Leviton RZD06 In Wall Dimmer User Manual DI 000 ACI06 00A

Leviton Manufacturing Co., Inc. In Wall Dimmer DI 000 ACI06 00A

Exhibit D Users Manual per 2 1033 b3

PRELIMINARYSingle Pole (One location) or 3-Way (Multi-location)Incandescent DimmerCat. No. RZIØ6-1L, 600W (Lighted)120VAC, 60HzINSTALLATION INSTRUCTIONSBl Single-Pole Wiring Application:DI-000-RZI06-00A-X0Tools needed to install your Dimmer:Slotted/Phillips Screwdriver Electrical TapePliers PencilCutters RulerChanging the color of your Dimmer:Your Dimmer may include three color options. The Dimmer shipswith the White frame attached. To change color of frame, proceedas follows:Installing Dimmer by itself or with other devices:If installing Dimmer in a single device application, proceed with theINSTALLING YOUR DIMMER section. If installing Dimmer in amulti-device application, proceed as follows:MULTI-DEVICE APPLICATION:In multi-dimmer installations, the reduction of the dimmer’s capacityis required. Refer to the chart for maximum load per dimmer.INSTALLING YOUR DIMMERNOTE: Use check boxes       when Steps are completed.WARNING: TO AVOID FIRE, SHOCK, OR DEATH;TURN OFF POWER at circuit breaker or fuse and testthat power is off before wiring!Identifying your wiring application (mostcommon):NOTE: If the wiring in the wall box does not resembleany of these configurations, consult a qualified electrician.Step 2Step 3ONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFF2431241533-Way1. Line or Load (See importantinstruction below)2. Neutral3. Ground4. First Traveler – note color5. Second Traveler – note colorNOTE: For matching remote w/LEDsinstallation, the First Traveler becomesLine Hot.Step 4aWIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:•Green or bare copper wire in wall box to Green terminal screw.•Line Hot wall box wire to terminal screw marked "BK".•Load wall box wire to terminal screw marked "RD".•Dimmer terminal screw marked "YL/RD" should have Redinsulation label affixed.NOTE: If insulating label is not affixed to terminal screw marked"YL/RD", use electrical tape to cover.•Proceed to Step 5.Hot (Black)Neutral (White)LoadDimmerBKBlackWhiteRDGreenGroundLine 120VAC, 60HzYL/RDUse Terminal for 3-Way orMore Applications Only.For Single-Pole Applications,Do Not Remove This Label.BKYL/RD RDTerminalScrew markedBlack (BK)TerminalScrew markedRed (RD)TerminalScrew markedYellow/Red(YL/RD)Terminal Label:Use Terminal for 3-Way or More Applications Only.For Single-Pole Applications, Do Not Remove ThisLabel.4321Back Wire (either hole maybe used)Back wire openings use #14-12AWG solid copper wire only.•Make sure that the ends of the wires from the wall box arestraight (cut if necessary).•Remove insulation from each wire in the wall box as shown.•For Single-Pole Application, go to Step 4a.•For 3-Way Coordinating Remote (no LEDs) Application, goto Step 4b.WARNINGS AND CAUTIONS:•To be installed and/or used in accordance with appropriate electrical codes and regulations.•If you are unsure about any part of these instructions, consult a qualified electrician.•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.•Use with incandescent or 120V halogen fixtures only.•Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ RF remotes for multi-location dimming.•Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn thelight on at the brightness level selected at the dimmer.WARNINGS AND CAUTIONS:•Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).•Total minimum load must exceed 40W.•Dimmer may feel warm to the touch during normal operation.•Recommended minimum wall box depth is 2-1/2".•Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.•Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.•Use this device only with copper or copper clad wire. With aluminum wire use only devices markedCO/ALR or CU/AL.Single-Pole1. Line (Hot)2. Neutral3. Ground4. LoadStep 4a cont’dStrip Gage(measure barewire here or usegage on back ofthe dimmer)IMPORTANT: For 3-Way applications, note that one of the screwterminals from the old switch being removed will usually be adifferent color (Black) or labeled Common. Tag that wire withelectrical tape and identify as the common (Line or Load) in boththe dimmer wall box and remote wall box.5/8"(1.6 cm)Step 1√Cut(if necessary)Side Wire ConnectionSide wire terminals accept#14 AWG solid copper wire only.3-Way Wiring with Coordinating Dimmingor Switching Remote (no LEDs)Step 4bBKYL/RD RDBKYL/RD RD43215TerminalScrew markedBlack (BK)TerminalScrew markedRed (RD)TerminalScrew markedYellow/Red(YL/RD)Coordinating Remote24351DimmerStep 4b cont’dWIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:NOTE: When using the coordinating remote without LEDs, the dimmercan be installed on either the Line or Load side of the 3-way circuit.NOTE: Maximum wire length from dimmer to all installed remotescannot exceed 300 ft.