Itron NIC441 NIC Module for Network Relay Points User Manual Labeling Requirements

Silver Spring Networks NIC Module for Network Relay Points Labeling Requirements

Labeling Requirements

Silver Spring Networks555 Broadway StreetRedwood City, CA 94063www.silverspringnet.comNetwork Relay Point (NRP) NIC 440 Labeling Product Requirements   24 March 2014    Silver Spring Networks 1Network Relay Point (NRP) NIC 440 Labeling Product Requirements
Customer SupportTelephone Hours EmailToll free within the US and Canada:1-888-SSN-9876(1-888-776-9876)Non-toll-free: 1-650-839-42985:00 AM - 6:00 PM US Pacific Timesupport@silverspringnet.comIn Australia:1300 706 7699:00 AM - 9:00 PMAustralia Eastern Timeaus-support@silverspringnet.comContact us on the Web: http://www.silverspringnet.com/services/customer-support/NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 2NRP NIC 440 Product Requirements    Confidential Information of Silver Spring Networks®, Inc., provided under nondisclosure obligations.Copyright © 2014 Silver Spring Networks, Inc. All rights reserved.The following are registered trademarks of Silver Spring Networks, Inc: the Silver Spring Networks name and logo, CustomerIQ®, GreenBox®, GridScape®, UtilityIQ®, UtilOS®.The following are trademarks of Silver Spring Networks, Inc: Altogether Brilliant™, Connect to the Energy Network™, Connect to The Everything Network™, EnergyIQ™, GreenIQ™, MForm™, MicroAP™, Micromesh™, NetworkIQ™, SilverLink™, SSNsor™, The Everything Network™, The Internet of Important Things™.All other company and product names are used for identification purposes only and may be registered trademarks, trademarks, or service marks of their respective owners.Please consider the environment before printing this document.
Network Relay Point (NRP) NIC 440 Labeling Product Requirements 24 March 2014    Silver Spring Networks 1Network Relay Point (NRP) NIC 440 Labeling Product Requirements  ContentsContents 1. About the Silver Spring Networks Network Relay Point (NRP) NIC . . . . . . . . . . . . . . . . .  2References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2NIC Address Labeling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2NIC Labeling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32. FCC and Industry Canada Government Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Exigences d'Industrie Canada  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6FCC and Industry Canada Guidelines for Devices Containing a Transmitter Module . . . . . . . . . . . . .  6NIC 440 External Antenna Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8General Electrical Safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8Personal Protective Equipment (PPE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9Fall Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9Shock Accident First Aid. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 2NRP NIC 440 Product Requirements   1 About the Silver Spring Networks Network Relay Point (NRP) NIC1About the Silver Spring Networks Network Relay Point (NRP) NICTheNetworkRelayPoint(NRP)NICisanetworkinterfacecard(NIC)thatenablesmachine‐to‐machinecommunicationover900MHzand2.4GHzISMbands.TheNICalsoincorporatesan802.15.4‐compliantZigBee®radioforHomeAreaNetworking(HAN).ReferencesGuidelinesfor64‐bitGlobalIdentifier(EUI‐64™)RegistrationAuthority,IEEEStandardsAssociation.NIC Address LabelingForradioidentification,thestreetlightequipmentshallhaveanauxiliarylabelcontainingtheSilverSpringNetworksNICaddresspresentedintext(16alphanumericdigits)andbarcodeformats.•BarCodeType=Code3of9•BarCodeFontSize=unknown•FontType=unknown•FontSize=unknown•BarCodeLabelDimensions=1.0ʺx1.5ʺ•BarCodeMaterialType=StaticDissipativePolyimideFigure 1.  Silver Spring Network Relay Point (NRP) NICTop view Bottom view
