Itron 100GDLCS AMR transceiver device for utility meters User Manual

Itron Inc AMR transceiver device for utility meters Users Manual

Users Manual

 Natural Gas Solutions 100G Series Gas ERT Module Installation Guide, Direct Mount  TDC-0823-014
 Identification 100G Series ERT Module Installation Guide, Direct Mount  6 July 2016   TDC-0823-014 100G, 100G DL, 100G DLN, 100G DLS, 100G DLT ERT module part numbers: 100G: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008 100G Datalogging: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008  100G Datalogging FN: ERG-5003-001, ERG-5003-002, ERG-5003-003, ERG-5003-004, ERG-5003-005, ERG-5003-006, ERG-5003-007, ERG-5003-008, ERG-5003-009 100G DLS: ERG-5006-001, ERG-5006-002, ERG-5006-003, ERG-5006-004, ERG-5006-005, ERG-5006-006, ERG-5006-007, ERG-5006-008, ERG-5006-009 100G DLT: ERG-5007-001, ERG-5007-002, ERG-5007-003, ERG-5007-004, ERG-5007-005, ERG-5007-006, ERG-5007-007, ERG-5007-008, ERG-5007-009 Copyright ©  2010 - 2016 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is used only for the purposes described herein. Any third party given access to this information is similarly bound in writing. Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700  Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118  Compliance Statement This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following two conditions:  • This device may not cause harmful interference.  • This device must accept any interference that may cause undesirable operation.  This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  • Reorient or relocate the receiving antenna.  • Increase the separation between the equipment and receiver.  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  • Consult the dealer or an experienced radio or TV technician for help.    Compliance Statement   This equipment complies with policies RSS-210 and RSS-GEN of the RSS-GEN of the Innovation, Science and Economic Development Canada (ISED) rules. Operation is subject to the following two conditions:  (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Déclaration de conformité Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, any 100G series gas ERT is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment.  Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.  Warning  Follow these procedures to avoid injury to yourself or others:  • The lithium battery may cause a fire or chemical burn if it is not disposed of properly. • Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to water, or incinerate the lithium battery.  • Keep the lithium battery away from children. • Fire, explosion, and severe burn hazard.  Warning  Only authorized and qualified personnel should attempt to install or service Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.  Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.  Warning  Substitution of components may impair intrinsic safety.  Warning  Electrostatic Ignition Hazard  Ensure area is not hazardous when installing, servicing, cleaning or touching the ERT module.  Warning  Clean only with a damp cloth. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount ii   Proprietary and Confidential
  Warning  ERT modules contain sensitive electronic components which can be damaged if the module is dropped from heights greater than 36 inches. Product warranty coverage is contingent on not exceeding this drop height limitation. Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: The information included in this guide is current as of the date of publication. Information within this guide including software versions and product names are subject to change without notice. Contact • Internet: www.itron.com • E-mail: support@itron.com • Phone: 1 877 487 6602   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount iii   Proprietary and Confidential
  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount iv   Proprietary and Confidential
 Before You Begin ........................................................................................................ vii Document Conventions ..................................................................................................................... vii Document Purpose ............................................................................................................................ vii About the 100G Gas ERT Module ................................................................................. 1 Transmission Modes ........................................................................................................................... 1 100G DLS ERT Module and Itron Security Manager .......................................................................... 2 Enabling 100G DLS ERT Module Security ............................................................................... 2 100G Series Gas ERT Module Specifications .................................................................................... 3 Related Documents ............................................................................................................................. 3 100G Gas ERT Module Meter Compatibility List ................................................................................ 4 Installation Prerequisites ................................................................................................................... 14 Installation Overview ............................................................................................................... 16 Elster American Meter Installation ............................................................................. 17 Removing the Meter Index ................................................................................................................ 17 Assembling the Gas ERT Module and Index .................................................................................... 18 Programming the 100G ERT Module Assembly ............................................................................... 20 Attaching the 100G ERT Module Assembly to the Meter ................................................................. 22 Sensus Meter Installation ........................................................................................... 24 Removing the Meter Index ................................................................................................................ 24 Assembling the Gas ERT Module and Index .................................................................................... 25 Programming the 100G Gas ERT Module Assembly ....................................................................... 27 Attaching the 100G Gas ERT Module Assembly to the Sensus Meter ............................................. 29 Itron Meter Installation ................................................................................................ 31 Removing the Meter Index ................................................................................................................ 31 Assembling the Gas ERT Module and Index .................................................................................... 32 Programming the Itron ERT Module Assembly ................................................................................. 34 Attaching the ERT Module Assembly to the Itron Meter ................................................................... 35 Attaching the ERT Module Assembly to Sprague Flat-faced Meters ................................................ 39 Securing Brass Meter Tags to Flat-faced Meters.............................................................................. 40 Attaching the ERT Module Assembly to a Sprague 175RM Meters ................................................. 42 Removing the Meter Index ...................................................................................................... 42 Assembling the Gas ERT Module and Index .......................................................................... 43 Programming the 100G ERT Module Assembly ..................................................................... 45 Installing the 100G Gas ERT Module Assembly on the Sprague 175RM Meter .................... 46 National (Lancaster) Meter Installation ...................................................................... 49 Removing the Meter Index ................................................................................................................ 49 Contents TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  v   Proprietary and Confidential
