Leviton VRSDC Dimmers User Manual 1

Leviton Manufacturing Co., Inc. Dimmers 1

User Manual 1

2 Scene Controller with SwitchesCat. No. VRCS2, 120/240VAC, 50/60HzIncandescent-1000W – Magnetic Low-Voltage-1000VAElectronic Low-Voltage-1000W – Fluorescent-1000VA – Supplemental-1/4 HP/SwitchINSTALLATION INSTRUCTIONS Tools needed to install your SwitchSlotted/Phillips Screwdriver  Electrical Tape  Pliers   Pencil      Cutters    RulerLine up tabs and press in sides one at a time to attachPush in side at tab to releaseChanging the color of your Switch:Your switch includes three color options. The switch ships with the White frame attached. To change color of frame, proceed as follows:INSTALLING YOUR SWITCHNOTE: Use check boxes           when Steps are completed././&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! Step 1To rnillo TerminalRojo Marcado (RD)BKRDYL/RD4321To rnillo terminal Negromarcado (BK)To rnillo terminal Amarillo/Rojomarcado (YL/RD)Etiqueta terminal:Sólo use esta terminal paraaplicaciones de 3-Vías o más. Para aplicaciones unipolares,no quite esta etiqueta.Single Pole Wiring Application: Step 4• Makesurethattheendsofthewiresfromthewallboxare straight (cut if necessary).• Removeinsulationfromeachwireinthewallboxasshown.• Single-PoleApplication,gotoStep4. Step 3 Preparing and connecting wires:5/8" (1.6 cm) Strip Gage  (measure bare wire here)Cut (if necessary)CargaFase (Negro)Línea120 VCA, 60HzNeutro (Blanco)NegroBlancoVerdea tierraInterruptorSólo use esta terminal para aplicaciones de 3-Vías o más.Para aplicaciones unipolares no quite esta etiqueta.BKRD YL/RDWHLeviton’s Vizia RF +™ Z-Wave® components are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. Using RF technology allows Leviton to provide the greatest signal integrity possible. Each module in Leviton’s Vizia RF +™ component line is a Z-Wave® enabled device. In a Z-Wave® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. The Scene Capable Combo Switch is compatible with any Z-Wave® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave® logo.CAUTION:Remember to exercise common sense when using the Timer features of your Remote – especially when scheduling unattended devices. There can be some unexpected consequences if not used with care. DO NOT USE the remote for the control of high power heating appliances such as portable heaters. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps.• SwitchON/OFF• SceneCapable• ON/OFFLED• Twowaycommunication• RFreliability• Easeofinstallation–Nonewwiring• CompatiblewithotherZ-Wave® enabled devices FEATURES INTRODUCTIONFor non-standard wiring applications, refer to Wire Nut and Connector Size Chart1 - #12 w/ 1 to 3 #14, #16 or #182 - #12 w/ 1 or 2 #16 or #181 - #14 w/ 1 to 4 #16 or #182 - #14 w/ 1 to 3 #16 or #18WIRE CONNECTOR / # OF COND. COMBINATION CHARTWIRING COMBO SWITCH:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenswitchlead.• LineHotwallboxwiretoBlackswitchlead.• LineNeutralwallboxwiretoWhitedimmerlead.• Load1wallboxwiretoRedswitchlead.• Load2wallboxwiretoBlueswitchlead.• Proceed to Step 5.WARNINGS AND CAUTIONS:• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.• ViziaRF+™electroniccomboswitchesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleViziaRF+™controllers.WARNINGS AND CAUTIONS:• Recommendedminimumwallboxdepthis2-1/2".• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.• Usethisdeviceonlywithcopperorcoppercladwire.DI-000-VRCS2-02A-X1-BETAIdentifying your wiring application (most common): Step 2Single Pole1.  Line (Hot)2.  Neutral3. Ground4.  Load 15.  Load 224153NOTE: If the wiring in your wall box does notresembleanyofthesecongurations,consultaqualiedelectrician.• Restorepoweratcircuitbreakerorfuse.• PresspaduntillocatorlightisOFF.LightsshouldturnON. If lights do not turn ON, refer to the TROUBLESHOOTING section.Testing your Switch prior to mounting in wall box: Step 5• Positionallwirestoprovideroominoutletwallboxfordevice.• Ensurethattheword“TOP”isfacingupondevicestrap.• Partiallyscrewinmountingscrewsinwallboxmountingholes. NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device.Switch Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE. Step 6Installation may now be completed by tightening mounting screws into wall box. attach wallplate.Restore Power:Restore power at circuit breaker or fuse. Installation is complete. Step 7
DI-000-VRCS2-02A-X1-BETALIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, N.Y. 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties  of  any kind, including  merchantability and  fitness  for  a  particular  purpose,  but if  any  implied  warranty  is  required  by the  applicable jurisdiction,  the  duration of  any such  implied  warranty,  including  merchantability  and  fitness  for a  particular  purpose, is  limited  to  five years. Leviton  is  not  liable  for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.Programmer/Controller Cat. No. VRCPGNOTE: Programmer/Controller must be in close proximity to switch when including in the network.For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.viziarfplus.comProtected under U.S. Patent Number 6,388,399 and patents pending and licensed under U.S. Patents Numbers 5,905,442, and 5,982,103ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwoconditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouraged to try to correct the interference by one or more of the following measures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhich the receiver is connected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.FCC CAUTION:AnychangesormodicationsnotexpresslyapprovedbyLevitonManufacturing Co., Inc., could void the user's authority to operate the equipment. FCC COMPLIANCE STATEMENTNOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFpositionto facilitate access in the dark.Push Pad (Default settings)Turn ON from OFF position:Tap–LightsturnON.Turn OFF from ON position:Tap–LightsturnOFF.If there is a power outage, when the power is restored, the lights will return to the last setting before the power interruption.Cleaning:  Clean with a damp cloth. DO NOT use chemical cleaners. OPERATION TROUBLESHOOTING• LightsFlickering -  Lamp has a bad connection. - Wiresnotsecuredrmlywithwireconnectorsofswitch.