Koden Electronics RB719A Marine Radar RA55 User Manual C9 5 1Menu 1

Koden Electronics Co., Ltd Marine Radar RA55 C9 5 1Menu 1

C9

38    RA51/52/53/54/55 INSTRUCTION MANUAL – 05 5.5 MENU Operation ___________________________________________   List of MENU List of Main Menu MARK (MAIN-MENU) NAV (MAIN-MENU) ECHO (MAIN-MENU) SETUP (MAIN-MENU) EBL1 ON  OFF GAIN AUTO  MANU VRM1 ON  OFF MODE HU  HS  NU CU TM STC AUTO  MANU HARBOR EBL2 ON  OFF GZ ON  OFF FTC AUTO  MANU WINDOW PPI  SEMI3D/PPI PPI/PPI  PPI/NAV ALLPPI  ALL PPI/PPI MOB VRM2 ON  OFF OFF-C ON  OFF TUNE AUTO  MANU SEL WIN   FL EBL2 ON  OFF ST OFF  ST1  ST2 PICTURE DAY  NIGHT FL VRM2 ON  OFF SLEEP OFF  5min  10min 15min SYSTEM CHECK HDG OFF OFF ACQ (*1) TRACK OFF  15SEC  30SEC 1MIN  3MIN  6MIN CONT ///CSR ON  OFF DATA ON  OFF (*1) ZOOM ON  OFF RINGS ON  OFF DEL (*1) SL SHORT  LONG VAR RNG ON  OFF TGT NUM (*1)     TARGET  ALL DEL (*1)     CUSTOM KEY ASSIGNMENT PRESET1 (SUB-MENU) PRESET2 (SUB-MENU) NMEA PRESET ADJUST (SUB-MENU) ATA PRESET (*1) +MK LINE ON  OFF              (*1): For ATA List of Custom Menu PRESET1 (SUB-MENU) PRESET2 (SUB-MENU) HM FLSH ON  OFF GZ LEVEL 1-7 STERN M ON  OFF GZ MODE IN  OUT NORTH M ON  OFF HOLD ON  OFF ST’BY NAVI  NOR DISPLAY RDR  MONI  NAV BUZ VOL OFF  LOW  HIGH EXT BUZ OFF  CONT  INT RM UNIT NM  KM  SM IN P/R 1080  1024  2048  4096  360 DEPTH M  FT  FM OUT P/R 1080  1024  2048  4096  360 TEMP °C  °F DEMO ON  OFF EBL BRG REL  TRUE  MAG IR OFF  IR1  IR2 WP BRG TRUE  MAG SPD SET NMEA  MANU  0.0 KT  LOG 200P HEAD INPUT NMEA  SIN/COS  12BIT  10BIT LANGUAGE 16 countries HEAD TRUE  MAG SCAN SPEED STD  HIGH +MK MODE DIST/BRG  LAT/LON COLOR MONO  MULTI P TABLE 0 – 2        ADJUST (SUB-MENU) TIMING ADJ   HEAD ADJ   TUNING CAL.   ANTENNA 1-9 GAIN 1-30 STC 1-16        + ST’BY .75 . 25 HU  STC >  FTC >  TUNE >  ST >  TRACK >  ZOOM >  S/L > MARK NAV ECHO SETUP ECHO GAIN    > MANU AUTO MAIN-MENUSUB-MENU
RA51/52/53/54/55 INSTRUCTION MANUAL – 05    39 5.5.1 Mark Menu xxx  = keys to press Press the "MENU" key and select "MARK" from the four displayed menus by using the left or right arrows on the cursor pad.  The contents of the selected MENU will reveal beneath its name when it's highlighted. MENU  Left/Right    (Select MARK) 5.5.1.1 Bearing measurement (EBL1) (1) Select EBL1 from the pull-down display items using the up-down cursor key, and press the "ENT" key. (2) When the ON/OFF box is displayed beside the EBL1 item, select ON with the up-down cursor keys and press the "ENT" key.          (3) When the "ENT" key is pressed, electronic bearing line (EBL1) appears and the angle from the direction of the boat's heading will appear in a highlighted display at the lower left of the screen.  The displayed EBL angle is either relative to your heading, true or magnetic north, depending on the setting of "EBL BRG" in the "SETUP>CUSTOM>PRESET1" menu. (4) Rotate the control knob until the line is at the center of the target and read the bearing.  Press "ENT" or another function key and the EBL will remain onscreen.  To remove it, either use the menu or press the EBL1 soft key. Note:   1   xxx.x indicates the relative bearing measured by EBL1.  Up/Down  ENT  Up/Down  ENT  Control knob     ENT  (Select EBL1)   (Select ON) (EBL1 operation)    MENU                  Other function key  5.5.1.2 Determining distance (VRM1) (1) Select VRM1 from the pull-down display items using the up-down cursor key and press "ENT" key. (2) When the ON/OFF box is displayed beside the VRM1 item, select ON with the up-down cursor keys and press the "ENT" key. (3) When the "ENT" key is pressed, the variable range marker1 (VRM1) appears and the distance from it to the boat will appear in highlighted characters at the lower left of the screen. (4) Using the control knob, change the size of the ring until you place the marker on the front edge of the target.  Read the distance.  Press "ENT" or another function key and the VRM will remain onscreen.  To remove it, either use the menu or press the VRM1 soft key.     Up/Down  ENT    Up/Down     ENT    Control knob    ENT   (Select VRM1) (Select ON) (VRM1 operation)  MENU              Other function key  Note:   1    xx.xx NM indicates VRM1. MARK EBL1 > VRM1 > EBL2 > .75 .25 HU NAV ECHO SETUP MARK  >>>   0.23NM A OFF ON . 75 .25 HU + 1  0.0 ° .75 .25 HU +  1 0.00NM