Contents  Assembling the Gas ERT Module and Index .................................................................................... 50 Programming the 100G Gas ERT Module Assembly ....................................................................... 53 Installing the 100G Gas ERT Module Assembly on the Meter .......................................................... 54 Elster American and Itron Commercial Meter Installation ....................................... 58 Removing the Index or Index Assembly from the Meter ................................................................... 58 Programming the 100G Datalogging FN Commercial Gas ERT ....................................................... 60 Attaching the Commercial 100G Gas ERT Module Assembly on the Commercial Meter ................ 62 Attaching the Commercial 100G Gas ERT Module to an Itron Commercial Meter ........................... 65 Programming the Commercial Gas ERT Module Assembly ............................................................. 69 Attaching the Commercial 100G Gas ERT Module Assembly on the Commercial Meter ................ 71 Sensus Commercial Meter Installation ...................................................................... 75 Removing the Index or Index Assembly from the Meter ................................................................... 75 Programming the Commercial Gas ERT Module Assembly ............................................................. 76 Installing the Commercial ERT Module Assembly to the Meter ........................................................ 78 Mounting a 100G DLS Gas ERT Module on a Rockwell 750 meter with an Aluminum BOX Direct Reading (VDR) .................................................................................................................................. 81 Installing the Commercial ERT Module Assembly to the Meter ........................................................ 82 GE Oil & Gas Dresser Commercial Rotary Meter Installation .................................. 85 Installation Prerequisites ................................................................................................................... 85 Installation Examples ........................................................................................................................ 86 Programming the 100G Gas ERT Module Assembly ....................................................................... 87 B3, LMMA, and S3A CTR/TC GE Dresser Series Register Settings and Direct Drive Programming Information......................................................................................................................................... 88 B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* .... 89 Installing the Residential ERT Module Assembly to the GE Dresser Rotary Meter .......................... 90 Installing the Commercial Gas ERT Module Assembly on a GE Dresser Rotary Meter with an Instrument Drive ................................................................................................................................ 91 Programming the Commercial Gas ERT Module .............................................................................. 91 B3, LMMA, and S3A CD/TD GE Dresser Meter Drive Rates ............................................................ 93 Completed Installation Examples ............................................................................................ 96 Romet Commercial Rotary Meter Installation ........................................................... 97 Installation Example .......................................................................................................................... 97 Programming the 100G Gas ERT Module Assembly ....................................................................... 97 Installing the Residential ERT Module Assembly to the Romet ........................................................ 99 Index ........................................................................................................................... 100    TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount vi  Proprietary and Confidential
 Document Conventions The following documentation conventions are used in this installation guide:  Caution   A Caution warns the installer that failure to follow the information in the note could result in loss of data. Be sure to carefully read a Caution note and follow the advice or instructions.  Warning  A Warning alerts the installer about potential physical harm to the installer or hardware. It is critical that you pay strict attention to Warning notes, read the information carefully, and follow the advice or instructions. Document Purpose This installation guide provides step-by-step instructions for installing the 100G series gas ERT module on a wide variety of meters. Mechanical installation procedures are identical for all 100G series gas ERT modules based on form or meter type. Compatible meters are listed in the  100G Gas ERT Module Meter Compatibility List.   Before You Begin  Tip  A Tip provides the installer with extra hints or suggestions to make a task easier to perform or a concept easier to understand.  Note  A Note supplies generic information to the installer. The installer can ignore the information and continue a task without suffering any adverse consequences. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount vii   Proprietary and Confidential
Before You Begin   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount viii  Proprietary and Confidential
 Itron 100G series gas ERT modules are radio-frequency (RF) devices designed to transmit meter data to an RF meter reading device within transmission distance of the ERT module. The 100G gas ERT was designed with a higher output power than earlier Itron gas ERT modules to achieve an increased RF transmission distance. The 100G series gas ERT modules have greater output power to meet Itron mobile and fixed network requirements. The first generation 100G gas ERT module offered high transmit power capability which increased operational efficiency and reduced infrastructure costs. The 100G Datalogging gas ERT module was enhanced to offer higher transmit power with data logging capability (time-stamped hourly interval data) for both mobile and fixed network applications. Itron's 100G Datalogging Fixed Network (DLN) gas ERT module added improved network performance through a higher transmit power, accomplished using increased antenna efficiency and more robust optimized messaging structures. Itron's 100G series gas ERT module brings increased efficiency in SCM+ messaging and adds enhanced network security. SCM+ messages expand the data fields within our standard consumption message to offer added value. The enhancement of secure communications provides greater protection for bubble-up and two-way messaging to prevent unauthorized users from gaining access to the system.   The 100G DLT Datalogging gas ERT module (100G DLT) is a hybrid in the Itron line of 100 Series radio frequency (RF) gas meter modules. The 100G DLT combines the circuit board hardware of the 100G DLS module with the SCM messaging used in the 100G DLN module. This allows utilities currently using the SCM messaging in the 100G DLN can upgrade to the 100G DLT without the upgrades required for programming, enhanced security, or meter reading. The 100G DLT does not offer the optional ISM enhanced security capability or extended tamper information available in the 100G DLS.   Transmission Modes The 100G series gas ERT module can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to Read Mobile and Handheld Mode.  • Fixed Network Mode.   The 100G transmits a high-powered network interval message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the high power NIM, the 100G DLS transmits a medium power RF message at 10 milliwatts or +10 dBm every 60 seconds; expected battery life is 20 years.  • Mobile High Power Mode.  The 100G transmits a high-powered RF message every 60 seconds. Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20 years. • Mobile and Handheld Mode.   The 100G transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.  • (Optional) Hard to Read Mobile and Handheld Mode.   The 100G transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).  CHAPTER  1  About the 100G Gas ERT Module TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  1   Proprietary and Confidential
About the 100G Gas ERT Module  • Itron Cellular Solutions (ICS) Mode.  The 100G DLS module is compatible with the Itron Cellular Solution and can be programmed for optimum operation with FDM Endpoint Tools Enhanced. In ICS mode, the 100G DLS transmits a high-powered network interval message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the high power NIM, the 100G transmits a medium power RF message at 10 milliwatts or +10 dBm every 60 seconds; expected battery life is 20 years. Note  ICS mode is for fixed network application only. ICS is optimized to work with the ICS communications module in Itron’s electric meter. The 100G DLS must be in a full security mode to work with ICS. This is not part of the ICS mode, but is a system level requirement.  An FCC license is not required to read 100G series gas ERT modules.   100G DLS ERT Module and Itron Security Manager The 100G DLS ERT module is a component of Itron's ChoiceConnect system. ChoiceConnect system enhanced security, provided by Itron Security Manager (ISM), applies to the RF communications between the handheld computer, Mobile Collector, or Fixed Network system and the ERT module. ISM is available in the 100G DLS module only.  There are two fundamental security processes used in the ChoiceConnect system to ensure system communication confidentiality and validity. • Authentication.  Authentication is the process of confirming that an artifact is genuine or valid. Authentication in the 100G DLS is the process of verifying a request is from a valid source and in its original form. • Encryption.  Encryption is the process of transforming information to make it unreadable to anyone who does not have a valid security key. There are two types of encryption, symmetric and asymmetric. Symmetric encryption uses a shared key to decrypt or encrypt information. Asymmetric encryption uses a private key to encrypt and a public key to decrypt. As a component of the Itron ChoiceConnect solution, the 100G DLS supports the security model found in the ChoiceConnect solution for both reading and programming. If the 100G DLS modules are shipped without ChoiceConnect enhanced security enabled (ready to secure), the utility can—at a later date—configure the ERT modules for ISM enhanced security.     Note  Enabling or working with Itron ISM enhanced security requires FDM Endpoint Tools Enhanced. Enabling 100G DLS ERT Module Security When 100G DLS ERT modules ship from an Itron factory, each module contains utility factory keys.  The presence of these utility factory keys does not enable the enhanced security; the installer enables the enhanced 100G DLS security at the time the ERT module is deployed or at a later time using an Itron programming device, Field Deployment Manager Endpoint Tools Enhanced, and programming commands. Initial key exchange commands are secured using the utility factory keys. For more information about programming the 100G DLS ERT module for security, see the FDM Endpoint Tools Mobile Application Guide (TDC-0934).      TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  2  Proprietary and Confidential
