Itron OWRGRD utility gas remote/automatic disconnect valve device User Manual Gas Remote Disconnect

Itron Inc utility gas remote/automatic disconnect valve device Gas Remote Disconnect

Users Manual

OpenWay® RivaGas Remote DisconnectInstallation GuideTechnicalCommunicationsknowledge to shape your future
IdentificationOpenWay® Riva Gas Remote Disconnect Installation Guide24 January 2018TDC-1759-000Copyright© 2018 Itron, Inc. All rights reserved.Confidentiality NoticeThe information contained herein is proprietary and confidential and is being providedsubject to the condition that (i) it be held in confidence except to the extent requiredotherwise by law and (ii) it will be used only for the purposes described herein. Any thirdparty that is given access to this information shall be similarly bound in writing.Trademark NoticeItron is a registered trademark of Itron, Inc.All other product names and logos in this documentation are used for identification purposesonly and may be trademarks or registered trademarks of their respective companies.SuggestionsFor more information about Itron or Itron products, see www.itron.com.If you have questions or comments about the software or hardware product, contact ItronTechnical Support Services.Contact• Email: support@itron.com• Internet: support.itron.com• Telephone Itron Technical Support North America: 1-877-487-6602For technical support contact information by region, go to www.itron.com and select yourcountry and language.
ContentsChapter 1  Important Safety and Compliance Information.............................. 1USA, FCC Part 15 compliance............................................................................................................................. 1Canada, ISED compliance.................................................................................................................................... 2RF Exposure (FCC/ISED)...................................................................................................................................... 2Electromagnetic compatibility...............................................................................................................................2Telemetering equipment classication..................................................................................................................3Intrinsic safety.......................................................................................................................................................3Lithium battery...................................................................................................................................................... 3Transportation classication................................................................................................................................. 3Modications, repairs, installation, and removal...................................................................................................3Aluminum enclosure............................................................................................................................................. 4Electrostatic discharge..........................................................................................................................................4Electrostatic ignition hazard..................................................................................................................................4Device cleaning.....................................................................................................................................................4Do Not Drop .........................................................................................................................................................4Product notication...............................................................................................................................................5Chapter 2  OpenWay Riva Gas Remote Disconnect Installation GuideOverview............................................................................................................ 6Audience............................................................................................................................................................... 6Chapter 3  About the OpenWay Riva Gas Remote Disconnect .......................7OpenWay Riva Gas Remote Disconnect models................................................................................................. 7OpenWay Riva Gas Remote Disconnect system security.................................................................................... 8Enabling OpenWay Riva Gas Remote Disconnect security....................................................................... 8Transmission mode............................................................................................................................................... 8Operational states.................................................................................................................................................8OpenWay Riva Gas Remote Disconnect functional specications...................................................................... 