MEASUREMENT/TECHNICAL REPORTCompany:  Krohne America, Inc.Model: BM702FCC ID:  JH5BM702Description: This is a report to support a request for a type acceptance.Equipment Type:  Radiolocation deviceReport prepared for: Krohne America, Inc.7 Dearborn RoadPeabody, MA 01960Phone: 978-535-6060Fax: 978-535-1720Report prepared by: Chad A. BellCurtis-Straus LLC527 Great RoadLittleton, MA  01460 USAPhone: 978-486-8880FAX: 978-486-8828
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 2 of 14Table of ContentsLETTER OF AGENCY..................................................................................................................................................3INTRODUCTION ..........................................................................................................................................................4Product Description.................................................................................................................................................5Related Submittal(s) Grants.....................................................................................................................................5Test Methodology.....................................................................................................................................................6Test Equipment Used ...............................................................................................................................................9Operating Frequency.............................................................................................................................................11Electric Field Strength Radiation Measurements ..................................................................................................11Frequency Stability ................................................................................................................................................ 13
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 3 of 14Letter of Agency
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 4 of 14IntroductionThis report is an application for Certification of a Transmitter operating pursuant to Part 90 of theFCC Rules, Code of Federal Regulations 47. The model number covered by this report is BM702.This report is designed to demonstrate the compliance of this device with the requirementsoutlined in Part 90 of CFR 47 using the methods outlined in Part 2 of CFR 47. The currentrevision date, October 1,1998, of each Part has been used for technical requirements.The confidential information and descriptions included in this application are detailed descriptionsof the products, block diagrams, component specifications, and schematic diagrams.  We herebyrespectfully request under the provision of section 0.457d of the code that the documents listedbelow be held confidential.Technical Descriptions and Block DiagramsSchematicsBill of MaterialsKrohne America, Inc. is requesting that the Technical Descriptions, Block Diagrams, Schematicsand Bill of Materials be kept confidential in the FCC application because of the proprietary designdeveloped by Krohne America, Inc. that is unique to the industry.
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 5 of 14Product DescriptionThe BM 702 level gauge is designed solely for measuring the level, distance, volume andreflection of liquids, pastes, slurries, particulate materials and solids.   Five different antennas areavailable for use with the unit depending on the application.  There are four horn antennas andone Wave-Stick antenna.  The Wave-Stack antenna has several different part numbers whichcorrespond to the different lengths of waveguide that lead to the radiating potion of the Wave-Stick.  We tested the 6in Wave-Stick.Unit TestedModel Number:  BM702Serial Number:  0/311883.001Antennas:3in horn 21163401004in horn 21130101006in horn 21130001008in horn 2112540100Wave-Stick 3159860600Related Submittal(s) GrantsThere are no other approvals required for this device.
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 6 of 14Test MethodologyRadiated emission testing was performed according to the procedures in ANSI C63.4 (1992).Radiated testing was performed at an antenna to EUT distance of 3 meters below 1 GHz, and ata distance of 3 or 1 meter(s) above 1 GHz.  The actual test distance used is noted in the test datasheets.  The device’s performance was investigated to 40GHz. The EUT was powered by a DCpower supply for all tests. All other performance tests were made in accordance with theprocedures outlined in Part 90 of CFR 47.Each of the antennas was investigated at the fundamental frequency to determine which was themost efficient radiator – this was the 8in horn antenna.  Using the 8in horn antenna, harmonicsand spurious emissions were checked from 7 – 40GHz.Test FacilityCurtis-Straus LLCAll testing for the range 30–40000MHz was performed at Curtis-Straus (A2LA Certificate Number:1627-01). The open area test site used to collect the radiated data is located at 527 Great Road,Littleton, MA 01460. Site “M” was used..
