Jotron AS TRON60GPS 406 MHz EPIRB with GPS User Manual Tron 60GPS vJ

Jotron AS 406 MHz EPIRB with GPS Users Manual Tron 60GPS vJ

Users Manual Tron 60GPS vJ

USERS MANUALwww.jotron.comTron 60STron 60GPS
2www.jotron.com www.jotron.com85525_UM_60S/GPS_ JAMENDMENT RECORDSAmend-ment noBy Date Page(s) Vers. Reason for change1 TH 23.12.2010 Total 32 A New Manual2 TH 25.02.2011 Ch. 3.1.2 B Changed battery info3 TH 18.04.2011 Page 13-29 C Re-arranged pic-tures/drawings4 TH 19.09.2011 Page 15, 22-25D Info update5 BR 10.11.2011 Page 24 E Info update on test6 TH 20.01.2012 Page 16-18, 30F Update text and images7 ØE 08.02.2012 6,16, 18, 20, 22 and 24  G Update text8 TH   H Text and pictures9 FIT 22.05.2012 6, 12, 16, 18, 26, 29-30   I Updated text10 BR 26.06.2012 6, 16    J Battery info and EPIRB registration
3www.jotron.com www.jotron.com85525_UM_60S/GPS_ JEC Declaration of Conformity, available at www.jotron.comABBREVIATIONS AND DEFINITIONSBAUDTransmission rate unit of measurement for binary coded data (bit per second)BITShort form of Binary Digit. The smallest element of data in a binary-coded valueBPSBits Per SecondCOSPAS COsmicheskaya Sistyema Poiska Avariynich Sudov (Space System for the Search of Vessels in Distress) EPIRB Emergency Position Indicating Radio BeaconGLOBAL POSITIONING SYSTEM (GPS)The NAVSTAR Global Positioning System, which consists of orbiting satellites, a network of ground control stations, and user positioning and navigation equip-ment. The system has 24 satellites plus 3 active spare satellites in six orbital planes about 20,200 kilometers above the earth.IECInternational Electro-technical CommissionIMOInternational Maritime OrganizationIBRDInternational 406MHz Beacon Registration DatabaseITUInternational Telecommunication Union
4www.jotron.com www.jotron.com85525_UM_60S/GPS_ JLEDLight Emitting DiodeLUT Local User Terminal (Ground Station)MCAMarine and Coastguard Agency (UK)MCC Mission Control CentreNOAANational Oceanic and Atmospheric Administration (USA)RCC Rescue Coordination CentreSARSAT Search and Rescue Satellite-Aided Tracking SystemSBMShore Based Maintenance – as required by SOLAS regulation IV/15.9.2 of     SOLAS 1974 as amended with, in accordance with MSC/Circ. 1039 guidelines for Shore-Based Maintenance (SBM) of Satellite EPIRBs within 5 years if:Passenger ships (> 12 passengers) and cargo ships (> 300GT) engaged in Inter-national voyages, shall perform SBM as follows:• Latest by the date of the EPIRB label with this text, or the battery Label, whichever is first•  When this EPIRB becomes due for SBM in accordance with national require-mentsVHFVery High Frequency -A set of frequencies in the 30-300MHz region.
5www.jotron.com www.jotron.com85525_UM_60S/GPS_ JIMPORTANTThe information in this book has been carefully checked and is believed to be accurate. However, no responsibility is assumed for inaccuracies.This equipment contains CMOS integrated circuits. Observe handling precau-tions to avoid static discharges which may damage these devices. Jotron AS reserves the right to make changes without further notice to any products or modules described herein to improve reliability, function or design. Jotron AS does not assume any liability arising out of the application or use of the de-scribed product. WARNING / IMPORTANTJotron AS is a prime manufacturer of safety equipment designed for rescue of human lives and their property. For safety equipment to be effective in line with the design parameters it is important that they are handled, stowed and main-tained in compliance with the manufacturers instructions. Jotron AS can not be held responsible for any damage caused due to incorrect use of the equipment or breach of laid down procedures or for failure of any specific component or other parts of the equipment.The chapter covering battery replacement is added for information only. Jotron AS does not take any responsibility for improper disassembling/assembling of the beacon. We strongly recommend all service to be done by authorized Jotron AS agents. In addition to normal service, Jotron AS agents have the necessary equipment and education to test the operational functions of the beacon. Non-original maintenance and/or service parts may destroy the equipment function and performance.