•Green or bare copper wire in wall box to Green terminal screw.•Line Hot (common) wall box wire identified (tagged) whenremoving old switch to terminal screw marked “BK”.•First Traveler wall box wire to terminal screw marked “RD” (notewire color). This traveler from the dimmer must go to theterminal screw on the remote marked “RD”.•Remove Red insulating label from terminal screw marked“YL/RD”.•Second Traveler wall box wire to terminal screw marked “YL/RD”(note wire color). This traveler from the dimmer must go to theterminal screw on the remote marked “YL/RD”.WIRING COORDINATING REMOTE:Connect wires per WIRING DIAGRAM as follows:NOTE: Maximum wire length from dimmer to last remote is 300ft.•Green or bare copper wire in wall box to Green terminal screw.•Load wall box wire identified (tagged) when removing old switchto terminal screw marked “BK”.•First Traveler wall box wire (note color as above) to terminalscrew marked “RD”. This traveler from the remote must go tothe terminal screw on the dimmer marked “RD”.•Second Traveler wall box wire (note color as above) to terminalscrew marked “YL/RD”. This traveler from the remote must goto the terminal screw on the dimmer marked “YL/RD”.•Remote terminal screw marked "WH" should have Whiteinsulationlabel affixed.NOTE: If insulating label is not affixed to terminal screw marked"WH", use electrical tape to cover.•Proceed to Step 5.Hot (Black)Neutral (White)LoadDimmerCoordinating Remote (no LEDs)YL/RD YL/RDRDWHRDBKBKBlackDo not use forincandescentapplications.WhiteLine 120VAC, 60HzGreenGroundGreenGroundPush in side at tabto release Line up tabs andpress in side toattachMore than  Cat. No.  Single Two Devices 2 Devices  RZIØ6  600W     500W 400WMAXIMUM LOAD PER DIMMER FOR MULTI-DEVICEPreparing and connecting wires:This dimmer can be wired using side wire terminalscrews or through backwire openings. Chooseappropriate wire stripping specifications accordingly.(Coordinating Dimming Remote Depicted)FCC COMPLIANCE STATEMENTThis equipment has been tested and found to comply with the limits for a Class BDigital Device, pursuant to Part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residentialinstallation. This equipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is noguarantee that interference will not occur in a particular installation. If thisequipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment OFF and ON, the user isencouraged to try to correct the interference by one or more of the followingmeasures:•Reorient or relocate the receiving Antenna.•Increase the separation between the equipment and the receiver.•Connect the equipment into an outlet on a circuit different from that  to whichthe receiver is connected.•Consult the dealer or an experienced radio/tv technician for help.Compatible with enabled products!TM
PRELIMINARYTesting your Dimmer prior to mounting inwall box:LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchasedate, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in anymanner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.Step 5•Restore power at circuit breaker orfuse.•Press pad until locator light is OFF.Lights should turn ON. If lights do notturn ON, press the upper half of DIM/BRIGHT bar until the lights brighten.If lights still do not turn ON, refer tothe TROUBLESHOOTING section.TROUBLESHOOTING•Lights Flickering- Lamp has a bad connection.- Wires not secured firmly under terminal screws of dimmer  and/or remote.- Local switch, ON•Light does not turn ON and Locator LED does notturn ON- Circuit breaker or fuse has tripped.- Lamp is burned out.- Lamp Neutral connection is not wired.- Confirm that the device is being supplied from a 120V, 60Hz   AC source ONLY.- Confirm that unit is programmed properly. Repeat “TO INSTALL”  section to verify that it has been included in the Z-Wave™  network.•Intermittent dimmer operation- Minimum load is under 40W.- Confirm that the Load being controlled does not exceed the   600W dimmer limit.•Remote does not operate lights- Ensure that total wire length does not exceed 300 ft.For additional information, contact Leviton’s Techlineat 1-800-824-3005 or visit Leviton's website atwww.leviton.comNOTE: Dress wires with a bend as shown in diagram in order torelieve stress when mounting device.•Position all wires to provide roomin outlet wall box for device.