                 RF uplink & RS485 downlink Repeater Model No.: CT103 Version:V1.4 Release Data:2018.07.23 Metering System Division Chengdu Kaifa Technology Co,Ltd User Manual
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    1 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Document Map The following documents are supplied for the Repeater installation, operation and maintenance.  CT103 Repeater User Manual The CT103Repeater User Manual gives an introduction of Repeater, include functions operation guide and product specification.
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    2 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Safety Instructions   Read all safety information and operating instructions before using CT103Repeater to avoid personal injury. FCC Warning: This device complies with part 15 of the FCC Rules.   Operation is subject to the following two conditions:   (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.    Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.    Note:  This  equipment has been tested and found to comply  with  the  limits for a Class  B  digital  device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can  radiate  radio frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular  installation.  If  this  equipment  does  cause harmful  interference  to  radio or  television  reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help.   This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    3 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Transport and Storage Before you transport and storage the Repeater, read and observe the clause 4 titled “Transport and storage” in this document.  Installation Power must be cut off before install or remove CT103Repeater. Before you install or remove the Repeater, find and read the “Product Installation Guide” first.    Operation 1.  Do not break the seal without authorized operator. 2.  Never remove the Repeater cover while the Repeater is in operation. Doing so will expose circuits and components and can lead to injuries, fire or damage to the Repeater. 3.  Repeater working voltage must less than 120% nominal voltage (120%Un). Long time over voltage can lead to fire or damage to the Repeater. 4.  Before you install or change external battery, read and observe the section 2.2 titled “external battery” in this document first. Incorrect operation may cause electrical shock!! 6.    Do not operate the Repeater with wet hands.                  For service and technical support information, please contact: Shenzhen Kaifa Technology (Chengdu) Co., Ltd. Add: No.1218 Hezuo Rd., Hi-Tech Development Zone (West),Chengdu, P.R.C.     Postcode: 611730 Tel: 86-028-65706888 Email: qiongyaodai@kaifa.cn www.kaifaRepeatering.com
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    4 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Content 1 PRODUCT INTRODUCTION ....................................................................................................................... 5 1.1 FRONT VIEW AND REAR VIEW .....................................................................................................................5 1.2 FEATURES LIST ............................................................................................................................................6 1.3 FUNCTION CHARACTERISTICS .....................................................................................................................7 2 REPEATER INSTALLATION ....................................................................................................................... 8 2.1 INSTALLATION GUIDE ..................................................................................................................................8 2.2 EXTERNAL BATTERY ....................................................................................................................................8 3 EVENT RECORD ........................................................................................................................................... 8 3.1 REPEATER’S EVENT RECORD .......................................................................................................................8 4 TRANSPORT AND STORAGE ..................................................................................................................... 9 ANNEXURE I WEIGHT AND DIMENSION .................................................................................................... 10 ANNEXURE II REFERENCED DOCUMENTS ................................................................................................ 11 ANNEXURE III RF CHANNEL .......................................................................................................................... 12
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    5 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   1  Product introduction CT103 is a repeater with RF Uplink & RS485 downlink. It’s a bridge between the Concentrator and Meter to transfer the meter’s data. The Repeater comes with an RF module that connects the Repeater via the RS485 interface. The communication Repeater can provide a path for forwarding weak signals, so  that  the  Concentrator  can  reliably  communicate  with  the  Repeater.  The  communication  is  not encrypted. The Repeater only implements transmit through function.   As a part of Kaifa repeater solution, the CT103 provides RS485 port and SPD detection port and integrated Repeating functions as described in section 1.3.   1.1  Front view and Rear view                             11 1 2 3 4 7 8 9 10 6 5 Figure 1 Front view Figure 2 Rear view
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:    Rev.: 1.3 Page:    6 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.               1.2  Features List Nominal Voltage  230V Voltage range  AC(80%Un to 120%Un) Quiescent Power Consumption  ≤3 W Quiescent Consumption Current  <20uA Degree of Water Protection  IP51 Degree of Insulation Protection  II 级 Communicate mode  Transparent transmission Communicate with Concentrator Modulation:Lora Frequency  :915.25M~917.75M TX power:≤ dbm RX  sensitivity:≤-119dbm(@SF=8,BW=500KHz,Data rate=12500bps) 6 dB BW:≥500KHz Communicate with Repeater  RS485(9600bps) Data retention  20 years (minimum) in case of power failure. Annual failure rate<0.5% Battery  Replaceable 3.6V/1200mAh lithium battery Environmental Repeater  install  in  Meter  Box,  the  Meter  Box  is  mounted outdoors Can resist external electromagnetic attack. Operating temperature range: +10℃~ +85℃(in Meter Box) Storage and transport temperature range: -45℃~ +85℃   Relative Humidity: 75%~100% Certification  ERC Reference standard    Comply  with  relevant  standards  requirements  for  ISM wireless device in CE,CCC,FCC Special Technological requirements  ROHS 1. Seal cap 2. RF communication LED 3. Power LED 4. Seal 5. External battery 6. Repeater cover sealing screw 7. Meter Box open detect switch 8. RS485 port 9. SPD detection port 10. Terminal screw 11. Hook 12.5
