Users Manual Section 1

   Natural Gas Solutions 100G Datalogging Installation Guide - Direct Mount
 100G Datalogging Installation Guide - Direct Mount ii  Identification 100G Datalogging Installation Guide - Direct Mount  03/6/2009   TDC-0823-000     Endpoint Part Numbers: 100G Endpoint: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008                                         100G Datalogging Endpoint: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008    Copyright © 2009 Itron, Inc. All rights reserved.  Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118  Compliance Statement  This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: • This device may not cause harmful interference. • This device must accept any interference that may cause undesirable operation. This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.   Compliance Statement  This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following conditions: • This device may not cause interference. • This device must accept any interference that may cause undesired operation of the device.  Compliance Statement  This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.    Trademark Notice Itron and Endpoint-Link are registered trademarks of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.   Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support:   Contact • Mail: Itron, Inc. Attention: Customer Care, 2111 N Molter Road, Liberty Lake, WA 99019  • Internet: www.itron.com • E-mail: support@itron.com • Phone: 1 800 635 8725       WARNING! Follow these procedures to avoid injury to yourself or others: •The lithium battery may cause a fire or chemical burn if it is not disposed of properly. •Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), or incinerate    the lithium battery. •Keep the lithium battery away from children. •Replace the lithium battery only with batteries meeting Itron specifications. Any other battery   may cause a fire or explosion.  WARNING!  Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.  WARNING!  To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.  WARNING!  Substitution of components may impair intrinsic safety.
 100G Datalogging Installation Guide - Direct Mount iii  Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging Endpoint is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.  Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment.   Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
 100G Datalogging Installation Guide - Direct Mount iv  Document Conventions The following documentation conventions are used:  CAUTION!   This type of note warns the user that failure to heed the information in the note could result in loss of data. Be sure to carefully read a CAUTION note and heed the advice/instructions.                       WARNING!  This type of note is used to warn of potential physical harm to the user or hardware. It is critical that you pay strict attention to WARNING notes, read the information carefully, and heed the advice, instructions.  This type of note provides the user with extra hints/tips to make a task easier to perform or a concept easier to understand.  This type of note supplies generic information to the user. The information could be ignored and the user could still continue with a task without suffering any adverse consequences.
 100G Datalogging Installation Guide - Direct Mount  v  Chapter 1 100G Datalogging Gas Endpoint ................................................................ 1 Transmission Modes ........................................................................................................................... 1 Specifications ...................................................................................................................................... 2 Related Documents .................................................................................................................. 2 Meter Compatibility List ....................................................................................................................... 2 Installation Prerequisites ..................................................................................................................... 8 Chapter 2 Elster American Meter Installation ........................................................... 11 Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 16 Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter ................. 18 Chapter 3 Sensus/Rockwell Meter Installation ......................................................... 21 Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 25 Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter .............................. 27 Chapter 4 Itron/Actaris Meter Installation ................................................................. 31 Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 34 Attaching the 100G Datalogging Gas Endpoint Assembly to the Itron/Actaris Meter ....................... 36 Attaching the 100G Datalogging Gas Endpoint Assembly to Flat-faced Itron/Actaris Meters 39 Securing Brass Meter Tags to Flat-faced Meters ................................................................... 43 Chapter 5 National/Lancaster Meter Installation ...................................................... 47 Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 53 Attaching the 100G Datalogging Gas Endpoint Assembly to the National/Lancaster Meter ............ 55 Chapter 6 Elster American and Itron Actaris Commercial Meter Installation ........ 57 Removing the Index/ Index Assembly from the Meter ...................................................................... 58 Programming the 100G Datalogging Commercial Gas Endpoint ..................................................... 60 Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris Commercial Meter 67 Chapter 7 Sensus/Rockwell Commercial Meter Installation ................................... 73 Removing the Index/ Index Assembly from the Meter ...................................................................... 73 Programming the 100G Datalogging Gas Endpoint .......................................................................... 74 Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphragm Meter ............................................................................................................................... 76 Contents