6www.jotron.com www.jotron.com85525_UM_60S/GPS_ JBATTERY SAFETY DATA SHEETPRODUCT NAME: Energizer BatteryTYPE NO.: L91 Volts: 1.5TRADE NAMES: ULTIMATE (L91)APPROXIMATE WEIGHT: 14.5 gCHEMICAL SYSTEM: Lithium/Iron DisulfideDESIGNED FOR RECHARGE: NoHAZARDS IDENTIFICATIONUnder normal conditions of use, the battery is hermetically sealed.Ingestion: Swallowing a battery can be harmful.Inhalation: Contents of an open battery can cause respiratory irritation.Skin Contact: Contents of an open battery can cause skin irritation.Eye Contact: Contents of an open battery can cause severe irritation.FIRST AID MEASURESIngestion: Do not induce vomiting or give food or drink. Seek medical attention immediately. CALL NATIONAL BATTERY INGESTION HOTLINE for advice and follow-up (202-625-3333) collect day or night.Inhalation: Provide fresh air and seek medical attention.Skin Contact: Remove contaminated clothing and wash skin with soap and wa-ter.Eye Contact: Immediately flush eyes thoroughly with water for at least 15 min-utes, lifting upper and lower lids, until no evidence of the chemical remains. Seek medical attention.Note: Carbon black is listed as a possible carcinogen by International Agency for Research on Cancer (IARC).FIRE FIGHTING MEASURESIn case of fire where lithium batteries are present, flood area with water or smother with a Class D fire extinguishant appropriate for lithium metal, such as Lith-X. Water may not extinguish burning batteries but will cool the adjacent batteries and control the spread of fire. Burning batteries will burn themselves out. Virtually all fires involving lithium batteries can be controlled by flooding
7www.jotron.com www.jotron.com85525_UM_60S/GPS_ Jwith water. However, the contents of the battery will react with water and form hydrogen gas. In a confined space, hydrogen gas can form an explosive mixture. In this situation, smothering agents are recommended. A smothering agent will extinguish burning lithium batteries. Emergency Responders should wear self-contained breathing apparatus. Burn-ing lithium-iron disulfide batteries produce toxic and corrosive lithium hydroxide fumes and sulfur dioxide gas.HANDLING AND STORAGEStorage: Store in a cool, well ventilated area. Elevated temperatures can result in shortened battery life. In locations that handle large quantities of lithium bat-teries, such as warehouses, lithium batteries should be isolated from unneces-sary combustibles.Mechanical Containment: If potting or sealing the battery in an airtight or wa-tertight container is required, consult your Energizer Battery Manufacturing, Inc. representative for precautionary suggestions. Do not obstruct safety release vents on batteries. Encapsulation of batteries will not allow cell venting and can cause high pressure rupture.Handling: Accidental short circuit for a few seconds will not seriously affect the battery. Prolonged short circuit will cause the battery to lose energy, generate significant heat and can cause the safety release vent to open. Sources of short circuits include jumbled batteries in bulk containers, metal jewelry, metal cov-ered tables or metal belts used for assembly of batteries into devices. Damaging a lithium battery may result in an internal short circuit.• The contents of an open battery, including a vented battery, when exposed to water, may result in a fire and/or explosion. Crushed or damaged batteries may result in a fire.• If soldering or welding to the battery is required, consult your Energizer rep-resentative for proper precautions to prevent seal damage or short circuit.Charging: This battery is manufactured in a charged state. It is not designed for recharging. Recharging can cause battery leakage or, in some cases, high pres-sure rupture. Inadvertent charging can occur if a battery is installed backwards.Labeling: If the Energizer label or package warnings are not visible, it is impor-tant to provide a package and/or device label stating:
8www.jotron.com www.jotron.com85525_UM_60S/GPS_ J- WARNING: Battery can explode or leak and cause burns if installed backwards, disassem-bled, charged, or exposed to water, fire or high temperature. Where accidental ingestion of small batteries is possible, the label should include:- WARNING: (1) Keep away from small children. If swallowed, promptly see doctor. Battery can explode or leak and cause burns if installed backwards, disassembled, charged, or exposed to water, fire or high temperature. TEST AND MAINTENANCE RECORDDATE N/T/B SIGN INSPN= New EPIRB installed, T= Test, B= New batteryTEST OF RADIO EQUIPMENTMonthly:Float-free and manual EPIRBs to be checked using the means provided for testing on the equipment. Check data for periodical maintenance requirement for float-free EPIRB.False alerts transmitted by EPIRBFalse alerts are a serious problem for the rescue service. Nearly 90% of EPIRB initiated distress alerts turn out to be false alarms.If for any reason, your EPIRB should cause a false alarm, it is most important that you contact the nearest search and rescue authority and tell them it was a false alarm. They can then stand down any rescue service (coast radio station or appropriate CES or RCC). Use any means at your disposal to make contact.