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 3NRP NIC 440 Product Requirements   1 About the Silver Spring Networks Network Relay Point (NRP) NICFigure2showsanexampleoftheNICaddresslabel,whichisconsistentwithFCCrequirementssetforthinChapter2FCCandIndustryCanadaGovernmentGuidelines,andcontainstheSilverSpringNetworkscorporatenameandNICEUI‐64address.NIC Labeling TheNetworkRelayPoint(NRP)NIChasalabelrelevanttoNRPfinalassemblyandRMA:theFCCandPartNumberlabelandtheSilverSpringNICaddresslabel.BothlabelsarelocatedonthebottomsideoftheNICPCA.TheFCCIDlabelis1ʺx.375ʺinches(2.5x1cm).Figure3showsanexampleoftheFCCIDlabelfoundontheNRPNICFigure 2.  Example of NIC address label for NIC 440Figure 3.  Sample FCC ID label for the NRP NICSilver Spring Networks1234567890123456Contains: FCC ID: OWS-NIC441IC: 5975A-NIC441
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 4NRP NIC 440 Product Requirements   1 About the Silver Spring Networks Network Relay Point (NRP) NICFigure4showstheplacementofthelabels.Figure 4.  Label locations on the Silver Spring NRP NICSilver Spring part numberMAC addressCatalog number Model number FCC ID IC Certification
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 5NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government Guidelines2FCC and Industry Canada Government GuidelinesSilver Spring Networks NRP NICFCC ID: OWS-NIC441IC: 5975A-NIC441RequirementsTheNetworkRelayPoint(NRP)networkinterfacecard(NIC)isREQUIREDtobeprofessionallyinstalledbyaproperlytrainedtechnician.Improperinstallationcouldvoidtheuser’sauthoritytooperatetheequipment.ThisdevicecomplieswithPart15oftheFCCRulesandIndustryCanadalicence‐exemptRSSstandard(s).Operationissubjecttothefollowingtwoconditions:1. Thisdevicemaynotcauseharmfulinterference,and2. Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.Theantennaofthistransmittermustnotbeco‐locatedoroperatinginconjunctionwithanyotherantennaortransmitter.Thedeviceshouldbeinstalledsothatpeoplewillnotcomewithin20cm(8in.)oftheantenna.Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatetheequipment.ThisequipmenthasbeentestedandfoundtocomplywithPart15oftheFCCRules.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergy,andifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception(whichcanbedeterminedbyturningtheequipmentoffandon),theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:•Reorientorrelocatethereceivingantenna.•Increasetheseparationbetweentheequipmentandreceiver.•Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.•Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 6NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government GuidelinesExigences d'Industrie CanadaLacarted’interfaceréseau(NIC)SilverSpringNetworkRelayPoint(NRP)DOITêtreinstalléeparuntechnicienayantreçuuneformationadéquate.Uneinstallationincorrectepeutannulerl’autorisationdel’utilisateuràseservirdel’équipement.LeprésentappareilestconformeauxCNRd’IndustrieCanadaapplicablesauxappareilsradioexemptsdelicence.L’exploitationestautoriséeauxdeuxconditionssuivantes:(1)l’appareilnedoitpasproduiredebrouillage,et(2)l’utilisateurdel’appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesilebrouillageestsusceptibled’encompromettrelefonctionnement.L’antennedecetémetteurnedoitpassetrouveràproximitédeoufonctionnerenassociationavecuneautreantenneouunautreémetteur.Ledispositifdoitêtreinstallédemanièreàempêchertoutepersonnedeseretrouveràmoinsde20cm(8po)del’antenne.Leschangementsoumodificationsapportéssansl’approbationexpressedel’autoritéresponsabledelaconformitépourrontentraînerl’annulationdel’autorisationd’utilisationdecetéquipement.FCC