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 7 of 14
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 8 of 14Equivalent Radiated PowerConducted measurements of the transmitter output were not possible, since the horn antenna ispermanently affixed.  Therefore field strength measurements with a horn antenna were doneinstead.  The following is the calculation of the limit in field strength based on the limit in power.ERP = Equivalent Radiated PowerPD = Power DensityV = VoltsFundamental Maximum Measured Output =117.7dBµV/m = 0.767V/m @ 1mPD = (V/m)^2/(resistance of free space [Ω])PD =  0.7672/377PD =  0.00156W/m2ERP = 4πPD*R2ERP = 4π(0.00156)*12ERP = 19.6mW = 0.0196W = PfundEmissions 250% or more outside the fundamental should be attenuated by at least:43dB + 10 log Pfund25.9dBTo calculate the limit of the harmonics:E = 5.5/(distance) x SQRT(Ptot)       -    Formula for E-field from isotropic antennaPtot = 19.6mW – 25.9dB = 12.92dBm – 25.9dB = -13dBm = -43dBWPtot = 0.00005WE1m = (5.5/1) * SQRT (0.00005)E1m = 0.039V/m = -28.1dBV/m = 91.8dBµV/mE1m = 91.8 dBµµV/mTherefore the limit in field strength at 250% outside of the authorized bandwidth is as follows:E1m = 91.8 dBµµV/m
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 9 of 14 Test Equipment UsedSPECTRUM ANALYZERSXAnalyzer Model No. Company Serial No. Calibration DueXWHITE9kHz-22GHz 8593E HP 3547U01252 24-APR-2001XGREEN9kHz-26.5GHz 8593E HP 3829A03618 04-OCT-2000XBLACK9kHz-12.8GHz 8596E HP 3710A00944 28-JUN-2001XORANGE9kHz-26.5GHz E4407B HP US39440975 05-MAY-2001LISNSXLISN Model No. Company Serial No. Calibration DueXYELLOW-BLACK9kHz-30MHz 8012-50-R-24-BNC Solar 984735 26-OCT-2000OPEN AREA TEST SITES (OATS)XSite FCC Code IC Code VCCI Code Calibration DueX“F”Florida 93448 IC 2762-F R-468/ C-480 28-JUN-2001X“M”Maine 93448 IC 2762-M R-904/ C-480 22-MAY-2001ANTENNASXAntenna Model No. Company Serial No. Calibration DueXGREEN-BLACKBilog: 30MHz-2GHz CBL6112B Chase 2412 23-JUN-2001XBLACKHorn: 1-18GHz 3115 EMCO 9703-5148 31-MAY-2001XWHITEStd Gain Horn: 18-26.5GHz 3160-09 EMCO 9610-1068 10-MAY-2001HARMONIC MIXERXMixer Model No. Company Serial No. Calibration DueXHARMONIC MIXER26.5-40 GHZ11970A HP 2332A00900 24-MAY-2001
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 10 of 14PREAMPLIFIERSXPreamplifier Model No. Company Serial No. Calibration DueXWHITE1-20GHz SMC-12A MITEQ 426643 09-OCT-2001XBLACK0.01-2000MHz ZFL-1000-LN MiniCircuits/C-S n/a 01-MAR-2001XYELLOW-BLACK1-20GHZSMC-12A MITEQ 535055 17-OCT-2000XYELLOW18-26.5GHzAFS4-18002650-60-8P-4 MITEQ 467559 28-AUG-2001METEOROLOGICAL METERSXMeter Model No. Company Serial No. Calibration DueXTEMPERATURE/HUMIDITY GAUGE TH300 Dickson 9044101 27-MAR-2001XATMOSPHERICPRESSURE GAUGE BA928 OregonScientific C3166-1 21-AUG-2001TRACEABLE CLOCKSXClock Model No. Company Serial No. Calibration DueX5003 5003 ControlCompany 99026940 16-NOV-2000Unless otherwise noted the calibration interval is one year.  All equipment is calibrated using standardstraceable to NIST or other nationally recognized calibration standard.