9www.jotron.com www.jotron.com85525_UM_60S/GPS_ JSwitch off the distress alarm by de-activating your EPIRB, as soon as possible.If your beacon is activated in a non-distress situation or a distress situation which has been resolved and you no longer require assistance, contact the nearest search and rescue authorities via the most expeditious means available with the following information: • Beacon ID number (15 character UIN):• Position (At time of activation):• Date of Activation:• Time of Activation (Time zone):• Duration of Activation:• Beacon marke and model:• Vessel Name/lD:• Circumstances/cause (if known):USAThe United States search and rescue authority is the U.S. Coast Guard. The pri-mary points ofcontact are:Pacific Ocean AreaUSCG Pacific Area Command CentreTel: +1 (510)-437-3701Atlantic Ocean / Gulf of Mexico AreaUSCG Atlantic Area Command CentreTel: +1 (757)-398-6231From Any LocationUSCG Headquarters Command CentreTel: +1 (800)-323-7233
10www.jotron.com www.jotron.com85525_UM_60S/GPS_ JTABLE OF CONTENT1  GENERAL DESCRIPTION  121.1  TRON 60S/ GPS  121.2  SYSTEM DESCRIPTION  131.2.1  SIGNAL DETECTION  131.2.2  DISTRESS LOCATION DETERMINATION   141.2.3  EPIRB REGISTRATION  152  TECHNICAL SPECIFICATIONS  182.1 GENERAL  182.2  COSPAS-SARSAT TRANSMITTER  182.3  NAVIGATION DEVICE  182.4  HOMING TRANSMITTER  182.5  BRACKETS    192.5.1  FLOAT FREE BRACKET FB-60  192.5.2  MANUAL BRACKET MB-60  193  EPIRB DESCRIPTION  203.1 GENERAL  203.1.1  MAIN MODULE WITH ANTENNA  203.1.2  BATTERY PACK  204 INSTALLATION  214.1 BRACKETS  214.1.1  FLOAT FREE BRACKET FB-60  214.1.2  MANUAL BRACKET MB-60  224.1.3  MOUNTING THE FB-60/MB-60 BRACKETS  225  OPERATION INSTRUCTIONS  235.1  MANUAL OPERATION  235.1.1  OUT OF BRACKET  235.1.2  FLOAT FREE BRACKET FB-60   245.2  AUTOMATIC OPERATION - FLOAT FREE BRACKET FB-60  255.3 TEST  25
11www.jotron.com www.jotron.com85525_UM_60S/GPS_ J6  PERIODICAL CONTROL  276.1  EVERY MONTH:  276.2  EVERY 12TH MONTH:  276.3  EVERY 2ND YEAR:  276.4  EVERY 5TH YEAR:   276.5  SERVICE PROCEDURE 2012  287 MAINTENANCE  297.1  EPIRB MODULE / BATTERY PACK  297.1.1  CHANGE OF BATTERY  297.2  HYDROSTATIC RELEASE REPLACEMENT  307.2.1  REPLACING THE RELEASE MECHANISM IN  30FB-60 BRACKET8  SPARE PARTS  319  SERVICE AGENTS  31
12www.jotron.com www.jotron.com85525_UM_60S/GPS_ J1  GENERAL DESCRIPTIONThe Tron 60S/GPS is emergency equipment consisting of:•  Tron 60S/GPS Cospas-Sarsat emergency EPIRB•  One of the following brackets:•  FB-60 - Automatic float free bracket•  MB-60 - Manual bracketThe Tron 60S/GPS EPIRB is developed to meet the regulations and rules for use on vessels and life rafts in the maritime service. Tron 60S/GPS meets the fol-lowing specifications for 406 MHz EPIRBs for use in search and rescue opera-tions at sea.See “Declaration of Conformity” document at www.Jotron.com for information of required standards.1.1  TRON 60S/ GPSThe Tron 60S/GPS is buoyant and have water activated contacts which will start DISTRESS transmission if deployed into water. Tron 60S/GPS are currently available with two different brackets, one manual type and one float free ver-sion. Both type of brackets prevents DISTRESS transmission if water spray are applied to the EPIRBs. The Float free bracket, FB-60 is a covered bracket with an hydrostatic release unit (HRU) which will release the Tron 60S/GPS if the bracket is submerged to a depth of 2-4 meters if the ship are about to sink. The Manual bracket, MB-60 is a simple bracket for those ships which does not need a float free version, or for those in need of an additional manual EPIRB in the wheelhouse as required by some national administrations. The manual bracket will also be used as a shipment bracket when Jotron send replacement units to customers. The purpose of the Tron 60S/GPS is to give a primary alarm to the search and rescue authorities. The EPIRB gives an immediate alarm when activated, transmitting the ID of the ship in distress. Care must be taken not to activate the EPIRB unless in an emergency situation, in such cases the user will be held responsible. For periodic testing a test function is implemented. During the test cycle the EPIRB does a self-test on the transmitters and on the battery status.