9OpenWay Riva Gas Remote Disconnect operational specications.................................................................... 9Related documents.............................................................................................................................................10Chapter 4  Installing the OpenWay Riva Gas Remote Disconnect................ 11Initial calibration and alignment.......................................................................................................................... 11OpenWay Riva Gas Remote Disconnect installation, commissioning, and decommissioning ......................... 12OpenWay Riva Gas Remote Disconnect accessories........................................................................................ 12Meter set installation...........................................................................................................................................13OpenWay Riva Gas Remote Disconnect valve positions.........................................................................14Installing the OpenWay Riva Gas Remote Disconnect in the pipe.......................................................... 14Installing the ood sensor........................................................................................................................ 15Mounting the ood sensor on the pipe.............................................................................................16Mounting the ood sensor on a at surface..................................................................................... 16Chapter 5  Connecting the Flood Sensor to the OpenWay Riva GasRemote Disconnect........................................................................................ 18OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 iiiProprietary and Confidential
Connecting the ood sensor inline connector to the OpenWay Riva Gas Remote Disconnect.........................18Chapter 6  OpenWay Riva Gas Remote Disconnect Programming...............20Sending OpenWay Riva Gas Remote Disconnect secure commands............................................................... 20Get Commands........................................................................................................................................20Performing a Get Commands........................................................................................................... 20Commissioning the OpenWay Riva Gas Remote Disconnect................................................................. 21Performing an OpenWay Riva Gas Remote Disconnect valve commissioning................................ 21Connecting the OpenWay Riva Gas Remote Disconnect........................................................................21Connection instructions.................................................................................................................... 21Disconnecting the OpenWay Riva Gas Remote Disconnect................................................................... 22Closing the OpenWay Riva Gas Remote Disconnect valve to disconnect service.......................... 22Decommissioning the OpenWay Riva Gas Remote Disconnect..............................................................23Decommissioning instructions..........................................................................................................23OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 ivProprietary and Confidential
Chapter 1 Important Safety and ComplianceInformationThis section provides important information for your safety and product compliance.USA, FCC Part 15 complianceThis device complies with Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation.Operation is subject to the following two conditions:• This device may not cause harmful interference.• This device must accept any interference that may cause undesirable operation.This device must be installed to provide a separation distance of at least 20 centimeters (7.9inches) from all persons to be compliant with regulatory RF exposure.USA, FCC Class B-Part 15This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses, and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiveris connected.• Consult the dealer or an experienced radio or TV technician for help.Modifications and RepairsTo ensure system performance, this device and antenna shall not be changed or modifiedwithout the express approval of Itron. Per FCC rules, unapproved modifications or operationbeyond or in conflict with these instructions for use could void the user's authority to operatethe equipment.OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 1Proprietary and Confidential