About the 100G Gas ERT Module  100G Series Gas ERT Module Specifications  Functional Specifications Description Power Source 100G  100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  Two "A" cell lithium batteries  One "A" cell lithium battery Tamper Detection Tilt and cut cable FCC Compliance Part 15 certified Industry Canada Compliance RSS-210 certified Intrinsically Safe per UL Class I, Division 1, Groups C and D Product Identification Numeric and bar coded ERT type and serial number Construction Materials Gray polycarbonate housing and back plate with encapsulated electronics  Operational Specifications Description Operating Temperatures -40° to 158° F (-40° to +70° C) Operating Humidity 5 to 95 percent relative humidity Program Frequency 908 MHz Transmit Frequency Frequency Hopping Spread spectrum 903 to 926.85 MHz in the ISM band Data Integrity Verified in every data message NIM Message FM modulation; all other messages are AM modulated   Related Documents  Document Title Document Part Number 100G Series Gas ERT Module Installation Guide, Direct Mount TDC-0823-XXX 100 Series Modules and CENTRON Bridge Meter Tamper Reference Guide TDC-1028-XXX 100 Series Gas and Telemetry Module Technology Guide TDC-0825-XXX Gas and Telemetry Module Meter Compatibility List PUB-0117-002 Gas and Telemetry Module Ordering Guide PUB-0117-001 100G DLS Gas ERT Module Specification Sheet Publication 101274SP-XX 100G DLN Gas ERT Module Specification Sheet Publication 100941SP-XX 100G DLT Gas ERT Module Specification Sheet Publication 101365SP-XX Field Deployment Manager Endpoint Tools Mobile Application Guide TDC-0934-XXX Field Deployment Manager Field Representative's Guide TDC-0936-XXX Note  The last three digits of the user and installation guides represent the document's revision level. The revision level is subject to change without notice.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  3   Proprietary and Confidential
About the 100G Gas ERT Module  100G Gas ERT Module Meter Compatibility List The following table lists meter types compatible with the 100G series gas ERT module. Due to continuous research and product improvements and enhancements, Itron reserves the right to change product or system specifications without notice.  Elster American (Canadian) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes W75AL Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AC-175 Aluminum case  100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL-175 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  ALC-175 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AT-175 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AT-210 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL-225 Aluminum case, Canada only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  5B-225 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001 Must cut 1/16" off the end of the module wriggler drive post which will make the module incompatible with other 2-ft. drive meters. AC-250 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  4  Proprietary and Confidential
About the 100G Gas ERT Module  Elster American (Canadian) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes AL-250 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AM-250 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AR-250 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AT-250 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL-310 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL-350 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL-425 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AC-630 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AC-800 Aluminum case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  AL800 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  AL1000 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  5   Proprietary and Confidential
About the 100G Gas ERT Module  Elster American (Canadian) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes AL1400 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  AL2300 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  AL3000 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  AL5000 Top mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  35B Iron case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  60B Iron case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  80B Iron case, must have front-reading index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  250B Iron case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  500B Iron case 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007  Rotary RPM Series (No pulser, no instrument) Use Elster American kit numbers 93179K002, 003, 004, or 005 to modify the meter with an adapter to attach a residential gas module. Purchase adapter from Elster American. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  6  Proprietary and Confidential
About the 100G Gas ERT Module  Elster American (Canadian) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes Rotary RPM Series  Instrument platform with mechanical drive. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007   GE Oil & Gas/Dresser Meters  Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes Series B3  8C—56M CTR 8C—16M TC (No pulser,  No instrument drive) To attach an Elster American residential ERT module, install GE Dresser’s Elster American AMR adapter kit, P/N 059599-000. Purchase AMR adapter from GE Dresser. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  Series A (LMMA) 1.5M—5M CTR (No pulser, No instrument drive) To attach an Elster American residential ERT module, install GE Dresser’s Elster American AMR adapter kit, P/N 058530-610. Purchase AMR adapter from GE Dresser. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  Series A (LMMA) 7M—16M CTR (No pulser, No instrument drive) To attach an Elster American residential 100G DLN, 100G DLS or 2.4GZ gas module, install GE Dresser’s Elster American AMR adapter kit, P/N 058531-610. Purchase AMR adapter from GE Dresser. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  Series A (LMMA) 1.5M—5M TC (No pulser, No instrument drive) To attach an Elster American residential ERT module, install Dresser's Elster American AMR adapter kit, P/N 058224-641. Purchase AMR adapter from Dresser. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  Series Z 5C/8C15 To attach an Elster American residential 100G DLN, 100G DLS or 2.4GZ gas module, install GE Dresser’s Elster American AMR adapter kit, P/N 059847-000. Purchase AMR adapter from GE Dresser. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  Instrument drive B3: CTR   TC, 8C—11M  LMMA: CTR   TC: 1.5M—11M Instrument platform with mechanical drive. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007 ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  7   Proprietary and Confidential
About the 100G Gas ERT Module  Itron (Actaris, Schlumberger, Sprague) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes 175  2-hole index cover  3-hole index cover 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  175 Combination  3-hole index cover  integrated regulator 2-hole index cover 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  175RM Flat-face meter Regulator on back of meter 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5003-009 ERG-5006-009 ERG-5007-009  175WC  3-hole index cover 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  210 Slant-face meter 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  240 Slant-face meter 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  240 Flat-face meter  1-hole index cover 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005 All modules require Itron 1A Adapter Kit,  Itron P/N CFG-0015-001. 240   2-hole index cover 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  240 Combination Integrated regulator 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  250 Slant-face  100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  I-250 Slant-face 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5003-005 ERG-5006-005  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  8  Proprietary and Confidential