13www.jotron.com www.jotron.com85525_UM_60S/GPS_ JNo emergency signal is transmitted during the self-test.The battery of the EPIRB will last for at least 48 hours from activation of the EPIRB.1.2  SYSTEM DESCRIPTIONThe Cospas-Sarsat system was introduced in 1982 as a worldwide search and rescue system with the help of satellites covering the earth’s surface. Since the  introduction of the system more than 28000 persons have been rescued by the Cospas-Sarsat system (2009). Currently the system consists of 5 functional satellites in a polar orbit constellation, these satellites cover the entire earth’s surface and receive the emergency signal from the 406 MHz transmitter within the Tron 60S/GPS, more polar orbiting satellites will be available in the future, giving a faster location and rescue time. In addition several geostationary satellites are equipped with a 406 MHz tran-sponder, these satellites are not able to locate the Tron 60S/GPS but will give an early warning to the rescue forces, minimising the time from an emergency occurs till the rescue forces are at the site. Each emergency EPIRB in the system is programmed with its own unique code, therefore it is vital that the ships data that is given to the dealer you obtained your Tron 60S/GPS, is correct. It is also important that your EPIRB is registered in the database for each country. This database is normally located in the same country that the ship is registered.      1.2.1  SIGNAL DETECTIONWhen the Tron 60S/GPS is activated (manually or automatically) it trans-mits on the frequencies 121.5 MHz and 406.037 MHz. An analogue signal is emitted on 121.5 MHz and a digital signal is transmitted on 406.037 MHz.   After the Tron 60S/GPS is activated, the next passing satellite will detect the transmitted signal and   relay it to an antenna at a ground station, called LUT.The International Cospas-Sarsat System has ceased satellite processing of 121.5/243 MHz beacons from 1 February 2009.
14www.jotron.com www.jotron.com85525_UM_60S/GPS_ J1.2.2  DISTRESS LOCATION DETERMINATION The location of the distress signal is determined by taking measurements of the doppler shift of the EPIRB frequency when the satellite first approach and then pass the EPIRB. The actual frequency is heard at the time of closest approach (TCA). Knowing the position of the satellite and using the re-ceived doppler signal information, it is possible to determine the location of the Tron 60S/GPS from the satellite at the TCA. At the LUT, actually two positions are calculated. One is the actual position (A) and the other is the mirror image (B) position. A second satellite pass confirms the correct location (A).  Doppler-only accuracy is within 5 km (3 mi) (3.1 statute miles or 2.6 nautical miles)— that is, the position is sufficiently accurate for SAR purposes even after only one pass. What’s more, the most likely of the two ’mirror’ positions can be deter-mined valid with 98.5% accuracy after only one satellite pass. This accuracy can be increased to 99.3% using so-called ”combined Leo-Geo processing,” and this technique also enables accurate positions to be generated with as little as two or three bursts from the beacon (i.e. less than 4 minutes of transmission) and thus greatly increases the chances of being found even if the beacon is ultimately consumed by fire or is otherwise destroyed1.2.2.1  GPS ADVANTAGEPolar orbiting satellites(LEOSAR)Geostationary satellites(GEOSAR)Tron 60S Delayed alert (<90 min)Position by Doppler (5km)Immediate alert (<5 min)NO positionTron 60GPS(MMSI StandardLocation Protocol Long)Delayed alert (<90 min)Position by GPS (120m)Immediate alert (<5 min)Position by GPS (120m)Longer delay,Low resolution positionFast alert and accurateposition