Canada, ISED complianceCompliance Statement Canada Déclaration de ConformitéThis device complies with Innovation, Scienceand Economic Development Canada (ISED)license-exempt RSS standard(s). Operation issubject to the following two conditions: (1) thisdevice may not cause interference, (2) thisdevice must accept any interference, includinginterference that may cause undesired operationof the device.Under Innovation, Science and EconomicDevelopment Canada (ISED) regulations, thisradio transmitter may only operate using anantenna of a type and maximum (or lesser) gainapproved for the transmitter by Industry Canada.To reduce potential radio interference to otherusers, the antenna type and its gain should be sochosen that the equivalent isotropically radiatedpower (e.i.r.p.) is not more than that necessaryfor successful communication.Le présent appareil est conforme aux CNRd'Industrie Canada applicables aux appareilsradio exempts de licence. L'exploitation estautorisée aux deux conditions suivantes: (1)l'appareil ne doit pas produire de brouillage, (2)l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si lebrouillage est susceptible d'en compromettre lefonctionnement.Conformément à la réglementation d'IndustrieCanada, le présent émetteur radio peutfonctionner avec une antenne d'un type et d'ungain maximal (ou inférieur) approuvé pourl'émetteur par Industrie Canada. Dans le but deréduire les risques de brouillage radioélectrique àl'intention des autres utilisateurs, il faut choisir letype d'antenne et son gain de sorte que lapuissance isotrope rayonnée équivalente (p.i.r.e.)ne dépasse pas l'intensité nécessaire àl'établissement d'une communicationsatisfaisante.RF Exposure (FCC/ISED)This equipment complies with radiation exposurelimits set forth for an uncontrolled environment.This equipment should be installed and operatedwith minimum distance 20 cm between theradiator and your body. This transmitter must notbe co-located or operating in conjunction withany other antenna or transmitter.Cet équipement est conforme aux limitesd'exposition aux radiations dans unenvironnement non contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Cet émetteurne doit pas être co-localisées ou opérant enconjonction avec tout autre antenne outransmetteur.Electromagnetic compatibilityCaution: Use only approved accessories with this equipment. All cables must behigh quality, shielded, and correctly terminated. Unapproved modifications oroperation beyond or in conflict with these use instructions may void the authority'sauthorization to operate the equipment.Important Safety and Compliance InformationOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 2Proprietary and Confidential
Telemetering equipment classificationWarning:• Telemetering equipment for use in Cl I, Div. 1, Gp. D Hazardous Location, forhazardous locations.• Temperature code: T1• Ambient temperature: -40°C < Ta < 70°C.Intrinsic safetyWarning: Substitution of components may impair intrinsic safety.Lithium batteryWarning: Follow these procedures to avoid injury to yourself or others.• The lithium battery may cause a fire or chemical burn if it is not disposed ofproperly.• Do not recharge, disassemble, heat above 100°C Celsius (212°Fahrenheit),crush, expose to water, or incinerate the lithium battery. Fire, explosion, andsevere burn hazard.• The battery used in this device may present a risk of fire or chemical burn ifmistreated.• Keep the lithium battery away from children.• Batteries must not be replaced or modified in any way.Transportation classificationThe Federal Aviation Administration prohibits operating transmitters and receivers on allcommercial aircraft. When powered, the Itron device is considered an operating transmitterand receiver and cannot be shipped by air. All product returns must be shipped by groundtransportation.Modifications, repairs, installation, and removalTo ensure system performance, this device and antenna shall not be changed or modifiedwithout the express approval of Itron. Any unauthorized modification will void the user'sauthority to operate the equipment.In the event of malfunction, all repairs should be performed by Itron. It is the responsibility ofusers requiring service to report the need for service to Itron.Important Safety and Compliance InformationOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 3Proprietary and Confidential
Aluminum enclosureWarning: This enclosure contains aluminum. Take care to avoid ignition hazard dueto impact.Electrostatic dischargeWarning: Internal circuit components can be sensitive to electrostatic discharge.Before installation, discharge electrostatic buildup by touching a metal pipe or otherearth-grounded metal object prior to touching the meter body, register housing, orItron device.Electrostatic ignition hazardWarning: Verify the area is not hazardous when installing, servicing, cleaning, ortouching the Itron device.Device cleaningWarning: Clean only with a damp cloth.Do Not DropWarning: While Itron modules are designed to withstand a drop, dropping themodule may damage the device and void the warranty.Important Safety and Compliance InformationOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 4Proprietary and Confidential