•Ensure that the word "TOP" isfacing up on device strap.•Partially screw in mounting screwsin wall box mounting holes.Step 6 Including Scene Capable Dimmer intoZ-Wave™ Network:NOTES:•If using a non-Leviton Programmer/Controller, refer to theProgrammer/Controller instruction sheet for Including a device.A) If using a Leviton Z-Wave™ Programmer/Controller, Cat. No.RZCPG, press the Menu button and scroll down to SystemSetup. Press the center button to select System Setup Menu.Press the center button to select Network.Menu ButtonB) While standing close to the module (approx. 2-5 ft), press thecenter button to <Include> device in the network.NOTE: Only one device may be included at a time. DO NOTput multiple devices into the Inclusion mode at any time.C) While the Programmer/Controller is inthe Inclusion mode and the LocatorLED is ON on the dimmer, push thepush pad to turn ON the dimmer. TheProgrammer/Controller will verifyinclusion and the locator LED will turnOFF on the dimmer.If the dimmer is flashing Amber whilein the Inclusion mode, theProgrammer/Controller is still trying tocommunicate with the dimmer. Waituntil the device stops flashing,thenpress push pad.NOTE: If the locator LED on thedimmer turns solid Red whileincluding, there has been a communication error. Refer toTroubleshooting section.D) The Primary Programmer/Controller wil assign a node IDnumber (Name) for this module.NOTE: This ID number (Name) will be stored in the controllerlibrary to be used for future reference.NOTE: You may name or edit the node of this device at thistime.E) The dimmer is now installed in the network.NOTE: If a dimmer has been successfully Included in the networkand the user tries to Include it again without first excluding it fromthe network, the module will retain the first node ID it had receivedand ignore the second.Excluding Dimmer from Network:NOTE: It is very important to accurately Excludedevices from the network when moving or removing adevice from a Z-Wave™ network. This ensures that allinformation has been removed from your PrimaryProgrammer/Controller’s information table and is notcounted on to be a part of the mesh network.A) If using a Leviton Z-Wave™ Programmer/Controller, Cat.No. RZCPG, press the Menu button and scroll down toNOTE: Remote must be in close proximity todimmer when including in the network.RZCPGProgrammer/ControllerStep 7System Setup. Press the center button to select SystemSetup Menu. Press the center button to select Network.B) While standing close to the module, press the centerbutton to <Exclude> device from the network.C) While the Programmer/Controller is in the Exclusion modeand the locator LED is ON on the dimmer, press the pushpad on the dimmer. The Programmer/Controller will verifyExclusion and the locator LED will turn OFF on the dimmer.If the dimmer is flashing Amber while in the Exlusion mode,the Programmer/Controller is still trying to communicatewith the dimmer. Wait until the device stops flashing, thenpress the push pad.Factory Default:If your dimmer is not responding, or you are unable to control it afteryou have tried to Include/Exclude it multiple times, it may benecessary to reset the dimmer to its original factory settings. Toaccomplish this, proceed as follows:•On the dimmer, engage he air-gap switch (refer to Operationsection) and wait 5 seconds. Press push pad back into frameand hold push pad until the locator LED flashes Amber and turnssolid Red. The dimmer is now reset. Once the dimmeris reset, it will be necessary to Re-Include it to a network before itcan be used.CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOESNOT EXCLUDE THAT DEVICE FROM A NETWORK. THEEXCLUSION PROCEDURE MUST STILL BE FOLLOWED TOREMOVE THE DEVICE FROM THE PRIMARY CONTROLLER’SINFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN ASYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TORESPOND TO SOME DEVICES.Dimmer Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.Restore Power: Restore power at circuit breaker orfuse. Installation is complete.Installation may now be completed bytightening mounting screws into wall box.Attach wallplate.Step 8OPERATIONNOTE: The locator light will illuminatewhen the load is in the OFF position tofacilitate access in the dark.NOTE: If using the dimmer in a 3-wayapplication, the lights will turn ON atbrightness set on dimmer's DIM/BRIGHTbar. The lighting can be controlled fromeither the dimmer or the remote location.Gently lift bottomof push pad outPush Pad (Default settings)Turn ON from OFF position:Tap – Lights turn ON to preset level.Press and Hold – Lights turn