Contents  vi 100G Datalogging Installation Guide - Direct Mount  Chapter 8 Dresser ROOTS Commercial Rotary Meter Installation ......................... 81 Installation Prerequisites ......................................................................................................... 81           Installation Examples .............................................................................................................. 82 Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 83 B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive Programming Information .................................................................................................................. 85 B3, LMMA and S3A CTR/TC Meter Drive Rates:  Residential Direct Drive Programming* ... 87 Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser  ROOTS Rotary Meter ........................................................................................................................ 89 Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter ... 90 Programming the 100G Datalogging Commercial Gas Endpoint Assembly .......................... 91 B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter Drive Rates .............................. 93 To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter ............................. 95 Completed Installation Examples ............................................................................................ 97
 100G Datalogging Installation Guide - Direct Mount  1  Itron 100G Datalogging Gas Endpoints are radio-frequency (RF) devices designed to transmit meter data to an RF meter reading device within transmission distance of the endpoint. 100G Datalogging Gas Endpoints have the same increased output power as the first generation 100G Gas Endpoints for greater RF transmission distance. The 100G direct-mount endpoint reads and transmits a Standard Consumption Message (SCM) with magnetic-tamper and tilt-tamper data. The Itron 100G Datalogging direct-mount endpoint adds functionality by storing up to 40 days of hourly data.  This installation guide provides step-by-step instructions for installing the 100G Gas Endpoint and the 100G Datalogging Gas Endpoint on a wide variety of meters. This installation guide refers to both 100G endpoint versions as the 100G Datalogging Endpoint. Mechanical installation procedures are identical for both modules. 100G Datalogging Gas Endpoint compatible meters are listed in the Meter Compatibility List.    Transmission Modes The 100G Datalogging Gas Endpoint transmits in one of three modes:  • Fixed Network Mode   In this mode, a 100G Datalogging Gas Endpoint transmits a high-powered RF message every 60 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life is 20 years.  • Mobile and Handheld Mode   In this mode, a 100G Datalogging Gas Endpoint transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.  • (Optional) Hard to Read Mobile and Handheld Mode   In this mode, a 100G Datalogging Gas Endpoint transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).  An FCC license is not required to read 100G Datalogging Gas Endpoint.   CHAPTER  1  100G Datalogging Gas Endpoint
Chapter 1 100G Datalogging Gas Endpoint  2  100G Datalogging Installation Guide - Direct Mount  Specifications  Functional Specifications Description Power Source 100G 100G Datalogging  Two "A" cell lithium batteries One "A" cell lithium battery Tamper Detection Tilt tamper and magnetic tamper FCC Compliance Part 15 certified Industry Canada Compliance RSS-210 certified Intrinsically Safe per UL Class I, Division 1, Groups C and D Product Identification Numeric and barcoded endpoint type and serial number Construction Materials Gray polycarbonate housing and back plate with encapsulated electronics  Operational Specifications Description Operating Temperatures -40° to 158° F (-40° to +70° C) Operating Humidity 5 to 95 percent relative humidity Program Frequency 908 MHz Transmit Frequency Spread spectrum 908 to 924 MHz ISM band Data Integrity Verified in every data message     Related Documents Document Title Document Part Number Gas Endpoint Meter Compatibility List PUB-0117-002 Gas Endpoint Ordering Guide  PUB-0117-001 100G Datalogging Specification Sheet Publication 100941SP-01 Endpoint Link® Programming Guide TDC-0744 Meter Compatibility List The Meter Compatibility table lists meters compatible with the 100G Datalogging Gas Endpoint. Due to continuous research, product improvements, and enhancements, Itron reserves the right to change this list without notice.  Note  On rare occasions the location of endpoint-to-meter mounting holes on older diaphragm gas meters might not match up with the mounting holes on the 100G Datalogging Gas Endpoint. This can prevent the 100G Datalogging Gas Endpoint from properly mounting to the meter.