Product notificationWarning: These instructions are suggested when Itron-approved utility or installercompany-established valve installation procedures and practices are not available.• Itron does not endorse or warrant the completeness or accuracy of any third-partyvalve installation procedures or practices, unless otherwise provided in writing byItron.• Follow your company's standard operating procedures regarding the use ofpersonal protection equipment (PPE).• Adhere to guidelines issued by your company in addition to those given in thisdocument when installing or repairing valves.• This product, as of the date of manufacture, is designed and tested to conform toall governmental and industry safety standards as they may apply to themanufacturer.• The purchaser and user of this product must comply with all fire control, buildingcodes, and other safety regulations governing the application, installation,operation, and general use of this valve to avoid leaking gas hazards resultingfrom improper installation, startup, or use of this product.• To ensure safe and efficient operation of this product, Itron strongly recommendsinstallation by a qualified professional.Important Safety and Compliance InformationOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 5Proprietary and Confidential
Chapter 2 OpenWay Riva Gas RemoteDisconnect Installation Guide OverviewThis installation guide provides instructions for physically installing, commissioning,connecting, decommissioning, and physically disconnecting the OpenWay Riva GasRemote Disconnect remote-controlled valve.AudienceThis installation guide is intended for Itron personnel, third-party OpenWay Riva systeminstallers, and end-users of the OpenWay Riva Gas Remote Disconnect remotely-controlledvalve.OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 6Proprietary and Confidential
Chapter 3 About the OpenWay Riva GasRemote DisconnectThe Itron wireless OpenWay Riva Gas Remote Disconnect valve is integrated in the pipingserving OpenWay Riva networks to provide a safe secure device to stop the flow of naturalgas into a residential or commercial structure. The OpenWay Riva Gas Remote Disconnectenables system monitoring with functionality to remotely-control the natural gas supply. Anexternally connected water sensor detects flood water and supports auto-shutoff in extremeweather conditions. In the event of a disconnect due to an extreme weather condition, theOpenWay Riva Gas Remote Disconnect sends an alarm to the head-end system.Communications with the OpenWay Riva Gas Remote Disconnect device are securely sentbetween programming and monitoring devices using Itron Security Manager (ISM). ISMensures operation occurs over a secured network. The secure network allows for both openand close remote commands to facilitate operation and keep field personnel safe fromhazardous or unwelcome locations.The OpenWay Riva Gas Remote Disconnect is made up of two separate chambers: the gaschamber and the electronics chamber.• The gas chamber houses the gas valve used to shut off the flow of gas with a remotecommand. The gas valve shaft provides a visual indication of the valve position. A specialhardware tool is required to re-engage the gas flow mechanism. Re-engaging the valveto restore the flow of gas requires a qualified technician's intervention to send a wirelesscommand to enable the re-engagement and to use the valve tool to physically open thevalve. If the valve was tampered with to force the valve to remain in an open position, thesystem reports the tampering.• The electronics chamber houses the monitoring and wireless radio circuitry. Theelectronics chamber is protected with a tamper plug installed over one of the fourfasteners. If the electronics are compromised, the OpenWay Riva Gas RemoteDisconnect reports at least one tamper flag.• The valve engagement mechanism is protected by an industry standard tamper plug.The OpenWay Riva Gas Remote Disconnect can be installed in any horizontal or verticalposition that locates the mounting seal in the upright position while it facilitates gas flow inthe proper direction. Locating the mounting seal in an upright position ensures optimumbattery life and helps to keep debris from accumulating on the seal surface.OpenWay Riva Gas Remote Disconnect modelsThe OpenWay Riva Gas Remote Disconnect is available in the listed models.OpenWay Riva Gas Remote Disconnect description Itron part numberFlood sensor with 2' resistive type cable TEL-7103-002Flood sensor with 5' resistive type cable TEL-7103-003OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 7Proprietary and Confidential
OpenWay Riva Gas Remote Disconnect systemsecurityThe OpenWay Riva Gas Remote Disconnect is a component of Itron's OpenWay Rivasystem. The OpenWay Riva system enhanced security, provided by Itron Security Manager(ISM), applies to the RF communications between the collection device and the OpenWayRiva Gas Remote Disconnect. There are two fundamental security processes used in theItron Security Manager to ensure system communication confidentiality and validity.•Authentication. Authentication is the process of confirming that an artifact is genuine orvalid. Authentication in the OpenWay Riva Gas Remote Disconnect is the process ofverifying a request is from a valid source and in its original form.