Leviton VRMX1 Light Dimmer User Manual manual

Leviton Manufacturing Co., Inc. Light Dimmer manual

manual

WARNINGS AND CAUTIONS:  To be installed and/or used in accordance with electrical codes and regulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.• UseONLYwiththeappropriateAdvanceTransformer120VMark10™Powerline or Lutron Tu-Wire®electronicballastsforcontrollingthespecicuorescentlampsinFluorescentMode.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,amotor-oratransformeroperatedappliance.• Usewithmagneticlowvoltagetransformers,incandescent,or120Vhalogenxturesonly.UseaLevitonelectroniclowvoltagedimmertocontrolelectronic(solidstate)lowvoltagetransformers.• WhenretrottingMark10™PowerlinedimmingballastsintoxturesthatoriginallyhadInstantStartballasts,thesocketsMUSTbereplacedwithRapidStartsocketstoallowproperdimmeroperationandpreventdamagetothedimmerballast.Refertotheinstructionsprovidedwiththeballast.• ViziaRF+TMdimmersarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+TM or ViziaRF+TMcontrollersformulti-locationdimming.WARNINGS AND CAUTIONS:• Whenmagneticlowvoltagecircuitsareoperatedatadimlevel,withalllampsinoperative,excesscurrentmayowthroughthetransformer.Toavoidpossibletransformerfailureduetoovercurrent,useatransformerthatincorporatesthermalprotectionorafuseattheprimarywindings.• Fluorescentlampsmustbeburnedinatfullintensityfor100hourspriortodimmingforproperdimmingperformance.Useonlyone(1)ViziaRF+™Incandescent/MagneticLowVoltageorFluorescentDimmerinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs)orupto4matchingremotes(withLEDs).Theremote(s)willturntheloadon(“atthelevelselected”fordimmersonly)atthecontrol.• Totalminimumloadmustexceed40W.• Dimmermayfeelwarmtothetouchduringnormaloperation.• Recommendedminimumwallboxdepthis2-1/2".• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.• Usethisdevice.SinglePole(Onelocation)or3-Way(Multi-location)Cat.No.VRMX1-1L,1000VA,1000W(Lighted)120VAC,60HzINSTALLATION INSTRUCTIONSFor3-Wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththedimmerwallboxandremotewallbox.1-#12w/1to3#14,#16or#182-#12w/1or2#16or#181-#14w/1to4#16or#182-#14w/1to3#16or#18DI-000-VRMX1-02A• Pulloffpre-cutinsulationfromdimmerleads.• Makesurethattheendsofthewiresfromthewallboxare.• Removeinsulationfromeachwireinthewallboxasshown.   Coordinating Remote DimmerBKRDYL/RD3214Terminal Screwmarked White (WH)TerminalScrew markedYellow/Red(YL/RD)5142BlackWhiteGreenRed35Yellow/RedHot (Black)Neutral (White)(PRIMARY SIDEOF MAGNETICLOW-VOLTAGETRANSFORMER)DimmerCoordinating Remote (no LEDs)YL/RD Yellow/    RedRDWhiteRed BlackBlack BKWHWhiteLine 120VAC, 60Hz(unused)(unused)GreenGroundGreenGroundSlotted/PhillipsScrewdriver ElectricalTape PliersPencil   Cutters  RulerInmulti-dimmerinstallations,thereductionofthedimmer’scapacityisrequired.Refertothechartformaximumloadperdimmer.IfinstallingDimmerinasingledeviceapplication,proceedwiththesection.IfinstallingDimmerina multi-deviceapplication,proceedasfollows:Yourdevicemayincludecoloroptions.Tochangecolorofthefaceproceedasfollows: UsecheckboxeswhenStepsarecompleted.ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFatcircuitbreakerorfuseandtestthatpowerisoffbeforewiring! Step 1 Step 2Ifthewiringinyourwallboxdoesnotresembleanyofthesecongurations,consultanelectrician.2431Line(Hot)  Neutral  Ground  Load   Line or Load   Neutral  GroundFirstTraveler–notecolorSecondTraveler–notecolor24153 5/8"  Pulloffpre-cutinsulationfromdimmerleads.Makesurethattheendsofthewiresfromthewallboxare.Removeinsulationfromeachwireinthewallboxas shown: (PRIMARY SIDEOF BALLAST)DimmerInsulatingLabelBlackHot (Black)BlackLine120 VAC,60HzNeutral (White)RedYellow/RedWhiteWhiteGreenGroundInsulating label:This wire is used in 3-way installations only.For single pole installations, do not remove this insulating label.Yellow/Red142BlackWhiteGreenRed3 Low-voltagedimmersareratedinVolt-Amps(VA).Themaximumbulbwattageisdeterminedbytheefciencyofthetransformerinthelow-voltagelightingsystem.Transformerefciencieswillvaryfromdifferentmanufacturers;consider80%efcientasaverage.Usethecharttodeterminemaximumbulbwattagefortypicaltransformerefciencyratings.Mark10™PowerlinedimmersareratedinVolt-Amps(VA).ThemaximumbulbwattageisdeterminedbytheefciencyoftheMark10™Powerline ballast.ThefollowingtableshowsthemaximumnumberofballaststhatcanbeconnectedtoasingledimmerfordifferentMark10™Powerline ballasts. Alsonotethatthetableshowsmaximumballastsformulti-ganginstallations.Todeterminetotalballastload,addthelinecurrentfoundontheballastlabelforallballastsinthecircuit.Thiswillindicatethetotalloadforthecontrol.sectionsDo not sectionsside section650W650VA800W800VASingle1000W1000VALoadIncandMagLV520WRating1000VASingle800WTwo Gang640W INTRODUCTIONLeviton’sViziaRF+TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’s ViziaRF+TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave®network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.TheSceneCapableIncandescent/MagneticLowVoltageorFluorescentDimmeriscompatiblewithanyZ-Wave® enabled network,regardlessofthemanufacturerandcanalsobeusedwithotherdevicesdisplayingtheZ-Wave® logo.RemembertoexercisegoodcommonsensewhenusingtheTimerfeaturesofyourremote,especiallywhenschedulingunattendeddevices.Therecanbesomeunexpectedconsequencesifnotusedwithcare.Forexample,anemptycoffeepotcanberemotelyturnedon.Ifthatshouldhappen,yourcoffeepotcouldbedamagedfromoverheating.Ifanelectricheateristurnedonbyremotecontrolwhileclothingisdrapedoverit,arecouldresult.theremoteforthecontrolofhighpowerheatingappliancessuchasportableheaters.Thisdevicewillnotcontrollightingthatisusedwithelectroniclow-voltageandhighfrequencypowersupplytransformers,norhighpressuredischargelamps(HIDlighting).Thisincludesmercury-vapor,sodiumvaporandmetalhalidelamps.• SoftfadeON/OFF• Scenecapable• ON/OFFLEDandBrightnesslevelLED• Twowaycommunication• RFreliability• Easeofinstallation–Nonewwiring• CompatiblewithotherZ-Wave®enableddevicesFORMAGNETICLOW-VOLTAGEAPPLICATIONS, CONNECTDIMMERONLYTOTHEPRIMARY(HIGH-VOLTAGE) SIDEOFAMAGNETICLOW-VOLTAGETRANSFORMER.WhenusingthecoordinatingremotewithoutLEDs,thedimmer canbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreendimmerlead.• LineHot(common)wallboxwireidentied(tagged)whenremoving oldswitchtoBlackdimmerlead.• FirstTravelerwallboxwiretoReddimmerlead.• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.• SecondTravelerwallboxwiretoYellow/Reddimmerlead .Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".• LineNeutralwallboxwiretoWhitedimmerlead."BK"and"RD"terminalsoncoordinatingremoteareunused. Tighten both screws.Maximumwirelengthfromdimmertolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoFirstTraveler.• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD".Thistravelerfromtheremotemustgotothe Yellow/Reddimmerlead.• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• CONNECTAMAGNETICLOW-VOLTAGEDIMMERONLYTOTHEPRIMARY(HIGH-VOLTAGE)SIDEOFAMAGNETIC LOW-VOLTAGETRANSFORMER.• GreenorbarecopperwireinwallboxtoGreendimmerlead.• LineHotwallboxwiretoBlackdimmerlead.• LoadwallboxwiretoReddimmerlead.• LineNeutralwallboxwiretoWhitedimmerlead.• Yellow/ReddimmerleadshouldhaveRedinsulationlabelafxed. IfinsulatinglabelisnotafxedtoYellow/Reddimmerlead, useelectricaltapetocover.• . TM PowerlineTM Powerline  Single GangTwo Ganged2 GangREZ-2Q18-M2-LDREZ-1T32REZ-2Q26REZ-1T32REZ-1T42REZ-1Q18-M2-BSREZ-1Q18-M2-LDREZ-2Q18-M2-BSREZ-1T32REZ-1T42-M2-BSREZ-1T42-M2-LDREZ-2Q26REZ-2Q26-M2-BSREZ-2Q26-M2-LDREZ-1Q18-M2-BSREZ-1Q18-M2-LDREZ-2Q18-M2-BSREZ-2Q18-M2-LDREZ-1T42-M2-BSREZ-1T42-M2-LDREZ-2Q26-M2-BSREZ-2Q26-M2-LDREZ-1T42-M2-BSREZ-1T42-M2-LDREZ-2T42-M3-BS CFTR32W/GX24Q 13 10 8CFTR32W/GX24Q 26 20 16CFTR32W/GX24Q 26 20 16CFTR26W/GX24Q 17 13 11CFTR26W/GX24Q 17 13 11CFTR26W/GX24Q 32 25 20CFTR26W/GX24Q 32 25 20CFTR18W/GX24Q 23 18 15CFTR18W/GX24Q 23 18 15CFTR18W/GX24Q 46 37 30CFTR18W/GX24Q 46 37 30CFQ26W/G24Q 17 13 11CFQ26W/G24Q 17 13 11CFQ26W/G24Q 17 13 11CFQ26W/G24Q 32 25 20CFQ26W/G24Q 32 25 20CFQ26W/G24Q 32 25 20CFQ18W/G24Q 23 18 15CFQ18W/G24Q 46 37 30CFQ18W/G24Q 46 37 30CFM42W/GX24Q 20 16 13CFM32W/GX24Q 26 20 16CFM26W/GX24Q 17 13 11CFM26W/GX24Q 32 25 20151823CFM18W/GX24Q
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoThiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtoveyears..Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.PresstherighthalfoftheDIM/BRIGHTBar–Lightsbrightentodesiredlevel.PressthelefthalfoftheDIM/BRIGHTBar–Lightsdimtodesiredlevel.Ifyoucontinuetohold,thelightswillDIMto minimumlevelandthenturnOFF.WhenlightsareOFFyoucanchangethelightlevelthatthelightswillturnONtousingtheDIM/BRIGHTBar.Ifthereisapoweroutage,whenthepowerisrestored,thelightswillreturn to the last setting beforethepowerinterruption.Cleanwithadampcloth.DO NOTusechemicalcleaners.  -Lamphasabadconnection. -Wiresnotsecuredrmlywithwireconnectorsofdimmerorterminalscrewsofremote.  -  IfusinginadimmableuorescentapplicationseeAdvancedProgrammingFeatureB-4.  -Circuitbreakerorfusehastripped.  -Lampisburnedout.   -NeutralnotwiredtoDimmer(Whitewire). -Conrmthatthedeviceisbeingsuppliedfroma120V,60HzACsourceONLY. -Conrmthatunitisprogrammedproperly.Repeat"TOINSTALL"sectiontoverifythatithasbeenincludedintheZ-Wave® network.  -Minimumloadisunder40W. -ConrmthattheLoadbeingcontrolleddoesnotexceedthe1000VAdimmerlimit.  -Ensurethattotalwirelengthdoesnotexceed300ft. -Ensurewiringiscorrect.ProtectedunderU.S.PatentNumber6,388,399andpatentspendingandlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103 ItisveryimportanttoaccuratelyExcludedevicesfromthenetworkwhenmovingorremovingadevicefromaZ-Wave® network.ThisensuresthatallinformationhasbeenremovedfromyourPrimaryProgrammer/Controller'sinformationtableandisnotcountedontobepartofthemeshnetwork. IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSetting.PressthecenterbuttontoselectNetwork. Whilestandingclosetothedimmer(approximately1foot),pressthecenterbuttonto<Exclude>devicefromthenetwork. WhiletheProgrammer/ControllerisintheExclusionmodeandthelocatorLEDisONontheDimmer,pressthepushpadtoturnontheDimmer.TheProgrammer/ControllerwillverifyExclusionandthelocatorLEDwillturnOFF. IftheDimmerisashingAmberwhileintheExclusionmode,theProgrammer/ControllerisstilltryingtocommunicatewiththeDimmer.Waituntilthedevicestopsashing,thenpressthepushpad.Thelocatorlightwillilluminatewhentheload isintheOFFpositiontofacilitateaccessinthedark.Ifusingthedimmerina3-wayapplication,thelightswillturnONatbrightnesssetondimmer’s DIM/BRIGHTbar.Thelightingcanbecontrolled fromeitherthedimmerortheremotelocation.Tap–LightsturnONtopresetlevel.PressandHold–LightsturnONtofullbright.Tap–LightsturnOFF.       EnergySave:Setsthemaximumbrightnesslevelforenergysavings. MinimumBrightnessLevel:Setstheminimumdimminglevel.  PresetONLevel:Setstheturnonbrightnesslevelregardlessoftheprevioussetlightlevel(formerlyDimLock).  ONFadeRate:Setstheamountoftimeinsecondsittakesthe lightstoturnONtomaximumbrightness.  OFFFadeRate:SetstheamountoftimeinsecondsittakesthelightstoturnOFFfrommaximumbrightness.  LEDOptions:SetsthetimeperiodinsecondstheLocatorLEDandBrightnessdisplaywillstayonbeforeextinguishing.  FluorescentMode:AllowsdimmertocontrolMark10Powerline dimmingballasts.PressandholdthePushPadandthenthehalfofthe DIM/BRIGHTBar(^)for5secondsuntiltheLocatorLEDandleftmostLED(LED1)begintoblink. UponreleasingthePushPadandthehalfoftheDIM/BRIGHTBar(^),theLocatorLEDwillcontinuetoblinkoncepersecondandtherightmostLEDwillilluminatetodisplaythedeviceisinProgramMode.Thedefaultenergysavemodeis100%i.e.fullbright.Tochangethelevel,usethe DIM/BRIGHTBartomovethecorrespondingLEDtothedesireddiscretepresetlevelaccordingto.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,. TheLocatorLEDwillblink2timespersecondtoindicatethedeviceisinProgramMode.ThedefaultMinimumBrightnessLevelisLED1.Tochangethefrom1-50%,usetheDIM/BRIGHTBar.Thelightoutputwillreecttheminimumbrightnesslevelselected.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,. TheLocatorLEDwillblink3timespersecondtoindicateProgramMode. To change the current  from1-100%,usetheDIM/BRIGHTBar.Ifthisfeatureisnotdesired,pressandholdthehalfoftheDIM/BRIGHTBar(v)until no LEDislit(defaultsetting).BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeA.PressandholdthePushPadandthenthehalfoftheDIM/BRIGHTBar(v)for5secondsuntiltheLocatorLEDandrightmostLED(LED7)begintoblink. UponreleasingthePushPadandthehalfoftheDIM/BRIGHTBar(v),theLocatorLEDwillcontinuetoblinkoncepersecondindicatingthedimmerisinProgramMode. To change the ,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccordingto.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,. TheLocatorLEDwillblink2timespersecondtoindicateProgramMode. To change the ,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccording to .