About the 100G Gas ERT Module  Itron (Actaris, Schlumberger, Sprague) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes 250WC Integrated regulator 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  METRIS 250 Slant-face 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005 A longer mounting screw may be required when retrofitting to some vintage METRIS meters. Longer mounting screw is Itron P/N 010626. METRIS RM Slant-face meter, back inlet and outlet 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005 A longer mounting screw may be required when retrofitting to some vintage METRIS meters. Longer mounting screw is Itron P/N 010626. METRIS MB Slant-face meter, back inlet and outlet without regulator 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005 A longer mounting screw may be required when retrofitting to some vintage METRIS meters. Longer mounting screw is Itron P/N 010626. 1A Flat-face meter includes 3-dial, 2 cf indexes. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005 ERG-5007-005 Installation requires Itron 1A Adapter Kit, P/N CFG-0015-001. 305 Combination Integrated regulator 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  400 Slant-face meter 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  400A Slant-face meter 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005 ERG-5007-005  675A Top-mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007 Requires Itron (Actaris) adapter P/N 8005901-001. Purchase from Itron. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount  9   Proprietary and Confidential
About the 100G Gas ERT Module  Itron (Actaris, Schlumberger, Sprague) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes 800A Top-mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007 Requires Itron (Actaris) adapter P/N 8005901-001. Purchase from Itron. 1000A Top-mount index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007 Requires Itron (Actaris) adapter P/N 8005901-001. Purchase from Itron.  National (Lancaster) Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes 175  National meter indexes with bow-tie shaped wrigglers cannot be used. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-006 ERG-5002-006 ERG-5003-006 ERG-5006-006 ERG-5007-006 Actaris/Schlumberger/Sprague direct read (odometer) indexes cannot be used. U175 UL175 National meter indexes with bow-tie shaped wrigglers cannot be used. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-006 ERG-5002-006 ERG-5003-006 ERG-5006-006 ERG-5007-006 Actaris/Schlumberger/Sprague direct read (odometer) indexes cannot be used. 250 National meter indexes with bow-tie shaped wrigglers cannot be used. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-006 ERG-5002-006 ERG-5003-006 ERG-5006-006 ERG-5007-006 Actaris/Schlumberger/Sprague direct read (odometer) indexes cannot be used.  Romet  Meter Model Meter Notes 100G Module Type Itron Part Number Gas Module Notes RM series No pulser, no instrument drive Must purchase adapter kit from Romet 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging   ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001 ERG-5007-001  RM series. Instrument drive Instrument platform with mechanical drive 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5007-007   Sensus (Invensys/Equimeter/Rockwell/EMCO) Meter Model Meter Notes 100G Module Type Iron Part Number Gas Module Notes RT-100 18-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-004 ERG-5002-004 ERG-5003-004 ERG-5006-004 ERG-5007-004   S-110 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging  ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 10  Proprietary and Confidential
About the 100G Gas ERT Module  Sensus (Invensys/Equimeter/Rockwell/EMCO) Meter Model Meter Notes 100G Module Type Iron Part Number Gas Module Notes T-110 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging  100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   S-120 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   T-120 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   R-175 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   S-175 18-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-004 ERG-5002-004 ERG-5003-004 ERG-5006-004 ERG-5007-004   S-190 18-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-004 ERG-5002-004 ERG-5003-004 ERG-5006-004 ERG-5007-004   R-200 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   RT-200 11-tooth 100G  100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   S-200 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   RC-225 11-tooth (Canadian only) 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   RT-225 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 11   Proprietary and Confidential
About the 100G Gas ERT Module  Sensus (Invensys/Equimeter/Rockwell/EMCO) Meter Model Meter Notes 100G Module Type Iron Part Number Gas Module Notes RC-230 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   RCM-230 (RC-230 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003   RT-230 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   250 11-tooth 100G 100G Datalogging  100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002   Cubix250 11-tooth 100G 100G Datalogging  100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002  MR-7 (Cubix250 Metric) 11-tooth 100G 100G Datalogging  100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002  R-275 11-tooth 100G  100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002 24- and 30-tooth gears are not compatible. MR-8 (R-275 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003 24- and 30-tooth gears are not compatible. RT-275 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002  S-275 11-tooth (side connections) 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002  MR-5 (S-275 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003 24- and 30-tooth gears are not compatible. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 12  Proprietary and Confidential
About the 100G Gas ERT Module  Sensus (Invensys/Equimeter/Rockwell/EMCO) Meter Model Meter Notes 100G Module Type Iron Part Number Gas Module Notes MR-9 (R-315 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003 24- and 30-tooth gears are not compatible. 310 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002  R-315 11-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-002 ERG-5002-002 ERG-5003-002 ERG-5006-002 ERG-5007-002 24- and 30-tooth gears are not compatible. MR-9 (R-315 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003 24- and 30-tooth gears are not compatible. RT-360 18-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-004 ERG-5002-004 ERG-5003-004 ERG-5006-004 ERG-5007-004  415 18-tooth. Older meters may have gas module-to-meter mounting-hole variations that can make them incompatible. 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-004 ERG-5002-004 ERG-5003-004 ERG-5006-004 ERG-5007-004 24- and 30-tooth gears are not compatible. MR-12 (415 Metric) 16-tooth 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003 ERG-5007-003 24- and 30-tooth gears are not compatible. 750 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  1000 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  1600 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  3000 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 13   Proprietary and Confidential
About the 100G Gas ERT Module  Sensus (Invensys/Equimeter/Rockwell/EMCO) Meter Model Meter Notes 100G Module Type Iron Part Number Gas Module Notes 5000 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  10000 Vertical index only 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  750, 1000, 1600, 3000, 5000, 10000 Aluminum box direct reading (VDR) index 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008 Requires Itron mounting screws, P/N SCR-0062-001. Must purchase separately. EMCO #2-1/2 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  EMCO #3 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  EMCO #4 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  EMCO #4-1/2 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008  EMCO #5 100G 100G Datalogging 100G Datalogging FN 100G DLS Datalogging 100G DLT Datalogging ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008 ERG-5007-008    Installation Prerequisites Prior to installation, verify you have the following items: • 100G series gas ERT modules designed for your specific brand of residential or commercial gas meters (ERT modules include new tamper seals). • A compatible meter (see the  100G Gas ERT Module Meter Compatibility List). • A compatible index. Itron 100G series gas ERT modules are compatible with standard dial and direct-read (odometer) indexes. Exceptions are noted on the  100G Gas ERT Module Meter Compatibility List. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 14  Proprietary and Confidential