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   7 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   1.3  Function characteristics Repeat The Repeater only implements transmit through function.   SPD operative mode. Meter Box open detection. Power off event (last gasp). Data transfer mode Via RF channel to connect the Concentrator, HD(half-duplex). Via RS485 channel to connect the Meter, HD(half-duplex). Repeater networking Transmit discover command(command=0x1d, mac_des=0xffe,response_probability=100,allowed_time_slots=100)Meters will send their system-titles to Reapter(command=0x1e),DCU will receive the system-titles,Record_number = count(system-titles) some meters will fail because the RS485 conflict,and some meters will send system-titles OKFor every system-titlesRecord_number > 0YesEndNoSearches the meter-parameter table according to system-titleFound Get the sap from the meter-parameter tableInsert one record in the meter-parameter table with a new sapNoYesRegister meter (command=0x1c,HDLC  device_address), no response because broadcast)For every system-titlesYesNothing to doNothing to doReapter:all Transmit
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   8 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Event Log Power off. SPD OK. SPD FAIL. Meter Box open. Meter Box close.  2  Repeater Installation 2.1  Installation guide CT103Repeater should be installed at a dry Meter Box. Installation environment temperature must not exceed Repeater operation temperature range (+10℃~ +85℃); Working voltage must in the range of 184Vac~276Vac, 60±5%Hz. Please see Meter Box installation guide for details. 2.2  External battery External changeable battery can provide backup energy for Repeater’s RTC. The recommended battery size is LS14250E. Only authorize utility member can remove the battery, it is not allowable to remove battery for consumer. Please see the detailed dimension as following: 1)  Power off the Repeater, open the meter box, pull off the plug, and replace the battery, close the Meter Box. 3  Event record 3.1  Repeater’s event record When the event occurred, Repeater only transfers to Concentrator through RF module, it contains: event_code1 Power off: If power off, when power up again, Repeater can detect the last power off event, and report the last gasp event with date and time to concentrator. event_code2 SPD  OK:  SPD  give  a  disconnect  signal  to  Repeater  (only  detection  in  power  up situation). After five seconds, the  RF  LED will  alternating flicker and  Repeater will  report the SPD OK event with date and time stamp to concentrator. event_code3 SPD  FAIL:  SPD  give  a  connect  signal  to  Repeater  (only  detection  in  power  up situation). After five seconds, the  RF  LED will  alternating flicker and  Repeater will  report the SPD FAIL event with date and time stamp to concentrator. event_code4 Meter Box open: When Meter Box is opened, the RF LED will alternating flicker. After five  seconds,  Repeater  will  report  the  Meter  Box  close  event  with  date  and  time  stamp  to concentrator. event_code5 Meter Box close: If the Meter Box has been opened, When the Meter Box is closed, the RF LED will alternating flicker. After five seconds, Repeater will report the Meter Box open event with date and time stamp to concentrator.
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   9 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   4  Transport and Storage The  Repeaters  should  be  placed  on  kickstands and  the  height  should  not  exceed 5  layers. The storage condition should be clean, with an environmental temperature of between -25°C and +70°C, relative humidity of less than 95% and with an absence of rusty matter in the air.
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   10 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Annexure I Weight and Dimension The Repeater weighs 330g and is shaped in a box with a dimension of 65mm*153.4mm*80mm.
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   11 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Annexure II Referenced documents  No. Standard No. Title 1 IEC  62056-21  Ed. 1.0:2002 Electricity metering – Data exchange for meter reading, tariff and load control –  Part 21: Direct local data exchange 2 IEC  62056-46  Ed. 1.1:2007 Electricity metering – Data exchange for meter reading, tariff and load control – Part 46: Data link layer using HDLC protocol 3 IEC  62056-53  Ed. 2.0:2006 Electricity metering – Data exchange for meter reading, tariff and load control – Part 53: COSEM Application layer 4 IEC  62056-61  Ed. 2.0:2006 Electricity metering – Data exchange for meter reading, tariff and load control – Part 61: Object identification system (OBIS) 5 IEC  62056-62  Ed. 2.0:2006 Electricity metering – Data exchange for meter reading, tariff and load control – Part 62: Interface classes 6 ETSI  EN301  511 V9.0.2(2003-03)  7 ETSI EN301 489-1 V1.9.2(2011-09) Electromagnetic  compatibility  and  Radio  spectrum  Matters(ERM); Electromagnetic  Compatibility  (EMC)  standard  for  radio  equipment  and services; Part 1: Common technical requirements 8 ETSI EN301 489-7 V1.3.1(2005-11) Electromagnetic  compatibility  and  Radio  spectrum  Matters  (ERM); Electromagnetic  Compatibility  (EMC)  standard  for  radio  equipment  and services;  Part  7:  Specific  conditions  for  mobile  and  portable  radio  and ancillary  equipment  of  digital  cellular  radio  telecommunications  systems (GSM and DCS) 9 IEC 62052  10 IEC 62053
Title: CT103 RF Uplink &RS485 downlink Repeater User Manual DOC No.:  Rev.: 1.3 Page:   12 of14  Copyright Kaifa – Reproduction and communication of this document is strictly prohibited unless specifically authorized in writing by Kaifa.   Annexure III RF Channel Channel Frequency(MHz) Channel Frequency(MHz) Channel Frequency(MHz) 1 915.25 18 916.10 35 916.95 2 915.30 19 916.15 36 917.00 3 915.35 20 916.20 37 917.05 4 915.40 21 916.25 38 917.10 5 915.45 22 916.30 39 917.15 6 915.50 23 916.35 40 917.20 7 915.55 24 916.40 41 917.25 8 915.60 25 916.45 42 917.30 9 915.65 26 916.50 43 917.35 10 915.70 27 916.55 44 917.40 11 915.75 28 916.60 45 917.45 12 915.80 29 916.65 46 917.50 13 915.85 30 916.70 47 917.55 14 915.90 31 916.75 48 917.60 15 915.95 32 916.80 49 917.65 16 916.00 33 916.85 50 917.70 17 916.05 34 916.90 51 917.75  ***End of Document ***