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 11 of 14Measurement ResultsOperating FrequencyThis device operates at spread source from   8.8-9.8 GHz.Electric Field Strength Radiation MeasurementsRadiated Emissions TableCurtis-Straus LLC Date: 03-Jul-00 Company: Krohne America Table: 1Engineer: David Heald EUT Desc: BM702 Work Order: A0897Frequency Range:30-1000 MHzMeasurement Distance:3 mNotes:EUT not mounted in the tankEUT Max Freq:9.5 GHzAntenna Preamp Antenna Cable Adjusted CISPR Class B FCC Class BPolarization Frequency Reading Factor Factor Factor Reading Limit Margin Result Limit Margin Result(H / V) (MHz) (dBµV) (dB) (dB/m) (dB) (dBµV/m) (dBµV/m) (dB) (Pass/Fail) (dBµV/m) (dB) (Pass/Fail)EUT sitting on the table --- --- --- --- --- --- --- --- --- ---V86.037.222.48.90.824.540.5-16.0Pass40.0-15.5PassV122.041.122.413.01.032.740.5-7.8Pass43.5-10.8PassV126.038.022.313.21.130.040.5-10.5Pass43.5-13.5PassV134.034.822.312.61.126.240.5-14.3Pass43.5-17.3PassV154.038.422.311.41.228.740.5-11.8Pass43.5-14.8PassV166.046.422.310.71.336.140.5-4.4Pass43.5-7.4PassV170.049.622.310.61.339.240.5-1.3Pass43.5-4.3PassV174.046.022.310.41.335.440.5-5.1Pass43.5-8.1PassV186.048.022.410.41.437.440.5-3.1Pass43.5-6.1PassV190.045.122.410.41.434.540.5-6.0Pass43.5-9.0PassV230.039.222.412.21.730.740.5-9.8Pass46.0-15.3PassV254.033.422.513.31.826.047.5-21.5Pass46.0-20.0PassV270.033.622.513.71.926.747.5-20.8Pass46.0-19.3PassH294.034.422.514.42.028.347.5-19.2Pass46.0-17.7PassH306.031.922.514.72.026.147.5-21.4Pass46.0-19.9PassTable Result: Pass by -1.3 dB Worst Freq: 170.0 MHzTest Site:"M"Pre-Amp:BlackCable:65 ft RG8A/UAnalyzer:GreenAntenna:Grn-BlkRadiated Emissions TableCurtis-Straus LLC Date: 11-Oct-00 Company: Krohne America Table 2Engineer: Stacey C. Costa EUT Desc: BM702 Work Order: A0897Frequency Range:8.75-10GHzMeasurement Distance:1 mNotes:Comparison at fundamental to determine highest gain antennaAntenna Preamp Antenna Cable Adjusted --- ---Polarization Frequency Reading Factor Factor Factor Reading Limit Margin Result Limit Margin Result(H / V) (MHz) (dBµV) (dB) (dB/m) (dB) (dBµV/m) (dBµV/m) (dB) (Pass/Fail) (dBµV/m) (dB) (Pass/Fail)3 Inch --- --- --- --- --- --- --- --- --- ---H9322.087.118.040.72.2112.0------------------4 Inch------------------------------H9300.089.318.040.72.2114.2------------------6 Inch------------------------------H9319.091.918.040.72.2116.8------------------8 Inch------------------------------H9313.092.818.040.72.2117.7------------------Wavestick------------------------------H9322.090.818.040.72.2115.7------------------Test Site:"F"Pre-Amp:WhiteCable:3m SucoflexAnalyzer:OrangeAntenna:Black Horn