 Meter Compatibility List  100G Datalogging Installation Guide - Direct Mount  3  100G Series Meter Compatibility List Mfg. Model Description Class Comments Endpoint Type Endpoint Part No. Elster American/ Canadian  W75AL  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-175  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AT-175   Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  ALC-175  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AT-210  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-225 Canada only Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-250  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AR-250  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AC-250  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AM-250  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-310  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-350  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AT-350  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AL-425  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  AC-630  Residential Aluminum case meters only 100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  5B 225 Aluminum case  Residential  100G 100G Datalogging ERG-5000-001 ERG-5002-001 Elster American/ Canadian  35B Iron case Commercial   100G ERG-5000-007 Elster American/ Canadian  60B Iron case  Commercial   100G  ERG-5000-007 Elster American/ Canadian  80B Iron case Commercial  Must have front reading index. 100G  ERG-5000-007 Elster American/ Canadian  250B Iron case  Commercial  100G  ERG-5000-007 Elster American/ Canadian  500B Iron case Commercial   100G  ERG-5000-007 Elster American/ Canadian  AL800  Commercial Aluminum case meters only 100G  ERG-5000-007
Chapter 1 100G Datalogging Gas Endpoint  4  100G Datalogging Installation Guide - Direct Mount  Mfg. Model Description Class Comments Endpoint Type Endpoint Part No. Elster American/ Canadian  AL1000  Commercial Aluminum case meters only 100G  ERG-5000-007 Elster American/ Canadian  AL1400  Commercial Aluminum case meters only 100G  ERG-5000-007 Elster American/ Canadian  AL2300  Commercial Aluminum case meters only 100G  ERG-5000-007 Elster American/ Canadian  AL3000  Commercial  Aluminum case meters only 100G  ERG-5000-007 Elster American/ Canadian  AL5000  Commercial Aluminum case meters only 100G  ERG-5000-007 Sensus/Invensys/ Equimeter/Rockwell R-175 11-tooth  Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging  ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell R-200 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell RT-200 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell RC-225 11-tooth  (Canada only) Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell RT-230 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell R-275 11-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell RT-275 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell R-315 11-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell 250 11-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell 310 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell S-110 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell S-200 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell 175-S  18-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-004 ERG-5002-004 Sensus/Invensys/ Equimeter/Rockwell RT-100 18-tooth Residential 24- and 30-tooth gears are not compatible 100G 100G Datalogging ERG-5000-004 ERG-5002-004 Sensus/Invensys/ Equimeter/Rockwell S-190 18-tooth Residential 24- and 30-tooth gears are not compatible. 100G 100G Datalogging ERG-5000-004 ERG-5002-004
 Meter Compatibility List  100G Datalogging Installation Guide - Direct Mount  5  Mfg. Model Description Class Comments Endpoint Type Endpoint Part No. Sensus/Invensys/ Equimeter/Rockwell S-120 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell T-120 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell T-110 11-tooth Residential  100G 100G Datalogging ERG-5000-002 ERG-5002-002 Sensus/Invensys/ Equimeter/Rockwell R-415 18-tooth Residential Older meters may have endpoint-to-meter mounting hole variations that can make them incompatible. 100G 100G Datalogging ERG-5000-004 ERG-5002-004 Sensus/Invensys/ Equimeter/Rockwell RT-360 18-tooth  Residential  100G 100G Datalogging ERG-5000-004 ERG-5002-004 Sensus/Invensys/ Equimeter/Rockwell MR8  (R-275 Metric) 16-tooth Residential  100G 100G Datalogging ERG-5000-003 ERG-5002-003 Sensus/Invensys/ Equimeter/Rockwell MR12  (R-415 Metric) 16-tooth Residential  100G 100G Datalogging ERG-5000-003 ERG-5002-003 Sensus/Invensys/ Equimeter/Rockwell 750  Commercial  100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1000  Commercial  100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1600  Commercial  100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 3000  Commercial Vertical index only 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 5000  Commercial Vertical index only 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 10000  Commercial Vertical index only 100G ERG-5000-008 National/ Lancaster 175  Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 National/ Lancaster U175 UL175  Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 National/ Lancaster 250  Residential Actaris/Schlumberger/ Sprague direct-read (odometer) indexes cannot be used. 100G ERG-5000-006 Itron/Actaris/ Schlumberger/ Sprague 175  3-hole index box Residential Index boxes with 3 mounting holes 100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 175 WC  3-hole index box Residential Index boxes with 3 mounting holes 100G ERG-5000-005