15www.jotron.com www.jotron.com85525_UM_60S/GPS_ JTron 60GPS has been designed to operate with the Cospas-Sarsat system and will enhance further the lifesaving capabilities of conventional beacons. Please see below comparison between Tron 60S and Tron 60GPS depending on detection by polar orbiting or geostationary satellites.GPS position is updated every 5 minutes, and can also be tested in SELF TEST (On previous models, position updates was only allowed every 20 minutes and NOT allowed to be tested in SELF TEST)1.2.3  EPIRB REGISTRATIONNormally the MCC will contact the vessel or the contact person registered in a shipping register and/or an EPIRB register (Ships owner, family member etc.) be-fore alerting the RCC. This is to determine if the alarm from the EPIRB for some reason is a false alarm, and an expensive rescue operation can be avoided. Be-cause of this it is important that the ships data is correct in the shipping register or in the EPIRB database.You should register your beacon with the national authority associated with the country code in the hexadecimal identification (15 Hex ID) of your beacon.  You can register your beacon online with the Cospas-Sarsat IBRD if your country does not provide a registration facility and your country has allowed direct reg-istration in the IBRD:  www.406registration.comIf your country operates a national beacon registry, consult the document C/S S.007 ”Cospas-Sarsat Handbook of Beacon Regulations”  available at www.cospas-sarsat.org to obtain the point of contact.Some EPIRB registration links:USA: http://www.beaconregistration.noaa.govUK: http://www.mcga.gov.uk (search for ”EPIRB registration”)
16www.jotron.com www.jotron.com85525_UM_60S/GPS_ JUSA REGISTRATION CARDFor registration of the beacon, use this link:http://www.beaconregistration.noaa.gov Follow instructions you see on your screen.Other registrations methods are mail or fax. Forms are ready with correct infor-mation and it may be downloaded from the above web site.The Emergency Contact information has to be accurate, especially regarding the telephone number, as this will be used to validate an alert. Only if the bea-con registration and approximate location details can be confirmed will USCG (United States Coast Guard) launch an immediate rescue, otherwise there will be a delay whilst further alerts from the same source are received and verified.Registration address:NOAA/SARSAT Beacon RegistrationE/SP3Federal Building 4, Room 33205200 Auth Road, Suitland, MD 20746–4304.
17www.jotron.com www.jotron.com85525_UM_60S/GPS_ J
18www.jotron.com www.jotron.com85525_UM_60S/GPS_ J2  TECHNICAL SPECIFICATIONS2.1  GENERALBattery:     Lithium/iron disulfide, 12V/2900 mAh, 5 years service lifeHousing material:    Glass reinforced PolycarbonateDimensions:• Weight:    680 gram• Height:     340 mm• Max diameter:   128mmCompass safe distance:  0,85 mTemperature operating:  -20°C to + 55°C (-4°F to +131°F)Temperature storage:  -40°C to + 65°C (-22°F to +149°F)Operating life:    Minimum 48 hours at -20°C2.2  COSPAS-SARSAT TRANSMITTERFrequency:    406.037 MHz ±2 ppmOutput power:    5W  ±2 dBProtocols:    Tron 60S/GPS: Maritime, Serialized, Radio Call sign,    Location protocolsModulation:    Phase modulation 1.1  ±0.1 radData encoding:    Bi Phase LStability:       Short term:   ≤ 2 x10e      Medium term:   ≤ 10e      Residual noise:   ≤ 3 x10e      Bit rate:    400 b/s   Antenna:   Omni directional2.3  NAVIGATION DEVICEType:       22 Channel GPS ReceiverAntenna:      Chip type 2.4  HOMING TRANSMITTERFrequency:    121.500 MHzOutput power:    Up to 100 mWModulation:    A9, AM sweep tone between 300Hz and 1600Hz        Sweep range: 700 Hz      Sweep rate: 2.5 HzStability:      10 ppm over temperature rangeAntenna:      Omni directional-9-9-9
19www.jotron.com www.jotron.com85525_UM_60S/GPS_ J2.5  BRACKETS  2.5.1  FLOAT FREE BRACKET FB-60Materials:     Luran S/ ABSDimensions (hwd):     (385 x 151 x 148) cmWeight:       850 gRelease mechanism:   Jotron HRU kit (part. no. 86218)2.5.2  MANUAL BRACKET MB-60Materials:     PA6 + 30% fibre glas (Polyamide)Dimensions (hwd):    (156x 134 x 98.5) cmWeight:       150 g
20www.jotron.com www.jotron.com85525_UM_60S/GPS_ J3  EPIRB DESCRIPTION 3.1  GENERALThe Tron 60S/GPS consists of upper and lower housing mounted together with an equator ring with gasket. Tron 60S/GPS consists of the following main parts:• Main module with antenna• Battery pack3.1.1  MAIN MODULE WITH ANTENNAThe EPIRB module consists of:• The main board including all electronic circuitry and the main switch• Antenna with LED flash 3.1.2  BATTERY PACKThe Battery pack supplies the EPIRB module with 12 V power to keep the EPIRB transmitters active for 48 hours when activated, and for test sequences. The battery pack is attached inside the lower housing. The seawater contacts are mounted in the lower housing. The battery cells are mounted in a plastic battery holder.
