Itron 100WD AMR transceiver decive for utility meters User Manual Users Guide 3

Itron Inc AMR transceiver decive for utility meters Users Guide 3

Users Guide 3

Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 30  Proprietary and Confidential    To install the Leak Sensor on a pipe (up to 2 1/2-inch OD) 1. Select a Leak Sensor mounting  location  within  5 feet of the ERT module.   Note  Leak Sensor mounting  orientation  is not critical.  Orient  the sensor to best accommodate your installation.  The most important installation  practice is to fasten the sensor securely to the pipe.  Caution  Mount the Leak Sensor on the water input side of the meter. Failure to follow  this mounting requirement could result in errors in the leak detection data. Installation  requires Itron mounting  hardware. Repair costs and service charges  relating  to the use on non-compliant mounting hardware will be charged to the customer. Contract Itron Support for more information. 2.  Insert the mounting  plate screws into the holes  on the Leak Sensor's curved surface.  3. Secure the mounting  plate to the Leak Sensor.    4. Verify  the pipe’s  mounting  surface is free from dirt and debris. Place the curved surface of the LS against the pipe.  Caution  Do not mount the Leak Sensor on a pipe coupler, joint, or nut.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 31   Proprietary and Confidential     5. Insert the U-bolt around the pipe and into the holes  in the plate/Leak  Sensor assembly. Secure the U-bolt with the wing nuts. Tighten the wing  nuts until  snug (to a minimum  of 5-inch pounds) to prevent device rotation on the pipe. After the second wing nut is tightened, check the Leak Sensor to verify the device is snug. If the sensor moves, tighten  the wing  nuts until  there is no movement.   Caution  Do not tighten  the Leak Sensor to more than 20 inch-pounds. Over-tightening  could damage the Leak Sensor housing  and/or the pipe.
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 32   Proprietary and Confidential     The optional  900 MHz remote mount antenna provides  increased  RF range coverage  for the listed  mobile applications  where the meters are located deep in a pit boxes. This section  provides antenna mounting  instructions  through a pit lid  and the instructions  to connect the optional  antenna to the ERT module.  Caution  Only remote  antenna ERT  modules  can be used with  the remote antenna. See the following table for 100W and 100WP remote antenna ERT models.  100W and 100WP ERT Module Models for use with Remote Antennas  100W and 100WP ERT Module  Description Itron Part Number 100W + encoder ERT  module with  optional remote antenna  and   register integral  connectors ERW-1300-202 100W+ encoder ERT module with  optional remote antenna  and  register integral connectors, ISM ERW-1300-302 100W encoder ERT  module  with  optional remote antenna,  Leak  Sensor, and  register integral connectors ERW-1300-203 100W+ encoder ERT module with  optional remote antenna,  Leak  Sensor, and register integral connectors, ISM ERW-1300-303 100W 5-ft. flying  leads  encoder ERT  module with  optional remote antenna  integral  connector ERW-1300-205 100W+ 5-ft. flying  leads encoder ERT module with  optional remote antenna integral connector, ISM ERW-1300-305 100W 5-ft. flying leads encoder ERT module with optional remote antenna and Leak Sensor connectors ERW-1300-206 100W+ 5-ft. flying  leads encoder ERT module with  optional remote antenna and Leak Sensor connectors, ISM ERW-1300-306 100W 20 in.  flying  leads  encoder ERT  module with  optional remote antenna  integral  connector ERW-1300-217 100W+ 20 in.  flying  leads encoder ERT module with  optional remote antenna  integral connector, ISM ERW-1300-317 100WP 20 in. flying  leads encoder ERT  module  with  optional  remote antenna   and  Leak  Sensor integral connectors ERW-1300-218 100WP+ 20 in. flying  leads  encoder ERT module with optional remote antenna  and Leak Sensor integral connectors, ISM ERW-1300-318 100WP  pulser ERT  module with  optional remote antenna and register integral connectors ERW-1300-208 100WP+ pulser ERT module with  optional remote antenna  and register integral connectors, ISM ERW-1300-308 100WP pulser ERT  module  with  optional  remote antenna,  Leak  Sensor, and  register integral connectors ERW-1300-209 100WP+ pulser ERT module with  optional remote antenna,  Leak  Sensor, and  register integral connectors, ISM ERW-1300-309 100WP 5-ft. flying leads pulser ERT module with optional remote antenna and Leak Sensor integral connectors ERW-1300-212 100WP+ 5-ft. flying leads  pulser ERT  module with  optional remote antenna and Leak Sensor integral connectors, ISM ERW-1300-312 100WP 20 in. flying leads pulser ERT module with optional remote antenna integral connector ERW-1300-219 100WP +20 in. flying leads pulser ERT module with  optional remote antenna  integral connector, ISM ERW-1300-319 100WP  20 in. flying leads pulser ERT  module with  optional remote antenna  and Leak Sensor integral connectors ERW-1300-220 100WP + 20 in. flying leads pulser ERT module with optional remote antenna  and Leak Sensor integral connectors, ISM ERW-1300-320 CHAPTER 5  Optional Direct Connect Remote Antenna Installation
Optional Direct Connect Remote Antenna  Installation   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 33   Proprietary and Confidential           Industry Canada Conformity   This  radio transmitter (IC:864D-100WC) has been approved  by Industry  Canada  to operate with the antenna  types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna  types not included in this list, having  a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.  Le présent émetteur radio (IC: 864D-100WC) a été approuvé  par Industrie Canada  pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque  type d'antenne.  Les types d'antenne non inclus dans  cette liste, ou  dont le gain  est supérieur au  gain  maximal  indiqué,  sont strictement interdits pour l'exploitation de l'émetteur.  Specification  Part number CFG-0900-003 Gain 2 dBi Horizontal beamwidth Omni-directional Impedance 50 ohms Termination  Proprietary  Installing the Remote Antenna Metal lids on water pit boxes require a through-lid  solution  for optimal ERT module radio performance. The remote antenna is designed  to fit in a pit lid hole with a diameter of 3/4-inch and lid thicknesses from 1/4-inch to 1-3/4-inch.   Caution  Remove  cable or twist  ties from the antenna cable to prevent damage  to the ERT module or antenna.
Optional Direct Connect Remote Antenna  Installation   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 34  Proprietary and Confidential     To install the remote antenna through a pit lid 1. Thread the remote antenna connector and cable  through the pit lid hole. Verify  the antenna's convex surface is on the top of the pit lid. (These instructions  show a simulated  pit lid  material.)     2. Insert the antenna connector through the rectangular  opening  in the threaded collar.     3. Turn the threaded collar  until  it is tight  against  bottom of the pit lid.          To connect the remote  antenna to the ERT module 1. Align  the connector pins with the top, red connector on the ERT module. The illustration  shows a 3-port ERT module  connection.
Optional Direct Connect Remote Antenna  Installation   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 35   Proprietary and Confidential         2. Push in the antenna connector to complete  the connection. The illustration  shows a two-port ERT module connection.    3. Turn the connector lock ring to the right  to secure the connection. Caution  Turn the connector  lock-ring  only. Do not twist the completed  connection. Twisting  the connection could damage the ERT module or antenna connector pins.  4. Follow the Rod Mount Installation on page 14 or Wall Mount Installation on page 17 instructions to mount the ERT module.
Optional Direct Connect Remote Antenna  Installation   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 36  Proprietary and Confidential    Remote antenna installation  is complete.