•Encryption. Encryption is the process of transforming information to make it unreadableto anyone who does not have a valid security key. There are two types of encryption,symmetric and asymmetric. Symmetric encryption uses a shared key to decrypt orencrypt information. Asymmetric encryption uses a private key to encrypt and a publickey to decrypt. Data transmissions over the network are protected using AES-256encryption.Enabling OpenWay Riva Gas Remote Disconnect securityWhen the OpenWay Gas Remote Disconnects ship from an Itron factory, each modulecontains utility factory keys. The presence of these utility factory keys does not enable theenhanced security. The installer enables the enhanced security at the time the OpenWayRiva Gas Remote Disconnect is deployed or at a later time using an Itron programmingdevice, Field Deployment Manager Endpoint Tools Enhanced, and programmingcommands. Initial key exchange commands are secured using the utility factory keys. Formore information about programming the OpenWay Gas Remote Disconnect for security,see the FDM Endpoint Tools Mobile Application Guide (TDC-0934).Transmission modeThe OpenWay Riva Gas Remote Disconnect operates in OpenWay Riva Network Mode andis designed to transmit 3 times a day with a 20-year battery life.An FCC license is not required to read the OpenWay Riva Gas Remote Disconnect.Operational statesThe OpenWay Riva Gas Remote Disconnect features three normal operational states.• Closed. The remote disconnect remotely-controlled valve receives a command to closefrom a network reading device. When the valve is closed, the flow of gas stops.About the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 8Proprietary and Confidential
• Commissioned. The remote disconnect remotely-controlled valve receives a command toopen from a network reading device. The valve remains in an armed state (ready to beopened) until the valve detects an open command after which the valve transitions to onopen state. The OpenWay Riva Gas Remote Disconnect remains in an armed state(ready to be physically opened) until it detects an open valve. It then transitions to theopen state.• Open. The OpenWay Riva Gas Remote Disconnect valve receives a command to openfrom a network reading device. Opening the valve requires an on-site visit to physicallyopen the valve. First, a technician uses the reading device to issue the connection (open)command. After the connection command is received, the on-site technician uses thevalve tool to open the valve. After the gas flow begins, the technician ensures the systemis operating properly and gas is flowing in the system.OpenWay Riva Gas Remote Disconnect functionalspecificationsOpenWay Riva Gas Remote Disconnect functional specifications include basicspecifications and compliance types.Functional specifications DescriptionPower source Two "A" cell lithium batteriesTamper detection Tilt, magnet, cut cable tampers, and valve criticalalarmFCC compliance Parts 1, 2, and 15 certifiedInnovation, Science and EconomicDevelopment Canada (ISED)RSS-102, RSS-247 and RSS-GEN certifiedIntrinsically safe per Telemetering Equipment for use in HazardousLocations, for Cl I, Div 1, Gp D for Haz Loc, TempCode T1, -40°C ≤ Ta ≤ +70°C.Product identification Numeric and bar coded device type and serialnumberConstruction materials Gray polycarbonate housing with encapsulatedelectronics, aluminum die cast valve bodyOpenWay Riva Gas Remote Disconnect operationalspecificationsThe OpenWay Riva Gas Remote Disconnect features these operational specifications.Operational specifications DescriptionOperating temperatures -20° to 150° F (-28.9° to +70° C)Operating humidity 5 to 95 percent relative humidityProgram frequency 908 MHzAbout the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 9Proprietary and Confidential
Operational specifications DescriptionTransmit frequency Frequency hopping spread spectrum 902.2 to 927.75MHz in the ISM bandData integrity Verified in every data messageNIM message FM modulation; all other messages are AMmodulatedRelated documentsDocument title Document part numberCustomer setup to order secured OpenWay Riva modules TDC-1748-XXXFirst article review form TDC-1749-XXXOpenWay Collection Manager Operational Guidelines  OpenWay Riva Events and Exceptions Reference Guide  Itron Mobile Radio User Guide TDC-1719-XXXItron Mobile Radio Quick Reference Guide TDC-1720-XXXGas and Telemetry Module Meter Compatibility List PUB-0117-002Gas and Telemetry Module Ordering Guide PUB-0117-001OpenWay Riva Gas Remote Disconnect Specification Sheet  Field Deployment Manager Endpoint Tools Mobile ApplicationGuideTDC-0934-XXXField Deployment Manager Mobile Application Guide (NAM) TDC-1713-XXXField Deployment Manager Field Representative's Guide TDC-0936-XXXAbout the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 10Proprietary and Confidential
Chapter 4 Installing the OpenWay Riva GasRemote DisconnectThis section describes OpenWay Riva Gas Remote Disconnect installation. Installationrequires initial calibration and alignment using an Itron handheld device loaded with FieldDeployment Manager Endpoint Tools Enhanced.Initial calibration and alignmentAt the time of deployment, the OpenWay Riva Gas Remote Disconnect requires initialcalibration and alignment. FDM Endpoint Tools Enhanced support secure installationcommissioning and verification. FDM Endpoint Tools Enhanced receives secure, signedcommands and a list of OpenWay Riva Gas Remote Disconnect reading keys for eachspecific device, if they are available. The OpenWay Riva Gas Remote Disconnect supportsFDM Endpoint Tools operation featuring two important capabilities.• Pre-fetch capabilities. FDM Endpoint Tools Enhanced obtains secure OpenWay Riva GasRemote Disconnect commands during in-office work order synchronization.