21www.jotron.com www.jotron.com85525_UM_60S/GPS_ J4  INSTALLATIONWARNING:DO NOT INSTALL THE EPIRB NEAR STRONGMAGNETIC FIELDS THAT COULD ACTIVATE THE BEACON4.1  BRACKETSTwo different brackets are currently available for the Tron 60S/GPS.4.1.1  FLOAT FREE BRACKET FB-60When the Tron 60S/GPS is mounted in the float-free bracket, FB-60, it will operate as an automatic float free unit. The satellite float-free EPIRB should be located/installed so that the following requirements are fulfilled:• The EPIRB should, with greatest possible probability, float-free and avoid being caught in railings, super-structure, etc., if the ship sinks.• The EPIRB should be lo-cated so that it may be eas-ily released manually and brought to the survival craft by one person. It should therefore not be located in a radar mast or any other places which can only be reached by vertical ladder.The location should be well pro-tected from environmental conditions such as direct sea-spray, chemicals, oil, exhaust and vibrations.
22www.jotron.com www.jotron.com85525_UM_60S/GPS_ J4.1.2  MANUAL BRACKET MB-60When the Tron 60S/GPS is mounted in the MB-60 bracket, it will operate as a manual unit. This bracket is typically used to store the EPIRB inside the wheel-house or other protected areas of the ship. When the Tron 60S/GPS is mounted in the MB-60 bracket, the EPIRB can be activated as described in 5.1.1, but the sea water contacts are deactivated in the bracket. The bracket should be mounted in an easily accessible place where it can be removed in a hurry in case of an emergency.4.1.3  MOUNTING THE FB-60/MB-60 BRACKETSThe bracket is mounted with 5mm bolts according to the drawing. Use the bolts supplied with the bracket. The bracket could be mounted in either a vertical or horizontal position, whichever is the best regarding maintenance and operation. A vertical position is recommended.M5 bolts x 3
23www.jotron.com www.jotron.com85525_UM_60S/GPS_ J5  OPERATION INSTRUCTIONSWARNING• USE ONLY DURING SITUATIONS OF GRAVE AND IMMINENT DANGER• REPLACE THE BATTERY AFTER THE SATELLITE EPIRB IS OPERATED FOR ANY PURPOSE OTHER THAN A TESTTron 60S/GPS is designed to be operated either manually or automatically.  The EPIRB is always armed when located in the bracket. The EPIRB will automati-cally start to transmit when removed or ejected from the bracket and deployed into water. The EPIRB has an internal safety switch which prevents inadvertent activation through moisture, sea spray etc when located in the bracket.    5.1  MANUAL OPERATION 5.1.1  OUT OF BRACKETRegarding the 3 pictures above, follow instructions from 4-5 on page 23.1 2 3
24www.jotron.com www.jotron.com85525_UM_60S/GPS_ J5.1.2  FLOAT FREE BRACKET FB-60 For operation of the beacon in the bracket please follow instructions 1 to 7.It is not recommended to operate the beacon inside a life raft or under a cover or canopy. Do NOT tie the lanyard to the ship in distress, as this will prevent the unit to functioning if the ship sinks.1.  Remove the cotter pin from the bracket (FB-60)2.  Remove the FB-60 cover3.  Take out the EPIRB from the bracket4.  Pull the locking pin holding the main switch.5.   Move main switch to the left, to ON position. The LED indicator, located at the top of the antenna, will start to flash, indicating that the EPIRB is            operating.6.  Tie the beacon lanyard to you or to the survival craft7.   If possible keep the EPIRB in an open area, away from any metal objects (ship construction etc.) that may limit the satellite coverage. This is espe-cially important for Tron 60GPS, since it needs good reception to obtain a GPS position.NOTE: To stop transmission, move the main switch to READY position.WARNINGThe EPIRB can drop out of the FB-60bracket when releasing top cover
25www.jotron.com www.jotron.com85525_UM_60S/GPS_ J2 1Hold 15 sec.Only 1 flash = OK35.2  AUTOMATIC OPERATION - FLOAT FREE BRACKET FB-601.    The Tron 60S/GPS will automatically release from the bracket, float to the            surface and start to transmit when the EPIRB, in its bracket is deployed into         water at a depth of app. 2-4 meters (6 - 13 feet).2.   Transmission will continue until the EPIRB is lifted out of the water, and dried         off. The transmission can also be stopped by placing the EPIRB in the        bracket.5.3  TESTTo perform the self-test, the EPIRB has to be removed from the bracket.FB-60 bracket: Release FB-60 top cover by removing the cotter pin.1.    Push and hold switch in TEST position for 15 seconds. Keep hands and other         objects away from the antenna. 2.   Test passed after one single flash only! 3.   Release the switch and put the EPIRB back into the bracketWARNINGThe EPIRB can drop out of the FB-60bracket when releasing top coverRelease the switchafter 15 sec.