About the 100G Gas ERT Module  • Installation tools (provided by installer or customer). • Small and medium flat-blade or Phillips screwdrivers. • Side-cutting pliers/wire snips. • Small putty knife. • Meter seals, wire seal, and seal press. • 11/32-inch nut driver or other blunt tool.  • Itron programming device: FC200SR handheld computer with Field Deployment Manager (FDM) software  or FC300 with SRead with Field Deployment Manager (FDM) software or 900 MHz Belt Clip Radio with Field Deployment Manager (FDM) and a customer-supplied laptop   Note  The FDM version required is dependent upon the 100G ERT module model in use. • Replacement screws:     Replacement Screws Meter To mount the 100G series gas ERT module on the meter: Itron Part Number To mount the index on the 100G series gas ERT module housing: Itron Part Number Elster American  1/4 - 20 x 5/8" slotted, Fillister head  8 - 32 x 3/16" slotted, Fillister head   Sensus/Rockwell  10 - 24 x 5/8" slotted, Fillister head  6 - 32 x 5/8" slotted, Fillister head   Itron/Sprague   Sprague/Schlumberger 175 RM  10 - 24 x 5/8" slotted, Fillister head 10 - 24 x 1/2-inch, slotted Fillister head   SCR-0175-002 10 - 24 x 3/8" Fillister head 010040-002 National/Lancaster  10 - 24 x 3/4" Phillips, flat-head, stainless steel  SCR-0014-004 10 - 24 x 3/8" thread-forming, Phillips pan-head to mount indexes with legs 6 - 19 x 3/8" thread-forming, Phillips, Fillister head to mount indexes with screw holes SCR-0017-001   SCR-0037-001 Commercial Meter To mount the 100G  commercial ERT on the meter: Itron Part Number To mount the index (and index assembly, if applicable) on the 100G commercial ERT housing: Itron Part Number Elster American 2A x 3.35" length, slotted round-head drilled to accept utility-approved wire seals SCR-0062-001   12 - 24 x 1/2" slotted, Fillister head machine screws, drilled to accept utility-approved wire seals  Sensus 2A x 3.63" length, slotted round-head drilled to accept utility-approved wire seals SCR-0062-002  2A x 2.94" length, slotted round-head SCR-0062-003 Rockwell For Aluminum Box Direct Reading (VDR) index only SCR-0062-001     TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 15   Proprietary and Confidential
About the 100G Gas ERT Module  Installation Overview Installing the 100G series gas ERT module on a meter involves four tasks: 1. Removing the index cover and index from the meter. 2. Assembling the 100G and index. 3. Programming the 100G assembly. 4. Attaching the 100G to the meter.  Warning  ERT modules contain sensitive electronic components which can be damaged if the module is dropped from heights greater than 36 inches. Product warranty coverage is contingent on not exceeding this drop height limitation.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 16  Proprietary and Confidential
 This chapter provides the instructions to install the ERT module on an Elster American Meter.   Removing the Meter Index Begin the module installation by removing the index cover and index from the meter.  To remove the index from the meter 1. Remove the four index cover screws and the index cover from the Elster American meter. Alternate screw removal following the numbered pattern in the photo.   2. Examine the mounting screws. If they are 5/8-inch long and not corroded, keep them to install the 100G assembly to the meter. If the screws are not the correct length or if the screws are corroded, discard.  Note  You may use the removed index cover as a temporary storage container for screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials.  CHAPTER  2  Elster American Meter Installation TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 17   Proprietary and Confidential
Elster American Meter Installation  3. Unscrew one index mounting screw completely. Hold one hand under the index to catch the screw. While you remove the other mounting screw, pull the index away from the meter to keep the index backplate against the back of the screw. Remove the screw completely after the index is free of the meter.   Set the index aside where it will not be damaged or fill with dirt, rain or snow. You will mount the index to the ERT module later in this procedure.  4. Verify the index mounting screws are 3/16-inch long and not corroded. If the screws are the correct length and not corroded, retain for later use. If you discarded the original screws, use the correct replacement screws (see Installation Prerequisites on page 14). 5. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The meter face must be free of gasket residue and foreign materials before you install the 100G series gas ERT module.    Assembling the Gas ERT Module and Index Continue ERT module installation by assembling the ERT module and index.  To assemble the 100G series gas ERT module and index 1. Separate the ERT module housing from the cover by pulling the cover straight out from the housing.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 18  Proprietary and Confidential
Elster American Meter Installation  2. Set the ERT module clear cover aside where it will not be damaged or fill with rain, dirt, or snow. You will use the cover later in this installation procedure. Note  Elster American Meter indexes are available in different models: Index wrigglers on one-foot meters with drive slots         Index meters on two-foot meters with drive posts                                                          Index with mounting screw holes                                        Index with mounting slots                                                        If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting screw holes, perform steps 3 and 4, and skip steps 5 and 6. 3. Using the original index mounting screw or a replacement screw, if necessary, place one 8 - 32 3/16-inch screw into the index's right-hand mounting screw hole.    4. Attach the screw to the ERT module housing's right-index mounting post just enough to hold the screw and the right end of the index in place.   5. Screw one 8 - 32 x 3/16-inch screw into the right index mounting post loosely--one or two turns. Do not tighten the screw.  6. Place the right index mounting screw slot under the screw head. Do not tighten the screw.  7. Slide the index drive post into the ERT module shaft slot. Verify positive engagement.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 19   Proprietary and Confidential
Elster American Meter Installation  Caution  If the index wriggler has a drive slot, place the ERT shaft drive post into the index drive slot. Failure to mate the ERT module shaft with the index drive post (or slot) can cause binding and lead to poor registration or meter failure. 8. Install and tighten the left index mounting screw (for indexes with either mounting screw slots or holes). Tighten the right index mounting screw. Install and tighten index mounting screws evenly.   9. Slide the ERT module cover over the index and housing. Verify the cover is installed correctly. The ERT label should be clearly visible and easily read.   Programming the 100G ERT Module Assembly Program the 100G, 100G DL, 100G DLN, or 100G DLT ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 20  Proprietary and Confidential
Elster American Meter Installation  The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling command or enhanced security requires additional programming. Program the 100G DLS ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. To enable enhanced security and for more complete programming information, see the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934).       FC200SR               FC300 with SRead     900MHz Belt Clip Radio  Caution  You must program the 100G ERT module before use.  The ERT module is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower dial on the index. Elster American meter index drive rates are either 1-cubic foot, 2-cubic feet or 0.05 cubic meters (not shown below).         TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 21   Proprietary and Confidential
Elster American Meter Installation  To program the ERT module assembly 1. Program the meter drive rate into the 100G series gas ERT module using the endpoint programming device.  2. For all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as possible. For optimal results, keep the handheld programmer within 6 feet of the target ERT module.  3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.  4. Programming parameters are based on the configuration file loaded into the ERT module programming device. During programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot.   Attaching the 100G ERT Module Assembly to the Meter After you program the 100G, attach the ERT module assembly to the Elster American meter.  Warning  For 5B-225 aluminum meters only: cut 1/16-inch off each ERT wriggler post to prevent the wriggler from rubbing on the face of the nut holding the meter drive dog in place. Trimming the drive post may make the module incompatible with other 2-ft. drive meters.   To attach the ERT module to the meter 1. Align the ERT wriggler to connect with the drive post (or slot) of the meter.       • For one-foot meters: Align the ERT assembly wriggler perpendicular to the meter drive post. • For two-foot meters: Align the ERT assembly wriggler perpendicular to the meter drive slot. The pin on the ERT wriggler may be installed inside or outside the meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G wriggler outside the meter drive slot.  Warning  Failure to correctly align the meter drive post and ERT module drive slot can cause binding and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the meter, it may be the drive slot of the ERT module assembly's wriggler is not correctly aligned with the meter drive slot. Remove the 100G assembly and repeat the alignment procedure. You must engage the ERT module wriggler with the meter drive dog.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 22  Proprietary and Confidential