• In-field commands. FDM Endpoint Tools Enhanced requests and receives commands inthe field when there is network availability and when the network has access to the head-end equipment.The OpenWay Riva Gas Remote Disconnect supports a decommissioned state. The deviceis placed into a decommissioned state prior to shipment. The device can also be placed intothe decommissioned state when it is removed from service and transported to anotherlocation.During the commissioning and decommissioning process, FDM Endpoint Tools Enhancedsupports these commands.• Secure transmission of commissioning and decommissioning commands. Also securereception of an outcome response.• Commissioning to align and calibrate the OpenWay Riva Gas Remote Disconnect.• Decommissioning to put the OpenWay Riva Gas Remote Disconnect into a state thatallows for removal or relocation.• Secure valve setting commands.The OpenWay Riva Gas Remote Disconnect supports FDM Endpoint Tools Enhancedcommands to place the valve in an open or closed state. The valve state is determined fromthe work order associated with the task. Factory security keys are injected into the deviceprior to shipment from the factory. Utility-specific security keys are supplied by the utility andare injected at the time the system is deployed. All required Itron Security Manager securecommands are obtained from FDM before the installation is verified. The following securecommands types are obtained by FDM.• CommissioningOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 11Proprietary and Confidential
• Valve control• Secure reading key commandsOpenWay Riva Gas Remote Disconnect installation,commissioning, and decommissioningThis section provides the information to physically install, connect, commission,decommission, and disconnect the OpenWay Riva Gas Remote Disconnect.Warning: These instructions are suggested when Itron-approved utility or installercompany-established valve installation procedures and practices are not available.Itron does not endorse or warrant the completeness or accuracy of any third-partyvalve installation procedures or practices, unless otherwise provided in writing byItron. Follow your company's standard operating procedures regarding the use ofpersonal protection equipment (PPE). Adhere to guidelines issued by your companyin addition to those given in this document when installing or repairing valves.This product, as of the date of manufacture, is designed and tested to conform to allgovernmental and industry safety standards as they may apply to the manufacturer.The purchaser/user of this product must comply with all fire control, building codes,and other safety regulations governing the application, installation, operation, andgeneral use of this valve to avoid leaking gas hazards resulting from improperinstallation, startup, or use of this product.To ensure safe and efficient operation of this product, Itron strongly recommendsinstallation by a qualified professional.OpenWay Riva Gas Remote Disconnect accessoriesThis section provides a list of the accessories available for the OpenWay Riva Gas RemoteDisconnect.Description Itron part numberValve tool MSC-5103-003Universal environmental cap MSC-0019-011Caution: Shield unconnected flood sensor connectors on field installed OpenWayRiva Gas Remote Disconnect devices with the protective universal environmentalcap. Do not leave flood sensor connectors exposed in field installations.Environmental caps employ multiple seals to protect connector life.Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 12Proprietary and Confidential
Meter set installationOpenWay Riva Gas Remote Disconnect deployment begins with the installation of thedevice in gas piping. The OpenWay Riva Gas Remote Disconnect is 6.5" in height andrequires clearance from the adjacent pipe, meter set components, and building materials toaccommodate that size. The device can be installed in any horizontal or vertical orientationthat facilitates gas flow in the proper direction. Locating the OpenWay Riva Gas RemoteDisconnect in one of the suggested positions ensures optimum battery life and helps keepdebris from accumulating on the seal surface. Do not mount the OpenWay Riva GasRemote Disconnect in a position that places the antenna against a structure or in foliage.OpenWay Riva Gas Remote Disconnect recommended mounting positionsNote: Install the OpenWay Riva Gas Remote Disconnect in an orientation that positions theantenna as far from walls, meters, or piping as possible. Ensure the following parameters.• A clear RF signal reaches the antenna (1).• Gas is flowing in the proper direction (the direction indicated by the arrow on theOpenWay Riva Gas Remote Disconnect).• The valve reset shaft is accessible with the valve tool (2).Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 13Proprietary and Confidential
