Ingenico CPEM-E1K6567 CONTACTLESS PAYMENT EXPANSION MODULE User Manual USERS MANUAL

Ingenico CONTACTLESS PAYMENT EXPANSION MODULE USERS MANUAL

USERS MANUAL

Contactless Payment Expansion Module for the eN-Touch 1000 Installation Guide
  Contactless Payment  Expansion Module eN –Touch 1000 Installation Guide Contactless Payment  Expansion Module for the eN –Touch 1000 Installation Guide  Part Number DIV350403, Revision  A Released July 2005 Copyright 2005, Ingenico Corp. All rights reserved. No part of this publication may be copied, distributed, stored in a retrieval system, translated into any human or computer language, transmitted, in any form or by any means, without the prior written consent of Ingenico. Ingenico and Ingenico logo are registered trademarks of Ingenico Corp. All other brand names and trademarks appearing in this guide are the property of their respective holders. Information in this document is subject to change without notice. Noncontractual document. INGENICO owns exclusive rights to this document. All distributions, copies, entire or partial production, by any process, made without the authorization of INGENICO will be considered illicit, and will form an infringement, penalized by the L.335-2 clause and following clauses of the Code of Intellectual Property. INGENICO reserves the right to modify the characteristics and the functions of this device without notice. INGENICO is not responsible for any use of this device which would be inconsistent with this document.  Ingenico Inc. 1003 Mansell Road Atlanta, GA   30076 Tel:  770.594.6000 Fax: 770.594.6003 www.ingenico-us.com  U.S. Help Desk: TotalCARE Tel:  800.435.3014 Fax: 770.594.6026  Ingenico Canada Ltd. 79 Torbarrie Road, Toronto, Ontario Canada M3L 1G5 Tel:  416.245.6700 Fax: 416.245.6701 www.ingenico-ca.com  Canadian Help Desk: TotalCARE. Tel:  888.900.8221  Fax: 905.795.9343
  Contactless Payment  Expansion Module eN –Touch 1000  Installation Guide  1 Table of Contents 1 Overview ..............................................1 2 Installation Components .......................1 3 Installation Procedure ..........................2 3.1 Preparing the Terminal for the Installation................................ 2 3.2 Expansion Module Installation Steps......................................... 3 4 Testing the Installation.........................6 5 Product Certification............................7  1 Overview This document describes how to install the Contactless Payment Expansion Module on the eN-Touch 1000 terminal. The Expansion Module is based on RFID technology and enables the terminal to read contact-less smartcards. The eN -Touch 1000 is available in 2 models, Tyco/Loki and Thor that have different plastic feet.  See Figure 1.   Figure 1: Terminal Foot area for Thor and Tyco/Loki models This installation guide applies to both models. 2 Installation Components The Expansion Module package contains all the components required for upgrading either of the two eN -Touch 1000 models.  The kit Tyco/Loki Thor
 2  Contactless Payment  Expansion Module eN –Touch 1000 Installation Guide includes the following: Card Reader Unit, Cable, Tyco/Loki Foot, Thor Foot, Wedge, Double sided tape and Plastic bag with one mounting screw and two self-adhesive rubber bumps Only the Expansion Module Foot for your terminal model is required! 3 Installation Procedure ! - Only upgrade terminals that are in working order. - This procedure requires a Philips screw driver.  3.1  Preparing the Terminal for the Installation 1. Disconnect the terminal from power. 2. Place the terminal on a flat surface with the bottom side facing up. 3. Remove the existing Foot from the terminal. Note different procedure for the two models: • Thor model only:  Using a screwdriver remove the two mounting screws and detach the Foot. Retain the screws for the Expansion Module installation. • Tyco/Loki model only:  Pinch the middle of the Foot to release the locking clip and then remove the Foot. See Figure 2.  Figure 2: Removing the existing Tyco/Loki Foot 4. Disconnect any installed cables from the terminal.