Chapter 1 100G Datalogging Gas Endpoint  6  100G Datalogging Installation Guide - Direct Mount  Mfg. Model Description Class Comments Endpoint Type Endpoint Part No. Itron/Actaris/ Schlumberger/ Sprague 175  Combination 3-hole index box Integrated regulator Residential Index boxes with 3 mounting holes 100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 210  Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 240 Canadian Version of 250 Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 240  Combination Integrated regulator Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 240  Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 240 1-hole cover flat face Residential  Requires Itron 1A Adapter P/N  CFG-0015-001 Kit 100G ERG-5000-005  + CFG-0015-001 Itron/Actaris/ Schlumberger/ Sprague  240  2-hole cover Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 250  Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 250 WC  Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 250  Combination Integrated regulator Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 1A Flat face Includes 3-dial, 2cf indexes. Residential Requires Itron 1A adapter kit, CFG-0015-001 100G ERG-5000-005 + CFG-0015-001 Itron/Actaris/ Schlumberger/ Sprague METRIS 250 3-hole index box  Slant-faced Residential  Index boxes with 3 mounting holes  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 305  Combination Integrated regulator Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 400 Slant-faced Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 400A Slant-faced Residential  100G ERG-5000-005 Itron/Actaris/ Schlumberger/ Sprague 675A Top-mount index Commercial Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris 100G ERG-5000-007 Itron/Actaris/ Schlumberger/ Sprague 800A Top-mount index Commercial Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris   100G ERG-5000-007
 Meter Compatibility List  100G Datalogging Installation Guide - Direct Mount  7  Mfg. Model Description Class Comments Endpoint Type Endpoint Part No. Itron/Actaris/ Schlumberger/ Sprague 1000A Top-mount index Commercial Requires Itron/Actaris adapter p/n 80005901-001; purchase from Itron/Actaris 100G ERG-5000-007 EMCO #2 ½  Commercial  100G ERG-5000-008 EMCO #3  Commercial  100G ERG-5000-008 EMCO #4  Commercial  100G ERG-5000-008 EMCO #4 ½  Commercial  100G ERG-5000-008 EMCO #5  Commercial  100G ERG-5000-008 Dresser ROOTS Series B3 8C - 56M 8C - 16M  CTR TC (No pulser, No instrument drive) Commercial To attach an Elster American endpoint, install Dresser's Elster American AMR adapter kit.  100G 100G Datalogging Dresser adapter P/N 059599-000 ERG-5000-001 ERG-5002-001 Dresser ROOTS Series A1 (LMMA) 1.5M - 5M  CTR (No pulser, No instrument drive) Commercial To attach an Elster American  endpoint, install Dresser's Elster American AMR adapter kit.  100G 100G Datalogging Dresser adapter P/N 058530-610 ERG-5000-001 ERG-5002-001 Dresser ROOTS Series A1 (LMMA) 7M - 16M CTR (No pulser No instrument drive) Commercial To attach an Elster American endpoint, install Dresser's Elster American adapter kit. 100G 100G Datalogging Dresser adapter P/N 058531-610 ERG-5000-001 ERG-5002-001 Dresser ROOTS Series A1 (LMMA) 1.5M - 16M TC (No pulser No instrument drive) Commercial To attach an Elster American  endpoint, install Dresser's Elster American AMR adapter kit.  100G 100G Datalogging Dresser adapter P/N 058224-641 ERG-5000-001 ERG-5002-001 Dresser ROOTS 5C/8C15 Series Z compact meter Commercial To attach an Elster American endpoint, install Dresser's Elster American adapter kit. 100G 100G Datalogging Dresser adapter P/N 059847-000 ERG-5000-001 ERG-5002-001 Dresser ROOTS B3/LMMA Instrument drive CD/TD Commercial Standard index drive and no instrument. 100G ERG-5000-007
Chapter 1 100G Datalogging Gas Endpoint  8  100G Datalogging Installation Guide - Direct Mount  Installation Prerequisites Prior to installation, verify you have the following items: 1. 100G Datalogging Gas Endpoints designed for your specific brand of residential or commercial gas meters (endpoints include new tamper seals). 2. A compatible meter (see the Meter Compatibility List on page 2). 3. A compatible index. Itron 100G Datalogging Gas Endpoints are compatible with standard dial and direct-read (odometer) indexes. Exceptions are noted on the Meter Compatibility List on page 2. 4. Installation tools (provided by installer or customer) • Small and medium flat-blade or Phillips screwdrivers - to remove and tighten index and index-cover screws. • Side-cutting plier/wire snips - to cut wire seals, if applicable. • Small putty knife - residential meters. • Meter seals, wire seal, and seal press - to protect the meter from tampering, if applicable. • 11/32-inch nut driver or other blunt tool - to securely seat new tamper plugs over screw holes. • FC200SR handheld computer with Endpoint-Link® or EndPoint-Link Pro® software - to program and check 100G Datalogging Gas Endpoint installation and operation.  Caution  The 100G Datalogging Gas Endpoints can only be programmed using FC200SR Handheld Computers loaded with EndPoint-Link® or EndPoint-Link Pro® software version 5.3 or later.