40    RA51/52/53/54/55 INSTRUCTION MANUAL – 05 5.5.1.3 Bearing measurement (EBL2) Use the same procedure for placing EBL1.  The angle measurement will appear in highlighted characters at the lower right of the screen. Note:   2    xxx.x indicates EBL2.  5.5.1.4 Determining distance (VRM2) Use the same procedure for placing VRM1. The distance measurement will appear in highlighted characters at the lower right of the screen. Note:  2    xx.xx NM indicates VRM2.  5.5.1.5 Measuring the distance between two points (VRM2, FL VRM2) (1) Select FL VRM2 on the MARK menu and press the "ENT" key. (2) Select ON from the ON/OFF box and press "ENT".  “SET START POINT” is displayed and a small cross mark appears. Up/Down  ENT    Up/Down     ENT  ----------FL VRM2 is turned ON and the small cross (Select FL VRM2) (Select ON) mark appears.  (3) Use the left-right and up-down cursor keys to place the cross mark on one of the two echoes whose distance will be measured, and press the "ENT" key.  Up/Down &Left/Right     ENT --------------------------------Criterion of the reference point is set. (Place the cross cursor on an echo) (4)   Select VRM2 from the menu as described previously or press the "VRM2" soft key.  Rotate the control knob until it is on the second echo, then read the distance between the two echoes or points in the highlighted text at the lower right of the screen                Note: FL VRM2 center do not follow to the "ZOOM" and "OFF-C" modes.  5.5.1.6 Measuring the angle between two points (EBL2, FL EBL2) (1) Select FL EBL2 on the MARK menu and press the "ENT" key. (2) Select ON from the ON/OFF box and press "ENT".  “SET START POINT” is displayed and a small cross mark appears.   Up/Down  ENT  Up/Down  ENT --------- FL EBL2 is turned ON and the small cross mark appears. (Select FL EBL2) (Select ON) (3) Use the left-right and up-down cursor keys to place the small cross mark on one of the two echoes whose angle will be measured, and press the "ENT" key.       Up/Down &Left/Right     ENT   ------ Criterion of the reference point is set. (Place the cross cursor on an echo)  (4) Select EBL2 from the menu as described previously or press the "EBL2" soft key.  Rotate the control knob until it is on the second echo, then read the angle in the highlighted text at the lower right of the screen.  The angle is relative to either the boat's heading, true or magnetic north, depending on the setting of "EBL BRG" in the "SETUP>CUSTOM>PRESET1" menu.    .75   .25   HU 2  0.72NM Place the VRM2 on other target  SET START POINT .75 .25 HU To measure the distance between two targetsSmall cross mark Cross markFL VRM2    Indication of VRM2 Center of VRM2
RA51/52/53/54/55 INSTRUCTION MANUAL – 05    41             5.5.1.7 Erasing heading marker temporarily (HDG OFF) (1) Use the up-down cursor key to select HDG OFF from among the pulled down and displayed items. (2) Press the “ENT” key.  The heading marker is not displayed as long as you hold down the "ENT" key.  Up/Down →ENT  The heading marker is off as long as you press and (Select HDG OFF) hold the “ENT” key down.   5.5.1.8 Using parallel cursor (///CSR) Normally the EBL is used to measure the exact bearing from the position of your boat to a target.  However, you can also use parallel cursors. (1) Select ///CSR from the MARK menu, press "ENT" and select ON. (2) Press the “ENT” key.  Parallel cursors will appear on the screen.  As you move the EBL, the parallel cursors will also rotate. (3) To cancel the ///CSR function, either select OFF in the menu or press the ///CSR soft key. Up/Down  ENT  Up/Down (Select ON) ENT  Parallel cursor appears. (Select ///CSR)        Up/Down (Select OFF) ENT     Parallel cursor disappears. Note: Interval of ///CSR is same as fixed range marker.    ///CSR moves with EBL1.  