and Industry Canada Guidelines for Devices Containing a Transmitter Module ThefollowingisanextractfromFCCPART15UNLICENSEDMODULARTRANSMITTERAPPROVAL,DA00‐1407,Released:June26,2000,Section6describinglabelingrequirementsfordevicescontainingamodulartransmitter.Section6.ThemodulartransmittermustbelabeledwithitsownFCCIDnumber,and,iftheFCCIDisnotvisiblewhenthemoduleisinstalledinsideanotherdevice,thentheoutsideofthedeviceintowhichthemoduleisinstalledmustalsodisplayalabelreferringtotheenclosedmodule.Thisexteriorlabelcanusewordingsuchasthefollowing:“ContainsTransmitterModuleFCCID:XYZMODEL1”or“ContainsFCCID:XYZMODEL1.”Anysimilarwordingthatexpressesthesamemeaningmaybeused.TheGranteemayeitherprovidesuchalabel,anexampleofwhichmustbeincludedintheapplicationforequipmentauthorization,or,mustprovideadequateinstructionsalongwiththemodulewhichexplainthisrequirement.Inthelattercase,acopyoftheseinstructionsmustbeincludedintheapplicationforequipmentauthorization.ThefollowingisanextractfromRSS‐GEN,GeneralRequirementsandInformationfortheCertificationofRadioApparatus,Section3.2.1,describinglabelingrequirementsforahostdeviceintegratingaradiomodule.Thehostdeviceshallbeproperlylabelledtoidentifythemoduleswithinthehostdevice.TheIndustryCanadacertificationlabelofamoduleshallbeclearlyvisibleatalltimeswheninstalledinthehostdevice,otherwisethehostdevicemustbelabelledtodisplaytheIndustryCanadacertificationnumberofthemodule,precededbythewords“Containstransmittermodule”,ortheword“Contains”,orsimilarwordingexpressingthesamemeaning,asfollows:
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 7NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government GuidelinesContainstransmittermoduleIC:XXXXXX‐YYYYYYYYYYYwhereXXXXXX‐YYYYYYYYYYYisthemoduleʹscertificationnumber.L’extraitsuivantprovientduCahierdeschargessurlesnormesradioélectriques(CNR);exigencesgénéralesetinformationrelativesàlacertificationdesappareilsradio,section3.2.1,etdécritlesexigencesenmatièred’étiquetagepourundispositifhôteintégrantunmoduleradio.Ledispositifhôtedoitêtrecorrectementétiquetéafind’identifierlesmodulesqu’ilcomprend.L’étiquettedecertificationIndustrieCanadad’unmoduledoittoujoursêtrebienvisiblelorsdel’installationsurundispositifhôte.Danslecascontraire,ledispositifhôtedoitêtreétiquetédefaçonàafficherlenumérodecertificationIndustrieCanadadumodule,précédédel’expression«Containstransmittermodule»oudumot«Contains»,oud’uneformulationsimilaireayantlamêmesignification.Parexemple:ContainstransmittermoduleIC:XXXXXX‐YYYYYYYYYYYoùXXXXXX‐YYYYYYYYYYYreprésentelenumérodecertificationdumodule.Theapplicantforequipmentcertificationofthemoduleshallprovidewitheachunitofthemoduleeitheralabelsuchasdescribedabove,oranexplanationandinstructionstotheuserastothehostdevicelabellingrequirements.NIC 440 External Antenna IntegrationThisradiotransmitter5975A‐NIC441hasbeenapprovedbyIndustryCanadatooperatewiththeantennatypeslistedbelowwiththemaximumpermissiblegainandrequiredantennaimpedanceforeachantennatypeindicated.Antennatypesnotincludedinthislist,havingagaingreaterthanthemaximumgainindicatedforthattype,arestrictlyprohibitedforusewiththisdevice.•Omnidirectionalantennas:3dBiat900MHz,4dBiat2.4GHzLeprésentémetteurradio(identifierledispositifparsonnumérodecertificationousonnumérodemodèles’ilfaitpartiedumatérieldecatégorieI)aétéapprouvéparIndustrieCanadapourfonctionneraveclestypesd’antenneénumérésci‐dessousetayantungainadmissiblemaximaletl’impédancerequisepourchaquetyped’antenne.Lestypesd’antennenoninclusdanscetteliste,oudontlegainestsupérieuraugainmaximalindiqué,sontstrictementinterditspourl’exploitationdel’émetteur.•Antennesomnidirectionnelles:3dBià900MHz,4dBià2.4GHzFigure 5.  Sample FCC ID label for devices containing an NRP NIC (NIC 440) Contains FCC ID: OWS-NIC441 IC: 5975A-NIC441
