Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598Certification ExhibitFCC ID: R7PSSMM1TRPFCC Rule Part: 15.247ACS Project Number: 11-0372Manufacturer: Landis+Gyr Technology, Inc.Model: Elster Solid State Meter ModuleManual
Draft 12/8/2012LANDIS+GYR CONFIDENTIAL INFORMATIONElster Solid State Meter ModuleQuick Start GuidePublication: 98-1258 Rev AB
Draft 12/8/2012Limitation on Warranties and LiabilityInformation in this document is subject to change without notice. This manual or any part of it thereof may not be re-produced in any form unless permitted by contract or by written permission of Landis+Gyr.In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages.Other brands or product names used are the trademarks or registered trademarks of their respective holders.© 2012 Landis+Gyr, Inc. All Rights ReservedElster Solid State Meter Module Quick Start GuidePublication: 98-1258Revision HistoryModification Date Revision Description Author9/10/2012 AA Released Vicky Costello12/3/2012 AB In Process Vicky CostelloLandis+Gyr30000 Mill Creek Avenue, Suite 100Alpharetta, GA 30022Website: www.landisgyr.comE-mail: solutionsupport.na@landisgyr.comTechnical Support: 1-888-390-5733Copyright© 2012 Landis+GyrAll rights reserved.
Draft 12/8/2012Landis+Gyr Confidential Information 98-1258 Rev AB 3Elster Solid State Meter Module Quick Start GuideOverviewThe Landis+Gyr Solid State Meter Module (SSMM) is designed to provide active energy (Kilo-Watt hour) data from Elster ALPHA Plus meters for use in residential and industrial commercial services. Figure 1 - 1.  Elster Solid State Meter ModuleThe meter kit includes:•Elster ALPHA Plus meter (A1D+ or A1T+)•Communication Module (SSMM)•Antenna
Draft 12/8/2012Elster Solid State Meter Module Quick Start Guide Landis+Gyr4 98-1258 Rev AB Landis+Gyr Confidential InformationRequired SoftwareTo work with the endpoint, you need at least one of the following software tools and documentation:•UtiliNet Solution Center (USC)•Meter Master Lite software•Meter Master Lite Quick Start Guide, publication number 98-0071•Elster ALPHA Plus softwareLandis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication number 98-0069.LabelsThe endpoint contains the following labels:Figure 2.  Label IdentificationTable 1. Elster Label Identification         Label Description1 Elster Meter Name Plate AEP compliant bar code that defines meter manufacturer, form, base, test voltage and current, watt-hour constant, serial number, and customer specific information.Manufacturer or customer specified serial numberManufacturer model and style number2 Landis+Gyr FCC ID Federal Communications Commission (FCC) Identification (ID) number assigned to the Landis+Gyr Solid State Meter Module for use in the Elster Alpha+ meter. 3 Landis+Gyr LAN ID Identifies the Solid State Meter Module to the Landis+Gyr billing network (printed and barcoded).123
Draft 12/8/2012Landis+Gyr Elster Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1258 Rev AB 5LAN IDThe LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN address. You cannot change the LAN ID of a radio.Features and FunctionsEndpoint RegistrationThe endpoint is automatically registered with the host system. No special tools are needed during installation.Admin packets are sent once each hour at a random time during the hour and play a crucial role in the automatic discovery of a meter by the Landis+Gyr system. They tell what kind of meter the module interfaces with, and other characteristics, such as the scaling constant, number of dials, and the firmware version.Admin packets include:Communication and Retrieving DataA microprocessor on the communications module counts pulses, records usage over multiple intervals, and transmits the information to the head end system. Several different packet types are sent.The most frequently sent packet contains the current rotational count and historical interval data that is useful for load profiling and time-of-use metering. Another less frequently sent (Admin) packet contains the current cumulative rotation count, useful for basic automatic meter reading applications. An Admin packet is sent once hourly and contains the information listed in Table 2, “Admin Packet Information,” on page 5.Power Outage/RestorationWhen an outage occurs, the meter uses an early power failure signal to alert the communication module. The communication module saves critical endpoint data to non-volatile memory, creates and sends a power fail message to the host system that includes the LAN ID.When power is restored, the communication module sends a Power Up message to the host system. This message includes the following information:Table 2. Admin Packet InformationMeter ID Identifies the customerProtocol ID Identifies the type of meter.Scaling Constant Tells how to convert meter readings into real units such as kWhNumber of dials Also referred to as displayed digits.Maximum Sensor Change Rate Tells how much the meter reading can change in a certain period of time.Firmware Version Specifies the firmware revision number.Current Cumulative Reading from the meter
Draft 12/8/2012Elster Solid State Meter Module Quick Start Guide Landis+Gyr6 98-1258 Rev AB Landis+Gyr Confidential Information•LAN ID•Total count•Last ten interval countsCustomer ServiceContact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733 with any questions or problems for guidance through the troubleshooting process.ComplianceFCC Class BThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the antenna.•Increase the separation between the equipment and receiver.•Consult Landis+Gyr or an experienced radio technician for help.UWARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment.