Elster American Meter Installation  2. Carefully align the ERT module's four screw holes with the holes on the meter. Attach the assembly using the original mounting screws if they are the correct size and are not corroded (1/4 - 20 x 5/8-inch screws.) If you discarded the original screws, use the correct replacement screws (see Installation Prerequisites on page 14). Tighten the screws in an alternating, diagonal pattern as shown in the photo:   • Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter connection. • Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter connection. • Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter connection.  3. Return to the first screw and tighten. Continue with the second, third and last screw until all screws are tight. Use equal screw tension to tighten each screw.   Important  Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds. 4. Place new tamper seals over the two screws with tamper seal mounts. Press tamper seals into place using an 11/32-inch nut driver or similar blunt tool.  5. Complete necessary paperwork and verify all excess materials are removed from the customer premises. 100G series gas ERT module installation on the Elster American meter is complete.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 23   Proprietary and Confidential
 This chapter provides the instructions to install the ERT module on a Sensus meter. These instructions apply to 11-tooth, 16-tooth, and 18-tooth Sensus 100G ERT modules.   Note Sensus meters are also known as Invensys, Equimeter, or Rockwell. For these instructions, all meter types are referred to as Sensus meters.      100G series gas ERT module  Sensus 11-tooth  Sensus 16-tooth  Sensus 18-tooth                     Removing the Meter Index Begin the module installation by removing the index cover and index from the meter.  To remove the index from the meter 1. Remove the four index cover screws and the index cover from the Sensus meter. Alternate screw removal following the numbered pattern as shown in the following photo.  2. Examine the mounting screws. If they are 5/8-inch long and not corroded, keep them to attach the 100G series gas ERT module assembly. If the screws are not the correct length or if the screws are corroded, discard them.  Note  You may use the removed index cover as a temporary storage container for screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on the customer premises.  CHAPTER  3  Sensus Meter Installation TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 24   Proprietary and Confidential
Sensus Meter Installation  3. Remove one index mounting screw completely. Hold one hand under the index to catch the screw. While removing the other mounting screw, pull the index away from the meter to keep the index backplate against the back of the screw. Remove the screw completely after the index is free of the meter.   4. Set the index aside where it will not be damaged or fill with dirt, rain, or snow. You will mount the index in the ERT later in this procedure.  5. Verify the index mounting screws are 5/8-inch long and not corroded. If the screws are the correct length and not corroded, retain for later use. If you discard the original screws, use the correct replacement screws (see Installation Prerequisites on page 14.) 6. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free of gasket residue or dirt before you install the 100G.     Assembling the Gas ERT Module and Index Continue ERT module installation by assembling the ERT module and index.  To assemble the ERT module and index 1. Separate the ERT module housing from the clear cover by pulling the cover straight out from the housing. Set the ERT module cover aside where it will not be damaged or fill with rain, dirt, or snow. You will replace the cover later in this installation procedure.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 25   Proprietary and Confidential
Sensus Meter Installation  2. Place the index drive gear (1) in the shaft gear cup (2) of the ERT. The example shows an 11-tooth drive gear. Your index may be a 16- or 18-tooth gear. Use the appropriate ERT module for your specific meter. See the  100G Gas ERT Module Meter Compatibility List for more information.  Warning  Indexes have varying drive mechanism styles. Failure to align the 100G DLS shaft with the index drive post can cause binding and lead to poor registration or meter failure. To verify proper engagement of the index to the 100G ERT module shaft, spin the wriggler one clockwise rotation, then one-counterclockwise rotation. Do not spin the shaft more than one complete rotation. The shaft should spin freely, with little or no resistance.  3. After the index drive gear is aligned and inserted into the shaft gear cup, the mounting holes will line up.  4. Using the original index mounting screw or a replacement screw (if necessary), place one 6 - 32 x 5/8-inch screw into the index right mounting screw hole.   5. Attach the screw to the ERT housing right-index mounting post just enough to hold the screw and the right end of the index in place.  6. Install and tighten the left index mounting screw.  7. Tighten the right index mounting screw completely. Install and tighten both index mounting screws evenly.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 26  Proprietary and Confidential
Sensus Meter Installation  8. Slide the ERT cover over the index and housing. Verify the cover is installed correctly. The ERT label should be clearly visible and easily read.   Programming the 100G Gas ERT Module Assembly Program the 100G, 100G DL, 100G DLN, or 100G DLT ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling command or enhanced security requires additional programming. Program the 100G DLS ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or •  A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth.See the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) for more complete programming information. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 27   Proprietary and Confidential
Sensus Meter Installation  To enable enhanced security and for more complete programming information, see the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934).       FC200SR               FC300 with SRead     900MHz Belt Clip Radio  Caution  You must program the 100G ERT module before use.  The ERT is programmed based on the meter's drive rate. Take note of the index drive rate shown on a lower dial on the index. Sensus meter index drive rates are typically 2-cubic feet.       To program the ERT module assembly 1. Program the meter drive rate into the 100G series gas ERT module using the endpoint programming device.  2. For all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as possible. For optimal results, keep the handheld programmer within 6 feet of the target ERT module.  3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.  4. Programming parameters are based on the configuration file loaded into the ERT module programming device. During programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot.    TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 28  Proprietary and Confidential
Sensus Meter Installation  Attaching the 100G Gas ERT Module Assembly to the Sensus Meter After 100G series gas ERT module programming is complete, attach the ERT module assembly to the Sensus meter.  To attach the ERT module assembly to the meter 1. Place the ERT assembly against the front of the meter at angle.  Warning  Failure to correctly align the meter drive gears and ERT module drive gears can cause binding and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the meter, it may be the drive gears of the ERT module assembly's wriggler are not correctly aligned with the meter drive gears. Remove the 100G assembly and repeat the alignment procedure. You must engage ERT module wriggler with the meter drive gears.   2. Install and tighten the ERT-to-meter mounting screws in an alternating pattern. Use the original mounting screws if they were the correct size and not corroded. If you discarded the original screws, use the correct replacement screws (see Installation Prerequisites on page 14). Caution  As the ERT module assembly is secured into its final position on the meter, shifting may occur due to existing tolerances within the mounting screw holes. To ensure full ERT wriggler gear to meter gear engagement, push the ERT module to the right while tightening the screws in the following pattern. • Align the top right mounting screw hole on the meter with the top right screw hole on the ERT module.  • Insert the top right cover mounting screw and tighten the screw enough to hold the ERT module assembly in place. Do not completely tighten the screw.  • Rotate the ERT module assembly counterclockwise until the remaining three ERT screw holes line up with the holes in the meter.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 29   Proprietary and Confidential
Sensus Meter Installation  3. Install the remaining three mounting screws and tighten in the pattern shown in the following illustration.   2. Insert lower left mounting screw (2) and tighten to snug position. 3. Tighten upper right mounting screw (1,3) to snug position. 4. Insert upper left mounting screw (4) and tighten to snug position. 5. Insert lower right mounting screw (5) and tighten to snug position. Tighten each mounting screw evenly. Important  Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds.  4. Place a new tamper seal over the two screws with tamper seal cups. Press the new tamper seals into place using an 11/32-inch nut driver (or similar blunt tool).    5. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the customer premises. 100G series gas ERT module installation on the Sensus meter is complete.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 30  Proprietary and Confidential