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,. TheLocatorLEDwillblink3timespersecondtoindicateProgramMode. To change the settings,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetsettingaccording to the .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextProgrammingModeB-4.Chart BLEDLED 1LED 2 (Default)LED 3LED 4LED 5LED 6LED 7FADE ON0 seconds (instant)0.5 seconds1.5 seconds3.0 seconds6.0 seconds10 seconds25 seconds0 seconds (instant)0.5 seconds1.5 seconds3.0 seconds6.0 seconds10 seconds25 secondsFADE OFFChart AWhen indicatorlight is at LED #7654321Light output is at100%97%95%90%85%80%75%Energy consumptionsavings amounts to0%5%8%16%24%29%34%• Restorepoweratcircuitbreakerorfuse.• PresspaduntillocatorlightisOFF.LightsshouldturnON.IflightsdonotturnON,presstherighthalfoftheDIM/BRIGHTBaruntilthelights brighten.  Step 5• Positionallwirestoprovideroominoutletwallboxfordevice.• Ensurethattheword“TOP”isfacingupondevicestrap.• Partiallyscrewinmountingscrewsinwallboxmountingholes.Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.Programmer/Controller mustbeincloseproximitytodimmerwhenincludinginthenetwork.IfthedimmerhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutrstexcludingitfromthenetwork,thedimmerwillretaintherstnodeIDit hadreceivedandignorethesecond. Step 9Chart B-3LEDLED 1LED 2LED 3LED 4LED 5LED 6LED 7LOCATOR LED TIMEOUTActiveActiveActiveActiveTurns off 5 sec. after useTurns off 5 sec. after useTurns off 5 sec. after useLED BRIGHTNESS DISPLAY OPTIONSActiveTurns off 5 sec. after useActiveTurns off 5 sec. after useLED Bar activeLED Bar turns off 5 sec. after useLED Bar turns off 5 sec. after useLED BrightnessDisplay1 2 3 4 5 6 7LeftmostLED=LED1RightmostLED=LED7• Thedevicewillexitprogrammingmodeafter3minutesofinactivity.• Pressingthepushpadatanytimeduringprogrammingwilladvancethedevicetothenextprogrammingmode.Ifyourdimmerisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthedimmertoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthedimmer,engagetheair-gapswitchandwait5seconds.PressthepushpadbackintotheframeandholdpushpaduntilthelocatorLEDturnsAmberandthenturnsRed.Thedimmerisnowreset.Oncethedimmerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINSYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES. IfusingaLevitonZ-Wave®  Programmer/Controller,Cat.No.VRCPG, presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSetting.PressthecenterbuttontoselectNetwork.  While standing close to the dimmer(approximately1foot),pressthecenterbuttonto<Include>deviceinthenetwork. Onlyonedevicemaybe includedatatime.DO NOTputmultiple devicesintotheInclusionmodeatanytime. WhiletheProgrammer/ControllerisintheInclusionmodeandtheLocatorLEDisONonthedimmer,pressthepushpadtoturnonthedimmer.TheProgrammer/ControllerwillverifyinclusionandtheLocatorLEDwillturnOFF. IfthedimmerisashingAmberwhileintheInclusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsashing,thenpressthepushpad. IftheLocatorLEDonthedimmerturnssolidRedwhileincluding,therehasbeenacommunicationerror.RefertoTroubleshooting section. ThePrimaryProgrammer/ControllerwillassignanodeIDnumber(Name)forthisdevice. ThisIDnumber(Name)willbestoredinthecontrollertobeusedforfuturereference. Youmayeditthedevicenameatthistime. .1 ON2 ON3 ON4 ONOFFOFFOFFOFF  Restorepoweratcircuitbreakerorfuse.   