• LightdoesnotturnONandLocatorLEDdoesnotturnON  -  Circuit breaker or fuse has tripped.  -  Lamp is burned out.  -  Lamp Neutral connection is not wired.• Remotedoesnotoperatelights -  Ensure that total wire length does not exceed 300 ft (90 m). Step 9 Excluding Switch from Z-Wave® Network:NOTE: It is very important to accurately Exclude devices from the network when moving or removing a device from a Z-Wave® network. This ensures that all information has been removed from your Primary Programmer/Controller's information table and is not counted on to be part of the mesh network.A)  If using a Leviton Z-Wave®Programmer/Controller,Cat.No.VRCPG,press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Choose Advanced Settings. Press the center button to select Network.B)  While standing close to the switch (approximately 1 foot), press the center button to <Exclude> device from the network.C)  While the Programmer/Controller is in the Exclusion mode and the locatorLEDisONonthecomboswitch,pressthepushpadtoturnon the switch. The Programmer/Controller will verify Exclusion and the locatorLEDwillturnOFF.  If the switch is flashing Amber while in the Exclusion mode, the Programmer/Controller is still trying to communicate with the switch. Wait until the device stops flashing, then press the push pad.Factory Default:If your switch is not responding, or you are unable to control it after you have tried to Include/Exclude it multiple times, it may be necessary to reset the switch to its original factory settings. To accomplish this, proceed as follows:• PressandholdbothbuttonsuntilthelocatorLED’sturnamber.LED’swillcontinue to flash once every second. While standing close to the combo switch (approximately 1 foot), press the center button to <Exclude> device from network or primary remote.CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINSYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES. Step 8 Including Combo Switch into Z-Wave® Network:NOTES:• Ifusinganon-LevitonProgrammer/Controller,refertothe Programmer/Controller instruction sheet for Including a device.• IfusingVRCPGinstallchecklistgodirectlytostepB.A) If using a Leviton Z-Wave®Programmer/Controller,Cat.No.VRCPG,press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Choose Advanced Settings. Press the center button to select Network.B)  Press and hold both buttons until the locator LED’s turn amber. Release buttons and locator LED’s should blink amber. LED’s will continue to flash once every second.C)  While standing close to the combo switch (approximately 1 foot), press the center button to <Include> device in the network. Device will include as a controller. NOTE:Thisistherststepoftheinclusionprocess.Onceyourcombo switch has been included as a controller, next include each switch as a standard switch device following steps D-F below. NOTE:Onlyonedevicemaybeincludedatatime.DO NOT put multiple devices into the Inclusion mode at any time.D)  While the Programmer/Controller is in the Inclusion mode and the LocatorLEDisONontheswitch,pressthepushpadtoturnonthe switch. The Programmer/Controller will verify inclusion and the LocatorLEDwillturnOFF.  If the switch is flashing Amber while in the Inclusion mode, the Programmer/Controller is still trying to communicate with the switch. Wait until the device stops flashing, then press the push pad. NOTE: If the Locator LED on the switch turns solid Red while including, there has been a communication error. Refer to Troubleshooting section.E)  The Primary Programmer/Controller will assign a node ID number (Name) for each switch in the device. NOTE: This ID number (Name) will be stored in the controller to be used for future reference. NOTE: You may name or edit your device at this time.F) The switch is now installed in the network.NOTE: If the switch has been successfully Included in the network andtheusertriestoIncludeitagainwithoutrstexcludingitfromthenetwork,theswitchwillretaintherstnodeIDithadreceivedandignorethe second.1 ON2 ON3 ON4 ONOFFOFFOFFOFFProgrammer/Controller Cat. No. VRCPGMenu ButtonCenter Button© 2009 Leviton Mfg. Co., Inc.Push PadsLocator Lights Step 8 cont’d
ARTWORK PRINT SPECIFICATIONSFOLD SCHEME / BINDERY DIAGRAMPART NUMBER REV DESCRIPTIONLine Screen:Angle:Resolution:Offset FlexoOtherBody Material:BinderyThickness:TrimPerfect BindDie cut Saddle StitchDrillFoldThe information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY,  INC. It is disclosed with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any pupose other than that for which disclosed.© 2009 Leviton Mfg. Co., Inc.Unpublished, All Rights ReservedPlantApprovals:ARN: Pilot Rev:ECO Number:Artwork Release Date:Artwork Print Specification Sheet Rev A04.epsPMCQAArtist:Notes:OtherCust OtherS & AMktg EngFOR LEVITON USE ONLYSPECIFICATIONS :PROCESS :MANUAL INTERIORS / BINDERY / FOLD SCHEME :COMMENTS :For manuals - designates cover specificationsDimensions:Material:Thickness:Finish::SpotCMYK1:4:3:2:Color(s):over1:4:3:2:Fonts:SpotCMYK1:4:3:2:Color(s):over1:4:3:2:Fonts:Fold LineDie Cut Punch/Drill HoleGlueKiss Cut CellophaneFold LinePerforateDie CutDie Line Key:2.3"4.25"14.0"8.5"Part No.(This panel) Part No.(This panel)DI-000-VRSC2-02A-X1-BETA8.5" x 14"40 lb. BlackHelvetica11Instruction sheet08 J. TangH. SanchezM. CrandallB. HamlitschP.  PatelA. MancusoV. LoNigro1448

Navigation menu