 This chapter provides the instructions to install the ERT module on an Itron meter.   Note  Itron meters are also known as Actaris, Schlumberger, or Sprague meters. For these instructions, all meters will be referred to as Itron meters.    Removing the Meter Index Begin the module installation by removing the index cover and index from the meter.  To remove the index from the meter 1. Remove the index cover screws and the index cover from the Itron meter. Examine the mounting screws. If they are 5/8-inch long and not corroded, keep them to re-attach the 100G assembly. If the screws are not the correct length or if the screws are corroded, discard them.   Note  Use the removed index cover as a temporary storage container for the screws. Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials.  CHAPTER  4  Itron Meter Installation TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 31   Proprietary and Confidential
Itron Meter Installation  2. Loosen the index mounting screws 1/2 to one turn. Slide the index to the left and off the mounting screws. Remove the index from the meter.     3. Set the index aside where it will not be damaged or fill with dirt, rain, or snow. You will mount the index to the ERT module later in this procedure.  4. Verify the index mounting screws are 1/4-inch long and not corroded. If the screws are the correct length and not corroded, retain for later use. If you discard the original screws, use the correct replacement screws (see Installation Prerequisites on page 14). 5. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free of gasket residue or dirt before you install the 100G.    Assembling the Gas ERT Module and Index Continue ERT module installation by assembling the ERT module and index.  To assemble the ERT module and index 1. Separate the 100G housing from the cover by pulling the cover straight out from the housing. Set the ERT cover aside where it will not be damaged or fill with rain, dirt or snow. You will use the cover later in this installation procedure.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 32  Proprietary and Confidential
Itron Meter Installation  2. Insert the 10 - 24 x 1/4-inch screws into the index mounting posts two turns. Do not tighten the screws.    3. Align the index wriggler (1) with the drive post of the ERT shaft (2). Carefully slide the index onto the mounting screws.         4. Verify the 100G shaft drive post makes positive engagement with the index wriggler.  Warning  Indexes have varying drive mechanism styles. Failure to align the ERT shaft with the index drive post can cause binding and lead to poor registration or meter failure. To verify proper engagement of the index to the ERT shaft, spin the wriggler one clockwise rotation, then one-counterclockwise rotation. Do not spin the wriggler more than one complete rotation. The wriggler should spin freely, with little or no resistance.  5. Hold the index in place and tighten the index mounting screws.   Warning  Verify the index is correctly positioned all the way to the right on the index mounting screws before you tighten the index mounting screws. Failure to properly mount the index on the index mounting screws may cause binding and meter failure. 6. Slide the ERT module cover over the index and housing. Verify the cover is installed correctly. The ERT module label should be clearly visible and easily read.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 33   Proprietary and Confidential
Itron Meter Installation  Programming the Itron ERT Module Assembly Program the 100G, 100G DL, 100G DLN, or 100G DLT ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling command or enhanced security requires additional programming. Program the 100G DLS ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. To enable enhanced security and for more complete programming information, see the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934).     FC200SR               FC300 with SRead        900MHz Belt Clip Radio  Caution  You must program the ERT module before use.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 34  Proprietary and Confidential
Itron Meter Installation  The ERT module is programmed based on the meter's drive rate. Take note of the index drive rate shown on the drive dial on the index. The ERT is programmed based on the drive rate. Itron meter index drive rates are typically 2-cubic feet.     To program the ERT module assembly 1. Program the meter drive rate into the 100G series gas ERT module using the endpoint programming device.  2. For all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as possible. For optimal results, keep the handheld programmer within 6 feet of the target ERT module.  3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.  4. Programming parameters are based on the configuration file loaded into the ERT module programming device. During programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot.   Attaching the ERT Module Assembly to the Itron Meter After you program the ERT module, attach it to the Itron meter.   To attach the ERT module to the meter 1. Align the ERT so one of its four drive fins (1) lines up with the meter drive dog (2).          TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 35   Proprietary and Confidential
Itron Meter Installation   Warning  Failure to correctly align the meter drive post and ERT module wriggler can cause binding and lead to poor registration or meter failure. If there is a gap between the ERT module gasket and the meter, it may be the wriggler of the ERT module is dead-headed against the meter drive dog as shown in the following illustration.   Remove the 100G ERT module assembly and repeat the alignment procedure. You must engage the meter drive post with the ERT module wriggler.  2. Place the 100G on the meter.  3. Insert the right module mounting screw and tighten the screw until the gasket is against the meter. Do not completely tighten the mounting screw.  Note  Use the original mounting screws to mount the 100G if they were the correct size and not corroded. If you discarded the original screws, use the correct replacement screws (see Installation Prerequisites on page 14.)   4. Slightly raise the left side of the ERT module (the module will rotate on the right screw) until the left ERT module mounting hole is approximately 1/4-inch above the left meter mounting hole.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 36  Proprietary and Confidential
Itron Meter Installation  5. Rotate the ERT module down until the module mounting hole is approximately 1/4-inch below the meter hole.  6. Rotate the ERT module up to align the left mounting holes. Raising and lowering the ERT module on the meter drive post facilitates the proper positioning and engagement of ERT module wriggler with the meter drive post.   7. Insert the left mounting screw and tighten a few turns.  8. Tighten the right and left ERT-to-meter mounting screws in an alternating pattern. Tighten each mounting screw evenly.  Important  Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds. TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 37   Proprietary and Confidential
Itron Meter Installation  Tip  The following conditions ensure proper engagement of the ERT module to the meter: •  The ERT module fits flush against the meter body--there are no gaps between the ERT gasket and the meter body. • The ERT module mounting holes align with the index cover mounting holes on the meter body. • The meter test dial moves in relation to gas flowing through the meter. 9. Place a new tamper seal in the tamper seal cups surrounding the two mounting screws.  Press the new tamper seals into place using an 11/32-inch nut driver or similar blunt tool.   10. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the customer premises. 100G ERT module installation on the Itron meter is complete.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 38  Proprietary and Confidential
Itron Meter Installation  Attaching the ERT Module Assembly to Sprague Flat-faced Meters 100G ERT module installation on a flat-faced Sprague meter requires the Itron Adapter Plate Kit (CFG-0015-001).   Itron Adapter Plate Kit (CFG-0015-001) 1  Adapter Shim Plate 2  Index Cover Mounting Screws 3  Drive Dog 4  Adapter Plate Mounting Screws    To attach the ERT module assembly to the flat-faced Sprague meter 1. Verify the kit includes the materials listed in the Itron Adapter Plate Kit table.  Warning  The adapter plate must fit flush against the meter face. Some older Sprague meters are not compatible with the adapter plate. The following examples illustrate the potential obstruction (problem) areas between the adapter plate and meter. Failure to mount the adapter plate flush on the front of a meter could result in a binding condition and lead to poor registration or meter failure.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 39   Proprietary and Confidential