  Contactless Payment  Expansion Module eN –Touch 1000  Installation Guide  3 3.2 Expansion Module Installation Steps Step 1: Assemble the cable assembly into the Foot required for your installation as shown in Figure 3.  Ensure that the cable is positioned in the cable retention feature of the Foot. Note that the cable is routed differently according to the model you have: for the Tyco/Loki model place the Minidin 9 cable under the RJ cable.    Figure 3: Cable/Foot assembly  Step 2: Insert the RJ connector from the assembled Cable/Foot into the Reader Unit jack, as shown in Figure 4.    Figure 4: Connect RJ cable to the Reader Unit Step 3: Attach the Reader Unit to the Foot by using the two foot mounting tabs and the mounting screw. See Figure 5 Tyco/Loki Thor  Reader Unit RJ Minidin 9 RJ Minidin 9Screw hole Antenna
 4  Contactless Payment  Expansion Module eN –Touch 1000 Installation Guide  Figure 5: Foot/Reader Unit assembly  Step 4A-Tyco/Loki model only: Attach the Foot/Reader Unit assembly to the terminal by connecting first the Minidin 9 connector to the terminal jack, than placing the two bottom mounting tabs of the Foot into the terminal recesses and finally by squeezing in the top mounting tab of the Foot into matching locating hole of the terminal.   Foot mounting screws are NOT required.  See Figure 6.   Figure 6: Attach Tyco/Loki Expansion Module to the terminal Step 4B-Thor model only: Same procedure as for Tyco/Loki model except the different position of the Foot mounting tabs, Foot mounting screws and of the Minidin 9 terminal jack. Foot mounting screws need to be applied.  Use the screws removed from the terminal Foot. See Figure 7.   Mounting screw
  Contactless Payment  Expansion Module eN –Touch 1000  Installation Guide  5  Figure 7: Attach the Thor Expansion Module to the terminal Step 5: Apply the two self-adhesive rubber bumps to the Module Foot as shown in Figure 7.  The orientation angle of the Card Reader antenna can be adjusted through 3 discrete positions.  The optional Antenna Positioning Wedge included in the kit can be used to fix the antenna semi-permanently in Position 1 or Position 2. Position 3 does not require the wedge. If the installation of the Antenna Positioning Wedge is required follow Step 6 and Step 7.  Step 6: Place the double sided tape for the required wedge position as indicated in Figure 8.  Figure 12: Application of double sided tape Self-adhesive bumps here  Screws hereWedge position 1 Wedge position 2 Double sided tape hereDouble sided tape here
 6  Contactless Payment  Expansion Module eN –Touch 1000 Installation Guide   Step 7: Install the Wedge as follows: • Fully insert the Wedge for the desired position in the recess at the back of the Antenna as shown in Figure 9. • Ensure the Wedge is located and attached properly to the top of the Reader surface through the use of the included double sided tape. • Check the Wedge is locked in the Antenna recess by pushing the Antenna against the Wedge as shown by the arrows.   If movement, reposition. Figure 9. Figure 10 shows the results of the Wedge installation.   Figure 9: Wedge installation   Figure 10: Wedge installed 4  Testing the Installation  ! 1- Ensure that an application to test contact-less smartcards is loaded in the terminal. 2- A compatible contact-less smartcard is required.   wedge position 1  wedge position 2  antenna  antenna
  Contactless Payment  Expansion Module eN –Touch 1000  Installation Guide  7  Figure 17: Reading a contact-less smartcard • Place the contact-less smartcard near the Card Reader.  • Confirm the successful reading of the contact-less smartcard.  5 Product Certification ! This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:  (1)  this device may not cause harmful  interference  (2)  this device must accept any interference received, including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  • Reorient the receiving antenna  • Increase the separation between the equipment and receiver • Connect the equipment  into an outlet on a circuit different from that to which the receiver is connected   • Consult Ingenico Support for help
 8  Contactless Payment  Expansion Module eN –Touch 1000 Installation Guide ! Changes or modifications not expressly approved by manufacturer could void the user’s authority to operate the equipment

Navigation menu