Draft 12/8/2012Landis+Gyr Elster Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1258 Rev AB 7RF ExposureIn accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained.Host FCC Label RequirementIn the final installation, the following information must be visible:“Contains FCC ID: R7PSSMM1TRPThis device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.”
Draft 12/8/2012Elster Solid State Meter Module Quick Start Guide Landis+Gyr8 98-1258 Rev AB Landis+Gyr Confidential InformationProduct SpecificationsTable 3. Elster Solid State Meter Module SpecificationsCategory Specification Value or RangeCompatible MetersElster ALPHA Plus Supported Meter FormsNOTE: Contact Elster Electricity for additional forms.Form Class1S 2001S 3202S 2002S 3203S 204S 2035S 2035A 2012S 20012S 32013S 20013S 32013A 10036S 2036A 209S 2010S 2010A 2016S 20016S 32016A 100ElectricalVoltage13.5VDC + 1V, 50mA (limited duration from meter’s power supply)Input Current 50mARFOutput Power 22-26.5 dBm Transmit Frequency 917.58 MHz (Fixed))
Draft 12/8/2012Landis+Gyr Elster Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1258 Rev AB 9Standards ComplianceFCC Title 47 CFR Part 15 Subpart B & CRadiated and Conducted EmissionsIEC 61000 4-2,3,4,5 Electromagnetic CompatibilityANSI C12.1-2011 Electricity MeteringANSI C12.20-2002 Electricity Meters StandardANSI C37.90.1Substation Standards - Fast Transient and Oscillatory WaveformANSI/IPC-A-610-Class 2 Workmanship Standard for Electronic AssembliesEnvironmentalGeneral Environmental Outdoor, rain-protected, sunlight-exposedOperating Temperature Range -40 to +85 C (under meter glass)Humidity 10% to 95% relative humidity, non-condensingMechanicalSize (Meter & Module)Refer to Elster Technical Manual, TM42-2182E for more details.Weight (Meter & Module)Refer to Elster Technical Manual, TM42-2182E for more details.Table 3. Elster Solid State Meter Module SpecificationsCategory Specification Value or Range
Draft 12/8/2012Elster Solid State Meter Module Quick Start Guide Landis+Gyr10 98-1258 Rev AB Landis+Gyr Confidential InformationPhysical DimensionsThe ALPHA Plus meter fits all standard S-base services. Meters with an A-base are also available. Figure 1 - 1 illustrates the S-base meter type and dimensions. NOTE: The dimensions are for reference purposes only and should not be used for construction.Figure 1 - 1.  S-base Meter Type and Dimensions in Inches (millimeters) - Front and Side ViewFigure 1 - 2 and Figure 1 - 3 illustrate the A-base meter type and dimensions.
Draft 12/8/2012Landis+Gyr Elster Solid State Meter Module Quick Start GuideLandis+Gyr Confidential Information 98-1258 Rev AB 11Figure 1 - 2.  A-base Meter Type and Dimensions in Inches (millimeters) - Front and Side ViewFigure 1 - 3.  A-base Meter Type and Dimensions in Inches (millimeters) - Back View
Draft 12/8/2012Elster Solid State Meter Module Quick Start Guide Landis+Gyr12 98-1258 Rev AB Landis+Gyr Confidential Information

Navigation menu