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 8NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government GuidelinesUnderIndustryCanadaregulations,thisradiotransmittermayonlyoperateusinganantennaofatypeandmaximum(orlesser)gainapprovedforthetransmitterbyIndustryCanada.Toreducepotentialradiointerferencetootherusers,theantennatypeanditsgainshouldbesochosenthattheequivalentisotropicallyradiatedpower(e.i.r.p.)isnotmorethanthatnecessaryforsuccessfulcommunication.Conformémentàlaréglementationd’IndustrieCanada,leprésentémetteurradiopeutfonctionneravecuneantenned’untypeetd’ungainmaximal(ouinférieur)approuvépourl’émetteurparIndustrieCanada.Danslebutderéduirelesrisquesdebrouillageradioélectriqueàl’intentiondesautresutilisateurs,ilfautchoisirletyped’antenneetsongaindesortequelapuissanceisotroperayonnéeéquivalente(p.i.r.e.)nedépassepasl’intensiténécessaireàl’établissementd’unecommunicationsatisfaisante.Safety InformationCarefulplanningofeveryjobisessential.Nothingshouldbetakenforgranted.Donottakechances!•Readandfollowallapprovedpoliciesandproceduresprovidedbyyouremployerassociatedwiththeproceduresinthismanual.•Theproceduresinthismanualmustonlybeperformedbyqualifiedworkersinaccordancewithlocalutilitysafetypractices,utilityrequirements,andapplicableOSHAandNFPAstandards.•Theinformationcontainedinthisdocumentisintendedtoaidqualifiedpersonnel,andisnotareplacementforthepropertrainingrequiredtomakeapersonqualified.•SilverSpringNetworksassumesnoliabilityforthecustomerʹsfailuretofollowthesesafetyguidelines.General Electrical Safety•Performtheproceduresinthismanualinaccordancewithapplicableworkplacestandardsestablishedbythefollowingagencies:— OccupationalSafetyandHealthAct(OSHA).—TheNationalElectricalCodepublishedbytheNationalFireProtectionAssociation(NFPA‐70).—NationalElectricalManufacturersAssociation(NEMA).— ElectronicsIndustriesAssociation(EIA).—InsulatedPowerCableEngineersAssociation(IPCEA).WARNING: Severe shock and explosion hazard! Touching energized parts can result in massive equipment damage, and severe injury or death. Short-circuiting energized parts will result in blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may result in other injuries. Observe the following safety guidelines.
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 9NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government Guidelines•AmericanNationalStandardsInstitute(ANSI).Wheneverpossible,de‐energizeallcircuitsorequipmentbeforeworkingonthem.•Maintainaminimumclearanceof10feet(3meters)betweenlinepotentialandallunqualifiedpersonsatalltimes.•Keepunauthorizedpeopleoutoftheworkarea.Beespeciallycautiousofchildren,whotendtobedrawntoworkactivity.•DeterminingifacircuitisOFFcanbedifficultinsomeinstances.Checkforcircuitvoltagewithanappropriatevoltmeterbeforeworkingonequipmentpresumedtohavebeende‐energized.Tiebreakers,doublethrowdisconnectswitches,automatictransferswitchesandemergencygeneratorscansupplypowerthroughanalternatecircuitorfromanothersource.•120Vcurrentcanbejustalethalashighervoltagesbecausecurrentflowthroughabodydependsuponthebodyʹsresistance.•Donottrustinsulationand/orweatherproofingonawireasprotectionfromshock.