ON to full bright.Turn OFF from ON position:Tap – Lights turn OFF.Press and Hold until lights DIM to lowest level and LED in LEDBrightness Display starts to blink – Lights remain ON for 10seconds and then turn OFF.DIM/BRIGHT BarBRIGHTEN:Press upper half of DIM/BRIGHT Bar  – Lights brighten to desired level.DIM:Press lower half of DIM/BRIGHT Bar – Lights dim to desired level.If you continue to hold the lower half of the DIM/BRIGHT Bar, thelights will DIM to minimum level and then turn OFF.NOTE: When lights are OFF you can change the light level that thelights will turn ON to using the DIM/BRIGHT Bar.If there is a power outage, when the power is restored the lights willreturn to the last setting before the powerinterruption.LEDBrightnessDisplay DIM/BRIGHTBarPushPad LocatorLightStep 9Air-Gap Switch: On the dimmer only,engage the air-gap switch by gently pullingthe bottom of the push pad until it liftscompletely out of the frame and a click isheard and all LED’s are OFF (refer toFigure). This will cut power to the fixture toreplace the bulb. After servicing iscomplete, push the push pad back fornormal operation.Cleaning: Clean with a damp cloth. DONOT use chemical cleaners.ADVANCED PROGRAMMING FEATURESMode 1 – Set Minimum Brightness: Set the minimum brightnesslevel that the lights can dim to prior to turning full OFF.Mode 2 – Set Dim-Lock: Set the brightness level that the lightswill turn on to regardless of the previous light level at which theywere turned OFF.Mode 3 – Set Fade Rate: Set the amount of time (in seconds) thatthe lights will have to turn ON or OFF. Fade rates can be set toone of five different settings.To Program:NOTE: Have a flashlight handy if this dimmercontrols the only light source in the room.1. On the dimmer only, engage the air-gapswitch by gently pulling the bottom of thepush pad until it lifts completely out of theframe and a click is heard and all LED’s areOFF.2. Press push pad back into frame and holdpush pad for 7 seconds until the locator lightand the top LED (LED 1) starts blinking.3. Upon releasing the push pad, the locatorlight will continue to blink once per secondindicating the dimmer is in Mode 1, SetMinimum Brightness mode. To change thecurrent Minimum Brightness level from 1-50%, use the DIM/BRIGHTBar. This setting will automatically be saved.4. Tap the push pad to change to Mode 2, Set Dim-Lock Level mode.The locator light will blink twice per second. To change the currentSet Dim-Lock level from 1-100%, use the DIM/BRIGHT Bar. If thisfeature is not desired, press and hold the lower half of the DIM/BRIGHT Bar until no LED is lit. This setting will automatically besaved.5. Tap the push pad to change to Mode 3, Set Fade Rate mode. Thelocator light will blink 3 times per second. To change the currentFade Rate, use the DIM/BRIGHT Bar to move the LED to thedesired preset level. This setting will automatically be saved bytapping the push pad to exit programming mode.The LED Brightness Display is separated into 7 segments. Each LEDrepresents a preset level with LED 1 (Preset 1) located at the top andLED 7 (Preset 7) located at the bottom. Refer to chart for settings anddefaults.NOTE: The dimmer will exit program mode after 3 minutes of activity.*default** LED #1 is located at the top*** The press and hold feature for the 10 second delayed off isdisabled in this mode.Preset  LED** Fade On          Fade Off1* 1     Approx. 1.5s from full off Approx. 3s from full on2***  2     No Fade No Fade3 3    No Fade Approx. 3s from full on4 4    Approx. 0.5s from full off Approx. 3s from full on5 5    Approx. 0.5s from full off Approx. 1.5s from full on6 6    Approx. 1.5s from full off Approx. 5s from full on7 7    Approx. 1.5s from full off Approx. 10s from full onFade Rate PresetsMode     Description Range  Default1Set Min. Brightness 1-50% 25%2Set Dim-Lock Level 0-100%, 0=no lock 03Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1Advanced Features Summary1234567LEDBrightnessDisplayDI-000-RZI06-00A-X0U.S. & Foreign Patents PendingCopyright© 2006 Leviton Manufacturing Co., Inc.All Rights Including Trade Dress Rights Reserved1 ON2 ON3 ON4 ONOFFOFFOFFOFFProgrammer/ControllerCat. No. RZCPGCenter Button
DOCUMENTATIONDOCUMENTATIONLEVITON INSTRUCTION SHEET/MANUALLEVITON INSTRUCTION SHEET/MANUALSPECIFICATIONSSPECIFICATIONSKKC 1/23/06HelveticaDI-000-RZI06-00A-X0BlackN/AFinal fold size:Final fold size:40 Lb. offset2.75" X 3"Overall size:Overall size:16.5" X 9"Paper size:Paper size:Final Fold SizeFOLD SCHEME9.0¨3.0¨2.75¨16.5¨Fold LinePanel Line1234#'s =    Fold SequenceCat. No.Cat. No.Cat. No.56

Navigation menu