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 12 of 14Radiated Emissions TableCurtis-Straus LLC Date: 11-Oct-00 Company: Krohne America Table 3Engineer: Stacey C. Costa EUT Desc: BM702 Work Order: A0897Frequency Range:1-18GHzMeasurement Distance:1 mNotes:8in horn antennaAntenna Preamp Antenna Cable Adjusted --- FCC Part 90Polarization Frequency Reading Factor Factor Factor Reading Limit Margin Result Limit Margin Result(H / V) (MHz) (dBµV) (dB) (dB/m) (dB) (dBµV/m) (dBµV/m) (dB) (Pass/Fail) (dBµV/m) (dB) (Pass/Fail)H9313.0 92.8 18.0 40.7 2.2 117.7 --- --- --- --- --- ---noise floor18000.040.420.445.23.168.3---------91.8-23.5PassTest Site:"F"Pre-Amp:WhiteCable:3m SucoflexAnalyzer:OrangeAntenna:Black HornRadiated Emissions TableCurtis-Straus LLC Date: 11-Oct-00 Company: Krohne America Table 4Engineer: Stacey C. Costa EUT Desc: BM702 Work Order: EA0897Frequency Range:18-40GHzMeasurement Distance:1 mNotes:8in horn antennaAntenna Preamp Correction Antenna IF Cable Adjusted --- FCC Part 90Polarization Frequency Reading Factor Loss Factor Factor Reading Limit Margin Result Limit Margin Result(H / V) (MHz) (dBµV) (dB) (dB) (dB/m) (dB) (dBµV/m) (dBµV/m) (dB) (Pass/Fail) (dBµV/m) (dB) (Pass/Fail)noise floor 27000.0 15.4 22.5 23.0 38.9 0.3 55.1 --- --- --- 91.80 -36.7 Passnoise floor36000.013.822.523.241.40.356.2---------91.80-35.7PassTest Site:"F"Pre-Amp:BlackCable:SucoflexAnalyzer:OrangeAntenna:26.5-40Ghz with mixerConducted Emissions ChartCurtis-Straus LLC Date:26-Jul-00Company:Krohne AmericaTable No:5Engineer:Chad A. BellEUT Desc:BM702Work Order:EA0897Notes: Measured on the AC side of the DC supplyRange: 0.45 - 30.0 MHz LISN(s): Yellow-Black  Spectrum Analyzer: WhiteQuasi-Peak FCC Class B Average FCC Class B OverallFrequencyL1L2ReadingLimitResultL1L2ReadingLimitResultMargin(MHz)(dBµV)(dBµV)(dBµV)(dBµV)(Pass/Fail)(dBµV)(dBµV)(dBµV)(dBµV)(Pass/Fail)(dB)0.45 25.0 25.0 25.0 48.0 Pass 25.0 48.0 Pass -23.00.5528.328.228.348.0Pass28.348.0Pass-19.70.6525.826.026.048.0Pass26.048.0Pass-22.01.5626.126.026.148.0Pass26.148.0Pass-21.93.6325.826.026.048.0Pass26.048.0Pass-22.020.3026.026.026.048.0Pass26.048.0Pass-22.0
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 13 of 14Frequency StabilityWork Order:A0897Date(s):11-Aug-00Engineer:Mike Buchholz and Matt DeeterEUT:BM702Company:Krohne America Inc.Modifications since start date:noneModifications this test:noneTest Equipment Used:Analyzer: BlackB-M-A Inc Environmental Chamber Model SGTH-315Atmospheric Conditions:Temp:24.0°CHumidity:30.60%Pressure:1006mbarTemperature( oC) fL*   (GHz) % Deviation fH*   (GHz) % Deviation-308.8610.1479.7150.103-208.8380.1139.7120.134-108.8410.0799.7190.06208.8440.0459.7220.031108.8440.0459.7250.000208.8480.0009.7250.000308.8670.2159.7380.134408.8740.2949.7450.206558.8740.2949.7540.298Stability with 85% and 115% Input Voltage at 20oC24V8.8700.0009.7510.00020.4V8.8700.0009.7510.00027.6V8.8700.0009.7480.031*The fundamental is a spread frequency, swept from fL to fHFREQUENCY STABILITY DATA SHEET
FCC Application for Krohne America, Inc. ••FCC ID: JH5BM702 •• Report No. EA0897-1______________________________________________________________________________ 11-Oct-00_____________________________________________________________Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 Page 14 of 14Emissions Plots:Fundamental