza guest room lighting control system with a PC or other digital equipment that supports RS232 or Ethernet TCP/IP communication. • Provides a basic serial string command set that allows a PC to monitor and control lighting.• Enables use of a PC to set up and commission Stanza systems.• At least one SZ-CI-PRG is required per job for commissioning or system modification. Programmed and commissioned systems do not require a SZ-CI-PRG to be present for continued operation.• Wireless connection allows easy mounting near integration device.sz-ci-prg-1 06.06.08Wireless Control InterfacesSZ-CI-PRGStanzaTM1FCC Information Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the seperation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Changes or modifications not expressly approved by Lutron Electronics Co. could void the user’s authority to operate this equipment. Operation is subject to the following: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RJob Name:Job Number:Model Numbers:PageSPECIFICATION SUBMITTALStandards:• FCC approved. Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC rulesPower:• Low-voltage PELV (Class 2: USA).• Operating Voltage: 15 - 24 V , 500 mA maximum.• AC adapter included (requires 120 V  outlet).Integration:• Provides one 10/100 Base T (autosensing) Auto-MDIX jack for connecting to an Ethernet network using TCP/IP.• Provides one DB9 RS232 jack for connecting to a serial device.• Baud rates supported over RS232: 9600, 38400, 115200.Key Design Features:• LED status indicators provide device diagnostics• Power failure memory: if power is interrupted, when the power is restored, device will retain all settings that were in place prior to the interruptionSystem Communication and Capacity:• Programming control interface communicates with other Stanza system components through radio frequency (RF) at 434 MHz• Multiple RF channels and thousands of system addresses prevent interference between systems• When used only for commissioning and programming, programming control interface does not count toward the single-system maximum of 31 Stanza devicesSpecificationssz-ci-prg-2 06.06.08Wireless Control InterfacesSZ-CI-PRGStanzaTMEnvironment:• Ambient operating temperature: 32 - 104 °F  (0 - 40 °C)• Maximum 90% non-condensing relative humidity• Indoor use only• Cannot be mounted in a metal enclosure (interferes with RF reception).Warranty:• 1-year limited warranty• 2-year full parts and labor warranty, with 8-year pro-rated parts replacement on commissioned systemsColor/Finish Codes:• Black only2
RJob Name:Job Number:Model Numbers:PageSPECIFICATION SUBMITTAL2.50(63.5)3.75(95.3)4.26(108.2)5.26(133.6)1.06(26.9)Mounting holesMounting1.  Mount the control interface directly on a surface, as shown in the Mounting Diagram, using screws (not included). When mounting, provide sufficient space for the antenna and connecting cables. The unit can be mounted in any orientation.    The unit cannot be mounted in a full metal enclosure. The antenna is not removable or remotely mountable. Mount in an accessible location for convenient access to addressing switches, LEDs, and terminal blocks.2.  Connect wiring as shown in the Wiring Diagram (next page).5.264.263.752.501.06Control InterfaceSurfaceMounting DiagramDimensionsDimensions are in inches (mm)6.0(152.4)sz-ci-prg-3 06.06.08Wireless Control InterfacesSZ-CI-PRGStanzaTMTerminal blocks on this sideLEDs and addressing switches on this side3
RJob Name:Job Number:Model Numbers:PageSPECIFICATION SUBMITTALWiring Diagram1234567RJ45 jack: Ethernet link  (to PC or A/V equipment)Ethernet link/ activityEthernet speedOn = 100 Mbit/secOff = 10 Mbit/secCAT5 Cable:  maximum 328 ft.  (100 m)To PC or AV equipment. For Ethernet link, use CAT5 cable provided to connect to auxiliary equipment. The Ethernet link LED will light continuously when link is present and will flash when there is link activity. Additional Ethernet network equipment and cables provided by others.PELV (Class 2: USA) Power in500 mA  12 - 24 V  (powered by 120 V  transformer, included). RS232 Cable:  maximum 50 ft.  (15 m)COMTxDRxDTo PC or AV equipment: Use the 9-pin cable provided, or follow the chart below.RS232 Pin Connect Wiring        Typical PC or           Pin onRS232 Interface     A/V equipment       9-pin cable   Common           Com    5   Receive           TxD    3   Transmit           RxD    2LED 1: PowerLED 2: Ethernet linkLED 3: UnusedLED 4: RS232 link TXLED 5: RS232 link RXLED 6: UnusedLED 7: UnusedSystem Communication Notes• Stanza lighting controls, keypads, and interfaces must be located within 20 feet (6 m) of a Stanza device configured as a repeater. Multiple devices configured as repeaters may be necessary to provide adequate coverage.• A total of 3 devices maximum can be configured as repeaters.• Devices configured as repeaters must be within 20 feet (6 m) of another device configured as a repeater.• Stanza lighting controls cannot be controlled wirelessly and Stanza keypads will not function until they are addressed and programmed.System Limits• 31 devices maximum• 20 feet (6 m) from device to repeater devices• Dimmers, keypads, or contact closure devices  can be repeatersSystem Overview20 ft. (6 m) max.from repeater device DimmerKeypad20 ft. (6 m) max.from repeater device      20 ft. (6 m)maximumsz-ci-prg-4 06.06.08Wireless Control InterfacesSZ-CI-PRGStanzaTMDiagnostic LEDs4

Navigation menu