Caution: Do not install the OpenWay Riva Gas Remote Disconnect with the gas outflow in the down position or in such a way that the antenna is against a wall or otherstructure.Remove the red shipping plugs from the inlet and outlet and vent the OpenWay RivaGas Remote Disconnect prior to installation. Keep the piping interior, regulator inlet,and regulator outlet free from dirt, chemical sealant (pipe dope), Teflon tape, or otherdebris. Materials in piping or regulator inlet or outlet create a loss of pressurecontrol. Apply pipe sealant on the male (exterior) pipe threads. Joint materials canlode in the regulator and cause a loss of pressure control. Gas must flow through thevalve body in the same direction as the arrow on the valve. Gas flowing in the wrongdirection may prevent a disconnect.OpenWay Riva Gas Remote Disconnect valve positionsThe OpenWay Riva Gas Remote Disconnect valve positions are shown in the illustrations.Valve open-valve slot horizontal Valve closed- valve slot positioned at angleNote: When the OpenWay Riva Gas Remote Disconnect valve shaft is closed, the valveshaft is in a 7:00/1:00 orientation. The valve rotates counterclockwise from open to closedbut does not rotate a full 90 degrees.Installing the OpenWay Riva Gas Remote Disconnect inthe pipe1. Select the location for the OpenWay Riva Gas Remote Disconnect and plan pipingrevisions to accommodate the gas flow direction, OpenWay Riva Gas RemoteDisconnect device body length, swing radius, and antenna clearance.Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 14Proprietary and Confidential
2. Verify the gas flow is in the direction noted by the arrow on the body of the OpenWayRiva Gas Remote Disconnect valve.3. Apply pipe sealant on the pipe.Caution: Do not leave loose tape or excess pipe sealant on the pipe connections.4. Thread the OpenWay Riva Gas Remote Disconnect onto the inlet pipe (or riser).5. Tighten the connection with a pipe wrench.6. Thread the outlet pipe into the OpenWay Riva Gas Remote Disconnect outlet.7. Tighten the connection with a pipe wrench.8. Complete meter set piping as appropriate.9. Install a tamper plug over the top tamper seal cup (if one is not already present).Installing the flood sensorWarning: Do not paint the flood sensor.Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 15Proprietary and Confidential
Mounting the flood sensor on the pipeMounting the flood sensor on a pipe requires a user-supplied band clamp large enough tosecure the sensor to the pipe.Note: Mount the flood sensor on a vertical (2) or horizontal (1) pipe using the bottom pipecradles and top and side bracket guides. The arrow on the flood sensor housing must pointup after installation.1. Position the flood sensor on the pipe using the correct pipe cradle for the pipe'sorientation.Note: Place the sensor 6 to 12 inches above the ground or floor but below the OpenWayRiva Gas Remote Disconnect.2. Place the open band clamp around the pipe and flood sensor.3. Tighten the band clamp enough to ensure the sensor cannot rotate or slip on the pipe.Mounting the flood sensor on a flat surface1. Locate the installation area on a flat surface 6 to 12" above the ground or floor but belowthe OpenWay Riva Gas Remote Disconnect.Note: The three mounting holes on the flood sensor may be used as a drilling templatefor installation.2. Secure the flood sensor to a wall or other flat surface by tightening three user-suppliedscrews through the flood sensor's mounting flanges.Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 16Proprietary and Confidential
Installing the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 17Proprietary and Confidential
Chapter 5 Connecting the Flood Sensor to theOpenWay Riva Gas Remote DisconnectThe flood sensor connects to the OpenWay Riva Gas Remote Disconnect through an inlineconnector.Connecting the flood sensor inline connector to theOpenWay Riva Gas Remote Disconnect1. Remove the protective cover from end of the flood sensor's inline connector by twistingthe protective cover tab to the left.2. Discard or recycle the protective cover.3. Align the inline connector pins with the OpenWay Riva Gas Remote Disconnectconnector pins and push the connector securely onto the remote disconnect device.OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 18Proprietary and Confidential
4. Twist the inline connector's blue tab until it aligns with the OpenWay Riva Gas RemoteDisconnect connector's tab.5. Secure a tamper seal through the connection tab's opening to complete the connection.6. Complete the installation by securing the flood sensor's cable with cable ties or wireguides.Connecting the Flood Sensor to the OpenWay Riva Gas Remote DisconnectOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 19Proprietary and Confidential
Chapter 6 OpenWay Riva Gas RemoteDisconnect ProgrammingThe OpenWay Riva Remote Gas Disconnect can be programmed and read with anFC300SR handheld computer and read with an Itron Mobile Radio connected to a user-supplied laptop. Programming the device requires Field Deployment Manager version 4.1.0.Sending OpenWay Riva Gas Remote Disconnectsecure commandsThe OpenWay Riva Gas Remote Disconnect must be programmed with the requiredsecurity parameters using a compatible programming device prior to valve commissioning.For complete programming information, see the Field Deployment Manger MobileApplication Guide (TDC-1713-XXX [XXX designates the application guide's revision level]).Get CommandsPerforming a Get Commands is required using FDM Endpoint Tools allows before the usercan initiate secure communications between the programming device and the OpenWayRiva Gas