Step 8 • Ifusinganon-LevitonProgrammer/Controller,refertotheProgrammer/ControllerinstructionsheetforIncludingadevice.• IfusingVRCPG'sinstallchecklistgodirectlytostepB.ThedimmerbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitchandFirstTravelertoRemoteterminalmarkedBK.• SecondTravelerwallboxwirefromdimmertoremoteterminalscrewmarked"YL/RD".ThistravelerfromtheremotemustgotoYellow/Reddimmerlead.• LineNeutralwallboxtoremoteterminalscrewmarked"WH".W• GreenorbarecopperwireinwallboxtoGreendimmerlead.• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoReddimmerlead.• FirstTravelerLineHottoBlackdimmerlead.• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.• SecondTravelerwallboxwire to Yellow/Reddimmerlead.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked"YL/RD".• LineneutralwallboxwiretoWhitedimmerlead.• Hot (Bla c k ) Neutral (White)Dimmer Mat c hing Remote (with LEDs ) YL/RD RedYellow/RedWH BKBlackBlackWhite Ballast Line  120 V A C ,  60H z GreenGroundGreen  G r oun d   White PrimarySideInstallationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.Onthedimmeronly,engagetheair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard.LED'swillturnOFF.Thiswillstoppowertothexturetoreplacethebulb.Afterservicingiscomplete,pressthepushpadbackintoplacefornormaloperation. BKRDYL/RDAdditionalNeutral WireMatching Remote123Dimmer451Yellow/Red2BlackWhiteGreenRed354 DI-000-VRMX1-02AThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperationofthedevice.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.AnychangesormodicationsnotexpresslyapprovedbyLevitonManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatetheequipment.©2011LevitonMfg.Co.,Inc. TheLocatorLEDwillblink4timespersecondtoindicateProgramMode.Defaultoperationmodeisincandescent/magneticlowvoltagemode.Tochangefromnormaltouorescentmode,usetheDIM/BRIGHTBar.Pressandholdthe halfoftheDIM/BRIGHTBar(^)untilLEDislit(defaultsettingisLEDOFF).BytappingthePushPadthissettingwillautomaticallybesavedanddevicewillexitProgrammingModeB.
ARTWORK PRINT SPECIFICATIONSFOLD SCHEME / BINDERY DIAGRAMPART NUMBER REV DESCRIPTIONLine Screen:Angle:Resolution:Offset FlexoOtherBody Material:BinderyThickness:TrimPerfect BindDie cut Saddle StitchDrillFoldThe information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any purpose other than that for which disclosed.© 2011 Leviton Mfg. Co., Inc.Unpublished, All Rights ReservedPlantApprovals:PN-ARN: Pilot Rev:ECO Number:Artwork Release Date:Artwork Print Specification Sheet Rev A07.epsPMCQAArtist:Notes:OtherCust OtherS & AMktg EngFOR LEVITON USE ONLYSPECIFICATIONS :PROCESS :MANUAL INTERIORS / BINDERY / FOLD SCHEME :COMMENTS :For manuals - designates cover specificationsDimensions:Material:Thickness:Finish::SpotCMYK1:4:3:2:Color(s): over1:4:3:2:Fonts:SpotCMYK1:4:3:2:Color(s): over1:4:3:2:Fonts:Fold LineDie Cut Punch/Drill HoleGlueKiss Cut CellophaneFold LinePerforateDie CutDie Line Key:DI-000-VRMX1-02ABlack1 1Instruction sheetHelveticaH. Sanchez 06/23/11RS0066-3254J. Tang08 A. SteeleP. PatelA. MancusoV. LoNigro11" x 17"20 lb.Offset11"17"Part No.FINAL2.75"2.83"Part No.

Navigation menu