•Useelectricallyinsulatedtools.Inspectportableelectricalequipmentortoolsfordefectsandremoveanydefectivedevicesfromserviceimmediately.AllportableelectricalequipmentmusthaveGroundFaultCircuitInterrupter(GFCI)protection.•Selecttherighttoolforthejob.Usetoolsproperly.Keeptoolsingoodworkingorder.•Makesuretheworkareaisfreeofanyflammablematerial.Flammablevaporscanbeignitedbyanarcflash.•Keeptheworkareacleananddry.Clutteredworkareascauseaccidentsandinjuries.•Providegoodlightingintheworkarea.Youcannotworksafelyifyoucannotseewhatyouaredoing.•Reportunsafeconditionsordefectiveequipmenttoyourimmediatesupervisor.•Handlematerialcarefully.Liftandcarryproperly.Personal Protective Equipment (PPE)•AlwayswearPersonalProtectiveEquipment(PPE),inaccordancewithOSHAandANSIstandards.•Weareyeprotectionandelectricallyinsulatedgloves.TestglovesinaccordancewithANSIstandardsbeforeuse.Donotuseglovesthatdonotpassappropriatetestprocedures.•Wearprotectiveclothingsuchaslongsleeveshirtsandlongpantsmadeofflameresistantmaterials.•Removealljewelry.•Donotpassanyobjectstoorfromotherpersonsnotprotectedbyinsulatingplatformsortested,electricallyinsulatedgloves.Fall Protection Whenperformingworkatanyelevation:
NRP NIC 440 Product Requirements    24 March 2014    Silver Spring Networks 10NRP NIC 440 Product Requirements   2 FCC and Industry Canada Government Guidelines•Alwaysuseafallprotectionsystem,inaccordancewithOSHAstandards,wheneverperformingworkatanyelevation.•Neveruseconductors,guywires,pins,orcross‐armbraces,etc.tosupportyourweight.•Wheneverusingaerialliftdevicessuchashoists,man‐lifts,vehicle‐mountedworkplatformsandoverheadlifts,readandfollowthemanufacturer’sguidelinesforsafeandproperoperation.•Useladdersandscaffoldingonlyinaccordancewiththemanufacturer’sguidelinesand/oraccordingtoOSHAstandards.•Onlyuseladdersmadeofnon‐metallic,non‐conductivematerial.Theyshouldbethepropersizeandtypefortheworkintended.Inspectladdersforwearandbreakage.Removeanyoil,grease,orotherslipperymaterials.•Donotsettheladderattoosteeportooshallowofanangle.Aruleofthumbistostanderectwithyourtoesagainstthebottomrailsoftheladder,withyourarmsextendedstraightout.Ifyoucansetyourpalmsontopoftherungthatisateyelevel,theladdershouldbeattheproperangle.Ifaladderanglelabelisprovided,followitsrecommendations.•Iftheladderistoremaininplaceforanextendedperiod,secureitatthetop.Thesupportpointatthetopoftheladdershouldbeatleast24inches(60centimeters)widetomaintainsupportintheeventofsidewaysmovement.Forjobsofshortduration,haveafellowworkersupporttheladderatthebase.•Evaluatealltaskstobeperformedfromaladderforpotentialfallhazards,suchascomplextasksorsituationsthatrequireleaningfromthesideoftheladder.•Theuseofscaffoldingoraworkplatformshouldbeconsideredasanalternativesolutioninsuchcases.Shock Accident First Aid •Donottouchthevictimwithyourbarehands;usesomethingnon‐conductivetoseparatethevictimfromtheenergysource.•Callforemergencymedicalhelpimmediately.Keepthevictimlyingdown,warm,andcomfortableuntilhelparrives.Avoidmovingthevictimincaseofinjurytoneckorback.Positionanunconsciousvictimonasidetoletfluidsdrain.•Checkthevictim’sbreathingandheartbeat.Ifproperlytrained,applymouth‐to‐mouthresuscitationand/orCPRifnecessary.•Removeconstrictingitemsfromthevictim,suchasshoes,belts,jewelry,andtightcollars;theycouldcutoffcirculationifthevictimexperiencesswelling.•Applywaterorsalineforafewminutestoanyburnsuntiltheskinreturnstonormaltemperature.Donotattempttoremoveclothingthatisstucktoaburn.Ifpossible,elevateburnedareastoreduceswelling.•Makesurethevictimreceivesprofessionalmedicalattention,eveniftheyfeelfine.Electricshockcancauseheartfailurehoursaftertheshockisreceived.

Navigation menu