Itron Meter Installation  2. Remove the drive dog from the flat-faced Sprague meter. Replace it with the extended drive dog included in the kit. Hand-tighten to snug. Warning  A gasket surrounds the meter drive dog shaft. A gas leak could result if the gasket is damaged. Do not use a tool to install or tighten the new drive dog. Hand-tighten only. • Attach the adapter plate to the meter with the gasket against the meter face. Secure the plate to the meter with the two adapter plate mounting screws. Tighten the screws in an alternating pattern. • Insert the right adapter plate screw and tighten the screw enough to hold it in place.  • Install the left mounting screw and tighten to a snug fit.  • Finish by tightening the right mounting screw to a snug fit.  Tighten each screw evenly. Note  The 100G must be assembled and programmed following the instructions in To assemble the ERT module and index on page 32 and Programming the ERT Module Assembly on page 20 prior to installation on the meter.  Securing Brass Meter Tags to Flat-faced Meters Some older Sprague meters have metal index covers with brass meter tags attached (by screws or rivets) to metal index covers.   Typically, brass meter tags have mounting (screw/rivet) holes on each end of the tag.  Mount brass meter tags using one of three Itron-approved methods.  To secure brass meter tags to flat-faced meters Method 1 and 2  1. Carefully remove the brass meter tag from the meter index cover. Try not to damage the meter tag mounting holes.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 40  Proprietary and Confidential
Itron Meter Installation  2. Attach the 100G assembly to the meter. The Sprague adapter plate has tag mounting holes in the lower left and right corners. Secure the meter tag to one of the holes with a utility-approved and provided security seal.    Method 1: Attach the meter tag to the adapter plate tag mounting hole  Method 2: Attach the meter tag to the 100G mounting hole Note  If the brass meter tag will be secured to the meter utilizing the ERT-to-meter mounting hole, it must be attached during the 100G series gas ERT module installation procedure described in Step 1 of Attaching the ERT Module Assembly on the Meter on page 35. Caution  A protruding brass meter tag can present a safety concern particularly if the tag is damaged with sharp edges protruding from the meter. Method 3 1. Remove the 100G index cover. 2. Place the meter tag inside the ERT assembly for optimal meter tag security. (See To assemble the ERT module and index on page 32.)  Method 3: Place the brass meter tag inside the ERT module assembly  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 41   Proprietary and Confidential
Itron Meter Installation  Attaching the ERT Module Assembly to a Sprague 175RM Meters This section provides the information to attach the 100G to a Sprague 175RM meter.   Removing the Meter Index Begin the module installation by removing the index cover and index from the meter.  To remove the index from the meter 1. Remove the index cover mounting screws and the index cover from the Sprague 175RM meter. Discard the index cover and index cover mounting screws.    Note  The removed index cover may be used as a temporary refuse container for screws. Properly dispose the index cover and all unused screws, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises.  2. Loosen the index mounting screws 1/2 to one turn. Slide the index up and off the mounting screws and remove it from the meter.  Set the index aside where it will not be damaged or fill with dirt, rain or snow. You will mount the index in the module later in this procedure. Remove the index mounting screws from the meter. Verify the index mounting screws are 1/4-inch long and not corroded. If the screws are the correct length and not corroded, retain for later use. If the original screws are discarded, use the correct replacement screws (see Installation Prerequisites on page 14). TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 42  Proprietary and Confidential
Itron Meter Installation  3. Remove the old gasket, gasket residue, and dirt from the meter (if applicable). The meter face must be free of gasket residue or dirt before you install the 100G.   Note  Properly dispose all unused screws, old index covers, gaskets, tamper seals, and other leftover materials. Do not leave materials on customer premises.  Assembling the Gas ERT Module and Index Continue ERT module installation by assembling the ERT module and index.  To assemble the 100G series gas ERT module and index 1. Separate the ERT module housing from the cover by pulling the cover straight out from the housing. Set the module cover aside where it will not be damaged or fill with rain, dirt or snow. The cover is used later in this installation procedure.  2. Screw the index mounting screws into the index mounting posts loosely (one to two turns). Do not tighten the screws.    TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 43   Proprietary and Confidential
Itron Meter Installation  3. Align the index wriggler (1) with the ERT module drive post (shaft, 2).      4. Carefully slide the index onto the mounting screws. Verify the 100G housing drive post makes positive engagement with the index wriggler.  Caution  Indexes have varying drive mechanism styles. Failure to align the ERT shaft with the index drive post can cause binding and lead to poor registration or meter failure. To verify proper engagement of the index to the ERT shaft, spin the wriggler one clockwise rotation, then one-counterclockwise rotation. Do not spin the wriggler more than one complete rotation. The wriggler should spin freely, with little or no resistance.  5. Hold the index in place and tighten the index mounting screws.  6. Slide the ERT module cover over the index and housing. Verify the cover is installed correctly. The label should be clearly visible and easily read.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 44  Proprietary and Confidential
Itron Meter Installation  Programming the 100G ERT Module Assembly Program the 100G, 100G DL, 100G DLN, or 100G DLT ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 1.1 or higher or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 1.1 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. The 100G DLS ERT modules support enhanced security with the Itron Security Manager. Enabling command or enhanced security requires additional programming. Program the 100G DLS ERT modules using: • An FC200SR handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • An FC300 with SRead handheld computer with Field Deployment Manager (FDM) software version 3.3 or higher   or • A 900MHz Belt Clip Radio with Field Deployment Manager (FDM) software version 3.3 or higher and a customer-supplied laptop. The Belt Clip Radio connects to the user-supplied laptop using a USB cable or Bluetooth. To enable enhanced security and for more complete programming information, see the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934).     FC200SR               FC300 with SRead        900MHz Belt Clip Radio  Caution  You must program the 100G ERT module before use.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 45   Proprietary and Confidential
Itron Meter Installation  The ERT module is programmed based on the meter's drive rate. Take note of the index drive rate shown on the drive dial on the index. The ERT module is programmed based on the drive rate. Sprague meter index drive rates are typically 2-cubic feet.     To program the ERT module assembly 1. Program the meter drive rate into the 100G series gas ERT module using the endpoint programming device.  2. For all programming and Check Endpoint operations, hold the handheld programmer as close to vertical as possible. For optimal results, keep the handheld programmer within 6 feet of the target ERT module.  3. Verify you have the correct programming mode (Fixed Network Mode, Mobile High Power Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your application.  4. Programming parameters are based on the configuration file loaded into the ERT module programming device. During programming, the 100G is set to the nearest 100 cubic feet; the last two digits (tens and units) are programmed as zeros (0). After programming is complete, the ERT module assembly will read to the nearest cubic foot.    Installing the 100G Gas ERT Module Assembly on the Sprague 175RM Meter After you program the 100G, install the ERT assembly on the Sprague 175RM meter.  To install the ERT module on the 175RM meter 1. Align the module wriggler (1) with the meter's drive dog (2).  Warning  Failure to properly align the ERT wriggler with the meter drive post can cause binding and lead to poor registration or meter failure.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 46  Proprietary and Confidential
Itron Meter Installation  2. Use the replacement mounting screws shipped with the 100G. Install module-to-meter mounting screws in an alternating pattern. • Insert the right module mounting screw and tighten the screw enough to hold it in place. Do not completely tighten the screw.  • Install the lower left module mounting screw and tighten two turns.  • Insert the lower right mounting screw and tighten two turns.  • Insert the upper left mounting screw and tighten to snug.  • Tighten the mounting screws in an alternating diagonal fashion as shown in the photo below.  Tighten each mounting screw evenly. Important  Meter manufacturers: torque the mounting screws 15 to 20 inch-pounds.  TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 47   Proprietary and Confidential
Itron Meter Installation  3. Place a new tamper seal over the two screws in the tamper seal cups. Press the new tamper seals into place using an 11/32-inch nut driver or similar blunt tool.   4. Complete any necessary paperwork and properly dispose excess installation materials and scrap from the customer premises. 100G installation on the Sprague 175RM meter is complete.   TDC-0823-014 100G Series Gas ERT Module Installation Guide, Direct Mount 48  Proprietary and Confidential

Navigation menu