 Installation Prerequisites  100G Datalogging Installation Guide - Direct Mount  9  • Replacement screws - to mount the 100G Datalogging Gas Endpoint assembly to the meter and the index to the endpoint housing:       Replacement Screws Meter To mount the 100G Datalogging Gas Endpoint on the meter: Itron Part Number To mount the index on the 100G Datalogging Gas Endpoint housing: Itron Part Number Elster American  1/4 - 20 x 5/8" slotted, Fillister head  8 - 32 x 3/16" slotted, round  pan-head  Sensus/Rockwell  10 - 24 x 5/8" slotted Fillister head  6 - 32 x 5/8" slotted, round  pan-head  Itron/Actaris  10 - 24 x 5/8" slotted Fillister head  10 - 24 x 1/4" slotted, round  pan-head  National/Lancaster  10 - 24 x 3/4" Phillips flat-head stainless steel  SCR-0014-004 6 - 19 x 3/8" thread-forming, Phillips pan-head to mount indexes with legs 6 - 19 x 3/8" thread-forming, Phillips, Fillister head to mount indexes with screw holes SCR-0015-001   SCR-0037-001 Commercial Meter To mount the 100G Datalogging Commercial endpoint on the meter: Itron Part Number To mount the index (and index assembly, if applicable) on the 100G Datalogging Commercial endpoint housing: Itron Part Number Elster American 2A x 3.25" length, slotted round-head drilled to accept utility-approved wire seals SCR-0062-001  (Elster American) 12 - 24 x 1/2" slotted, Fillister head machine screws, drilled to accept utility-approved wire seals  Sensus/Rockwell  2A x 3.63" length, slotted round-head drilled to accept utility-approved wire seals SCR-0062-002  2A x 2.94" length, slotted round-head SCR-0062-003
Chapter 1 100G Datalogging Gas Endpoint  10 100G Datalogging Installation Guide - Direct Mount
 100G Datalogging Installation Guide - Direct Mount 11  This chapter provides instructions to install the 100G Datalogging Gas Endpoint on an Elster American Meter.  Installing the 100G Datalogging Gas Endpoint involves four tasks: 1. Removing the index from the meter. 2. Assembling the 100G Datalogging Gas Endpoint and index. 3. Programming the 100G Datalogging Gas Endpoint assembly. 4. Attaching the 100G Datalogging Gas Endpoint assembly to the meter.   Note  Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises.  To remove the index from the meter 1. Remove the four index cover screws and the index cover from the Elster American meter. Alternate screw removal following the numbered pattern in the photo.   CHAPTER  2  Elster American Meter Installation
Chapter 2 Elster American Meter Installation  12 100G Datalogging Installation Guide - Direct Mount  2. Examine the mounting screws. If they are 5/8" long and not corroded, keep them to re-attach the 100G Datalogging Gas Endpoint assembly. If the screws are not the correct length or if the screws are corroded, discard.   Note You may use the removed index cover as a temporary storage container for screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises.  3. Unscrew one index mounting screw completely. Hold one hand under the index to catch the screw. While removing the other mounting screw, pull the index away from the meter to keep the index backplate against the back of the screw. Remove the screw completely after the index is free of the meter.   Set the index aside where it will not be damaged or fill with dirt, rain or snow. The index will be mounted to the endpoint later in this procedure. Verify the index mounting screws are 3/16" long and not corroded. If the screws are the correct length and not corroded, retain for later use. If the original screws were discarded, use the correct replacement screws (see Installation Prerequisites on page 8.) 4. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The meter face must be free of gasket residue before you install the 100G Datalogging Gas Endpoint.
 Installation Prerequisites  100G Datalogging Installation Guide - Direct Mount 13  To Assemble the 100G Datalogging Gas Endpoint and Index 1. Separate the 100G Datalogging Gas Endpoint housing from the cover by pulling the cover straight out from the housing.  2. Set the endpoint cover aside where it will not be damaged or fill with rain, dirt or snow. The cover will be used later in this installation procedure.
Chapter 2 Elster American Meter Installation  14 100G Datalogging Installation Guide - Direct Mount   Note  Elster American meter indexes are available in different models:  Index wrigglers on one-foot meters  with drive slots  Index meters on two-foot meters with drive posts  An Elster American index with  mounting screw holes  An Elster American index with mounting slots  If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting screw holes, perform steps 3 and 4, and skip steps 5 and 6. 3. Using the original index mounting screw or a replacement screw, if necessary, place one 8 - 32 3/16" screw into the index's right-hand mounting screw hole.