26www.jotron.com www.jotron.com85525_UM_60S/GPS_ JGPS TEST:NOTE: Limit this test to max. once/month as this test will reduce lifetime of EPIRB battery! The Tron60 GPS has maximum 60 GPS TESTs that can be performed during battery lifetime.1.    Move Switch to TEST twice within 3 seconds and release2.   EPIRB will BEEP shortly every 3 seconds until GPS position acquired3.   OK = 2 BEEPS  (see below description if Not OK)4.   Normal SELFTEST is performed after successful GPS TEST and position                transmitted on 406.037 MHz. GPS position may be received on an           EPIRB Tester for verificationThere are two possible error conditions during this test:a)   5 BEEPS = Did not acquire GPS positionb)   10 -” -   = Number of GPS TEST above limit (>60)EPIRB ERROR MESSAGESIf the self test detects a fault in the EPIRB module, one or more of the following indications are shown:Number of flashes:Fault indication:1 NONE2  Low power on 406 MHz transmitter3  Low battery voltage4  Low power on 121.5 MHz transmitter5  PLL on 406 MHz transmitter out of lock6  PLL on 121.5 MHz transmitter out of lock7  EPIRB module not programmed or programming not complete
27www.jotron.com www.jotron.com85525_UM_60S/GPS_ J6  PERIODICAL CONTROL6.1  EVERY MONTH:• Test  (see ch.5.3) What the self-test actually does is to send out a short test signal on 121,5 and 406,037MHz, testing the output of the transmitter. While transmitting the test signal, the battery voltage, output power and phase lock is tested. During the test of the 406MHz transmitter a test mes-sage is transmitted, this test message is coded with a special synchronization code and will not be recognized as real alert by the Cospas-Sarsat satellites• Visual Inspection -The Tron 60S/GPS should be easily removed and replaced in the Bracket  - Check for defects on the EPIRB or brackets - Make sure that the Tron 60S/GPS and Bracket are not painted or otherwise covered with             chemicals, oil, etc - Is the lanyard firmly attached to the Tron60S/GPS ? (and not tied to the vessel)• Check the expiry dates on: - EPIRB Battery - Hydrostatic Release Unit (HRU)6.2  EVERY 12TH MONTH:• Annual Test and Inspection Perform extended annual test according to IMO’s MSC/Circ.1040 of 406 MHz satellite EPIRBs as required by SOLAS IV/15.9  (If required by SOLAS or national regulation)• GPS Test (see ch. 5.3, last part)6.3  EVERY 2ND YEAR:• Replace Hydrostatic Release Unit (HRU) including Plastic Bolt  (FB-60 only) (Check expiry date on label)6.4  EVERY 5TH YEAR: • Battery change• SBM (see 7.1)
28www.jotron.com www.jotron.com85525_UM_60S/GPS_ J6.5  SERVICE PROCEDURE 2012WARRANTY CLAIMWarranty claims are valid until 5 years from delivery from our warehouse. The warranty is valid as long as service and battery replacement are carried out by authorized Jotron distributors or agents. All products are warranted against workmanship and factory defect, in material. Any warranty claims must be sent to Jotron, in writing.Jotron reserve the right to decide whether a defective unit is within warranty terms and conditions.If Jotron make a decision of repairing a defective product, a written description of the claim and a Jotron RMA number, should follow the unit when returning it back to Jotron’s factory.Please be noted that un-protective electronics board MUST be packed in anti-static bag, before returning to Jotron’s factory.   Any costs related to transportation and/or workmanship linked up to the return of the product being repaired shall be covered by the customer.Jotron’s obligations during warranty replacement;• Replace defective unit, including any programming• Delivery terms: DAP Incoterms 2010 by regular freight to “Place” (Airport)Service agent’s obligations during warranty claims:• Supply replacement unit from own stock if available• If agreed, return defective unit to Jotron• Electronic units must be shipped in antistatic bags or covered with Jotron’s plastic coverSERVICE – NOT WARRANTY CLAIMService, such as testing, installation, programming, replacement, marking and battery exchange are provided by an authorized Jotron service agent. Jotron do not meet the cost for services mentioned above. Distributor or service agent should stock the most commonly needed spare parts.