5.5.1.9 Establishment of the indication of the RANGE RINGS (RINGS) (1) Select RINGS from MARK menu and press the “ENT” key. (2) Use the up-down key to select ON or OFF and press the “ENT” key  Up/Down  ENT     Up/Down (Select ON)  ENT ------------- Range rings appear. (Select RINGS)    Up/Down (Select OFF)    ENT ------------- Range rings disappear.  Number of range rings and range interval Radome antenna (RA51) Range 0.125  0.25 0.5 0.75 1.5 3 6 12 24 36 Number of Rings 2 2 2 3 6 6 6 6 6 6 Interval 0.0625 0.125 0.25 0.25 0.25 0.5 1 2 4 6 Open antenna (RA52) Range 0.125  0.25 0.5 0.75 1.5 3 6 12 24 48 Number of Rings 2 2 2 3 6 6 6 6 6 6 Interval 0.0625 0.125 0.25 0.25 0.25 0.5 1 2 4 8 Open antenna (RA53) Range 0.125  0.25 0.5 0.75 1.5 3 6 12 24 48 64 Number of Rings 2 2 2 3 6 6 6 6 6 6 4 Interval 0.0625 0.125 0.25 0.25 0.25 0.5 1 2 4 8 16  .75  .25  HU  2  20.3° FL EBL2 Origin of EBL2 Indication of EBL SET START POINT .75 .25 HU  Measure the angle between two points Small cross mark Cross mark.75 .25 HU  Not displayed while ENT key is held down. .75 .25 HU  EBL1 Parallel cursor
42    RA51/52/53/54/55 INSTRUCTION MANUAL – 05 Open antenna (RA54) Range 0.125  0.25 0.5 0.75 1.5 3 6 12 24 48 72 Number of Rings 2 2 2 3 6 6 6 6 6 6 6 Interval 0.0625 0.125 0.25 0.25 0.25 0.5 1 2 4 8 12 Open antenna (RA55) Range 0.125  0.25 0.5 0.75 1.5 3 6 12 24 48 96 120 Number of Rings 2 2 2 3 6 6 6 6 6 6 6 6 Interval 0.0625 0.125 0.25 0.25 0.25 0.5 1 2 4 8 16 20            5.5.1.10 Variable range function (VAR RNG) Using the "RANGE UP" and "RANGE DOWN" buttons changes the displayed range in  small predetermined increments. The VAR RNG function allows you to make the change in 0.1 NM increments using the up and down arrows on the cursor pad.  (1) Select VAR RNG from the MARK menu press "ENT", then turn on the function. (2) VAR   will be displayed at the upper left of the screen beside MODE.  Setting procedure Up/Down  ENT  Up/Down (Select ON) ENT -------VAR RNG function is turned ON (Select VAR RNG)  Up/Down (Select OFF) ENT -------VAR RNG function is turned OFF  Method of use Up/Down ----------------------------------------------------------------Range changes continuously RANGE UP &RANGE DOWN -----------------------------------Range changes in step (3) To cancel the VAR RNG function, turn it off using the menu or press the "VAR RNG" soft key.  5.5.1.11 Output the position of the cursor location to another NMEA device (TARGET). (1) Turn on the TARGET function in the MARK menu (2) Using the cursor pad, move the cursor cross so it is directly over the position you would like to send to another navigation unit. (3) When you press "ENT" the latitude and longitude data of the position will be output to the NMEA port in TLL format.  Up/Down     ENT  ----------------------------------Output the L/L position of the cursor (Select TARGET) Note: When you activate this function, nothing happens onscreen.  5.5.1.12 Determine the distance and bearing to a marker (+MK LINE). (1) Select +MK LINE from the MARK menu and turn it on. (2) A variable range marker and an electronic bearing line will appear onscreen. A cross marker will be at their intersection. This is the mark position. (3) The variable range marker and the electronic bearing line will follow the cross marker with the Up/Down and Left/Right cursor pad control. Use them to place the cross marker over the position to which you want to determine range and bearing. (4) The data will be displayed in the lower left corner of the screen. (5) Turn off the function using the menu or press the "+MK LINE" soft key. .75 .25 HU .75 .25 HU Range rings ON Range rings OFF
RA51/52/53/54/55 INSTRUCTION MANUAL – 05    43 Setting procedure Up/Down  ENT  Up/Down (Select ON) ENT ---------------+MK LINE function is turned ON (Select +MK LINE)  Up/Down (Select OFF) ENT ---------------+MK LINE function is turned OFF        .75 .25 HU .75 .25 HU +MK POS   230.0°    0.47  +MK POS   230.0°    0.47 +MK LINE  OFF +MK LINE  ON The distance/bearing marker follows to cross cursor. EBLs and VRMs can be used separately.

Navigation menu