Remote Disconnect. If the programming device is the FC300SR, the device mustbe docked in the cradle to communicate with the server before a Get Commands can beperformed.Important: Shared key files must be installed on the FDM and ISM servers.Performing a Get Commands1. Open FDM.2. Click the tools icon on the upper left corner.3. Select Endpoint Tools.4. Click the computer icon in the upper left corner.5. Select Get Commands.6. Enter the OpenWay Riva Gas Remote Disconnect device ID.7. From the Device Type drop-down list, select OWR-GRD.8. Click the + icon.The Device ID is added to the Device Type list.Note: Several devices may be added to the Device Type list prior to communicating withthe server.9. Click OK.OpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 20Proprietary and Confidential
The programming device communicates with the server. The red X next to the Device IDchanges to a secure lock symbol.10. Select the communication type (OpenWay Riva Network).11. Select Program Endpoint.12. Enter the OpenWay Riva Gas Remote Disconnect Endpoint ID.13. Click Next.A screen appears showing the programming parameters.14. Click Next.The OpenWay Riva Gas Remote Disconnect is ready to commission.Commissioning the OpenWay Riva Gas RemoteDisconnectWarning: COMMISSIONING MUST TAKE PLACE FOLLOWING THE FINALINSTALLATION. Commissioning is dependent on site-specific configuration.Continue the OpenWay Riva Gas Remote Disconnect deployment by commissioning thevalve. Commissioning requires an Itron programming or reading device loaded with FDMEndpoint Tools Enhanced.Performing an OpenWay Riva Gas Remote Disconnect valvecommissioning1. Using FDM Endpoint Tools Enhanced, select number 4, Commission.2. Enter the OpenWay Riva Gas Remote Disconnect Device ID.3. Select Next.Note: The ISM security keys are injected during the commissioning process to enableOpenWay Riva Gas Remote Disconnect enhanced security.Connecting the OpenWay Riva Gas Remote DisconnectContinue the OpenWay Riva Gas Remote Disconnect deployment by connecting the device.This process prepares the valve for opening by a qualified installer or technician.Caution: If the OpenWay Riva Gas Remote Disconnect valve is opened too soon,you must send a Disconnect Service command followed by a new ConnectService command.Connection instructions1. Using the programming device loaded with FDM Endpoint Tools Enhanced, selectnumber 2, Connect Service.OpenWay Riva Gas Remote Disconnect ProgrammingOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 21Proprietary and Confidential
2. Click Next.3. Enter the OpenWay Riva Gas Remote Disconnect device ID.4. Click Next.Caution: A Warning appears to remind the service technician to light the pilotsafter the valve is opened. You must wait until the programming device confirmsthe valve is ready to be opened. If an attempt is made to open the valve beforethe programming device confirms a valve ready state, the valve will return a failedstatus and initiate a tamper event.5. Using the valve tool, turn the valve shaft to lock the valve into the open position.Important: Turn the valve tool until you hear a click indicating the valve locked intoposition. In the event the valve operation is not confirmed, an error message appears:Result of operation is inconclusive. The endpoint was not found.Disconnecting the OpenWay Riva Gas Remote DisconnectIn the event the gas service is being disconnected, follow these instructions to close theOpenWay Riva Gas Remote Disconnect valve.Closing the OpenWay Riva Gas Remote Disconnect valve todisconnect service1. In FDM Enpoint Tools Enhanced, select number 3, Disconnect Service.2. Enter the OpenWay Riva Gas Remote Disconnect device ID.3. Click Next.Note: A warning appears: You are turning off the gas supply.4. Click Next.OpenWay Riva Gas Remote Disconnect ProgrammingOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 22Proprietary and Confidential
Note: A confirmation appears indicating the valve is closed. If the valve does not confirma closed status, an error screen will appear. Repeat the process. If the valve does notconfirm a closed status after the second attempt, contact Itron Support Services for help.Decommissioning the OpenWay Riva Gas RemoteDisconnectIn the event the OpenWay Riva Gas Remote Disconnect will be removed from service, thedevice must first be decommissioned.Warning: Prior to decommissioning the OpenWay Riva Gas Remote Disconnect,verify the gas supply is turned off. Decommissioning the OpenWay Riva GasRemote Disconnect returns the device to Factory Ship Mode with security enabled.To recommission the OpenWay Riva Gas Remote Disconnect, the user must get theproper signed commands from FDM and ISM to recommission the device.Performing a Check ERT with FDM Endpoint Tools Enhanced will not recommissionthe OpenWay Riva Gas Disconnect.Decommissioning instructions1. Select number 5, Decommission in FDM Endpoint Tools Enhanced.2. Click Next.3. Enter the OpenWay Riva Gas Remote Disconnect device ID.4. Click Next.A window displays confirming the OpenWay Riva Gas Remote Disconnect wassuccessfully decommissioned.OpenWay Riva Gas Remote Disconnect ProgrammingOpenWay Riva Gas Remote Disconnect Installation Guide TDC-1759-000 23Proprietary and Confidential

Navigation menu