29www.jotron.com www.jotron.com85525_UM_60S/GPS_ J7  MAINTENANCE7.1  EPIRB MODULE / BATTERY PACKIf the EPIRB is fitted on a vessel which requires GMDSS compliant equipment, the EPIRB shall be serviced, tested and approved as required by SOLAS regu-lation IV/15.9.2 of SOLAS 1974 as amended with, in accordance with MSC/Circ.1039 guidelines for shore-based maintenance of Satellite EPIRBs within 5 years, or by the date of battery expiry, whichever comes first.7.1.1  CHANGE OF BATTERYThe Tron 60S/GPS battery must be changed at Jotron SBM authorized work-shop to be GMDSS compliant. If your Tron 60S/GPS is not under any international or national regulations, battery can be change by authorized Jotron representatives/partners/dealers.
30www.jotron.com www.jotron.com85525_UM_60S/GPS_ J7.2  HYDROSTATIC RELEASE REPLACEMENTWARNINGOnly Jotron approved hydrostaticrelease is acceptable for use7.2.1  REPLACING THE RELEASE MECHANISM IN FB-60 BRACKET123 41.  Release and remove FB-60 top cover by removing the cotter pin (1).  WARNING!  The EPIRB can drop out of the FB-60 bracket when releasing the top cover. Remove the EPIRB from the bracket.2.  Press down the spring-loaded bracket plate and remove the hydrostatic unit by sliding it out of its locking slot. See arrow for direction.(2).3.  Check the expiry date of the new hydrostatic release mechanism (3). The date should be approximately  two years from the date of purchase.4.  Install a new hydrostatic unit by pressing down the spring loaded bracket  plate and sliding the unit into its locking slot (4). 5.  Refit the EPIRB and the FB-60 top cover. Be sure that the top cover is locked at the bottom end and that the top end are fixed at hydrostatic  release mechanism rod. Replace the cotter pin (1)
31www.jotron.com www.jotron.com85525_UM_60S/GPS_ J8  SPARE PARTS86225   Battery Pack, Tron 60S/Tron 60GPS86218   Hydrostatic Release Unit (HRU) w/Bolt FB-60 85621   FB-60, Float Free bracket86559  MB-60, Manual BracketNOTE: Keep the original satellite EPIRB packaging, since it may be needed if the EPIRB has to be shipped for servicing. UN requirements for shipping some batteries as hazardous goods require certain packaging standards and labelling9  SERVICE AGENTSPlease look at www.jotron.com for Marine Service Agents.Jotron Group subsidiary companies:Jotron UK Ltd.Crosland ParkCramlingtonNE23 1LAUnited KingdomTel  +44 1670 712000Fax  +44 1670 590265E-mail: sales@jotron.comJotron USA, Inc.10645 Richmond Avenue, Suite 170Houston, TX 77042USATel  +1 713 268 1061Fax  +1 713 268 1062E-mail: sales@jotron.comJotron Asia Pte. Ltd.Changi Logistics Center19 Loyang Way #04-26Singapore 508724Tel  +65 65426350Fax  +65 65429415E-mail: sales@jotron.com
v.JJotron ASP.O.Box 54 3281 TjodalyngNorwayTel: +47 33 13 97 00Fax: +47 33 12 67 80sales@jotron.comCONTACT INFORMATIONJotron ASP.O.Box 23 3195 SkoppumNorwayTel: +47 33 13 97 00Fax: +47 33 12 67 80sales@jotron.comJotron ASDølasletta 73408 TranbyNorwayTel: +47 32 84 53 87Fax: +47 32 84 55 30sales@jotron.comJotron UK Ltd.Crosland ParkCramlingtonNE23  1LA United KingdomTel: +44 (0) 1670 712000 Fax: +44 (0) 1670 590265sales@jotron.comJotron USA, Inc.10645 Richmond AvenueSuite 170Houston, TX 77042USATel: +1 713 268 1061Fax: +1 713 268 1062sales@jotron.comJotron Asia Pte. Ltd.19 Loyang Way Changi Logistics CentreRear Office Block 04-26Singapore 508724Tel: +65 65426350Fax: +65 65429415sales@jotron.com