Lifeline Systems 90-2359 Smoke Alarm User Manual Instructions insert

Lifeline Systems, Inc. Smoke Alarm Instructions insert

Contents

Instructions insert

                                                                                         Instruction Insert Smoke Detector P/N 95-0146-00                                                                                         of  31SMOKE DETECTOR PROGRAMMING INSTRUCTIONSFOR USE WITH THE MAINSTREET MESSENGERIMPORTANTThe Smoke Detector when activated, transmits an unique ID Code which must be“learned” by the Mainstreet Messenger before the detector can be used.Teach The Mainstreet Messenger the Smoke Detector ID Code1. Install the two Lithium 2/3AA Batteries into the smoke detector. Thecompartment allows installation is only one orientation.2. Wait 10 seconds after batteries installed, press and hold the smoke detector Testbutton until the alarm sounds, this will take about 15 seconds, to verify that theunit is functioning.3. Press the Options button on the Mainstreet Messenger (opening tones).4. Enter the passkey on the Mainstreet Messenger. The default passkey is #1234(accepted with a single beep).5. Press *02, the three memory buttons on the right will flash.6. Press memory button 2 or 3 (memory 1, top button, is usually assigned to theportable Call Button).7. Press and hold the smoke detector Test button. The moment the alarm sounds,release the Test button, the unit’s ID code was transmitted.8. The Mainstreet Messenger’s top row of three buttons will flash to indicate that itreceived an ID Code.9. The type of alarm needs to be indicated as Fire by pressing the ReminderButton.10. Press the Options button to finish.       Installing More Than One Smoke Detector On The Same Mainstreet Messenger
                                                                                         Instruction Insert Smoke Detector P/N 95-0146-00                                                                                         of  321. All smoke detectors installed to operate through the same Mainstreet Messengermust all have the same ID code.2. Programming the ID Code can only be achieved using a special Elcombe SystemsProgrammer.        Location Of Smoke DetectorsIMPORTANT      DO NOT INSTALL the Smoke Detector near large metal objects such as refrigerators     and ovens as they may interfere with the transmitted RF signal.1. The Smoke Detector is for Indoor Use ONLY.2. Typically, the Mainstreet Messenger can receive the transmission from theSmoke Detector up to 50 feet away. Once a location has been chosen, test thatthe Mainstreet Messsenger reacts by pressing the Test button on the SmokeDetector.    OPERATION     Smoke Detector Programmed With 12-Bit ID Code     The Smoke Detector monitors the condition of its batteries and will report a low     battery condition to the Mainstreet Messenger only during a real smoke alarm or     when a smoke detector Test button is initiated. The Mainstreet Messenger     responds to a low battery report from the Smoke Detector in the same manner that     would be reported as with a low battery Call Button.     That is, after the Test Button and the Alert at the Mainstreet Messenger has been     cancelled, the Mainstreet Messenger will flash the Cancel Button and beep     periodically.     Follow the instructions in the Mainstreet Messenger User’s Guide to verify the     battery condition of the smoke detector.          Smoke Detector Programmed With 20-Bit ID Code          The Smoke Detector monitors the condition of its batteries and reports the low
                                                                                         Instruction Insert Smoke Detector P/N 95-0146-00                                                                                         of  33          battery condition in the same manner as detailed for the 12-Bit ID Code.          The added benefit of the 20-Bit ID Code is that the smoke detector can be set to          report its battery condition every 8 hours regardless of good or bad battery.          Similarly, the smoke detector can be set to report every 8 hours only when the          battery is low.          TESTING     The Smoke Detector should be tested weekly by pressing the Test button.     Verify that the alarm sounds and that the Mainstreet Messenger respondscorrectly.          FUNCTIONAL DESCRIPTION          Refer to the OEM Instruction Manual which is shipped in the carton with every          unit for detailed functional information.                                                                                                                       Telephone 613-591-5678                                                                                                                                  Fax 613-591-1566                                                                                                       Technical Support 1-800-267-9004

Navigation menu