 Installation Prerequisites  100G Datalogging Installation Guide - Direct Mount 15  4. Attach the screw to the endpoint housing's right-index mounting post just enough to hold the screw and the right end of the index in place.   5. Screw one 8 - 32 x 3/16" screw into the right index mounting post one or two turns. Do not tighten the screw.  6. Place the right index mounting screw slot under the screw head. Do not tighten the screw.  7. Slide the index drive post into the endpoint wriggler. Verify positive engagement.   Caution  If the index wriggler has a drive slot, place the endpoint wriggler's drive post into the index drive slot. Failure to mate the endpoint wriggler with the index drive post (or slot) can cause binding and lead to poor registration or meter failure. 8. Install and tighten the left index mounting screw (for indexes with either mounting screw slots or holes). Tighten the right index mounting screw.
Chapter 2 Elster American Meter Installation  16 100G Datalogging Installation Guide - Direct Mount  9. Slide the endpoint cover over the index and housing. Verify the cover is installed correctly. The endpoint label should be clearly visible and easily read.   Programming the 100G Datalogging Gas Endpoint Assembly The 100G Datalogging Gas Endpoint must be programmed with the FC200SR handheld computer loaded with EndPoint-Link® or Point-Link Pro® software version 5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide (TDC-0744) for more complete programming information.    Caution  The 100G Datalogging Gas Endpoint must be programmed before use. Follow the steps in this section to properly program the endpoint.
 Programming the 100G Datalogging Gas Endpoint Assembly  100G Datalogging Installation Guide - Direct Mount 17  The endpoint is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower left dial on the index. The endpoint is programmed based on the drive rate. Elster American meter index drive rates are either 1-cubic foot or 2-cubic feet.        To Program the 100G Datalogging Gas Endpoint 1. Program the meter drive rate into the 100G Datalogging Gas Endpoint using the FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR as close to vertical as possible. For best success, keep the FC200SR within 6 feet of the target endpoint. Verify you have the correct programming mode (Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application. Programming parameters are based on the mode defined by your system administrator.  During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the endpoint assembly will read to the nearest cubic foot.  2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the index drive rate. This verifies the endpoint is counting properly after assembly.   Caution  Do not turn the drive wriggler faster than one turn per second.  3. Read the 100G Datalogging Gas Endpoint using the FC200SR.  • If the read result is higher than the number programmed in Step 1, the 100G Datalogging Gas Endpoint is counting correctly.  • If the read result is not higher than the number programmed in Step 1, replace the 100G Datalogging Gas Endpoint.
Chapter 2 Elster American Meter Installation  18 100G Datalogging Installation Guide - Direct Mount  Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint assembly to the Elster American Meter.  Warning  For 5B Meters only: If the 100G Datalogging Gas Endpoint will be installed on a 5B-225 aluminum meter, cut 1/16" off each endpoint wriggler post to prevent the wriggler from rubbing on the face of the nut holding the meter drive dog in place.     To Attach the 100G Datalogging Gas Endpoint 1. Align the endpoint wriggler to connect with the drive post (or slot) of the meter.        For one-foot meters: Align the endpoint assembly wriggler perpendicular to the meter drive post. For two-foot meters: Align the endpoint assembly wriggler perpendicular to the meter drive slot. The pin on the endpoint wriggler may be installed inside or outside the meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G Datalogging Gas Endpoint wriggler outside the meter drive slot.
 Attaching the 100G Datalogging Gas Endpoint Assembly to the Elster American Meter  100G Datalogging Installation Guide - Direct Mount 19  2. Carefully align the endpoint's four screw holes with the holes on the meter. Attach using the original mounting screws if they are the correct size and are not corroded (1/4 - 20 x 5/8" screws.) If the original screws were discarded, use the correct replacement screws (see Installation Prerequisites on page 8). Tighten in an alternating, diagonal pattern as shown in the photo:   • Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter connection. • Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter connection.  Return to the first screw and tighten. Continue with the second, third and last screw until all screws are tight. Use equal screw tension to tighten each screw.     Note Meter manufacturers should torque the mounting screws 15 to 20 inch-pounds. 3. Place new tamper seals over the two screws with tamper seal mounts. Press tamper seals into place using the 11/32" nut driver or similar blunt tool.
Chapter 2 Elster American Meter Installation  20 100G Datalogging Installation Guide - Direct Mount  4. Complete necessary paperwork and verify all excess materials are removed from the customer's premises. 100G Datalogging Gas Endpoint installation on the Elster American meter is complete.